1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Size: px
Start display at page:

Download "1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI"

Transcription

1 Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure transmitter measures the liquid levels in tanks, containers, channels and dams. The SITRANS LH00 pressure transmitters are available for various measuring ranges and with explosion protection as an option. A junction box and a cable hanger are available as accessories for simple installation. Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm Benefits Compact design Simple installation Small error in measurement (0. %) Degree of protection IP68 Application SITRANS LH00 pressure transmitters are used in the following branches, for example: Shipbuilding Water/waste water supply For use in unpressurized/open vessels and wells The pressure transmitter has a built-in ceramic sensor which is equipped with a Wheatstone resistance bridge. These pressure transmitters are equipped with an electronic circuit fitted together with the sensor in a stainless steel housing. In addition, the connecting cable contains a vent pipe which is equipped with a humidity filter to prevent the build-up of condensation. The diaphragm is protected against external influences by a protective cap. The sensor, the electronics and the connecting cable are housed in an enclosure with small dimensions. The pressure transmitter is temperature-compensated for a wide temperature range. SITRANS LH00 pressure transmitter, mode of operation and connection diagram On one side of the sensor (), the diaphragm () is exposed to the hydrostatic pressure which is proportional to the submersion depth. This pressure is compared with atmospheric pressure. Pressure compensation is carried out using the vent pipe () in the connecting cable. The vent pipe is equipped with a humidity filter which prevents the build-up of condenstation in the vent pipe. The hydrostatic pressure of the liquid column acts on the diaphragm of the sensor and transmits the pressure to the Wheatstone resistance bridge in the sensor. The output voltage of the sensor is applied to the electronic circuit where it is converted into an output current of to 0 ma. The protective conductor connection/equipotential bonding () is connected to the enclosure. Integration It is generally recommended that the connecting cable of the SITRANS LH00 transmitter is connected to the junction box, which can be ordered separately, and secured with the cable hanger, also available separately. The junction box has to be installed near the measuring point. If the medium is anything other than water, it is also necessary to check compatibility with the specified materials of the transmitter. Venting pipe To measuredvalue processing To transmitter 7MF7 Junction box 7MF7-8AA, open, schematic diagram / Siemens FI 0 06

2 Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Technical specifications Measuring point setup, generally with junction box 7MF7-8AA and 7MF7-8AB cable hanger Pressure transmitter SITRANS LH00 (submersible sensor) Mode of operation Measuring principle piezo-resistive Input Measured variable Hydrostatic level Max. permissible operating pressure 0... mh O ( fth O). bar (.8 psi) (corresponds to mh O ( fth O)) 0... mh O (0... fth O). bar (.8 psi) (corresponds to mh O ( fth O)) 0... mh O (0... fth O). bar (.8 psi) (corresponds to mh O ( fth O)) mh O ( fth O). bar (.8 psi) (corresponds to mh O ( fth O)) mh O ( fth O).0 bar (. psi) (corresponds to 0 mho (90 ftho)) mh O ( fth O).0 bar (7. psi) (corresponds to 0 mh O (0 fth O)) bar.bar bar.bar bar.bar bar.bar 0... bar.0bar 0... bar.0bar Output Output signal...0 ma Measuring accuracy According to IEC Error in measurement at limit setting 0.% of full-scale value (typical) including hysteresis and reproducibility 0...mH O 0. % of full-scale value (typical) ( fth O bzw bar).0% of full-scale value (maximum) For all other measuring ranges 0. % of full-scale value (typical) 0.6% of full-scale value (maximum) Influence of ambient temperature Zero and span mh O (9 fth O or 0. bar) 0. %/0 K of full-scale value... 6 mh O 0. %/0 K of full-scale value (... 8 fth O or bar) 6mH O 0. %/0 K of full-scale value ( 8 fth O or 0.6 bar) Long-term stability Zero and span mh O (9 fth O or 0. bar) 0. % of full-scale value/year... 6 mh O 0.% of full-scale value/year (... 8 fth O or bar) 6mH O 0. % of full-scale value/year ( 8 fth O or 0.6 bar) Rated conditions Ambient conditions Process temperature C ( F) Storage temperature C ( F) Degree of protection according to IP68 IEC 609 Siemens FI 0 06 /

3 Siemens AG 06 Pressure transmitter 0. kg ( 0. lb) Cable; maximum cable length 00 m 0.0 kg/m ( 0.0 lb/ft) (0 ft) Electrical connection Cable with conductors, vent pipe and integrated humidity filter Material Seal diaphragm Al O ceramic, 96% Enclosure Stainless steel, mat. no..0/6l Gasket FPM (standard) EPDM (optional) Connecting cable PE-HD (standard) PE-LD (in the case of versions with EPDM seal, suitable for drinking water) Auxiliary power Terminal voltage on pressure transmitter U B V DC for transmitter with 0... V DC intrinsic safety explosion protection Certificates and approvals Drinking water approval (ACS) Applied for Drinking water approval (WRAS) 0 EAC TC RU C-DE.ГБ0.В.007 OC НАНИО «ЦСВЭ» Underwriters Laboratories (UL) E The transmitter is not subject to the pressure equipment directive (PED 0/68/EU) Explosion protection Intrinsic safety "i" IECEx SEV.000 SEV ATEX 009 -Marking II G Ex ia IIC T Ga Junction box Application for connecting the transmitter cable 0. kg (0. lb) Electrical connection x -way (8 to 8 AWG) Cable entry x Pg 9 Enclosure material polycarbonate Vent pipe for atmospheric pressure Screw for cable strength cord Rated conditions Degree of protection according to IP6 IEC 609 Cable hanger Application Material for mounting the transmitter 0.6 kg (0. lb) Galvanized steel, polyamide SITRANS LH00 Transmitter for hydrostatic level / Siemens FI 0 06

4 Siemens AG 06 Selection and ordering data Article No. Order code Pressure transmitter 7 M F A SITRANS LH00 (submersible sensor) For measurement of the hydrostatic level through submersion, two-wire system, 0 ma, enclosure material mat. no..0 (6L), measuring cell Al O ceramic, with permanently mounted PE cable Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Cable length 0...mH O ) 0 m } C 0... mh O 0 m } D 0... mh O 0 m } E mh O 0 m } F mh O 0 m } H mh O 0 m } K 0...9ftH O ) ft C 0... fth O ft D 0... fth O ft E fth O ft F fth O 66 ft H fth O 98 ft K bar ) 0 m C bar 0 m D bar 0 m E bar 0 m F 0... bar 0 m H 0... bar 0 m K Special versions: s for special versions between 0... mh O and mh O or fth O and fth O or bar and 0... bar possible. Special cable lenght/special measuring range Please add -Z to Article No. and 9 A H.. + Y 0 specify Order code and plain text. Note: Indication of measuring range Y0 is always necessary. For evaluation of the maximum possible cable length following data have to be regarded: Transmitter: C i = 0 µf, L i = 0 µh Cable: C k = 0.9 nf per meter cable L k =. µh per meter cable The maximum permitted data of the transmitter s power supply have to be considered! m (0 ft) H A m (6 ft) H B 7 m ( ft) H C 0 m ( ft) H D m (9 ft) H E 0 m (66 ft) H F m (8 ft) H G 0 m (98 ft) H H 0 m ( ft) H J 0 m (6 ft) H K 60 m (98 ft) ) H L 70 m ( ft) ) H M 80 m (6 ft) ) H N 90 m (97 ft) ) H P 00 m (0 ft) ) H Q SITRANS LH00 Transmitter for hydrostatic level Selection and ordering data Article No. Order code Pressure transmitter 7 M F A SITRANS LH00 (submersible sensor) For measurement of the hydrostatic level through submersion, two-wire system, 0 ma, enclosure material mat. no..0 (6L), measuring cell Al O ceramic, with permanently mounted PE cable Sealing material between sensor and enclosure FPM (Standard) } EPDM (for drinking water applications) Explosion protection without } 0 With ATEX II G Ex ia IIC T Ga and } IECEx Ex ia IIC T Ga Additional versions Order code Quality Inspection Certificate (-point C characteristic curve test) according to IEC , add "-Z" to article no. and add order code. Indication of measuring range (only at Y0 special cable lengths) in "... to... mh O" or "... to... fth O" or "... to... bar" Accessories/spare parts Article No. Junction box } 7MF7-8AA for connecting the transmitter cable Cable hanger for securing the pressure transmitter Protective caps as spare parts (0-pack) Humidity filters as spare parts (0-pack) } Available ex stock ) Approvals pending. } 7MF7-8AB } 7MF7-8AD } 7MF7-8AE Siemens FI 0 06 /

5 Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Dimensional drawings ~6. (.8) More information Determination of the measuring range for media with a density of 000 kg/m (medium water) Ø. (0.9) 6 Cable, sheat Ø.8 (0.9) (black, PE) - (green) + (brown) 6 Protective conductor connection/equipotential bonding (white) Vent pipe with humidity filter Ø (0.0) (inner diameter) Protective cap with x Ø. (0.0) holes (black, PPE) H r SITRANS LH00 pressure transmitter, dimensions in mm (inch) 86 (.9) (.0) 6 (.) Junction box, dimensions in mm (inch) 7 (.6) 7 (0.07) 7 (0.07) Fastening hole Vent valve Cable gland Pg 9, cable diameter... 8 mm ( ) 90 (7.) 9 (0.7) 86 (.9) 0 (.) 0 (.) Calculation of the measuring range: p = x g x H with: = density of medium g = local acceleration due to gravity H = maximum level Example: Medium: Diesel fuel, = 80 kg/m Acceleration due to gravity: 9.8 m/s Start-of-scale: 0 m Maximum level: 6.0 m Cable length: 0 m Calculation: p = 80 kg/m x 9.8 m/s x 6.0 m p = 0 0 N/m p = 00 mbar Transmitter to be ordered: 7MF7-FA Plus, if required, junction box 7MF7-8AA and cable hanger 7MF7-8AB 8 (.9) Cable hanger, dimensions in mm (inch) /6 Siemens FI 0 06

SITRANS F flowmeters SITRANS F M

SITRANS F flowmeters SITRANS F M Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update

More information

Features. Picture. Specifications

Features. Picture. Specifications Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61 Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:

More information

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP) Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219 Siemens AG 2010 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

Compact pressure switch Flameproof enclosure Ex d Model PCA

Compact pressure switch Flameproof enclosure Ex d Model PCA Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring

More information

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS EPP - 1 DECRIPTION The odel 575 is used in general water/wastewater applications. The transmitter is offered in a standard non-clogging snub nose end, flush diaphragm or protected flush diaphragm with

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

Micro Motion 3098 Gas Specific Gravity Meter

Micro Motion 3098 Gas Specific Gravity Meter Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry EX-Proof Stainless Steel Shaft Encoder - Ø 68 mm Shaft - Ø 10 mm to Ø 5/8 inch Resolution up to 10,000 ppr IP 66 (IP 67 option) ATEX certified EX-Proof IECEx certified EX-Proof

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration

More information

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

Plastic tube flowmeters Series PT/PS

Plastic tube flowmeters Series PT/PS Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

Flameproof Audible Signal 115 db (A) Series YA90

Flameproof Audible Signal 115 db (A) Series YA90 Clifford Snell www.stahl.de > Max sound output 115 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > 32 selectable tones meeting international regulations > Light

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

Technical Information RIA14

Technical Information RIA14 TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical

More information

Datalogger DL/N 70 Version: 28.03.2012

Datalogger DL/N 70 Version: 28.03.2012 Datalogger DL/N 70 Version: 28.03.2012 Technical Specifications Pressure measuring range (mh20) 1... 5 > 5... 20 > 20... 250 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure > 200 bar > 200 bar

More information

3DLevelScanner II TECHNICAL DATA SHEET

3DLevelScanner II TECHNICAL DATA SHEET TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Conductive Level Switch FK 2 Technical Data:

Conductive Level Switch FK 2 Technical Data: Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by

More information

1/2 NPTM. 29.21 mm 1.15. Nose cone fitting Ideal for clean liquids

1/2 NPTM. 29.21 mm 1.15. Nose cone fitting Ideal for clean liquids PT-500 Submersible Liquid Level Transmitter 1.0 Hex 25.4 mm 7.0 177.8 mm Re-Usable cage fitting Ideal for dirty liquids 5.63 143 mm 5.33 136 mm 1/2 NPTM 3.5 88.9 mm 1.15 29.21 mm Nose cone fitting Ideal

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100 Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When

More information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Control- and feedback head for integrated mounting on Robolux valves Type 2036 Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated

More information

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement. and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =

More information

Technical data sheet TDS0070

Technical data sheet TDS0070 Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

T U R B I N E G A S M E T E R

T U R B I N E G A S M E T E R TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss

More information

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Rosemount 752 FOUNDATION fieldbus Remote Indicator Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

Fluxi 2000/TZ Turbine Gas Meter

Fluxi 2000/TZ Turbine Gas Meter Gas Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas.

More information

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell MTB Load Cell Process Weighing Due to the hermetically sealed design, MTB is ideal for harsh environments in process or food applications. The full set of approvals makes it the right choice for your application.

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461 D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features GE Measurement & Control Solutions RTX 1000 Series Versatile Transmitters for a World of Pressure GE Measurement & Control Solutions is renowned for the design and manufacture of compact and rugged high

More information

PRODUCT PROFILE FEATURES

PRODUCT PROFILE FEATURES PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER

More information

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau KA 180F/00/en/06.01 (a) 52010984 Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau Safety instructions The FTS 20 floating switch may only be used as a level limit switch

More information

Digital Pressure Measuring Instrument MDR480

Digital Pressure Measuring Instrument MDR480 Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm

More information

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual

More information

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution

More information

Rosemount 751 Field Signal Indicator

Rosemount 751 Field Signal Indicator Rosemount 751 Field Signal Indicator Product Data Sheet August 2014 00813-0100-4378, Rev FA Available with an LCD display or analog meter Compact, rugged, and designed for industrial environments Available

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

T0118 T2118 T3118. Instruction Manual

T0118 T2118 T3118. Instruction Manual Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

Digital display DA 48

Digital display DA 48 Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital

More information

TEIP11 I/P signal converter for standard signals. Measurement made easy

TEIP11 I/P signal converter for standard signals. Measurement made easy Data Sheet 10/18-0.11-EN Rev. B TEIP11 I/P signal converter for standard signals Measurement made easy Current in air pressure Proven and reliable concept Compact design Small dimensions, low weight Sturdy

More information

Model 3051 Pressure Transmitter with HART Protocol

Model 3051 Pressure Transmitter with HART Protocol Model 3051 Pressure Transmitter with HART Protocol Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Configure

More information

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure

More information

330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring 330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring Description The standard 330400 Accelerometer has a limited temperature range it can be exposed to, due to its signal

More information

98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC.

98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC. 81471067 Electric Monitor Motor Control Panel For use with Model 8394059 SPIT-FIRE Monitor Installation, Operation, and Maintenance Instructions FOR ATEX APPLICATIONS 1302 WEST BEARDSLEY AVENUE P.O. BOX

More information

SITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI 01 2010

SITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI 01 2010 Overview are designed for measuring the flow of electrically conductive mediums. The full program consists of three different types of flowmeters making Siemens unique in that it covers all possible applications

More information

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications 077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing

More information

Instruction Manual Differential Pressure Transmitter

Instruction Manual Differential Pressure Transmitter DE28 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

API Marine. BMS Presentation. Ballast Measurement Systems

API Marine. BMS Presentation. Ballast Measurement Systems API Marine BMS Presentation Ballast Measurement Systems BMS4 Typical Configuration BMS4 Typical Configuration BMS4 Extended Configuration BMS4 System (24 tanks) Air regulator Terminal block Drain/Air Filter

More information

Toroidal Conductivity Sensor

Toroidal Conductivity Sensor Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:

More information

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity

More information

Flow switches Series AD/VH

Flow switches Series AD/VH Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

SEISMIC VELOCITY TRANSDUCER T1-40

SEISMIC VELOCITY TRANSDUCER T1-40 SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute

More information

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment

More information

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:

More information

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

Control and Distribution Boxes made of Stainless Steel Series 8150

Control and Distribution Boxes made of Stainless Steel Series 8150 www.stahl.de > Circumferential protection channel prevents water entry > Extended temperature range due to high-quality seal s > Optionally with hinges / cam locks or screw-on cover > Hinge versions with

More information

Micro Motion Model D and DL Coriolis Flow and Density Meters

Micro Motion Model D and DL Coriolis Flow and Density Meters Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,

More information

Rotary actuators Rotary wing drives Series RAK. Brochure

Rotary actuators Rotary wing drives Series RAK. Brochure Brochure 2 Rotary wing drives, angle of rotation: 30-270 Rotary wing drive, double-acting axis geometry: single 4 Rotary wing drives, angle of rotation: 90-270 Rotary wing drive, double-acting axis geometry:

More information

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Instruction Manual. T3111 T3111L T3111P T3111Ex

Instruction Manual. T3111 T3111L T3111P T3111Ex www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs

More information

Siemens AG 2016. 3/18 SIWAREX WL230 BB-S SA 3/18 Load cell 3/20 Base plate with overload protection 3/21 Elastomer bearing 3/22 Compact mounting unit

Siemens AG 2016. 3/18 SIWAREX WL230 BB-S SA 3/18 Load cell 3/20 Base plate with overload protection 3/21 Elastomer bearing 3/22 Compact mounting unit Siemens AG 2016 /2 Introduction /9 SIWAREX WL260 SP-S AA /9 Load cell /10 SIWAREX WL260 SP-S AB /10 Load cell /11 SIWAREX WL260 SP-S AE /11 Load cell /12 SIWAREX WL260 SP-S SA /12 Load cell /1 SIWAREX

More information

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200

More information

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B2325-1.0 en

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B2325-1.0 en HLC B1... HLC F1... HLC A1... HLC B1... HLC F1... Load cells Special features -- Hermetically sealed (IP68) -- Max. capacities: 220 kg... 10 t -- Stainless steel -- Low overall height -- Meets EMC/ESD

More information

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107 Supplementary instructions Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family Document ID: 4107 Contents Contents 1 For your safety 1.1 Appropriate use...

More information