Factors rebuilding a degraded RAID
|
|
|
- Francine Lucy Morgan
- 10 years ago
- Views:
Transcription
1 Whitepaper Abstract This whitepaper introduces the procedure rebuilding a degraded RAID. You will find information about RAID levels and their rebuild procedures; rebuild time and its dependent factors. You will get estimation hints to calculate the rebuild time. This whitepaper implies general knowledge about storage systems, storage system architecture and RAID technology. 1
2 Table of Content PRODUCT FAMILIES COVERED BY THIS DOCUMENT... 3 WHAT HAPPENS IF ONE OR MORE DISKS IN A RAID ARRAY FAIL? DISK FAILURE IN A RAID 1 OR RAID DISK FAILURE IN A RAID 3 OR RAID 3+0 (DEDICATED PARITY RAID) DISK FAILURE IN A RAID 5 OR RAID 6 (DISTRIBUTED PARITY RAID) DISK FAILURE IN A RAID 5 WITH HOT-SPARE DISK THE KEY FACTORS INFLUENCING THE REBUILD TIME THE COMPUTING POWER OF THE RAID CONTROLLER The computing power bottleneck Recommended configurations for EonStor DS G6 and G7 storage systems THE WRITE PERFORMANCE OF A SINGLE DRIVE IN A RAID ARRAY NL-SAS vs. SATA III hard drive SATA vs. SATA III hard drive with Native Command Queuing (NCQ) enabled The drive bottleneck THE CAPACITY OF A FAILED HARD DRIVE ESTIMATING THE REBUILD TIME REBUILD TIME, IF COMPUTING POWER IS THE BOTTLENECK REBUILD TIME, IF WRITE THROUGHPUT IS THE BOTTLENECK APPENDIX: INFORTREND WEB LINKS DRIVE VENDOR LINKS
3 1. Product families covered by this document This document applies to the following Infortrend storage system families: EonStor DS G6 Family EonStor DS G7 Family For more information regarding individual product models, please visit 3
4 2. Factors rebuilding a degraded RAID What happens if one or more disks in a RAID array fail? Single disks or single level striped arrays will lose all data in case of a disk failure. You have to replace the failed disk and then restore the lost data from a backup before you can continue operation. Opting for a mirrored (RAID 1 and RAID 1+0) or parity array (RAID 5 / 6 and RAID 5+0 / 6+0); despite lower performance and higher TCA / TCO can solve this problem. There is an extremely small chance that 2 disks Figure 1: RAID 0, disk failure fail simultaneously, but if data protection and integrity are highest priority and cost and performance minor, consider using a RAID 6 or RAID 6+0 to be prepared for that eventuality. 2.1 Disk failure in a RAID 1 or RAID 1+0 The failed disk has to be replaced by a new disk first. The RAID controller will write then all data on the mirror to the newly installed disk (Rebuild), to be considered as a disk copy from the mirror to the new disk. There is no need to restore a previous made back-up, with possible outdated data. The RAID controller is copying the data in the background, so operation will be continued. Figure 2: RAID 1, disk failure 4
5 2.2 Disk failure in a RAID 3 or RAID 3+0 (Dedicated Parity RAID) If one disk fails, the data can be rebuild by reading all remaining disks (all but the failed one) and writing the rebuilt data to the newly replaced disk. Writing to the newly replaced single disk is enough to rebuild the array. There are actually two factors that can impact the rebuild of a degraded RAID (A RAID will be degraded, if one or more disks fail). If the dedicated parity disk fails, the rebuilding process is a matter of recalculating the parity info by reading all remaining data and writing the parity to the new dedicated disk. If a data disk fails, the data need to be rebuild, based on the remaining data and the parity. This is the most time-consuming part of rebuilding a degraded RAID. Figure 3: RAID 3, disk failure 2.3 Disk failure in a RAID 5 or RAID 6 (Distributed Parity RAID) If a disk fails, the data can be rebuild by reading all remaining disks, rebuilding the data, recalculating the parity information and writing the data and parity information to the new disk. This is time-consuming. The rebuild time is related to drive capacity and number of drives in the RAID array or RAID sub-arrays (RAID 5+0 or RAID 6+0), further to the computing power of the controller. Figure 4: RAID 5, disk failure 5
6 2.4 Disk failure in a RAID 5 with hot-spare disk When an RAID array is not protected by a hot spare disk, the failed disk has to be removed and replaced by a new one. The controller will detect the new disk and start rebuilding the RAID array. Using a hot-spare disk will overcome the replacement procedure. In case of disk failure a hot spare disk is automatically incorporated into the RAID array and takes over the failed disk. Figure 5: RAID 5 + Hot-Spare, disk failure 3. The key factors influencing the rebuild time There are 3 main factors that affect the duration of rebuild time: The computing power of the RAID controller The write performance of a drive in a RAID array The capacity of the failed drive 3.1 The computing power of the RAID controller The computing power of a RAID controller is the maximum throughput per second that can be run in XOR. As shown in the table below, EonStor DS G7 storage systems reduce the rebuild time to 62% of the rebuild time of an EonStor DS G6 storage system in a RAID 5 configuration with 15 hard drives. Model Computing power Disk Write Performance (*1) Configuration (RAID 5) Rebuild time Time saving in % G6 G7 850 MB/s 1350 MB/s NL SAS Toshiba 1TB (122 MB/s) 7 HDDs 2 hr. 35 min. 15 HDDs 4 hr. 54 min. 7 HDDs 2 hr. 35 min. Table 1: Computing power of the RAID controller 15 HDDs 3 hr. 5 min. 38% 6
7 3.1.1 The computing power bottleneck The computing power of a RAID controller is limited (see Table 1). The work load of the RAID controller will increase as more drives will be added to a RAID array / RAID sub-array. The rebuild time will increase significant too then. Example: 1. Configuration: EonStor DS G6 computing power = 850 Mbps EonStor DS G7 computing power = 1350 Mbps RAID 5 array = 6 x SAS 6G 400 GB SSD w/ MB/s max. seq. WRITE throughput 2. Calculation: Max. total READ throughput = (drive # - failed drive #) * Max. WRITE throughput Max. total READ throughput = (6-1)* MB/s = MB/s Computing power Total READ throughput (in rebuild process) 3. Result: EonStor DS G6: 850 Mbps < MB/s Computing power = Bottleneck EonStor DS G7: 1350 Mbps > MB/s Recommended configurations for EonStor DS G6 and G7 storage systems 1. EonStor DS G6: Figure 6: ESDS G6 Number of HDD recommendation We recommend using less or equal 8 hard drives in a RAID array / sub-array for a suitable rebuild time. If you want to use more than 8 hard drives in a RAID 5 or RAID 6, we recommend using RAID 5+0 or RAID 6+0 and balance the hard drive number among the RAID sub-arrays ( 8 hard drives per RAID sub-array). 7
8 2. EonStor DS G7: Figure 7: ESDS G7 Number of HDD recommendation A suitable rebuild time will be achieved using equal or less than 16 hard drives in a RAID array or a RAID sub-array. If you want to use a RAID 5 with more than 10 hard drives, we recommend using RAID 5+0. Even the difference of rebuild time using 10 or 16 hard drives is quite small; we suggest using less than 10 drives in a RAID 5 array or RAID 5+0 sub-array to minimize the risk of a 2 nd hard drive failure. Using RAID 6, we recommend using less or equal 16 hard drives as the RAID protects against 2 drive failures. Consider using RAID 6+0 when using more than 16 hard drives. 3.2 The write performance of a single drive in a RAID array The maximum write performance of a single drive in the RAID array is the maximum throughput per second written to the Hot-Spare disk NL-SAS vs. SATA III hard drive The table below displays the time saving using the same EonStor DS G7 storage system in RAID 5, once with NL- SAS hard drives and once with SATA III hard drives. Using NL-SAS hard drives will reduce the rebuild time to 43% of the time using SATA III hard drives. Model G7 Computing power 1350 MB/s Write performance (*1) SATA Hitachi 2TB (43 MB/s w/o NCQ) NL SAS Toshiba 2TB (122 MB/s) Configuration (RAID 5) Rebuild time 7 HDDs 13 hrs 30 mins Table 2: Write performance of NL-SAS vs. SATA hard drive Time saving in % 7 HDDs 5 hrs 50 mins 57% (*1) The used WRITE throughput is the result of performance tests. Vendor numbers might not match reality! 8
9 3.2.2 SATA vs. SATA III hard drive with Native Command Queuing (NCQ) enabled A RAID controller that supports Native Command Queuing (NCQ) for SATA hard drives is able to reduce the rebuild time significant compared to a RAID controller that is not supporting NCQ. The table shows an EonStor DS G6 storage system without NCQ support compared to an EonStor DS G7 storage system with NCQ enabled. The computing power in this case is not relevant, as the rebuild time using 7 hard drives is the same on EonStor DS G6 and G7 (see 3.1). Model Computing power Write performance (*1) Configuration (Raid 5) Rebuild time Time saving in % G6 850 MB/s SATA Hitachi 2TB (43 MB/s w/o NCQ) 7 HDDs 13 hrs 30 mins G MB/s SATA Hitachi 2TB (130 MB/s w/ NCQ) 7 HDDs 4 hrs 54 mins 64% Table 3: Write performance of SATA hard drive w/o NCQ vs. w/ NCQ The drive bottleneck In general the maximum READ throughput of a single hard drive is higher than the max. WRITE throughput. NL SAS Max. Seq. Read Throughput Max. Seq. Write Throughput (*1) Toshiba 1TB MK1001TRKB 147 MB/s 122 MB/s Table 4: READ throughput vs. WRITE throughput In Rebuild process the write throughput is equal to the read throughput. If one data is read from a single disk per second, one data is written to the Hot-Spare disk per second. If two data are read from a single disk per second, two data are written to the Hot-Spare disk per second. Example: 1. Configuration: A.) EonStor DS G7 w/ 7 x NL-SAS 6G HDD (1TB), max. seq. WRITE throughput 122 MB/s B.) EonStor DS G7 w/ 7 x SATA III HDD (1TB), max. seq. WRITE throughput (w/o NCQ) 43 MB/s RAID 5 array = 7 x HDD + 1 x Hot-Spare HDD (*1) The used WRITE throughput is the result of performance tests. Vendor numbers might not match reality! 9
10 2. Calculation: Max. total READ throughput = (drive # - failed drive #) * Max. WRITE throughput A.) Max. total READ throughput = (7-1) * 122 MB/s = 732 MB/s B.) Max. total READ throughput = (7-1) * 43 MB/s = 258 MB/s 3. Result: A.): 1350 Mbps > 732 MB/s B.): 1350 Mbps > 258 MB/s Max. total WRITE throughput = Bottleneck Configuration A.) B.) Drive NL SAS 6G Toshiba 1TB SATAIII Hitachi 1TB Max. Write Throughput (*1) Rebuild Time Test Environment 122 MB/s 2 hours 09 minutes EonStor DS G7 Raid 5 LD: 1 43 MB/s 6 hours 09 minutes Hard Drive: 7 Hot-Spare: 1 Table 5: WRITE throughput SATA III hard drive vs. NL-SAS hard drive 3.3 The capacity of a failed hard drive The capacity of a failed hard drive is another key factor affecting the rebuild time. As higher the capacity of the failed hard drive, as longer is the rebuild time. Using a hard drive with smaller capacity (ex. 1TB hard drive) can decrease, the rebuild time to 64% using a 2 TB hard drive. Drive Type Model Configuration (RAID 5) Rebuild time Time saving in % NL SAS Toshiba 2TB NL SAS Toshiba 1TB G7 7 HDDs 5 hrs 49 mins 7 HDDs 2 hrs 35 mins 56% Table 6: Capacity of a failed hard drive (*1) The used WRITE throughput is the result of performance tests. Vendor numbers might not match reality! 10
11 4. Factors rebuilding a degraded RAID Estimating the Rebuild Time The rebuild time can be estimated using the following formulas. 4.1 Rebuild time, if computing power is the bottleneck The following formula is suitable using one of the following configurations: Drives per RAID array / sub-array EonStor DS G7 EonStor DS G6 SAS 6G SSD 6 3 NL-SAS HDD 11 7 SATA II / III HDD 11 7 Table 7: Suitable configuration Rebuild time = DC DW DC = Drive capacity in MB (#GB * ) DW = Drive Write Throughput (*1) Example: 1. Configuration: 2. Calculation: Drive Max. Write Throughput Test Environment NL SAS 6G Toshiba 1TB 122 MB/s Table 8: Rebuild Time example configuration EonStor DS G7 Raid 5 LD: 1 Hard Drive: 7 Hot-Spare: 1 Rebuild Time in minutes = (953, ) Result: EonStor DS G7, Rebuild Time = 130 min. (*1) The used WRITE throughput is the result of performance tests. Vendor numbers might not match reality! 11
12 4.2 Rebuild time, if write throughput is the bottleneck In all other cases the rebuild time can be estimated by using the following formula. Rebuild time = DC CP (DN DF) DC = Drive capacity in MB DN = Number of drives DF = Number of failed drives CP = Computing power (EonStor DS G6 = 850 MB/s, EonStor DS G7 = 1,350 MB/s) Example: 1. Configuration: Configuration EonStor Model Max. Computing Power Test Environment A.) B.) G7 G MB/s 850 MB/s Hitachi SSD 400GB Raid 5 LD: 1 Drives: 7 Hot-Spare: 1 Table 9: Rebuild Time example configuration 2. Calculation: A.) Rebuild Time in minutes = (381,470 (1350 (7-1))) 60 B.) Rebuild Time in minutes = (381,470 (850 (7-1))) Result: A.) EonStor DS G7, Rebuild Time = 28 min. B.) EonStor DS G6, Rebuild Time = 45 min. 12
13 5. Factors rebuilding a degraded RAID Appendix: 5.1 Infortrend Web links Infortrend Home: Infortrend Support and Resources: EonStor DS overview: EonStor DS G7 overview: Drive Vendor links Links to drive vendors, whose drives were used for testing: 1. HGST: HUSSL4040ASS600 HUSML4040ASS600 HUA723020ALA640 US7K3000_ds.pdf 2. Toshiba: MK1001TRKB MK2001TRKB Copyright 2012 Infortrend Technology, Inc. All rights reserved. Infortrend, ESVA, EonStor, EonNAS and EonPath are trademarks or registered trademarks of Infortrend. All other marks and names mentioned herein may be trademarks of their respective owners. The information contained herein is subject to change without notice. The content provided as is, without express or implied warranties of any kind. 13 WP_ED_ _GL_1.3
Benefits of Intel Matrix Storage Technology
Benefits of Intel Matrix Storage Technology White Paper December 2005 Document Number: 310855-001 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
Deduplication on EonNAS Pro: UI Configurations and Impact on Capacity Utilization
Deduplication on EonNAS Pro: UI Configurations and Impact on Capacity Utilization Application Note Abstract This application note describes how to configure the deduplication function on Infortrend s EonNAS
EonStor DS remote replication feature guide
EonStor DS remote replication feature guide White paper Version: 1.0 Updated: Abstract: Remote replication on select EonStor DS storage systems offers strong defense against major disruption to IT continuity,
RAID Level Descriptions. RAID 0 (Striping)
RAID Level Descriptions RAID 0 (Striping) Offers low cost and maximum performance, but offers no fault tolerance; a single disk failure results in TOTAL data loss. Businesses use RAID 0 mainly for tasks
EonStor DS 3000 Series
EonStor DS 000 Series High speed flexible storage delivers robust reliability and management Turbo charged storage DS 000T Gen Up to 1.M read IOPS and,00 MBps read throughput High IOPS solutions ideal
Storage node capacity in RAID0 is equal to the sum total capacity of all disks in the storage node.
RAID configurations defined 1/7 Storage Configuration: Disk RAID and Disk Management > RAID configurations defined Next RAID configurations defined The RAID configuration you choose depends upon how you
Using RAID6 for Advanced Data Protection
Using RAI6 for Advanced ata Protection 2006 Infortrend Corporation. All rights reserved. Table of Contents The Challenge of Fault Tolerance... 3 A Compelling Technology: RAI6... 3 Parity... 4 Why Use RAI6...
Self-encrypting drives (SED): helping prevent data loss, theft, and misplacement
Self-encrypting drives (SED): helping prevent data loss, theft, and misplacement White paper Version: 1.0 Updated: Abstract: This white paper introduces Infortrend self-encrypting drive technology, or
Using SSD to boost performance on Infortrend NAS storage systems
Using SSD to boost performance on Infortrend NAS storage systems Application notes Abstract: This document offers a quick and concise introduction of the ways SSD storage can boost the performance of Infortrend
RAID Implementation for StorSimple Storage Management Appliance
RAID Implementation for StorSimple Storage Management Appliance Alpa Kohli June, 2012 KB-00008 Document Revision 1 StorSimple knowledge base articles are intended to provide customers with the information
EonStor DS G7i - Fibre Channel Solutions Affordable and flexible storage solutions featuring enterprise-class data-protection
EonStor DS G7i - Fibre Channel Solutions Affordable and flexible storage solutions featuring enterprise-class data-protection Hybrid Host Connectivity Ÿ 16G/8G Fibre Channel and 1GbE iscsi Host connectivity
Configuring RAID for Optimal Performance
Configuring RAID for Optimal Performance Intel RAID Controller SRCSASJV Intel RAID Controller SRCSASRB Intel RAID Controller SRCSASBB8I Intel RAID Controller SRCSASLS4I Intel RAID Controller SRCSATAWB
Deploying Global Clusters for Site Disaster Recovery via Symantec Storage Foundation on Infortrend Systems
Deploying Global Clusters for Site Disaster Recovery via Symantec Storage Foundation on Infortrend Systems Application Notes Abstract: This document describes how to apply global clusters in site disaster
EonStor DS 3000 Series
EonStor DS 000 Series High Speed Flexible Storage Delivers Robust Reliability and Fast Performance Up to.m IOPS throughput handles the most demanding applications Seamless SSD support The EonStor DS 000
Technology Update White Paper. High Speed RAID 6. Powered by Custom ASIC Parity Chips
Technology Update White Paper High Speed RAID 6 Powered by Custom ASIC Parity Chips High Speed RAID 6 Powered by Custom ASIC Parity Chips Why High Speed RAID 6? Winchester Systems has developed High Speed
WHITEPAPER: Understanding Pillar Axiom Data Protection Options
WHITEPAPER: Understanding Pillar Axiom Data Protection Options Introduction This document gives an overview of the Pillar Data System Axiom RAID protection schemas. It does not delve into corner cases
PowerVault MD1200/MD1220 Storage Solution Guide for Applications
PowerVault MD200/MD220 Storage Solution Guide for Applications A Dell Technical White Paper Dell PowerVault Storage Systems Joe Noyola Systems Performance Analysis Group Chuck Colburn Storage Advanced
EonStor DS High-Density Storage: Key Design Features and Hybrid Connectivity Benefits
EonStor DS High-Density Storage: Key Design Features and Hybrid Connectivity Benefits White Paper Abstract This white paper introduces the key design features and hybrid FC/iSCSI connectivity benefits
Technical White paper RAID Protection and Drive Failure Fast Recovery
Technical White paper RAID Protection and Drive Failure Fast Recovery RAID protection is a key part of all ETERNUS Storage Array products. Choices of the level chosen to meet customer application requirements
Automated Data-Aware Tiering
Automated Data-Aware Tiering White Paper Drobo s revolutionary new breakthrough technology automates the provisioning, deployment, and performance acceleration for a fast tier of SSD storage in the Drobo
ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide
ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide The ServeRAID M5015 and ServeRAID M5014 SAS/SATA Controllers for IBM System x are the next-generation 6 Gbps SAS
Intel RAID SSD Cache Controller RCS25ZB040
SOLUTION Brief Intel RAID SSD Cache Controller RCS25ZB040 When Faster Matters Cost-Effective Intelligent RAID with Embedded High Performance Flash Intel RAID SSD Cache Controller RCS25ZB040 When Faster
Understanding Storage Virtualization of Infortrend ESVA
Understanding Storage Virtualization of Infortrend ESVA White paper Abstract This white paper introduces different ways of implementing storage virtualization and illustrates how the virtualization technology
EonStor DS 3000 Series
EonStor DS 000 Series High Speed Flexible Storage Delivers Robust Reliability and Fast Performance Up to.m IOPS throughput handles the most demanding applications Seamless SSD support Flexibility Choose
The Effect of Priorities on LUN Management Operations
Abstract This white paper describes the effect of each of the four Priorities (ASAP, High, Medium, and Low) on overall EMC CLARiiON performance in executing. The LUN Management Operations are migrate,
PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector
PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector StarTech ID: PEXSAT34SFF The PEXSAT34SFF PCI Express SATA Controller Card enables 4 AHCI SATA III connections to
ServeRAID H1110 SAS/SATA Controller for IBM System x IBM System x at-a-glance guide
ServeRAID H1110 SAS/SATA Controller for IBM System x IBM System x at-a-glance guide The ServeRAID H1110 SAS/SATA Controller for IBM System x offers a low-cost enterprise-grade RAID solution for internal
Cloud Storage. Parallels. Performance Benchmark Results. White Paper. www.parallels.com
Parallels Cloud Storage White Paper Performance Benchmark Results www.parallels.com Table of Contents Executive Summary... 3 Architecture Overview... 3 Key Features... 4 No Special Hardware Requirements...
4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card
4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card User Manual Model: UGT-ST644R All brand names and trademarks are properties of their respective owners www.vantecusa.com Contents: Chapter 1: Introduction...
Guide to SATA Hard Disks Installation and RAID Configuration
Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation...2 1.1 Serial ATA (SATA) Hard Disks Installation...2 2. Guide to RAID Configurations...3 2.1 Introduction
QuickSpecs. Models HP Smart Array E200 Controller. Upgrade Options Cache Upgrade. Overview
Overview The HP Smart Array E200 is HP's first entry level PCI Express (PCIe) Serial Attached SCSI (SAS) RAID controller. The full size card has 8 ports and utilizes DDR1-266 memory. The E200 is ideal
Improving Lustre OST Performance with ClusterStor GridRAID. John Fragalla Principal Architect High Performance Computing
Improving Lustre OST Performance with ClusterStor GridRAID John Fragalla Principal Architect High Performance Computing Legacy RAID 6 No Longer Sufficient 2013 RAID 6 data protection challenges Long rebuild
How To Backup A Virtualized Environment
Disk-based Backup for Virtualized Environment via Infortrend EonStor DS, ESVA, EonNAS 3000 / 5000 and Veeam Backup and Replication Application Note Abstract The document describes, as an example the usage
IBM ^ xseries ServeRAID Technology
IBM ^ xseries ServeRAID Technology Reliability through RAID technology Executive Summary: t long ago, business-critical computing on industry-standard platforms was unheard of. Proprietary systems were
This chapter explains how to update device drivers and apply hotfix.
MegaRAID SAS User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter explains an overview
Lecture 36: Chapter 6
Lecture 36: Chapter 6 Today s topic RAID 1 RAID Redundant Array of Inexpensive (Independent) Disks Use multiple smaller disks (c.f. one large disk) Parallelism improves performance Plus extra disk(s) for
DELL RAID PRIMER DELL PERC RAID CONTROLLERS. Joe H. Trickey III. Dell Storage RAID Product Marketing. John Seward. Dell Storage RAID Engineering
DELL RAID PRIMER DELL PERC RAID CONTROLLERS Joe H. Trickey III Dell Storage RAID Product Marketing John Seward Dell Storage RAID Engineering http://www.dell.com/content/topics/topic.aspx/global/products/pvaul/top
Improving IT Operational Efficiency with a VMware vsphere Private Cloud on Lenovo Servers and Lenovo Storage SAN S3200
Improving IT Operational Efficiency with a VMware vsphere Private Cloud on Lenovo Servers and Lenovo Storage SAN S3200 Most organizations routinely utilize a server virtualization infrastructure to benefit
NEC ESMPRO Manager RAID System Management Guide for VMware ESXi 5 or later
NEC ESMPRO Manager RAID System Management Guide for VMware ESXi 5 or later 856-127900-613-G 7th Edition Jun. 2015 Copyright NEC Corporation 2015. Trademarks NEC EXPRESSBUILDER is trademarks of NEC Corporation.
RAID Performance Analysis
RAID Performance Analysis We have six 500 GB disks with 8 ms average seek time. They rotate at 7200 RPM and have a transfer rate of 20 MB/sec. The minimum unit of transfer to each disk is a 512 byte sector.
Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio.
Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...
Microsoft Exchange 2010 on Dell Systems. Simple Distributed Configurations
Microsoft Exchange 2010 on Dell Systems Simple Distributed Configurations Global Solutions Engineering Dell Product Group Microsoft Exchange 2010 on Dell Systems Simple Distributed Configurations This
Total Cost of Solid State Storage Ownership
Total Cost of Solid State Storage Ownership An In-Depth Analysis of Many Important TCO Factors SSSI Members and Authors: Esther Spanjer, SMART Modular Technologies Dan Le, SMART Modular Technologies David
5-BAY RAID STATION. Manual
5-BAY RAID STATION Manual Content 1. Features 3 1.1 Overview 3 1.2 SATA features 3 1.3 USB features 4 2. Specifications 4 3. System requirements 4 4. The device at a glance 4 4.1 Rear panel 5 4.2 The LED
Guide to SATA Hard Disks Installation and RAID Configuration
Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation... 2 1.1 Serial ATA (SATA) Hard Disks Installation... 2 2. Guide to RAID Configurations... 3 2.1 Introduction
PIONEER RESEARCH & DEVELOPMENT GROUP
SURVEY ON RAID Aishwarya Airen 1, Aarsh Pandit 2, Anshul Sogani 3 1,2,3 A.I.T.R, Indore. Abstract RAID stands for Redundant Array of Independent Disk that is a concept which provides an efficient way for
Version : 1.1. SR2760-2S-S2 User Manual. SOHORAID Series
Version : 1.1 SR2760-2S-S2 User Manual SOHORAID Series Forewords About this manual Thank you for using products from Raidon Technology Inc. This manual will introduce the STARDOM SR2760-2S-S2 product.
Using EonOne to Centralize the Management of all EonNAS devices
Using EonOne to Centralize the Management of all EonNAS devices Application Note Abstract This application note describes how to manage multiple EonNAS devices across your network with the help of EonOne.
Best Practices RAID Implementations for Snap Servers and JBOD Expansion
STORAGE SOLUTIONS WHITE PAPER Best Practices RAID Implementations for Snap Servers and JBOD Expansion Contents Introduction...1 Planning for the End Result...1 Availability Considerations...1 Drive Reliability...2
Assessing RAID ADG vs. RAID 5 vs. RAID 1+0
White Paper October 2001 Prepared by Industry Standard Storage Group Compaq Computer Corporation Contents Overview...3 Defining RAID levels...3 Evaluating RAID levels...3 Choosing a RAID level...4 Assessing
Minimum Hardware Configurations for EMC Documentum Archive Services for SAP Practical Sizing Guide
Minimum Hardware Configurations for EMC Documentum Archive Services for SAP Practical Sizing Guide Abstract The sizing of hardware in a deployment of EMC Document Archive Services for SAP is determined
RAID technology and IBM TotalStorage NAS products
IBM TotalStorage Network Attached Storage October 2001 RAID technology and IBM TotalStorage NAS products By Janet Anglin and Chris Durham Storage Networking Architecture, SSG Page No.1 Contents 2 RAID
an analysis of RAID 5DP
an analysis of RAID 5DP a qualitative and quantitative comparison of RAID levels and data protection hp white paper for information about the va 7000 series and periodic updates to this white paper see
Intel Matrix Storage Manager 8.x
Intel Matrix Storage Manager 8.x User's Manual January 2009 Revision 1.0 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
RAID 5 rebuild performance in ProLiant
RAID 5 rebuild performance in ProLiant technology brief Abstract... 2 Overview of the RAID 5 rebuild process... 2 Estimating the mean-time-to-failure (MTTF)... 3 Factors affecting RAID 5 array rebuild
HP Embedded SATA RAID Controller
HP Embedded SATA RAID Controller User Guide Part number: 433600-001 First Edition: June 2006 Legal notices Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject
New Advanced RAID Level for Today's Larger Storage Capacities: Advanced Data Guarding
White Paper October 2000 Prepared by Storage Products Group Compaq Computer Corporation Contents Introduction...2 What customers can expect from Compaq RAID ADG solution...3 RAID ADG Features and Benefits...3
Contents. Overview. Drive Policy RAID 500 features. Disable BGI RAID 700 features. Management Tasks Choosing the RAID Level.
Configuring ThinkServer RAID 500 and RAID 700 Adapters Contents Overview 2 Drive Policy 28 RAID 500 features 2 Disable BGI 28 RAID 700 features 2 Adapter Properties 28 RAID Overview 2 Management Tasks
Configuring ThinkServer RAID 100 on the TS140 and TS440
Configuring ThinkServer RAID 100 on the TS140 and TS440 Lenovo ThinkServer TS Series Servers Lenovo Enterprise Product Group Version 1.0 September 17, 2013 2013 Lenovo. All rights reserved. LENOVO PROVIDES
HDD Troubleshooting. This manual is intended for professional installers not for end users. Please handle this information with care.
This manual is intended for professional installers not for end users. Please handle this information with care. Overview This manual describes what to do in case a built-in HDD develops a malfunction
Definition of RAID Levels
RAID The basic idea of RAID (Redundant Array of Independent Disks) is to combine multiple inexpensive disk drives into an array of disk drives to obtain performance, capacity and reliability that exceeds
SATA RAID SIL 3112 CONTROLLER USER S MANUAL
SATA RAID SIL 3112 CONTROLLER USER S MANUAL 120410056E1N Copyright Copyright 2003. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system
Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.
Embedded MegaRAID SATA User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter introduces
RAID Basics Training Guide
RAID Basics Training Guide Discover a Higher Level of Performance RAID matters. Rely on Intel RAID. Table of Contents 1. What is RAID? 2. RAID Levels RAID 0 RAID 1 RAID 5 RAID 6 RAID 10 RAID 0+1 RAID 1E
Intel Rapid Storage Technology
Intel Rapid Storage Technology User Guide August 2011 Revision 1.0 1 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
Intel RAID Software User s Guide:
Intel RAID Software User s Guide: Intel Embedded Server RAID Technology II Intel Integrated Server RAID Intel RAID Controllers using the Intel RAID Software Stack 3 July, 2007 Intel Order Number: D29305-005
Performance Report Modular RAID for PRIMERGY
Performance Report Modular RAID for PRIMERGY Version 1.1 March 2008 Pages 15 Abstract This technical documentation is designed for persons, who deal with the selection of RAID technologies and RAID controllers
RAIDCore User Manual P/N 83-00004638-12 Revision A December 2009
RAIDCore User Manual P/N 83-00004638-12 Revision A December 2009 Copyright Protected Material 2009. All rights reserved. All other trademarks and registered trademarks are proprietary to their respective
Dynamic Disk Pools Technical Report
Dynamic Disk Pools Technical Report A Dell Technical White Paper Dell PowerVault MD3 Dense Series of Storage Arrays 9/5/2012 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL
Education. Servicing the IBM ServeRAID-8k Serial- Attached SCSI Controller. Study guide. XW5078 Release 1.00
Education Servicing the IBM ServeRAID-8k Serial- Attached SCSI Controller Study guide XW5078 Release 1.00 May 2006 Servicing the IBM ServeRAID-8k Serial- Attached SCSI (SAS) Controller Overview The ServeRAID
Using VMWare VAAI for storage integration with Infortrend EonStor DS G7i
Using VMWare VAAI for storage integration with Infortrend EonStor DS G7i Application Note Abstract: This document describes how VMware s vsphere Storage APIs (VAAI) can be integrated and used for accelerating
NVIDIA RAID Installation Guide
NVIDIA RAID Installation Guide 1. NVIDIA BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID. 2 1.2 RAID Configurations Precautions.. 3 1.3 Create Disk Array. 4 2. NVIDIA Windows RAID Installation
RAID. Contents. Definition and Use of the Different RAID Levels. The different RAID levels: Definition Cost / Efficiency Reliability Performance
RAID Definition and Use of the Different RAID Levels Contents The different RAID levels: Definition Cost / Efficiency Reliability Performance Further High Availability Aspects Performance Optimization
How To Create A Multi Disk Raid
Click on the diagram to see RAID 0 in action RAID Level 0 requires a minimum of 2 drives to implement RAID 0 implements a striped disk array, the data is broken down into blocks and each block is written
User s Manual. Home CR-H212. 2.5 2-BAY RAID Storage Enclosure
User s Manual Home CR-H212 2.5 2-BAY RAID Storage Enclosure 1 Introduction 1.1 Features - 2-Bay Bus Powered Portable RAID Enclosure -Works with SATA HDD or SSD -Supports Big (JBOD), RAID0, RAID1, and Normal
Intel RAID Software User s Guide:
Intel RAID Software User s Guide: Intel Embedded Server RAID Technology II Intel Integrated Server RAID Intel RAID Controllers using the Intel RAID Software Stack 3 Revision 8.0 August, 2008 Intel Order
RAID OPTION ROM USER MANUAL. Version 1.6
RAID OPTION ROM USER MANUAL Version 1.6 RAID Option ROM User Manual Copyright 2008 Advanced Micro Devices, Inc. All Rights Reserved. Copyright by Advanced Micro Devices, Inc. (AMD). No part of this manual
RAID Technology Overview
RAID Technology Overview HP Smart Array RAID Controllers HP Part Number: J6369-90050 Published: September 2007 Edition: 1 Copyright 2007 Hewlett-Packard Development Company L.P. Legal Notices Copyright
Configuring ThinkServer RAID 500 and RAID 700 Adapters. Lenovo ThinkServer
Configuring ThinkServer RAID 500 and RAID 700 Adapters Lenovo ThinkServer October 4, 2011 Contents Overview... 4 RAID 500 features... 4 RAID 700 features... 4 RAID Overview... 4 Choosing the RAID Level...
Models Smart Array 6402A/128 Controller 3X-KZPEC-BF Smart Array 6404A/256 two 2 channel Controllers
Overview The SA6400A is a high-performance Ultra320, PCI-X array controller. It provides maximum performance, flexibility, and reliable data protection for HP OpenVMS AlphaServers through its unique modular
PA-5000 Series SSD Storage Options Configuring RAID and Disk Backup
PA-5000 Series SSD Storage Options Configuring RAID and Disk Backup 2014, Palo Alto Networks, Inc. https://paloaltonetworks.com/documentation P/N 810-000076-00C Contents OVERVIEW...3 SSD UPGRADE PROCEDURE...3
VMware Virtual SAN Backup Using VMware vsphere Data Protection Advanced SEPTEMBER 2014
VMware SAN Backup Using VMware vsphere Data Protection Advanced SEPTEMBER 2014 VMware SAN Backup Using VMware vsphere Table of Contents Introduction.... 3 vsphere Architectural Overview... 4 SAN Backup
Comprehending the Tradeoffs between Deploying Oracle Database on RAID 5 and RAID 10 Storage Configurations. Database Solutions Engineering
Comprehending the Tradeoffs between Deploying Oracle Database on RAID 5 and RAID 10 Storage Configurations A Dell Technical White Paper Database Solutions Engineering By Sudhansu Sekhar and Raghunatha
Q & A From Hitachi Data Systems WebTech Presentation:
Q & A From Hitachi Data Systems WebTech Presentation: RAID Concepts 1. Is the chunk size the same for all Hitachi Data Systems storage systems, i.e., Adaptable Modular Systems, Network Storage Controller,
RAID Utility User Guide. Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card
RAID Utility User Guide Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card Contents 3 RAID Utility User Guide 3 The RAID Utility Window 4 Running RAID Utility
How To Scale Myroster With Flash Memory From Hgst On A Flash Flash Flash Memory On A Slave Server
White Paper October 2014 Scaling MySQL Deployments Using HGST FlashMAX PCIe SSDs An HGST and Percona Collaborative Whitepaper Table of Contents Introduction The Challenge Read Workload Scaling...1 Write
3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering
3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering StarTech ID: PEXMSATA343 The PEXMSATA343 3-Port PCI Express 2.0 SATA Card with HyperDuo adds an internal
Technical Brief. MediaShield Storage Technology: Confidently Storing Your Digital Assets. March 2007 TB-01760-001_v03
Technical Brief MediaShield Storage Technology: Confidently Storing Your Digital Assets March 2007 TB-01760-001_v03 Table of Contents Overview...1 Industry-Defined Multidish Techniques...3 RAID 0: Disk
IBM Spectrum Scale vs EMC Isilon for IBM Spectrum Protect Workloads
89 Fifth Avenue, 7th Floor New York, NY 10003 www.theedison.com @EdisonGroupInc 212.367.7400 IBM Spectrum Scale vs EMC Isilon for IBM Spectrum Protect Workloads A Competitive Test and Evaluation Report
Reliability and Fault Tolerance in Storage
Reliability and Fault Tolerance in Storage Dalit Naor/ Dima Sotnikov IBM Haifa Research Storage Systems 1 Advanced Topics on Storage Systems - Spring 2014, Tel-Aviv University http://www.eng.tau.ac.il/semcom
PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering
PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering StarTech ID: PEXSAT34SFF The PEXSAT34SFF PCI Express 2.0 SATA Controller Card enables 4 AHCI SATA III
USER S GUIDE. MegaRAID SAS Software. June 2007 Version 2.0. 80-00156-01, Rev. B
USER S GUIDE MegaRAID SAS Software June 2007 Version 2.0 80-00156-01, Rev. B This document contains proprietary information of LSI Corporation. The information contained herein is not to be used by or
Remote/Branch Office IT Consolidation with Lenovo S2200 SAN and Microsoft Hyper-V
Remote/Branch Office IT Consolidation with Lenovo S2200 SAN and Microsoft Hyper-V Most data centers routinely utilize virtualization and cloud technology to benefit from the massive cost savings and resource
Getting Started With RAID
Dell Systems Getting Started With RAID www.dell.com support.dell.com Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A
EMC Backup and Recovery for Microsoft SQL Server 2008 Enabled by EMC Celerra Unified Storage
EMC Backup and Recovery for Microsoft SQL Server 2008 Enabled by EMC Celerra Unified Storage Applied Technology Abstract This white paper describes various backup and recovery solutions available for SQL
