SSDs and RAID: What s the right strategy. Paul Goodwin VP Product Development Avant Technology
|
|
|
- Merryl Potter
- 10 years ago
- Views:
Transcription
1 SSDs and RAID: What s the right strategy Paul Goodwin VP Product Development Avant Technology
2 SSDs and RAID: What s the right strategy Flash Overview SSD Overview RAID overview Thoughts about Raid Strategies for SSDs
3 Flash Overview The smallest unit of NAND-based flash storage that can be written and subsequently read is a page. Today these pages are typically 4 KB in size. All bits in a blank page are set to 1s, and writing data to the page involves setting some of the bits within it to 0s. Individual bits within a page cannot be reset to 1s; rewriting the page to a different bit pattern requires an intermediate erase operation that resets all bits back to 1. Erasures are performed over large blocks (e.g., of 128 KB) spanning multiple pages. Blocks wear out as they are erased Exhibiting increasing BERs The PE cycle limit is the point where the BER becomes unmanageably high.
4 SSD Overview An SSD is comprised of a specialized processor with a I/O interface, typically SATA, on one side and a number of flash interfaces on the other.
5 The Function of the controller is to look like a Disk Drive. store and retrieve data to the flash devices connected to the back side of the controller. SSD Overview Additionally the controller has to manage the idiosyncrasies of the flash devices. In particular manage the PE cycle limitation of the flash devices. Wear leveling.
6 RAID Overview: Increasing performance of CPUs and memories will be squandered lf not matched by a similar performance increase in I/0. While the capacity of Single Large Expensive Disks (SLED) has grown rapidly, the performance improvement of SLED has been modest. Redundant Arrays of Inexpensive Disks (RAID), based on the magnetic disk technology developed for personal computers, offers an attractive alternative to SLED, promising improvements of an order of magnitude in performance, reliability, power consumption, and scalability. This paper introduces five levels of RAIDS - Patterson; A Case for Redundant Arrays of Inexpensive Disks (RAID) 1987
7 RAID Overview: Enter SSD Increasing performance of CPUs and memories will be squandered lf not matched by a similar performance increase in I/0. While the capacity of Single Large Expensive Disks (SLED) has grown rapidly, the performance improvement of SLED has been modest. Redundant Arrays of Inexpensive Disks (RAID), based on the magnetic disk technology developed for personal computers, offers an attractive alternative to SLED, promising improvements of an order of magnitude in performance, reliability, power consumption, and scalability. This paper introduces five levels of RAIDS Redundant Arrays Inexpensive Disks SSD are not really that really inexpensive SSD are not Disks New base to the acronym Redundant Array of Independent Drives
8 RAID Overview: Enter SSD Capacity HDs RAID Performance Increasing performance of CPUs and memories will be squandered lf not matched by a similar performance increase in I/0. While the capacity of Single Large Expensive Disks (SLED) has grown rapidly, the performance improvement of SLED has been modest. Redundant Arrays of Inexpensive Disks (RAID), based on the magnetic disk technology developed for personal computers, offers an attractive alternative to SLED, promising improvements of an order of magnitude in performance, reliability, power consumption, and scalability. This paper introduces five levels of RAIDS SSDs SLEDs
9 The advantages of RAID are not without cost Performance HD have only increased ~1.3X in speed over the past 10 years. SSDs can, on their own, approach the wire rate. Thru the RAID 0 component the SET can reach wire rate Reliability HDs have random, unpredictable failures SSDs have predictable and manageable failures RAID is good for random and unpredictable failures Power consumption HDs are power hungry SSDs are lower in power RAID has a power penalty for implementation Scalability HDs have a power and vibration problem when configuring large arrays SSDs scale well although are capacity challenged RAID has mechanical and power penalties RAID Overview: Increasing performance of CPUs and memories will be squandered lf not matched by a similar performance increase in I/0. While the capacity of Single Large Expensive Disks (SLED) has grown rapidly, the performance improvement of SLED has been modest. Redundant Arrays of Inexpensive Disks (RAID), based on the magnetic disk technology developed for personal computers, offers an attractive alternative to SLED, promising improvements of an order of magnitude in performance, reliability, power consumption, and scalability. This paper introduces five levels of RAIDS
10 Fairly large performance benefits RAID Overview: RAID 0 Not really RAID Data is split evenly across two or more disks with no parity or redundancy. For accesses that are larger than the stripe size the seek time of the array will be the same as that of a single drive. For accesses that are smaller than the stripe size allow the drives to seek independently. If the sectors accessed are spread evenly between the drives, the apparent seek time of the array will be half that of a single drive. The transfer speed of the array will be the transfer speed of all the disks added together, the speed of the RAID controller becomes the limiting factor. If you are going to have more than one drive you should set them up in a RAID 0 set.
11 RAID 0: Implementations RAID 0 may significantly increase the performance of an SSD Storage subsystem It s all a matter of where you place it An external RAID enclosure may not provide any performance benefit for SSDs SSDs running near SATA max won t benefit if connected via esata A Raid controller directly connected to the I/O will realize the benefits of RAID 0.
12 RAID 0: Implementations Storage subsystem on a card Density Form Factor IOPS Sequential or Random R/W RAID 40 GB to 4 TB PCIe, 8-lane Up to 240K Read/Write >2 GB/s 0, 1, 5, 6, 10, 50, 60
13 RAID Overview: RAID 1 Groups n + n disks as one virtual disk with the capacity of n disks. Data is replicated on the two disks. When a disk fails the data will be read from the failed mirror drive. read and write performance equal to a single drive Full Redundancy for protection of data. RAID 1 is more expensive in terms of disk space since twice the number of disks are used than required to store the data without redundancy.
14 Mirrored sets in a Striped configuration RAID Overview: RAID 10 Provides fault tolerance and improved performance. A1 B1 C1 A1 B1 C1 A2 B2 C2 A2 B2 C2 DISK 0 DISK 1 DISK 2 DISK 3
15 RAID Overview: RAID 5 provides data redundancy by using data striping in combination with parity across all physical drives in the set. Groups n disks as one large virtual disk with a capacity of (n-1) disks. Redundant information (parity) is alternately stored on all disks. When a disk fails, the virtual disk still works, but it is operating in a degraded state. The data is reconstructed from the surviving disks. Better read performance, but slower write performance. Redundancy for protection of data.
16 RAID 6 groups n disks as one large virtual disk with a capacity of (n-2) disks. RAID Overview: RAID 6 provides data redundancy by using data striping in combination with double distributed parity across all physical drives in the set. Parity information is alternately stored on all disks. The Raid 6 set remains functional with up to two disk failures. The data can be reconstructed from the surviving disks. Better read performance, but slower write performance. Increased redundancy for protection of data. Two disks per span are required for parity. RAID 6 is most expensive in terms of disk space.
17 RAID Overview: RAID 5 and RAID 6 RAID 5 and RAID 6 are expensive in terms of Flash operations Read the data block from drive Read the parity block from drive Compare the old data block with the write request. For each bit that has flipped in the data block, flip the corresponding bit in the parity block Write the updated data block Write the updated parity block
18 RAID Overview: RAID 50 Striping a RAID 5 drive set with a second RAID 5 Drive set. Groups n*s disks as one large virtual disk with a capacity of s*(n-1) disks, where s is the number of spans and n is the number of disks within each span. Redundant information (parity) is alternately stored on all disks of each RAID 5 span. Better read performance, but slower write performance. Requires proportionally as much parity information as standard RAID 5. Data is striped across all spans.
19 RAID Overview: RAID 60 Striping a RAID 6 drive set with a second RAID 6 drive set. Groups N disks as one large virtual disk with a capacity of S*(N-2) disks, where S is the number of sets and N is the number of disks within each span. Redundant information (parity) is alternately stored on all disks of each RAID 6 set. Better read performance, but slower write performance. Requires proportionally as much parity information as standard RAID 6. Data is striped across all spans.
20 Does RAID cause write amplification in SSDs? RAID and SSD: In Parity applications (RAID 5 and RAID 6) can writing a small block result in parity that affects multiple blocks? We are currently doing research on this to determine the effects of parity on SSD endurance. Some evidence is leaning towards supporting this. Some of this investigation is blind since we don t know the actual algorithms
21 RAID and SSD: SSDs don t eliminate the need for RAID Although less likely they can still have random failures For RAID using SSDs we prefer RAID 10 Because of the potential for RAID write amplification. Simple to implement RAID 10 is the fastest to rebuild Same cost as RAID 6 Faster that RAID 5 or RAID 6 RAID may help survive increased errors as the life cycle of a SSD is reached but swapping out drives is still necessary. Although they are likely to have been replaced by larger drives before that time is reached.
22 RAID and SSD: SSDs don t eliminate the need for RAID Although less likely they can still have random failures For RAID using SSDs we prefer RAID 10 Because of the potential for RAID write amplification. Simple to implement RAID 10 is the fastest to rebuild Same cost as RAID 6 Faster that RAID 5 or RAID 6 RAID may help survive increased errors as the life cycle of a SSD is reached but swapping out drives is still necessary. Although they are likely to have been replaced by larger drives before that time is reached.
23 RAID 10 vs. RAID 5 Tradeoff RAID 5 can t survive any 2 drive failures RAID 5's need to recalculate and redistribute parity data on a per-write basis. RAID 10 is faster to rebuild A1 B1 C1 A1 B1 C1 A2 B2 C2 DISK 0 DISK 1 DISK 2 A2 B2 C2 DISK 3
24 RAID 10 vs. RAID 6 Tradeoff RAID 6 can replace any 2 drive failures RAID 10 is faster to rebuild A1 B1 C1 A1 B1 C1 A2 B2 C2 A2 B2 C2 DISK 0 DISK 1 DISK 2 DISK 3
25 RAID 10 vs. RAID 50 Tradeoff RAID 50 only increases the speed of a RAID 5 based subsystem. SSDs are already faster. RAID 10 is faster to rebuild and doesn t suffer from any complexity A1 B1 C1 A1 B1 C1 A2 B2 C2 DISK 0 DISK 1 DISK 2 A2 B2 C2 DISK 3
26 RAID 10 vs. RAID 6 Tradeoff RAID 6 can replace any 2 drive failures RAID 10 is faster to rebuild A1 B1 C1 A1 B1 C1 A2 B2 C2 A2 B2 C2 DISK 0 DISK 1 DISK 2 DISK 3
27 RAID Strategies for SSDs: Next Steps More investigation A lot more data needs to be collected SSD specific RAID controllers Do we need new RAID controllers that work with SSDs? To be continued
High-Performance SSD-Based RAID Storage. Madhukar Gunjan Chakhaiyar Product Test Architect
High-Performance SSD-Based RAID Storage Madhukar Gunjan Chakhaiyar Product Test Architect 1 Agenda HDD based RAID Performance-HDD based RAID Storage Dynamics driving to SSD based RAID Storage Evolution
Sistemas Operativos: Input/Output Disks
Sistemas Operativos: Input/Output Disks Pedro F. Souto ([email protected]) April 28, 2012 Topics Magnetic Disks RAID Solid State Disks Topics Magnetic Disks RAID Solid State Disks Magnetic Disk Construction
Disks and RAID. Profs. Bracy and Van Renesse. based on slides by Prof. Sirer
Disks and RAID Profs. Bracy and Van Renesse based on slides by Prof. Sirer 50 Years Old! 13th September 1956 The IBM RAMAC 350 Stored less than 5 MByte Reading from a Disk Must specify: cylinder # (distance
DELL RAID PRIMER DELL PERC RAID CONTROLLERS. Joe H. Trickey III. Dell Storage RAID Product Marketing. John Seward. Dell Storage RAID Engineering
DELL RAID PRIMER DELL PERC RAID CONTROLLERS Joe H. Trickey III Dell Storage RAID Product Marketing John Seward Dell Storage RAID Engineering http://www.dell.com/content/topics/topic.aspx/global/products/pvaul/top
RAID Overview: Identifying What RAID Levels Best Meet Customer Needs. Diamond Series RAID Storage Array
ATTO Technology, Inc. Corporate Headquarters 155 Crosspoint Parkway Amherst, NY 14068 Phone: 716-691-1999 Fax: 716-691-9353 www.attotech.com [email protected] RAID Overview: Identifying What RAID Levels
VERY IMPORTANT NOTE! - RAID
Disk drives are an integral part of any computing system. Disk drives are usually where the operating system and all of an enterprise or individual s data are stored. They are also one of the weakest links
Using RAID6 for Advanced Data Protection
Using RAI6 for Advanced ata Protection 2006 Infortrend Corporation. All rights reserved. Table of Contents The Challenge of Fault Tolerance... 3 A Compelling Technology: RAI6... 3 Parity... 4 Why Use RAI6...
RAID Basics Training Guide
RAID Basics Training Guide Discover a Higher Level of Performance RAID matters. Rely on Intel RAID. Table of Contents 1. What is RAID? 2. RAID Levels RAID 0 RAID 1 RAID 5 RAID 6 RAID 10 RAID 0+1 RAID 1E
Lecture 36: Chapter 6
Lecture 36: Chapter 6 Today s topic RAID 1 RAID Redundant Array of Inexpensive (Independent) Disks Use multiple smaller disks (c.f. one large disk) Parallelism improves performance Plus extra disk(s) for
HP Smart Array Controllers and basic RAID performance factors
Technical white paper HP Smart Array Controllers and basic RAID performance factors Technology brief Table of contents Abstract 2 Benefits of drive arrays 2 Factors that affect performance 2 HP Smart Array
PIONEER RESEARCH & DEVELOPMENT GROUP
SURVEY ON RAID Aishwarya Airen 1, Aarsh Pandit 2, Anshul Sogani 3 1,2,3 A.I.T.R, Indore. Abstract RAID stands for Redundant Array of Independent Disk that is a concept which provides an efficient way for
RAID. RAID 0 No redundancy ( AID?) Just stripe data over multiple disks But it does improve performance. Chapter 6 Storage and Other I/O Topics 29
RAID Redundant Array of Inexpensive (Independent) Disks Use multiple smaller disks (c.f. one large disk) Parallelism improves performance Plus extra disk(s) for redundant data storage Provides fault tolerant
An Introduction to RAID. Giovanni Stracquadanio [email protected] www.dmi.unict.it/~stracquadanio
An Introduction to RAID Giovanni Stracquadanio [email protected] www.dmi.unict.it/~stracquadanio Outline A definition of RAID An ensemble of RAIDs JBOD RAID 0...5 Configuring and testing a Linux
Reliability and Fault Tolerance in Storage
Reliability and Fault Tolerance in Storage Dalit Naor/ Dima Sotnikov IBM Haifa Research Storage Systems 1 Advanced Topics on Storage Systems - Spring 2014, Tel-Aviv University http://www.eng.tau.ac.il/semcom
RAID HARDWARE. On board SATA RAID controller. RAID drive caddy (hot swappable) SATA RAID controller card. Anne Watson 1
RAID HARDWARE On board SATA RAID controller SATA RAID controller card RAID drive caddy (hot swappable) Anne Watson 1 RAID The word redundant means an unnecessary repetition. The word array means a lineup.
Chapter 6. 6.1 Introduction. Storage and Other I/O Topics. p. 570( 頁 585) Fig. 6.1. I/O devices can be characterized by. I/O bus connections
Chapter 6 Storage and Other I/O Topics 6.1 Introduction I/O devices can be characterized by Behavior: input, output, storage Partner: human or machine Data rate: bytes/sec, transfers/sec I/O bus connections
How To Create A Multi Disk Raid
Click on the diagram to see RAID 0 in action RAID Level 0 requires a minimum of 2 drives to implement RAID 0 implements a striped disk array, the data is broken down into blocks and each block is written
XtremIO DATA PROTECTION (XDP)
White Paper XtremIO DATA PROTECTION (XDP) Flash-Specific Data Protection, Provided by XtremIO (Ver..0) Abstract This white paper introduces the and discusses its benefits and advantages over RAID, with
CS420: Operating Systems
NK YORK COLLEGE OF PENNSYLVANIA HG OK 2 RAID YORK COLLEGE OF PENNSYLVAN James Moscola Department of Physical Sciences York College of Pennsylvania Based on Operating System Concepts, 9th Edition by Silberschatz,
RAID 5 rebuild performance in ProLiant
RAID 5 rebuild performance in ProLiant technology brief Abstract... 2 Overview of the RAID 5 rebuild process... 2 Estimating the mean-time-to-failure (MTTF)... 3 Factors affecting RAID 5 array rebuild
Definition of RAID Levels
RAID The basic idea of RAID (Redundant Array of Independent Disks) is to combine multiple inexpensive disk drives into an array of disk drives to obtain performance, capacity and reliability that exceeds
RAID: Redundant Arrays of Independent Disks
RAID: Redundant Arrays of Independent Disks Dependable Systems Dr.-Ing. Jan Richling Kommunikations- und Betriebssysteme TU Berlin Winter 2012/2013 RAID: Introduction Redundant array of inexpensive disks
technology brief RAID Levels March 1997 Introduction Characteristics of RAID Levels
technology brief RAID Levels March 1997 Introduction RAID is an acronym for Redundant Array of Independent Disks (originally Redundant Array of Inexpensive Disks) coined in a 1987 University of California
Price/performance Modern Memory Hierarchy
Lecture 21: Storage Administration Take QUIZ 15 over P&H 6.1-4, 6.8-9 before 11:59pm today Project: Cache Simulator, Due April 29, 2010 NEW OFFICE HOUR TIME: Tuesday 1-2, McKinley Last Time Exam discussion
Q & A From Hitachi Data Systems WebTech Presentation:
Q & A From Hitachi Data Systems WebTech Presentation: RAID Concepts 1. Is the chunk size the same for all Hitachi Data Systems storage systems, i.e., Adaptable Modular Systems, Network Storage Controller,
The Pitfalls of Deploying Solid-State Drive RAIDs
The Pitfalls of Deploying Solid-State Drive RAIDs Nikolaus Jeremic 1, Gero Mühl 1, Anselm Busse 2 and Jan Richling 2 Architecture of Application Systems Group 1 Faculty of Computer Science and Electrical
CS161: Operating Systems
CS161: Operating Systems Matt Welsh [email protected] Lecture 18: RAID April 19, 2007 2007 Matt Welsh Harvard University 1 RAID Redundant Arrays of Inexpensive Disks Invented in 1986-1987 by David Patterson
NAND Flash Media Management Through RAIN
Flash Media Management Through RAIN Scott Shadley, Senior roduct Marketing Manager Micron Technology, Inc. Technical Marketing Brief What Is RAIN, and Why Do SSDs Need It? This brief compares redundant
How to choose the right RAID for your Dedicated Server
Overview of RAID Let's first address, "What is RAID and what does RAID stand for?" RAID, an acronym for "Redundant Array of Independent Disks, is a storage technology that links or combines multiple hard
Assessing RAID ADG vs. RAID 5 vs. RAID 1+0
White Paper October 2001 Prepared by Industry Standard Storage Group Compaq Computer Corporation Contents Overview...3 Defining RAID levels...3 Evaluating RAID levels...3 Choosing a RAID level...4 Assessing
RAID Levels and Components Explained Page 1 of 23
RAID Levels and Components Explained Page 1 of 23 What's RAID? The purpose of this document is to explain the many forms or RAID systems, and why they are useful, and their disadvantages. RAID - Redundant
Storage node capacity in RAID0 is equal to the sum total capacity of all disks in the storage node.
RAID configurations defined 1/7 Storage Configuration: Disk RAID and Disk Management > RAID configurations defined Next RAID configurations defined The RAID configuration you choose depends upon how you
Operating Systems. RAID Redundant Array of Independent Disks. Submitted by Ankur Niyogi 2003EE20367
Operating Systems RAID Redundant Array of Independent Disks Submitted by Ankur Niyogi 2003EE20367 YOUR DATA IS LOST@#!! Do we have backups of all our data???? - The stuff we cannot afford to lose?? How
Firebird and RAID. Choosing the right RAID configuration for Firebird. Paul Reeves IBPhoenix. mail: [email protected]
Firebird and RAID Choosing the right RAID configuration for Firebird. Paul Reeves IBPhoenix mail: [email protected] Introduction Disc drives have become so cheap that implementing RAID for a firebird
Cloud Storage. Parallels. Performance Benchmark Results. White Paper. www.parallels.com
Parallels Cloud Storage White Paper Performance Benchmark Results www.parallels.com Table of Contents Executive Summary... 3 Architecture Overview... 3 Key Features... 4 No Special Hardware Requirements...
GENERAL INFORMATION COPYRIGHT... 3 NOTICES... 3 XD5 PRECAUTIONS... 3 INTRODUCTION... 4 FEATURES... 4 SYSTEM REQUIREMENT... 4
1 Table of Contents GENERAL INFORMATION COPYRIGHT... 3 NOTICES... 3 XD5 PRECAUTIONS... 3 INTRODUCTION... 4 FEATURES... 4 SYSTEM REQUIREMENT... 4 XD5 FAMILULARIZATION... 5 PACKAGE CONTENTS... 5 HARDWARE
Flash Memory Arrays Enabling the Virtualized Data Center. July 2010
Flash Memory Arrays Enabling the Virtualized Data Center July 2010 2 Flash Memory Arrays Enabling the Virtualized Data Center This White Paper describes a new product category, the flash Memory Array,
PowerVault MD1200/MD1220 Storage Solution Guide for Applications
PowerVault MD200/MD220 Storage Solution Guide for Applications A Dell Technical White Paper Dell PowerVault Storage Systems Joe Noyola Systems Performance Analysis Group Chuck Colburn Storage Advanced
Storing Data: Disks and Files
Storing Data: Disks and Files (From Chapter 9 of textbook) Storing and Retrieving Data Database Management Systems need to: Store large volumes of data Store data reliably (so that data is not lost!) Retrieve
RAID Level Descriptions. RAID 0 (Striping)
RAID Level Descriptions RAID 0 (Striping) Offers low cost and maximum performance, but offers no fault tolerance; a single disk failure results in TOTAL data loss. Businesses use RAID 0 mainly for tasks
Configuring ThinkServer RAID 500 and RAID 700 Adapters. Lenovo ThinkServer
Configuring ThinkServer RAID 500 and RAID 700 Adapters Lenovo ThinkServer October 4, 2011 Contents Overview... 4 RAID 500 features... 4 RAID 700 features... 4 RAID Overview... 4 Choosing the RAID Level...
Flash 101. Violin Memory Switzerland. Violin Memory Inc. Proprietary 1
Flash 101 Violin Memory Switzerland Violin Memory Inc. Proprietary 1 Agenda - What is Flash? - What is the difference between Flash types? - Why are SSD solutions different from Flash Storage Arrays? -
File System & Device Drive. Overview of Mass Storage Structure. Moving head Disk Mechanism. HDD Pictures 11/13/2014. CS341: Operating System
CS341: Operating System Lect 36: 1 st Nov 2014 Dr. A. Sahu Dept of Comp. Sc. & Engg. Indian Institute of Technology Guwahati File System & Device Drive Mass Storage Disk Structure Disk Arm Scheduling RAID
Chapter 6 External Memory. Dr. Mohamed H. Al-Meer
Chapter 6 External Memory Dr. Mohamed H. Al-Meer 6.1 Magnetic Disks Types of External Memory Magnetic Disks RAID Removable Optical CD ROM CD Recordable CD-R CD Re writable CD-RW DVD Magnetic Tape 2 Introduction
Outline. Database Management and Tuning. Overview. Hardware Tuning. Johann Gamper. Unit 12
Outline Database Management and Tuning Hardware Tuning Johann Gamper 1 Free University of Bozen-Bolzano Faculty of Computer Science IDSE Unit 12 2 3 Conclusion Acknowledgements: The slides are provided
Distribution One Server Requirements
Distribution One Server Requirements Introduction Welcome to the Hardware Configuration Guide. The goal of this guide is to provide a practical approach to sizing your Distribution One application and
RAID Implementation for StorSimple Storage Management Appliance
RAID Implementation for StorSimple Storage Management Appliance Alpa Kohli June, 2012 KB-00008 Document Revision 1 StorSimple knowledge base articles are intended to provide customers with the information
How To Use A Raid
www.gateway.com About RAID About RAID RAID (Redundant Array of Inexpensive/Independent Disks) lets your computer use multiple hard drives more efficiently. Your computer supports RAID 0, RAID 1, RAID 5,
Accelerating I/O- Intensive Applications in IT Infrastructure with Innodisk FlexiArray Flash Appliance. Alex Ho, Product Manager Innodisk Corporation
Accelerating I/O- Intensive Applications in IT Infrastructure with Innodisk FlexiArray Flash Appliance Alex Ho, Product Manager Innodisk Corporation Outline Innodisk Introduction Industry Trend & Challenge
RAID Made Easy By Jon L. Jacobi, PCWorld
9916 Brooklet Drive Houston, Texas 77099 Phone 832-327-0316 www.safinatechnolgies.com RAID Made Easy By Jon L. Jacobi, PCWorld What is RAID, why do you need it, and what are all those mode numbers that
SSDs tend to be more rugged than hard drives with respect to shock and vibration because SSDs have no moving parts.
Overview Introduction Solid State Drives (SSDs) are fast becoming a real force with respect to storage in the computer industry. With no moving parts, storage is no longer bound by mechanical barriers
All-Flash Storage Solution for SAP HANA:
All-Flash Storage Solution for SAP HANA: Storage Considerations using SanDisk Solid State Devices WHITE PAPER 951 SanDisk Drive, Milpitas, CA 95035 www.sandisk.com Table of Contents Preface 3 Why SanDisk?
CS 6290 I/O and Storage. Milos Prvulovic
CS 6290 I/O and Storage Milos Prvulovic Storage Systems I/O performance (bandwidth, latency) Bandwidth improving, but not as fast as CPU Latency improving very slowly Consequently, by Amdahl s Law: fraction
OBJECTIVE ANALYSIS WHITE PAPER MATCH FLASH. TO THE PROCESSOR Why Multithreading Requires Parallelized Flash ATCHING
OBJECTIVE ANALYSIS WHITE PAPER MATCH ATCHING FLASH TO THE PROCESSOR Why Multithreading Requires Parallelized Flash T he computing community is at an important juncture: flash memory is now generally accepted
Chapter 10: Mass-Storage Systems
Chapter 10: Mass-Storage Systems Physical structure of secondary storage devices and its effects on the uses of the devices Performance characteristics of mass-storage devices Disk scheduling algorithms
Differential RAID: Rethinking RAID for SSD Reliability
Differential RAID: Rethinking RAID for SSD Reliability ABSTRACT Asim Kadav University of Wisconsin Madison, WI [email protected] Vijayan Prabhakaran [email protected] Deployment of SSDs in enterprise
Technologies Supporting Evolution of SSDs
Technologies Supporting Evolution of SSDs By TSUCHIYA Kenji Notebook PCs equipped with solid-state drives (SSDs), featuring shock and vibration durability due to the lack of moving parts, appeared on the
TECHNOLOGY BRIEF. Compaq RAID on a Chip Technology EXECUTIVE SUMMARY CONTENTS
TECHNOLOGY BRIEF August 1999 Compaq Computer Corporation Prepared by ISSD Technology Communications CONTENTS Executive Summary 1 Introduction 3 Subsystem Technology 3 Processor 3 SCSI Chip4 PCI Bridge
Performance Beyond PCI Express: Moving Storage to The Memory Bus A Technical Whitepaper
: Moving Storage to The Memory Bus A Technical Whitepaper By Stephen Foskett April 2014 2 Introduction In the quest to eliminate bottlenecks and improve system performance, the state of the art has continually
Disk Storage & Dependability
Disk Storage & Dependability Computer Organization Architectures for Embedded Computing Wednesday 19 November 14 Many slides adapted from: Computer Organization and Design, Patterson & Hennessy 4th Edition,
EMC XTREMIO EXECUTIVE OVERVIEW
EMC XTREMIO EXECUTIVE OVERVIEW COMPANY BACKGROUND XtremIO develops enterprise data storage systems based completely on random access media such as flash solid-state drives (SSDs). By leveraging the underlying
Redundant Array of Independent Disks (RAID)
For Data Centers Redundant Array of Independent Disks (RAID) Combine and control multiple storage devices for better performance and reliability Application note 2014 Samsung Electronics Co. 1. What is?
SSD Performance Tips: Avoid The Write Cliff
ebook 100% KBs/sec 12% GBs Written SSD Performance Tips: Avoid The Write Cliff An Inexpensive and Highly Effective Method to Keep SSD Performance at 100% Through Content Locality Caching Share this ebook
Intel RAID SSD Cache Controller RCS25ZB040
SOLUTION Brief Intel RAID SSD Cache Controller RCS25ZB040 When Faster Matters Cost-Effective Intelligent RAID with Embedded High Performance Flash Intel RAID SSD Cache Controller RCS25ZB040 When Faster
Automated Data-Aware Tiering
Automated Data-Aware Tiering White Paper Drobo s revolutionary new breakthrough technology automates the provisioning, deployment, and performance acceleration for a fast tier of SSD storage in the Drobo
The What, Why and How of the Pure Storage Enterprise Flash Array
The What, Why and How of the Pure Storage Enterprise Flash Array Ethan L. Miller (and a cast of dozens at Pure Storage) What is an enterprise storage array? Enterprise storage array: store data blocks
Striped Set, Advantages and Disadvantages of Using RAID
Algorithms and Methods for Distributed Storage Networks 4: Volume Manager and RAID Institut für Informatik Wintersemester 2007/08 RAID Redundant Array of Independent Disks Patterson, Gibson, Katz, A Case
Dell PowerEdge RAID Controller Cards H700 and H800 Technical Guide
PowerEdge RAID Controller Cards H700 and H800 Technical Guide Enterprise-class controllers designed for performance, reliability, and fault tolerance. This document is for informational purposes only.
Input / Ouput devices. I/O Chapter 8. Goals & Constraints. Measures of Performance. Anatomy of a Disk Drive. Introduction - 8.1
Introduction - 8.1 I/O Chapter 8 Disk Storage and Dependability 8.2 Buses and other connectors 8.4 I/O performance measures 8.6 Input / Ouput devices keyboard, mouse, printer, game controllers, hard drive,
SSD Server Hard Drives for IBM
New for 2011! Axiom is introducing a new line of SSD Hot-Swap Server Hard Drives. Our high performance SSD hard drives have been paired with system specific Hot-Swap trays to deliver seamless integration
Overview of I/O Performance and RAID in an RDBMS Environment. By: Edward Whalen Performance Tuning Corporation
Overview of I/O Performance and RAID in an RDBMS Environment By: Edward Whalen Performance Tuning Corporation Abstract This paper covers the fundamentals of I/O topics and an overview of RAID levels commonly
MaxDeploy Ready. Hyper- Converged Virtualization Solution. With SanDisk Fusion iomemory products
MaxDeploy Ready Hyper- Converged Virtualization Solution With SanDisk Fusion iomemory products MaxDeploy Ready products are configured and tested for support with Maxta software- defined storage and with
Systems Infrastructure for Data Science. Web Science Group Uni Freiburg WS 2014/15
Systems Infrastructure for Data Science Web Science Group Uni Freiburg WS 2014/15 Lecture I: Storage Storage Part I of this course Uni Freiburg, WS 2014/15 Systems Infrastructure for Data Science 3 The
Flash for Databases. September 22, 2015 Peter Zaitsev Percona
Flash for Databases September 22, 2015 Peter Zaitsev Percona In this Presentation Flash technology overview Review some of the available technology What does this mean for databases? Specific opportunities
SOLID STATE DRIVES AND PARALLEL STORAGE
SOLID STATE DRIVES AND PARALLEL STORAGE White paper JANUARY 2013 1.888.PANASAS www.panasas.com Overview Solid State Drives (SSDs) have been touted for some time as a disruptive technology in the storage
DELL SOLID STATE DISK (SSD) DRIVES
DELL SOLID STATE DISK (SSD) DRIVES STORAGE SOLUTIONS FOR SELECT POWEREDGE SERVERS By Bryan Martin, Dell Product Marketing Manager for HDD & SSD delltechcenter.com TAB LE OF CONTENTS INTRODUCTION 3 DOWNFALLS
Deploying and Optimizing SQL Server for Virtual Machines
Deploying and Optimizing SQL Server for Virtual Machines Deploying and Optimizing SQL Server for Virtual Machines Much has been written over the years regarding best practices for deploying Microsoft SQL
Impact of Stripe Unit Size on Performance and Endurance of SSD-Based RAID Arrays
1 Impact of Stripe Unit Size on Performance and Endurance of SSD-Based RAID Arrays Farzaneh Rajaei Salmasi Hossein Asadi Majid GhasemiGol [email protected] [email protected] [email protected]
What is RAID and how does it work?
What is RAID and how does it work? What is RAID? RAID is the acronym for either redundant array of inexpensive disks or redundant array of independent disks. When first conceived at UC Berkley the former
Storage Technologies for Video Surveillance
The surveillance industry continues to transition from analog to digital. This transition is taking place on two fronts how the images are captured and how they are stored. The way surveillance images
The Pros and Cons of Erasure Coding & Replication vs. RAID in Next-Gen Storage Platforms. Abhijith Shenoy Engineer, Hedvig Inc.
The Pros and Cons of Erasure Coding & Replication vs. RAID in Next-Gen Storage Platforms Abhijith Shenoy Engineer, Hedvig Inc. @hedviginc The need for new architectures Business innovation Time-to-market
VMware Virtual SAN 6.0 Design and Sizing Guide
Virtual SAN Design and Sizing Guide VMware Virtual SAN 6.0 Design and Sizing Guide Cormac Hogan Storage and Availability Business Unit VMware v 1.0.5/April 2015 V M w a r e S t o r a g e a n d A v a i
PARALLELS CLOUD STORAGE
PARALLELS CLOUD STORAGE Performance Benchmark Results 1 Table of Contents Executive Summary... Error! Bookmark not defined. Architecture Overview... 3 Key Features... 5 No Special Hardware Requirements...
Solid State Drive Technology
Technical white paper Solid State Drive Technology Differences between SLC, MLC and TLC NAND Table of contents Executive summary... 2 SLC vs MLC vs TLC... 2 NAND cell technology... 2 Write amplification...
The Technologies & Architectures. President, Demartek
Deep Dive on Solid State t Storage The Technologies & Architectures Dennis Martin Dennis Martin President, Demartek Demartek Company Overview Industry analysis with on-site test lab Lab includes servers,
Real-Time Storage Tiering for Real-World Workloads
Real-Time Storage Tiering for Real-World Workloads Dot Hill Systems Introduction 1 INTRODUCTION The performance of many of today s server-based applications is limited by the relatively slow input and
Technology Update White Paper. High Speed RAID 6. Powered by Custom ASIC Parity Chips
Technology Update White Paper High Speed RAID 6 Powered by Custom ASIC Parity Chips High Speed RAID 6 Powered by Custom ASIC Parity Chips Why High Speed RAID 6? Winchester Systems has developed High Speed
IncidentMonitor Server Specification Datasheet
IncidentMonitor Server Specification Datasheet Prepared by Monitor 24-7 Inc October 1, 2015 Contact details: [email protected] North America: +1 416 410.2716 / +1 866 364.2757 Europe: +31 088 008.4600
FUSION iocontrol HYBRID STORAGE ARCHITECTURE 1 WWW.FUSIONIO.COM
1 WWW.FUSIONIO.COM FUSION iocontrol HYBRID STORAGE ARCHITECTURE Contents Contents... 2 1 The Storage I/O and Management Gap... 3 2 Closing the Gap with Fusion-io... 4 2.1 Flash storage, the Right Way...
The Shortcut Guide to Balancing Storage Costs and Performance with Hybrid Storage
The Shortcut Guide to Balancing Storage Costs and Performance with Hybrid Storage sponsored by Dan Sullivan Chapter 1: Advantages of Hybrid Storage... 1 Overview of Flash Deployment in Hybrid Storage Systems...
NVIDIA RAID Installation Guide
NVIDIA RAID Installation Guide 1. NVIDIA BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID. 2 1.2 RAID Configurations Precautions.. 3 1.3 Create Disk Array. 4 2. NVIDIA Windows RAID Installation
SSDs tend to be more rugged than hard drives with respect to shock and vibration because SSDs have no moving parts.
Introduction Solid State Drives (SSDs) are fast becoming a real force with respect to storage in the computer industry. With no moving parts, storage is no longer bound by mechanical barriers to higher
UK HQ RAID Chunk Size T F www.xyratex.com ISO 14001
RAID Chunk Size Notices The information in this document is subject to change without notice. While every effort has been made to ensure that all information in this document is accurate, Xyratex accepts
An Introduction to RAID 6 ULTAMUS TM RAID
An Introduction to RAID 6 ULTAMUS TM RAID The highly attractive cost per GB of SATA storage capacity is causing RAID products based on the technology to grow in popularity. SATA RAID is now being used
Understanding endurance and performance characteristics of HP solid state drives
Understanding endurance and performance characteristics of HP solid state drives Technology brief Introduction... 2 SSD endurance... 2 An introduction to endurance... 2 NAND organization... 2 SLC versus
The Effect of Priorities on LUN Management Operations
Abstract This white paper describes the effect of each of the four Priorities (ASAP, High, Medium, and Low) on overall EMC CLARiiON performance in executing. The LUN Management Operations are migrate,
Solid State Technology What s New?
Solid State Technology What s New? Dennis Martin, President, Demartek www.storagedecisions.com Agenda: Solid State Technology What s New? Demartek About Us Solid-state storage overview Types of NAND flash