1 Normally Closed or Normally Open ot Water and Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT 2/2 Features ot water service to 210 psi 210 F; sevice to 125 psi 353 F Specify these valves for the high-temperature applications found in laundries, molding, steam atomization, sterilizers, autoclaves, and many others Series 8263: direct acting miniature valves Series 8267: direct acting straight-through, self-cleaning design Series 8210/8220: pilot operated diaphragm valves Lead-free versions available on 8210 ot Water valves for Safe Drinking Water Act compliance Series 8220: pilot operated diaphragm and piston valves; floating PTFE diaphragms or stainless steel pistons with EPDM or PTFE discs, available in both AC & DC voltages Series 8221: slow-closing, anti-water hammer design Series 8222: pilot operated diaphragm and piston valves. Y-body floating piston design Construction Valve Parts in Contact with Fluids Common Parts Body Brass Stainless Steel Core Tube 305 Stainless Steel Core and Plugnut 30F Stainless Steel Springs 302 Stainless Steel Shading Coil Copper Silver 8210W Series Seals, Discs, and Diaphragms EPDM 8263 Series Seals EPDM or PTFE Disc EPDM or PTFE 8220/8221 Series Piston/Diaphragm Stainless Steel/PTFE Discs EPDM or PTFE Seals EPDM, PTFE or TFE/P 8222 Series Seals, Discs, and Diaphragms TFE/P, EPDM and/or PTFE Piston Brass or PTFE 8267 Series Seals FKM, PTFE Disc Stainless Steel Seat Glass-Filled PTFE Electrical Standard Coil and Class of Insulation F Const. Ref. 1,2,36,38,39, 0,1,2 Watt Rating and Power Consumption Spare Coil Part Number AC General Purpose Explosionproof DC Watts Watts VA olding VA Inrush AC DC AC DC F, 8, 33, F F 5,7,10,1,15, 28,30,32,3, ,52,53 F 16,17, , ,12,1,51, 52, F 21-27, , ,11, ^ % ) Solenoid Enclosures NC NO Standard: Redat II - Watertight, Types 1, 2, 3, 3S,, and X; Red-at - Type 1. Optional: Redat II - Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9; Redat - Explosionproof and Raintight, Types 3, 7, and 9. (To order, add prefix EF to catalog number.) See Optional Features Section for other available options. Nominal Ambient Temp. Ranges Redat II AC: 32 F to 125 F (0 C to 52 C) For 8263 /ot Water Series Redat II AC: 32 F to 131 F (0 C to 55 C) For 8210 ot Water Series Redat II DC: 32 F to 10 F (0 C to 0 C) For 8220 /ot Water Series Redat II DC: 32 F to 125 F (0 C to 52 C) Refer to Engineering Section for details. Approvals Most are UL listed, CSA certified, and meet applicable CE directives. Contact ASCO for details. Important: Explosionproof Catalog Numbers EF8210W, EF8220, EF8221W, and EF8263 (except ) are not UL listed. They are suitable for Types & 7 (A-D), and 9 (E, F, & G for Class F; E for class coils) only, and have a temperature range code of T3B (Class F) or T3A (Class ). 253
2 2/2 Specifications (English units) Pipe Size (in) Orifice Size (in) Cv Flow Factor Operating Pressure Differential (psi) ot Water Max. Fluid Temp. F ot Water AC Watt Rating/ Class of Coil Insulation Min. Max. AC Max. DC AC DC Catalog Number Const. Ref. AC DC OT WATER SERVICE ONLY - NORMALLY CLOSED (Closed when de-energized), EPDM Diaphragm 3/8 5/ G093W /F 11.6/F 3/8 5/ G001W /F 11.6/F 1/2 5/ G09W S /F 11.6/F 1/2 5/ G002W S /F 11.6/F 3/ 3/ G095W S /F 11.6/F 3/ 3/ G009W S /F 11.6/F OT WATER SERVICE ONLY - SLOW CLOSING - NORMALLY CLOSED (Closed when de-energized), EPDM Disc 3/8 9/ G001W /F - 1/2 9/ G003W /F - 3/ 3/ G005W /F G007W /F - 1 1/ 1 1/ G009W /F - 1 1/2 1 1/ G011W 0 6.1/F / G013W 1 6.1/F - 2 1/2 1 3/ G015W 2 6.1/F - OT WATER SERVICE ONLY - SLOW CLOSING - NORMALLY OPEN (Open when de-energized), EPDM Disc 3/8 9/ G021W /F - 1/2 9/ G023W /F - 3/ 3/ G025W 16.1/F G027W /F - 1 1/ 1 1/ G029W /F - 1 1/2 1 1/ G031W /F / G033W /F - 2 1/2 1 3/ G035W /F - Operating Pressure Differential (psi) Max. Fluid Temp. F Watt Rating/Class Pipe Orifice Cv Max. AC Max. DC AC DC Stainless Steel Body of Coil Insulation Size Size Flow (in) (in) Factor Min. ot Water ot Water ot Water ot Water Catalog Number Const. Ref. Catalog Number Const. Ref. AC DC STEAM/OT WATER SERVICE - DIRECT ACTING - NORMALLY CLOSED (Closed when de-energized), Stainless Steel Seat, EPDM, or PTFE Disc 1/ 1/ / - 1/ 1/ / 1/ 5/ / - 1/ 7/ / - 1/ 9/ / - 3/8 1/ / - 3/8 5/ / - 3/8 7/ / - 3/8 9/ / - STEAM/OT WATER SERVICE - PILOT OPERATED - NORMALLY CLOSED (Closed when de-energized) 1/ 3/ G /F - 1/ 3/ G / - 3/8 3/ G /F - 3/8 3/ G / - 3/8 1/ G /F - 3/8 1/ G /F 15.6/ 3/8 1/ G / 15.6/ 3/8 5/ G /F - 1/2 3/ G /F - 1/2 3/ G / - 1/2 1/ G / - 1/2 5/ G G /F - 1/2 5/ G / - 1/2 1/ G /F - 1/2 1/ G /F 15.6/ 1/2 1/ G / 15.6/ 25
3 2/2 Specifications (English units continued) Pipe Size (in) Orifice Size (in) Cv Flow Factor Operating Pressure Differential (psi) Max. Fluid Temp. F Max. AC Max. DC AC DC Stainless Steel Body Watt Rating/Class of Coil Insulation Min. ot Water ot Water ot Water ot Water Catalog Number Const. Ref. Catalog Number Const. Ref. AC DC STEAM/OT WATER SERVICE - PILOT OPERATED - NORMALLY CLOSED (Closed when de-energized) 3/ 5/ G /F - 3/ 5/ G / - 3/ 3/ G095 S /F - 3/ 3/ G /F - 3/ 3/ G /F 15.6/ 3/ 3/ G / 15.6/ 3/ 3/ G / - 3/ 1/ G / - 3/ 1/ G / G /F G /F G / G /F G / / - 1 1/ 1 1/ G /F - 1 1/ 1 1/ G / - 1 1/2 1 1/ G /F - 1 1/2 1 1/ G / / G /F / G / - 2 1/2 1 3/ G015 ƒ /F - 2 1/2 1 3/ G033 ƒ / - STEAM SERVICE - DIRECT ACTING, STRAIGT-TROUG DESIGN - NORMALLY CLOSED (Closed when de-energized) 3/8 1/ G / - 3/8 3/ G / - 1/2 1/ G / - 1/2 3/ G / - 3/ 3/ G / - 3/ 1/ G / - STEAM SERVICE - DIRECT ACTING, STRAIGT-TROUG DESIGN - NORMALLY OPEN (Open when de-energized) 3/8 1/ G / - 3/8 3/ G / - 1/2 1/ G / - 1/2 3/ G / - 3/ 3/ G / - 3/ 1/ G / - STEAM/OT WATER SERVICE - PILOT OPERATED - NORMALLY OPEN (Open when de-energized) 3/8 9/ G / - 1/2 9/ G / - 3/ 3/ G / G / - 1 1/ 1 1/ G / - 1 1/2 1 1/ G / / G / - 2 1/2 1 3/ G105 ƒ /F - Once opened at higher pressure, valve will remain open to 3 psi at inlet. 0 psi on AC construction, 1/ psi on DC construction. EPDM disc. Not CSA certified. ƒ Not CSA certified for water. Ambient temperature range 32 F - 10 F; Ambient temperature range 32 F - 77 F S Valve available with lead-free brass body and bonnet using suffix LF. The term Lead-Free for brass materials is defined by SDWA 117 as having a maximum weighted average lead content of 0.25% on the wetted surface area. 255
4 2/2 Specifications (Metric units) Operating Pressure Differential (bar) Max. Fluid Temp. C Pipe Orifice Kv Flow AC Watt Rating/ Size Size Factor ot Water ot Water Class of Coil Insulation (in) (mm) (m 3 /h) Min. Max. AC Max. DC AC DC Catalog Number Const. Ref. AC DC OT WATER SERVICE ONLY - NORMALLY CLOSED (Closed when de-energized), EPDM Diaphragm 3/ G093W /F 11.6/F 3/ G001W /F 11.6/F 1/ G09W S /F 11.6/F 1/ G002W S /F 11.6/F 3/ G095W S /F 11.6/F 3/ G009W S /F 11.6/F OT WATER SERVICE ONLY - SLOW CLOSING - NORMALLY CLOSED (Closed when de-energized), EPDM Disc 3/ G001W /F - 1/ G003W /F - 3/ G005W /F G007W /F - 1 1/ G009W /F - 1 1/ G011W 0 6.1/F G013W 1 6.1/F - 2 1/ G015W 2 6.1/F - OT WATER SERVICE ONLY - SLOW CLOSING - NORMALLY OPEN (Open when de-energized), EPDM Disc 3/ G021W /F - 1/ G023W /F - 3/ G025W 16.1/F G027W /F - 1 1/ G029W /F - 1 1/ G031W /F G033W /F - 2 1/ G035W /F - Operating Pressure Differential (bar) Max. Fluid Temp. C Pipe Orifice Kv Flow Watt Rating/Class Size Size Factor Max. AC Max. DC AC DC Stainless Steel Body of Coil Insulation (in) (mm) (m 3 /h) Min. ot Water ot Water ot Water ot Water Catalog Number Const. Ref. Catalog Number Const. Ref. AC DC STEAM/OT WATER SERVICE - DIRECT ACTING - NORMALLY CLOSED (Closed when de-energized), Stainless Steel Seat, EPDM, or PTFE Disc 1/ / - 1/ / 1/ / - 1/ / - 1/ / - 3/ / - 3/ / - 3/ / - 3/ / - STEAM/OT WATER SERVICE - PILOT OPERATED - NORMALLY CLOSED (Closed when de-energized) 1/ G /F - 1/ G / - 3/ G /F - 3/ G / - 3/ G /F - 3/ G /F 15.6/ 3/ G / 15.6/ 3/ G / - 1/ G /F - 1/ G / - 1/ G / - 1/ G G /F - 1/ G / - 1/ G /F - 1/ G /F 15.6/ 1/ G / 15.6/ 256
5 2/2 Specifications (Metric units continued) Operating Pressure Differential (bar) Max. Fluid Temp. C Pipe Orifice Kv Flow Watt Rating/Class Size Size Factor Max. AC Max. DC AC DC Stainless Steel Body of Coil Insulation (in) (mm) (m 3 /h) Min. ot Water ot Water ot Water ot Water Catalog Number Const. Ref. Catalog Number Const. Ref. AC DC STEAM/OT WATER SERVICE - PILOT OPERATED - NORMALLY CLOSED (Closed when de-energized) 3/ G /F - 3/ G / - 3/ G095 S /F - 3/ G /F - 3/ G /F 15.6/ 3/ G / 15.6/ 3/ G / - 3/ G / - 3/ G / G /F G /F G / G /F G / / - 1 1/ G /F - 1 1/ G / - 1 1/ G /F - 1 1/ G / G /F G / - 2 1/ G015 ƒ /F - 2 1/ G033 ƒ / - STEAM SERVICE - DIRECT ACTING, STRAIGT-TROUG DESIGN - NORMALLY CLOSED (Closed when de-energized) 3/ G / - 3/ G / - 1/ G / - 1/ G / - 3/ G / - 3/ G / - STEAM SERVICE - DIRECT ACTING, STRAIGT-TROUG DESIGN - NORMALLY OPEN (Open when de-energized) 3/ G / - 3/ G / - 1/ G / - 1/ G / - 3/ G / - 3/ G / - STEAM/OT WATER SERVICE - PILOT OPERATED - NORMALLY OPEN (Open when de-energized) 3/ G / - 1/ G / - 3/ G / G / - 1 1/ G / - 1 1/ G / G / - 2 1/ G105 ƒ /F - Once opened at higher pressure, valve will remain open to 0.2 bar at inlet. 0 bar on AC construction, 0.02 bar on DC construction. EPDM disc. Not CSA certified. ƒ Not CSA certified for water. Ambient temperature range 0 C - 60 C; Ambient temperature range 0 C - 25 C S Valve available with lead-free brass body and bonnet using suffix LF. The term Lead-Free for brass materials is defined by SDWA 117 as having a maximum weighted average lead content of 0.25% on the wetted surface area. 257
6 2/2 Dimensions inches (mm) Const. Ref. K L P W 1 in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm L L Const. Ref. 1, 2, 3 K ANPT PIPE TREAD (2 PLACES) Const. Ref., 9, 12 K P P NPT BOT ENDS W W 1/2 NPT Const. Ref. 8, 50, 51, 52 Const. Ref. 5, 7, 10, CONDUIT 1/2" NPT K P FLOW L PIPE SIZE 2 PLACES 1 EAC END Ø W 258
7 2/2 Dimensions inches (mm) Const. Ref. K L P W 6 in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm * Valves must be mounted with solenoid vertical and upright. Const. Ref. 6, 11, 13, 29 Const. Ref. 19* Const. Ref. 20* Const. Ref. 1-16, 23-25, 5-9, 53 (BOLT PATTERN MAY VARY) 259
8 2/2 Dimensions inches (mm) Const. Ref. K L P W 21 in mm in mm in mm in mm in mm in mm in mm in mm Const. Ref. 17, 18, 26, 27, 38-2 Const. Ref. 28 Const. Ref. 30 Const. Ref. 31 Const. Ref. 21, 22, 36, 3, K P L W 260
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
More information% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power
.55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard
More information2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More informationFour-Way Valves. Accessories TABLE OF. Rotary and Smart. Actuator Motors
TABLE OF CONTENTS 389 We stock more than 2,000 different ASCO solenoid valves, repair kits, and replacement coils. What we don t stock, we can usually get from the factory within 5 working days! As the
More informationSolenoid valves 2/2-way direct-operated Type EV210A
Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral
More information4 Nuclear Catalog. Nuclear Products Qualified to IEEE Specifications. Solenoid Valves. Check Valves. Pressure & Temperature Switches
4 Nuclear Catalog Nuclear Products Qualified to IEEE Specifications Solenoid Valves Check Valves Pressure & Temperature Switches Hydramotor Actuators www.ascovalve.com Index Engineering Information 2-8
More informationSolenoid valves Type EVU
Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot
More informationWELCOME TO MAGNATROL
Catalog 6 BULLETIN 6-INDEX WELCOME TO MAGNATROL Process Control Solenoid Valves For Water Oil Air Gas Steam Cryogenics Vacuum Solvents Brine Oxygen Corrosive Fluids Magnatrol Valve Corp. Established 1936
More information3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationCoil Classification: Class F standard, Class H available Class B standard on V9xx models
Direct Acting & Pilot Operated Valves 1/8" - 1/2" General Description: Direct Acting and Pilot Operated valves are used in applications for actuation of double acting cylinders and piloting of larger control
More informationMorrison Bros. Co. General Product Specifications
Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage
More informationValve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL
More informationVSO MAX HP High Flow Proportional Valve
VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationCentro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationSQUARE D INDUSTRIAL CONTROL PRODUCTS
SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and
More informationBaumann 24003 3 Way Bronze or Stainless Steel Control Valve
Product Bulletin D1039X012 24003 Valve Baumann 24003 3 Way Bronze or Stainless Steel Control Valve 3 Way Rugged Industrial Control Valve For Mixing and Diverting Applications The Baumann 24003 3 way control
More informationSporlan V-Series Ruby Seat Solenoid Valves
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Sporlan V-Series Ruby Seat Solenoid Valves RACE Catalogue 30-10-8 UK,
More informationStandard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve
Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective
More informationScraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
More informationSolenoid and Air Operated Valves. Supporting Fleet Operations for Over 60 Years
4 Solenoid and Air Operated Valves Supporting Fleet Operations for Over 60 Years This catalog describes solenoid and air operated valves, representative of those manufactured by ASCO Valve, Inc. to meet
More informationBaumann 81000 Mikroseal Control Valve
Product Bulletin D103340X012 Baumann 81000 Mikroseal Control Valve The Baumann 81000 Mikroseal control valve (figures 1 and 2) is excellent for throttling of liquid or gaseous media, particularly where
More informationMustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
More information3/2-way Mini Solenoid Valve
3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug
More informationPilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)
OPTIONS: USE: AVAILABLE MODELS: Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel) DESCRIPTION The ADCA PRV47 pilot operated pressure reducing valves are designed for use on steam,
More informationsolenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid
2- and 3-way Solenoid Valves for Gas and Liquid SV10: Vacuum to 3000 psig SV430: Vacuum to 3000 psig SV20: Vacuum to 6000 psig SV460: Vacuum to 6000 psig SV30: Vacuum to 3000 psig Circle Seal Controls
More information4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
More informationApplication Feature Valve Nominal Liquid Capacity R-22 (in tons)*
EMERSON CLIMATE TECHNOLOGIES-Solenoid Valves & Coils Quick Select Guide Applications Application Feature Valve Nominal Liquid Capacity R-22 (in tons)* Nominal Liquid Capacity R-410A (in tons)* Liquid Line
More informationPRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
More informationBaumann 24000 Little Scotty Bronze Control Valve
24000 Valve Product Bulletin Baumann 24000 Little Scotty Bronze Control Valve Baumann Little Scotty industrial control valves are intended for general utility service in pressure, flow, and temperature
More informationElectro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N
More information3/2- and 2/2-way cartridge valve type BVE
3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type
More informationBERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features
Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable
More informationB-Series Switches Pressure, Differential Pressure & Hydraulic
FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment
More information2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
More informationMiniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC
8mm Solenoid Valve Typical Applications Portable Equipment Blood Pressure Monitoring Wound Therapy Air and Oxygen Delivery Sensor Zeroing Product Specifications Mechanical Valve Type: 3-Way, Solenoid-actuated
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationXE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY
XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to
More informationball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves
2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating
More information9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog
9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G Catalog January 07 Contents Commercial Pressure Switches Pressure Switches b Selection..............................................
More informationS GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR
MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,
More informationAPI Flanged Safety Relief Valves Series 526 CATALOG
API Flanged Safety Relief Valves Series 26 CATALOG The-Safety-Valve.com 1 Valve finder How to find the right product group High operating to set pressure ratio, high backpressure or low total height? Yes
More informationElectrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports
More informationBERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features
Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive
More informationREGULATORS D& HD Series
Watson McDaniel reserves the right to change the designs and/or materials of its products out notice. 2002 Watson McDaniel Company Ductile Iron body - HD Series Full port strainer & blowdown valve on pilot
More informationSingle sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
More informationBaumann 87000 Flexsleev Sanitary Control Valve
Product Bulletin D103345X012 Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve (figures 1 and 2) is excellent for throttling high purity liquid or gaseous media commonly found
More information! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes
More informationHENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)
HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL) The oil level regulator controls the oil level in the compressor crankcase with a float operated valve. Oil level regulators are designed to attach
More informationSTC 3S012-020-A Series Solenoid Valves
STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,
More informationSOLENOID VALVE FOR REFRIGERATING SYSTEMS
SOLENOID VALVE FOR REFRIGERATING SYSTEMS FROM UALITY OUR NATURAL DEVELOPMENT Achieved the goal of fi fty years working in the industry of Refrigeration and Air Conditioning, Castel uality Range of Products
More informationPrecision Solenoid Valves
Precision Solenoid Valves Solenoid Valves for gas General Purpose Valves Specialty Solenoid Valves n Didn t see what you re looking for? Let us review your requirements and chances are we can help solve
More informationSystem 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8
System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures
More informationModel DE-3 Air Release Head
SPECIFICATIONS MEASUREMENT SOLUTIONS Model Air Release Head Bulletin SS03037 Issue/Rev. 0.2 (10/15) We put you first. And keep you ahead. SMITH METER AIR ELIMINATOR The Smith Meter Model Air Release Heads
More informationThermostatic valve Type AVTA
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The
More informationCartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)
Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers
More informationVC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge
More informationPOWER PULSE VALVES remote pilot threaded or Quick Mount connection 3/4 to 1 1/2
POWR PULS VLVS pilot threaded or Quick Mount 3/4 to 1 1/2 N 2/2 Series 353 TURS The piston cartridge pulse valves are especially designed for dust collector service applications, combining high flow, long
More informationservo-controlled 3-WaY vacuum solenoid valves WiTH
servo-controlled 3-WaY vacuum solenoid s WiTH low absorption electric coil The 3-way vacuum solenoid s in this series feature two positions with pneumatically pilot-operated conical shutters. They can
More informationExplosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
More information12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations
12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling
More informationSOLENOID VALVES AND PNEUMATIC VALVES
2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the
More informationMTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
More information4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems
Dynamic Solutions Leadership and Innovation in Valve Products and Valve Systems At ASCO, Valve Performance Begins and Ends With People 4 First of all, it begins with the people we serve. It is from them
More informationSPST-NO SPDT DPST-NO DPDT
PCB Relay Next-generation PCB Relay Available in 2 Models Low profile:. mm max. in height Contains no lead inside and features cadmium-free contacts ensuring environment-friendly use. Conforms to VDE0
More informationStainless Steel Valves For the Sanitary Industries
www.swagelok.com Stainless Steel Valves For the Sanitary Industries Sanitary ball valves Manual and pneumatically actuated butterfly valves Disk and ball check valves ir blow check valves ir relief valves
More informationAZ420 MINIATURE GENERAL PURPOSE RELAY
MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 0 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available
More informationSTC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting
STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting Female NPT Thread 3/8 OD Tube 3/8 Push-In Fitting 2P050 Series Solenoid Valve Specifications Valve Model 2P050-1/4 2P050-3/8
More informationModel 4418F. www.amot.com. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve
High Pressure Control Valve Model 4418F Overview The 4418F has been designed specifically for use as an air start valve for diesel engines or as a fuel shut-off valve for gas turbine applications. Its
More informationType 3353 Angle Seat Valve
Type 3353 Angle Seat Valve Application On/off valve with pneumatic piston actuator Nominal size DN 15 to 50 (NPS ½ to 2) Nominal pressure PN Temperature range 10 to 180 C Globe valve with an angle seat
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationMAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure
MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4
More information5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm
More informationType 92S Pilot-Operated Steam Regulator
Type 92S Pilot-Operated Steam Regulator Introduction The Type 92S steam regulator is piston actuated for high cycle steam service which includes a Type 6492L, 6492H or pilot (see Figure 1). These pilots
More information2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications
Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?
More information3 Port Solenoid Valve
Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large
More informationIEC Connectors. Introduction
Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings
More informationFLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES
01D351-GB FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES DOLOMIT FLOAT SWITCHES The DOLOMIT float switches find application in liquid level control in tanks and wells; they require connection
More informationVALVES FOR REFRIGERATING SYSTEMS
VALVES FOR REFRIGERATING SYSTEMS FROM QUALITY OUR NATURAL DEVELOPMENT Achieved the goal of fi fty years working in the industry of Refrigeration and Air Conditioning, Castel Quality Range of Products is
More informationONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.
ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)
More informationBURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationCable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
More informationRMF Engineering 23 05 23
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
More informationRated Burst Pressure 200 Series: 2.5 : 1 H200 Series: 4 : 1
200 Series 0 to 3000 psig heck Valves H200 Series 0 to 6000 psig heck Valves Features & enefits Quick opening/positive closing Provides a wide range of adaptability Large flow capacity The patented sealing
More informationUM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves
U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking
More informationSolenoid Valves and Their Importance in Refrigeration Systems. October 2007
Solenoid Valves and Their Importance in Refrigeration Systems October 2007 Overview Introduction Solenoid valves play an important role within refrigeration and air conditioning systems, controlling the
More informationISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24
Type series booklet 8448.1/2-EN--US ISORIA Centered disc butterfly valves with AMRING elastomer liner 240 PSI: 1½ to8 150 PSI : 10 to 24 Design in accordance with ISO 10631 Manual, electrical, pneumatical
More informationIntroduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D-193. www.usa.siemens.com/hvac
Introduction Angle/Flared/Sequence/Changeover Service D-193 In this section, you will find flared, angled, sequence and changeover valves for use in service applications. D-194 Need additional assistance?
More informationThermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special
More informationNEW! Typical Applications. Motor controls Thermostatics Portable tools Air Conditioner. Materials
TF2 Series Miniature Snapacting Switches NEW! Features/Benefits Broad range of operating forces Ratings up to 10 AMPS Wide variety of actuator styles Quick connect terminations Typical Applications Motor
More informationResidential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
More informationCompact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
More informationBERMAD Waterworks. High Pressure, Surge Anticipating Control Valve. 800 Series. Model 835-M. Features and Benefits. Major Additional Features
High Pressure, Surge Anticipating Control Valve Eliminates surge in all pumping systems: Booster & deep well, single & variable speed Eliminates surge in all distribution networks: Municipal, high-rise
More informationSelf-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Application Pressure regulators for set points from 5 mbar to 28 bar Valves in nominal sizes DN 15 to 100 Nominal pressures
More information2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow
2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description
More information