2 With expertise, and a comprehensive portfolio of products and life-cycle services, we help value-minded industrial customers improve their energy efficiency and productivity. General purpose - single phase motors, ODP TENV & TEFC kw ( hp) ODP kw ( hp) 110/220 VAC Standard, C-face - with and without base, D-flange General purpose - three phase motors, ODP TENV & TEFC ,100 kw (0.12-1,500 hp) ODP ,100 kw (0.25-1,500 hp) 200, 230/360, 380, 400, 460, 575 VAC Standard, C-face - with and without base, D-flange Large AC induction motors TEFC, TEAAC, TEWAC, ODP, WPI, WPII ,900 kw (500-20,000 hp) Low ( VAC) Medium voltage (to 6,900 VAC) High voltage (to 13.2 kvac) 50 and 60 Hz Vertical and Horizontal Standards NEMA, CSA, BS, ANSI, API 541, API 547 Certifications UL, CSA, hazardous area, ABS (marine) 2 ABB Motors and Generators Baldor Reliance NEMA motors product overview

3 Severe duty motors Certifications ,250 kw (0.5-3,000 hp) 200, 230/460, 380, 460, 575, 690, 2,300, 3,300, 4,000, 6,600, 11,500 VAC Standard, C-face - with and without base, D-flange Division 2, Class I, Groups A, B, C & D Inverter Duty on Severe Duty and IEEE841 motors NEMA design A & B Severe Duty motors IP55 IEEE Dirty duty; crusher and quarry duty high torque design motors Design D (High Slip) oil field pump motors Explosion proof motors Service Factor Certifications kw ( hp) 115/230, 200, 230/460, , 575 VAC Standard, C-face - with and without base, D-flange 1.0, 1.15 S.F. Zone 1, Division 2, Class I & Class II ATEX and IEC Ex available Washdown duty motors kw ( hp) 200, 230/460, 380, 460, 575 VAC Standard, C-face - with and without base White washdown, paint-free, stainless and SSE encapsulated stainless, feather picker motors ABB Motors and Generators Baldor Reliance NEMA motors product overview 3

4 Pump motors TEFC, ODP TEFC kw (1-50 hp) ODP kw (1-75 hp) 115/230, 200, 230/460, 380, 460, 575, 2,300/4,000 VAC 50 Hz and 50/60 Hz available JM, JP and West Coast mounting, SAE hydraulic pump Jet pump 56J through 2.2 kw (3 hp) Submersible kw (1-450 hp) Immersible kw (5-250 hp) Vertical solid shaft, low, medium, and high thrust API 610 up to 670 kw (900 hp) HVAC motors, ODP, TEAO TENV & TEFC kw (1-50 hp) ODP kw (1-100 hp) TEAO kw (3-100 hp) 115/230, 200, 230/460, 380, 460, 575 VAC Standard, Resilient mount Shaft grounding for use with adjustable speed drives Direct drive cooling tower motor Speed TEAO kw ( hp) Custom voltage available ( VAC) RPM Direct drive, eliminating CT gearbox Requires ABB ACS880+N5350 drive High efficiency interior permanent magnet design 4 ABB Motors and Generators Baldor Reliance NEMA motors product overview

5 Definite purpose motors TEFC, ODP Two-speed motors kw ( hp) Pressure washer motors kw (1.5-5 hp) 50 Hz and 50/60 Hz available Arbor saw, woodworking, pre-1952-nema, U-frame, automotive duty, synchronous permanent magnet motors Stator and rotor sets, partial motors Unit handling and conveyor motors TEFC kw ( hp) 115/230, 200, 230/460, 460, 575 VAC Standard, C-Face with or without base, D-flange Brake motors Brake TEFC, ODP TEFC kw ( hp) ODP kw ( hp) 115/230, 200, 230/460, 380, 460, 575 VAC 4-1,360 Nm (3-1,000 lb-ft) Explosion proof and washdown motors ABB Motors and Generators Baldor Reliance NEMA motors product overview 5

6 Inverter / vector motors Feedback TENV, TEBC & TEFC ,120 kw (0.33-1,500 hp) 230/460, 575 VAC Inverter/Vector - 50/60 hz, VS Master has to be run with a drive With or without encoder or tach Washdown, explosion proof, inverter duty motors 1000:1 constant torque Inverter / vector motors Feedback, TEBC, DPFV TENV kw (2-100 hp) TEFC kw ( hp) TEBC kw (5-500 hp) DPFV kw (5-1,200 hp) 230, 380, 400, 415, 460, 575, up to 1,000 VAC Variable frequency has to be run with a drive With or without encoder or tach Custom NEMA and IEC motors available Induction 1000:1 or Interior permanent magnet, constant torque DC motors - Permanent magnet kw ( hp) 12, 24, 90, 180 VDC NEMA or IEC mounting available C-face with base, rigid base General purpose, integral tachometer, explosion proof, washdown, stock and custom designs 6 ABB Motors and Generators Baldor Reliance NEMA motors product overview

7 DC motors - wound field Fractional Integral kw ( hp) 90, 180 VDC for 1 Ph control NEMA C-Face with base, rigid base General purpose, explosion proof DPFG, DPBV,, TEDC, kw kw (1-3,000 hp) 27-1,300 kw (35-1,750 hp) IEC laminated frame 90, 180 VDC for 1 Ph control, 240, 500, 700 VDC for 3 Ph control NEMA or IEC available General purpose, explosion proof, round frame, laminated steel frame Gearmotors Gearhead Type Power Supply Feedback Right Angle & Parallel Shaft AC, DC AC /460 VAC DC 12, 24, 90, 180 VDC With or without encoder or tach Washdown, and Inverter Duty Motor accessories & NEMA motor Mod-Express Bases Housing Mod-Express C-face, D-flange kits, double C-face brake kits Adjustable motor bases and conversion bases (T-frame to U-frame) Fan housing, drip covers, conduit box kits Menden, Germany Build Center Fort Smith, Arkansas Gainesville, Georgia ABB Motors and Generators Baldor Reliance NEMA motors product overview 7

8 Contact us We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB Ltd does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained herein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in part - is forbidden without prior written consent of ABB Ltd. 9AKK EN Copyright 2012 ABB. All rights reserved. Specifications subject to change without notice.

BALDOR ELECTRIC COMPANY PRODUCT OVERVIEW

BALDOR ELECTRIC COMPANY PRODUCT OVERVIEW BALDOR ELECTRIC COMPANY PRODUCT OVERVIEW Small Motor Rule Motors Compliant with DOE Small Motor Rule 2010 Single Phase, Open Drip Proof ¼ - 3 HP (0.19 1.49 kw) Three Phase, Open Drip Proof ¼ - 3 HP (0.19

More information

Baldor Electric Company PRODUCT OVERVIEW

Baldor Electric Company PRODUCT OVERVIEW Baldor Electric Company PRODUCT OVERVIEW 2013 Motors Motor efficiency level available as needed for local efficiency regulations NEMA Premium (IE3) for U.S., Canada and Mexico 1-200 Hp (0.75-150 kw) Energy

More information

GE Energy. Motors Product Line

GE Energy. Motors Product Line GE Energy Motors Product Line Expect More We ve manufactured motors for over 125 years. In 1879, GE founder, Thomas Edison constructed the first electric motor ever made for a 110 to 120 Volt line at Menlo

More information

The Energy Independence and Security Act of 2007. The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010

The Energy Independence and Security Act of 2007. The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010 The Energy Independence and Security Act of 2007 The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010 January 23, 2009 To Our Customers, Baldor Electric Company 5711 R.S.

More information

Product Brochure. Certified Mining Motors

Product Brochure. Certified Mining Motors Product Brochure Certified Mining Motors Profile Baldor Electric Company (a member of the ABB group) is a world leader in motors for the mining industry. In the continuous (24/7) operation of underground

More information

We will discuss common industrial applications with guides for the proper use of electric motors on these.

We will discuss common industrial applications with guides for the proper use of electric motors on these. INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which

More information

Product Brochure. Controlled start transmission

Product Brochure. Controlled start transmission Product Brochure Controlled start transmission What CST does The Dodge CST (Controlled Start Transmission) is a 2 in 1 gearbox which combines a planetary gear reducer with an integral wet clutch system.

More information

Motor Specifications. Nameplate

Motor Specifications. Nameplate Motor Specifications Nameplate The nameplate of a motor provides important information necessary for selection and application. The following drawing illustrates the nameplate of a sample 30 horsepower

More information

Why Baldor? Table of Contents. www.baldor.com

Why Baldor? Table of Contents. www.baldor.com Pump Motors Why Baldor? Industry s shortest lead times/flexible manufacturing. Baldor has the industry s shortest lead times on custom motors just ten working days. Our unique LEAN FLEX FLOW manufacturing

More information

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP ABB The Preferred Partner Egypt Cement Corporation, a major cement manufacturer, has chosen ABB wound rotor motors for all key applications

More information

Baldor Electric Position on DOE Small Motor Rule

Baldor Electric Position on DOE Small Motor Rule Baldor Electric Position on DOE Small Motor Rule WP0035 WP0034 Page 1 of 6 US Integral DOE Small HP Motor Rule Rule Baldor Electric Position on DOE Small Motor Rule 10/28/14 On March 9, 2010 the US Department

More information

GE Power Conversion. Motors. Medium / High Voltage and High Speed 190 to 100,000 kw 250 to 134,000 HP

GE Power Conversion. Motors. Medium / High Voltage and High Speed 190 to 100,000 kw 250 to 134,000 HP GE Power Conversion Motors Medium / High Voltage and High Speed 190 to 100,000 kw 250 to 134,000 HP 2 GE I Power Conversion GE has been setting the standard in manufacturing motors for over 125 years.

More information

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION SC ELECTROPUTERE SA SC ELECTROPUTERE SA 1. Vision, Mission, Values SC ELECTROPUTERE SA 2. LOCATION Craiova: Located in the South West of the country,

More information

Application Information

Application Information AGENCY LISTINGS UL and CSA Marathon Electric s Fire Pump and Explosion Proof motors are UL Listed. Other motor types are UL Recognized, including models with inherent overheating protection as noted (i.e.

More information

Brochure. ABB Customer Training Program for Motors and Generators Sharing knowledge and creating value

Brochure. ABB Customer Training Program for Motors and Generators Sharing knowledge and creating value Brochure ABB Customer Training Program for Motors and Generators Sharing knowledge and creating value With expertise, and a comprehensive portfolio of products and life-cycle services, we help value-minded

More information

Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors

Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors C-Face Kits for Field Conversion NEMA AC s Features: Complete kits with all hardware necessary for converting Baldor 56 though 449T frame ridgid base motors to C-Face mounting with base. For Baldor conversion,

More information

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles AC Induction Motors Simplest and most rugged electric motor Consists of wound stator and rotor assembly AC in the primary member (stator) induces current in the secondary member (rotor) Combined electromagnetic

More information

Brochure. Global MEPS Energy efficiency regulations for low voltage motors around the world. ABB Title Lorem Ipsum dolor sit Possible Subtitle

Brochure. Global MEPS Energy efficiency regulations for low voltage motors around the world. ABB Title Lorem Ipsum dolor sit Possible Subtitle Brochure Global MEPS Energy regulations for low motors around the world ABB Title Lorem Ipsum dolor sit Possible Subtitle ABB s broad range covers all MEPS across the globe Electric motors are so useful

More information

General Information. ME-business can be accessed through: www. marathonelectric.com.

General Information. ME-business can be accessed through: www. marathonelectric.com. MARATHON ELECTRIC Since 1913, Marathon Electric s name has been recognized for engineering excellence, custom-designed products and an extensive product line of industrial quality motors. Available in

More information

Direct Current Motors and Drives 1/50-3000 Hp

Direct Current Motors and Drives 1/50-3000 Hp Direct Current Motors and Drives 1/50-3000 Hp Why Baldor? 5% 12% 5% 78% Customer Preference BaldorReliance Competitor #1 Competitor #2 All Others The percentages shown indicate results of a 2012 survey

More information

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022

More information

AC Kinetics Variable Frequency Drive Comparative Transient Inertial Testing. This document was prepared by Advanced Energy.

AC Kinetics Variable Frequency Drive Comparative Transient Inertial Testing. This document was prepared by Advanced Energy. AC Kinetics Variable Frequency Drive Comparative Transient Inertial Testing This document was prepared by Advanced Energy. December 12 th, 2014 Introduction In June of this year, AC Kinetics contacted

More information

DC MOTORS NEMA FRAME SCR RATED

DC MOTORS NEMA FRAME SCR RATED NEMA FRAME SCR RATED NEMA FRAME MOTORS SCR RATED High voltage permanent magnet DC motors are typically used with an SCR (thyristor) controller in applications requiring adjustable speed and constant torque

More information

I hope you find them useful and I would appreciate any comments or thoughts you might have for future improvements, corrections or topics.

I hope you find them useful and I would appreciate any comments or thoughts you might have for future improvements, corrections or topics. COWERN PAPERS Baldor Electric Company 5711 R.S. Boreham Jr. Street Fort Smith, AR 72901 Phone (479) 646-4711 Fax (479) 648-5792 www.baldor.com Enclosed you will find a set of papers that I have written

More information

C Standard AC Motors

C Standard AC Motors C Standard AC Standard AC C-1 Overview, Product Series... C-2 Constant... C-9 C-21 C-113 Reversible C-147 Overview, Product Series Constant Reversible Electromagnetic Brake C-155 Electromagnetic Brake

More information

Technical Guide No. 100. High Performance Drives -- speed and torque regulation

Technical Guide No. 100. High Performance Drives -- speed and torque regulation Technical Guide No. 100 High Performance Drives -- speed and torque regulation Process Regulator Speed Regulator Torque Regulator Process Technical Guide: The illustrations, charts and examples given in

More information

Principles of Adjustable Frequency Drives

Principles of Adjustable Frequency Drives What is an Adjustable Frequency Drive? An adjustable frequency drive is a system for controlling the speed of an AC motor by controlling the frequency of the power supplied to the motor. A basic adjustable

More information

1/50-500 Horsepower Product Line DPG-FV, TEFC, TENV, XP, SPG enclosures Fractional DC DC PM SCR Round RPM III

1/50-500 Horsepower Product Line DPG-FV, TEFC, TENV, XP, SPG enclosures Fractional DC DC PM SCR Round RPM III DC & Controls Available in round frame and unique laminated square frames, Baldor Reliance DC motors offer performance and reliability in tough applications. Round frame DC motors utilize permanent magnet

More information

Documenting Results to Validate Energy Savings Projects: Case Study of Direct Drive Cooling Tower Installations: Before and After

Documenting Results to Validate Energy Savings Projects: Case Study of Direct Drive Cooling Tower Installations: Before and After Documenting Results to Validate Energy Savings Projects: Case Study of Direct Drive Cooling Tower Installations: Before and After Roman Wajda, Baldor Electric Company ABSTRACT Documenting the actual energy

More information

Brochure. Electric generators to power the world

Brochure. Electric generators to power the world Brochure Electric generators to power the world We provide motors and generators, services and expertise to save energy and improve customers processes over the total life cycle of our products, and beyond.

More information

What Do All Those Things on an AC Motor Nameplate Mean?

What Do All Those Things on an AC Motor Nameplate Mean? What Do All Those Things on an AC Motor Nameplate Mean? Introduction: Ever order a motor on power, speed, and enclosure? PO says maybe "5 hp, 1,800 rpm, TEFC." New-motor nameplate says "HP 5, RPM 1748,

More information

XRI Severe Duty 143-449T Frame. IEC Globetrotter 63-225M Frame

XRI Severe Duty 143-449T Frame. IEC Globetrotter 63-225M Frame XRI Severe Duty 143-449T Frame NEMA Premium /XRI - As a leading supplier of premium efficiency motors, we help conserve money and our environment. Marathon s designs are 100% compliant with CEE efficiency

More information

A Proven Approach to Reducing Electricity Costs

A Proven Approach to Reducing Electricity Costs A Proven Approach to Reducing Electricity Costs The Answer for an Energy Driven Economy First in Energy Efficiency Since 1920 The history of energy efficiency in industrial motors is really the story of

More information

Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications

Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications DC3 DC Drives Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications The Reliance Electric DC3 family of drives provides cost-effective variable speed control and operates

More information

Electronic, Digital and Mechanical Vibration Switches

Electronic, Digital and Mechanical Vibration Switches PT500 Electro-Mechanical Vibration Switch Introduction The PT500 is an economical solution that provides basic vibration protection for rotating reciprocating machines. The PT500 uses an inertia sensitive

More information

AC Induction Motor Slip What It Is And How To Minimize It

AC Induction Motor Slip What It Is And How To Minimize It AC Induction Motor Slip What It Is And How To Minimize It Mauri Peltola, ABB Oy, Helsinki, Finland The alternating current (AC) induction motor is often referred to as the workhorse of the industry because

More information

Fundamentals of Inverter Fed Motors

Fundamentals of Inverter Fed Motors Fundamentals of Inverter Fed Motors Technical Manual 10/02 MN780 Contents Page The Growing Use Of Inverters.................................................................. 1 How Inverters Affect Motors....................................................................

More information

ENERGY-SAVINg DRIVE PACKAGE DE ES FR IT. Overview

ENERGY-SAVINg DRIVE PACKAGE DE ES FR IT. Overview ENERGY-SAVINg DRIVE PACKAGE SPriPM Motor & YASKAWA V1000 Inverter Drive EN DE ES FR IT Overview - Super Premium IPM Motor & YASKAWA V1000 Inverter Drive The Motor-Inverter Package was developed to support

More information

Baldor Electric Company Premium Efficiency Motor Specification Totally Enclosed Fan Cooled Motor 1-250 HP Rev June 6, 2001

Baldor Electric Company Premium Efficiency Motor Specification Totally Enclosed Fan Cooled Motor 1-250 HP Rev June 6, 2001 Table of Contents 1.0 Purpose 2.0 Scope Baldor Electric Company Premium Efficiency Motor Specification Totally Enclosed Fan Cooled Motor 1-250 HP Rev June 6, 2001 3.0 Motor Requirements 3.1 Applicable

More information

AC METRIC (IEC) MOTORS THREE PHASE

AC METRIC (IEC) MOTORS THREE PHASE AC METRIC MOTORS These high efficiency motors meet North American performance standards and EPACT energy efficiency mandates, and have.5 service factors. Typically used for replacement on machine tools,

More information

Baldor Electric Company Premium Efficiency Motor Specification Open Drip-Proof Motors 1-500 HP Rev June 6, 2001

Baldor Electric Company Premium Efficiency Motor Specification Open Drip-Proof Motors 1-500 HP Rev June 6, 2001 Table of Contents 1.0 Purpose 2.0 Scope Baldor Electric Company Premium Efficiency Motor Specification Open Drip-Proof Motors 1-500 HP Rev June 6, 2001 3.0 Motor Requirements 3.1 Applicable Codes and Regulations

More information

Solving VFD-sourced Bearing Current Problems in AC Motors.

Solving VFD-sourced Bearing Current Problems in AC Motors. Solving VFD-sourced Bearing Current Problems in AC Motors. The 2 main sources of motor shaft voltage are: 1. Asymmetric Motor construction The stator and rotor magnetic circuits within the motor itself

More information

EBS852 (Contrac) Power Electronic Unit

EBS852 (Contrac) Power Electronic Unit Data Sheet Rev. A EBS852 (Contrac) Power Electronic Unit For continuous control of Contrac actuators RHD(E) and RSD(E) Microprocessor-controlled power electronic unit with integrated frequency converter

More information

Liquid Level Limit Switch liquiphant T FTL 20

Liquid Level Limit Switch liquiphant T FTL 20 Technical Information TI 64F/4/ae Liquid Level Limit Switch liquiphant T FTL 0 Level limit switch for liquids Applications The Liquiphant T FTL 0 is a level limit switch for virtually any kind of fluid

More information

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS D R I V E S Y S T E M S PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS The vision of Iskra Avtoelektrika is to be: One of the world's leading manufacturers of electric motors and controllers for

More information

BMD. Permanent Magnet AC Synchronous Motors

BMD. Permanent Magnet AC Synchronous Motors BMD Permanent Magnet AC Synchronous Motors Power, control and green solutions About us 3 Bonfiglioli, one name for a large international group. It was back in 1956 that Clementino Bonfiglioli established

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Stock and Custom AC and DC

Stock and Custom AC and DC Bulletin 1800 PRECISION SB-FHP MOTORS Stock and Custom AC and DC Precision Sub-FHP Motors Custom or Off-The-Shelf LEESON Electric is one of North America s youngest and fastest-growing motor companies.

More information

GE Power Conversion. Generators. 2,500 to 80,000 kva Up to 22,000 Volts

GE Power Conversion. Generators. 2,500 to 80,000 kva Up to 22,000 Volts GE Power Conversion Generators 2,500 to 80,000 kva Up to 22,000 Volts 2 GE I Power Conversion GE has been setting the standard in generator manufacturing for over 130 years. GE created and implemented

More information

Controlled Start transmission

Controlled Start transmission Controlled Start transmission TM What CSt does The DODGE CST (Controlled Start Transmission) is a 2 in 1 gearbox which combines a planetary gear reducer with an integral wet clutch system. When coupled

More information

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive

More information

HVAC DRIVE H300 HVAC Drive for Building Automation

HVAC DRIVE H300 HVAC Drive for Building Automation HVAC DRIVE H300 HVAC Drive for Building Automation 1.0 hp - 450 hp (0.75 kw - 336 kw) 208 V - 230 V 400 V 575 V EMERSON Leading the world in climate technologies CONSIDER IT SOLVED. Emerson s promise to

More information

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:

More information

AC Servo Motors and Servo Rated Gearheads

AC Servo Motors and Servo Rated Gearheads AC Servo Motors and Servo Rated Gearheads for the automation industry Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8)

More information

2100, 2200, 2300, 4100, 6200, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors

2100, 2200, 2300, 4100, 6200, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors 00, 00, 300, 400, 600, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors Installation, Maintenance & Parts Manual Featuring: Technology DORNER MFG. CORP. INSIDE THE USA OUTSIDE

More information

solutions Baldor Is Redefining the Future of Cooling Tower Performance with Innovative 'Green' Motor and Drive Technology Plus

solutions Baldor Is Redefining the Future of Cooling Tower Performance with Innovative 'Green' Motor and Drive Technology Plus solutions A Publication Featuring Baldor Electric Company Products Number 4 magazine Baldor Is Redefining the Future of Cooling Tower Performance with Innovative 'Green' Motor and Drive Technology Plus

More information

Baldor Electric ProSPEC MASTERFORMAT SPECIFICATION May 3, 2005. A. This specification covers integral horsepower squirrel cage AC induction motors.

Baldor Electric ProSPEC MASTERFORMAT SPECIFICATION May 3, 2005. A. This specification covers integral horsepower squirrel cage AC induction motors. SECTION 16221 - TEFC AC INDUCTION MOTORS PART 1 - GENERAL 1.1 SUMMARY A. This specification covers integral horsepower squirrel cage AC induction motors. B. This specification is intended to specify superior

More information

Your professional Partner also for special Miniseries & special Series.

Your professional Partner also for special Miniseries & special Series. Your professional Partner also for special Miniseries & special Series. Your professional Partner also for special Miniseries and special Series. / Page 1 Company Profile ABM Greiffenberger One of the

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

AC Replacement for DC Mill-Duty Motors

AC Replacement for DC Mill-Duty Motors AC Replacement for DC Mill-Duty Motors This article is available online at www.aist.org for 30 days following publication. For many years, DC mill auxiliary motors for steel mill applications such as screwdowns,

More information

ADJUSTABLE FREQUENCY DRIVES APPLICATION GUIDE

ADJUSTABLE FREQUENCY DRIVES APPLICATION GUIDE ADJUSTABLE FREQUENCY DRIVES APPLICATION GUIDE Adjustable Frequency Drives Application Guide Table of Contents Introduction....................................................................................

More information

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

B a l d o r V S 1 A C M i c r o d r i v e s C o m p a c t. C o s t E f f i c i e n t. R e l i a b l e.

B a l d o r V S 1 A C M i c r o d r i v e s C o m p a c t. C o s t E f f i c i e n t. R e l i a b l e. VS1 AC Microdrives B a l d o r V S 1 A C M i c r o d r i v e s C o m p a c t. C o s t E f f i c i e n t. R e l i a b l e. Quality, reliability, and performance these are characteristics shared by every

More information

SanStar Series SSi and SSO Mixers SANITARY MIXERS

SanStar Series SSi and SSO Mixers SANITARY MIXERS SanStar Series SSi and SSO Mixers SANITARY MIXERS A World Leader In Industrial Mixing Since 1923. Lightnin has 90 years of unrivaled experience in industrial mixing technology, process knowledge, and technological

More information

AC Electric Motors best practice

AC Electric Motors best practice If you want to learn more about best practice machinery maintenance, or world class mechanical equipment maintenance and installation practices, follow the link to our Online Store and see the Training

More information

Flygt 3068, 50Hz. Technical Specification

Flygt 3068, 50Hz. Technical Specification Flygt 3068, 50Hz Technical Specification Table of Contents Table of Contents B-pump...2 Product description...2 Motor rating and performance curves...4 C-pump...6 Product description...6 Motor rating

More information

How To Drive A Compact Serie 1

How To Drive A Compact Serie 1 Electric lifting cylinder Compact Series Table of Contents Glossary... 2 Compact serie SR 1... 4 Dimension SR 1... 5 Compact Serie SR 1SP... 6 Dimension SR 1SP... 7 Compact Serie SR 5... 8 Dimension SR

More information

EVANS ENTErprises, Inc.

EVANS ENTErprises, Inc. EVANS ENTErprises, Inc. Since 1954 THE LEADER IN ELECTRO-MECHANICAL SALES, SERVICE AND INTERGRATION Our Mission Our purpose at Evans Enterprises is to serve customers by providing increased value of product

More information

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. A Regal Brand EVERGREEN SOLUTIONS Powered by ECM Technology Upgrade/Replace PSC motors with Evergreen IM Residential/Light Commercial HVAC Systems Reduce

More information

Introduction. Upon completion of Basics of AC Motors you should be able to:

Introduction. Upon completion of Basics of AC Motors you should be able to: Table of Contents Introduction...2 AC Motors...4 Force and Motion...6 AC Motor Construction... 12 Magnetism... 17 Electromagnetism... 19 Developing a Rotating Magnetic Field...24 Rotor Rotation...29 Motor

More information

North America. Discrete Automation and Motion Delivering customer value together

North America. Discrete Automation and Motion Delivering customer value together North America Discrete Automation and Motion Delivering customer value together About ABB ABB is a global leader in power and automation technologies that enable utility and industry customers to improve

More information

AC motors catalogue. www.parvalux.com

AC motors catalogue. www.parvalux.com 00 AC motors catalogue www.parvalux.com :: geared motors :: legendary reliability :: totally customisable :: Product guide DC brushless (PBL) DC permanent magnet (PM) AC induction (SD) motors only Type

More information

Permanent Magnet DC Motors

Permanent Magnet DC Motors typical applications Robotics and factory automation Pick-and-place robots Positioning tables Welding wire feeders Automatic guided vehicles Barcoding equipment Computer and office equipment Copier and

More information

ENGINEERING BULLETIN No. EB 039 Product: Cooling Towers, Closed Circuit Coolers & Evaporative Condensers Date: June 2003

ENGINEERING BULLETIN No. EB 039 Product: Cooling Towers, Closed Circuit Coolers & Evaporative Condensers Date: June 2003 For Distribution ENGINEERING BULLETIN No. EB 039 Product: Cooling Towers, Closed Circuit Coolers & Evaporative Condensers Date: June 2003 Purpose: Variable Frequency Drives The purpose of this Engineering

More information

COOLING TECHNOLOGY INSTITUTE

COOLING TECHNOLOGY INSTITUTE PAPER NO: CATEGORY: TP09-18 FANS COOLING TECHNOLOGY INSTITUTE RECENT DEVELOPMENTS IN MOTOR TECHNOLOGY ALLOW DIRECT DRIVE OF LOW SPEED COOLING TOWER FANS ROBBIE MCELVEEN BILL MARTIN RYAN SMITH BALDOR ELECTRIC

More information

Unit 33 Three-Phase Motors

Unit 33 Three-Phase Motors Unit 33 Three-Phase Motors Objectives: Discuss the operation of wound rotor motors. Discuss the operation of selsyn motors. Discuss the operation of synchronous motors. Determine the direction of rotation

More information

Brochure. Generators for wind power Proven generators reliable power

Brochure. Generators for wind power Proven generators reliable power Brochure Generators for wind power Proven generators reliable power We provide motors, generators and mechanical power transmission products, services and expertise to save energy and improve customers

More information

INTRODUCTION TO RATIOTROL

INTRODUCTION TO RATIOTROL GEAROLOGY 8-1 8 8-2 GEAROLOGY INTRODUCTION Modern industrial processes require operating speeds that maximize production, profit and quality. Today, these speeds can be achieved through mechanical power,

More information

UM Series UniModule. Pre-assembled, C-face Clutches and Brakes. Original Design Sizes 210 & 215. GEN 2 Design Sizes 50, 100 & 180

UM Series UniModule. Pre-assembled, C-face Clutches and Brakes. Original Design Sizes 210 & 215. GEN 2 Design Sizes 50, 100 & 180 re-assembled, C-face Clutches and Brakes UniModules offer the ultimate in Clutch/ Brake performance and convenience. UniModules offer the same performance as EM s without the assembly required. Completely

More information

Specifying a Variable Frequency Drive s

Specifying a Variable Frequency Drive s Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable

More information

Permanent Magnet Technology within Direct Drive Cooling Tower Motors Creates System Energy Savings

Permanent Magnet Technology within Direct Drive Cooling Tower Motors Creates System Energy Savings Permanent Magnet Technology within Direct Drive Cooling Tower Motors Creates System Energy Savings Roman Wajda, Robbie McElveen, Bill Martin, and Steve Evon, Baldor Electric Company ABSTRACT At a time

More information

DIRECT CURRENT MOTORS & GEARMOTORS

DIRECT CURRENT MOTORS & GEARMOTORS Bulletin 1600IEC PERMANENT MAGNET DIRECT CURRENT MOTORS & GEARMOTORS IEC Frames NEMA Frames Small Frames LEESON Your Complete Source For Quality DC Motors And More Today s LEESON offers one of the industry

More information

Horizontal Jet Pumps 1/3-1-1/2 HP

Horizontal Jet Pumps 1/3-1-1/2 HP Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The

More information

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution

More information

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1HP 350HP 200 480V Single & 3 Phase Input

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1HP 350HP 200 480V Single & 3 Phase Input AC Variable Speed Drive Powerful Performance Advanced motor control 0.75kW 250kW / 1HP 350HP 200 480V Single & 3 Phase Input At a Glance High performance, excellent usability and flexible to meet the needs

More information

Explosion Proof Dynamic Brushless Servo Motors

Explosion Proof Dynamic Brushless Servo Motors Explosion Proof Dynamic Brushless Servo Motors ExD SERIES OFFERING HIGH PERFORMANCE SERVO MOTORS FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES IN ACCORDANCE WITH ATEX AND IECEx Rev. C, October Explosion

More information

TorqPlus TM Electric Valve Actuators and Controls

TorqPlus TM Electric Valve Actuators and Controls TorqPlus TM Electric Valve Actuators and Controls Torque 150 IN/LB 600 IN/LB The Engineered Solution Bettis TorqPlus quality line of electric actuators are designed for quarter turn applications ball,

More information

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7 Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: sales@hydronit.com Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Thermometer in stainless steel with capillary and switch contacts

Thermometer in stainless steel with capillary and switch contacts Design Type Case diameter Thermometer in and switch contacts 7308 = back flange for wall mounting 7312 = front flange for panel mounting 7310 = mounting bracket for wall mounting Dim 100 mm or 160 mm Accuracy

More information

300 Series PA Pump and Cooler Assemblies

300 Series PA Pump and Cooler Assemblies Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate

More information

Reliance Electric GV3000/SE Industrial AC Drive

Reliance Electric GV3000/SE Industrial AC Drive Reliance Electric GV3000/SE Industrial AC Drive Multi-Purpose variable speed control of 1-400 HP three-phase motors, with Volts/Hertz or Vector mode operation as standard FLEXIBLE Control Whether you need

More information

vacon ac drives for mining & minerals

vacon ac drives for mining & minerals vacon ac drives for mining & minerals 1 strong experience in mining & minerals Vacon AC drives are robust to handle your most demanding requirements from simple ventilation to the most complex load sharing

More information

AC ADJUSTABLE SPEED DRIVES MICRO SERIES INVERTERS

AC ADJUSTABLE SPEED DRIVES MICRO SERIES INVERTERS MICRO SERIES INVERTERS MICRO SERIES INVERTER DRIVES Full feature, ultra-friendly operation. Programs and reads-out in plain English. Intelligent Power Module-IGBT s with a 16 bit Intel microprocessor.

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

Induction Motor Theory

Induction Motor Theory PDHonline Course E176 (3 PDH) Induction Motor Theory Instructor: Jerry R. Bednarczyk, P.E. 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088 www.pdhonline.org

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

IP Rating Chart. 910 East Orangefair Lane Anaheim, CA 92801 USA. www.anaheimautomation.com 714-992-6990 714-992-0471, Fax

IP Rating Chart. 910 East Orangefair Lane Anaheim, CA 92801 USA. www.anaheimautomation.com 714-992-6990 714-992-0471, Fax IP, NEMA and UL Rating Codes The International Protection Rating, sometimes referred to as an Ingress Protection rating, is a set of codes used to define specific levels of protection. These codes consist

More information

A1000 Cheat Sheet (Open Loop Vector)

A1000 Cheat Sheet (Open Loop Vector) A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to

More information

Panorama. Softstarters The complete range

Panorama. Softstarters The complete range Panorama Softstarters The complete range Why does soft starting matter? Controlling industrial electricity. The vast majority of the world s industrial applications are driven by motors. It is estimated

More information