GENERAL PURPOSE (NEMA 4), NORMALLY CLOSED .9130C G NPT / G
|
|
- Norah Holland
- 7 years ago
- Views:
Transcription
1 2 Way (2/2) DIAPHRAGM VALVE HERION BRASS OR STAINLESS STEEL Brochure N-300 SPECIFICATIONS: Normally closed or normally open for air, oil or water 1),2) Port Sizes: 1/4 to 2 inch Flow Direction: One Way Fluid Temperature: 5º to 195ºF (-10º to 90ºC) Environmental Temp: 5º to 120ºF (-10º to 50ºC) Installation: Optional; solenoid should be vertical for maximum life Body Material: Brass or Stainless Steel Seal Material: Buna N (NBR), EPDM, FKM (VITON) a a b A b P Normally Closed GENERAL PURPOSE (NEMA 4), NORMALLY CLOSED Orifice Operating Pressure Cv Weight Port Brass Valve Stainless Solenoid Port Size Steel Valve Size (mm) Min Max (psi) Thread DC or AC NPT / G NPT / G NPT / G NPT / G NPT G NPT / ) G NPT / ) G NPT ) G ) For dirty or contaminated fluids insertion of a strainer is recommended 2) For liquids the maximum allowable viscosity is 25 centistokes (mm 2 /s) 3) For normally open configuration, see high pressure version
2 EXPLOSION PROOF (NEMA 4X, 7 & 9), NORMALLY CLOSED Orifice Operating Cv Weight Port Brass Valve Stainless Steel Solenoid Port Size Pressure (psi) Thread Valve Size (mm) Min Max DC or AC NPT EP EP 1/ G EP EP NPT EP EP 3/ G EP EP NPT EP EP 1/ G EP EP NPT EP EP 3/ G EP EP NPT EP EP G EP EP NPT EP 1 1/ ) G EP NPT EP 1 1/ ) G EP NPT EP ) G EP 6) 150 psi max in normally open configuration X=6 for DC, X=7 for AC HIGH PRESSURE (SIZES LARGER THAN 1 ) Orifice Size Operating Pressure (psi) Cv Weight Port Solenoid Port Size Brass Valve (mm) Min Max Thread DC or AC NPT HP 1 1/ ) C G HP NPT HP 1 1/ ) C G HP NPT HP ) C G HP 6) 150 psi max in normally open configuration HOT WATER & STEAM (300º F), NORMALLY CLOSED Orifice Size Operating Pressure (psi) Cv Weight Port Brass Valve Solenoid Port Size (mm) Min Max Thread DC or AC NPT / G NPT / C G NPT / C G NPT / C G NPT C G
3 OPTIONS FEATURE Normally Open Manual Override (Currently not available in stainless steel) FKM / Viton Seal (Diaphragm) Maximum Fluid Temperature: 230ºF (110ºC) EPDM Seal (Diaphragm) Maximum Fluid Temperature: 230ºF (110ºC) Operating Pressure: 4.5 to 150 psi (.3 to 10 bar) PART NUMBER CHANGE XX XXX 01.XXXX XX XXX 02.XXXX XX XXX 03.XXXX XX XXX 14.XXXX MOUNTING BRACKET KITS Mounting Bracket Kits are available for the Click-On valves in this brochure. The mounting brackets provide easy and expedient mounting options for space conscious applications. Each mounting bracket kit includes 1 bracket and 2 valve-bracket mounting bolts. Dimensional information is shown below. (all dimensions in millimeters). Nominal Size (inch.) Model Number A B C D E F G H 1/4, 3/8, 1/ / /4, 1 1/
4 GENERAL PURPOSE APPLICATIONS Solenoid 9130C, 9150C: These solenoids include a mating connector. Together, the molded coil and connector combination complies with NEMA 4 specifications. A spring clip secures the solenoid / connector assembly to the valve. The electrical connection is made through the three integral solenoid prongs (2 power, 1 ground), once the solenoid is plugged into the connector. The connection is then secured by tightening the screw provided with the unit. Consult Herion for solenoid voltages or arrangements not found in this brochure. General Purpose Connector: A standard cable clamp connector is included with the and.9150c solenoid. Optional connectors may be selected from the table below. Standard Cable Clamp 1/2 NPT Optional Connector LED Indicator Light Connector 24 VAC, VDC 120 VAC 220 VAC See Figure 1 for dimensions. Solenoids 3826 & 3827: HAZARDOUS DUTY, EXPLOSION PROOF (for North America) Electric Schematic Designed to be used with 1/2 NPT mating conduit. These solenoids meet Type 4X, 7, 9 enclosure requirements and are rated for a 100% duty cycle. They comply with insulation class H (180º C) and are for use in Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G, hazardous locations. The solenoids are attached to the valve with a solenoid retaining nut. The electrical connection is made through 3 wire leads, each 18 long. The two red leads are for power; the third wire (green with yellow stripe) is the ground. Note: Power leads (red) are not polarity sensitive. See Figure 2 for dimensions. Solenoid 9136: HAZARDOUS DUTY, EXPLOSION PROOF (for Europe) For applications requiring conformance to the international CENELEC hazardous area ( explosion proof ) approval standards, the Click-on solenoid system offers solenoid model number The particular CENELEC class rating specification for this solenoid is EEx mii T4. The m designation specifies an encapsulated solenoid, which features a 3 meter long cable assembly in place of the standard DIN style connector, to conform to the hazardous area design requirements. This particular classification specifies that this solenoid is permissible for use in all designated gas groups, and will reach a maximum surface temperature of 135º C (275º F). 4
5 ELECTRICAL DATA Solenoid Number Power Consumption DC (W) AC (VA) Steady Inrush Max. Temperature Temp. Fluid Code Ambient Location Approvals ºF (AC) 120ºF (AC) 105ºF (DC) CERTIFIED LR C ºF (AC) 120ºF (AC) CERTIFIED ºF 120ºF ºF T3A 140ºF (120 VAC) 16 (220 VAC) 180ºF T3C 140ºF CERTIFIED LR APPROVED File2Z2A6.AE CLASS I DIVISION 1,2 GROUPS A,B,C,D CLASS II DIVISION 1,2 GROUPS E, F,G CLASS III DIVISION 1, ºF T4 104ºF STANDARD VOLTAGES Solenoid Number Standard Voltages VAC VDC 50 Hz 60 Hz 12V 110V 230V 120V 220V.9150C 110V 230V 120V 220V V 230V 120V 220V V V 120V 220V 240V 110V 230V 120V 220V Contact factory for non-standard voltages. 5
6 LOW POWER SOLENOID COIL DESIGN (2 WATT) Solenoid With the demand for lower power consumption (particularly for use in relay and PLC control applications), the Click-on solenoid system offers solenoid model number This solenoid design features an inherently low power consumption design of 2 watts in the VDC configuration, and 4 VA in the VAC configuration. Please note in sizes greater than 1 (1-1/4, 1-1/2, and 2 ), the maximum pressure achievable with this low power solenoid is 85 psi (instead of the usual 230 psi with solenoid 9150C, or 150 psi with solenoid 9130C). LATCHING COIL DESIGN Function: A permanent magnet is mounted in the core tube so that after switching the valve from normally closed to open with a short pulse of power (typically 30 ms.), the current consumption goes to zero. To close the valve a voltage with reverse polarity is applied to neutralize the magnetic force. Contact factory for more information. XX XXX XX XXX (For DC applications only in either 6 VDC, 12 VDC or 24 VDC). PARTS LIST AND IDENTIFICATION 101 Valve body 102 Valve cover *103 Diaphragm 104 Socket head cap screw *105 Pressure spring 400 Solenoid 701 Core tube *702 O-Ring 703 Screw piece *704 Pressure spring *705 Core 706 Spring clip 707 O-Ring 1400 Connector *Parts marked with an asterisk are contained in the spare parts kit. 6
7 DIMENSIONAL INFORMATION Fig. 1 General Purpose BRASS SST STEAM Valve 1) HP.9150C HP.9150C HP.9150C HP.9150C HP.9150C HP.9150C Note: All dimensions in millimeters. 1) See Hot Water and Steam (300º F) chart on page 2. B H H1 L Port Size R 1/4 NPT G 1/4 3/8 NPT G 3/8 1/2 NPT G 1/2 3/4 NPT G 3/4 1 NPT G 1 1 1/4 NPT G 1 1/4 1 1/2 NPT G 1 1/2 2 NPT G 2 1 1/4 NPT G 1 1/4 1 1/2 NPT G 1 1/2 2 NPT G 2 7
8 DIMENSIONAL INFORMATION Fig. 2 Hazardous Duty BRASS SST EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP! x = 6 for D.C., x = 7 for A.C. Note: All dimensions in millimeters. H H1 L Port Size R 1/4 NPT G 1/4 3/8 NPT G 3/8 1/2 NPT G 1/2 3/4 NPT G 3/4 1 NPT G 1 1 1/4 NPT G 1 1/4 1 1/2 NPT G 1 1/2 2 NPT G 2 EU Manufacturer s Declaration: As defined in EU Machinery guideline 89/392/EEC, Appendix II B. We hereby declare that the diaphragm valves were developed and designed using the following harmonized standards: Note: These diaphragm valves are intended for fitting in a machine. They must not be commissioned until it has been established that the machine as a whole confirms to the EU guideline. EN 292 EN 983 EN Machine Safety Pneumatic Systems Electrical Equipment for Machinery Note on EU guideline: The valves shall be provided with an electrical circuit which ensures the limits of the harmonized standards EN and EN are observed, and hence the requirements of the Electromagnetic Compatibility Guideline (89/336/EEC) satisfied. HERION USA Inc. 176 Thorn Hill Road Warrendale PA Phone: Fax: sales@herionusa.com Rev. 4/2002
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
More information3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More information4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationCable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
More informationSingle sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
More information% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power
.55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard
More informationScraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
More information2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
More informationSolenoid valves 2/2-way direct-operated Type EV210A
Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationElectrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports
More information2/2 and 3/2 Way Size 6 Seat Valves
2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08
More informationRPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007
Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid
More informationCentro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationSTC 3S012-020-A Series Solenoid Valves
STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,
More informationFluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.
Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power
More information3/2- and 2/2-way cartridge valve type BVE
3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationHow To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More information3/2-way pneumatic cartridge solenoid valve
3/2-way pneumatic cartridge solenoid valve Compact design with 11 mm width per station Orifices from 0.5 mm (9 bar) to 1.2 mm (1.5 bar) High durability and reliability Low power consumption, as well as
More informationSolenoid Operated Directional Valves
INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SD-2B-115A-35 SDS-2H-12D-35 S-2B-115A-35 Features High Flow/ High Pressure: Up to 25 gpm / 5000 psi working
More informationEXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
More informationVSO MAX HP High Flow Proportional Valve
VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationPlastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
More informationSolenoid Operated Directional Valves
INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SF-2C-115A-35 S-1AY-12D-35 SD-2C-12D-35 Features High Flow/ High Pressure: Up to 40 gpm / 5000 psi working pressure*.
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationtype V46, solenoid or pneumatic operated
SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function
More informationSTC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting
STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting Female NPT Thread 3/8 OD Tube 3/8 Push-In Fitting 2P050 Series Solenoid Valve Specifications Valve Model 2P050-1/4 2P050-3/8
More informationCartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)
Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers
More informationSolenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
More informationSOLENOID VALVES AND PNEUMATIC VALVES
2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the
More informationElectro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N
More informationSystem 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8
System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures
More information3 Port Solenoid Valve
Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large
More informationFluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
More information3/2-way Mini Solenoid Valve
3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug
More informationsolenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid
2- and 3-way Solenoid Valves for Gas and Liquid SV10: Vacuum to 3000 psig SV430: Vacuum to 3000 psig SV20: Vacuum to 6000 psig SV460: Vacuum to 6000 psig SV30: Vacuum to 3000 psig Circle Seal Controls
More informationE4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51
83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationAT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
More informationBURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief
More informationSensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm
Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders
More informationSeries 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS
Series 427 1/16 DIN Multi-Mode Bar Graph Display Timer PRODUCT HIGHLIGHTS Digital Setting with 0.1% Accuracy Unique LED Bargraph Indicates Time Cycle in 20% Increments 8 Field Selectable Modes of Operation
More informationCoil Classification: Class F standard, Class H available Class B standard on V9xx models
Direct Acting & Pilot Operated Valves 1/8" - 1/2" General Description: Direct Acting and Pilot Operated valves are used in applications for actuation of double acting cylinders and piloting of larger control
More information4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationElectronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
More information2/2 & 3/2 Solenoid operated valves
2/2 & 3/2 Solenoid operated valves Operation Series Page no. Function 2/2 3/2 Body material Stainless steel Brass Grey cast iron Plastic resin PVDF Solenoids IP Protection class IP65 (with connector) Buschjost
More informationSolenoid valves Type EVU
Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot
More informationSITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
More informationSQUARE D INDUSTRIAL CONTROL PRODUCTS
SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and
More informationModel DE-3 Air Release Head
SPECIFICATIONS MEASUREMENT SOLUTIONS Model Air Release Head Bulletin SS03037 Issue/Rev. 0.2 (10/15) We put you first. And keep you ahead. SMITH METER AIR ELIMINATOR The Smith Meter Model Air Release Heads
More informationMono-Block II Installation & Operation Manual
Mono-Block II Installation & Operation Manual Enraf Fluid Technology UK, Ltd. Enraf Fluid Technology USA, Inc. 6 Pennant Park, Standard Way 2000 Northfield Court Fareham, Hampshire, England PO16 8XU Roswell,
More informationAdvantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
More informationMTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
More informationLine-Mounted Valves L Series
Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series
More informationCONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
More information! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes
More informationMiniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC
8mm Solenoid Valve Typical Applications Portable Equipment Blood Pressure Monitoring Wound Therapy Air and Oxygen Delivery Sensor Zeroing Product Specifications Mechanical Valve Type: 3-Way, Solenoid-actuated
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
More information3 Port Solenoid Valve
ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.
More informationControl- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
More informationBERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features
Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable
More informationSystem 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
More informationSolenoid Valve Type 3962
Solenoid Valve Type 362 x d, x em or without explosion protection, for controlling pneumatic actuators General The Type 362 Solenoid Valve ensures a high level of operational reliability for controlling
More informationArt.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
More informationOperating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1
Operating Instuctions Shaking device SV 14 / 22 SV 29 / 45 page 1 General notes, safety notes, notes on electrical equipment and electromagnetic compatibility, as well as notes on maintenance of the unit
More informationFlow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
More informationPrecision Solenoid Valves
Precision Solenoid Valves Solenoid Valves for gas General Purpose Valves Specialty Solenoid Valves n Didn t see what you re looking for? Let us review your requirements and chances are we can help solve
More informationInrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.
Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the
More informationIOM SERIES 820-E/P Electro-Pneumatic Positioner
FLUID CONTROL DIVISION Parker Hannifin Corporation 95 Edgewood Avenue New Britain, CT 06051 Telephone (860) 827-2300 IOM SERIES 820-E/P Electro-Pneumatic Positioner INSTALLATION, OPERATING & MAINTENANCE
More informationOperating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
More informationStandard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve
Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective
More informationHow To Power A Schen
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
More informationData Sheet PS1B Pressure Switch
Data Sheet PS1B Pressure Switch Main Features Pressure Ranges 0 to 6 up to 0 to 600 bar (gage) Electrical Connection G 1/4 A DIN 3852-E or -A Pressure Connection Output Signal M12-4 Pin 4-20 ma, Programmable
More informationPilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)
OPTIONS: USE: AVAILABLE MODELS: Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel) DESCRIPTION The ADCA PRV47 pilot operated pressure reducing valves are designed for use on steam,
More informationMaterial: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
More informationSELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
More information5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More informationVC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationMini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
More informationSERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR 032-044-000 032-045-000 WARNING 12-32 VDC
SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR 032-044-000 032-045-000 } 12-32 VDC Specifications 032-044-000 and 032-045-000 WARNING Hazardous voltage. This Leak Detector is an electrical device.
More informationDirectional seated valves type VP 1
Directional seated valves type VP 1 zero leakage, intended for general hydraulic applications and grease lubing systems Flow Q max Operation pressure p max = 15 lpm = 400 bar Individual valve Individual
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informationClear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
More informationFerrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
More information167D Series Switching Valves
June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are
More informationDirectional Control Valves
echnical Information General he D1VW Series directional control valves are highperformance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available in 2 or 3-position
More informationIndustrial Control Power Transformers
Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments
More informationShunt lock function 3066
Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning