1 HVAC Control & Balancing Dampers Models VCD, MBD and RBD Selection Construction Performance H* W* August

2 HVAC Control and Balancing Dampers Commercial Control Dampers are used in buildings to regulate the flow of air in an HVAC system. They can be used in intake, exhaust, or mixed air applications. There are two categories of control dampers: Balancing Commercial Control Balancing Manual balancing dampers are control dampers that regulate the flow of air but are not intended to be used in applications as a positive shut-off or for automatic control. These dampers are shipped with manual hand quadrants that can be locked in place. There are four balancing damper models available: MBD-10/10M is a single blade MBD-15 is a multi-blade MBDR-50 is a round blade Remote balancing dampers offer the same function as a manual balancing damper plus the added benefit of controlling the damper remotely at a diffuser or wall plate. These remote balancing dampers are ideal for applications where it is difficult to gain access to manually adjust the dampers to balance airflow. The EZ Balance remote control operates the damper motor by connecting to the wall, ceiling, or diffuser mounted RJ11 connector. There are two remote balancing damper models available: RBD-10 (single blade) RBDR-50 (round blade) MBD-10 Single blade * shown with optional standoff bracket MBD-15 Multi-blade Meets SMACNA recommended construction requirements MBDR-50 Round blade RBD-10 Single blade * Actuator shipped as a kit for field installation RBDR-50 Round blade Factory-mounted actuator 2

3 Manual and Remote Balancing Dampers A wide variety of accessories are available for the RBD and RBDR series. They include: Diffuser connector Wall plates with ports Round wall/ceiling plate with single port Single gang outlet box EZ Balance handheld remote kit Plenum and non-plenum rated cables Cable connectors Quick Selection Chart EZ Balance handheld remote kit MBD-10 MBD-10M MBD-15 MBDR-50 RBD-10 RBDR-50 Single Blade X X X Blade Profile 3V X Round X X Material Galvanized X X X X X X Frame Gauge 20 (1) X X 18 (1.3) X X X 16 (1.5) X Bearings Synthetic X X X X Bronze O Axles Steel X X X Linkage Material Steel X Actuator Sizing Inches (mm) Manual Quadrant X X X X 1-1/2 in. Standoff Bracket O O X O 2 in. Standoff Bracket O O O O Remote Powered 9 Volt Actuator Minimum Maximum Single Section Maximum Multi-Section 6 x 4 (152 x 102) 36 x 12 (914 x 305) 8 x 4 (203 x 102) 36 x 12 (914 x 305) x 6 (152 x 152) 48 x 60 (1219 x 1524) 96 x 96 (2438 x 2438) 4 (102) 24 (610) X 6 x 4 (152 x 102) 36 x 12 (914 x 305) X 4 (102) 24 (610) X = Standard O = Optional Pressure RBD-10 RBD-10 RBDR-50 RBDR-50 MBD-10/10M MBD-15 MBDR Feet per Minute (maximum) MBD-10/10M MBD-15 MBDR Inches wg (maximum) 3

4 Volume Control Dampers VCD Series Commercial Control Commercial control dampers regulate the flow of air in the same manner as manual balancing dampers, in addition, they can be used as a positive shutoff or for automatic control. There are three types of commercial control dampers available: Volume control VCD series Insulated control ICD series Air measuring control - AMD series Blade Manual Quadrant Kit Bearing Shaft Extension Jamb Seal Axle Blade Seal Frame Linkage Variable Symmetric Blade Design (VSB) Part of Greenheck s unique approach to damper construction, Variable Symmetric Blade design (VSB), uses two principles to increase damper performance. First, all damper blades are symmetric about their axis. Second, any combination of 4, 5, 6, and 7 in. (102, 127, 152, and 178mm) blade widths are used in a single damper. These two features are part of Greenheck s standard construction and provide the following advantages: Free Area Free Area Increases Mounting Flexibility - Symmetrical blades have identical operating characteristics regardless of airflow direction. This allows a Greenheck control damper to be mounted in either direction of flow, an advantage when installing with space constraints. Increases Free Area - Traditional damper designs with a single blade width require oversized blade stops, limiting free area when the blades are open (Figure 1). Greenheck is able to reduce height or eliminate blade stops, which maximizes free area and increases damper performance (Figure 2). Reduces Actuator Torque - If an unsymmetrical blade closes against airflow, a large amount of torque is needed because the air distribution is unbalanced. Greenheck s VSB design balances airflow on each side of a symmetrical blade, reducing the torque required to operate the damper. The use of symmetrical blades allows Greenheck to reduce the size and quantity of actuators used on dampers (Figure 3). Competitor Airflow works against actuator Actuator Torque Unbalanced Blade Requires Higher Torque Greenheck with low profile frame Figure 1 Figure 2 Figure 3 Airflow works against actuator Airflow works with actuator Actuator Torque Balanced Blade Requires Less Torque 4

5 Design and Construction Features Blades 3V blades are fabricated from a single thickness of 16 ga. (1.5mm) galvanized or stainless steel, incorporating three longitudinal V-Type grooves running the full length of the blade to increase strength. This blade is standard on models VCD-15, 18, 20, 20V, 23, 23V, and SEVCD-23, designed for low to medium velocity and pressure applications. Airfoil blades are constructed of double-skin galvanized steel, stainless steel, or heavy-gauge extruded aluminum. This blade design results in lower resistance to airflow and increased strength that is typically used in high pressure systems. Airfoil blades are standard on models VCD-33, 33V, 34, 40, 42, 42V, 43, 43V and SEVCD-33. 3V Blade Steel Airfoil Blade Aluminum Airfoil Blade Parallel Versus Opposed Blade Operation Greenheck control dampers are offered with either parallel or opposed blades. Each style has distinguishing characteristics in regard to the type of operation required. Parallel blade operation - This configuration requires the damper blades to rotate in the same direction, parallel to one another. Parallel blade orientation is typically used when the damper operates in two positions, open or closed. Opposed blade operation - Adjacent damper blades rotate opposite one another under opposed blade configuration. Opposed blade configuration is typically used on dampers that modulate airflow. Parallel Blades Opposed Blades Frame Greenheck control dampers utilize a 5 in. x 1 in. (127mm x 25mm) hat channel frame made of 16 ga. (1.5mm) steel, 16 ga. (1.5mm) stainless steel, or in. (3mm) aluminum. Each frame is built with four separate pieces of material and joined by our Tog-L-Loc process resulting in the following advantages: Rigid frame - When two pieces of 16 ga. (1.5mm) steel are joined by the Tog-L-Loc system, the joint has an equivalent thickness of 10 ga. (3.5mm) steel. Increased corrosion resistance - High temperatures from welding remove the galvanized finish from damper frames. The Tog-L-Loc process does not use heat, so Greenheck damper frames have greater corrosion resistance by retaining the galvanized coating. Tog-L-Loc Reinforced Corner Optimal free area - On dampers that are 17 in. (432mm) high or less, Greenheck uses a low profile top and bottom frame section to maximize free area. Square frame - Many damper manufacturers construct each frame from a single piece of sheet metal, formed into shape by bending at three corners and spot welding in one. This type of construction can produce weak corners that are not necessarily 90º, resulting in a frame that is out-of-square. Symptoms of out-of-square frames include blades that do not close properly and reduced leakage performance. Using four separate frame components (top, bottom, and two sides), Greenheck s Tog-L-Loc process results in four sturdy, 90º joints. This ensures that each Greenheck damper is square and provides optimum performance in the field. There are five frame options available: Channel Frame (standard) Single Flange Single Reverse Flange Double Flange Quick Connect (VCD-43, -43V; ICD Series) Standard Frame Single Flange (actuator side) Single Reverse Flange (opposite actuator) Double Flange Quick Connect 5

6 Design and Construction Features Frame Options The channel frame style allows a damper to be insert mounted into an opening without being concerned about the linkage sticking out past the frame. The single and single reverse flange frame can be insert mounted or directly mounted to the wall, mating surface or bulkhead. The quick connect frame design is extruded to match up to a TDC, TDF, or Ductmate connection to allow the damper to be cleated to the ductwork. This illustration depicts how to mount a damper into a plenum wall. Linkage Traditional damper linkages are found in the airstream, adding to the pressure drop of the damper blades and frame. Greenheck control dampers have blade linkages concealed in the frame to prevent additional pressure drop and unwanted noise. With standard plated steel construction (stainless steel optional), the linkage is engineered to accurately control each and every blade without need for adjustment. No Top or Bottom Greenheck s standard control dampers are designed for installation in any position with the blades horizontal. The damper can be turned over so the actuator is on the left or right side. Optional vertical blade models can be turned with the actuator at the top or bottom. Standard Vertical Blade Multi-Section Dampers Each of Greenheck s VCD control dampers have a maximum size for a single damper section or panel. These sections vary from 48 in. wide x 60 in. high (1219mm x 1524mm) to 60 in. wide x 74 in. high (1524mm x 1880mm). Dampers larger than a single section will be made up of equal size sections which, depending upon model and size, may be shipped as a single complete assembly or as separate sections for field assembly. Multi-section damper assemblies are supplied with a coupler or factory installed jackshaft so all sections operate together. Factory Installed Jackshaft Coupled (concealed between frames) Damper assemblies (larger than one section) are not designed to be structurally self-supporting. Additional horizontal bracing is recommended for support. Vertical bracing should be installed if required to hold against system pressure. 6

7 Options and Accessories QR Codes Greenheck has added QR (Quick Response) codes to the labels on commercial control and air measuring dampers. When you scan the QR code with your smartphone, it will link to based on the model. Paint Finishes A wide variety of paint finishes are available including: Anodize Industrial Epoxy Baked Enamel Kynar /Hylar Epoxy Permatector Hi-Pro Polyester See color charts on for standard color offering. Factory Sleeve Option Greenheck control dampers are available with factory furnished sleeves in lengths up to 48 in. (1219mm). Sleeves are constructed out of 10 through 20 ga. (3.25 through 0.91 mm) galvanized steel. When dampers are installed in factory sleeves, the A dimension specifies the location of damper within the sleeve. Sleeve A Damper Location CL Damper Frame L Damper D* D* + 2 in. sq. Transitions Greenheck control dampers can be supplied with the appropriate transition option in applications where dampers require installation in round or oval openings. Rectangular dampers are constructed zero, 1 inch (25mm), or 2 (51mm) larger than the transition dimensions and installed in a factory sleeve. The sleeve is transitioned at each end to the appropriate round, oval, or rectangular size. Type O Type R Type C Transition options available Security Bars When security becomes an issue, Greenheck offers optional factory-installed security bars. Security bars are factory welded into a 10 ga. (3.5mm) sleeve. Open Close Indicator - OCI The OCI contains two single pole, single throw switches used to indicate damper blade position. The switches provide positive open and closed signals when used in conjunction with remote indicator lights. Switches are physically linked to a damper blade and therefore give a true representation of the damper s position. 7

8 Wide Range of Actuators Greenheck has a wide range of manual, electric, and pneumatic actuators for use with control dampers. Actuators can be installed at the factory or shipped loose with the necessary linkage and brackets required for mounting. Each damper and actuator is cycle tested in our factory before the final product is shipped, ensuring Greenheck quality and trouble free operation in the field. Manual Hand Quadrant See Figure 5 Location Internal or External Figure 5 Manual Quadrant Electric Actuator Checklist See Figures 6 & 7 Power Supply 24 VDC, 24 VAC, 120 VAC, and 240 VAC Frequency Operation Spring Return (spring will drive damper to original starting point) Power Open or Power Closed Operating Mode Two-position (damper position is open or closed) Modulating (damper position determined by modulating control signal) Floating (damper can be stopped anywhere between open and closed) Fail Direction (for spring return only) Open or Closed Location Internal or External Control Signal (for modulating only) 0-10 VDC, 2-10 VDC or 4-20 madc NEMA Enclosure 1, 3, 4, 4X, or 7 (specify one per application) Accessories Auxiliary Switches Transformers Greenheck s most commonly used electric actuator manufacturers are Honeywell, Belimo, and Siemens. Contact your Greenheck representative for other options. Figure 6 Electric External Mount Figure 7 Electric Internal Mount Pneumatic Actuator Checklist See Figure 8 Power Supply 20 psi Operation Spring Return (spring will drive damper to original starting point) Operating Mode Two-position (damper position is open or closed) Modulating (damper position determined by modulating pressure signal) Fail Direction (for spring return only) Open or Closed Location Internal or External Control Signal (for modulating only) 3-15 psi Accessories Solenoid Valves or Positioners Greenheck s most commonly used pneumatic actuator manufacturers are Siemens and Invensys. Contact your Greenheck representative for other options. Figure 8 Pneumatic 8

9 Damper Performance Testing Criteria Pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of.075 lb/ft 3 (1.2 kg/m 3 ). Actual pressure drop found in an HVAC system is a combination of many factors. This pressure drop information, along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in an HVAC system. Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of high entrance and exit losses due to the sudden changes of area in the system. 5D 6D Figure 5.3 5D Figure 5.2 Figure 5.5 D= 4 (W) (H) 3.14 D = Duct length W = Damper width H = Damper height Greenheck Fan Corporation certifies that the model AMD-23 and 33, VCD-15, 20 and VCD-40 shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to Air Performance ratings only. Greenheck Fan Corporation certifies that the model VCD-18, 23, 33, 34, 43, SEVCD-23 and 33 shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. Greenheck Fan Corporation certifies that the model ICD-44 and ICD-45 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to Air Leakage, Air Performance and Energy Efficiency ratings. 9

10 Pressure Drop Data VCD-15, 18, 20, 23 Galvanized 3V blade Economic VCD-15 and VCD-18 Blade and jamb seals VCD-18 and 23 SEVCD stainless steel 3V blade 316 stainless steel construction Blade and jamb seals 12x12 24x24 36x36 12x48 48x12 AMCA figure VCD-20V and 23V Vertical 3V blade Blade and jamb seals VCD-23V 12x12 24x24 36x36 12x48 48x12 AMCA figure VCD-33 and 34 Galvanized airfoil blade Insulated airfoil VCD-34 Blade and jamb seals SEVCD stainless steel airfoil blade 316 stainless steel construction Blade and jamb seals 12x12 24x24 36x36 12x48 48x12 AMCA figure

11 Pressure Drop Data VCD-33V Vertical galvanized airfoil blade Blade and jamb seals 12x12 24x24 36x36 12x48 48x12 AMCA figure VCD-40 Extruded aluminum airfoil blade Blades contained within the frame Blade and jamb seals 12x12 24x24 36x36 12x48 48x12 AMCA figure VCD-42 Extruded aluminum airfoil blade Galvanized frame Blade and jamb seals 12x12 24x24 36x36 12x48 48x12 AMCA figure

12 Pressure Drop Data VCD-42V Vertical extruded aluminum airfoil blade Galvanized frame Blade and jamb seals 12x12 24x24 36x36 12x48 48x12 AMCA figure VCD-43 Extruded aluminum airfoil blade Aluminum frame Blade and jamb seals 12x12 24x24 36x36 12x48 48x12 AMCA figure VCD-43V Vertical extruded aluminum airfoil blade Aluminum frame Blade and jamb seals 12x12 24x24 36x36 12x48 48x12 AMCA figure

13 Pressure Drop Data VCDR-50 and 53 Insert type round single blade Blade seals VCDR AMCA figure VCDRM-50 and 53 Insert type round multi-blade Blade seals VCDRM AMCA figure Pressure Drop Comparison Greenheck compared the AMCA licensed pressure drop data of a VCD in. wide x 12 in. high (305mm x 305mm) versus a competitor s equivalent 12 in. wide x 12 in. high (305mm x 305mm) damper. Both dampers were installed in an identical system which drew 2000 ft./min. of airflow through them. The results were dramatic! AMCA Licensed Pressure Drop Data 10.0 Pressure Drop (in. wg) in. wg 0.08 in. wg Competitor Greenheck VCD ,000 2,000 10,000 (ft./min) AMCA Figure in. x 12 in. Fabricated Airfoil Damper 13

14 Air Leakage Performance Three common code energy standards that pertain to dampers are: ASHRAE Standard Energy Standard for Buildings except Low-Rise Residential Buildings California Title 24 IECC - International Energy Conservation Code Here are the primary requirements for dampers based on each standard: ASHRAE Standard 90.1 (2010 edition) states that maximum damper leakage at 1 in. wg for a : non-motorized damper is 20 cfm/ft 2 or motorized damper is 4 cfm/ft 2. ( See Table from ASHRAE Standard 90.1) California Title 24 (2013 edition, section ) states that the dampers shall be certified in accordance with AMCA Publication 511 to have a maximum leakage of 10 cfm/ft 2 at 1 in. wg. The dampers have been tested and are able to open and close against the rated airflow and pressure of the system after 60,000 damper opening and closing cycles. IECC (2012, section C ) that outdoor air supply and exhaust opening be supplied with Class 1A motorized dampers with a maximum leakage rate of 4 cfm/ft 2 at 1 in. wg when tested in accordance with AMCA 500D. Greenheck s volume control dampers meets the requirements of ASHRAE, California Title 24 and IECC. Air Leakage Data Air leakage is based on operation between 32 and 120 F (0 and 49 C). Tested for leakage in accordance with ANSI/AMCA Standard 500-D, Figure 5.5. Tested for air performance in accordance with ANSI/AMCA Standard 500-D, Figures 5.2, 5.3 and 5.5. Torque Data is based on a torque of 5.0 in-lb/ft² (0.56 N m) applied to close and seat the damper during the test. VCD-18 Leakage Class* Maximum Damper Width 1 in. wg (0.25 kpa) 2 in. wg (0.5 kpa) 48 in. (1219mm) 1A 1 VCD-23, SEVCD-23 Leakage Class* Maximum Damper Width 1 in. wg (0.25 kpa) 4 in. wg (1 kpa) 5 in. wg (1.2 kpa) 48 in. (1219mm) 1A 1 1 VCD-43 Leakage Class* Maximum Damper Width 1 in. wg (0.25 kpa) 4 in. wg (1 kpa) 8 in. wg (2 kpa) 10 in. wg (2.5 kpa) 60 in. (1524mm) 1A Torque Data is based on a torque of 7.0 in-lb/ft² (0.79 N m) applied to close and seat the damper during the test. VCD-33, 34 SEVCD-33 Maximum Damper Width 1 in. wg (0.25 kpa) 4 in. wg (1 kpa) Leakage Class* 8 in. wg (2 kpa) 10 in. wg (2.5 kpa) 60 in. (1524mm) 1A

15 Specialty Control Dampers *Leakage Class Definitions The maximum allowable leakage is defined by AMCA as the following: Leakage Class 1A - 3 cfm/ft 1 in. wg (Class 1A is only defined at 1 in. wg). Leakage Class 1-4 cfm/ft 1 in. wg - 8 cfm/ft 4 in. wg - 11 cfm/ft 8 in. wg cfm/ft 10 in. wg Model Maximum Leakage cfm/sq. ft. 1 in. wg (.25 kpa) 4 in. wg (1 kpa) VCD-23V, 43V Class 1A Class 1 VCD-40 Class 1A Class 1 VCD-33, 42, 42V Class 1A Class 1 VCDR-53 Class 1 Class 1 VCDRM-53 Class 1 Class 1 Greenheck Fan Corporation certifies that the model VCD-18, 23, 33, 34, 43, SEVCD-23 and 33 shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. Greenheck Fan Corporation certifies that the model ICD-44 and ICD-45 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to Air Leakage, Air Performance and Energy Efficiency ratings. Specialty Control Dampers Damper/Louver in a Common Sleeve Greenheck can provide a damper and louver in a common sleeve for applications requiring single unit assembly. This assembly makes it convenient for installing in the field as one unit instead of dealing with multiple units (consult factory for more information). HEIGHT DAMPER SLEEV LOUVER Face & Bypass Dampers The face and bypass dampers are used in applications where two dampers are connected together allowing one damper to open while the other damper closes. The FBH-43 is horizontal style (side-by-side). The FBV-43 is vertical style (stacked) DAMPER LOCATION SLEEVE LENGTH FBH FBV 15

16 Specialty Control Dampers ICD - Insulated Control Damper Greenheck s ICD dampers were developed for applications where it is necessary to minimize the thermal transfer and reduce condensation. ICD series dampers meet Class 1A leakage of less than 3 cfm/sq. 1 in. wg (55 cmh/m kpa). ICD series dampers can be used in applications down to -70 F (-56 C) and up to 200 F (93 C) for: Cold food storage warehouses Buildings/warehouse Rooftop intake or exhaust AMCA Certified Energy Efficiency Performance A damper s Thermal Efficiency Ratio (E) is a comparison of the thermal performance of the tested damper with a standard reference damper. A damper that is twice as efficient as the reference damper would have an E of 100%. Cross section of thermally broken frame and blade ICD-44 ICD-45 Maximum - ft/min. (m/s) 4000 (20.3) 4000 (20.3) Maximum Pressure - in. wg (kpa) 8 (2) 8 (2) Thermal Efficiency Ratio (E) 593% 941% Temperature Range - F (C ) -70 to 200 (-56 to 93) -70 to 200 (-56 to 93) Frame Frame Type Insulated Thermally Broken Aluminum - X Aluminum X - Channel X O Quick Connect O X Reverse Flange O O Single Flange O O Blade Action Parallel O O Opposed X X Blade Type Insulated Thermally Broken X X Blade Material Extruded Aluminum Airfoil X X Blade Seal Silicone X X Jamb Seal X = Standard Stainless Steel X - Silicone O X O = Optiona Air Measuring Products Airflow measuring products are used to accurately measure and control air. Applications include meeting the minimum outdoor air requirements of ASHRAE Standard 62 or California Title 24 by providing accurate monitoring and control of outside air. Why is outside air measurement important? There are many significant benefits to monitoring outside air volumes. First, by measuring the amount of outside air coming into a building, you can be assured the building is in compliance with all applicable indoor air quality codes including ASHRAE Standard 62 and California Title 24. Meeting these minimum requirements reduces indoor airborne viruses and bacteria which can lead to Sick Building Syndrome. Studies have shown that inhabitants in buildings that are under ventilated suffer from reduced productivity levels. AMS 16

17 Specialty Control Dampers The second major advantage to monitoring outside air volumes is it eliminates costly over ventilation. In addition to increased energy costs associated with heating and cooling of outside air, over ventilation causes an increase in humidity that can result in mold development. The AMS is an accurate airflow measuring station that is furnished with a properly sized pressure transducer that outputs a 0-10 VDC signal proportional to cfm. The AMS is compatible with a field-supplied controller or a factory-supplied LON controller (sold separately). AMD series dampers were developed as an accurate low cost alternative to typical air measuring products. The AMD series comes standard with a modulating actuator and a properly sized pressure transducer that outputs a 0-10 VDC signal proportional to cfm. Many control contractors like to use their own controllers. A large label on every AMD damper shows the controls contractor everything needed to program their own controller. Field-supplied controllers can use the transducer s signal along with the flow formula (provided) to regulate a modulating actuator to the target set point. A factory-supplied controller is also available. The AMD series is also available with a factorysupplied LON controller that accepts a target flow set point as an input (either analog or digital) and outputs a 0-10 VDC signal proportional to the airflow that can be used to position a damper. Quick Selection Chart ft/min (m/s) Temperature Range F ( C) Factory Calibration Required AMD-42 featuring an extruded airfoil blade control blade AMS AMD-23 AMD-33 AMD-42 AMD-42V 2000 (10.2) -20 to 180 (-29 to 82 ) 2000 (10.2) -20 to 180 (-29 to 82 ) 2000 (10.2) -20 to 180 (-29 to 82 ) 2000 (10.2) -20 to 180 (-29 to 82 ) AMD-42V featuring an extruded airfoil vertical blade control damper 2000 (10.2) -20 to 180 (-29 to 82 ) Accuracy 5% 5% 5% 5% 5% Measures Airflow Regulates Airflow Volume Factory-Supplied Transducer Factory-Supplied Controller Airflow Straightener Blade Action Parallel Unit Depth in. (mm) 8 (203) 12 (305) 12 (305) 12 (305) 12 (305) Maximum Size 60 x 48 (1524 x 1219) 144 x 148 (3658 x 3759) AMD-23 featuring a 3V blade control damper 144 x 148 (3658 x 3759) 144 x 148 (3658 x 3759) 74 x 60 (1880 x 1524) Quick Build Program AMD-33 featuring a fabricated airfoil blade control damper 17

18 Volume Control Dampers Quick Selection Chart Blade Profile Frame Material Blade Material Frame Gauge Blade Seals Jamb Seals Bearings Axles Linkage Material Accessories Sizing (mm) Ratings 18 X = Standard O = Optional VCD-15 VCD-18 VCD-20 VCD-20V VCD-23 VCD-23V VCD-33 VCD-33V VCD-34 VCD-40 Single Blade 3V X X X X 3V-Vertical Blade X X Airfoil X X Airfoil-Vertical Blade X Airfoil-Insulated X Galvanized X X X X X X X X X 304 Stainless Steel O O O O O O O 316 Stainless Steel Aluminum Galvanized X X X X X X X X X 304 Stainless Steel O O O O O O O 316 Stainless Steel Aluminum X X X X X X X X X 12 O O O O O O O Aluminum.125 (3.2) TPE X X X X X X X Silicone O O O O O O 304 Stainless Steel X X X X X X X 316 Stainless Steel Synthetic X X X X X X X X X X Bronze O O O O O O O O O O 304 Stainless Steel O O O O O O O O O O 316 Stainless Steel Steel X X X X X X X X X X 304 Stainless Steel O O O O O O O O 316 Stainless Steel Steel X X X X X X X X X X 304 Stainless Steel O O O O O O O O 316 Stainless Steel Sleeves O O O O O O O O O Transitions O O O O O O O O O Actuators* O O O O O O O O O O Flanges** O O O O O O O O Retaining Angles O O O O O O O O O O Security Bars O O O O O O Minimum Size Maximum Single Section Size Maximum Multi- Section Size Max. ft/min. (m/s) Max. Pressure in. wg (kpa) 48x60 (1219x1524) 72x60 (1829x1524) 1500 (7.6) 2 (.5) 48x60 (1219x1524) 72x60 (1829x1524) 1500 (7.6) 2 (.5) 48x74 (1219x1880) Unlimited 3000 (15.2) 5 (1.2) * Actuators include manual, 24V, 120V, 240V, and pneumatic. ** Flanges include single, single reverse, and double flange. *** The inside of the blade is not painted on airfoil blade dampers. 74x48 (1880x1219) 148x96 (3759x2438) 3000 (15.2) 5 (1.2) 48x74 (1219x1880) Unlimited 3000 (15.2) 5 (1.2) 74x48 (1880x1219) 148x96 (3759x2438) 3000 (15.2) 5 (1.2) 60x74 (1524x1880) Unlimited 4000 (20.3) 10 (2.5) 74x60 (1880x1524) 148x96 (3759x2438) 4000 (20.3) 10 (2.5) 60x74 (1524x1880) Unlimited 4000 (20.3) 10 (2.5) X X 60x74 (1524x1880) Unlimited 6000 (30.5) 6 (1.5)

19 Volume Control Dampers Quick Selection Chart Blade Profile Frame Material Blade Material Frame Gauge Blade Seals Jamb Seals Bearings Axles Linkage Material Accessories Sizing (mm) Ratings X = Standard O = Optional VCD-42 VCD-42V VCD-43 VCD-43V SEVCD-23 SEVCD-33 VCDR-50 VCDR-53 VCDRM-50 VCDRM-53 Single Blade X X 3V X X X 3V-Vertical Blade Airfoil X X X Airfoil-Vertical Blade X X Airfoil-Insulated Galvanized X X X X X X 304 Stainless Steel O O O O 316 Stainless Steel X X Aluminum X X Galvanized X X X X 304 Stainless Steel O O O O 316 Stainless Steel X X Aluminum X X X X 20 X X 16 X X X X O O 14 O O X X 12 O O 10 O O Aluminum.125 (3.2).125 (3.2) EPDM X Vinyl TPE X X X X X X Silicone O O O O O O O 304 Stainless Steel X X X X X 316 Stainless Steel X X Synthetic X X X X Bronze O O O O X X X X 304 Stainless Steel O O O O O O O O 316 Stainless Steel X X Steel X X X X X X X X 304 Stainless Steel O O O O O O O O 316 Stainless Steel X X Steel X X X X X X 304 Stainless Steel O O O O O O 316 Stainless Steel X X Sleeves O O O O O O Transitions O O O O Actuators* O O O O O O O O O O Flanges** O O O O O O Retaining Angles O O O O Security Bars O Minimum Size Maximum Single Section Size Maximum Multi- Section Size Max. ft/min. (m/s) Max. Pressure in. wg (kpa) 60x74 (1524x1880) Unlimited 6000 (30.5) 6 (1.5) 74x60 (1880x1524) 148x96 (3759x2438) 6000 (30.5) 6 (1.5) 60x74 (1524x1880) 288 x 222 (7315 x 5639) 6000 (30.5) 10 (2.5) * Actuators include manual, 24V, 120V, 240V, and pneumatic. ** Flanges include single, single reverse, and double flange. *** The inside of the blade is not painted on airfoil blade dampers. 74x60 (1880x1524) 148x96 (3759x2438) 6000 (30.5) 6 (1.5) 48x74 (1219x1880) 60x74 (1524x1880) 4 (102) 24 (610) 4 (102) 24 (610) 10 (254) 36 (914) 10 (254) 36 (914) Unlimited Unlimited NA NA NA NA 3000 (15.2) 5 (1.2) 4000 (20.3) 10 (2.5) 3000 (15.2) 4 (1) 3000 (15.2) 4 (1) 2500 (12.7) 5 (1.2) 2500 (12.7) 5 (1.2) 19

20 Drive Arrangement Definition Each damper is given a drive arrangement code to help describe the construction of the damper. The following breaks down what each number and letter represents. 22-2FEL Number of sections wide 2 Number of sections high 3 Number of actuators or manual quadrants 4 Who supplies the actuators or manual quadrants F - Factory C - Customer Supplied (field mounted) 5 Actuator or manual quadrant mounting E - External I - Internal B - Both internal and external 6 Actuator or manual quadrant location L - Left-hand drive R - Right-hand drive B - Both right and left 7 Number of jackshafts Jackshaft Actuator or Manual Quadrant Damper Width Damper Height Enjoy Greenheck s extraordinary service, before, during and after the sale. Greenheck offers added value to our wide selection of top performing, energy-efficient products by providing several unique Greenheck service programs. Our Quick Delivery Program ensures shipment of our in-stock products within 24 hours of placing your order. Our Quick Build made-to-order products can be produced in or 15-day production cycles, depending upon their complexity. Greenheck s free Computer Aided Product Selection program (CAPS), rated by many as the best in the industry, helps you conveniently and efficiently select the right products for the challenge at hand. Greenheck has been Green for a long time! Our energy-saving products and ongoing corporate commitment to sustainability can help you qualify for LEED credits. Our 3D service allows you to download at no charge lightweight, easy-to-use AutoDesk Revit 3D drawings for many of our ventilation products. Find out more about these special Greenheck services at greenheck.com Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Prepared to Support Green Building Efforts P.O. Box 410 Schofield, WI Phone (715) greenheck.com 00.DMP.1004 R SP Copyright 2013 Greenheck Fan Corp.

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-33 Air Measuring Station with VCD-33 Control Damper Application and esign Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized

More information

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options. Application and esign Thermal ispersion Air Measuring Station with VC-23 Control amper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage

More information

Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers

Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers Life Safety Dampers Selection and Application Manual Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers May 2014 1 2 Table of Contents HOW TO USE THIS MANUAL DAMPER APPLICATION

More information

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member and stationary horizontal blades to

More information

FIRE DAMPER APPLICATION GUIDE

FIRE DAMPER APPLICATION GUIDE FIRE AND CEILING RADIATION DAMPERS FIRE DAMPER APPLICATION GUIDE Use this application guide to help determine what type of fire damper best suits the application. Below are listed the ten Metal-Fab fire

More information

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Four-Way Fan Exhaust Supply Mix Recirculate BUILDING VALUE IN AIR. October 2005 Recirculating Roof Fans Exhaust/Supply/Recirculation/Mix Model ESRMD

More information

Miami-Dade Qualified Drainable Blade Louvered Penthouse

Miami-Dade Qualified Drainable Blade Louvered Penthouse Application and Design is a gravity intake or exhaust louvered penthouse. Model incorporates high performance horizontal drainable style blades. Meets the performance requirements established by the Florida

More information

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB OVERVIEW TYPE: GGB All composite construction Rigid extruded upvc aerofoil blade section Integral blade seals for low leakage operation Individual blades driven via reinforced styrene gear wheels in maintenance

More information

security products metric sizes Redefine your comfort zone. www.titus-hvac.com

security products metric sizes Redefine your comfort zone. www.titus-hvac.com metric sizes secure lethal objects monitoring areas suicide deterrent Redefine your comfort zone. www.titus-hvac.com humid areas prevents corrosion minimum security medium security maximum security Table

More information

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment. SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 INSTALLATION INSTRUCTIONS FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS 11/2 HOUR UL555 RATED UL555S LEAKAGE RATED

More information

AIR CONDITIONING PRODUCTS COMPANY

AIR CONDITIONING PRODUCTS COMPANY Quality Products Fixed Louvers AIR CONDITIONING PRODUCTS COMPANY all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass Shutter

More information

plenum slot diffusers

plenum slot diffusers light powered Redefine your comfort zone. www.titus-hvac.com dual-function smart logic light powered energy solutions Table of Contents PLENUM SLOT IFFUSERS products Plenum Slot iffusers Products... 4

More information

MULTIZONE APPLICATION OF SOLUTION UNITS

MULTIZONE APPLICATION OF SOLUTION UNITS MULTIZONE APPLICATION OF SOLUTION UNITS APPLICATION GUIDE Supersedes: 102.20-AG12 (206) Form: 102.20-AG12 (307) GENERAL Multi-zone heating and air conditioning units offer design and application advantages

More information

INDEX. Chapter8. air master. Perforated Ceiling Diffusers

INDEX. Chapter8. air master. Perforated Ceiling Diffusers Chapter8 INDEX A. Perforated ceiling diffuser 1. Perforated ceiling diffuser with plenum box..: APCD+P...8.1. Perforated ceiling diffuser with damper....: APCD...8. Standard sizes...8. Fixing details...8.

More information

Dampers and Actuators Catalog

Dampers and Actuators Catalog Dampers and Actuators Catalog > for the latest product updates, visit us online at johnsoncontrols.com > johnsoncontrols.com > Building Efficiency > Integrated HVAC Systems > HVAC Control Products > Rectangular

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

ROOF TOP MOUNTED Air Handler Specification

ROOF TOP MOUNTED Air Handler Specification ROOF TOP MOUNTED Air Handler Specification PART 1: GENERAL (Model RT) Mechanical Specification 1.01 WORK INCLUDED A. Provide complete air handling unit(s) suitable for outdoor installation. Contractor

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

SECTION 233000 HVAC AIR DISTRIBUTION

SECTION 233000 HVAC AIR DISTRIBUTION 1320 / Talent Community Center 233000-1 HVAC AIR DISTRIBUTION SECTION 233000 HVAC AIR DISTRIBUTION PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Ductwork. 2. Ductwork accessories. 3. Fans. 4. Air

More information

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

DUCT SMOKE DETECTOR D4120

DUCT SMOKE DETECTOR D4120 Purpose/Application National and local safety standards and codes recognize the ability of air duct systems to transfer smoke, toxic gases, and flame from area to area. Sometimes smoke can be of such quantity

More information

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ TSQ--0 7-7-07 T Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T SQ Model Configuration T SQ- Heating / Cooling Border Type (Lay-In) Full Face Nominal Round Duct Size

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

Mechanical Rooftop Custom Capabilities

Mechanical Rooftop Custom Capabilities Mechanical Rooftop Custom Capabilities Mechanical Construction Capabilities Price manufactures a wide range of custom gas heat and DX cooled units to meet your new construction and retrofit needs. In addition

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

PRODUCT PROFILE FEATURES

PRODUCT PROFILE FEATURES PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER

More information

Pipe Cutting and Beveling Clamshells

Pipe Cutting and Beveling Clamshells Pipe Cutting and Beveling Clamshells Who We Are One Company, Total Support, Complete Solutions For more than a century, Hydratight has provided world-class bolted joint solutions and continues to set international

More information

UPBLAST & HOODED PROPELLER ROOF VENTILATORS

UPBLAST & HOODED PROPELLER ROOF VENTILATORS The Industrial Choice. Model D53 / B53 Model HD53 / HB53 UPBLAST & HOODED ELLER ROOF VENTILATORS Direct Drive & Belt Driven Model D53 / B53 Upblast Exhaust Fans Model HD53 / HB53 Hooded Supply & Exhaust

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

SUMMARY of PRODUCTS. HVAC Systems Control Airflow, Space, & Building Pressurization. Accurate airflow measurement for demanding applications

SUMMARY of PRODUCTS. HVAC Systems Control Airflow, Space, & Building Pressurization. Accurate airflow measurement for demanding applications SUMMARY of PRODUCTS HVAC Systems Control Airflow, Space, & Building Pressurization Accurate airflow measurement for demanding applications Airflow Measuring Stations FAN-E AIRFLOW MEASURING STATION. The

More information

Damper Selection and Sizing

Damper Selection and Sizing Damper Selection and Sizing SECTION OF ENGINEERING MANUAL OF AUTOMATIC CONTROL 77-1 Contents Introduction... 3 Definitions... 3 Damper Selection... 4 Damper Types... 4 Parallel and Opposed Blade Dampers...

More information

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

SECTION 23 81 43 HEAT PUMPS

SECTION 23 81 43 HEAT PUMPS SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:

More information

Roof Curbs, Extensions and Equipment Supports

Roof Curbs, Extensions and Equipment Supports Roof s, Extensions and Equipment Supports December 2012 Roof Page s, Header Extensions and Equipment Supports Table of Contents Model GPI Standard and Optional Construction Features... 3 Model Number Code....

More information

Pool Dehumidification Basics

Pool Dehumidification Basics Copyright 2009 Wescor. All rights reserved. Permission granted to reproduce for personal and educational use only. When energy costs were low, many pool owners considered only first cost when choosing

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

DSRQ - DSRSQ - DSRSQ-THERM

DSRQ - DSRSQ - DSRSQ-THERM DSRQ - DSRSQ - DSRSQ-THERM Specification item: Variable geometry diffuser on 597x597 mm panel developed for rooms with high ceilings where a long throw and a high induction ratio are required. Made up

More information

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

CFM @.0 SP H/M/L AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3 1/8 1468/1209/1063 60 7562/6050/4840 34/31/28 115

CFM @.0 SP H/M/L AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3 1/8 1468/1209/1063 60 7562/6050/4840 34/31/28 115 Air Circulators High Velocity Floor Fans Circulate Large Volumes of Air Product Specifications Size Spd HP HZ CFM/WATT @.0 SP AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3

More information

CURTAIN TYPE FIRE DAMPERS

CURTAIN TYPE FIRE DAMPERS URTAIN TYPE FIRE urtain Fire Damper Basics Definition of a Fire Damper: The National Fire Protection Association (NFPA) Standard 9A defines a fire damper as "a device, installed in an air distribution

More information

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators Product Bulletin Code No. LIT-1201742 Issued February 12, 2015 The M9102 and M9104 Series Actuators are directmount,

More information

CE6500 Energy Recovery Ventilator

CE6500 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge

More information

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression

More information

Ventilation Solutions Kitchens. fantech

Ventilation Solutions Kitchens. fantech Ventilation Solutions Kitchens 2 Kitchens Today s kitchens have become much more than a place for cooking and food preparation. The kitchen is the heart of the home. It s the center of activity for the

More information

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION The purpose of this guide specification is to assist the specifier in correctly specifying Mechanical System Testing

More information

DESIGN CLARIFICATION (DC)

DESIGN CLARIFICATION (DC) DESIGN CLARIFICATION (DC) Owner: Victor Valley Wastewater Reclamation Authority Date: 03/03/2015 Contractor: W M Lyles Carollo Project No.: 8299A.20 Project Name: Subregional WRPs DC No.: 001 DC Title:

More information

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm) UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery

More information

4 Installation Requirements

4 Installation Requirements 4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information

Baumann 87000 Flexsleev Sanitary Control Valve

Baumann 87000 Flexsleev Sanitary Control Valve Product Bulletin D103345X012 Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve (figures 1 and 2) is excellent for throttling high purity liquid or gaseous media commonly found

More information

Help. Help Software Tutorial. Building a load sizing project with an ME Series Humidifier

Help. Help Software Tutorial. Building a load sizing project with an ME Series Humidifier Help Help Software Tutorial Building a load sizing project with an ME Series Humidifier 502-B 18 Aug 2015 Help Tutorials provide step-by-step examples of complete load sizing projects and browser projects

More information

SECTION 23 05 12 GENERAL PROVISIONS FOR HVAC WORK

SECTION 23 05 12 GENERAL PROVISIONS FOR HVAC WORK SECTION 23 05 12 GENERAL PROVISIONS FOR HVAC WORK 1 GENERAL 1.1 GENERAL REQUIREMENTS A. This Section is coordinated with and complementary to the General Conditions and Supplementary General Conditions

More information

Operation and Installation Manual. Max Series

Operation and Installation Manual. Max Series Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat

More information

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

Installation Instructions

Installation Instructions 0.1.2....6.7..9 1 0.1.2....6.7..9 1 Installation Instructions Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions 1. Rotate the damper to its fail-safe position.

More information

Butterfly Valves PN 6/10/16 for flanged connection

Butterfly Valves PN 6/10/16 for flanged connection 4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

VariTrane Duct Designer An in depth look...

VariTrane Duct Designer An in depth look... VariTrane Duct Designer An in depth look... Introduction The VariTrane Duct Designer duct design program was written to help optimize design while obtaining a minimum pressure system. The program is based

More information

Cabinets 101: Configuring A Network Or Server Cabinet

Cabinets 101: Configuring A Network Or Server Cabinet Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What

More information

FOXAIR 60/50 ALL MODELS

FOXAIR 60/50 ALL MODELS FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,

More information

Duct Design. Presented by Dave Janquart

Duct Design. Presented by Dave Janquart Duct Design Presented by Dave Janquart Overview of Topics Duct design Duct insulation SMACNA Standards Factors Influencing Duct Design Equipment Losses Air Velocity Duct Material Duct Size & Shape Length

More information

Basic Selection & Proper Application of Overhead Air Distribution Devices

Basic Selection & Proper Application of Overhead Air Distribution Devices Basic Selection & Proper Application of Overhead Air Distribution Devices GRD Selection & Application Terms Selection Throw Sound Installation Variations affect Performance Inlet Effects Basics Return

More information

OVERALL CONVEYOR WIDTH STEEL ALUMINUM MODEL # PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT.

OVERALL CONVEYOR WIDTH STEEL ALUMINUM MODEL # PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. Pick Smarter. Pick Better. Pick UNEX. Skatewheel (SW) Skatewheel Gravity Conveyor is ideally suited to convey lightweight packages and where operations require portable or temporary conveyor lines such

More information

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Rental Services Temporary Cooling - Flexible Water Hose

Rental Services Temporary Cooling - Flexible Water Hose Engineering Bulletin Rental Services Temporary Cooling - Flexible Water Hose September 2006 CHS-PRB007-EN Warnings and Cautions Warnings and Cautions. Notice that warnings and cautions appear at appropriate

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

CT-02 CABLE TRAY SYSTEMS

CT-02 CABLE TRAY SYSTEMS CT-02 CABLE TRAY SYSTEMS SYSTEMS THAT MAKE SENSE Introduction B-Line Systems was formed in 96 and has over 30 years experience manufacturing cable tray systems in which it has grown to become the industry

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB

More information

Johnson Air-Rotation Systems

Johnson Air-Rotation Systems AR Series TM Johnson Air-Rotation Systems Solution TM D Series TM FF Series TM 80/20 PR Series TM Johnson Air-Rotation systems announces a major addition to its product line, completing its line of high

More information

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes. Accurate airflow measurement for demanding applications

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes. Accurate airflow measurement for demanding applications VOLU-probe/SS Stainless Steel Pitot Airflow Traverse Probes Accurate airflow measurement for demanding applications VOLU-probe/SS The VOLU-probe/SS Stainless Steel Pitot Airflow Traverse Probe is ideally

More information

vav retrofit terminals

vav retrofit terminals retrofit Redefine your comfort zone. www.titus-hvac.com energy solutions Table of Contents products Application Icons Key... 2 VAV Retrofit Terminals roducts... 3 external round duct series EXX, ECX and

More information

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS) August, 2009 Vertical Break Parallel (VBP) / Vertical Break Slant (VBS) Type VBPA (Aluminum) / Type VBPC (Copper) Type VBSA (Aluminum) / Type VBSC (Copper) PASCOR Air Break Switch Technology PASCOR offers

More information

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals. 600KW - 1250KW Overview Integrated design, load module, trailer, reels, cam-lock style connections, digital control High capacity, 600-1250kw Dual voltage: 208-240/416-480vAC Digital load control, 5 kw

More information

CLEAR-DIVISIONS CENTERFOLD

CLEAR-DIVISIONS CENTERFOLD CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in

More information

Answers to Your Questions from the Webinar

Answers to Your Questions from the Webinar 2008 Desert Aire and USA Swimming. Used by permission. Desert Aire & USA Swimming - Aquatics Webinar - Answers to Your Questions Answers to Your Questions from the Webinar Thank you for your interest in

More information

Tyco PremiAir Pneumatic Actuators

Tyco PremiAir Pneumatic Actuators A comprehensive range of pneumatic actuators, conforming to EN ISO 5211, providing compact, reliable and economical powered operation for all types of quarter turn valves. Features Mounting to valve either

More information

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to 1.22 1.11

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to 1.22 1.11 Knürr Miracel 19 Network and Server Rack Platform 1.12 to 1.22 1.11 19" Server Rack: Knürr Miracel Strong points 1.13 Knürr Miracel ASP ASP/Server Rack 1.16 Knürr Miracel Server Rack 1.18 Knürr Miracel

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

Exhaust Calculation Booklet

Exhaust Calculation Booklet Exhaust Calculation Booklet American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 e-mail: techsupport@amdry.com ADC Part No. 450450 Exhaust

More information

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6 - B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

Fire and Smoke Dampers: Best Practice Design Tips. An AMCA International White Paper. July 2015

Fire and Smoke Dampers: Best Practice Design Tips. An AMCA International White Paper. July 2015 July 2015 Fire and Smoke Dampers: Best Practice Design Tips An AMCA International White Paper AMCA International 30 West University Dr. Arlington Heights, IL 60004 USA www.amca.org June 2015 This white

More information

Cable Support Solutions

Cable Support Solutions Cable Support Solutions B-Line by Eaton Technology Day Japan 2013 2012 Eaton Corporation. All rights reserved. 2012 Eaton Corporation. All rights reserved. 2012 Eaton Corporation. All rights reserved.

More information

Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: sales@durasystems.com. The Passive Fire Protection Specialists

Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: sales@durasystems.com. The Passive Fire Protection Specialists Enclosures Sturdy single and double wall fire protection construction Impact resistant Fast & easy installation Pre-manufactured and modular Available in galvanized, stainless steel & other specialty metals

More information