Hydraulic integrated circuits

Size: px
Start display at page:

Download "Hydraulic integrated circuits"

Transcription

1 Hydraulic integrated circuits

2 WARNING! Variations and modifications of technical features and dimensions are reserved. WALVOIL S.p.A. also reserves the right to stop production of each and any model listed in the catalogue with no notice. Copyrights on the text contained herein belong to WALVOIL S.p.A.. Partial and full reproductions or copies of this catalogue are forbidden. WALVOIL IS NOT RESPONSIBLE FOR ANY DAMAGE CAUSED BY AN INCORRECT USE OF THE PRODUCT. 1 st EDITION MAY 2010

3 HYDRAULIC INTEGRATED CIRCUITS General Information Fluid:best use mineral oil with viscosity ranging between 10 and 200 cst. Filter:dirty oil is the main reason for failure and troubles of hydraulic parts and systems. The table below contains OLEOSTAR S.p.A. recommendations about the minimum oil contamination level according to individual specifications of different items. For further safety of your hydraulic equipment and of all valves assembled on it, we either recommend use suction filters (rather than return filters) or separated filter lines. TYPE OF EQUIPMENT - TYPE OF VALVE - Heavy duty equipment - Equipment running at bar ( psi) working pressure - Equipment using proportional controls - Equipment with high frequency cycles - Equipment running up to 210 bar (3050 psi) working pressure - Spool-type valves - Valves with calibrated ports - Equipment running at low working pressure - Pilot plants and equipment - Equipment with low frequency cycles CONTAMINATION LEVEL According to ISO /16/13 -/18/14 -/19/15 Installation:make sure to provide suitable gasket lubrication with clean oil before screwing the cartridge on the valve body. Also make sure to screw the cartridge manually in to reach against the gaskets in the valve body. Material:internal components made out of high grade steel duly treated and fabricated. For more information please ask our technical office. Working temperature:min. -25 C (-13 F) max. 90 C (194 F) with standard BUNA N seals. min. -20 C (-4 F) max. 200 C (392 F) with optional VITON seals. Rating diagrams:all rating diagrams of this catalogue are measured with mineral oil of 46 cst viscosity at 40 (104 F) temperature. All drawings dimensions are defined as mm in

4 HYDRAULIC INTEGRATED CIRCUITS Index Hydraulic diagram Type Description Maximum flow up to Maximum pressure Page VE/B/VMP/VUI/SR 14 (38 VP) Control valves for single acting cylinders l/min 20 US gpm 5.3 bar 210 psi Hydraulic diagram Type Description Maximum flow up to Maximum pressure Page VE/B/VMP/VUI/SR... Control valves for single acting cylinders l/min 150 US gpm 40 bar 350 psi

5 ACCESSORIES Indice Index Coils Introduction...page 13 Coil BE...page 14 Coil BT... page 15 Solenoid Connectors Introduction, solenoid connectors CC-CA, CL and CP... page 16 5

6 6

7 CONTROL VALVES FOR SINGLE ACTING CYLINDERS Series VE/B/VMP/VUI/SR 14 (38 VP) Operation This valve allows performance at all functions required by lifting systems using single acting cylinders. Performance Body Valves Tipo Maximum flow Maximum pressure Weight Coils* Oil leak from C to T l/min US gpm bar kg lb VE/B/VMP/VUI/SR 14 (38 VP) psi- BE see page 12 0,25 cm 3 /min -15x10-3 in 3 /min- (5 drops) at 210 bar psi- 1,27 (alum.) 2,65 (steel) 2,80 (alum.) 5,84 (steel) *Warning: BE RAC solenoids and special connector should be strictly used with the NA version powered by AC current 7

8 Tipo VE/B/VMP/VUI/SR 14 (38 VP) Type VE/B/VMP/VUI/SR 14 (38 VP) Control valves for single acting cylinders Dimensions and hydraulic circuit Rating diagrams Pressure drop diagram (US gpm) (psi) Order code VE /B /VMP /VUI /SR VP / / / Assembly scheme NA) Normally opened NC) Normally closed Pressure settings (bar) TB) TV) TS) TR) 5 40 ( psi) 20 80( psi) ( psi) ( psi) Body material _ Aluminium acsteel

9 CONTROL VALVES FOR SINGLE ACTING CYLINDERS Series VE/B/VMP/VUI/SR... Operation This valve allows performance at all functions required by lifting systems using single acting cylinders. Performance Body Valves Type VE/B/VMP/VUI/SR VE/B/VMP/VUI/SR VE/B/VMP/VUI/SR VE/B/VMP/VUI/SR Maximum flow Maximum pressure Weight Coils* Oil leak from C to T l/min US gpm bar kg lb psi- (aluminium body) psi- (steel body) BT see page 13 0,25 cm 3 /min -15x10-3 in 3 /min- (5 drops) at 210 bar psi- 1,27 (alum.) 2,65 (steel) 2,73 (alum.) 3,19 (steel) 4,65 (alum.) 10,03 (steel) *Warning:BT RAC solenoids and special connector should be strictly used with the NA version powered by AC current 2,80 (alum.) 5,84 (steel) 6,02 (alum.) 7,03 (steel) 10,25 (alum.) 22,11 (steel) 9

10 Type VE/B/VMP/VUI/SR 38 Control valves for single acting cylinders Dimensions and hydraulic circuit Rating diagrams Pressure drop diagram 3 6 9(US gpm) (psi) Order code VE /B /VMP /VUI /SR 38 / / / Assembly scheme Pressure settings (bar) Body material NA) Normally opened NC) Normally closed TB) 5 40( psi) _ Aluminium TV) 20 80( psi) acsteel TS) ( psi) TR) ( psi) 10

11 Control valves for single acting cylinders Type VE/B/VMP/VUI/SR 12 (34) Dimensions and hydraulic circuit Rating diagrams Pressure drop diagram Pressure drop diagram (US gpm) (US gpm) (psi) 100 (psi) Order code VE /B /VMP /VUI /SR / / / / Port size 12 G 1/2 34 G 3/4 Assembly scheme NA) Normally opened NC) Normally closed Pressure Body material settings(bar) _ Aluminium TB) 5 40 ( psi) acsteel TV) ( psi) TS) ( psi) TR) ( psi) 11

12 Type VE/B/VMP/VUI/SR 100 Control valves for single acting cylinders Dimensions and hydraulic circuit Rating diagrams Pressure drop diagram (US gpm) 200 (psi) Order code VE /B /VMP /VUI /SR 100 / / / Assembly scheme NA) Normally opened NC) Normally closed Pressure settings(bar) TB) 5 40 ( psi) TV) ( psi) TS) ( psi) TR) ( psi) Body material _ Aluminium acsteel 12

13 ELECTRIC COILS FOR TUBES Coils BE and BT Operation Multiple coil versions are available to allow use with direct and alternated current. Thermal insulation class: F (Tmax = 155 C-303 F-) (VDE 0580) Relative duty cycle: ED 100% (VDE 0580) To assure ED = 100% and perform continuous coil operation, the following conditions should be met: TA + T < Tmax Whereas: -TA = ambient temperature - T = temperature increase due to operation -Tmax = maximum admissible temperature according to insulation class We therefore recommend always checking that the maximum ambient temperature is same as Tmax - T (providing no special operating requirement are there). Safety standards (DIN 40050):IP54 without connector IP65 with connector Admissible voltage range for long lasting and trouble free operations life: nominal voltage ±10% Performance Resistance Ω Current (A) Power (W) or (VA) T Type T A =20 C 68 F Cold Warm Cold After 1 hour at: -Ta=20-25 C F -Nominal voltage BE 12 Vcc 7,7 1,56 1,16 18,7 W BE 24 Vcc 31 0,77 0,58 18,6 W BE 48 Vcc 116 0,41 0,3 19,8 W BE 110 Vcc 700 0,157 0,12 17,3 W BE 24 Vca (50 Hz) 5,3 1,16 0,87 28 VA BE 48 Vca (50 Hz) 21,3 0,6 0,45 28,8 VA BE 110 Vca (50 Hz) 108 0,26 0,19 28,6 VA BE 220 Vca (50 Hz) 438 0,13 0,09 28,6 VA BE 380 Vca (50 Hz) ,09 0,06 34,2 VA BE 24 RAC 27 0,8 0,6 17,3 W BE 110 RAC 630 0,157 0,12 15,6 W BE 220 RAC ,08 0,06 15,7 W BT 12 Vcc 6,8 1,77 1,15 21 W - - BT 24 Vcc 27 0,89 0,58 21 W - - BT 48 Vcc 110 0,43 0,32 20,3 W BT 110 Vcc 700 0,15 0,11 15,7 W BT 24 Vca (50 Hz) 4,2 0,94 0,83 22,6 VA - - BT 48 Vca (50 Hz) 15,3 0,73 0,54 35 VA BT 110 Vca (50 Hz) 89 0,21 0,18 23,1 VA - - BT 220 Vca (50 Hz) 350 0,1 0,08 22 VA - - BT 24 RAC 90 0,47 0,37 20,7 W BT 110 RAC 540 0,2 0,16 21,6 W BT 220 RAC ,1 0,08 21,7 W (C ) (F ) 13

14 Coil BE Electric coils for tube diameter 13 mm (0.51 in) Dimensions Ø Ø Order code Type Ordering code Ordering code with standard connector BE 12 Vcc 4SL SL BE 24 Vcc 4SL SL BE 48 Vcc 4SL SL BE 110 Vcc 4SL SL BE 24 Vca (50 Hz) 4SL SL BE 48 Vca (50 Hz) 4SL SL BE 110 Vca (50 Hz) 4SL SL BE 220 Vca (50 Hz) 4SL SL BE 380 Vca (50 Hz) 4SL SL Standard connector code 4CN Connector page Page 16 (CC-CA) BE 24 RAC 4SL SL CN BE 110 RAC 4SL SL CN BE 220 RAC 4SL SL CN Page 16 (CL) 14

15 Electric coils for tube diameter 14 mm (0.55 in) Coil BT Bobina BT Dimensions Ø 0.55 Ø Order code Type Ordering code Ordering code with standard connector BT 12 Vcc 4SL SL BT 24 Vcc 4SL SL BT 48 Vcc 4SL SL BT 110 Vcc 4SL SL BT 24 Vca (50 Hz) 4SL SL BT 48 Vca (50 Hz) 4SL SL BT 110 Vca (50 Hz) 4SL SL BT 220 Vca (50 Hz) 4SL SL Standard connector code 4CN Connector page Page 16 (CC-CA) BT 24 RAC 4SL SL CN BT 48 RAC 4SL SL CN BT 110 RAC 4SL SL CN Page 16 (CP) BT 220 RAC 4SL SL CN

16 Solenoid connectors CC-CA, CL and CP CONNECTORS Operation There are 3 types of different solenoid connectors: CC-CA 2-poles + GROUND electric connectors in compliance with DIN and A/ISO standards and Electric connectors suitable for connection of DC and AC current coils. Type of current must be same as for the coil used. CL 2-poles + rectifier + GROUND electric connectors in compliance with DIN and A/ISO standards and Electric connectors suitable for connection of DC current coils BE RAC. AC current operation only. Use of these poles depends on the type of valve used. CP 2-poles + rectifier + GROUND electric connectors in compliance with DIN and A/ISO standards and Electric connectors suitable for connection of DC current coils BT RAC. AC current operation only. Use of these poles depends on the type of valve used. Type CC-CA CL CP Nominal voltage AC max 250 V DC max 300 V Maximum capacity of in-built diode - 1 A 3 A Nominal poles voltage Max poles voltage 10 A 16 A Poles resistance 4 m Ohm Max poles section Cable size options 1,5 mm in 2 Pg09 Cable diameter 6-8 mm in Safety standards IP65 (DIN 40050) Insulation index VDE0110-1/ Order code: CC-CA Connector ø Order code: CL Connector ø Order code: CP Connector ø

17 Notes Note 17

18 Notes 18

19 Notes 19

20 1 st edition May

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control

More information

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow 2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description

More information

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51 83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

SOLENOID VALVES 3-4 WAY

SOLENOID VALVES 3-4 WAY SOLENOID VLVES - WY IE/C// CT: FP/VCR Page: 7 SHEET: / SOLENOID VLVES - - WY CV SOLENOID VLVES -WY/-POSITION /- UNF.7 5.7 The electric valve is a -way -position directional electrically controlled Slight

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007 Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30 85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08

More information

G1/4 Q8. Standard with biased position

G1/4 Q8. Standard with biased position Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,

More information

Coils - Connectors. Coils Connectors. Summary. RE 18325-90/12.10 1/10 Replaces: RE 18325-90/02.10. Description

Coils - Connectors. Coils Connectors. Summary. RE 18325-90/12.10 1/10 Replaces: RE 18325-90/02.10. Description RE 18325-90/12.10 1/10 Replaces: RE 18325-90/02.10 Coils Connectors Summary Description Page Description Page Coils Coil S8-356 - CLASS H - 20 W 2-3 Coil S8-356 - CLASS H - 17 W 4 Coil S5 - CLASS H 5 Coil

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

15/40/80CN Series Medium Pressure Filters

15/40/80CN Series Medium Pressure Filters 1/4/8CN Series Medium Pressure Filters Max 32 l/min - 7 bar Global Filtration Technology 1/4/8CN Series TYPICAL APPLICATIONS Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard)

More information

3/2 Solenoid Cartridge Valve, Size 6

3/2 Solenoid Cartridge Valve, Size 6 / Solenoid Cartridge Valve, Size 6 Q max = l/min, p max = 5 bar Bidirectional seat-valve shut-off, direct acting Guided valve spool and poppet Two spool variants are available Available in two mounting

More information

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

type V46, solenoid or pneumatic operated

type V46, solenoid or pneumatic operated SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function

More information

Solenoid valves 2/2-way direct-operated Type EV210A

Solenoid valves 2/2-way direct-operated Type EV210A Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the

More information

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional

More information

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. D e s c r i p t i o n 500 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. A major feature of these

More information

DSE5J 83 280/112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05)

DSE5J 83 280/112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05) 83 280/112 ED DSE5J DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05) p max 320 bar Q max 180 l/min MOUNTING SURFACE OPERATING

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

SOLENOID VALVE FOR REFRIGERATING SYSTEMS

SOLENOID VALVE FOR REFRIGERATING SYSTEMS SOLENOID VALVE FOR REFRIGERATING SYSTEMS FROM UALITY OUR NATURAL DEVELOPMENT Achieved the goal of fi fty years working in the industry of Refrigeration and Air Conditioning, Castel uality Range of Products

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

servo-controlled 3-WaY vacuum solenoid valves WiTH

servo-controlled 3-WaY vacuum solenoid valves WiTH servo-controlled 3-WaY vacuum solenoid s WiTH low absorption electric coil The 3-way vacuum solenoid s in this series feature two positions with pneumatically pilot-operated conical shutters. They can

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage Safety for Hydraulics Leak free double check valve, pilot operated, series Cartridge type, two stage 8 1 1 General description spring closed, pilot operated, cartridge type poppet valve it holds the load

More information

Coils - Connectors. Coils Connectors. Summary. RE 18325-90/03.16 Replaces: RE 18325-90/07.15. Description

Coils - Connectors. Coils Connectors. Summary. RE 18325-90/03.16 Replaces: RE 18325-90/07.15. Description 1/22 Replaces: RE 18325-90/07.15 Coils Connectors Summary Description Page Description Page Coils Coil S8-356 - CLASS H - 20 W 2-3 Coil S8-356 - CLASS H - 17 W 4 Coil S8-356 - CLASS H - 17 W - LISTED UL

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

PRE3G 81 250/212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

PRE3G 81 250/212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12 81 250/212 ED PRE3G PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS SUBPLATE MOUNTING ISO 4401-03 (CETOP 03) p max 350 bar Q max 40 l/min MOUNTING SURFACE OPERATING

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Shuttle valves SSR -2 Check valves, direct operated RK / R CS SPZE SPV

More information

Directional seated valves type VP 1

Directional seated valves type VP 1 Directional seated valves type VP 1 zero leakage, intended for general hydraulic applications and grease lubing systems Flow Q max Operation pressure p max = 15 lpm = 400 bar Individual valve Individual

More information

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05 D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05 GENERAL SECTION PAGE MOOG SERVO- AND PROPORTIONAL CONTROL VALVES General 2 enefits and Functionality 3 General

More information

Compact power modules

Compact power modules Compact power modules Replaces: 07.12 1/22 DL series Summary Description Page Ordering details 2 echnical data 4 A.C. Electric motors 9 Central manifolds 11 Flow restrictor 16 Coils and connector 16 Gear

More information

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage Safety for Hydraulics Leak free check valve, pilot operated, series Cartridge type, two stage prevents a load from falling if a burst occurs in feed pipe hardened seat and poppet prevents creep of hydraulically

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Sporlan V-Series Ruby Seat Solenoid Valves

Sporlan V-Series Ruby Seat Solenoid Valves aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Sporlan V-Series Ruby Seat Solenoid Valves RACE Catalogue 30-10-8 UK,

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999 CONTAMINATION CONTROL in hydraulic systems in the hydraulic system is a very wide and complex matter; the following is just a short summary. Our Customer Service is at your disposal for any further information.

More information

3/2-way Mini Solenoid Valve

3/2-way Mini Solenoid Valve 3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug

More information

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits. Vickers Pressure Relief Pressure Relief and Sequence Valves CG2V-6/8, 1 Series; CG5V-6/8, 2 Series Typical Section CG2V-6*W-1 relief valve Basic Characteristics Maximum pressure.......... 35 bar (5 psi)

More information

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications VARIABLE DISPLACEMENT AXIAL PISTON PUMPS For truck applications TVP FEATURES Variable displacement axial piston pumps swash plate design ideally suited for open circuit truck applications. The compact

More information

MANTA Piston Distributor for Oil and Fluid Grease

MANTA Piston Distributor for Oil and Fluid Grease MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube

More information

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 OVERVIEW D660 Section Page MOOG SERVO-PROPORTIONAL CONTROL VALVES Overview 2 3 Technical Data 4 5 Electronics

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

OLI. Oil level indicator

OLI. Oil level indicator OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

Return line filters. Return line filters

Return line filters. Return line filters Return line filters Return line filters Index Technical data - 5 Filters series 6 Filters series --3 8 ccessories Spare parts Uni-ardan Italia S.p.. reserves the right to make technical changes to the

More information

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS 2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

Line-Mounted Valves L Series

Line-Mounted Valves L Series Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free

More information

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SF-2C-115A-35 S-1AY-12D-35 SD-2C-12D-35 Features High Flow/ High Pressure: Up to 40 gpm / 5000 psi working pressure*.

More information

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SD-2B-115A-35 SDS-2H-12D-35 S-2B-115A-35 Features High Flow/ High Pressure: Up to 25 gpm / 5000 psi working

More information

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)

More information

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100 CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL

More information

Steering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Steering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min Steering unit RE 11872/05.06 /10 Type LAGL Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min H7375 Table of contents Contents Page Features 1 Ordering code 2 Function, section 3 Device

More information

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type...

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

ORLANDO srl. M P R 50 025 OPTIMA Radial pressure gauges for swimming-pools 0-2,5 Bar

ORLANDO srl. M P R 50 025 OPTIMA Radial pressure gauges for swimming-pools 0-2,5 Bar Chiavari (Ge) - Italia Tel.: Italia + 0185 + 38.50.10 Fax: Italia + 0185 + 38.50.11 e-mail: orlando@orlando.it Http://www.orlando.it M R 50...: Radial pressure gauge ø 50 ( available scale in bar: 4, 6,10,12,16

More information

Solenoid valves Type EVU

Solenoid valves Type EVU Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot

More information

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking

More information

STC 3S012-020-A Series Solenoid Valves

STC 3S012-020-A Series Solenoid Valves STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB.. 1.1 Generals. 1.2 Application examples. 2.2 3-way flow control. 2.1 2-way flow control

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB.. 1.1 Generals. 1.2 Application examples. 2.2 3-way flow control. 2.1 2-way flow control Flow Control Valve Series SRCB.. plug-in solenoid for easy coil change flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports energy - optimised

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

ISO 15407-1/2 (VDMA 24563) ISO 02 (18 mm) - ISO 01 (26 mm) Valves

ISO 15407-1/2 (VDMA 24563) ISO 02 (18 mm) - ISO 01 (26 mm) Valves BD ISO 0/ (VDM ) ISO 0 ( mm) ISO 0 ( mm) Valves BDE = solenoid valves ISO 0/ with integrated connection including V DC coils and connector BDB = solenoid valves ISO 0/ with external connection with M connector

More information

SAFETY BLOCK type BS 9.3 E 01-12

SAFETY BLOCK type BS 9.3 E 01-12 SAFETY BLOCK type BS 9.3 E 01-12 9.3.1 TECHNICAL DATA MAX OPERATING PRESSURE (PS): 420 bar PRESSURE TEST (PT): 1.43 x PS NOMINAL PASSAGE DIAMETER: 10mm, 20mm, 25mm, 32mm WORKING TEMPERATURE: -40 +150 FLUID

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

Typical Aluminum GFM Mass Flow Meter

Typical Aluminum GFM Mass Flow Meter MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.

More information

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7 Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: sales@hydronit.com Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Denotes New Winner s Circle Product Line. Catalog HY15-3502/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY

Denotes New Winner s Circle Product Line. Catalog HY15-3502/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY Catalog HY-5/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI HIGH FLOW VALVE FAMILY See individual catalog pages for exact specifications. WAY SPOOL TYPE GS *... X / C9-.. Position,

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

SERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a

SERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a SRIS FRI Maximum working pressure bar Flow rate to 1 l/min s.p.a R FRI series filter has been disigned and developed to satisfy the demands pf applications, on return or low preessure line in Hydraulic

More information

Seat Valves. 1 Description. Series SVH04. 1.1 Technical data. 1.2 Performance graphs

Seat Valves. 1 Description. Series SVH04. 1.1 Technical data. 1.2 Performance graphs Seat Valves Series SVH0 ctuators are shut-off with virtually zero-leakage, even over a longer period of time Particularly suitable for mobile machines, thanks to the low-weight design and small dimensions

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

3/2-way pneumatic cartridge solenoid valve

3/2-way pneumatic cartridge solenoid valve 3/2-way pneumatic cartridge solenoid valve Compact design with 11 mm width per station Orifices from 0.5 mm (9 bar) to 1.2 mm (1.5 bar) High durability and reliability Low power consumption, as well as

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

Model 1210C Battery Powered Pump Shown. Description

Model 1210C Battery Powered Pump Shown. Description 12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with

More information

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4 SPOO & SV VAVS monostable / bistable function threaded ports -G 1/ 5/-5/3 Series 1 FATURS Reliability: steel spool & sleeve technology with long service life Robust valve design, particularly recommended

More information

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting Female NPT Thread 3/8 OD Tube 3/8 Push-In Fitting 2P050 Series Solenoid Valve Specifications Valve Model 2P050-1/4 2P050-3/8

More information

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type... 5/132...

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information