1 Bulletin A-180b
2 Contents Product Page Wall Heaters Ceiling Heaters Baseboard Heaters Cabinet Unit Heaters Washdown Unit Heaters Hazardous Location Unit Heaters Architectural Electric Convectors
3 BRASCH Architectural Forced Air WALL Heaters Decorator Designed for Functional Beauty and Versatility Rugged Grille: Heavy dark brown 18 gauge steel grille. Richly Styled Grille: Grille is highlighted by a 14-gauge anodized extruded aluminum frame. Electric Element: Steel sheath with plate heat exchanger. Fan Delay Switch: Allows fan to continue to run for a short period after thermostat is satisfied to expel warm air from inside heater, also delays fan on start up to insure delivery of heated air. Unique Vane Axial Fan Wheel draws in large volumes of air then quietly discharges heated air downward into room. Tamper Resistant Thermostat and Disconnect Switch accessible through grille. Specifications Model Number Watts Volts Weight BWH lb. BWH lb. BWH lb. BWH lb. BWH lb. BWH / / lb. BWH / / lb. BWH / / lb. BWH / / lb. BWH lb. BWH lb. BWH lb. BWH lb. BWH lb. BWH lb. Field Installed Accessories Model Number Description Weight Box 3310 Rough-in Box Only (for advance installation) 10 lb. 3320EX33 Surface Mounting Adapter 1 lb. 3320EX16 2" Semi-recess Sleeve 1 lb. Factory Installed Accessories Suffix Description R Day Night Relay HD 16 Ga. Steel Heavy Duty Grill Architectural Quality Wall Mounted Built-in disconnect switch Built-in tamper resistant thermostat Richly styled, rugged grille Whisper-quiet sound level Fan delay 1-Year element limited warranty U.L. listed CSA listed Typical Specifications Brasch Heavy-Duty Forced Air Heaters shall be constructed of a heavy 18 gauge steel housing with an extruded aluminum frame.the rough-in dimensions are 19-5/16" high x 14-3/16" wide x 4" deep.the units shall be available in ratings from 750 to 1500 watts at 120 and 1500 to 4800 watts at 240, 208 and 277 volts.the heaters shall have a low-speed 600 RPM, 4-pole motor which drives a vane axial blower to deliver a quiet 175 CFM of down flow air. The heating element shall be of the sealed tubular type with large, parallel steel fins for quick heat transfer. Unit shall have as standard, a thermal overload cutoff for added safety, fan delay switch and a builtin tamperproof thermostat which shall be calibrated to provide a range of 55 F. to 85 F. and manual disconnect switch. Optional accessories shall include a surface mounting adapter, day-night relays. All heaters shall be listed by Underwriter's Laboratories, Inc. The heating element shall be supplied with a manufacturer s 1-year limited warranty. ELECTRIC HEATING PRODUCTS 1
4 Dimensions 2 BRASCH MANUFACTURING COMPANY, INC.
5 BRASCH CEILING Heaters Recess Surface T-Bar Versatile application Large volume of comfortably warm air is produced by a whisper-quiet heater. Ideal for residential, commercial and industrial locations where wall and floor applications are not feasible. Quiet Operation Because of the extremely quiet operation, the BCH may be used in restaurants, nursing homes, schools and lobbies. They draw in large volumes of air and discharge heated air downward into the needed areas. These heaters feature the vane axial fan that has proven to be successful in other products. Specifications Model Number Watts Volts Weight BCH lb. BCH lb. BCH lb. BCH / / lb. BCH / / lb. BCH / / lb. BCH lb. BCH lb. BCH lb. BCH lb. BCH lb. Field Installed Accessories Model Number Description Weight Box 3310 Rough-in Box Only (for advance installation) 10 lb EX33 Surface Mounting Box 1 lb. TB 3380 T-Bar Mounting Box 7 lb. Other Standard Features Include: Neutral ceiling white, rust resistant finish to blend in with most any ceiling color or decor. Grille is shallow in design to look unobtrusive. Automatic fan delay. When thermostat is satisfied, the fan continues to run momentarily until all heated air is discharged to insure efficiency. Disconnect switch. Totally enclosed steel fin sheath element for safety and long life. Mounting Applications Recess (Standard) Surface (3380 EX33 Kit) 2x2 T-Bar (TB3380 Kit) Typical Specifications Brasch Electric Forced Air Heaters shall be constructed of a heavy gauge steel housing. The rough-in dimensions are 19-5/16" high x 14-3/16" wide x 4" deep. The finish shall be baked-on enamel paint in Ceiling White color. The units shall be available in ratings from 1500 through 4800 watts. The heaters shall have a low speed 600 RPM motor which drives a vane axial blower to deliver a quiet 175 CFM of down flow air. The heating element shall be of the sealed tubular type with large, parallel steel fins for quick heat transfer. Unit shall have as standard a thermal overload cutoff for added safety. All heaters shall be listed by Underwriters' Laboratories, Incorporated. The heating element shall be supplied with a manufacturer's 1 year limited warranty. ELECTRIC HEATING PRODUCTS 3
6 Dimensions 4 BRASCH MANUFACTURING COMPANY, INC.
7 BRASCH BASEBOARD Heaters Specifications Model Number Volts Watts Heater Length B24-375A " B24-375B " B24-375C 240/ /281 24" B24-375D 277/ /281 24" B28-500A " B28-500B " B28-500C 240/ /375 28" B28-500D 277/ /375 28" B36-600A " B36-600B " B36-600C 240/ /450 36" B36-600D 277/ /450 36" B40-750A " B40-750B " B40-750C 240/ /563 40" B40-750D 277/ /563 40" B A " B B " B C 240/ /750 48" B D 277/ /750 48" B48-750D " B A " B B " B C 240/ /938 60" B D 277/ /938 60" B60-938D " B A " B B " B C 240/ / " B D 277/ / " B D " B B " B C 240/ / " B D 277/ / " B D " B B " B C 240/ / " B D 277/ / " B D " B B " B C 240/ / " B D 277/ / " B D " Stainless Steel Element Rod with Aluminum Fins All heaters are constructed of roll formed steel and painted with a powder coat textured finish for outstanding durability and attractive appearance. Brasch Baseboards are available in both ivory and white - add suffix w to model number for white. Quick connect cable clamps are located in right and left junction boxes to restrain incoming field wiring without the need for additional hardware. All baseboards are only 6" high and extend 2 1/2" from the wall making the Brasch Baseboard heater one of the most compact baseboard heaters on the market. All baseboards are constructed with a full length wireway along the back of the heater. An optional wireway cover can be ordered when specification calls for an enclosed wireway. Integral thermostats use the junction box cover plate on the baseboard heater. This eliminates the need for stocking different colors of built-in thermostats. A 6" ground lead wire is provided in both right and left junction boxes allowing for easier ground connection. The Brasch Baseboard has long-lasting stainless steel element rod with its aluminum chimney designed fins. The fins are mechanically staked to the element rod to allow excellent transfer and dissipation of heat from the heater into the room. By using a stainless steel rod, the hum associated with other models on the market is eliminated. An over-temperature thermal limit extends the entire length of the heated area to serve as a safety device in case of an air flow blockage in front of heater. All units have 20 gauge junction boxes at both ends of the heater. The front and back of the heater are constructed of 22 gauge roll formed steel. The heater can be mounted to the wall by using key hole knockouts every 4" at the back of the heater. ELECTRIC HEATING PRODUCTS 5
8 Dimensions Blank Sections Baseboard Ivory White Length Model # Model # 24" BBS024 BBS024W 28" BBS028 BBS028W 36" BBS036 BBS036W 40" BBS040 BBS040W 48" BBS048 BBS048W 60" BBS060 BBS060W 72" BBS072 BBS072W 84" BBS084 BBS084W 96" BBS096 BBS096W 120" BBS120 BBS120W Item Model Number Description Weight DS Disconnect Switch-Ivory Disconnect Switch DSW Disconnect Switch-White 1 lb. CS Ivory Corner Section Corner Sections CSW White Corner Section 1 lb. JK 1" Ivory Joiner Kit Joiner Kits JKW 1" White Joiner Kit 0.25 lb. 6" Blank Section LVRS 6" Ivory Relay Section (Relay Not Included) LVRSW 6" White Relay Section 1.5 lb. Receptacle Section BDR115 Ivory - 15amp, 120 VAC (Baseboard Mounted) BDR115W White - 15amp, 120 VAC 0.25 lb. Receptacle Section DR115 Ivory - 15amp, 120 VAC (Mtd. in 6" Blank Section) DR115W White - 15amp, 120 VAC 2 lb. Transfer Switch SR120 Ivory - 16amp, 120 VAC (Mtd. in 6" Blank Section) SR120W White - 16amp, 120 VAC 2 lb. Transfer Switch SR220 Ivory - 16amp, 240 VAC (Mtd. in 6" Blank Section) SR220W White - 16amp, 240 VAC 2 lb. Wireway Adapters (to enclose wireway when specified) Model Number Baseboard Length Adapter Length Weight WWA01 24" 20" 1 lb. WWA02 28" 24" 1.5 lb. WWA03 36" 32" 2 lb. WWA04 40" 36" 2.5 lb. WWA05 48" 44" 3 lb. WWA06 60" 56" 4 lb. WWA07 72" 68" 5 lb. WWA08 84" 80" 6 lb. WWA09 96" 92" 7 lb. WWA00 120" 116" 8 lb. Baseboard Accessories Model # TBS* TBS-TP TBD* TBD-TP * Used on all baseboard models Description SPST-In-built 22A/ V 18A/277V SPST-In-built 22A/ V 18A/277 V TAMPERPROOF DPST-In-built 22A/ V 18A/277V DPST-In-built 22A/ V 18A/277V TAMPERPROOF 6 BRASCH MANUFACTURING COMPANY, INC.
9 BRASCH Electrical CABINET UNIT Heaters The Brasch Cabinet Unit Heater (BCUH) is ideal for commercial and institutional applications such as offices, stores, schools, churches and entry ways. Standard units include a disconnect switch, built-in 24 volt thermostat and disposable air filters but the Brasch Cabinet Unit Heater can also be customized to meet your most demanding applications. All units have a beige powder coated finish over an 18 ga. steel housing that is 9 1 2" deep and 25" high and are manufactured with steel sheathed finned tubular elements with full-length thermal protection. Controls Choice of eight control options include, built-in or wall mounted thermostats (24 or 120 volt) with built-in control transformer, as needed. Independently adjustable heat settings (high / low) and fan motor speeds (1550 / 1400 rpm) are standard, except 480 volt units have a single fan speed. Power interrupt options include either a circuit breaker or disconnect switch, except only circuit breakers can be used on heaters that draw over 48 amps. Optional summer fan switch. Mounting & Flow Configurations Mounting options include surface, semi-recessed or fully-recessed; on walls or ceilings; and upright or inverted. Air flow can be configured in any combination of intake and output through the top, bottom or front. In addition, a duct collar can provide expanded application and flexibility. Air Flow Configurations A B C (May be inverted) Bottom In / Top Out (Top In / Bottom Out) Bottom In / Front Out (Top In / Front Out) Front In / Top Out (Front In / Bottom Out) Standard Models D Front In / Front Out * = Factory wired for 3 phase Field convertible to single phase
10 Custom Models
11 BRASCH WASHDOWN UNIT Heaters for Corrosion-Resistant Applications Plated Inlet Grille Scroll Stainless Steel Mounting Bracket - Easy-mount bracket for use with field-installed hanger or optional mounting brackets Totally Enclosed Motor Stainless Steel Discharge Grille Aluminum Fan Blade Element Thermostat Three-Position Switch (Heat - Fan - Off ) Pilot Light (Heater Energized) Door Interlock Disconnection Switch (Optional) Control Components (24-volt Standard) Nema 4x Non-Metallic Enclosure Rugged construction, stainless steel enclosure for use in wet* and corrosive* atmospheres (nonhazardous locations). *Refer to installation and application data for applicable environments or consult factory. The BWUH unit heaters are electric unit heaters constructed for use in areas that require washing or hosing of equipment due to dirty or dusty industrial environment in nonhazardous locations. the totallyenclosed watertight construction made with corrosion-resistant material make the BWUH Series ideal for industrial heating applications. The BWUH Series is made with all built-in controls and safety temperature controls wired in a non-metallic Nema 4x control panel with single-point power connections. ELECTRIC HEATING PRODUCTS 9
12 Standard Features: Up to 48 KW Up to 600 Volts Disconnect switch with enclosure interlock Heavy-duty 304 stainless steel shroud Nema 4x non-metallic control panel 24-volt transformer and control circuit 3-position switch (off - heat - fan) Capillary thermostat with stainless steel sensor Automatic reset thermal cutout Totally enclosed UL Listed motor Pilot light (power on indicator) Chrome-plated finned tubular element Control panel on bottom of unit for ease in installation and service Single-point power connection Meets all UL, NEC, and OSHA requirements (when installed as directed) Corrosion-resistant in high humidity and water-saturated areas (for areas where corrosion-resistance is needed in non-hazardous areas, contact factory for heater applications and optional materials). Options Teflon anodized aluminum fan blade (3-30 kw only) Remote 24-volt thermostat Stainless steel wall/ceiling mounting bracket ( kw) Cast iron painted mounting bracket available on all units for wall/ceiling or pipe mounting Hanging bracket for use with threaded rod Sample Specification The electric unit heater shall be Brasch BWUH Series rated for washdown applications and shall include built-in controls. Heaters shall be UL Listed assemblies containing all limits and controls as required by UL specifications. Controls shall be housed in a Nema 4x non-metallic control enclosure fixed to bottom of unit heater. The control enclosure will open from bottom for ease of installation and service. The control enclosure will include contactors, 24-volt transformer, fusing (NEC required) pilot light (power on), thermostat and 3-position switch (heat - off - fan). The heater scroll will be 16 gauge 304 stainless steel with 304 stainless steel outlet louvre. The inlet grille will be chrome plated. The motor shall be totally enclosed, permanently lubricated, designed to resist moisture and corrosion, and factory-wired to Nema 4x enclosure. Single point line voltage connection available for 208, 240, 277, 480, and 600 volt service. Door interlock disconnect on Nema 4x control enclosure shall be factory installed and wired. Heavy-duty heating elements factory wired and sealed for washdown application shall be plated for corrosion resistance. 10 BRASCH MANUFACTURING COMPANY, INC.
13 Washdown Unit Heater Catalog BTU Heater Standard Max. Motor Number KW HR Volts Phase Control Amps Voltage HP RPM Voltage BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / BWUH / ELECTRIC HEATING PRODUCTS 11
14 CFM RPM F Temp Air Throw Rec. Mtg. Mounting KW Outlet Outlet Rise Outlet Ft. Height/Ft. Weight Bracket A A A A A W W W W W5550 H G A E C Dimension Data B Figure 1 Figure 3 D F Figure 2 Heater Size A B C D E F G H ft ft ft ft Mounting Bracket Kits Ideal for use in buildings that have substantial walls. Arm (only) can be bolted directly to structure steel. WALL BRACKET MOUNTING ARM Simple and economical if adequate overhead structure exists. Requires 1/2" pipe, cut and threaded (not supplied). ROOF OR OVERHEAD STRUCTURE Particularly useful in buildings with insufficient strength to use other type of mounts. Requires 3 1/2" pipe (4" O.D. - not supplied). COLUMN STABILIZING COMPONENTS MOUNTING BRACKET ATTACHMENT ASSY. 3 1/2" SCHEDULE 40 (PIPE) (NOT SUPPLIED) 1/2" PIPE (NOT SUPPLIED) BASE ASSEMBLY A kw only WALL OR STRUCTURE WMK HMK PMK Optional - Wall Mounted Thermostat Raintight Industrial Thermostat The T109 series of controls is intended for use in harsh environments. They tolerate continuous spraying with water, high humidity, airborne contaminates and moderately corrosive conditions. The nickel plated sensing bulb is attached directly to the bottom of the case where it is shielded from damage or accumulators of insulating particles. The molded Noryl case is sealed at the cover with a neoprene gasket and the adjusting knob opening is closed with a lubricated 0 ring. Underwriters Laboratories has tested the T109 and found it meets the requirement for NEMA 4x enclosures. High levels of accuracy and sensitivity are provided by the T109. Switching is done by heavy duty, precision, snap action switches. Setting is accomplished by rotating the adjusting knob. The dial face is printed with large contrasting numbers and letters on a lustrous background for good visibility. Force and motion for switch actuation are provided by changes in temperature expanding or contracting the fluid contained with the sensing bulb and transmitted hydraulically and through an appropriate linkage to the switch operator. Color coding clearly identifies the function of each conductor. Switch Model Controls Action Operation TA109 Heating SPST Opens circuit on temp rise TD109 Heating, 2pole 2 SPST Opens two switches on temp. rise The T109 is available with the following characteristics: Range F Differential: 2.5 F Electrical Ratings: 120VAC 240VAC 277VAC Full Load 16.0A 12.0A 10.0A Locked Rotor 80.0A 60.0A 50.0A Non-inductive 24.0A 25.0A 22.0A Pilot Duty 125VA 125VA 125VA 12 BRASCH MANUFACTURING COMPANY, INC.
15 BRASCH HAZARDOUS LOCATION Heaters Explosion Proof Electric Heater Pressure Relief Valve Rated at 200 PSI Epoxy Coated 14 Ga. Cold Rolled Steel Cabinet Spiral Aluminum Finned Tubular Steel Heat Exchanger Core, Liquid Filled Operation 14 Ga. Steel Adjustable Louvers with Minimum Position Stops 24V Control Circuit Transformer Cast Aluminum Control Enclosure with Oversized Opening Heavy Duty Load Carrying Contactor Etched Aluminum Data Plates Riveted to Case Built-in Thermostat F (optional) Copper Sheathed Immersion Type Heating Element Liquid to air heat exchanger with low watt density heating elements in ethylene glycol solution that provides freeze protection to -45 C. Ball bearing permanently lubricated explosion proof motor. Chrome plated guard meets OSHA requirements. Heavy-duty control contactor with 24 Volt control circuit provided on all models. CAUTION Before installing and operating heaters confirm location, classification and properties of flammable vapors, liquids, gases, dusts and fibers which may be present. Each room, section or area should be considered individually. For further information consult National Electric Code and National Fire Prevention Association (ANSI) standards. All models conform to OSHA requirements when mounted at any height. For Class I, Group D, Divisions 1 & 2 and Class II, Groups E, F and G, Divisions 1 & 2 ELECTRIC HEATING PRODUCTS 13
16 BHUH Features Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain flammable gases, vapors, powdered metals or dusts. Permanently sealed, liquid to air, finned tube heat exchanger core. Ethylene Glycol to water mixture used a heat transfer fluid in the heater core, providing -45 C, (-49 F) freeze damage protection. High-performance electric motor driven fan blows air across finned tubes to effect uniform heat transfer and area heat distribution. Automatic Reset capillary type high limit provides high temperature regulation and is rated for 100,000 cycles of service. Stainless steel and aluminum pressure relief valve for overpressure condition. 14 Ga. steel cabinet epoxy paint finish contains heater core, motor and fan assembly. Narrow gap safety fan guard shields all moving parts. Adjustable louvers allow directional control of air. Copper conductor wires enclosed in rigid metal conduits carry all electrical power. (Box lugs furnished for field connections within an approved enclosure) Abbreviated descriptions of UL classes, groups and divisions. Before selecting any heater for a particular application, refer to Article 500 as well as other standards referenced in the National Electric Code. Class I: Equipment does not have surface operating temperature in excess of the ignition temperature of the specific gas or vapor. Class II: Equipment does not have surface temperature greater than the ignition temperature of the specified dust. Group D: Atmospheres such as but not limited to acetone, alcohol, gasoline, lacquer solvent vapors, natural gas, propane or other gases or vapors of equivalent hazard. Group E: Atmospheres containing combustible metal dust regardless of resistivity, or other combustible dust of similar hazard characteristics having resistivity of less than 10 OHM- Centimeter. Group F: Atmospheres containing carbon black, charcoal, coal or coke dust. Group G: Atmospheres containing combustible dust having resistivity of 10 OHM-Centimeter or greater. Division I: A location in which ignitable concentrations of flammable material exist under normal operating conditions. Division II: Locations in which flammable materials will normally be confined within closed containers and escape only in the case of accidental rupture, breakdown or during maintenance operations. Any equipment approved for Division I is automatically also approved for Division II. Built-in Hydraulic Thermostat optional on all BHUH models Stainless steel bulb and capillary 125 VA pilot duty Used on 24 volt, 120 volt or volt line voltage control 60 to 90 temp range Adjustable from front of unit with screwdriver. Hazardous Location Thermostat Wall Mounted Specifications TW161 Single Pole 22 Amps Vac 3/4 HP 125 Val 1 1/2 HP Vac 5 1/2" H x 5 1/2" W x 4 3/4" D Can be used for heating or cooling applications Installation Conditions 1. Refer to owner's manual. 2. The BHUH Series electric unit heaters have been listed by the Underwriters Laboratories for maximum surface temperatures. Use only in atmospheres having an ignition temperature higher than 165 C (T3B) for Class I operation and 165 C (T3B) for Class II. 3. Altitude restrictions - see specification table. 4. Heater must be installed in permanently mounted upright position and connected to fixed power supply. 5. Do not operate in atmospheres corrosive to steel and aluminum. 14 BRASCH MANUFACTURING COMPANY, INC.
17 Specifications BHUH Model A BHUH Model B BHUH Model C UL Capacities 3KW 10,236 BTU* 15KW 51, 180 BTU Available 5KW 17,060 10KW 34,120 BTU 20KW 68,240 BTU 7.5KW 25,590 BTU 25KW 85,300 BTU UL Listing Class I, Group D, Divisions 1 & 2 Class II, Groups E, F & G, Divisions 1 & 2 UL Temperature Code Class I: T3B 165 C (329 F) Class II: T3B 165 C (329 F) AIR CFM@70 F, (21 C) FPM Air Temp, Rise 3KW 16.3 F* 10KW 21.0 F 15KW 19.0 F 5KW 27.2 F 20KW 25.5 F 7.5KW 40.8 F 25KW 32.3 F Horizontal Throw 24 ft. 40 ft. 43 ft. Max. Mtg. Height from floor 8 ft. 10 ft. 13 ft. Max. Operational Altitude 7.5KW 5500 ft. 25KW 5500 ft. 3* & 5KW 8000 ft. 10KW 8000 ft. 20KW 7000 ft. 15KW 8000 ft. Ambient Temp. Limits Min. -45 C, (-49 F) Max. 40 C, (104 F) MTR/BLADE RPM Propeller Fan 3 Wing, Alum. 12" Dia. 16" Dia. 20" Dia. Motor Motor Voltage/Phase same as element. PSC, Explosion-Proof, Permanently Lubricated, Ball Bearing 1/4 HP 1/4 HP 1/2 HP HEAT Heat Exchanger Heavy wall, liquid filled with immersion elements. EXCHANGER Core Material Steel with aluminum fins. Heat Transfer Fluid Ethylene-glycol solution, protected to -45 C (-49 F) Heating Elements Three, low watt density, immersion type copper sheathed. PROTECTION Thermal Cut-Out Snap action capillary type rated 100,000 cycles pilot duty. Relief Valve Stainless steel and aluminum construction, 200 PSI CABINET Cabinet 14 gauge cold rolled steel, epoxy coated, individually adjustable louvers. Fan Guard Wire, less than 1/4" spacing, plated, split design for easy removal Fasteners Zinc plated. Conduit Material 3/4 rigid metal Control Box Cast aluminum with over-sized opening. (2) 1" NPS with conduits stops for field wiring. Hanger Connections 5/8" NC tap, 2 holes. CONTROLS Contactors Heavy duty, break all ungrounded conductors rated 100,000 full load. Built-in and pre-wired. Control Transformer Built-in and pre-wired - 24 volt secondary (standard) 120 volt (optional) Control Circuits 24 volt standard on all models 120 volt optional on all models (not available on 600V models) Line voltage on 208 and 240 volt models only Remote wall mounted Explosion proof F operating range 22A Thermostat Model TW VAC - 125VAC; 1 1/ VAC Built-in "T" Option 125 VA pilot duty Sensing Bulb and Capillary made from 300 Series Stainless Steel ASW Tube Heater Net Weight 132 lbs. 3 & 5KW 158 lbs. 10KW 190 lbs. 15 & 20KW Shipping Weight 167 lbs. 7.5KW 225 lbs. 25KW ELECTRIC HEATING PRODUCTS 15
18 Mounting Bracket Kits Column Stabilizing Components Mounting Arm Assy. Attachment Assy. 1/2" Pipe (Not Supplied) Roof or Overhead Structure 3 1/2" Schedule 40 (Pipe), (Not Supplied) BHHM Hanging Mounting Kit Simple and economical if adequate overhead structure exists. Requires 1/2" pipe, cut and threaded (no supplied). PIPE KITS BHPM 75 BHPM 10 BHPM 25 HANGING KITS BHHM 3 to 7.5KW Models 10KW Models 15 to 25KW Models All Models Base Assembly Attachment Assembly Wall Bracket Mounting Arm WALL MOUNTING KITS BHWM 75 3 to 7.5KW Models BHWM 10 10KW Models BHWM to 25KW Models BHPM Pipe Mounting Kit Particularly useful in buildings with insufficient strength to use other type of mounts. Requires 3 1/2" pipe (4" O.D. - not supplied). Wall or Structure BHWM Wall Mounting Kit Ideal for use in buildings that have substantial walls. Arm only can also be bolted directly to structural steel. Sample Specifications Contactors shall supply and install Brasch type BHUH explosion-proof suspended fan-forced unit heaters of the capacity and voltage listed on the plans. Heaters shall be UL listed for Class I, Group D, Divisions 1 & 2 and Class II, Groups E, F and G, Divisions 1 & 2, UL temperature code shall be T3B (165 C) for Class 1, and T3B (165 C) for Class II, indicating maximum operating surface temperatures. Physical Dimensions Inches C Model A B 3Ø 1Ø D E F G BHUH-A 17 3/4 22 3/8 19 3/4 20 5/8 16 1/4 10 1/ BHUH-B 20 3/4 26 3/8 20 3/4 21 5/8 20 1/4 11 1/ BHUH-C 24 3/4 30 3/8 22 1/2 24 1/4 12 1/ /2 Heat exchangers shall be heavy walled, liquid filled, with three, low watt density, immersion type copper sheathed elements hermetically sealed into the core along with the high limit thermal cut-out. Heat transfer fluid shall be ethylene-glycol solution, protected to -45 C (-49 F). Motors shall be PSC, explosion-proof, permanently lubricated, ball bearing type, 1725 rpm. Contactors shall be built-in and pre-wired into an explosion-proof enclosure. Contactors shall be heavy duty and break all ungrounded conductors and be rated for 100,000 cycles at full load. Control transformers shall be built-in and pre-wired. Control circuits shall be 24 volt. Cabinet shall be 14 gauge cold rolled steel, epoxy coated plated fan guard shall have less than 1/4 inch spacing to conform with OSHA requirements. All fasteners shall be zinc plated. Heater conduits shall be cadmium plated seamless steel or aluminum. Mounting Kits Brasch offers three mounting kits available for the Series: the BHPM Pipe Mounting Kit; the BHHM Hanging Mounting Kit; and the BHWM Wall Mounting Kit. Each of these is illustrated and described in this brochure.to order, specify the type of kit with the heater model desired. Consult our Sales Department for details. 16 BRASCH MANUFACTURING COMPANY, INC.
19 Performance Data Heater Line Air Temp Min Cir Max Fuse Min. Wire Size Model Volts Phase KW Amps Amps BTU/HR Rise Deg F Ampacity Amps AWG?* BHUH 7.5 BHUH BHUH BHUH BHUH BHUH BHUH BHUH BHUH BHUH BHUH BHUH BHUH BHUH BHUH BHUH BHUH BHUH BHUH BHUH 10 BHUH BHUH BHUH BHUH BHUH BHUH 25 BHUH BHUH BHUH BHUH BHUH BHUH BHUH BHUH *Supply conductors must be suitable for 90 C Controls Standard unit includes 24 volt transformer and contactors 120 volt option delete 24 suffix on model # add 120 to model # Thermostats Add suffix "T" to model # for built-in thermostat Remote thermostat see wall thermostat specifications on page volt models available with 24 volt controls only ELECTRIC HEATING PRODUCTS 17
20 Shown: 3 Phase Heater with 120 Volt Control Fusing Not Required on 24V Class II Transformer 18 BRASCH MANUFACTURING COMPANY, INC.
21 BRASCH ARCHITECTURAL ELECTRIC CONVECTORS Architectural Convectors are custom built with unsurpassed craftsmanship. Standard length and custom fitted draft barrier, sill height and pedestal heaters meet the most demanding architectural specifications. Low initial cost and negligible maintenance make them suitable for all projects stressing energy and cost optimization. Application Brasch Architectural Convectors are ideal for perimeter heating of schools, lobby areas, public buildings, nursing homes and other commercial applications providing individual room control and warm air draft protection for wall and window exposures. Heating capabilities to 750 watts per foot in a wide variety of cabinet styles provide continuous clean horizontal lines to complement any building project. Enclosures are available in standard and special painted colors and in clear and color anodized finishes. Construction Features Snap-fit construction saves installation time, eliminates unsightly screws. Pencil-proof louvers have 1/4 inch spacings. Heavy gauge extruded aluminum grilles with 15 degree angled louvers direct heated air away from wall for cleaner operation. Enclosures are fabricated of heavy gauge materials to assure compliance with architectural requirements to withstand years of rough usage. All enclosures can be finished to match window mullions, wall surfaces and interior decor. Multiple heaters factory wired on the same backplate are available up to maximum front enclosure lengths (see Table 1). Front cover enclosures are available in continuous lengths up to maximums (see Table 1) to eliminate unnecessary splices (special order). Aluminum only. Full length thermal cutout with automatic reset prevents overheating when airflow is blocked. Heating elements mounted on free floating nylon bushings for quiet operation. Aluminum sheath element has mechanically bonded fins for cooler operating temperatures. Built-in 1/2 inch EMT raceway allows field wiring from either end. (3/4 inch EMT also available). Control section can accommodate optional controls as required. Junction boxes in heaters (except DBTS) will accept most controls (see page 23). Optional controls include thermostat, disconnect (with or without 20 amp fuse and fuse block), power relay, transformer relay and PE switch. Snap-fit Construction 1/4" Pencil-proof Louvers Aluminum Front Cover Accessories (see page 23) include end caps, wall trim splice plates, inside and outside corners, mullion fronts, inside fillers, blank sections, control sections, 1/4 inch wire mesh under grille, pedestals and duplex receptacles. Disconnect switch and relay, separately or in combination with thermostat, allow for right hand wire entry. Integral thermostat allows wire entry at either end. Finishes The standard finish on all heaters is ASI Bronze paint. Other standardized paint colors which are available are Eggshell White, Beige, Gray, and Black. Anodized finishes can be provided on aluminum enclosure heaters. Those available are 204R1 Clear, 313R1 Bronze and Black. Actual samples of any of the foregoing finishes can be provided upon request. Additionally, special painted colors can be provided to match submitted color samples. Heater backs (except RDBT- PD) are not finished unless specified. Back Cover High Efficiency Bonded Aluminum Fins Assure Cool Surface Temperatures Junction Box Features Built-in Thermostat And Disconnect if Required Full Length Thermal Overload Protection ELECTRIC HEATING PRODUCTS 19
22 Standard Profile Draft Barriers DBF & DBT These heaters have a 6" x 3 1/2" profile with a snap-fit extruded aluminum enclosure and a 12 ga. aluminum backplate. The DBF is available with up to 250 watts per foot of heating and the DBT with up to 300 watts per foot of heating. DBF is designed for floor mounting with front inlet and top outlet. DBT is designed for wall mounting with bottom inlet and top outlet but pedestals can be supplied for floor mounting. Low Profile Draft Barriers DBTS & CB The DBTS heater has a 4" x 2 5/8" profile and the CB heater has a 4 1/2" x 2 5/8" profile. Both have a snap-fit extruded aluminum enclosure and a 14 ga. aluminum backplate.the DBTS heater is available with up to 300 watts per foot of heating.the CB heater is available with up to 250 watts per foot of heating. Both are designed for wall mounting with bottom inlet and top outlet but pedestals can be supplied for floor mounting. Table 1: Model Comparisons Dual Element Draft Barriers DBCF & DBCT These heaters have a 7" x 5" profile with a snap-fit extruded aluminum enclosure and a 10 ga. aluminum backplate. The DBCF is available with up to 650 watts per foot of heating and the DBCT with up to 750 watts per foot of heating. DBCF is designed for floor mounting with front inlet and top outlet. DBCT is designed for wall mounting with bottom inlet and top outlet but pedestals can be supplied for floor mounting. Sill Height Draft Barriers ASHDB The ASHDB has a standard 5 1/2" depth and heights are available from 8" to 20" in 1/16" increments specify height required. The front cover is 16 ga. steel and the backplate is 18 ga. steel. The grille is extruded aluminum. The ASHDB is available with up to 500 watts per foot of heating. The heater is designed for wall mounting with bottom inlet and top outlet. Pedestals can be supplied for floor mounting of 8" height only. Rounded Pedestal Draft Barriers RDBT-PD The RDBT-PD heater has a rounded 6" x 7" profile with a flat bottom and a flat top and has an extruded aluminum enclosure.the heater is supported on 1 3/4" - 2 1/4" adjustable pedestals.the RDBT-PD is available with up to 300 watts per foot of heating.the heater is designed for floor mounting with bottom inlet and top outlet. Standard Elements The following standard elements are available in even foot lengths at the watts per foot heat outputs shown for single phase voltages: DBCF, DBCT and ASHDB can be furnished with any combination of two elements. Special elements at different heat outputs and/or lengths are available. Enclosure Maximum Front Finishes Dimension Heat Enclosure/ Model Type (H x D) Airflow Watts/Ft Max Length Grilles Mounting Standard Optional DBF Standard 6" x 3 1/2" Front Inlet " Extruded Extruded Floor Painted Color or Clear Anodized Top Outlet Aluminum/15 Ft. Aluminum Bronze Std. and Spcl. Painted Colors DBT Standard 6" x 3 1/2" Bottom Inlet " Extruded Extruded Wall Painted Color or Clear Anodized Top Outlet Aluminum/15 Ft. Aluminum Bronze Std. and Spcl. Painted Colors DBTS Low Profile 4" x 2 5/8" Bottom Inlet " Extruded Extruded Wall Painted Color or Clear Anodized Top Outlet Aluminum/15 Ft. Aluminum Bronze Std. and Spcl. Painted Colors CB Low Profile 4 1/2" x 2 5/8" Bottom Inlet " Extruded Extruded Wall Painted Color or Clear Anodized Top Outlet Aluminum/15 Ft. Aluminum Bronze Std. and Spcl. Painted Colors DBCF Dual Element 7" x 5" Front Outlet " Extruded Extruded Floor Painted Color or Clear Anodized Top Outlet Aluminum/12 Ft. Aluminum Bronze Std. and Spcl. Painted Colors DBCT Dual Element 7" x 5" Bottom Outlet " Extruded Extruded Wall Painted Color or Clear Anodized Top Outlet Aluminum/12Ft. Aluminum Bronze Std. and Spcl. Painted Colors ASHDB Sill Height 8" - 20" Bottom Inlet ga. Steel/ Extruded Wall Painted Std. and Spcl. Painted Colors X 5 1/2" Top Outlet 10 Ft. Aluminum Bronze RDBT-PD Rounded 6" x 7" Bottom Inlet " Extruded Extruded Floor Painted Color or Clear Anodized Top Outlet Aluminum/12 Ft. Aluminum Bronze Std. and Spcl. Painted Colors 20 BRASCH MANUFACTURING COMPANY, INC.
23 Accessories IC Inside Corner OC Outside Corner EC End Cap left or right (N/A RDBT-PD) IEC Inside Fitting End Cap left or right (N/A DBTS, CB, DBCF, AHSDB) WT Wall Trim SP Splice Plate, 1 1/2" - 6" (N/A RDBT-PD) MF Mullion Front to 1 foot (DBF, DBT, CB only) IF Inside Filler to 1 foot (DBF, DBT, DBCT only) BS Blank Section specify length (1'-0" to 10'-0") ASB Conduit 3/4" Raceway (1/2" Standard) ASB Mesh 1/4" wire mesh under grille ASB DR Duplex Convenience Receptacles ASB PD Pedestals specify 2" or 3" (3" over 300W/Ft) Controls CS Control Section 6" or 12" ITS Single Pole Thermostat 20 amps ITD Double Pole Thermostat 20 amps IDS Double Pole Disconnect 20 amps IDSF Double Pole Disconnect w/20 amp fuse and fuse block PR Power Relay 18 amps TR Transformer Relay PE Pressure Electric Switch DBTS requires a CS with any controls. A six inch CS will accept 1 or 2 controls, a twelve inch CS will accept 3 controls. CB will accept only a thermostat, disconnect or power relay in the junction box. More or other controls require a CS. All other heaters will accept any two of the following controls to be installed in the junction box disconnect and thermostat, disconnect and power relay or disconnect and PE switch. Increase the length of the heater enclosure by 6" or 12" when using a control section. Integral thermostats are mounted on the left side unless otherwise specified; integral disconnects are mounted on the right side unless otherwise specified; integral relays are mounted on the left side unless otherwise specified. Heaters are wired for either right or left hand entry where there are no controls. Otherwise, entry is in the junction box containing the controls. How to Order Example: Model Number DBF ASI Bronze-ITS Model Length (in feet) Watts per foot Voltage Finish Color Built-in Controls When Ordering, specify: Model Number Length (in feet) Watts Per Foot Voltage Finish Color Built-in Controls ELECTRIC HEATING PRODUCTS 21
24 Sample Specification Electric convectors shall be architectural series by Brasch Manufacturing Co., Inc. as scheduled: Series Description Height By Depth DBF Draft Barrier (front inlet) 6" x 3 1/2" DBT Draft barrier (bottom inlet) 6" x 3 1/2" DBTS Draft barrier (bottom inlet) 4" x 2 5/8" CB Draft barrier (bottom inlet) 4 1/2" x 2 5/8" DBCF Draft barrier (front inlet) 7" x 5" DBCT Draft barrier (bottom inlet) 7" x 5" ASHDB Sill Height (bottom inlet) 8" - 20" x 5 1/2" RDBT-PD Rounded Pedestal (bottom inlet) 6" x 7" Draft barrier shall be fabricated of aluminum extrusions with 1/4" pencilproof louvers at a 15" angle for improved convection and cleaner operation. Cabinets to have clean square corners, suitable for front or bottom intake and heating at watts per foot as scheduled. Sill height convectors shall be fabricated of 16 gauge furniture steel with 14 gauge extruded aluminum, pencil-proof louvers installed at a 15 angle for improved convection and cleaner operation. Enclosure covers, louvers and end caps will snap-fit together without screws or fasteners for easy maintenance. Wallmounted units shall have pre-punched slots for quick installation. Pedestal and mullion-to-mullion units to have solid finished backs without slots. Standard backed acrylic bronze or optional painted or anodized finish will be provided in architectural colors as scheduled. Provide full length linear thermal cutout with automatic reset on all units to prevent overheating from blocked airflow. Provide built-in EMT raceway with factory wiring and 3/4" knockouts on side and rear of junction boxes at each end. Heater to accept field wiring at either end when optional controls are not included. Blank sections shall be fully enclosed for branch circuit wiring. Heating elements shall be aluminum sheath with mechanically bonded fins to maximize heat transfer and limit fin temperatures to 330 F. Elements shall be centered in freefloating nylon bushings for quiet operation. Per schedule, controls include single or double pole thermostats, disconnect switches, and relays. Thermostats shall be adjustable (tamperproof ) through discharge louver. Separate control sections shall include factory mounted PE switches, mercury contactors, circuit breakers and control transformers (as scheduled). Accessories shall include end caps, wall trim, splice plates, inside and outside corners, and blank sections of matching material for visual continuity. All heaters and controls shall be listed by Underwriters Laboratories, Inc. and warranted for one year from date of sale. 22 BRASCH MANUFACTURING COMPANY, INC.
25 Limited Warranty All Brasch Manufacturing Company, Inc. products covered in this bulletin are warranted against defects in workmanship and materials for one year from date of purchase. This warranty does not apply to damage from accident, misuse or alteration; nor where the connected voltage is more than 5% above product nameplate voltage; nor to equipment improperly installed or wired or maintained in violation of installation instructions. This warranty is valid only in the fifty states of the United States. No other written or oral warranty applies. No employee, agent, dealer or other person is authorized to extend warranty on behalf of Brasch Manufacturing Company. The customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs. Inoperative units should be returned to Brasch, attention of Service Manager for repair or replacement at our option. Product will be returned freight prepaid. Repair or replacement is the exclusive remedy available from Brasch who is not liable for damages of any kind, including incidental and consequential damage.
26 2310 Millpark Drive M a r y l a n d H e i g h t s, MO Fax sales@braschmfg.com Brasch Manufacturing Company, Inc.
ELEC ELE TR CTRIC P IC PRODUCTS RODUCT
ELECTRIC PRODUCTS VCEP-1 ELECTRIC PRODUCTS MODEL SB STANDARD SBF SBT SB FEATURES SBST - Bottom intake, slope discharge SBT - Bottom intake, top discharge SBF - Front intake, top discharge Two piece all
More informationExplosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
More informationUHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual
UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to
More informationAll work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
More informationGas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
More informationCommercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
More informationPRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
More informationPump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationMAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
More informationScrew Plug Immersion Heaters
Immersion Heaters Overview Immersion Heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. Immersion Heaters
More informationALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation
More informationELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to
More informationRoof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
More informationMODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS
1.5, 2, 2.5, 3, 3.5, 4, 5 & 6 Ton Industrial Grade Wall Mounted Air Conditioners & Heat Pumps Unit Application Bebco Model IX-WAC/HP Industrial Grade Air Conditioners & Heat Pumps are designed as a total
More informationPump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationLow Profile Unit Cooler
Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost
More informationUtility Distribution Systems
Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date
More informationM7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
More informationLight Duty Commercial Electric Water Heater
Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and
More informationTECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES
TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change
More information12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations
12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling
More informationOne Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty
One Year Warranty ELECTRIC Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches Fused Ceramic Shield tank lining is corrosion-resistant for years of dependability. Adjustable
More informationChromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION
Chromalox Installation, Operation RENEWAL PARTS IDENTIFICATION Portable Industrial Unit Blower Air Type DRA and DIVISION SALES REFERENCE DATE SECTION (Supersedes P-) PF-) NOVEMBER, 00 DRA PF- -0-00 Specifications
More informationSECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
More informationPARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM
PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM RELIANCE Has Everything Your Customers Need to Do the Job Right! Reliance Water Heater Company was founded in 1981 to provide a water heater
More informationSECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
More informationSECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
More information300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
More informationTABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
More informationINSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI Page 2 / 16 CONTENTS 1 GENERAL... 3 2 SAFETY... 3 2.1 Safety instructions... 3 2.2 Correct use... 3 3 DESCRIPTION
More informationTWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER
TWIN EAGLES, INC. Defining the Art of Outdoor Cooking TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER OWNER S MANUAL MODEL TEEH-1512 TEEH-2524 TEEH-3524 NEED ASSISTANCE? PLEASE CALL: (562) 802-3488 This
More informationPAINT BOOTH LIGHTING
PAINT BOOTH LIGHTING PAINT BOOTH LIGHTING Lighting is comprised of many components that need to be considered when selecting the appropriate fixtures and lamps to accomplish a specific task. Selecting
More informationINSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
More informationINSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER
INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS IMPORTANT INFORMATION Warnings 2 Installation Instructions 3 Wiring Instructions 3 Outdoor
More informationREFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:
7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca
More informationINSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER The instructions that follow are to assist you in completing the information required when making a fan or blower selection. If you need additional
More informationFan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.
COMPACT UNIT FOR CEILING OR WALL MOUNT Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain. MJ-40 400 600 7 13 5/8 8 125 5 1/4" 0.65 0.35
More informationRecirculating Roof Fans Models ESRMD, ESRMDF and ERD
Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Four-Way Fan Exhaust Supply Mix Recirculate BUILDING VALUE IN AIR. October 2005 Recirculating Roof Fans Exhaust/Supply/Recirculation/Mix Model ESRMD
More informationETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
More informationCONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13
CONTROL PANEL INSTALLATION INSTRUCTIONS Single Phase Simplex Page 2-7 3-Phase Simplex Page 8-13 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions
More informationHorizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in
More informationSECTION 15732 AIR CONDITIONING UNIT
SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx
More informationHL Series - Commercial Heaters Tankless Water Heating Solutions
HL Series - Commercial Heaters 5-18 kw (17,000-61,400 BTUs) Low flow activation options at.15 and.25 GPM (0.6 and 0.9 L-Min) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage
More informationFire Alarm System Accessories
Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer
More informationOwner s Manual EFX. Explosion-Proof Exhaust Fan. This manual covers installations, maintenance, repair and replacement parts. WARNING!
Heaters for the Harshest Environments Owner s Manual ISO 9001 EFX Explosion-Proof Exhaust Fan This manual covers installations, maintenance, repair and replacement parts. WARNING! READ ALL IMPORTANT NOTICES
More informationFOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationCFM @.0 SP H/M/L AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3 1/8 1468/1209/1063 60 7562/6050/4840 34/31/28 115
Air Circulators High Velocity Floor Fans Circulate Large Volumes of Air Product Specifications Size Spd HP HZ CFM/WATT @.0 SP AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3
More informationOWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
More informationT15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200
INSTRUCTION MANUAL FOR: T15 AIR CONDITIONER McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleanthermal.com INSTRUCTION MANUAL TABLE OF CONTENTS
More informationCabinets 101: Configuring A Network Or Server Cabinet
Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What
More information12V Portable Diaphragm Compressor Operating and Maintenance Instructions
12V Portable Diaphragm Compressor Operating and Maintenance Instructions (Part No. DC2) Part No. Serial Number Date Purchased Table of Contents Page Safety Messages...2 Guidelines for Product Use...2 Operation
More informationElectric Unit Heaters
Electric Unit Heaters Model UHAA Model UHWA Model UHRA Model UHXA Model UHEC Model UHCA August 2005 Introduction Introduction Electric unit heaters have been a traditional means of heating hard-to-warm
More informationVertical Break Parallel (VBP) / Vertical Break Slant (VBS)
August, 2009 Vertical Break Parallel (VBP) / Vertical Break Slant (VBS) Type VBPA (Aluminum) / Type VBPC (Copper) Type VBSA (Aluminum) / Type VBSC (Copper) PASCOR Air Break Switch Technology PASCOR offers
More informationLow Voltage Transformers Sealed, General Purpose, Dry Type
Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................
More informationHeating Cable. Construction
Mineral Insulated High Temperature A C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to F (593 C) Maximum Exposure Temperature 4 F (76 C) (Power Off) Corrosion Resistant
More informationINSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check
More informationA. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.
SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel
More informationAdvantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
More informationInstallation and Operating Instruction Manual
Electric Mini Tank Water Heaters CMT-1.3 CMT-2.5 CMT-4.0 CMT-ST70 Tempering valve Optionally available Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 3 General
More informationPROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167
PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION
More informationOPERATING MANUAL CONTRACTOR STYLE AXIAL FANS
Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN
More information"EC" Series Electric Humidifier
EC-1 Standard Water "EC" Series Electric The Electric from PURE Co. is loaded with features and options. All you need is tap water, electricity, and a sanitary drain. The humidifier does the rest. These
More informationI nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
More informationInstallation & Maintenance Instructions
(400mm) 15-3/4" (35mm) 1-3/8" (95mm) 3-3/4" K Series (Model A) Fan Forced Wall Heaters (485mm) 19-1/8" (463mm) 18-1/4" FILE #E21609 Installation & Maintenance Instructions Dear Owner, Congratulations Thank
More informationMini Tank. Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0. Installation and Operating Instruction Manual
Mini Tank Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0 Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 3 General Information 3/6 Technical
More informationLOBOY 16 AIR CONDITIONERS
INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com
More informationGenerator DoCKInG StatIonS
Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed
More informationData Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?
Data Bulletin April 2001 Raleigh, NC, USA Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW Variable frequency drives are available from manufacturers as enclosed engineered
More informationElectric Water Heater
Electric Water Heater Operation and Installation Manual (LIMITED WARRANTY AND TANK REPLACEMENT POLICY) The following information should be noted at time of installation and retained for future reference.
More informationIMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
More informationINFRARED RADIANT HEATERS. air heaters
INFRARED RADIANT HEATERS OVERVIEW Economic, efficient, and clean, WATTCO infrared radiant heaters are designed for comfort heating applications that require radiant heat in indoor, outdoor, and exposed
More informationE2 Series Electric Furnaces
E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...
More informationDTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
More informationSeaward Products OWNER S MANUAL WATER HEATERS. Serial Number:
Seaward Products WATER HEATERS OWNER S MANUAL Serial Number: IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, basic safety precautions to reduce the risk of fire, electrical shock,
More informationSECTION 23 81 43 HEAT PUMPS
SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:
More informationHOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS
HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY
More informationAIR CONDITIONING PRODUCTS COMPANY
Quality Products Fixed Louvers AIR CONDITIONING PRODUCTS COMPANY all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass Shutter
More informationAlpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery
Alpha System ADAPTABLE LABORATORY FURNITURE KEWAUNEE encouraging new discovery Alpha 6 partition modules with Kemresin worktops. Minneapolis, Minnesota Alpha 6 partition modules with Alpha overhead service
More informationFor Models #6-5001, #6-7501, #10-7501 & #10-12K1
EmerGen Switch Manual Transfer Switch Manufactured by CONNECTICUT ELECTRIC SWITCH MFG. CO. 1-800-730-2557 OWNER S MANUAL & INSTALLATION INSTRUCTIONS For Models #6-5001, #6-7501, #10-7501 & #10-12K1 PLEASE
More informationMODEL BRT GAS-FIRED TUBULAR UNIT HEATERS
CATALOG NO.: BRTPC-3 GAS-FIRED UNIT HEATERS MODEL BRT GAS-FIRED TUBULAR UNIT HEATERS CATALOG INDEX WARRANTY INFORMATION RETURN GOODS...2 BRT-30/120...3, 4, 5 OPTIONAL PARTS...6 CONVERSION KITS...7 TERMS...8
More informationJOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.
Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid
More informationElectrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
More informationModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60
ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac II air conditioner is a vertical, wall mounted, cost effective air conditioner
More informationBERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
More informationUSER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
More informationReplacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
More informationCommercial Electric Water Heater
MODEL SE Commercial Electric Water Heater 6-120 Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages Features Heavy Duty Construction Hydrastone cement lining
More informationElectric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075
Part No. 89047 Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075 Cincinnati, OH 45241-4807 USA ELECTRIC FRYER SAFETY PRECAUTIONS Installation
More informationElectric Mini Tank Water Heaters WM-2.5 & WM-4.0
Electric Mini Tank Water Heaters WM-2.5 & WM-4.0 Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 2 Technical Data 3-4 General Information 5 Technical Description
More informationMETER REQUIREMENTS GENERAL REQUIREMENTS SECTION D
12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section
More information2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property
2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical
More informationScraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
More information2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
More informationThermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.
Thermwire Freeze Protection Heating Cable Selection Guide Pipe Freeze Protection Heating Cable Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord & Plug Thermwire-Comp Refrigeration
More informationF9MXE. Product Specifications
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Select models earn the ENERGY STAR (See below, indicated with check mark.) Xtra SEER ECM blower motor Supports
More information