Overview of Safety Standards
|
|
- Cory Strickland
- 7 years ago
- Views:
Transcription
1 Overview of Safety Standards New Machinery Directive 2006/42/EG 2010 Europe AG
2 Machine Safety 2 EU Standards for Machine and Device Manufacturers Machinery Directive 2006/42/EG Low Voltage Directive 2006/95/EG EMC Directive 2004/108/EG Functional safety IEC/EN EN ISO /2 IEC/EN Electrical safety EN EN EN Electromagnetic compatibility: - Radiation - Immunity - Conducted interference EN Series EN 550xx Series EN Depending on the product, additional harmonized standards may apply.
3 European Machinery Directive 3 MRL 2006/42/EG European Directive: Not legally binding (06/29/2006) All EU member states were required to incorporate the Machinery Directive into national law. (The deadline was 12/29/2009.) Example: In Germany, the Directive was implemented by the Equipment and Product Safety Law (GPSG, 9th edict). GPSG, Machinery Directive German National Law: In effect since 12/29/2009 Note: There was no transition period! - Product liability - Conformity assessment - Technical safety requirements - Documentation requirements - EC Declaration of Conformity (Machinery Directive)
4 When Is a Manufacturer Allowed to Affix a CE Marking on a Product? 4 Product requirements: Technical documents Technical construction file (TCF) Technical documentation for a product providing evidence of conformity with regard to the following points: Product name and description Construction and detail drawings Product description with explanation of specific purpose List of standards and technical specifications applied Documents on risk assessment and measures for preventing risk Technical reports detailing the results of tests conducted by the manufacturer or by an authorized testing agency Operating instructions EC Declaration of Conformity
5 Machine Safety: Overview 5 Machine construction and risk evaluation EN ISO EN ISO Basic terms, general principles Risk assessment Functional and safety requirements for the safety-related functions Design and implementation of safety-related functions IEC/EN 62061:2005 Safety of machines Functional safety of safety-related electrical, electronic, and programmable electronic control systems EN ISO :2006 Safety of machines Safety-related parts of programmable electronic control systems and all types of machinery, regardless of the technology or energy type employed (electric, hydraulic, pneumatic, mechanical, etc.) Electrical safety aspects EN Safety of machines, electrical equipment of machines
6 Safety Goals Relating to Design: Risk Assessment (ISO 14121) 6 Start Iterative process Risk assessment Define machine limits Identify hazards Estimate risk Evaluate risk Was the risk adequately reduced? Yes Risk analysis Application limits = household, industry Spatial limits = interfaces, energy supply Time limits = estimated product durability What are the risks that must be dealt with? How serious are these risks? Do measures need to be taken to deal with these risks? End No Take measures to minimize risks in accordance with DIN EN ISO 12100
7 Risk Minimization (ISO 12100) Measures taken to minimize risks in accordance with DIN EN ISO OK 7 EXAMPLE: Punching tool No Intrinsically safe design Protective equipment (SRP/CS) User information Does the selected safety measure depend on a control system? (SRP/CS) Yes e.g.: Modifying product shape e.g.: Protective covers Safety beam sensors Safety-related functions e.g.: User s manual Design of the control system s safety-related parts in accordance with DIN EN ISO Residual risk; will new risks emerge? SRP/CS = safety-related parts of the control system
8 Risk and Hazard Assessment 8 EN ISO Mechanical hazards Electrical hazards Heat-related hazards Hitting Crushing Clipping Cutting Puncture EN ISO Risk minimization Material- and substancerelated hazards Noise hazards Risk reduction through protective equipment Risk reduction through intrinsically safe design Radiation hazards Vibration-related hazards Ergonomics-related hazards DIN EN ISO Safety-related parts of control systems (SRP/CS): functional safety
9 Risk Minimization According to DIN EN ISO Design process for safety-related parts of a control system (SCP/CS) in accordance with ISO 13849: 1. Determine required performance level (PL r) 2. Choose category 3. Determine components used 4. Perform evaluation / consider diagnostic coverage (DC) 5. Perform evaluation / consider control system s robustness (CCF) 6. Verify PL for safety-related functions PL Pl r 7. Validation: Have all requirements been met?
10 Determining the Required Machine Performance Level (PL r ) 10 Risk graph F1 P1 PL r a Low risk Severity of injury (S) S1: Slight (usually reversible) injury S1 P2 P1 b S2: Heavy (usually irreversible) injury, including death F2 P2 P1 c Frequency and/or duration of stay (exposure to hazard) (F) F1: Seldom to infrequent, and/or short exposure to hazard S2 F1 F2 P2 P1 d F2: Frequent to continuous, and/or long exposure to hazard Feasibility of preventing harm or limiting damage (P) P2 Machine must meet PL d requirement e High risk P1: Possible under certain conditions P2: Hardly possible
11 Achieving the Required Performance Level (PL) 11 The performance level (for SRP/CS design) is a measure of several factors that determine the system s safety and reliability. The PL principle measures 4 auxiliary quantities: Designated architecture (category) Hardware quality (MTTF d ) Mean time to dangerous failure Diagnostic coverage (DC) Common cause failure (CCF) Performance level
12 Risk Assessment, Categories, Bar Graph 12 Relationship between category, MTTF d, DC, and CCF Low Medium High Without CCF With CCF At least 65 points MTTF d Performance level a 10-5 to < 10-4 [h -1 ] Performance level b 3*10-6 to < 10-5 [h -1 ] Performance level c 10-6 to < 3*10-6 [h -1 ] Performance level d 10-7 to < 10-6 [h -1 ] Performance level e 10-8 to < 10-7 [h -1 ] PFH D values DC Cat. B Cat. 1 Cat. 2 Cat. 2 Cat. 3 Cat. 3 Cat. 4 none none low medium low medium high
13 Category B and Category 1 13 I L O I = Input unit L = Logic O = Output unit Category Requirement (summary) System performance MTTF d DC avg CCF The safety related parts of control systems Fault occurrence can Low None Not and/or their protective equipment, as well lead to failure of the to relevant as their components, must be designed, built, selected, combined, and mounted in safety related function. medium B compliance with the relevant standards, and be capable of withstanding the expected strain. Fundamental safety principles must be applied. 1 The requirements for category B must be fulfilled. Well proven components and well tested safety principles must be applied. Fault occurrence can lead to failure of the safety related function; however, the probability of fault occurrence is lower than in category B. High None Not relevant Safety principle for these categories: Main determinant: choice of components
14 Category 2 14 I L O m TE = Testing device OTE = TE output m = Monitoring TE OTE Dotted lines = feasible fault detection Category Requirement (summary) System performance MTTF d DC avg CCF 2 The requirements for category B must be met, and Fault occurrence can lead well proven safety principles must be applied. to failure of the The safety related function must be tested at suitable safety related function intervals by the machine s control system; the between tests. mandatory monitoring points include machine startup The test will detect any and the start of any high risk step in the production such failure. process (e.g., start of a new cycle, start of a different motion type). Low to high Low to medium Must be monitored Safety principle for this category: Main determinant: system architecture Testing device; monitoring
15 Category 3 15 I1 L1 O1 c I2 L2 O2 m c = Cross-validation m = Monitoring Dotted lines = feasible fault detection Category Requirement (summary) System performance MTTF d DC avg CCF The requirements for category B must be met, and If a single fault occurs, the Low Low Must well proven safety principles must be applied. Safetyrelated safety related function to to be parts must be designed always high medium monitored in such a way that: remains intact a single fault in any of these parts will not lead to Some but not all faults loss of the safety related function, and will be detected. 2. if detection is feasible, the individual fault will be detected. An accumulation of unknown faults can lead to failure of the safety related function. Safety principle for this category: Main determinant: architecture Dual channel / redundancy
16 Category 4 I1 L1 O1 c I2 L2 O2 m c = Cross-validation m = Monitoring Lines = feasible fault detection 16 Category Requirement (summary) System performance MTTF d DC avg CCF The requirements for category B must be met, and well proven safety principles must be If a single fault occurs, the safety related function High High Must be monitored applied. Safety related parts must be designed in such a way that: 1. a single fault in any of these parts will not always remains intact. If fault accumulation is detected, the safetyrelated function will be less lead to loss of the safety related function, and 4 2. the individual fault will be detected on or before the next occasion on which the safetyrelated function is in demand. If this is not possible, an accumulation of faults must not lead to failure of the safety related function. likely to fail (high diagnostic coverage). Safety principle for this category: Main determinant: architecture Dual channel / redundancy
17 MTTF d Component Quality 17 Definition: The MTTF d value specifies the mean time to dangerous failure for every channel This is a statistical value; it does not represent a guarantee of product durability. The MTTF d value is divided into 3 categories: MTTF d category for every channel Low Medium High MTTF d range for every channel 3 to 10 years 10 to 30 years 30 to 100 years The PFH D value is almost the equivalent: it specifies the probablility of a dangerous failure per hour i.e., the inverse of MTTF d NOTE: A value >100 years would not be a desirable means of reaching a better PL; rather, the emphasis should be placed on improving the designated architecture. This value is specified by the component manufacturer.
18 DC Diagnostic Coverage 18 Definition: The diagnostic coverage value specifies the ratio of dangerous failures detected to the total number of dangerous failures. DC = Dangerous failures detected Total number of dangerous failures The DC value is divided into 4 categories: DC category DC range None < 60% Low 60% to < 90% Medium 90% to < 99% High 99% and more Diagnostic measures for determining DC values from Standard , Annex E.1 For additional measures, please refer to IEC , Tables A.2 to A.15.
19 Diagnostic Coverage: Sample Safety Measures 19 Excerpt from EN ISO , Table E.1: Safety measure Cyclical test impulse generated by a dynamic modification of input signals Plausbility test, e.g., use of 1c and breaker contacts belonging to forcibly guided relays Cross validation of input signals without dynamic testing Cross validation of input signals with dynamic testing if short circuits cannot be detected (used for multiple inputs/outputs) Cross validation of input signals with immediate and intermediate results in the logic (L), as well as time and logic related program run monitoring and detection of static failures and short circuits (used for multiple inputs/outputs) Indirect monitoring (e.g., monitoring via pressure tanks; electrical position monitoring of control elements) Direct monitoring (e.g., electrical position monitoring of control valves, monitoring of electromechanical units through forced operation) Fault detection by the process Monitoring of certain sensor characteristics (response time, analog signal area, e.g., electrical resistance, capacitance) DC 90% 99% 0% to 99%, depending on how often a signal is modified by the application 90% 99% 90% to 99%, depending on the application 99% 0% to 99%, depending on the application. Used alone, this measure is not sufficient to meet performance level e criteria! 60%
20 CCF: Common Cause Failure 20 Definition: Failure of several different units resulting from a single event, where these failures are not consequences of each other Measures to prevent CCF are required for Categories 2, 3, and 4. Table with measures to prevent CCF: Standard , Annex F.1 A total of at least 65 points is required! EXAMPLE: Because of overheating, two sensors malfunction independently of each other.
21 Measures to Prevent CCF 21 No. Measures to prevent CCF Points 1 Separation / disconnection Physical separation between signal paths 15 2 Diversity Various different technologies are used (programmable electronic systems and hardwiring) 20 3 Design / application / experience Protection against overvoltage, positive pressure, overcurrent 15 Use of well tested components 5 4 Evaluation / analysis Have the results of an FMEA been taken into account? 5 5 Competence / education CCF training for developers and technicians 5 6 Environment Protection against contamination; electromagnetic compatibility 25 Other influences (temperature, shock, vibration) 10 A total of at least 65 points is required! Maximum number of points 100
22 Risk Assessment, Categories, Bar Graph 22 Relationship between category, MTTF d, DC, and CCF Low Medium High Without CCF With CCF At least 65 points MTTF d Performance level a 10-5 to < 10-4 [h -1 ] Performance level b 3*10-6 to < 10-5 [h -1 ] Performance level c 10-6 to < 3*10-6 [h -1 ] Performance level d 10-7 to < 10-6 [h -1 ] Performance level e 10-8 to < 10-7 [h -1 ] PFH D values DC Cat. B Cat. 1 Cat. 2 Cat. 2 Cat. 3 Cat. 3 Cat. 4 none none low medium low medium high
23 Safety-Related Functions: Examples (1) 23 Emergency stop button, emergency pull cord, or safety door opener When any of these safety-related functions is triggered, a stop signal is transmitted via safety relay. This signal shuts down the system. The subsequent reset signal must not trigger a machine restart. Laser scanner and safety light curtain If the area monitored by the laser scanner is penetrated, or if the safety light curtain is disturbed, the hazardous part of the machine must be shut down.
24 Calculating the PL for a Safety-Related Function: 2 Methods 24 Method 1: Detection (Input) Processing (Logic) Reaction (Output) Block method: Required for the exact calculation Safety-related function Considers the entire SRP/CS Most appropriate for complex, interconnected SRP/CS Method 2: Subsystem method Simplified form for determining the PL by means of combination tables IfthePFH D of the subsystems is a known value, the PL can be estimated quickly. ThePFH D value is specified by the manufacturer
25 Total Performance Level (Method 1: Block Calculation) 25 Impact of the PFH D value on the total performance level Detection (Input) Processing (Logic) Reaction (Output) Case #1 PLe PFH D = 2.2 x 10-9 PLe PFH D = 8.7 x 10-9 PLe PFH D = 2.1 x 10-9 PFH D total = 2.2 x x x 10-9 = 13 x 10-9 = 1.3 x 10-8 = PLe Case #2 PLe PFH D = 2.2 x 10-8 PLe PFH D = 6.78 x 10-8 PLe PFH D = 2.2 x 10-8 PFH D total = 2.2 x x x 10-8 = x 10-8 = 1.12 x 10-7 = PLd PLe = > 10-8 to < 10-7 (SIL3)
26 Determining the PL for a Series Connection (Method 2: Table Lookup) 26 Subsystem method This procedure is used to determine the PL of the entire combined SRP/CS that execute the safety-related function. Pl low N low PL Steps: 1. Determine the lowest PL; this is PL low 2. Determine the numberl N low N of the SRP/CS, with Pl i = PL low 3. Look up the PL in the table PLe + PLe + PLe PLe a b c d e > 3 Not possible 3 a > 2 a 2 b > 2 b 2 c > 3 c 3 d > 3 d 3 e
27 DIN EN ISO /2 & IEC/EN DIN EN ISO Applies to safety-related parts of programmable electronic control systems and all types of machinery, regardless of the technology or energy type employed (electric, hydraulic, pneumatic, mechanical, etc.) versus IEC/EN Applies to safety-related electric, electronic, and programmable electronic control systems (SRECS) for machines
28 Comparison Between PL and SIL 28 PL and SIL can be mapped onto each other via the PFH D value. Performance level ISO PL Probability of dangerous failures per hour (1/h) PFH D Safety integrity level IEC SIL a 10-5 to < 10-4 Not defined b 3*10-6 to < c 10-6 to < 3* d 10-7 to < 10-6 e 10-8 to <
29 Thank You! Panasonic Your Automation Partner
Hydraulic/pneumatic drive Cylinder (machine actuator) Optoelectronics Light curtain (sensor) Electronics Control system Danger! Hydraulics/pneumatics Valves (actuators) Safety control SRP/CS subsystem
More informationPABIAC Safety-related Control Systems Workshop
Health and and Safety Executive PABIAC Safety-related Control Systems Workshop KEY STANDARDS FOR ELECTRICAL & FUNCTIONAL SAFETY OF PAPERMAKING MACHINES: APPLICATION & USE Steve Frost HM Principal Electrical
More informationMachineontwerp volgens IEC 62061
Machineontwerp volgens IEC 62061 Insert Photo Here Safety solution Architect Safety Local Business Leader Benelux. Stephen Podevyn Safety Solution Seminar Agenda deel 1 1. Richtlijnen en normen 2. Safety
More informationPresentation Safety Legislation and Standards
levels in different discrete levels corresponding for each one to a probability of dangerous failure per hour: > > The table below gives the relationship between the perforance level (PL) and the Safety
More informationContactor Monitoring Relay CMD Cost-Effective Solution for Safe Machines
www.eaton.com/moellerproducts Contactor Monitoring Relay CMD Cost-Effective Solution for Safe Machines Technical Paper Dipl.-Ing. Wolfgang Nitschky The way to safe machines During the engineering design
More informationHow to design safe machine control systems a guideline to EN ISO 13849-1
How to design safe machine control systems a guideline to EN ISO 13849-1 SP Technical Research Institute of Sweden Johan Hedberg Andreas Söderberg Jan Tegehall SP Electronics SP REPORT 2011:81 How to design
More informationSafety and functional safety A general guide
Safety and functional safety A general guide This document is an informative aid only. The information and examples given are for general use only. They do not describe all the necessary details for implementing
More informationSISTEMA - Sicherheit von Steuerungen an Maschinen
Author: Günter Hog, Parker Hannifin GmbH Dangerous point/machine: File name: L:\PUBLIC\EE\Sicherheitstechnik\Baumusterpruefbescheinigung\Compax 3 Sistema Library\in Vorbereitung\EN\Parker Compax3S STO
More informationSAFETY MANUAL SIL Switch Amplifier
PROCESS AUTOMATION SAFETY MANUAL SIL Switch Amplifier KCD2-SR-(Ex)*(.LB)(.SP), HiC282* ISO9001 2 With regard to the supply of products, the current issue of the following document is applicable: The General
More informationIntroduction to Safety
Introduction to Safety 1- Foreword Purpose of this section is to provide the machine manufacturer with a quick introduction on some standards related to machine safety, to clarify some basic principles
More informationOriginal instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationApplication Technique. Safety Function: Magnetic Door Switch Monitoring
Application Technique Safety Function: Magnetic Door Switch Monitoring Products: MC1 Magnetically-coded Door Switch, Guardmaster Dual-input Safety Relay Safety Rating: CAT. 3, PLd to EN ISO 13849-1: 2008
More informationCONFIGURABLE SAFETY RELAYS
MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional
More informationSafe Machinery Handbook
Safe Machinery Handbook 2 Contents Introduction...4 Why safety?...6 Legal framework...10 Risk assessment...16 Safe design and safeguarding...22 Functional Safety...30 Control system standards including
More informationThe SISTEMA Cookbook 4
The SISTEMA Cookbook 4 When the designated architectures don t match Version 1.0 (EN) Authors: Michael Hauke, Ralf Apfeld Institut für Arbeitsschutz der Deutschen Gesetzlichen Unfallversicherung (IFA)
More informationStandards which are relevant to the selection and use of electrical switches for safety related controls in mine shaft and winding systems HSL/2007/58
Harpur Hill, Buxton Derbyshire, SK17 9JN T: +44 (0)1298 218000 F: +44 (0)1298 218590 W: www.hsl.gov.uk Standards which are relevant to the selection and use of electrical switches for safety related controls
More informationRisk Assessment in Accordance with EN ISO 14121-1 and EN ISO 12100:2010
Risk Assessment in Accordance with EN ISO 14121-1 and EN ISO 12100:2010 Introduction Safety Integrated siemens.com/safety-integrated Contents 1 General 3 1.1 Warranty and Liability 3 1.2 Description of
More informationSafety Manual BT50(T) Safety relay / Expansion relay
Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document
More informationSAFETY MANUAL SIL SMART Transmitter Power Supply
PROCESS AUTOMATION SAFETY MANUAL SIL SMART Transmitter Power Supply KFD2-STC4-(Ex)*, KFD2-STV4-(Ex)*, KFD2-CR4-(Ex)* ISO9001 2 3 With regard to the supply of products, the current issue of the following
More informationVersion: 1.0 Latest Edition: 2006-08-24. Guideline
Management of Comments on this report are gratefully received by Johan Hedberg at SP Swedish National Testing and Research Institute mailto:johan.hedberg@sp.se Quoting of this report is allowed but please
More informationTina 2A/B Adaptor unit
Original instructions Tina 2A/B Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
More informationSafe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives
User Manual Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives Catalog Number 20A-DG01 Topic Page General Description 2 What Is the DriveGuard Safe Torque Off
More informationSAFETY MANUAL SIL RELAY MODULE
PROCESS AUTOMATION SAFETY MANUAL SIL RELAY MODULE KFD0-RSH-1.4S.PS2 ISO9001 3 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery
More informationSAFETY MANUAL SIL SWITCH AMPLIFIER
PROCESS AUTOMATION SAFETY MANUAL SIL SWITCH AMPLIFIER KF**-SR2-(Ex)*(.LB), KFD2-SR2-(Ex)2.2S ISO9001 2 With regard to the supply of products, the current issue of the following document is applicable:
More informationSafe Machinery Handbook
Safe Machinery Handbook Contents Introduction...4 Why safety?...6 Legal framework...10 Risk assessment... 16 Safe design and safeguarding...22 Functional Safety... 30 Control system standards including
More informationSafety Requirements Specification Guideline
Safety Requirements Specification Comments on this report are gratefully received by Johan Hedberg at SP Swedish National Testing and Research Institute mailto:johan.hedberg@sp.se -1- Summary Safety Requirement
More informationHardware safety integrity Guideline
Hardware safety integrity Comments on this report are gratefully received by Johan Hedberg at SP Swedish National Testing and Research Institute mailto:johan.hedberg@sp.se Quoting of this report is allowed
More informationCONFIGURABLE SAFETY RELAYS
MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationSafety Relays ESM/ESM-F
Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in
More informationCE Marking and Technical Standardisation
GAMBICA Technical Guide CE Marking and Technical Standardisation Guidelines for application to Electrical Power Drive Systems Edition 4 : 2015 CE Marking and Technical Standardisation Guidelines for application
More informationSafety Function: Door Monitoring
Application Technique Safety Function: Door Monitoring Products: Trojan 5 Switch, GuardLogix Controller Safety Rating: CAT. 3, PLd to ISO 13849-1: 2008 Topic Page Important User Information 2 General Safety
More informationFunktionale Sicherheit IEC 61508 & IEC 62443
Funktionale Sicherheit IEC 61508 & IEC 62443 Seite 1 PROFIsafe trifft New York PROFIsafe Senior Safety Expert Siemens AG, DF FA AS E&C-PRM3 bernard.mysliwiec@siemens.com Seite 2 Roosevelt Island Picture
More informationSAFETY ENGINEERING SOFTWARE
SAFETY ENGINEERING SOFTWARE The Project Manager structures and manages complex projects, enables the project team to use centrally administered data, and with job-related checklists, ensures that nothing
More informationMachinery Safety. Presented by Paul Laidler. TÜV SÜD Product Service
Machinery Safety Presented by Paul Laidler Machinery Division Safety Solutions Assistance in meeting the requirements of machinery safety legislation Machinery, Low Voltage and Electro Magnetic Compatibility
More informationSafety PLC for rolling stock Safety Controller Pluto Harsh Environment
Safety PLC for rolling stock Safety Controller Pluto Harsh Environment Safety PLC for rolling stock More reliability and safety The requirements for rail vehicles of today and tomorrow grow constantly.
More informationTRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,
More informationSquare D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
More informationINTERNATIONAL REGULATIONS FOR SAFETY OF LASER PRODUCTS AND OF LASER PROCESSING MACHINES - AN OVERVIEW -
Paper: # INTERNATIONAL REGULATIONS FOR SAFETY OF LASER PRODUCTS AND OF LASER PROCESSING MACHINES - AN OVERVIEW - Associazione Industriali Vicenza, 18.03.10 Dipl.-Ing. Thomas Püster - Safety engineer -
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationSelecting Sensors for Safety Instrumented Systems per IEC 61511 (ISA 84.00.01 2004)
Selecting Sensors for Safety Instrumented Systems per IEC 61511 (ISA 84.00.01 2004) Dale Perry Worldwide Pressure Marketing Manager Emerson Process Management Rosemount Division Chanhassen, MN 55317 USA
More informationELECTROTECHNIQUE IEC INTERNATIONALE 61508-3 INTERNATIONAL ELECTROTECHNICAL
61508-3 ª IEC: 1997 1 Version 12.0 05/12/97 COMMISSION CEI ELECTROTECHNIQUE IEC INTERNATIONALE 61508-3 INTERNATIONAL ELECTROTECHNICAL COMMISSION Functional safety of electrical/electronic/ programmable
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationFailure Modes, Effects and Diagnostic Analysis
Failure Modes, Effects and Diagnostic Analysis Project: Plant-STOP 9475 Company: R. STAHL Schaltgeräte GmbH Waldenburg Germany Contract No.: STAHL 13/04-027 Report No.: STAHL 13/04-027 R024 Version V1,
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationCompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
More informationSIL manual. Structure. Structure
With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central
More informationInstallation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
More informationRisk Assessment as the principal element of the CE Conformity Assessment of Wind Turbines
Product liability claims caused by an incomplete risk assessment can be avoided! Risk Assessment as the principal element of the CE Conformity Assessment of Wind Turbines Holger Berndt, Germanischer Lloyd
More informationABB industrial drives. Application guide ACS800-01/U1/04/04LC/04M/U4/11/U11/14/31/U31/104/104LC Safe torque off function (+Q967)
ABB industrial drives Application guide ACS800-01/U1/04/04LC/04M/U4/11/U11/14/31/U31/104/104LC Safe torque off function (+Q967) List of related manuals Single drive and drive modules hardware manuals ACS800-01/U1
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationIEC 61508 Overview Report
IEC 61508 Overview Report A Summary of the IEC 61508 Standard for Functional Safety of Electrical/Electronic/Programmable Electronic Safety-Related Systems exida Sellersville, PA 18960, USA +1-215-453-1720
More informationDLP-PU/E Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
More informationaseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
More informationApplication Technique. Safety Function: Door Monitoring
Application Technique Safety Function: Door Monitoring Products: Trojan 5 Interlock Switch, GuardLogix Controller, PowerFlex 525 Drive with Safe Torque-off Safety Rating: CAT. 3, PLd to EN ISO 13849-1:
More informationNo. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1
No. : EX##-OMF0004 OPERATION MANUAL EX12#-SMB1 Contents 1. Safety instructions ------------------------------------------------------ P3 2. Notes ------------------------------------------------------
More informationFunctional safety. Essential to overall safety
Functional safety Essential to overall safety What is Functional safety? In public spaces, factories, offi ces or homes; we are surrounded by an increasing number of electric and electronic devices and
More informationCQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
More informationPNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
More informationArc Terminator Active Arc-Resistant Switchgear
Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationArc Flash Avoidance and its Application to Overhead Traveling Cranes
Arc Flash Avoidance and its Application to Overhead Traveling Cranes Whitepaper August 2012 Jason Wellnitz, Controls Product Manager Material Handling Numerous technical papers, bulletins, magazine articles
More informationAnalog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
More informationUnderstanding Safety Integrity Levels (SIL) and its Effects for Field Instruments
Understanding Safety Integrity Levels (SIL) and its Effects for Field Instruments Introduction The Industrial process industry is experiencing a dynamic growth in Functional Process Safety applications.
More informationInsulation resistance
The insulation resistance is particularly important for the prevention of damage and injury, and for the reliability of electrical systems and equipment. On the one hand it is basis for the protection
More informationVersion: 1.0 Last Edited: 2005-10-27. Guideline
Process hazard and risk Comments on this report are gratefully received by Johan Hedberg at SP Swedish National Testing and Research Institute mailto:johan.hedberg@sp.se -1- Summary This report will try
More informationA holistic approach to Automation Safety
A holistic approach to Automation Safety Mark Eitzman - Manager, Safety Business Development How technology, global standards and open systems help increase productivity and overall equipment effectiveness.
More informationRISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationSYSTEM DESCRIPTION Termination Boards
PROCESS AUTOMATION SYSTEM DESCRIPTION Termination Boards Non-IS Termination Boards for Yokogawa CENTUM C3 and ProSafe RS ISO9001 With regard to the supply of products, the current issue of the following
More informationIEC 61508 Functional Safety Assessment. ASCO Numatics Scherpenzeel, The Netherlands
IEC 61508 Functional Safety Assessment Project: Series 327 Solenoid Valves Customer: ASCO Numatics Scherpenzeel, The Netherlands Contract No.: Q09/04-59 Report No.: ASC 09-04-59 R003 V1 R3 61508 Assessment
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationTechnical Description. Transistor D.C. Chopper Controller Type GS 24 S
Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine
More informationSF06. Machine Safety Solutions Overview
SF06 Machine Safety Solutions Overview Welcome During this session we will discuss various types of safety devices available for machinery safety solutions to prevent access to or control a hazard. We
More informationMagnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationE-STOP relays, safety gate monitors
Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationAnalog Servo Drive 25A8
Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit
More informationChrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
More informationSMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
More informationInstruction book IQAN-MDM. Publ. no. HY17-8328/UK Edition June, 2007
Instruction book IQAN-MDM Publ. no. HY17-8328/UK Edition June, 2007 Contents 1 Introduction...............................................................3 Safety symbols................................................................
More informationYou Must Know About the New RIA Automation Standard
You Must Know About the New RIA Automation Standard AMT Decoding the essentials of RIA R15.06:2012 The new Robotics Industry Association (RIA) standard for robots and robot systems (RIA R15.06:2012) will
More informationMultizone Application 1 2-3 >3. MSR300 System. No Software configurable? GuardPLC. Enet RECOMMENDED PRODUCTS. Time Delay MSR138
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr Selection Flowchart Multizone Application General
More informationR4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
More informationGuidelines. Safety Integrity Level - SIL - Valves and valve actuators. March 2009. Valves
Valves Guidelines Safety Integrity Level - SIL - Valves and valve actuators March 2009 VDMA German Engineering Federation Valves Manufacturers Association Chairman: Prof.-Dr.-Ing. Heinfried Hoffmann Managing
More informationNEC Class 2 Power Circuits and Power Supplies
NEC Class 2 Power Circuits and Power Supplies Abstract: The NEC (National Electrical Code) is a North American standard, which can be regarded as a law in most of the North American states. Among others,
More informationSINEAX U553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
More informationEasy Multifunctional Safe
EMS Electronic motor starters www.eaton.eu Easy Multifunctional Safe EMS Multifaceted Performance with only 0 mm Eaton Moeller series products have always embodied quality and reliability in the machine
More informationKvaser Mini PCI Express User s Guide
Kvaser Mini PCI Express User s Guide Copyright 2013-2014 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Printed Sunday 28 th September, 2014 We believe that the information contained herein was accurate
More informationContact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61400-1 Second edition 1999-02 Wind turbine generator systems Part 1: Safety requirements Aérogénérateurs Partie 1: Spécifications de sécurité IEC 1999 Copyright - all rights
More informationOil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
More informationAutomation, Software and Information Technology. Test report of the type approval safety-related automation devices
Automation, Software and Information Technology Test report of the type approval safety-related automation devices GuardPLC 1200 GuardPLC 1600 GuardPLC 1800 GuardPLC 2000 GuardPLC Distributed I/O Report-No.:
More informationfunctional Safety UL Functional Safety Mark
functional Safety UL Functional Safety Mark Program UL Functional Safety Mark Program With the advent and evolution of functional safety standards in North America and Europe, UL is now offering a UL Functional
More informationExperience with taximeters with a look at the corresponding tables
Experience with taximeters with a look at the corresponding tables Milan Prasil CMI Laboratory of the fundamental metrology V Botanice 4, 150 72 Prague 5 mprasil@cmi.cz Taximeters in EU are subject to
More informationFL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5
T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),
More informationpsens Pressure Measurement
Mobile Machine Control Solutions psens Pressure Measurement Reliable Compact Versatile Unique Measurement Accuracy psens. Pressure Sensors from Hirschmann MCS Hirschmann pressure transducers are an ideal
More informationContact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
More informationFMEDA and Proven-in-use Assessment. Pepperl+Fuchs GmbH Mannheim Germany
FMEDA and Proven-in-use Assessment Project: Inductive NAMUR sensors Customer: Pepperl+Fuchs GmbH Mannheim Germany Contract No.: P+F 03/11-10 Report No.: P+F 03/11-10 R015 Version V1, Revision R1.1, July
More information