MULTI RF MANUAL. Forest Multi remote X64X 2. Forest Multi wall switch LED Forest Multi receiver click-on

Size: px
Start display at page:

Download "MULTI RF MANUAL. Forest Multi remote X64X 2. Forest Multi wall switch LED Forest Multi receiver click-on"

Transcription

1 1 MULTI RF MANUAL CONTENT Forest Multi remote X64X 2 Forest Multi wall switch RF Forest Multi wall switch LED Forest Multi receiver click-on Forest Shuttle S / L receiver programming /1 5 Forest Multi receiver / wall switch for Shuttle M / Forest FMS/BCS Multi receiver programming remote 6 - wiring diagram 7 Tubular motor with build in receiver and electronic limit setting - wiring diagram 8 - programming remote 9 - setting end limits 10 BS double shaft motor 24V programming remote 12 - setting end limits 13

2 2 FOREST MULTI REMOTE X46X TECHNICAL SPECIFICATION: 3V battery CR2430 transmit range indoors max. 30mtr battery life < 3 years working temperature -10 C C frequency MHz modes: manual, timer and dynamic timer (15 minutes + and -) transmit power max. 10mW each channel can control up to 20 receivers / motors selected channel manual/auto/dynamic mode open/up button stop button close/down button channel +/- mode button time button P2 (LEARN) button battery slide (CR2430) SET TIME press mode to set press time for ~7sec. press buttons to press time to press time ~7sec. press time once mode to manual 2 digits will blink change time toggle between until all digits more to finish man on display hours/minutes stop blinking and start clock BEFORE SETTING THE TIMER(S), SET THE CLOCK! SET TIMER (EACH CHANNEL SEPARATE): NOTE: time between button presses max. 10 seconds press mode to select channel press time for press buttons to press time to press mode to switch set mode to ~7sec. hour change open time toggle between to close time auto or dynamic digits will blink hours/minutes press buttons to press time to press time for ~7sec. set to mode change close time toggle between until digits stop auto or dynamic hours/minutes blinking finished

3 3 FOREST MULTI REMOTE X46X MODE EXPLANATION: Mode manual (man): remote can only be used manually. Timer function is switched off. Mode automatic (auto): timer is switched on, only for the selected channel. Select channel 00 (all channels) to engage on all timers. Mode dynamic ( ): same as automatic mode, open and close time will vary + and 15 minutes. FEATURES: When channel select is set to channel 00, all the channels 1 to 15 will respond to open and close. Default timer setting for every channel is: open 06:30AM, close 5:30PM. Dynamic mode: timer will vary open and close time between + and 15 minutes. The first day dynamic mode is used the time will not vary. FREQUENT ASKED QUESTIONS: Q: Clock doesn t start running after setting the time. A: Press time button on the back once more. Q: I can t succeed setting the time or the timer. A: The interval between pressing different button must be within 10 seconds. Q: When I set a timer, the display shows Er:01 A: Time between open-time and close-time must be more than 30 minutes apart. Q: Timer only works on one channel. A: Only the selected channel will work as a timer. Use channel 00 to turn on all timers (all channels). Q: I can t succeed programming a remote / wall switch RF to a receiver A: During programming, keep the remote / wall switch RF close to the receiver (max 0,5 mtr) COLOURS: white gloss white mat wl white mat without logo grey mat wl grey mat without logo black gloss wl black gloss without logo black mat wl black mat without logo BATTERY EMPTY: After changing the battery, only the time must be set. Programmed receivers and timers will stay in memory of remote. Please follow the local regulations for disposal of the empty battery.

4 4 FOREST MULTI WALL SWITCH RF TECHNICAL SPECIFICATION: 3V battery CR2032 battery life < 3 years frequency MHz transmit power max. 10mW transmit range indoor max. 30mtr working temperature -10 C C each channel can control up to 20 receivers P2 buttons (for programming tubular motor) OPEN/UP button STOP button CLOSE/DOWN button channel A channel B battery CR2032 BATTERY EMPTY: After changing the battery, programmed receivers will stay in memory of remote. Please follow the local regulations for disposal of the empty battery. FOREST MULTI WALL SWITCH LED TECHNICAL SPECIFICATION: 12V battery type 27A battery life < 3 years frequency MHz transmit power max. 10mW transmit range indoor max. 30mtr working temperature -10 C C each channel can control up to 20 receivers OPEN/UP button STOP button CLOSE/DOWN button + channel A channel B P2 buttons (for programming tubular motor) BATTERY EMPTY: After changing the battery, programmed receivers will stay in memory of remote. Please follow the local regulations for disposal of the empty battery.

5 5 FOREST MULTI RECEIVER CLICK ON TECHNICAL SPECIFICATION: powered by Shuttle M connect to port 1 of the Forest Shuttle M working temperature -10 C C controlled by Forest Multi Remote and Forest Multi Wall Switch RF control led program button PROGRAMMING REMOTE / WALL CANCEL ONE CHANNEL OF DELETE ALL PREVIOUS PROGRAMMED SWITCH TO RECEIVER: REMOTE / WALL SWITCH REMOTES / WALL SWITCHES: press program button press program button press and hold the program led will light up led will light up button for 10 seconds until led starts blinking hold the remote within 0,5 mtr from receiver. Select channel (1-15) and press open button select channel and press close button led blinks 3 times and will go off led will blink and will go off FOREST SHUTTLE S / L RECEIVER PROGRAMMING To programming a RF remote to a Shuttle S / L, press configuration button 3 times. LED3 is ON. Keep the button pressed for 4 seconds, LED will start blinking for 10 seconds. In these 10 seconds press OPEN button on remote to program the channel to the Shuttle. Same procedure, but press CLOSE instead of OPEN, will erase the programmed channel. configuration button

6 / TECHNICAL SPECIFICATION SHUTTLE M RECEIVER: TECHNICAL SPECIFICATION FMS/BCS RECEIVER: powered by Shuttle M power 230Vac 500W can also be used as wall switch controls one motor cable 0,5mtr can also be used as wall switch cable 3,5mtr terminal max 2,5mm² connect to port 1 of the Forest Shuttle M working temperature -10 C C working temperature -10 C C controlled by Forest Multi Remote and Forest Multi Wall Switch RF P2 program button control led OPEN/UP button STOP button CLOSE/DOWN button PROGRAMMING REMOTE / WALL CANCEL ONE CHANNEL OF DELETE ALL PREVIOUS PROGRAMMED SWITCH TO RECEIVER: REMOTE / WALL SWITCH REMOTES / WALL SWITCHES: press program button, led will blink press program button, led will blink press stop and close button of receiver for ~6 sec. press stop button press stop button led will blink and will go off hold the remote within 0,5 mtr from receiver. Select channel (1-15) and press OPEN button: select channel and press CLOSE button: led blinks 3 times and will go off led will blink and will go off

7 7 WIRING DIAGRAM FOREST FMS / TUBULAR MOTOR TO

8 8 TUBULAR MOTOR BUILD-IN RECEIVERAND ELECTRONIC LIMIT SETTING TECHNICAL SPECIFICATION: Nm, 33rpm, build-in receiver, electronic limit setting (110V) Nm, 28rpm, build-in receiver, mechanical limit setting (230V) Nm, 28rpm, build-in receiver, electronic limit setting (230V) Nm, 14rpm, build-in receiver, electronic limit setting (230V) Nm, 20rpm, build-in receiver, electronic limit setting,quiet (230V) max. running time 4 min. protection degree IP44 (230V), class B (110V) has to be used with Multi remote and/or Multi wall switch RF IMPORTANT 230V: use only wires BROWN (phase), BLUE (neutral) and GREEN/YELLOW (earth). The additional two wires (black and red) are for connecting the optional obstruction sensor. Make sure these two wires are not connected together and do NOT make contact with the power wires. 110V: use only wires BLACK (phase), WHITE (neutral) and GREEN (earth). 230Vac: PHASE L NEUTRAL EARTH brown blue yellow/green

9 9 TUBULAR MOTOR BUILD-IN MULTI RECEIVER AND ELECTRONIC LIMIT SETTING NOTE: during programming, keep the remote or wireless wall switch within 2 mtr from the receiver/motor PROGRAMMING REMOTE / WALL ADD MORE REMOTES / WALL SWITCHES / CANCEL ALL REMOTES OR SWITCH TO TUBULAR MOTOR: CHANNELS TO TUBULAR MOTOR WALL SWITCHES first select the desired channel first select the desired channel first select the programmed channel press button on motor, motor will 1st remote: press P2 button two times press P2 button one time turn short to acknowledge 2x P2 1 within 6 seconds: press P2 button two times 2nd remote: press P2 button one time press STOP button one time 2x P2 1x STOP 2 press OPEN-button one time motor will turn to acknowledge press P2 button one time 1x OPEN motor will turn to acknowledge motor will turn to acknowledge to add another channel on the same remote: 1.select the programmed channel, 2.press button P2 of remote two times, 3.select desired channel and press P2 button motor will turn to acknowledge CHANGING DIRECTION OF ROTATION To change the direction of rotation, keep green button on motor pressed for 7 sec, until motor turns to acknowledge.

10 10 TUBULAR MOTOR BUILD IN MULTI RECEIVER AND ELECTRONIC LIMIT SETTING ADJUSTING UPPER AND LOWER END LIMITS: IMPORTANT: - when more motors are programmed to one channel, end limits of all motors will be adjusted - during programming, keep the remote or wireless wall switch within 2 mtr from the receiver/motor press P2 button one time press OPEN button one time press P2 button one time 1x OPEN press STOP button when required motor will turn adjust to UPPER position height is reached. Press STOP button to acknowledge 5 times slowly for 1 seconds to confirm 5x STOP (slowly) press STOP button when required motor will turn adjust to LOWER limit height is reached. Press STOP button to acknowledge 5 times slowly for 1 seconds to confirm 5x STOP (slowly) motor will turn to acknowledge, limits have been set successfully.

11 11 TUBULAR MOTOR BUILD IN MULTI RECEIVER AND ELECTRONIC LIMIT SETTING CANCELLATION OF UPPER AND LOWER END LIMITS: IMPORTANT: When cancelling end limits, all motors programmed to that channel will be cancelled press P2 button one time press CLOSE button one time press P2 button one time motor will turn to acknowledge, limits has been set successfully. REVERSE DIRECTION SETTING: When motor is not running, press button on motor for ~ 7 seconds, until motor turns to acknowledge.

12 12 BS 24V DOUBLE SHAFT MOTOR BUILD-IN RECEIVER - ELECTRONIC LIMIT SETTING TECHNICAL SPECIFICATION: 24Vdc, 16Watt nom. 0.8Nm max. 1.0Nm 34 rpm max. running time 7 min. max. curtain weight 4 kg max. 5 cord rolls has to be used with Multi remote and/or Multi wall switch RF only to be used in Forest BS system and with Forest power supply for BS motor IMPORTANT: WHEN USING THE QUICK LOCK CORD ROLL, BE SURE TO LOCK THE CORD BEFORE USING THE MOTOR PROGRAMMING REMOTE REMOVE PROGRAMMED CHANNEL CHANGE MOTOR DIRECTION TO BS MOTOR: first select the desired channel first select the desired channel first select the desired channel switch on power to the motor: switch on power to the motor: switch on power to the motor: motor will jog to acknowledge: motor will jog to acknowledge: motor will jog to acknowledge: within 10 seconds after jog, within 10 seconds after jog, within 10 seconds after jog, press OPEN button on remote press STOP button on remote press CLOSE button on remote motor will jog to acknowledge: motor will jog to acknowledge: motor will jog to acknowledge: NOTE: if you need to start over, switch off the power and wait at least 20 seconds before switching in the power

13 13 BS 24V DOUBLE SHAFT MOTOR BUILD-IN RECEIVER - ELECTRONIC LIMIT SETTING SET UPPER END LIMIT SET LOWER END LIMIT DELETE LIMITS press P2 button once, press P2 button once, press P2 button twice, motor will jog to acknowledge: motor will jog to acknowledge: motor will jog to acknowledge: 1xP2 1xP2 2xP2 press OPEN button on remote, press CLOSE button on remote, press OPEN button on remote, motor will jog to acknowledge: motor will jog to acknowledge: motor will jog to acknowledge: 1x 1x 1x press P2 button once, motor will jog to acknowledge: 1xP2 press P2 button once, motor will jog to acknowledge: 1xP2 DELETE ALL MEMORY press P2 button twice motor will jog to acknowledge: 2xP2 adjust desired upper end limit and press P2 to save the upper limit: 1x P2 adjust desired lower end limit and press P2 to save the lower limit 1x P2 press CLOSE button on remote, motor will jog twice to acknowledge motor will jog to acknowledge: motor will jog to acknowledge: 1x

Battery Wall Controller. Manual

Battery Wall Controller. Manual Battery Wall Controller Manual 009303 Battery Wall Controller Manual Quick Start... 2 Product Description... 3 Installation Guidelines... 3 Behavior within the Z-Wave Network... 4 Operating the Device...

More information

CR9971 2 Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

CR9971 2 Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use ROBERTS Sound for Generations CR9971 2 Band Auto Set Dual Alarm Clock Radio Please read this manual before use Contents Contents... 1 Controls...2-5 Switching on... 6 Setting the time manually... 6 Setting

More information

HORNET Remote Control Systems

HORNET Remote Control Systems HORNET Remote Control Systems Up to 100metres Range 1 3 Button versions 12-30Vdc 0r 230Vac versions Reliable FM Technology Up to four 1000W Relay switches Waterproof Receiver (IP68) Momentary or Latching

More information

ZME_RC2 Z-Wave Remote Control

ZME_RC2 Z-Wave Remote Control ZME_RC2 Z-Wave Remote Control Firmware Version : 1.1 Quick Start S This device is a Z-Wave Remote Control with the logical function of a sensor. Push the "Include" button behind the slider on the back

More information

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8 ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8 Quick Start A This device is a Z-Wave Actuator. Triple click one of the buttons on the device will include the device.

More information

RF 1. Contents: Connecting diagram. Detailed information:

RF 1. Contents: Connecting diagram. Detailed information: Contents: Introduction UFH-ZONE-R UFH-EXTRAZONE -R Connection of a thermostat (UFH-THERM-R) o Joining of a thermostat with UFH-ZONE-R or UFH-EXTRAZONE-R Connection of a digital thermostat (UFH-THERM -RD)

More information

F O R E S T G R O U P.

F O R E S T G R O U P. just a gentle touch Remote control silent touch office automation Hotel automation Home automation forestgroup.com Product information The Forest Shuttle motorized system is available in three types, Shuttle

More information

ZME_WALLC-S Z-Wave Secure Wall Controller

ZME_WALLC-S Z-Wave Secure Wall Controller ZME_WALLC-S Z-Wave Secure Wall Controller Firmware Version : 1.0 Quick Start S This device operates as Z-Wave sensor in two modes: the normal control mode (daily use) or in management mode for setup. Pushing

More information

MAGICAR M871A. Car alarm with two-way remote User s guide

MAGICAR M871A. Car alarm with two-way remote User s guide MAGICAR M871A Car alarm with two-way remote User s guide EN MAGICAR M871A Car alarm with two-way remote User s guide TABLE OF CONTENTS Table of contents...2 1. Important notice...4 2. Introduction...4

More information

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System ELITE-L Series ELITE - Low Voltage / Dry contact Remote Control System Applications Garden Lighting Pond pumps Remote outdoor Switching Access control Industrial control Features 4 switched channels 1000W

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

PD 100A. Printing data system

PD 100A. Printing data system PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep

More information

Motion Activated Camera User Manual

Motion Activated Camera User Manual Brinno MAC200 User Manual Last Modified on 12/23/2015 7:51 pm EST Motion Activated Camera User Manual www.brinno.com Register@online http://www.brinno.com/support/register.html contact us: customerservice@brinno.com

More information

Stove Guard Kit User Manual

Stove Guard Kit User Manual Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent

More information

Chapter I Model801, Model802 Functions and Features

Chapter I Model801, Model802 Functions and Features Chapter I Model801, Model802 Functions and Features 1. Completely Compatible with the Seventh Generation Control System The eighth generation is developed based on the seventh. Compared with the seventh,

More information

INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200

INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200 INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200 FUSION CULTURE TABLE OF CONTENTS There s no point doing something if no one notices. We ve always believed the way to make things happen is by getting

More information

Installation Guide for Hive Active Heating

Installation Guide for Hive Active Heating Installation Guide for Hive Active Heating Important note: Installation should only ever be carried out by a qualified engineer. Technical Support If you need to contact Hive s Technical Support team during

More information

Application & Quick-Start Guide

Application & Quick-Start Guide Model: CRMWIC Web Intelligent Controller 1 This document will illustrate various ways to connect and use a CRM-WIC as well as programming examples. When connecting CRM-WIC, the installer has several interface

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

Alarm Security Kit - NVR

Alarm Security Kit - NVR Alarm Security Kit - NVR EN The alarm configuration menu (see above right screenshot) allows you to configure and change settings for the PIR movement sensors, window/door sensors, remote controls (key

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

DVB-T 730. User s Manual

DVB-T 730. User s Manual EPG Program Reservation There are 10 program timers to bring up reminder for a reserved program. 20 seconds before the start of the reserved program, a pop-up window will remind viewer. If no further instruction,

More information

SNIPER X1 VEHICLE SECURITY SYSTEM

SNIPER X1 VEHICLE SECURITY SYSTEM SNIPER X1 VEHICLE SECURITY SYSTEM Installation Manual Table of Contents 1. FEATURES & SPECIFICATIONS... 2 2. TRANSMITTER BUTTONS:... 2 3. FUNCTION... 2 3.1 Key Function:...2 3.2 Remote Transmitter Code

More information

PhoneWatch Smart Security System User Manual - Domonial

PhoneWatch Smart Security System User Manual - Domonial PW0002 10/13 Customer Support: 1850 753 753 PhoneWatch Ltd., Unit 3/4, Sandyford Park, Burton Hall Rd, Sandyford Industrial Estate, Dublin 18. Email: info@phonewatch.ie PhoneWatch Smart Security System

More information

Installation & Operations Manual

Installation & Operations Manual Installation & Operations Manual VoIP Command Center Made in the USA 3 Year Warranty N56 W24720 N. Corporate Circle Sussex, WI 53089 800-451-1460 262-246-4828 (fax) www.rathmicrotech.com www.area-of-refuge.com

More information

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply 1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,

More information

iloq P10S.10/20 Programming device User's Guide

iloq P10S.10/20 Programming device User's Guide iloq P10S.10/20 Programming device User's Guide CONTENTS CONTENTS... 2 GENERAL... 3 USING THE PROGRAMMING DEVICE... 5 Starting the programming device... 5 Programming of locks... 5 Programming of keys...

More information

EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit

EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit EDK 350 User Manual Important Notes This information describes the type of component and shall not be considered as assured characteristics. No

More information

GPS Vehicle and personal location tracker. User manual

GPS Vehicle and personal location tracker. User manual GPS Vehicle and personal location tracker User manual 1 Contents 1. Product overview... 2 2. Safety instruction... 3 3. Specification and parameters... 3 4. Getting started... 4 4.1 Hardware and accessories...

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage Description Supports DALI interface driver Programming Supports 0-10V Programmable Driver Programming Supports Other Controllers (TDD-ANPNx, SDD-AAPNx) Off-line programming capability Auto programming

More information

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page

More information

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

GSM AD05 Slave GSM Auto Dialer- Instruction Manual GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM

INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM Revised: August 28, 2014 PRODUCT REFERENCE MOUNTING ACCESSORIES PIR / MOTION DETECTION UNIT MAIN UNIT POWER ADAPTER MOUNTING ACCESSORIES

More information

AD425S Automatic door operator

AD425S Automatic door operator EC8666 Statement Automatic Door Operator is a reliable and quiet door opening and closing device. This product is ideal for enabling access to areas for people with disabilities or simply for convenience

More information

INSTALLATION MANUAL XM3 Reader

INSTALLATION MANUAL XM3 Reader INSTALLATION MANUAL XM3 Reader Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration

More information

TOMAHAWK CAR ALARMS. TW-9010 Two Way Car Alarm System

TOMAHAWK CAR ALARMS. TW-9010 Two Way Car Alarm System TOMAHAWK TW-9010 TOMAHAWK CAR ALARMS TW-9010 Two Way Car Alarm System USER MANUAL INSTRUCTIONS FOR INSTALLATION TOMAHAWK TW-9010 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27

More information

Quick start: Panic Watch EU

Quick start: Panic Watch EU Quick start: Panic Watch EU Technical specs Normal operating voltage Frequency range Wireless Range 1x CR2032 3V battery 868.42 MHz Min 150 meters in a mesh network Basic operations - The Panic Watch can

More information

Polyphase kwh Electricity Meter

Polyphase kwh Electricity Meter Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2

More information

CR9986 ROBERTS. Dual Alarm CD Clock Radio. Sound for Generations. Please read this manual before use

CR9986 ROBERTS. Dual Alarm CD Clock Radio. Sound for Generations. Please read this manual before use ROBERTS Sound for Generations CR9986 Dual Alarm CD Clock Radio Please read this manual before use Contents Contents... Controls... - Switching on and setting the time... 4 Listening to the radio... 5 Compact

More information

DAB1001. Wireless Digital Radio Interface. Installation & User Guide

DAB1001. Wireless Digital Radio Interface. Installation & User Guide DAB1001 Wireless Digital Radio Interface Installation & User Guide Contents Contents... 2 Introduction... 3 Contents of Package... 4 Installation... 5 Product Overview... 5 Installation Procedure... 5

More information

User manual BS1000 LAN base station

User manual BS1000 LAN base station 1/18 Contents 1.Introduction 2.Package of the LAN Base Station 3.Software installation 4.Installation of the Receiver 5.Sensor operation 6.Software operation Introduction The BS1000 is a receiver station

More information

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and

More information

User Manual of WT 493

User Manual of WT 493 User Manual of WT 493 Introduction Congratulations on your purchase of this smart unit. This unit can be used as a radio to catch the latest news and enjoy the beautiful music; it can also be used as an

More information

ROBERTS RC9907. Sound for Generations. 3 Band Radio Cassette Recorder. Please read this manual before use

ROBERTS RC9907. Sound for Generations. 3 Band Radio Cassette Recorder. Please read this manual before use ROBERTS Sound for Generations Mains ROBERTS RC 9907 3 Band Ra dio Cassette Re corder with Programmable Clock Alarm FM 88 94 96 100 104 106 108 MHz MW LW 540 600 800 100 0 12 00 160 0 khz 150 160 180 200

More information

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad) KCIENSBP KCIEN Heavy Duty Stainless Steel Illuminated Keypads Range: DIGICODE (Stand-Alone Keypad) INSTALLATION MANUAL Features: Input voltage: 12V to 24V AC or 12V to 48V DC Illuminated keys Heavy duty

More information

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4 RUST ELECTRONICS LTD Remote Switching Unit RCU-O4 MAINS REMOTE SWITCHING UNIT RCU-O4 The RCU-O4 is a radio remote controlled switching unit that will allow the remote operation of any appropriate electrical

More information

Your Digital Adapter Easy Setup Guide

Your Digital Adapter Easy Setup Guide Your Digital Adapter Easy Setup Guide Connect with the future of TV You re about to step up to a world of even better picture and sound, and this Easy Setup Guide is here to help every step of the way.

More information

Platinum App Software Guide

Platinum App Software Guide Platinum App Software Guide 1 Contents How to Download the Platinum App... 3 Equipment Requirements... 3 How the App Is Organized... 4 Setting Up Rooms and Shades... 5 Operating Your Window Coverings by

More information

Quick Guide. for Nikon 340.00 354.00 MHz, US FCC/IC 433.42 434.42 MHz, CE

Quick Guide. for Nikon 340.00 354.00 MHz, US FCC/IC 433.42 434.42 MHz, CE a MAKE IT POSSIBLE Quick Guide for Nikon 340.00 354.00 MHz, US FCC/IC 433.42 434.42 MHz, CE UPDATE FIRMWARE: Be sure ALL your PocketWizard ControlTL radios, including this one, are updated to the latest

More information

Point of view HDMI Smart TV dongle Mini RF Keyboard

Point of view HDMI Smart TV dongle Mini RF Keyboard Point of view HDMI Smart TV dongle Mini RF Keyboard English Contents Contents... 1 General notices for use... 2 Disclaimer... 2 Box Contents... 2 1. HDMI TV dongle... 3 1.1. Product display... 3 1.2. Instructions

More information

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET: SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the

More information

STATUS POWER MONITOR ALARM SOS DISARM

STATUS POWER MONITOR ALARM SOS DISARM STATUS POWER MONITOR ALARM SOS DISARM I. Features II. Preparation before use III. Host 1.LED status explanation 2. Host panel IV. System Settings 1. Coding of wireless sensors 2. Exit coding 3. Settings

More information

GUARD SENIOR. manual

GUARD SENIOR. manual GUARD SENIOR LISA manual Table of Contexts Basic description... 2 General Precautions... 2 SIM card install... 2 PC software install... 3 Running GUARD SENIOR LISA software...15 Configuration window...

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL

More information

COLOR VIDEO DOOR PHONE CDV-71BE/D

COLOR VIDEO DOOR PHONE CDV-71BE/D COLOR VIDEO DOOR PHONE CDV-71BE/D 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com Printed

More information

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004 Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical

More information

Wireless-N. User Guide. PCI Adapter WMP300N (EU) WIRELESS. Model No.

Wireless-N. User Guide. PCI Adapter WMP300N (EU) WIRELESS. Model No. 2,4 GHz WIRELESS Wireless-N PCI Adapter User Guide Model No. WMP300N (EU) Copyright and Trademarks Specifications are subject to change without notice. Linksys is a registered trademark or trademark of

More information

IN-OUT Thermometer with Cable Free Sensor and Clock

IN-OUT Thermometer with Cable Free Sensor and Clock IN-OUT Thermometer with Cable Free Sensor and Clock MODEL: RAR232 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RAR232 In-Out Thermometer with 433MHz cable free sensor and calendar

More information

GSM Smart Switch USER GUIDE

GSM Smart Switch USER GUIDE GSM Smart Switch USER GUIDE GSM Smart Switch allows switching almost any appliance ON and OFF remotely via mobile network. It is designed to receive start/stop commands from specially coded messages or

More information

1. Introduction... 3. 2.Fixture exterior view... 3. 3. Connecting the Robe Universal Interface... 4. 3.1 Software update of the fixture...

1. Introduction... 3. 2.Fixture exterior view... 3. 3. Connecting the Robe Universal Interface... 4. 3.1 Software update of the fixture... 1 Table of contests 1. Introduction... 3 2.Fixture exterior view... 3 3. Connecting the Robe Universal Interface... 4 3.1 Software update of the fixture... 4 3.2 Connecting a DMX console to the Media Fusion...

More information

ABOUT YOUR SATELLITE RECEIVER

ABOUT YOUR SATELLITE RECEIVER 2 Satellite Receiver ABOUT YOUR SATELLITE RECEIVER This chapter gives you an overview and a description of your satellite receiver. SATELLITE RECEIVER OVERVIEW SINGLE AND DUAL MODES REMOTE CONTROL SATELLITE

More information

Inwall 4 Input / 4 Output Module

Inwall 4 Input / 4 Output Module Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...

More information

DAB+ / FM Tuner Model: TU-201

DAB+ / FM Tuner Model: TU-201 DAB+ / FM Tuner Model: TU-201 Instruction Manual www.pulse-audio.co.uk 1 Safety Information The lightning bolt within a triangle is intended to alert the user to the presence of dangerous voltage levels

More information

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE Emergency Response System INSTALLATION & PROGRAMMING GUIDE Copyright micron 2005 Contents Product Description 3 Console Operation Overview 4 Console Wiring Diagram 5 User Manual 6 Transmitter Assembly

More information

Z-Wave.Me Wall Controller

Z-Wave.Me Wall Controller Z-Wave.Me Wall Controller ZME_06443: Wall Controller Firmware Version 1.1 1 General Information about Z- Wave Safe: Generally radio systems build a direct link between the transmitter and the receiver.

More information

Wireless Auto-dial Intruder Alarm System

Wireless Auto-dial Intruder Alarm System Wireless Auto-dial Intruder Alarm System User Manual User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Features and Function 1.

More information

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control Wireless Control Systems Accessories Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Accessories Programming Switching & Dimmer Functions

More information

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy

More information

MVS - Mini Video Speaker

MVS - Mini Video Speaker MVS - Mini Video Speaker Mini Clock Radio Night Vision Hidden Camera User Manual Spy Tec www.spytecinc.com GETTING STARTED Components Features Powering Up the Device Micro SD Memory Card for Data Storage

More information

Mini Timer Owner's Manual. Model MT13A

Mini Timer Owner's Manual. Model MT13A Mini Timer Owner's Manual Model MT13A Contents Introduction...3 Quick Tour...5 How to program a timed event...6 Special programming buttons...6 Setting up the Mini Timer...7 Setting the clock...7 Controlling

More information

Radio Thermostat Clock Part Number: 30800009. Installation & User Instructions. Suitable for all Ferroli Combination Boilers

Radio Thermostat Clock Part Number: 30800009. Installation & User Instructions. Suitable for all Ferroli Combination Boilers Radio Thermostat Clock Part Number: 30800009 Installation & User Instructions Suitable for all Ferroli Combination Boilers 2 Short Description Short description Radio Thermostat Clock - Transmitter The

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

SPY-BATT Battery Tutor Device Installation Manual Rev. 1.1-07/04/2016

SPY-BATT Battery Tutor Device Installation Manual Rev. 1.1-07/04/2016 SPY-BATT Battery Tutor Device Installation Manual Rev. 1.1-07/04/2016 1. GENERAL DESCRIPTION The SPY-BATT is a device that allows to monitor the state of your battery. The SPY-BATT stores over time the

More information

1.0. User s Guide & Manual USB 2.0 FLASH DRIVE

1.0. User s Guide & Manual USB 2.0 FLASH DRIVE 1.0 USB 2.0 FLASH DRIVE User s Guide & Manual Index Introduction 1 CHAPTER1 Features & Specifications 2 CHAPTER2 System Requirements 4 CHAPTER3 Getting Started Installation of the Windows 98SE Driver 5

More information

Universal control module for motorized devices

Universal control module for motorized devices Ref: MOD-0105-N The MOD-0105-N is a universal module for motorized devices, blinds, awnings, curtains, doors, etc.. Allows, with vivimat BUS, the local or remote control of a motorized devices, ensuring

More information

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition WWW.STELLAR.COM ST9000 SECURITY SYSTEM Button Function Condition 1 a. Arm and lock doors b. Car finder with sound c. Temporary stop alarm from sounding d. Remote lock doors 1 for 2 sec. Panic Anytime a.

More information

HAZUBA. HAZUBA AG Rainstrasse 17 4528 Zuchwil T 032 685 88 88 F 032 685 88 89 info@hazuba.ch 06/14

HAZUBA. HAZUBA AG Rainstrasse 17 4528 Zuchwil T 032 685 88 88 F 032 685 88 89 info@hazuba.ch 06/14 06/14 NEW BNC 002 BK 29.- CHF This Braun travel alarm clock measures 56mm x 56mm x 31mm and is available in two colours. It has an easy to read dial layout, crescendo alarm and a quiet German precision

More information

Fleets Vehicle GPS Tracker TS20 User Manual. (Version 1.0)

Fleets Vehicle GPS Tracker TS20 User Manual. (Version 1.0) Fleets Vehicle GPS Tracker TS20 User Manual (Version 1.0) Index Contents 1. Package Contents... 3 2. Features and Specifications... 3 3. Mechanical Size... 4 4. Knowledge before Usage... 4 4.1 Factory

More information

How To Program An Autodialer

How To Program An Autodialer GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT

More information

Blue Point Engineering

Blue Point Engineering lue Point Engineering 10-Ch udio Controller Description: This board is designed to control the sequence or random playback by remote user switch or relay contact of 1 to 10 channels of audio files that

More information

Introduction. Drenth Motorsport Gearboxes Fleuweweg 10 7468 AG Enter The Netherlands Phone: +31 (0)547 38 26 96 Fax: +31 (0)547 38 20 65

Introduction. Drenth Motorsport Gearboxes Fleuweweg 10 7468 AG Enter The Netherlands Phone: +31 (0)547 38 26 96 Fax: +31 (0)547 38 20 65 25.03.0023 Introduction The display comes with a software application. With the software application information shown on the display can be adjusted. There are different modes to adjust: the shape of

More information

WITURA CORPORATION SDN BHD

WITURA CORPORATION SDN BHD WT 1010SA Stand Alone GSM Alarm System User Manual and Installation Instructions Version: 1.2 Updated: 4 JAN 2012 WITURA CORPORATION SDN BHD Stand Alone GSM Alarm System Instruction Manual 1 Introduction:

More information

Navigator. Welcome 1 pg.3. Router Setup 2 pg.5. Send Expedition Data to Ventus Navigator 3 pg.6. Using Ventus Navigator 4 pg.8

Navigator. Welcome 1 pg.3. Router Setup 2 pg.5. Send Expedition Data to Ventus Navigator 3 pg.6. Using Ventus Navigator 4 pg.8 Navigator www.ventusnavigation.com Welcome 1 pg.3 Router Setup 2 pg.5 Send Expedition Data to Ventus Navigator 3 pg.6 Number of Network Connections... 3-1 pg.6 Configure Network Connection.. 3-1 pg.6 Select

More information

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved.

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved. Sensi TM Wi-Fi Programmable Thermostat MANUAL OPERATION Version: March 2016 2016 Emerson Electric Co. All rights reserved. Contents MANUAL OPERATION GUIDE Buttons and Icons 3 Basic Functionality 4 Manual

More information

Part 2. Copyright 1998 Philips Consumer Communications L.P. All rights reserved. Printed in Mexico. Issue 1AT&T 848229506

Part 2. Copyright 1998 Philips Consumer Communications L.P. All rights reserved. Printed in Mexico. Issue 1AT&T 848229506 2 User's Manual for Two-Line Digital Answering System Telephone with Speakerphone 1872 Fold open this paper for information about this telephone's installation and operation. Please read Part 1 Important

More information

TIME BOX BIOMETRIC TECHNICAL INSTRUCTIONS AND QUICK START GUIDE IT IS RECOMMENDED TO READ THIS MANUAL BEFORE OPERATING THE SYSTEM

TIME BOX BIOMETRIC TECHNICAL INSTRUCTIONS AND QUICK START GUIDE IT IS RECOMMENDED TO READ THIS MANUAL BEFORE OPERATING THE SYSTEM TIME BOX BIOMETRIC TECHNICAL INSTRUCTIONS AND QUICK START GUIDE IT IS RECOMMENDED TO READ THIS MANUAL BEFORE OPERATING THE SYSTEM BODET Software B.P. 402 Boulevard du Cormier F-49302 CHOLET Cedex www.bodet.com

More information

1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target 4-2 ABNORMAL OPERATI 4-2-1 An is represented by 3 digit characters. The first 2 digit means the subsection, and the last 1 digit means the specifics. Ex.) Indoor unit Network communication Error Subsection

More information

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness WIRING HARNESS FOR AS635P4 ANTENNA NOT USED 5 PIN WHITE PLUG 2 PIN WHITE PLUG GREEN - PARKING BRAKE INPUT (-) BLUE - NOT USED 3 PIN BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

More information

GSM ALARM SYSTEM GCM 8

GSM ALARM SYSTEM GCM 8 GSM ALARM SYSTEM GCM 8 GCM8 is a universal alarm system. It can be used as alarm system in vehicles, apartments, houses etc. Also GCM8 can be used for opening garage doors. GCM8 is designed to work with

More information

T-100-R Installation Guide

T-100-R Installation Guide T-100-R Installation Guide Table of Contents Page 2 Overview T-100-R Z-Wave Thermostat 3-4 Installation HVAC System Setup 6 Installer Settings Menu Items 7-9 Installer Settings Summary 10-11 Wiring Standard

More information

e-ask electronic Access Security Keyless-entry

e-ask electronic Access Security Keyless-entry e-ask electronic Access Security Keyless-entry e-fob Keyless-entry entry System Full-Function Function Installation Manual FCC ID: TV2EFOB1 (UM20 ~ 22793-02) Table of Contents Introduction... 1 e-fob Operation

More information

Energy Communication Unit (ECU)

Energy Communication Unit (ECU) Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.7) Version:3.0 ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2

More information

evohome Wireless Radiator Zoning Kit Installation & User Guide

evohome Wireless Radiator Zoning Kit Installation & User Guide evohome Wireless Radiator Zoning Kit Installation & User Guide Getting the most from your evohome system Installation & User Guide 1 Getting the most from your evohome system Thanks for choosing an evohome

More information

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue

More information