1 VWR ph & REDOX ELECTRODES For every application For any ph meter Reliable performance
2 VWR ph & REDOX ELECTRODES LABORATORY AND FIELD ELECTRODES FOR EVERY APPLICATION AND ph METER Compact electrodes for general use, small samples, surface measurements and semi-solid samples Comfortable handling and reliable functionality Quality assured All VWR electrodes are checked, at 2 points (Universal electrodes) and 5 points (phenomenal ), during the manufacturing process and then lot stamped to ensure quality Every electrode is supplied with a soaker storage cap to ensure the ph sensitive glass and reference junction is in top condition and instantly ready for use phenomenal models come with a quality certificate and serial number making documentation and traceability easier Technical specifications Parameter Specification Universal phenomenal ph range 0-14 ph Temperature range ( C) 0-80 for epoxy body Diaphragm Electrolyte Single or double for glass body 80 for epoxy body Single junction or platinum Gel or liquid Redox Redox range ±2000 mv Temperature range ( C) 0-80 for epoxy body 0-80 glass body for glass body - Type Model DxH (mm) Connection SJ113 12x120 BNC Single junction SJ114 12x120 DIN SJ x120 S DJ x120 BNC Double junction DJ114 12x120 DIN DJ115 12x120 S SF113 12x120 BNC Surface SF114 12x120 DIN SF115 12x120 S EPOXY SHAFT AND GEL ELECTROLYTE Type Model DxH (mm) Connection Single junction Surface Semi-micro Spear electrode SJ223 12x120 BNC SJ224 12x120 DIN SJ225 12x120 S SF223 12x120 BNC SF224 12x120 DIN SF225 12x120 S SM223 6x120 BNC SM224 6x120 DIN SM225 6x120 S SP223 12/6x120 BNC SP224 12/6x120 DIN SP225 12/6x120 S GLASS SHAFT AND LIQUID ELECTROLYTE Ag/AgCl - 3 MOL/l KCl 2 VWR INTERNATIONAL VWR COLLECTION PRODUCTS: DELIVERING HIGH QUALITY & SUPERIOR PERFORMANCE
3 UNIVERSAL CABLES FOR ph ELECTRODES - 1 m Cable with BNC connector Coax Cable with DIN connector Coax Cable with EE connector (Radiometer) Coax Cable with R connector (Metrohm) Coax PHENOMENAL PH ELECTRODES WITH BNC CONNECTOR Model Type Built-in temperature sensor *3 m cable Electrodes with epoxy shaft and gel electrolyte with 1 m cable. DxH 12x120 mm phenomenal 110 phenomenal 111 phenomenal 111-3* No Yes Yes Electrodes with glass shaft and Ag/AgCl - 3 mol/l KCl liquid electrolyte with 1 m cable. DxH 12x120 mm phenomenal 211-3* phenomenal 220 phenomenal 221 phenomenal LS 221 platinum Yes No Yes Yes phenomenal MIC 220 Semi-micro No Glass electrode with gel fill, 1 m cable. DxH 12/6x120 mm phenomenal SPEAR 220 Spear electrode No REDOX ELECTRODES WITH 1 m CABLE AND BNC CONNECTOR DxH (mm) Model Type Body shaft Electrolyte 12x120 RD 113 Plastic redox electrode 12x120 RD 223 Glass redox electrode 12x120 phenomenal ORP 220 Glass redox electrode Epoxy Gel Glass 3,5 M KCl Glass 3,5 M KCl VWR COLLECTION PRODUCTS: DELIVERING HIGH QUALITY & SUPERIOR PERFORMANCE VWR INTERNATIONAL 3
4 VWR ph & REDOX ELECTRODES Application guide: Application area Sub segment Single junction SJ 113 / 114 / 115 phenomenal 110 / 111 Gl Agriculture Fertiliser solutions Beverage Chemistry Cosmetics Fruits Soil (eluate) Vegetables Beer Fruit juice Mineral water Spirits/wine Acids solutions Bleach and dying solutions Emulsions Electroplating bath and pickling Ink Oil/water emulsions Paint/varnish Viscose samples Semi-solid samples Creme Lotion Make-up Shampoos Shaving foam Soap Toothpaste Education Economic General purpose Research grade Field measurements Ground, lake and river Food Dairy Pharma/Biotech Surface Washing agents Rain water Seawater Bread Coffee Honey Jam Marmelade Mayonnaise Meat/fish Butter Cheese Cream Milk Yoghurt Agar-agar gel Bacteria culture Enzyme solutions Serum Small sample quantity Tris buffer Paper Skin Textile Detergents Dishwashing liquid Disinfectant Soap solution Water Aquarium Cooling water Drinking water Purity water Salt water Wastewater, general 4 VWR INTERNATIONAL VWR COLLECTION PRODUCTS: DELIVERING HIGH QUALITY & SUPERIOR PERFORMANCE
5 ass single junction SJ 223 / 224 / 225 Double junction DJ 113 / 114 / 115 phenomenal glass electrodes 211 / 220 / 221 phenomenal glass electrodes LS 221 Surface SF 113 / 114 / 115 Surface SF 223 / 224 / 225 Semi-micro SM 223 / 224 : 225 phenomenal semimicro MIC 220 Spear elecrode SPEAR 223 / 24 / 225 phenomanal spear elecrode SPEAR 220 VWR COLLECTION PRODUCTS: DELIVERING HIGH QUALITY & SUPERIOR PERFORMANCE VWR INTERNATIONAL 5
6 VWR ph & REDOX ELECTRODES Ready to use ph buffers: AVS TITRINORM Traceable to SRM (Standard Reference Materials) from NIST Batch number and packing date for traceability Certificate of analysis available on the web Supplied in 100 ml bottles AVS TITRINORM buffer solution ph ph ph Coloured buffer dosing bottles Packed in an innovative twin neck, 1 l bottle, the buffer stock is protected from contamination once the bottle is open, while the correct amount is dispensed into the calibration chamber for use. Better buffer stability when the bottle is opened Traceability to SRM from NIST Easy to carry, ideally suited for field work No additional containers needed Less waste Description ph 4,00 (red coloured) ph 7,00 (green coloured) ph 9,00 (blue coloured) Buffers secondary standards Solution standardised at 25 ºC Accurate to ±0,01 ph units (except ph>10 with 0,05 ph units) Traceable to NIST, DIN19266 and IUPAC ISO compliant Supplied with Certificate of Analysis T dependance data is printed on the labels as are batch number and expiry date Supplied in 500 ml plastic bottles Description ph 1, ph 3, ph 4, ph 6, ph 7, ph 9, ph 10, ph 12, Maintenance and cleaning solutions Description Pk (ml) BDH Prolabo KCl (3 mol/l) electrolytic solution BDH Prolabo cleaning solution VWR INTERNATIONAL VWR COLLECTION PRODUCTS: DELIVERING HIGH QUALITY & SUPERIOR PERFORMANCE
7 ACCESSORIES Articulated stand for 4 electrodes and temperature sensor Storage vessel for ph electrodes (12 mm diameter) with bayonet connector Electrode storage tube for transportation VWR FOR ALL YOUR ELECTROCHEMISTRY NEEDS CONDUCTIVITY DISSOLVED OXYGEN MULTI-PARAMETER METERS, ELECTRODES/SENSORS, BUFFERS, STANDARDS AND REFERENCE MATERIALS...AND MUCH MORE CHECK OUT VWR.COM OR CONTACT YOUR LOCAL VWR SALES OFFICE. VWR COLLECTION PRODUCTS: DELIVERING HIGH QUALITY & SUPERIOR PERFORMANCE VWR INTERNATIONAL 7
ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:
BOECO PORTABLE PH/ORP/TEMP METER MODEL PT-380 A Simultaneous displays ph or mv and temperature. A Convenient calibration with automatic buffer recognition of European and US buffer sets. Calibration data
More informationLaboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen
Laboratory Electrochemistry Products ph Conductivity Dissolved Oxygen Spoilt for choice Small footprint Adjustable viewing angle Wall mountable New style electrode holder Contents page Overview................................3
More informationCompact ph Measuring Instruments
testo 205, 206, 230 Compact ph Measuring Instruments With innovative probe engineering ph C The new ph measuring instruments with innovative probe engineering Measurement of the ph value plays an important
More informationOPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S
Pen type, separate electrode SOIL PH METER Model : PH-220S Your purchase of this SOIL PH METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and
More informationJUMO tecline HD ph and JUMO tecline HD Rd
Page 1/7 JUMO tecline HD ph and JUMO tecline HD Rd ph and redox combination electrodes in glass shaft version Series 201021 ph electrodes Series 201026 redox electrodes Brief description JUMO tecline HD
More informationUSEPA Electrode Method Method 8156
ph DOC316.53.01245 USEPA Electrode Method Method 8156 Scope and application: For drinking water 1, wastewater 2 and process water. 1 Based on Standard Method 4500-H+B, ASTM Method D1293-95 and USEPA Method
More informationSenTix 950 SenTix 980
SenTix 950 SenTix 980 ph combination electrodes with refillable liquid reference system Operating manual ba75843e01 08/2009 SenTix The latest version of the present operating manual can be found on the
More informationph Measurements of Common Substances
Chem 100 Section Experiment 10 Name Partner s Name Introduction ph Measurements of Common Substances The concentration of an acid or base is frequently expressed as ph. Historically, ph stands for the
More informationph Measurement and Control
ph Measurement and Control Tech Tip #14 1997 I. The Need for ph II. ph System Requirements III. ph Electrode Conditioning Procedures IV. How the electrode works V. Identifying the Electrode Components
More informationIon Selective Electrodes
Ion Selective Electrodes OAKTON has a large selection of Ion Selective Electrodes () to suit a wide variety of applications. Each electrode has a typical response time of 20 to 30 seconds but will vary
More informationHousehold Acids and Bases
Household Acids and Bases GRADE LEVEL INDICATORS Experiment Demonstrate that the ph scale (0-14) is used to measure acidity and classify substances or solutions as acidic, basic, or neutral. 21 Develop
More informationHandbook. Thermo Scientific. ph Electrode Selection Handbook
Handbook Thermo Scientific ph Electrode Selection Handbook Table of Contents ph Theory... 4 ph Electrode Theory... 4 ph versus Temperature Theory... 5 ph Electrode Selection Guide... 6 Thermo Scientific
More informationREDOX AND REFERENCE ELECTRODE USER MANUAL
REDOX AND REFERENCE ELECTRODE USER MANUAL 3 Redox and reference electrode manual Copyright 2012 Unisense A/S Version October 2012 REDOX AND REFERENCE ELECTRODE MANUAL UNISENSE A/S TABLE OF CONTENTS WARRANTY
More informationConductivity and TDS Meters
Table of Contents Comparison Charts Introduction Portable Meters Waterproof Meters Printing & Logging Portable Meters Bench Meters Combination EC/TDS/pH Meter Page G2 G3 G6 G11 G14 G15 G16 G1 Comparison
More informationELECTROCHEMISTRY. Theory and Practice
ELECTROCHEMISTRY Theory and Practice Dr. Axel Bier Lab Product Application Manager - Electrochemistry For more information, please visit: www.hach.com/smartprobes P a g e 2 CONTENT INTRODUCTION 3 HOW TO
More informationHND-R. Hand-held ph, Redox and Temperature Measuring Units
Hand-held ph, Redo and Temperature Measuring Units measuring monitoring analysing HND-R A1 P? OMeasuring O range: ph: 0.00...14.00 Redo (ORP): -1999 mv... +2000 mv Temperature: -5 C...+150 C rh: 0.0 rh...
More informationCompact Water Quality Meter B-700 series
Compact Water Quality Meter B-700 series Actual Size Compact Water Quality Meter Debut! HORIBA s 60 years of sensor engineering realize accurate direct measurement from only a single drop on the unique
More informationLesson Plan: How Do We Know What is Healthy Water?
Lesson Plan: How Do We Know What is Healthy Water? Estimated Time: 1-3 days ph /Chlorine / Hardness State Standards taught and addressed Grade 8: Standards Taught (and evaluated at end of lesson) Science
More informationResolution selectable from 0.01 and 0.001 ph. Range -2.000 16.000 ph. Accuracy ± 0.002 ph
ph EC DO ph Resolution selectable from 0.01 and 0.001 ph Range -2.000 16.000 ph Accuracy ± 0.002 ph Data logging Manual log on demand manual log on stability Interval logging Temperature readout ( C or
More informationEutech 2700 Series. Bench Meters. ph ORP ION Conductivity TDS Salinity Resistivity Dissolved Oxygen Temperature
Eutech 2700 Series Bench Meters ph ORP ION Conductivity TDS Salinity Resistivity Dissolved Oxygen Temperature Features Comprehensive Backlit Display All Measurements Include Temperature Display Up To 500
More informationMeasurement by Ion Selective Electrodes
Measurement by Ion Selective Electrodes Adrian Vazquez May 8, 2012 Why Use Ion Selective Electrodes? Responsive over a wide concentration range Not affected by color or turbidity of sample Rugged and durable
More informationIon-selective Measurements
Ion-selective Measurements Ion-selective measurement is a method for determining the concentration of dissolved ions. Potassium ions, sodium ions, fluoride or chloride are examples of such cations and
More informationJUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor
Vorläufig V Page 1/8 JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor Cell constants K = 0.01 1.0 202922 Series for universal application, e.g. drinking and surface water monitoring,
More informationAcids, Bases, and ph
CHAPTER 9 1 SECTION Acids, Bases, and Salts Acids, Bases, and ph KEY IDEAS As you read this section, keep these questions in mind: What properties do acids have? What properties do bases have? How can
More informationph, redox and I.S.E. electrodes
ph, redox and I.S.E. electrodes Complete and clear offer which makes easy the choice of the suitable model without user s confusion. ph electrodes: four models for portable instrument, five basic laboratory
More informationWORKSHEET: ph and Water 23 Lab Instructor: Lab Day & Time: Student name(s): drain cleaner flat soda pop window cleaner ammonia.
WORKSHEET: ph and Water 23 Lab Instructor: Lab Day & Time: Student name(s): DATA AND ANALYSIS ph Substance ph Value Substance ph Value Substance ph Value pure water apple juice dish soap sugar water beer
More informationChapter 6. Solution, Acids and Bases
Chapter 6 Solution, Acids and Bases Mixtures Two or more substances Heterogeneous- different from place to place Types of heterogeneous mixtures Suspensions- Large particles that eventually settle out
More informationA Useful Tool for the Determination of Consistency in Semi-Solid Substances
A Useful Tool for the Determination of Consistency in Semi-Solid Substances By Wayne S. Goldenberg, Ph.D. and Raj Shah, Ph.D. Koehler Instrument Company, Inc., New York Consistency (i.e., thickness or
More informationTotal Dissolved Solids:
Total Dissolved Solids: Going From Tedious to TDS Michael Bechtold, Technical Specialist David Smith, Technical Director Total Dissolved Solids (TDS) What is it and why does it matter? How is it currently
More informationSTOCKMEIER water chemicals Strong bonds for clear water
STOCKMEIER water chemicals Strong bonds for clear water Water a strong compound for life Why H O is so unique Water, the source of all life. Without water, life would never have developed on our planet
More informationChem 100 Lab Experiment #9 - ACID/BASE INDICATORS
Lab #9 Chem 100 Lab Experiment #9 - ACID/BASE INDICATORS Name: Purpose: In this laboratory we will investigate how indicators can be used to test for the presence of acids or bases in a number of common
More informationEXPERIMENT 20: Determination of ph of Common Substances
Materials: ph paper and color chart (ph range 3 to 12) or ph meter distilled water white vinegar household ammonia (or baking soda) spot plate test or 3 small test tubes stirring rod solutions / fruits
More informationORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
More informationRBS detergents for laboratories
RBS detergents for laboratories High performance solutions For reliable and reproducible results Competence & experience RBS products are mainly intended for water-based cleaning processes of glassware
More informationTeacher Demo: Turning Water into Wine into Milk into Beer
SNC2D/2P Chemical Reactions/Chemical Reactions and their Practical Applications Teacher Demo: Turning Water into Wine into Milk into Beer Topics evidence of chemical change types of chemical reactions
More informationCLEANING WATER. Student Section
National Aeronautics and Space Administration CLEANING WATER Student Section Student Name This lesson challenges you to create and test a water filtration system. During this lesson, you will design and
More informationEnvironmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater
Document: AND Sol Env 08 2013 Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater Matrix specific sample preparation and testing methods for environmental waters
More informationConductivity Theory and Practice
Conductivity Theory and Practice - 1 - - when you need to be sure... Preface The importance of conductivity Conductivity measurement is an extremely widespread and useful method, especially for quality
More informationThe Effects of Temperature on ph Measurement
The Effects of Temperature on ph Measurement Authors: John J. Barron Colin Ashton & Leo Geary Technical Services Department, Reagecon Diagnostics Ltd, Shannon Free Zone, County Clare, Ireland Abstract
More informationCHM 130LL: ph, Buffers, and Indicators
CHM 130LL: ph, Buffers, and Indicators Many substances can be classified as acidic or basic. Acidic substances contain hydrogen ions, H +, while basic substances contain hydroxide ions, OH. The relative
More informationOT 40L / 90L. Laboratory Steam Sterilizers
OT 40L / 90L Laboratory Steam Sterilizers OT 40L / 90L LABORATORY STEAM STERILIZERS OT 40L / OT 90L laboratory steam sterilizers are specially designed for the steam sterilization of liquid and culture
More informationCare, Maintenance, and Storage of YSI 6-Series Probes and Sondes
Tech Note Care, Maintenance, and Storage of YSI 6-Series Probes and Sondes Probe Care and Maintenance Periodic cleaning and membrane changes are required to keep your sensors operating properly. Follow
More informationWherever chemical solutions are involved, ph matters. Some
47 Acids, Bases, and the ph Scale r e a d i n g Wherever chemical solutions are involved, ph matters. Some important chemical reactions, such as those involved in corrosion of iron or digestion of food,
More informationConductivity measurements are used for applications such as in the production of ultrapure water or determining the salinity of sea water.
Meters Meters is a parameter used to measure the ionic concentration and activity of a solution. The more salt, acid or alkali in a solution, the greater its conductivity. The unit of conductivity is S/m,
More informationYour 2015 / 2016 Recycling Guide. We re recycling are yo? wasteteam@chiltern.gov.uk wasteteam@wycombe.gov.uk www.chiltern.gov.uk www.wycombe.gov.
Your 2015 / 2016 Recycling Guide We re recycling are yo? 01494 586550 wasteteam@chiltern.gov.uk wasteteam@wycombe.gov.uk www.chiltern.gov.uk www.wycombe.gov.uk Mixed recycling blue wheeled bin or reusable
More informationHow to Use Water Safely in Your Food Establishment During a Boil Water Advisory
How to Use Water Safely in Your Food Establishment During a Boil Water Advisory Food service establishments are allowed to operate during the boil water advisory as long as the conditions outlined below
More informationKemet DIAMOND PRODUCTS
Kemet DIAMOND PRODUCTS Kemet Diamond Products Since 1938, Kemet has been at the forefront of precision polishing technology, producing quality diamond pastes, slurries and composite lapping/polishing materials
More informationCare. Drinks. Tissues. 2014 collection. Sun protection, lips, Fair Trade, condoms, nails, first aid, dental, cosmetic bags
ROMOTIONAL 2014 collection Drinks Spring water, coloured caps, mineral water, sports cap Tissues Square, pocket, nose, book style, wet wipes Care Sun protection, lips, Fair Trade, condoms, nails, first
More informationHow To Understand The Cottage Foods Act
Cottage Foods Act Frequently Asked Questions WEBINAR AND RESOURCES For more information, check the Colorado Department of Public Health and Environment Division of Environmental Health and Sustainability
More informationMilwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01
Milwaukee Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: SM600 Smart DO Meter Authorized Dealer: ISMIL600 11/01 PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery
More informationAIRMoN, ph and Conductivity Field Measurement
AIRMoN, ph and Conductivity Field Measurement Items needed: Sample to be measured (sample volume 50 ml) Field Observer Form (FOF) for the sample to be measured conductance cell ph vials, 4 conductivity
More informationDirect ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE
Sodium DOC316.53.01240 Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE Scope and application: For drinking water and process water. Test preparation Instrument-specific information This procedure
More informationMeasuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3
Measuring ph in Water or CaCl2 Using a ph Meter Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3 PREPARING THE ph METER FOR USE (Calibration and Buffer Solutions) 4 When is Calibration
More informationCare and use guide. Contents. a handy solution made easy. www.getbluelab.com. page
Care and use guide Contents page Features Quick guide Before use To operate Important - ph pen probe care 4 Cleaning 5 Battery replacement 5 Hydration 6 Calibration 6 Error messages 7 Troubleshooting guide
More informationDonau Kanol GmbH & Co KG Organization. Jänner 15 2012 Donau Chemie Gruppe
Donau Kanol GmbH & Co KG Organization 2 Site map organization 3 4 Production sites in Austria Pischelsdorf Ried/Traunkreis 5 Landeck Brückl 6 Donau Kanol from vision to product Biggest Austrian contract
More informationNational Food Safety Standard Food microbiological examination: Aerobic plate count
National Food Safety Standard of the People s Republic of China GB4789.2-2010 National Food Safety Standard Food microbiological examination: Aerobic plate count Issued by 2010-03-26 Implemented by 2010-06-01
More informationLab Exercise 3: Media, incubation, and aseptic technique
Lab Exercise 3: Media, incubation, and aseptic technique Objectives 1. Compare the different types of media. 2. Describe the different formats of media, plate, tube etc. 3. Explain how to sterilize it,
More informationChapter 3: Separating Mixtures (pg. 54 81)
Chapter 3: Separating Mixtures (pg. 54 81) 3.2: Separating Mechanical Mixtures (PB Pg. 40 5 & TB Pg. 58 61): Name: Date: Check Your Understanding & Learning (PB pg. 40 & TB pg. 61): 1. What are four methods
More informationMembrane Filtration Technology: Meeting Today s Water Treatment Challenges
Membrane Filtration Technology: Meeting Today s Water Treatment Challenges Growing global demand for clean water and increasing environmental concerns make membrane filtration the technology of choice
More informationwww.sampling.com World Class Equipment worldwide Edition J
www.sampling.com World Class Equipment worldwide Edition J Welcome Welcome to the latest edition of our Range Brochure Firstly, we would like to thank you our customers for helping us create the new range
More informationA Potentiometric Analysis of Fluoride Ion in Toothpaste
CHEM 311L Quantitative Analysis Laboratory Revision 2.0 A Potentiometric Analysis of Fluoride Ion in Toothpaste In this laboratory exercise, we will analyze a toothpaste sample for its Fluoride Ion (F
More informationStainless Steel Dissolved Oxygen Electrodes
Stainless Steel Dissolved Oxygen Electrodes DISSOLVED OXYGEN ELECTRODES The steam sterilizable family of dissolved oxygen electrodes from the phoenix Electrode Company is specifically designed for fermentation
More informationBlood Collection and Processing SOP
Brisbane Breast Bank Blood Collection and Processing SOP Breast Pathology Laboratory University of Queensland Centre for Clinical Research Blood Collection We collect 30ml of blood from patients who have
More informationMilwaukee USER MANUAL
Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: MW600 Smart DO Meter PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery compartment cover on the back of the
More informationConductivity measurement on pure water according to the recommendations of the USP Pharmacopoeia USP24-NF19
Conductivity measurement on pure water according to the recommendations of the USP Pharmacopoeia USP24-NF19 By Patricia DALMAS, Product Specialist, Radiometer Analytical Pharmaceutical laboratories working
More informationWASTEWATER TREATMENT OBJECTIVES
WASTEWATER TREATMENT OBJECTIVES The student will do the following: 1. Define wastewater and list components of wastewater. 2. Describe the function of a wastewater treatment plant. 3. Create a wastewater
More informationfor Dundee Your NEW recycling service What s new What you should recycle Your containers Find out more inside
for Dundee Your NEW recycling service What s new What you should recycle Your containers Find out more inside 1 for Dundee What can be recycled using this service? NEW Your NEW recycling service. We have
More informationCONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor
CONDUCTIVITY SENSOR Description D0382 Figure 1. The Conductivity Sensor Short Description The Conductivity Sensor can be used to measure either solution conductivity or total ion concentration of aqueous
More informationAcids and Bases. AND a widemouth container of the following solids:
Acids and Bases GOAL To introduce students to acids and bases. MATERIALS: 3 10oz clear plastic cups 1 4 oz. bottle white vinegar - labeled Acid 1 4 oz. bottle of water - labeled Water 1 4 oz. bottle of
More informationChapter 6: Mixtures. Overall Objectives 46. 6.1 Introduction 46. Time Required: 6.2 Types of mixtures 46
Chapter 6: Mixtures Overall Objectives 46 6.1 Introduction 46 6.2 Types of mixtures 46 6.3 Like dissolved like 46 6.4 Soap 47 6.5 Summary 47 Experiment 6: Mix it Up! 48 Review 52 Notes 52 Time Required:
More informationMicrobiological Testing of the Sawyer Mini Filter. 16 December 2013. Summary
Microbiological Testing of the Sawyer Mini Filter 16 December 2013 Summary The Sawyer Mini Filter was tested for its ability to remove three microorganisms Raoultella terrigena, Bacillus subtilis, and
More informationFluoride Strengthens Teeth
Fluoride Strengthens Teeth Two hard-boiled eggs Fluoride gel or solution, 4 to 6 oz. (from dental office) Three clean plastic containers Several cans of dark soda Water 1. Place a hard-boiled egg in one
More informationDepletion Respiration
Depletion Respiration Depletion The investigation and monitoring of biological cleaning treatment processes are becoming more and more important with respect to the environmental requirements such as wastewater
More informationNutrition and Chronic Kidney Disease
Nutrition and Chronic Kidney Disease I have been told I have early kidney failure. What does this mean? What can I expect? This means that your kidneys are not doing as good a job as they should to help
More informationPrevent & Save. Best Practice Guidelines in Waste Management. Waste Management for the Hospitality Industry
Prevent & Save Best Practice Guidelines in Waste Management Waste Management for the Hospitality Industry QUANTIFIABLE TONNES OF PACKAGING WASTE The most important aspect of waste management is having
More informationDNA SPOOLING 1 ISOLATION OF DNA FROM ONION
DNA SPOOLING 1 ISOLATION OF DNA FROM ONION INTRODUCTION This laboratory protocol will demonstrate several basic steps required for isolation of chromosomal DNA from cells. To extract the chromosomal DNA,
More informationPhosphorus, Reactive (Orthophosphate)
Phosphorus, Reactive (Orthophosphate) DOC316.53.01113 Amino Acid Method 1 Method 8178 0.23 to 30.00 mg/l PO 4 Reagent Solution Scope and application: For water, wastewater and seawater. 1 Adapted from
More informationStandard buffer solutions for ph-meter calibration. Reliable Traceable to NIST Tested according to DIN 19266 and DIN 19268 Supplied with certificate
Reliable Traceable to NIST Tested according to DIN 19266 and DIN 19268 Supplied with certificate ph value is probably the most common of all routinely performed measurements in laboratories. Since ph-value
More informationDATA CAPTURE. Helpline: 018101123, 018427450-1, 08033066006, 08067326404, 08034412170
DATA CAPTURE Helpline: 018101123, 018427450-1, 08033066006, 08067326404, 08034412170 What you should know All documents to be uploaded must be PDF and Excel (for Global Listing only) documents and not
More informationChemists use the ph value to measure how acidic or basic a solution is. The ph scale runs from 0 to 14:
The ph Value Chemists use the ph value to measure how acidic or basic a solution is. The ph scale runs from 0 to 14: If the ph value is lower than 7 (0 to 6.99) the solution contains more H + ions than
More informationph and Acidity in Wine and Fruit Juice
ph and Acidity in Wine and Fruit Juice DOC316.52.93089 Endpoint potentiometric titration Scope and application: Wine and fruit juice 1. Introduction This working procedure refers to the titration of total
More informationAppendix C. Vernier Tutorial
C-1. Vernier Tutorial Introduction: In this lab course, you will collect, analyze and interpret data. The purpose of this tutorial is to teach you how to use the Vernier System to collect and transfer
More informationTurbiDirect TurbiCheck TurbiCheck WL
Turbidity 128 TurbiDirect TurbiCheck TurbiCheck WL www.lovibond.com General Catalogue February 2013 Turbidity measurement The term "turbidity is used to describe the cloudy or milky appearance of liquid
More informationSINGLE RANGE DS METERS Operation Instructions
SINGLE RANGE DS METERS Operation Instructions User Manual for Models 512T2 512T3 512T4 512T5 512T10 512M2 512M3 512M4 512M5 512M10 6115 Corte del Cedro Carlsbad, CA 92009-1516 USA Tel 760-438-2021 Fax
More informationLABOKLAV. Autoclaves Made in Germany. www.shp-steriltechnik.de
LABOKLAV Autoclaves Made in Germany www.shp-steriltechnik.de 2 LABOKLAV STEAM STERILIZERS Steam sterilization is the sterilization method with the widest range of applications efficient, safe, reproducible
More informationCh. 57 MILK AND DAIRY PRODUCTS 7 CHAPTER 57. MILK AND DAIRY PRODUCTS GENERAL PROVISIONS
Ch. 57 MILK AND DAIRY PRODUCTS 7 CHAPTER 57. MILK AND DAIRY PRODUCTS GENERAL PROVISIONS Subchap. Sec. A. MILK AND DAIRY PRODUCTS DEFINITIONS AND STANDARDS... 57.1 B. LABELING... 57.41 C. OTHER DAIRY PRODUCTS...
More informationSyllabus OC18 Use litmus or a universal indicator to test a variety of solutions, and classify these as acidic, basic or neutral
Chemistry: 9. Acids and Bases Please remember to photocopy 4 pages onto one sheet by going A3 A4 and using back to back on the photocopier Syllabus OC18 Use litmus or a universal indicator to test a variety
More informationIntroduction. ph = log [H + ]
Visualizing ph 2010, 1992 by David A. Katz. All rights reserved. Permission granted for classroom use. All reproductions must include original copyright. David A. Katz Chemist, Educator, Science Communicator,
More informationIgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.
IgM ELISA For the quantitative determination of IgM in human serum and plasma For Research Use Only. Not For Use In Diagnostic Procedures. Please read carefully due to Critical Changes, e.g., Calibrator
More informationSyllabus M.Tech. Food Technology DSC- FT- 1 A: FUNDAMENTALS OF FOOD SCIENCE AND TECHNOLOGY PART I
Syllabus M.Tech. Food Technology DSC- FT- 1 A: FUNDAMENTALS OF FOOD SCIENCE AND TECHNOLOGY PART I Unit 1 Introduction to Food Science and Technology Definition, scope and current trends in food science
More informationCity of Cardiff Council Commercial Waste Service
City of Cardiff Council Commercial Waste Service Don t throw your money away. Reduce waste. REDUCE - REUSE - RECYCLE - 02920 717501 CONTENTS 1) Introduction... Page 1 2) Our services... Page 2 2a) Waste
More informationDetermination of raw milk quality
MILK ~ 1 ~ Determination of raw milk quality Milk evaluation during reception and sampling rules According to PN-A-86040 1. Sample of milk could pick up only authorized person 2. Tools and vessels have
More informationFarmer s Markets. Regulatory Considerations for Tennessee Food Manufacturers. Mike Brown Outreach Coordinator Tennessee Department of Agriculture
Farmer s Markets Regulatory Considerations for Tennessee Food Manufacturers Mike Brown Outreach Coordinator Tennessee Department of Agriculture Agencies Federal USDA Meat and Poultry Catfish Egg Products
More informationExpertise in liquid analysis From sensors to complete turnkey solutions
Products Solutions Services Expertise in liquid analysis From sensors to complete turnkey solutions Liquid analysis 2 The Liquiline Family The Liquiline Family 3 Memosens - The digital revolution in process
More informationYour NEW. recycling service. household waste. and. Your new recycling guide What to recycle How to recycle Find out more inside
Your NEW household waste and recycling service Your new recycling guide What to recycle How to recycle Find out more inside Your new service We have made changes to your household waste and recycling service
More informationAcid 7 Base. 1. Describe two things hydrochloric acid does in your body system. 2. What does sodium hydrogencarbonate do in your body system?
Acids and Bases acid: a compound that, when dissolved in water, forms a solution with a ph less than 7 base: a compound that, when dissolved in water, forms a solution with a ph greater than 7 ph: the
More informationExperiment 9: Acids and Bases Adapted from: Chemistry, Experimental Foundations, 4th Ed. Laboratory Manual, by Merrill, Parry & Bassow.
Chem 121 Lab Clark College Experiment 9: Acids and Bases Adapted from: Chemistry, Experimental Foundations, 4th Ed. Laboratory Manual, by Merrill, Parry & Bassow. Content Goals: Increase understanding
More informationROTARY PISTON PUMPS THE FEED PUMP TYPE SKK. The variants of the feed pump SKK. Range of pumping liquids (extr.) Reference technical data.
ROTARY PISTON PUMPS THE FEED PUMP TYPE The variants of the feed pump Type rotation-independent safe to run dry (no metal contact) sturdy construction with one-sided bearing power transmission gears in
More information5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS
5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS Sl. No. Contents Preamble 5.1 Aim 5.2 Introduction 5.2.1 Environmental Significance 5.3 Principle 5.4 Materials Required 5.4.1 Apparatus Required 5.4.2
More informationProperties of Acids and Bases
Lab 22 Properties of Acids and Bases TN Standard 4.2: The student will investigate the characteristics of acids and bases. Have you ever brushed your teeth and then drank a glass of orange juice? What
More information