1 2011 National Electrical Code Changes of Interest to Data/Comm Cabling Contractors, Users and Code Enforcement Officials The National Electrical Code is published by the National Fire Protection Association with revisions on a three-year schedule. The 2011 NEC, which replaces the 2008 NEC, was released by NFPA in August There were many changes of interest to manufacturers, installers and users of communications cable and connectivity products. The purpose of this document is to educate and communicate those relevant changes in the NEC. The place to start reading the National Electrical Code is in the beginning, in Article 90-Introduction. Although there are no significant changes to Article 90 in the 2011 NEC, we start with this article because it contains special arrangements for communications installations. NFPA 70, NFPA, National Fire Protection Association, National Electrical Code, and NEC are registered trademarks of the National Fire Protection Association. Page 1 of 21

2 Article 90 Introduction Section 90.2 Scope states that the NEC covers the installation of electrical conductors, equipment, and raceways; signaling and communications conductors, equipment, and raceways; and optical fiber cables and raceways in Public and private premises, including buildings, structures, mobile homes, recreational vehicles, and floating buildings. It also states the Code does not cover Installations of communications equipment under the exclusive control of communications utilities located outdoors or in building spaces used exclusively for such installations. Section 90.3 Code Arrangement states that Chapters 1, 2, 3, and 4 apply generally and that Chapter 8 covers communications systems and is not subject to the requirements of Chapters 1 through 7 except where the requirements are specifically referenced in Chapter 8. Section 90.2 also states that Chapters 5, 6, and 7 apply to special occupancies, special equipment, or other special conditions. These latter chapters supplement or modify the general rules. What is the significance of these requirements? The NEC covers communications equipment, wires and cables installed in most buildings; it includes optical fiber cables and raceways too. However, it exempts telephone company central offices because it has an exemption for communications utility installations under the exclusive control of the utility. It does not exempt telephone switching offices run by a nonutility such as a large university or a nonutility provider of telephone service. Also, the communications chapter (Chapter 8) of the NEC is independent of the rest of the code; only those electrical wiring requirements in Chapters 1 through 7 that are referenced in Chapter 8 apply to Chapter 8. One example is that the cable tray fill requirements in Article 392 (Cable Trays) do not apply to installations of communications cables covered by Chapter 8. They do apply to installations of data cables (class 2 cables) because these are in Article 725. They don t apply to optical fiber cables because the cable tray fill requirements are written apply to electrical cables only. Data wiring (class 2 wiring) is covered by Article 725 and some computer room installations are covered by Article 645. These Articles are permitted to (and do) modify the general wiring rules in Chapters 1 through 4; however they are not permitted to modify the wiring rules for communications installations without a reference from Chapter 8; this is significant for installations of communications equipment in a computer room where Article 645 is applied to the IT equipment but not the communications equipment. Page 2 of 21

3 Wiring in Air Ducts and Plenums ARTICLE 300 Wiring Methods New Section (C)(2) was added to cover wiring supported by cable trays in other spaces used for environmental air. Section (C)(2)(a) permits metal cable tray systems to support the various wiring methods that are permitted to be installed in other spaces used for environmental air. Section (C)(2)(b) permits wiring methods that are not already permitted to be installed in other spaces used for environmental air to be installed in solid side and bottom cable tray systems with solid metal covers. Section (C) has been revised to clarify that Other Spaces Used for Environmental Air (Plenum) applies to spaces not specifically fabricated for environmental air-handling purposes but used for air-handling purposes as a plenum. The section also has a new Informational Note that states that the phrase Other Spaces Used for Environmental Air (Plenum) correlates with the term plenum in NFPA 90A- 2009, Standard for the Installation of Air-Conditioning and Ventilating Systems where the plenum is used for return air purposes, as well as some other airhandling spaces. Section (C)(2) in the 2008 NEC has requirements for equipment installed in other spaces used for environmental air. An Informational Note was added in the 2011 NEC in section (C)(3) to provide guidance on how to test that equipment. Reference is made to ANSI/UL , Fire Test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces. What is the significance of these changes? Section (C)(1) in the 2008 NEC, which lists all the permissible wiring methods for other spaces used for environmental air, includes only one type of cable tray system, solid bottom metal cable tray with solid metal covers. It doesn t permit open cable trays even if the cable tray supports wiring methods such as Type CMP cable that is permitted in a return air plenum unsupported by a cable tray. That oversight has been fixed in the 2011 NEC which permits plenum cables to be supported by open metal cable trays in a typical ceiling or underfloor plenum installation. Page 3 of 21

4 The informational note referring to NFPA 90A is significant because the NFPA Standards Council has assigned primary responsibility for fire protection of combustibles in air handling spaces to the Technical Committee on Air-Conditioning and it s document NFPA 90A, Standard for the Installation of Air-Conditioning and Ventilating Systems. Correlating NFPA 70 (the NEC) and NFPA 90A is complicated by the difference in terminology used in the two documents. See the table below for a guide to reconciling the terminology used in the two documents. NFPA 90A Terminology Air Duct Plenum Ceiling Cavity Plenum Raised Floor Plenum Air-Handling Unit Room Plenum Apparatus Casing Plenum NEC Terminology Duct Specifically Fabricated for Environmental Air (300.22(B)) Plenum Other Spaces Used for Environmental Air (Plenum) Other Spaces Used for Environmental Air (Plenum) Other Spaces Used for Environmental Air (Plenum) Plenum Specifically Fabricated to Transport Environmental Air (300.22(B) in the 2008 NEC) Section of NFPA 90A-2009 states that Wiring shall not be installed in air ducts unless it is directly associated with the air distribution system and does not exceed 1.22m (4 ft). The listing requirements for the four-foot lengths of plenum cable that are permitted are the listing requirements currently used by UL and other testing laboratories to list plenum cable. Annex note A explains that Electrical wires and cables and optical fiber cables installed in metal raceways or metal sheathed cable are not considered to be exposed to the airflow, and need not meet the requirements of NEC section (C) correlates with section of NFPA 90A-2009 in its requirements for wiring in air ducts. Section of NFPA 90A-2009 states that Electrical wires and cables or optical fiber cables, or optical fiber and communications raceways in apparatus casing plenums shall comply with When the title of section (B) was changed from Ducts or Plenums Used for Environmental Air in the 2008 NEC to Ducts Specifically Fabricated for Environmental Air in the 2011 NEC, the NEC lost any requirements for wiring in apparatus casing plenums. NFPA 90A-2009 defines an apparatus casing plenum as A sheet metal construction attached directly to a fan enclosure, fan coil unit, air handling unit, or furnace bonnet for the purpose of connecting distribution ducts. The loss of coverage for wiring in apparatus casing plenums is not significant because it is unlikely that there would ever be any reason to install wiring in one. Page 4 of 21

5 Section (D) in the 2008 and the 2011 NEC defers to Article 645 for Electrical wiring in air-handling areas beneath raised floors for information technology equipment and thereby correlates with section of NFPA 90A-2009 that exempts electrical wires, listed plenum communication and optical-fiber raceways, and opticalfiber cables in computer/data processing rooms from the wiring rules for cables in raised floor plenums provided the computer rooms are designed and installed in accordance with NFPA 75, Standard for the Protection of Information Technology Equipment. Article 645 Information Technology Equipment Conditions for the Use of Article 645 Section of Article 645 in the 2008 NEC states This article shall apply, provided all of the following conditions are met: It then lists five conditions. Section of Article 645 in the 2011 NEC states This article shall be permitted to provide alternate wiring methods to the provisions of Chapters 1 through 4 for power wiring, for signaling wiring, and (C) and Table (a) for optical fiber cabling when all of the following conditions are met: It then lists six conditions. What is the significance of this change? Article 645 is based on an engineering trade-off. In return for providing additional fire protection (that s the 5 or 6 conditions) relief from the plenum wiring rules for power wiring and signaling cabling is permitted. At least that is generally recognized as the intent, however the 2008 NEC required (shall apply) that the article be used if the 5 conditions were met. The 2011 NEC has been reworded to clarify that the use of the article is voluntary (shall be permitted) and furthermore clearly states that the alternative wiring methods are for power wiring (Chapters 1 through 4) and data wiring and optical fiber cabling only. No mention is made of communications wiring because Article 645 is not permitted to modify the requirements for communications wiring without a reference from Article 800 (Communications), and there is no reference to Article 645 in Article 800. Article 645 permits the use of non-plenum-rated power cords and non-plenum-rated data cables in the underfloor plenum but it does not permit the use on non-plenum-rated communications cables if the cables are connected to communications equipment. Definitions Section has five new definitions: 1. Critical Operations Data System 2. Information Technology Equipment (ITE) 3. Information Technology Equipment Room 4. Remote Disconnect Control 5. Zone Page 5 of 21

6 What is the significance of these new definitions? Clearly an article covering Information Technology Equipment is incomplete without a definition of what the article is all about. The difficulty in defining IT equipment is that it s very similar to the definition of communications equipment. A definition of Communications Equipment is in Article 100 and it is not new to this edition of the Code. The definition of IT Equipment states what it is (creates and manipulates data, voice and video) and that it is not communications equipment processing communications circuits. Communications circuits are defined in Basically the definition of IT Equipment defers to the definition of Communications Equipment; any equipment that appears to be both IT Equipment and Communications Equipment is Communications Equipment. Since it is Communications Equipment, the installation requirements are in Article 800, not Article 645. The definition of IT Equipment correlates with sections (D)(1) and (A)(1)(c) which state that when a class 2 or 3 circuit and a communications circuit are in the same cable, the class 2 or 3 circuit is reclassified as a communications circuit. Data circuits are class 2 or 3 circuits; see (A)(4). It is equally clear that an article that covers information technology equipment in an information technology equipment room needs to have a definition of an IT Equipment Room. The new definition is extracted from NFPA , Standard for the Protection of Information Technology Equipment. Likewise, a definition of zone is required because large computer rooms are divided into zones for fire protection. The definition of zone is new in the 2011 edition of the Code. Critical Operations Data Systems and Remote Disconnect Control are defined because these new concepts are the basis for a major technical change in Article 645. (Continue on to read about that change.) Other Articles Section Other Articles was added to the 2011 NEC. It covers: (A) Spread of Fire or Products of Combustion. (B) Plenums. (C) Grounding. (D) Electrical Classification of Data Circuits. (E) Fire Alarm Equipment. (F) Communications Equipment. (G) Community Antenna Television and Radio Distribution Systems Equipment. Page 6 of 21

7 What is the significance of this new section? It has become common practice for electrical inspectors to classify any room with a raised floor and computers in it to be a computer room that must comply with Article 645. The new Other Articles section clarifies which other parts of the Code apply. Section (A) refers to the firestopping sections of the code. Section (B) refers to all the sections that cover wiring in an other space used for environmental air above an IT room, i.e., a ceiling cavity plenum. There is no relief from the plenum wiring requirements for other spaces used for environmental air above an IT room, only in the space beneath it in the raised floor plenum. Section (C) refers to the grounding requirements for conductive optical fiber cables such as armored optical fiber cables. Section (D) leads the user to the reclassification of class 2 and 3 circuits as communications circuits when they are in the same cable with communications circuits. Section (E) defers to Article 760 for the installation of fire alarm systems in an IT room. Section (F) defers to Article 800 for the installation of communications equipment in an IT room, but asserts that the powering of communications equipment in an IT room is covered by Article 645. There is no conflict with Article 800 if Article 645 covers the power wiring for communications equipment because Article 800 has no provision for powering of communications equipment. Section (G) is similar to section (F) but it applies CATV systems. Abandoned Cables Section 645(F) of the 2008 NEC requires that abandoned cables be removed unless they are contained in metal raceway. The 2011 NEC deleted the word metal. What is the significance of this change? Cables in raceways both metallic and nonmetallic will not be required to be removed thereby treating metallic and nonmetallic raceways the same. Page 7 of 21

8 Disconnection Means (Emergency Power Off) Section of the 2008 NEC requires that there be disconnecting means for each zone in the IT room. Section of the 2011 NEC has two alternatives for the disconnecting means, (A) covers remote disconnect controls with requirements the same as the 2008 NEC and (B) covers critical operations data systems. Critical operations data systems (defined in 645.2) are permitted to have alternate disconnecting means provided that five additional conditions are met: (1) An approved shut down procedure has been established (2) Qualified personnel are continuously available 24/7 (3) Smoke sensors are in place. (4) A fire suppression system is in place. (5) Plenum cables are used for signaling What is the significance of this change? Compliance with Section of the 2008 NEC is typically achieved by placing an emergency power off (EPO) switch at each door. There are documented cases of unscheduled shut downs of computer rooms by the accidental or improper engagement of the EPO. In order to deal with this issue, section of the 2011 NEC has two alternatives for the disconnecting means, the traditional EPO at the door or an alternative process for critical IT rooms. Just as the provisions of Article 645 involve an engineering trade-off of additional fire protection in exchange for relief from the plenum wiring rules, the critical operations data system involves an additional engineering trade-off of providing more fire protection in exchange for relief from having an EPO by the door. Part of that additional trade-off is to undo part of the existing engineering trade-off is that the raison d être for the article, viz., relief from the plenum wiring rules. Critical operations data systems still have a dispensation from the plenum wiring rules for power cables but plenum grade signaling cables are required. Page 8 of 21

9 ARTICLE 770 Optical Fiber Cables and Raceways ARTICLE 800 Communications Circuits ARTICLE 820 Community Antenna Television and Radio Distribution Systems & ARTICLE 830 Network-Powered Broadband Communications Systems The changes to these articles are presented together because of the high degree of parallelism between these articles. Optical Fiber, Communications and CATV Raceways Section of the 2008 NEC which contained the listing requirements for Plenum, Riser and General-Purpose CATV Raceways was deleted and does not appear in the 2011 NEC. Likewise all applications and installation rules for CATV raceway were deleted. Communications raceways are now permitted to be used in all applications that previously used CATV raceways. Another new use for communications raceways is as a permitted substitute for optical fiber raceways. Optical fiber and communications raceways have now been defined in Articles 770 and 800 and their permitted applications were changed to prohibit them from installation in air ducts. The applications of optical fiber raceways and communications raceways are shown in the tables below. See Table (a) in the 2011 NEC for a complete table showing the Applications of Listed Optical Fiber Cables and Raceways, and Cable Routing Assemblies in Buildings. See Table (a) for the comparable table for communications. Page 9 of 21

10 Applications of Optical Fiber Raceways Raceway Type Applications Plenum Optical Fiber Raceway Riser Optical Fiber Raceway General- Purpose Optical Fiber Raceway In Air Ducts In Other Spaces Used for Environmental Air (Ceiling Cavity, Raised Floor and Air-Handling Room Plenums) In air ducts N N N In metal raceway that complies with (B) Y Y Y In other spaces used for environmental air Y N N In metal raceway that complies with (C) Y Y Y Supported by open metal cable trays Y N N Supported by solid bottom metal cable trays with solid metal covers Y Y Y In vertical runs Y Y N In metal raceways Y Y Y In Risers In fireproof shafts Y Y Y In riser cable routing assemblies N N N In one- and two-family dwellings Y Y Y General Y Y Y Within Buildings in other than Air-Handling Spaces and Risers Supported by cable trays Y Y Y In distributing frames and cross connect arrays Y Y Y In any raceway recognized in Chapter 3 Y Y Y Page 10 of 21

11 Applications of Communications Raceways Applications Plenum Communications Raceways Raceway Type Riser Communications Raceways General-Purpose Communications Raceways In air ducts N N N In Air Ducts In metal raceway that complies with (B) Y Y Y In Other Spaces Used for Environmental Air (Ceiling Cavity, Raised Floor and Air-Handling Room Plenums) In other spaces used for environmental air In metal raceway that complies with (C) Y N N Y Y Y Supported by open metal cable trays N N N Supported by solid bottom metal cable trays with solid metal covers Y Y Y In vertical runs Y Y N In metal raceways Y Y Y In Risers In fireproof shafts Y Y Y In riser cable routing assemblies N N N In one- and two-family dwellings Y Y Y General Y Y Y In one- and two-family dwellings Y Y Y In multifamily dwellings Y Y Y Within Buildings in Other Than Air-Handling Spaces and Risers In nonconcealed spaces Y Y Y Supported by cable trays Y Y Y Under carpet N N N In distributing frames and cross-connect arrays Y Y Y In any raceway recognized in Chapter 3 Y Y Y Page 11 of 21

12 What is the significance of these changes? Signaling (Article 725), Optical Fiber (Article 770), Communications (Article 800) and CATV Raceways (Article 820) are all available in plenum, riser and general-purpose grades. A great deal of redundancy exists because, for example, the only difference between Signaling, Optical Fiber, Communications and CATV plenum raceways is the label. The same is true for the riser and general-purpose versions. Panel 16 started the process of reducing redundancy by eliminating the CATV raceways and permitting communications raceways to be used instead. Further reduction in redundancy in future editions of the NEC is facilitated by permitting communications raceways to substitute for optical fiber raceways. Optical fiber and communications raceways were prohibited from installation in air ducts in order to correlate with section of NFPA 90A Introduction of Cable Routing Assemblies Cable routing assemblies are defined in section and listing requirements for general-purpose and riser grades are in sections and Applications and installation rules are in sections and These sections were completely rewritten (more about that below) and the cable routing assemblies were included in the revisions. The applications of cable routing assemblies are shown in the table below. See Table (a) in the 2011 NEC for a complete table showing the Applications of Listed Optical Fiber Cables and Raceways, and Cable Routing Assemblies in Buildings. The introduction of cable routing assemblies was also accommodated in sections , , and which cover which cables are permitted together in the same raceway, cable tray enclosure and now cable routing assemblies. The cables from Articles 770, 800, 820 and the low power cables from Article 830 are permitted together in cable routing assemblies. Page 12 of 21

13 Applications of Cable Routing Assemblies Cable Routing Assembly Type Applications Riser Cable Routing Assemblies General-Purpose Cable Routing Assemblies In Air Ducts In air ducts N N In metal raceway that complies with (B) N N In other spaces used for environmental air N N In Other Spaces Used for Environmental Air (Ceiling Cavity, Raised Floor and Air-Handling Room Plenums) In metal raceway that complies with (C) N N In plenum optical fiber and communications raceways N N Supported by open metal cable trays N N Supported by solid bottom metal cable trays with solid metal covers N N In vertical runs Y N In metal raceways N N In fireproof shafts Y Y In Risers In plenum optical fiber and communications raceways N N In riser optical fiber and communications raceways N N In riser cable routing assemblies N N In one- and two-family dwellings Y Y General Y Y Supported by cable trays N N In distributing frames and cross connect arrays Y Y Within Buildings in other than Air-Handling Spaces and Risers In any raceway recognized in Chapter 3 N N In plenum optical fiber and communications raceway N N In riser optical fiber and communications raceway, and riser cable routing assemblies N N In general-purpose optical fiber and communications raceway, and general-purpose cable routing assemblies N N Page 13 of 21

14 What is the significance of this change? Cable routing assemblies are used to support and organize large quantities of optical fiber, communications and data cables in high density applications such as installations of IT and communications equipment. They are fabricated from plastic and that could be problematical if materials with inadequate fire resistance were used. The fire tests and test criteria used for listing cable routing assemblies are identical to those used for optical fiber and communications raceways. A plenum grade cable routing assembly was not proposed out of deference to NFPA 90A which has the primary requirements for combustible is plenums. Proposals to cover plenum grade cable routing assemblies have been submitted for NFPA 90A and are currently being processed. Restrictions on plenum cable in air ducts Sections (B), (B), (B) and (B) prohibit the placing of cables in air ducts unless the cable are directly associated with the air distribution system and then the length of cable is limited to 4 ft. What is the significance of these changes? The 2008 NEC permits Types OFNP, OFCP, CMP, CATVP and BLP cables to be installed in in ducts, plenums, and other spaces used for environmental air. Section of NFPA 90A states that Wiring shall not be installed in air ducts unless it is directly associated with the air distribution system and does not exceed 1.22m (4 ft). The changes in sections (B), (B), (B) and (B) were introduced in order to correlate with section of NFPA 90A. Restrictions on general-purpose cables in riser installations Sections (B)(1), (B)(1), (B)91), (B)(1) and (B)(1) in the 2008 NEC require riser rated cables for vertical runs of more than one floor, permitting general-purpose cable for penetrations of one floor only. These sections also require that Floor penetrations requiring riser or plenum cables shall contain only cables suitable for riser or plenum use. In the 2011 NEC sections (D), (D), (D) and (D) require riser or plenum cables for vertical runs penetrating one or more floors. Application Tables (a), (a), (a) and (a) all show that general-purpose cables are not permitted in risers. The applications of communications wires and cables, and optical fiber cables are shown in the tables below. See Table (a) in the 2011 NEC for a complete table showing the Applications of Listed Optical Fiber Cables and Raceways, and Cable Routing Assemblies in Buildings. See Table (a) for the comparable table for communications. The applications of CATV cables and network-powered broadband cables are shown in Tables (a) and (a) respectively. Page 14 of 21

15 Applications of Optical Fiber Cables Applications Cable Type OFNP, OFCP OFNR, OFCR OFNG, OFCG, OFN, OFC In Air Ducts In air ducts Y N N In metal raceway that complies with (B) Y Y Y In other spaces used for environmental air Y N N In metal raceway that complies with (C) Y Y Y In Other Spaces Used for Environmental Air (Ceiling Cavity, Raised Floor and Air-Handling Room Plenums) In plenum optical fiber and communications raceways Y N N Supported by open metal cable trays Y N N Supported by solid bottom metal cable trays with solid metal covers Y Y Y In vertical runs Y Y N In metal raceways Y Y Y In fireproof shafts Y Y Y In Risers In plenum optical fiber and communications raceways In riser optical fiber and communications raceways Y Y N Y Y N In riser cable routing assemblies Y Y N In one- and two-family dwellings Y Y Y General Y Y Y Supported by cable trays Y Y Y In distributing frames and cross connect arrays Y Y Y In any raceway recognized in Chapter 3 Y Y Y Within Buildings in other than Air-Handling Spaces and Risers In plenum optical fiber and communications raceway In riser optical fiber and communications raceway, and riser cable routing assemblies Y Y Y Y Y Y In general-purpose optical fiber and communications raceway, and general-purpose cable routing assemblies Y Y Y Page 15 of 21

16 Applications of Communications Wires and Cables Applications CMP CMR CMG CM Wire and Cable Type CMX CMUC Hybrid power & communications cables In Air Ducts In Other Spaces Used for Environmental Air (Ceiling Cavity, Raised Floor and Air-Handling Room Plenums) In air ducts Y N N N N N In metal raceway that complies with (B) Y Y Y Y N N In other spaces used for environmental air Y N N N N N In metal raceway that complies with (C) Y Y Y Y N N In plenum communications raceways Y N N N N N Supported by open metal cable trays Y N N N N N Supported by solid bottom metal cable trays with solid metal covers Y Y Y Y N N In vertical runs Y Y N N N N In metal raceways Y Y Y Y N N In fireproof shafts Y Y Y Y N N In Risers In plenum communications raceways Y Y N N N N In riser communications raceways Y Y N N N N In riser cable routing assemblies Y Y N N N N In one- and two-family dwellings Y Y Y Y N Y General Y Y Y Y N N In one- and two-family dwellings Y Y Y Y Y Y In multifamily dwellings Y Y Y Y Y N In nonconcealed spaces Y Y Y Y Y N Supported by cable trays Y Y Y N N N Within Buildings in Other Than Air- Handling Spaces and Risers Under carpet N N N N Y N In distributing frames and cross-connect arrays Y Y Y N N N In any raceway recognized in Chapter 3 Y Y Y Y N N In plenum communications raceways Y Y Y N N N In riser communications raceways and riser cable routing assemblies Y Y Y N N N In general-purpose communications raceways and general-purpose cable routing assemblies Y Y Y N N N Page 16 of 21

17 What is the significance of this change? Requiring riser cables (or plenum cables as substitutes) is a simplification. With general-purpose cable no longer being permitted, it is no longer necessary to have separate floor penetrations, one for riser and plenum cables and the other for general-purpose cables. The change still permits generalpurpose cables to be used in vertical runs in metal raceways or in fireproof shafts. Revision of Applications Sections The text of applications sections of Articles 770, 800, 820 and 830 in the 2008 NEC ( , , and ) cover the applications of cables and raceways, and, notwithstanding the fact that the title of the sections is applications, contain numerous installation rules. In the 2011 NEC, installation rules have been moved out to the installation sections ( , , and ). The applications are now covered in tables (Tables (a), (a), (a) and (a)). A note at the bottom of each table explains that An N in the table indicates that the cable type is not permitted to be installed in the application. A Y* indicates that the cable is permitted to be installed in the application, subject to the limitations of the installation section. The NEC uses a Y* rather than a Y to emphasize that permitted applications are subject to the limitations of installation rules. No asterisk is needed for the prohibited applications indicated by an N because the concept of no is simple. Please view Tables (a), (a), (a) and (a) in the 2011 NEC. What is the significance of these changes? The text in sections , , and in the 2008 NEC contains a mixture of applications and installation rules. Nearly all of the application statements are positive statements of where a cable, for example, is permitted to be used. Rarely do these sections state the prohibited applications, leaving to the user to infer the prohibited applications. For example, (C)(6) states that undercarpet cable is permitted to be installed under carpet, with no indication of any other permitted uses or prohibited uses. The new tables clearly indicate the prohibited applications with an N. See Table (a) or the above table to see the many prohibited applications of undercarpet cable. Revision of Cable Installation Rules While sections , and (Installation) in the 2008 NEC, are purported to cover installation of cables in their titles, they only required that listed cables be installed in buildings. In the 2011 NEC these sections have been greatly expanded to cover the installation of cables, wires, raceways, cable routing assemblies, and to also cover which cables are permitted to be installed in raceways, cable trays and routing assemblies in a variety of environments including air ducts, plenums, risers, general building spaces and in dwellings, one- ant two-family and multifamily dwellings. These sections are quite long and detailed. Please view sections , , and in the 2008 and 2011 NEC. Page 17 of 21

18 What is the significance of these changes? The expansion of sections , , and to provide detailed installation rules was done for two reasons, first, the removal of installation rules from the applications sections required that the installation rules be moved to the appropriate place, and second, expanding the detail of the installation rules greatly improved clarity. Cable Ties and Mechanical Execution of Work Sections , , and (Mechanical Execution of Work), all have a new informational note referencing NFPA 90A for testing discrete components installed in air ducts and other spaces used for environmental air, (plenums). What is the significance of this change? The mechanical execution of work sections require that cables shall be secured by hardware including straps, staples, cable ties, hangers, or similar fittings. There are no requirements for listing these support hardware in the NEC, but NFPA 90A-2009 has heat release and smoke emissions requirements for cable ties, and other discrete products in sections (ceiling cavity plenums) and (raised floor plenums). Annex note A provides guidance listing of testing of cable ties. The new informational note refers to NFPA 90A-2009 for discrete combustible components installed in (B) and (C) spaces. The spaces in (C) are other spaces used for environmental air that translate into ceiling cavity and raised floor plenums in NFPA 90A. The spaces in (B) translate into air ducts in NFPA 90A. There are no requirements for discrete combustible products in air ducts in NFPA 90A Underground Communications Cables Entering Buildings Section , which deals with separation requirements between communications cables and power cables, has a new statement that (C) shall not apply to communications wires and cables. Section (C) requires that cables in a wet location be listed for use in wet locations. What is the significance of this change? Under the provisions of section 90.3, Chapter 8 is independent of Chapters 1 through 7; section (C) does not apply to Article 800 unless it is specifically referenced, which it is not. The statement that (C) does not apply was added for emphasis since some inspectors are nonetheless demanding wet rated telephone cable. The telephone cable that enters buildings underground is unlisted outside plant cable. It is designed to be buried in the earth, but it can t have a wet rating because it is unlisted. Page 18 of 21

19 ARTICLE 840 Premises-Powered Broadband Communications Systems Article 840 is a new article in the 2011 NEC. Unlike Article 830, which covers Network- Powered Broadband Communications, Article 840 covers Premised-Powered Broadband Communications. The Scope states that these systems provide voice, video, data, and interactive services through an optical network terminal (ONT). The Article provides for the installation of the ONT, and just like Article 830, it refers to other articles for the output circuits of the ONT. Output Circuit Applicable Article Class 2 and Class Fire alarm 760 Optical fiber 770 Communications 800 Cable TV 820 What is the significance of this change? Article 840 was created to accommodate FiOS (fiber optic service), which brings an optical fiber to the customer premises and derives telephone, television and internet service through an ONT. Creation of a new article was necessary because the scope of Article 770, Optical Fiber Cables and Raceways, only covers the installation of optical fiber cables, raceways, and cable routing assemblies, consequently the installation requirements for the ONT could not be inserted into Article 770. Use of Article 800 was a possibility, but Article 800 defers to Article 770 for optical fiber cable installation. Please read Article 840 in the 2011 NEC. Page 19 of 21

20 Raceways ARTICLE 725 Class 1, Class 2, and Class 3 Remote-Control, Signaling, and Power-Limited Circuits & ARTICLE 760 Fire Alarm Systems Sections 725.3(H) and 760.3(H) in the 2011 NEC require raceways exposed to different temperatures to comply with 300.7(A). Section 300.7(A) requires that raceways that are subjected to different temperatures, as for example raceways passing through a refrigerated area of a building, be sealed to prevent the circulation of warm air and the subsequent condensation. Sections 725.3(J) and 760.3(J) require bushings to be installed on the ends of raceways to protect them from abrasion. Section 760.3(J) requires fire alarm cables installed in raceways to comply with raceway fill requirements. What is the significance of these changes? Articles 725 and 760 exempt themselves from the provisions of Article 300 Wiring Methods except from those sections that are specifically referenced. The result of these new requirements is that 300.7(A) which deals with raceway sealing, and (C) which deals with abrasion protection of cables emerging from raceway, now apply to data (class 2) and fire alarm cables. They already apply to communications and optical fiber cables because and require that raceways recognized in Chapter 3 be installed in accordance with Chapter 3. Now that raceway fill requirements to fire alarm cables, fire alarm cables have a requirement that is not applied to data cables, optical fiber cables and communications cables. Section (D) permits communications cables to substitute for powerlimited fire alarm cables, but the wiring rules for fire alarm cables still apply. Consequently, communications cables that are being used for fire alarm circuits are subject to the raceway fill requirements while the same cables installed in raceway for communications purposes are not subject to raceway fill requirements. Page 20 of 21

21 Prepared by Stanley Kaufman, Ph.D. CableSafe, Inc. Member of NEC Panels 12 and 16 November 4, 2010 This paper, provided by the Communication Cable and Connectivity Association, Inc. ("CCCA"), is offered for general information and educational purposes. It is not offered, intended, nor should it be relied upon as legal advice. The paper is a publication of the CCCA, and does not set forth the views of any member or any other party, nor may it be taken as such. CCCA makes no warranty regarding the accuracy of the information provided in this paper, and expressly disclaims any implied warranties and any liability for use of the paper or reliance on views expressed in it. CCCA does not endorse, approve, or certify any information set forth in this paper, nor does it guarantee the accuracy, completeness, efficacy, timeliness, or correct sequencing of such information. Use of the paper and the views expressed in it is voluntary, and reliance on it should only be undertaken after an independent review of its accuracy, completeness, efficacy, and timeliness, and based on the individual facts and circumstances of a user. Copyright CCCA. All rights reserved. Page 21 of 21

Errata NFPA 70. Proposed 2014 Edition

Errata NFPA 70. Proposed 2014 Edition Errata NFPA 70 National Electrical Code (Report on Proposals) Reference: 12-109 (Log #1618) Panel Meeting Action Proposed 2014 Edition The National Electrical Code Technical Correlating Committee notes

More information

800 Communications Circuits

800 Communications Circuits ARTICLE 800 Communications Circuits INTRODUCTION TO ARTICLE 800 COMMUNICATIONS CIRCUITS This article has its roots in telephone technology. Consequently, it addresses telephone and related systems that

More information

SUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND

SUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND Belden Electronics Division P.O. Box 1980 Richmond, Indiana 47375-1980 2200 U.S. Highway 27 South Richmond, Indiana 47374-7279 Telephone: 765 983 5200 Facsimile: 765 983 5825 SUBJECT: NO MORE 300 VOLTS

More information

How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System

How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System July 28, 2003 We are pleased to provide the following joint statement by CII,

More information

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. 1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking

More information

WHITE PAPER Fire & safety performance standards

WHITE PAPER Fire & safety performance standards WHITE PAPER Fire & safety performance standards Terminologies describing Fire Performance Terminologies describing Fire Performance often present a challenge to understand as how they apply to a cable

More information

The most important matter is to select the right product based on the environment in which it will be installed and on its use or application.

The most important matter is to select the right product based on the environment in which it will be installed and on its use or application. Communication cables and burning behaviour international regulations Different regulations and standards apply depending on the geographic location. Europe is normally governed by CENELEC (EN), but in

More information

Electrical Code (NEC) Snake Tray Cable Management Solutions

Electrical Code (NEC) Snake Tray Cable Management Solutions Cable Pathway Use and Selection and the National Electrical Code (NEC) By Eric J. Sadler, BSME MIT Snake Tray Cable Management Solutions References: All references to the NEC in this presentation are taken

More information

Understanding Emergency Power Off (EPO)

Understanding Emergency Power Off (EPO) Understanding Emergency Power Off (EPO) White Paper #22 Executive Summary Emergency Power Off (EPO) is the capability to power down a piece of electronic equipment or an entire installation from a single

More information

DPS Preliminary Review: Verizon FIOS Customer Premises Installation NEC Compliance Issues

DPS Preliminary Review: Verizon FIOS Customer Premises Installation NEC Compliance Issues DPS Preliminary Review: Verizon FIOS Customer Premises Installation NEC Compliance Issues OVERVIEW A key aspect of providing telecommunications services is the provision of those services in a safe and

More information

Safety & Performance in the Wire and Cable Industry

Safety & Performance in the Wire and Cable Industry Safety & Performance in the Listed vs. Verified: Marks, Logos and Programs Written by: Antoine Pelletier, Team Leader, Global Cabling Products Larry Todd, Chief Engineer Intertek icenter@intertek.com 1-800-WORLDLAB

More information

Fire Life Safety ORC Review Guidelines for PPD Experimental Installations

Fire Life Safety ORC Review Guidelines for PPD Experimental Installations Fire Life Safety ORC Review Guidelines for PPD Experimental Installations Fire Protection Review for the Fixed Target ES&H Review Committee September 2010 By James Priest PhD DRAFT Overview: When reviewing

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-27 05 14.00 10 (April 2006) -------------------------------- Preparing Activity: USACE Superseding UFGS-27 05 14.00 10 (April 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 105.8a-6.1 TITLE: FIRE ALARM SYSTEM REQUIREMENTS SCOPE: This guideline

More information

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders INTRODUCTORY INFORMATION TABLE OF CONTENTS 00 0101 PROJECT TITLE PAGE PROCUREMENT REQUIREMENTS (PROJECT MANUAL) Tab A - Invitation for Bids Tab B - Instructions to Bidders Tab C Bid Form for General Bids

More information

Engineers Edge, LLC PDH & Professional Training

Engineers Edge, LLC PDH & Professional Training 510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 Engineers Edge, LLC PDH & Professional Training Copyright, All Rights Reserved Engineers Edge, LLC An Introduction to Communication

More information

SECTION 17400 ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.

SECTION 17400 ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section. SECTION 17400 ACCESS CONTROL SYSTEM CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section. PART 1 - GENERAL 1.1 RELATED WORK A. 16060 Grounding and Bonding B. 16070 Electrical

More information

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST Name of School: OPTIONAL INFORMATION Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST Guidelines: This checklist

More information

Limited Combustible: The New Standard for Fire Safety

Limited Combustible: The New Standard for Fire Safety Limited Combustible: The New Standard for Fire Safety Written by Daniel Kennefick Limited Combustible Product Business Manager Berk-Tek, A Nexans Company Since the advent of client server computing in

More information

FIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager

FIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager FIRE RATED WIRING What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager INTRODUCTION OBC requirements for emergency power OBC requirements for emergency power for fire alarm systems and other building

More information

Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port

Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port Code-Wide Code Change Section 90.5(C). Fine Print Notes are now referred to as "Informational Notes." The purpose, intent,

More information

Excerpts from the Canadian National Building Code (NBC)

Excerpts from the Canadian National Building Code (NBC) Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more

More information

PLAN REVIEW GUIDE FOR FIRE ALARM

PLAN REVIEW GUIDE FOR FIRE ALARM PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical

More information

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013 Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems April 2013 The National Multi Housing Council and the National Apartment Association (NMHC/NAA) have

More information

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems

More information

Click here to see a video example of cable being burned outside the controlled lab environment. UL-910 Test for Flame-Propagation and Smoke Density

Click here to see a video example of cable being burned outside the controlled lab environment. UL-910 Test for Flame-Propagation and Smoke Density Plenum (CMP) Rated Cable Often found on building material lists, the Plenum rating (CMP) signifies cable that has passed stringent burn testing and is suitable for installation into Air Plenum spaces.

More information

DUCT SYSTEMS CHAPTER 6

DUCT SYSTEMS CHAPTER 6 CHAPTER 6 DUCT SYSTEMS SECTION 601 GENERAL 601.1 Scope. Duct systems used for the movement of air in air-conditioning, heating, ventilating and exhaust systems shall conform to the provisions of this chapter

More information

Fire Performance Standard

Fire Performance Standard Fire Performance Standard At present, in cable industry, Fire Retardant, Low Smoke Halogen Free (LSZH), Low Smoke Fume (LSF) and Fire Resistant cables are all described as Fire survival Cables. Flame Retardant

More information

Solar Panel Installations

Solar Panel Installations Solar Panel Installations Page 1 of 6 SINGLE-FAMILY RESIDENTIAL CHECKLIST City of Hayward Development Services Department Revised: 7-09-15 PERMIT REQUIREMENTS Permits are required for all solar panel installations.

More information

Overview of Standards for CO Detection Products

Overview of Standards for CO Detection Products Overview of Standards for CO Detection Products Rev 1.1 INTEC Controls 12700 Stowe Dr., Suite 100 Poway, CA 92064 The Right Choice info@inteccontrols.com www.inteccontrols.com Phone: (858) 578-7887 Fax:

More information

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS NOTICE TO BIDDERS BID FORM INSTRUCTIONS TO BIDDERS CONTRACTOR S BID FOR PUBLIC WORK - FORM 96 MINORITY AND WOMEN S BUSINESS ENTERPRISE PARTICIPATION

More information

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+)

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+) Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+) 1. In addition to the information scheduled below, the pre-tender designer is responsible for: (i)

More information

Australian/New Zealand Standard

Australian/New Zealand Standard Australian/New Zealand Standard The use of ventilation and air conditioning in buildings - Part 1: Fire and smoke control in buildings UPDATED AS/NZS 1668.1:2015 What is the scope of this Standard? The

More information

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS 527 CMR 31.00: CARBON MONOXIDE ALARMS Section 31.01: Purpose and Scope 31.02: Definitions 31.03: General Installation Provisions 31.04: Specific Installation Provisions 31.05: Carbon Monoxide Protection:

More information

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE 1999 2002

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE 1999 2002 CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE 1999 2002 Three new chapters were added. What was chapter 1 in 1999 was reorganized into chapters 1 (Fundamentals), 2 (Referenced Publications), and 3 (Definitions).

More information

SECTION 00 0110 TABLE OF CONTENTS. H. 00 2115.01 - Proposed Material, Product or Equipment Substitution Request

SECTION 00 0110 TABLE OF CONTENTS. H. 00 2115.01 - Proposed Material, Product or Equipment Substitution Request SECTION 00 0110 PROCUREMENT AND CONTRACTING REQUIREMENTS 1.1 DIVISION 00 -- PROCUREMENT AND CONTRACTING REQUIREMENTS A. 00 0101 - Project Title Page B. 00 0105 - Certifications Page C. 00 0110 - Table

More information

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting

More information

Table of Contents. Foreword... iii. About the Author... iv. Unit 1. Introduction... 1. Unit 2. NEC Introduction [Article 90]... 10

Table of Contents. Foreword... iii. About the Author... iv. Unit 1. Introduction... 1. Unit 2. NEC Introduction [Article 90]... 10 Table of Contents Foreword........................................................... iii About the Author..................................................... iv Unit 1. Introduction..........................................................

More information

CHAPTER 6 DUCT SYSTEMS

CHAPTER 6 DUCT SYSTEMS CHAPTER 6 DUCT SYSTEMS SECTION MC 601 GENERAL 601.1 Scope. Duct systems used for the movement of air in air-conditioning, heating, ventilating and exhaust systems shall conform to the provisions of this

More information

2301.1 Scope: Communications and Electronic Systems addressed in this section include:

2301.1 Scope: Communications and Electronic Systems addressed in this section include: Chapter 23 COMMUNICATIONS / ELECTRONIC SYSTEMS SECTION 2301 - GENERAL 2301.1 Scope: Communications and Electronic Systems addressed in this section include: 1. Fire Alarm System 2. Telecommunication and

More information

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute Cable Tray Wiring Systems Have Many Cost Advantages Cost is usually a major consideration in the selection of a wiring system.

More information

REFERENCE STANDARD RS 13 MECHANICAL VENTILATION, AIR CONDITIONING, AND REFRIGERATION SYSTEMS * LIST OF REFERENCED NATIONAL STANDARDS

REFERENCE STANDARD RS 13 MECHANICAL VENTILATION, AIR CONDITIONING, AND REFRIGERATION SYSTEMS * LIST OF REFERENCED NATIONAL STANDARDS REFERENCE STANDARD RS 13 MECHANICAL VENTILATION, AIR CONDITIONING, AND REFRIGERATION SYSTEMS * LIST OF REFERENCED NATIONAL STANDARDS **NFiPA 90A Standard for the Installation of Air Conditioning and Ventilating

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 City of Cotati Building Division 201 W. Sierra Ave. Cotati, CA 94931 707 665-3637 Fax 792-4604 INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 Any PV system on a new structures should be included

More information

Fire Alarm System Plans Review Checklist Property location Date of Review

Fire Alarm System Plans Review Checklist Property location Date of Review Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include

More information

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval. Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's

More information

WHY CABLE TRAY? BECAUSE A CABLE TRAY WIRING SYSTEM PROVIDES SAFE AND DEPENDABLE WAYS TO SAVE NOW AND LATER

WHY CABLE TRAY? BECAUSE A CABLE TRAY WIRING SYSTEM PROVIDES SAFE AND DEPENDABLE WAYS TO SAVE NOW AND LATER Large numbers of electrical engineers have limited detail knowledge concerning wiring systems. There is the tendency by engineers to avoid becoming involved in the details of wiring systems, leaving the

More information

Effective June 27, 2015. TEXT (CO Detection Commercial Buildings)

Effective June 27, 2015. TEXT (CO Detection Commercial Buildings) TEXT (CO Detection Commercial Buildings) Part 1228 of Title 19 NYCRR is amended by adding a new section 1228.4, to read as follows: Section 1228.4. Carbon Monoxide Detection in Commercial Buildings (a)

More information

Colorado Army National Guard Grand Junction Readiness Center NGB PN 080204 Coover-Clark & Associates CCA Job No. 0726

Colorado Army National Guard Grand Junction Readiness Center NGB PN 080204 Coover-Clark & Associates CCA Job No. 0726 SECTION 260523 - CONTROL-VOLTAGE ELECTRICAL POWER CABLES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. UTP cabling. 2. RS-232 cabling. 3. RS-485 cabling. 4. Low-voltage control cabling. 5. Control-circuit

More information

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing

More information

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems Fire Alarm System Plans Submittal Guidelines For New and Existing Systems SCOPE The Temecula Fire Prevention Bureau (TFPB) has established the following requirements for the submittal of all fire alarms,

More information

TEXT (CO Detection Commercial Buildings Final) Part 1228 of Title 19 NYCRR is amended by adding a new section 1228.4, to read as follows:

TEXT (CO Detection Commercial Buildings Final) Part 1228 of Title 19 NYCRR is amended by adding a new section 1228.4, to read as follows: TEXT (CO Detection Commercial Buildings Final) Part 1228 of Title 19 NYCRR is amended by adding a new section 1228.4, to read as follows: Section 1228.4. Carbon Monoxide Detection in Commercial Buildings

More information

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS I. APPLICATION AND DEFINITIONS 1.01 Authorization for Standards 1.02 Application of Standards 1.03 Definitions

More information

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes 2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes 1) Tamper resistant receptacles. 2009 CEC Required in dwelling units 2012 CEC Expanded to child care facilities First introduced in the 2009

More information

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 PART 1 - GENERAL 1.01 WORK INCLUDED FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 A. Provide a complete fully addressable, power limited, fire detection and evacuation system. The system shall be connected

More information

How To Install A Carbon Monoxide Detector

How To Install A Carbon Monoxide Detector NASSAU COUNTY FIRE COMMISSION OFFICE OF THE FIRE MARSHAL Nassau County Public Safety Center 1194 Prospect Avenue Westbury, New York 11590 (516) 573-9900 / nassaucountyny.gov Chief Fire Marshal Scott D.

More information

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 PART 1 - GENERAL 1.01 RELATED DOCUMENTS: SECTION 16050 A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1

More information

FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY

FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Addressable interface

More information

Top Commercial / Residential Electrical Requirements *

Top Commercial / Residential Electrical Requirements * Department of Community Development Building Division 4800 West 92 nd Avenue Westminster, Colorado 80031 For Information call (303) 658-2075 Fax (303) 706-3922 www.westminsterpermits.com Top Commercial

More information

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems Content Introduction Preventing unauthorized access by perimeter surveillance Monitoring unauthorized access by indoor surveillance

More information

ENGINEERING COMMITTEE Energy Management Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 210 2015

ENGINEERING COMMITTEE Energy Management Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 210 2015 ENGINEERING COMMITTEE Energy Management Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 210 2015 Performance Metrics for Energy Efficiency & Functional Density of Cable Data Generation, Storage, Routing,

More information

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such

More information

Tremco Fire Protection Systems Group Technical Bulletin

Tremco Fire Protection Systems Group Technical Bulletin Compartmentalization products and design play a key role in protecting lives and property from fire. Understanding the tools and techniques available for firestopping is of utmost importance to designers,

More information

Original Document 10/16/07 Revised 01/30/09 2 nd Revision 01-23-12 3 rd Revision- 12/18/14

Original Document 10/16/07 Revised 01/30/09 2 nd Revision 01-23-12 3 rd Revision- 12/18/14 North Collier Fire Control & Rescue District Greater Naples Fire Rescue District Immokalee Fire Control & Rescue District 2800 North Horseshoe Drive Naples, Florida 34104 SYSTEM REHABILITATION PLAN CHECKLIST

More information

ELECTRICAL INSPECTION BULLETIN (Effective 2000-03-01)

ELECTRICAL INSPECTION BULLETIN (Effective 2000-03-01) ELECTRICAL INSPECTION BULLETIN (Effective 2000-03-01) Rule 28-900 Standby Generator Installations Due to the increasing number of standby generator installations being established to maintain continuity

More information

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors. September 14, 2012 Dear AMM Member: Please see the attached Fire Code Frequently Asked Questions. This document was compiled by the Office of the Fire Commissioner at the AMM s request to help clarify

More information

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property 2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical

More information

Electrical Contractors. and the. New Jersey. Rehabilitation Code

Electrical Contractors. and the. New Jersey. Rehabilitation Code Electrical Contractors and the New Jersey Rehabilitation Code Alan Chech Electrical Seminars 609-890-7072 www.alanchech.com Information is based on the presently adopted electrical subcode NEC 2005. Current

More information

General Fire Code Requirements Within Commercial Tenant Spaces

General Fire Code Requirements Within Commercial Tenant Spaces FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding

More information

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Fire. The Fire Installers Mate. A guide to fire alarm systems design Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects

More information

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264 BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used

More information

Fire Pump Plan Review March 2010

Fire Pump Plan Review March 2010 Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:

More information

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems 1.0 Purpose A. The following guideline provides the minimum standards and requirements for fire alarm systems. 2.0

More information

The Pennsylvania State University ------------- Physical Security Office. Intrusion Alarm. Performance Specification

The Pennsylvania State University ------------- Physical Security Office. Intrusion Alarm. Performance Specification The Pennsylvania State University ------------- Physical Security Office Intrusion Alarm Performance Specification By PHYSICAL SECURITY OFFICE Group (Access Controls & Electronic Security Programs) and

More information

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT FIRE EXTINGUISHERS,SPRINKLER SYSTEMS AND FIRE ALARMS Attachment #1 Inspection of Fire Extinguishers Fire Extinguishers must be tested according

More information

CAN/ULC-S524-06 Installation of Fire Alarm Systems Amendment 1. Canadian Fire Alarm Association (CFAA) D. GOODYEAR FIRE CONSULTING

CAN/ULC-S524-06 Installation of Fire Alarm Systems Amendment 1. Canadian Fire Alarm Association (CFAA) D. GOODYEAR FIRE CONSULTING CAN/ULC-S524-06 Installation of Fire Alarm Systems Amendment 1 Canadian Fire Alarm Association (CFAA) CAN/ULC-S524 AMENDMENT 1 PUBLISHED February 2011 WHY Clarifications New requirements (Technology changes)

More information

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation Data Center Pre-terminated Patch Panel System Patch Panels Plug & Play Installation 10G + Gigabit Patch Cords Bundled + Labeled Cabling Systems Simplified Our Mission At Cablesys, our mission is to simplify

More information

ARE YOU IN COMPLIANCE WITH THE OSHA COMBUSTIBLE DUST DIRECTIVE? Revised March 18, 2009

ARE YOU IN COMPLIANCE WITH THE OSHA COMBUSTIBLE DUST DIRECTIVE? Revised March 18, 2009 Kidde Fenwal, Inc. Industrial Explosion Protection Group A UTC Fire & Security Company 400 Main Street Ashland, MA 01721 Tel 508-881-2000 Fax 508-485-3115 www.fenwalprotection.com FENWAL Protection Systems

More information

University Design Standard. Fire Alarm Systems

University Design Standard. Fire Alarm Systems University Design Standard Fire Alarm Systems 1.0 Overview This document provides Virginia Tech s standards for the design and installation of fire alarm systems and equipment in new construction, retrofit

More information

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and

More information

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective The National Fire Alarm Code, NFPA 72, sets the minimum requirements of performance, selection, use and location of automatic detection

More information

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS A. SCOPE 1. This information is intended to assist contractors, installers and code officials in the proper design and installation of flexible

More information

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011 Office of the Fire Marshal 1.0 PERMITS FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011 1.1 To acquire an installation

More information

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist #506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist Case #: Date: Project Name: Site Address: Application Submittal Building permit applications and plans can be submitted to the

More information

How To Buy Honeywell Genesis Series Fire Alarm Cables

How To Buy Honeywell Genesis Series Fire Alarm Cables Fire Wire Genesis Series Cables for Fire-Lite Alarms We've Got a Cable for That! Genesis Series Cables for Firelite DIRECTORY ANN-BUS... 2 Signaling Line Circuits (SLC)... 3 Conventional 2&4 Wire Initiating

More information

Code Compliance for Spring Steel Fasteners Based on the 2005 NEC

Code Compliance for Spring Steel Fasteners Based on the 2005 NEC Code Compliance for Spring Steel Fasteners Based on the 2005 NEC B-Line has recognized the need for a reference source, detailing the National Electrical Code requirements for Spring Steel Fasteners. The

More information

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range HONEYWELL SECURITY & CUSTOM ELECTRONICS Cable Products Honeywell's Genesis Series provides a full range of low voltage cables for security, fire, sound, voice and data, video, structured cabling and other

More information

AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY. (The following code explanations are to be used with a copy of the 2011 NEC.

AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY. (The following code explanations are to be used with a copy of the 2011 NEC. AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY (The following code explanations are to be used with a copy of the 2011 NEC.) To obtain a copy of the NEC contact: National Fire Protection Association

More information

4 Installation Requirements

4 Installation Requirements 4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming

More information

The Mission Critical Fire Protection Experts

The Mission Critical Fire Protection Experts The Mission Critical Fire Protection Experts Protection Systems Protection Systems HFC-227ea / FM200 / FE-227 FE-25 / ECARO-25 Novec 1230 Inergen / Argonite Halon Drop-in Systems High and Low Pressure

More information

Bold items are particular to the City of Euless

Bold items are particular to the City of Euless EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 2/12 Fire Chief Wes Rhodes Fire Marshal Paul Smith EFD-FMO 3-2 2009 International Fire & Building Code as Amended NFPA Standards Adopted

More information

Building Code Clarifications - 7. Fire Resistance

Building Code Clarifications - 7. Fire Resistance Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,

More information

Name Of Occupancy Date. Yes No Describe

Name Of Occupancy Date. Yes No Describe FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address

More information

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment. SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

Building Codes Update: The 2009 International Fire Code and the Apartment Industry ! Building Codes Update: The 2009 International Fire Code and the Apartment Industry Apartment operators and developers should be aware of organizational changes in the 2009 edition of the International

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information