General Information. ME-business can be accessed through: www. marathonelectric.com.
|
|
- Lewis Camron Mason
- 7 years ago
- Views:
Transcription
1 MARATHON ELECTRIC Since 1913, Marathon Electric s name has been recognized for engineering excellence, custom-designed products and an extensive product line of industrial quality motors. Available in all popular enclosures from 1/12 HP through 3000 HP and in a variety of mounting configurations, Marathon Electric s unique designs provide more ways in which to add accessories, such as blowers, brakes and encoders, to our motors than anyone else in the motor business. Our state-of-the-art lab facilities are equipped and staffed with the finest resources available to ensure successful utilization of our products. Finally, as the preferred supplier of motors to most of the top drive manufacturers in North America, we have what it takes to be a leader in understanding the interaction of drives as they are applied with AC induction motors. WEBSITE AND E-COMMERCE Information can be accessed instantly, any time of the day on ME-business. Marathon customers can sign-up for ME-business by contacting their sales representative. ME-business can be accessed through: www. marathonelectric.com. Stock Availability Order Status Shipping Information Invoice Information Product features and performance data Marathon Electric Nameplate Information - HOW TO READ A MARATHON ELECTRIC NAMEPLATE The nameplate is the key to selecting the proper replacement motor Motor Specifications (Example) Agency Symbols CSA Verification Mark - Complies with CSA s Energy Efficiency Verification Service and their Standard C390 - C390 is the Canadian efficiency equivalent of EPAct. Underwriters Laboratories, Inc. UL Recognized Component Mark UL file # CE (Conformité Européene) Marking This mark signifies the motor complies with the European Low Voltage Directive. CSA Mark - Certified by the Canadian Standards Association CSA file # CC# - Compliance Certification Number as per assigned by the Department of Energy. Motors meeting EPAct efficiencies or higher will have this number. 1. MODEL - The ID number 2. DATE CODE - The month and year manufactured 3. MTG. - Mounting 4. FRAME - The size & mounting 5. PART NO. - Customer part number 6. SER. - Serial number 7. TYPE - Electrical type 8. DES. - Code by NEMA or IEC 9. PH - Electrical phase usually 1 or INS CL - Insulation Class 11. DUTY - Time rating under load 12. MAX AMB - The allowable surrounding air temperature 13. ENCL - Enclosure (i.e. TEFC) 14. RISE - The temperature rise over ambient expressed in degrees Celsius when the motor operates at nameplated HP or KW 15. IP - Inherent Protection of the enclosure to solids and liquids as defined by IEC IC - Inherent Cooling 17. CODE - NEMA locked-rotor KVA 18. MTH/YR MFG. - Month and year motor was manufactured 19. WT/LBS - Motor weight in pounds 20. WT/KG - Motor weight in kilograms 21. HZ - Input frequency of the power supply, usually 50 or 60 HZ 22. VOLTS - Voltage rating of the motor at the operating frequency 23. HP - Rated horsepower the motor will produce 24. KW - Rated output in watts 25. F.L. AMPS - The rated load current expressed in amps at nameplated horsepower with nameplate voltage and frequency 26. S.F. - Percentage of the rated horsepower the motor can safely operate at: Example: 1.15 SF (115% of rated HP) 27. PF / COS - Power Factor / Cosine is the ratio of actual power to the apparent power 28. RPM - Full load speed at rated frequency 29. NOM EFF - Average Efficiency 30. SHAFT END BEARING - Manufacturer drive end bearing number 31. OPP. END BEARING - Manufacturer opposite drive end bearing number 32. SHAFT END BRG - Drive end bearing size 33. OPP - Opposite drive end bearing size 5
2 HOW TO READ A MODEL NUMBER: Each Marathon Electric motor carries a model number that can be used to define some of the motor s physical and electrical characteristics. Example (For Fractional): 1PC48C17D2000AP This is a breakdown of the model on the nameplate: 1 P C 48 C 17 D 2000 A P This is a breakdown of the model in the catalog: 48 C 17 D Example (For Integral): 2QA215TBDRA7076ALL This is a breakdown of the model on the nameplate: 2 Q A 215T B D R A 7076 AL L This is a breakdown of the model in the catalog: 215T B D R A Date Code - Year of Manufacture (Not shown in catalog listings.) 2. Thermal Protection (Not shown in catalog listings.) UL Recognized Motor Protector Combination UL Recognized Motor Construction Automatic Reset Automatic Reset Automatic Reset Q Yes Yes S No No U No Yes W # Yes Manual Reset Manual Reset Manual Reset P Yes Yes Z No Yes X No No None None None V No Yes # Motor protector combination is U.L. recognized only if motor is used in direct drive fan duty application, and is under locked rotor condition, or is running under no-load condition. 5. Electrical Type Single Phase: A = Permanent split capacitor B = Capacitor start, capacitor run C = Capacitor start, induction run N = Split phase start, capacitor run S = Split phase Three Phase: T = Three phase H = Inverter Duty/IEEE841 Inverter Duty V = Medium Voltage DC Power: E = Permanent Magnet DC 6. RPM or Speed at 60 Hz (Fractional Only) 34 = 2-Pole, 3600 rpm 17 = 4-Pole, 1800 rpm 11 = 6-Pole, 1200 rpm 8 = 8-Pole, 900 rpm 7. Enclosure D = Dripproof E = Explosion proof, non-ventilated F = Totally enclosed, fan cooled G = Explosion proof, fan cooled O = Open P = Partial S = Semi-enclosed T = Totally enclosed, non-ventilated V = Washdown, non-ventilated W = Washdown, fan cooled 8. Frame Construction Integral Fractional (where applicable) L = Aluminum (Full Frame) B = Rolled Steel - Sourced Y = Aluminum (Full Frame) D = Stainless Steel - Sourced Z = Aluminum (High Mount Down Frame) U = Frameless - Sourced H = Aluminum - Sourced R = Rolled Steel (Full Frame) W = Rolled Steel (Full Frame) X = Rolled Steel (High Mount Down Frame) B = Rolled Steel - Sourced S = Cast Iron (Full Frame) N = Cast Iron (Full Frame) P = Cast Iron (High Mount Down Frame) C = Cast Iron - Sourced D = Stainless Steel 3. Date Code - Month of Manufacturer (Not shown in catalog listings.) 4. NEMA Frame Size - (Integral motors - T and U designate standard shaft, TS and US designate short shaft) 9. Style Letter (A, B, C, etc. indicate redesign) 10. Sequence Number 11. Minor Modification Letter(s) Fractional - 1 letter; Integral - 2 letters 12. Manufacturing Code - A code for the factory where the motor was manufactured. 6
3 HOW TO READ A MODEL NUMBER: Continued Example ( harmonized motor design): A B C D E F G H 5 KH 3 6 K G 142 X A. Rotating Device B. Type of Winding KH - Split Phase KC - Capacitor Start, Induction Run K - Polyphase KCP - Permanent Split Capacitor KCR - Capacitor Start, Capacitor Run C. Lamination Size 3-48 frame, 4-56 frame D. Length of Frame 48 frame 56 frame None None None Spec. Spec. E. Stack Length A - 5/8 F - 1-1/4 L - 1-7/8 S B - 3/4 G - 1-3/8 M T - 3-1/4 C - 7/8 H - 1-1/2 N - 2-1/4 U - 3-1/2 D J - 1-5/8 P - 2-1/2 W E - 1-1/8 K - 1-3/4 R - 2-3/4 Q - Spec. F. Sequence Number G. Current Revision (blank if original) H. Type of Overload X - UL Auto running & locked rotor Y - UL Manual running & locked rotor S - UL Auto locked rotor T - Non-UL Auto running & locked rotor U - Non-UL Manual running & locked rotor V - Thermostat W - UL Motor Parts ORDERING INFORMATION When ordering, please include the model number, catalog number, description of the motor, quantity, shipping and billing instructions. For pricing of non-stock motors, or if you need assistance in selecting the proper motor, please contact your nearest Marathon Electric sales representative or local Marathon Electric Distributor. All prices and data are subject to change without notice. CANCELLATIONS AND RETURNS Stock Product Stock product can be returned for credit as defined herein. Equipment must be in original packaging, unused in as shipped condition and is limited to products currently maintained in stock inventory. The quantity returned cannot exceed Marathon Electric s normal stock quantity level. All motors returned must have date codes no older than 18 months from date of manufacture. The minimum restocking charge is 15% of the original net purchase price. Modified and build to order motors cannot be returned for credit. Return freight charges are the responsibility of the customer returning the motor for credit. No returns will be accepted without prior authorization. Non-stock Product Cancellation policy: Cancellation charges for non-stock orders received and entered will be determined based on the percentage of completion in the engineering and manufacturing process, accounting for all costs plus a reasonable profit. Marathon Electric s determination of the cancellation charges shall be conclusive. DISCOUNTS AND MULTIPLIERS Except as noted, all prices in this catalog are list prices. 200 and 575 volt 3 phase ratings utilize the same list price as 230/460 volt. NEMA short shaft (TS) utilize the same list price as standard shaft (T). Contact Marathon Electric for special bearing systems, including all requirements for sleeve or roller bearing. For your discount and multiplier, contact your local Marathon Electric sales representative or local Marathon Electric Distributor. MODIFICATION/ACCESSORIES See the Modification/Accessories Sections for more information on modifications to create special motor variations. 7
4 STOCK, NON-STOCK AND BUILD UP MODELS Standard motors listed in this catalog, as indicated with a star (*) next to the catalog number, are normally in stock. There is no minimum order quantity or minimum billing charge associated with stock motors, unless stated otherwise in your quotation or agreement with Marathon Electric. Production of non-stock catalog models and all build-up models is subject to minimum order quantities or setup charges listed below Frame = 25 piece minimum Frames = 5 piece minimum or $200 set-up/model Frames = 5 piece minimum or $300 set-up/model Build-up motors must be thoroughly described at time of order, and/or associated with a formal quotation issued by Marathon Electric. Inclusion of product features for similar motors documented in this catalog should not be assumed. SERVICE For service on any Marathon Electric motor, contact your nearest Marathon Electric Authorized Service Station. For a complete listing of all domestic and foreign service stations, refer to Marathon Electric s brochure, SB112, or OPERATION AND MAINTENANCE For information on operation and maintenance, please consult the manual or card shipped with your new motor. Additional copies of Installation, Operation & Maintenance Instructions (brochure SB181) are available upon request or through our web site, STORAGE PROCEDURES In the event that long-term storage of motors is required, Marathon Electric recommends the following precautions and procedures. This information is also contained in Installation, Operation and Maintenance Instructions (SB181). A. Keep motors clean 1. Store indoors 2. Keep covered to eliminate airborne dust and dirt. 3. Cover openings for ventilation, conduit connections, etc., to prevent entry of rodents, snakes, birds and insects. B. Keep motors dry 1. Store in a dry area indoors 2. Temperature swings should be minimal to prevent condensation. 3. Space heaters are recommended to prevent condensation. 4. Treat unpainted flanges, shafts and fittings with a rust inhibitor. 5. Check insulation resistance before putting motor into service. C. Keep bearings lubricated 1. Once per month, rotate shaft several turns to distribute grease in bearings. 2. If unit has been stored more than one year, add grease before start-up (refer to lubrication procedure). DIMENSION DRAWINGS See Table of Contents for the dimension section in this catalog, or request certified drawings through your Marathon Electric Sales Engineer, Representative or local Marathon Electric Distributor. 8
5 WARRANTY Marathon Electric warrants Fractional and Integral motors to be free from defects in materials and workmanship and to conform to Marathon s written specifications. Motor Type Warranty Warranty Period from Period from Date of Date of Installation* Manufacture* Standard Warranty for any product not shown below Medium Voltage EPAct compliant (aluminum, steel & cast iron frame) Blue Chip Severe Duty Explosion Proof Blue Max, Black Max, & micromax Inverter Duty All XRI (NEMA Premium ) incl. ODP, Blue Chip, Severe Duty, Explosion Proof, etc U-Frame Automotive Duty Blue Chip IEEE * Warranty period shown is in months, and is valid for whichever period expires first. Note: Brake discs are considered a normal maintenance item and are not covered under warranty. For more information, on Marathon Electric s warranty policy, refer to the Terms and Conditions of Sale (MPN411) in the back of this catalog. SUBMITTAL DATA Mechanical and electrical submittal data is available on many stock catalog motors through our website by following the three steps listed on the next page. All other submittal data is available upon request when accompanied by a purchase order for the specified motor, subject to the following additional charges SUBMITTAL CHARGE SCHEDULE TYPE ELEMENTS NET/EA Nameplate data Motor characteristics BASIC (.PDF Performance data No-Charge format) Outline drawing External connection diagram Add for.dxf or.dwg format $25 All BASIC elements, tailored to BASIC-PLUS specific order. (.pdf format) Cut sheets of installed accessories $75 Add for.dxf or.dwg format $25 Speed/Torque curve $50 Torque capability curve $50 ADDITIONAL Commercial (end of line) test results (not ITEMS available for West Plains motors)* $50 (.pdf formats) Certificate of conformance $100 Thermal damage curve (48-326T frame) $500 + cost of additional motor Thermal damage curve (364T-6805 frame) $1500 +cost of additional motor * Does not imply retesting 9
6 1. From our homepage, click on the Motors link. From the Motors page, enter in the Marathon Catalog number or Model number. Then click on Model number in results window. (Note: If you already have a Marathon Electric motor and are looking for the performance data, make sure the model number off the nameplate is what you use for your search. Ex. 056H17T5301). 2. The Motor Model Details page will appear. You will be able to print dimensional drawings and connection diagrams in PDF format for the motors. Under the Technical Data section, click on the link, Certification Data Sheet. 3. Your results will look similar to the example shown to the right for Marathon s 1/2 HP, Black Max motor, model # 056H17T5301. It s that easy! 10
We will discuss common industrial applications with guides for the proper use of electric motors on these.
INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which
More informationXRI Severe Duty 143-449T Frame. IEC Globetrotter 63-225M Frame
XRI Severe Duty 143-449T Frame NEMA Premium /XRI - As a leading supplier of premium efficiency motors, we help conserve money and our environment. Marathon s designs are 100% compliant with CEE efficiency
More informationWhat Do All Those Things on an AC Motor Nameplate Mean?
What Do All Those Things on an AC Motor Nameplate Mean? Introduction: Ever order a motor on power, speed, and enclosure? PO says maybe "5 hp, 1,800 rpm, TEFC." New-motor nameplate says "HP 5, RPM 1748,
More informationBasic Nameplate Information
Basic Nameplate Information General Information: Most equipment nameplates will have some common items of information. Many of these are self explanatory, and include: Manufacturer Manufacturerʼs address
More informationINSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check
More informationThe Energy Independence and Security Act of 2007. The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010
The Energy Independence and Security Act of 2007 The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010 January 23, 2009 To Our Customers, Baldor Electric Company 5711 R.S.
More informationBaldor Electric Position on DOE Small Motor Rule
Baldor Electric Position on DOE Small Motor Rule WP0035 WP0034 Page 1 of 6 US Integral DOE Small HP Motor Rule Rule Baldor Electric Position on DOE Small Motor Rule 10/28/14 On March 9, 2010 the US Department
More informationApplication Information
AGENCY LISTINGS UL and CSA Marathon Electric s Fire Pump and Explosion Proof motors are UL Listed. Other motor types are UL Recognized, including models with inherent overheating protection as noted (i.e.
More informationSEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor
INSTALLATION, OPERATION AND MAINTENANCE MANUAL For SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor Yeomans Chicago Corporation 3905 Enterprise Court P.O. Box 6620 Aurora, IL 60598-0620 Phone:
More informationAC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles
AC Induction Motors Simplest and most rugged electric motor Consists of wound stator and rotor assembly AC in the primary member (stator) induces current in the secondary member (rotor) Combined electromagnetic
More informationMotor Specifications. Nameplate
Motor Specifications Nameplate The nameplate of a motor provides important information necessary for selection and application. The following drawing illustrates the nameplate of a sample 30 horsepower
More informationBaldor Electric ProSPEC MASTERFORMAT SPECIFICATION May 3, 2005. A. This specification covers integral horsepower squirrel cage AC induction motors.
SECTION 16221 - TEFC AC INDUCTION MOTORS PART 1 - GENERAL 1.1 SUMMARY A. This specification covers integral horsepower squirrel cage AC induction motors. B. This specification is intended to specify superior
More informationRotary Phase Converters
FACTS from Ronk Electrical Industries, Inc. Bulletin 11981 Rotary Phase Converters ROTOVERTER Pat. No. 3,670,238 ROTO-CON Pat. No. 4,158,225 What are the ROTO-CON and ROTOVERTER power converters? The ROTO-CON
More informationSECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
More informationIntroduction. Upon completion of Basics of AC Motors you should be able to:
Table of Contents Introduction...2 AC Motors...4 Force and Motion...6 AC Motor Construction... 12 Magnetism... 17 Electromagnetism... 19 Developing a Rotating Magnetic Field...24 Rotor Rotation...29 Motor
More informationLow Voltage Transformers Sealed, General Purpose, Dry Type
Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................
More informationAC Replacement for DC Mill-Duty Motors
AC Replacement for DC Mill-Duty Motors This article is available online at www.aist.org for 30 days following publication. For many years, DC mill auxiliary motors for steel mill applications such as screwdowns,
More informationSpecifying a Variable Frequency Drive s
Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable
More informationInstallation, Operation and Maintenance Instructions
Installation, Operation and Maintenance Instructions for AC Induction Motors 56-6800 Frames (NEMA) 63 280 Frames (IEC) MARATHON ELECTRIC Contact Motor Customer Service at: Phone: (75) 675-33 www.marathonelectric.com
More informationThe Ultimate Truck Stock Motor
The Ultimate Truck Stock Motor What is a Rescue Motor? Universal Replacement Motor for Condenser Fan and Direct Drive Blower Applications Multi-Horsepower PSC Motors Flexible Mounting Options Permanent
More informationBaldor Electric Company Premium Efficiency Motor Specification Open Drip-Proof Motors 1-500 HP Rev June 6, 2001
Table of Contents 1.0 Purpose 2.0 Scope Baldor Electric Company Premium Efficiency Motor Specification Open Drip-Proof Motors 1-500 HP Rev June 6, 2001 3.0 Motor Requirements 3.1 Applicable Codes and Regulations
More informationPump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More information26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
More informationPermanent Magnet DC Motors
typical applications Robotics and factory automation Pick-and-place robots Positioning tables Welding wire feeders Automatic guided vehicles Barcoding equipment Computer and office equipment Copier and
More informationBaldor Electric Company Premium Efficiency Motor Specification Totally Enclosed Fan Cooled Motor 1-250 HP Rev June 6, 2001
Table of Contents 1.0 Purpose 2.0 Scope Baldor Electric Company Premium Efficiency Motor Specification Totally Enclosed Fan Cooled Motor 1-250 HP Rev June 6, 2001 3.0 Motor Requirements 3.1 Applicable
More informationAC METRIC (IEC) MOTORS THREE PHASE
AC METRIC MOTORS These high efficiency motors meet North American performance standards and EPACT energy efficiency mandates, and have.5 service factors. Typically used for replacement on machine tools,
More informationMasterFit. The Serviceman s Best Friend!
MasterFit The Serviceman s Best Friend! MasterFit : One Motor Replaces Many Features: Energy Efficient Different Capacitor/ Speed Combinations Designed for 370V Capacitor (not furnished) Permanent Split
More informationMTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
More informationWhy Baldor? Table of Contents. www.baldor.com
Pump Motors Why Baldor? Industry s shortest lead times/flexible manufacturing. Baldor has the industry s shortest lead times on custom motors just ten working days. Our unique LEAN FLEX FLOW manufacturing
More informationTERMINAL MARKINGS AND CONNECTIONS PART WINDING START
TERMINAL MARKINGS AND CONNECTIONS PART WINDING START NEMA NOMENCLATURE 6 LEADS 7 7 3 9 8 Delta 3 9 8 Wye OPER. 9 MODE L L L3 OPEN 7 START 3 7,8,9 T T T3 T7 T8 T9 RUN,7,8 3,9 3 8 MOTOR LEADS 3 7 Double
More informationData Sheet. AC Industrial Electric Motors
Data Pack B Issued ovember 2005 1502325812 Data Sheet AC Industrial Electric Motors Standards organisations The RS-ABB range of ac induction motors is produced to common European standards, these being
More informationREB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The
More informationGE Industrial Systems. AC Motor Selection and Application Guide
apple GE Industrial Systems AC Motor Selection and Application Guide TABLE OF CONTENTS Voltage... 2 Frequency... 3 Phase... 4 Motor Output Rating... 4 Polyphase Motors... 4 Single-phase Motors... 4 Service
More informationElectric Motor Brake Horsepower Calculations
Electric Motor Brake Horsepower Calculations By Norm Christopherson These motor calculations are contained here as they apply to the changing conditions of the blower motor when pulley adjustments are
More informationProduct Brochure. Certified Mining Motors
Product Brochure Certified Mining Motors Profile Baldor Electric Company (a member of the ABB group) is a world leader in motors for the mining industry. In the continuous (24/7) operation of underground
More informationDirect drive vane axial fans. These totally enclosed/air over motors must be mounted within the airstream for proper cooling.
Heating, Ventilating, Air Conditioning Aeration Fan, Single Phase Totally, Air Over, Rigid Base Direct drive vane axial fans. These totally enclosed/air over motors must be mounted within the airstream
More informationAC Electric Motors best practice
If you want to learn more about best practice machinery maintenance, or world class mechanical equipment maintenance and installation practices, follow the link to our Online Store and see the Training
More informationSolving VFD-sourced Bearing Current Problems in AC Motors.
Solving VFD-sourced Bearing Current Problems in AC Motors. The 2 main sources of motor shaft voltage are: 1. Asymmetric Motor construction The stator and rotor magnetic circuits within the motor itself
More informationTECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
More informationGE Industrial Systems. AC Motor Selection and Application Guide
apple GE Industrial Systems AC Motor Selection and Application Guide TABLE OF CONTENTS Voltage... 2 Frequency... 3 Phase... 4 Motor Output Rating... 4 Polyphase Motors... 6 Single-phase Motors... 9 Service
More informationPrinciples of Adjustable Frequency Drives
What is an Adjustable Frequency Drive? An adjustable frequency drive is a system for controlling the speed of an AC motor by controlling the frequency of the power supplied to the motor. A basic adjustable
More informationSECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
More informationIndustrial Control Power Transformers
Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments
More informationMiniature High-Torque, DC Servomotors and DC Gearmotors
typical applications Robotics Factory automation Medical equipment Computer peripherals and office equipment Portable, battery-operated equipment Textile machinery Packaging machinery Actuators Miniature
More information3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?
Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 1) What is a transformer and how does it work? A transformer
More informationInstallation Manual Version 7.3 IMPORTANT:
Installation Manual Version 7.3 IMPORTANT: READ ENTIRE MANUAL CAREFULLY, THIS PHASE CONVERTER MUST BE INSTALLED BY A INDUSTRIAL LICENSED ELECTRICIAN 230 VOLTS MODEL ONLY READ FIRST!!!!!! DANGER: HIGH VOLTAGE
More informationMotor Accessories. C-Face Kits for Field Conversion NEMA AC Motors
C-Face Kits for Field Conversion NEMA AC s Features: Complete kits with all hardware necessary for converting Baldor 56 though 449T frame ridgid base motors to C-Face mounting with base. For Baldor conversion,
More informationAC Kinetics Variable Frequency Drive Comparative Transient Inertial Testing. This document was prepared by Advanced Energy.
AC Kinetics Variable Frequency Drive Comparative Transient Inertial Testing This document was prepared by Advanced Energy. December 12 th, 2014 Introduction In June of this year, AC Kinetics contacted
More informationFundamentals of Inverter Fed Motors
Fundamentals of Inverter Fed Motors Technical Manual 10/02 MN780 Contents Page The Growing Use Of Inverters.................................................................. 1 How Inverters Affect Motors....................................................................
More informationADDENDUM #1(BID PACKAGE # 3)
H2Engineering, Inc. 114 East Fifth Avenue Tallahassee, FL 32303 Phone 850.224.7922 Fax 850.224.5876 ADDENDUM #1(BID PACKAGE # 3) To: Jeff Williams From: Peter Lindstrom Co: Leon County Date: October 04,
More informationPump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationSingle Phase Soft Starter
Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................
More informationREVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)
SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY
More informationSingle-Phase AC Synchronous Generator
ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description
More information300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
More informationOJ L 191, 23.7.2009, p. 26. OJ L 2, 7.1.2014, p. 1.
Table of Contents 1. Purpose of the guidelines and disclaimer... 2 1.1. The Regulations... 2 2. Scope... 2 3. Historic developments... 4 4. Scope and Requirements... 5 4.1. Scope... 5 4.2. Requirements...
More informationWE-350 Series ¼ Turn Electric Actuator
WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information
More informationI hope you find them useful and I would appreciate any comments or thoughts you might have for future improvements, corrections or topics.
COWERN PAPERS Baldor Electric Company 5711 R.S. Boreham Jr. Street Fort Smith, AR 72901 Phone (479) 646-4711 Fax (479) 648-5792 www.baldor.com Enclosed you will find a set of papers that I have written
More informationPRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS
D R I V E S Y S T E M S PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS The vision of Iskra Avtoelektrika is to be: One of the world's leading manufacturers of electric motors and controllers for
More informationUnderstanding Energy Efficient Motors
Understanding Energy Efficient Motors Reliable Solutions Today Introduction For anyone who specifies, buys, operates, or repairs electric motors today, the issue of motor efficiency is of growing concern
More informationRegal Beloit AC Motors
Installation, Operation and Maintenance Instructions for Industrial AC Induction Motors 140-6800 Frames (NEMA) 90 280 Frames (IEC) Regal Beloit AC Motors LEESON ELECTRIC Contact Motor Customer Service
More informationTorqPlus TM Electric Valve Actuators and Controls
TorqPlus TM Electric Valve Actuators and Controls Torque 150 IN/LB 600 IN/LB The Engineered Solution Bettis TorqPlus quality line of electric actuators are designed for quarter turn applications ball,
More informationDC MOTORS NEMA FRAME SCR RATED
NEMA FRAME SCR RATED NEMA FRAME MOTORS SCR RATED High voltage permanent magnet DC motors are typically used with an SCR (thyristor) controller in applications requiring adjustable speed and constant torque
More informationPM734F - Technical Data Sheet Winding 28
- Technical Data Sheet Winding 28 SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international standards, including
More informationA1000 Cheat Sheet (Open Loop Vector)
A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to
More information(3) Explosion proof. Designed to prevent ignition of any explosive gases or dust and dirt which may surround the motor.
ELECTRIC MOTORS Enclosures for Motors Types of motor enclosures generally used in farm applications: (1) Open type; drip proof or splash-proof. A general purpose motor for use in dry locations which are
More informationEVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.
EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. A Regal Brand EVERGREEN SOLUTIONS Powered by ECM Technology Upgrade/Replace PSC motors with Evergreen IM Residential/Light Commercial HVAC Systems Reduce
More informationMC1000 Series Installation and Operation Manual
MC1000 Series Installation and Operation Manual NOTE! The manual covers software version M108314 and above. Refer to parameter 63 for the software version of the drive you are working with. If you are
More informationSPEED CONTROL SYSTEM
SPEED CONTROL SYSTEM INDEX SPEED CONTROL MOTOR FEATURES 144 6W ( 70mm) 153 10W ( 70mm) 155 15W ( 80mm) 157 25W ( 80mm) 159 40W ( 90mm) 161 SPEED CONTROL W ( 90mm) 163 90W ( 90mm) 165 120W ( 90mm) 168 180W
More informationPANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual
PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual A Regal Brand TABLE OF CONTENTS INTRODUCTION 2 General Data 2 Initial Inspection 2 SAFETY 2 INSTALLATION 3 Location / Environment
More informationPlug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
More informationWound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP
Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP ABB The Preferred Partner Egypt Cement Corporation, a major cement manufacturer, has chosen ABB wound rotor motors for all key applications
More informationIntroduction. Three-phase induction motors are the most common and frequently encountered machines in industry
Induction Motors Introduction Three-phase induction motors are the most common and frequently encountered machines in industry - simple design, rugged, low-price, easy maintenance - wide range of power
More informationETZGAR CONVEYOR COMPANY Controls Section v12.05
Section 7 Controls Page Description 7-1 Controls Index 7-2 Motor Data, Enclosure Rating and Abbreviations 7-3 Controls Safety Guidelines 7-4 Fixed Speed Controls Packages 7-5 Three Phase AC Variable Speed
More informationSINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006
SINGLE PHASE MOTORS INSTALLATION AND MAINTENANCE MANUAL March 21, 2006 Irvine, California (800) 474-0520 Indianapolis, Indiana (800) 866-7973 Hamilton, Ontario (800) 809-0330 e-mail: sales@sterlingelectric.com
More informationIEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual
IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual 7/09 MN301 Table of Contents Section 1 General Information.................................................. 1-1 Overview........................................................
More informationHPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80
Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...
More informationModel 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com
Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022
More informationMotor Protection Voltage Unbalance and Single-Phasing
Motor Protection Voltage Unbalance and Single-Phasing Cooper Bussmann contributes the following information, which is an excerpt from their 190-page handbook SPD Selecting Protective Devices Based on the
More information543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
More informationOPERATING MANUAL CONTRACTOR STYLE AXIAL FANS
Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN
More informationCURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X
CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD
More informationPRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
More informationREGAL-BELOIT. Installation and Operation Manual. Variable Speed AC Motor Drives. Micro and PowerWash Series
REGAL-BELOIT Variable Speed AC Motor Drives Micro and PowerWash Series Installation and Operation Manual Manual Number: SB184 TABLE OF CONTENTS 1.0 GENERAL................................................1
More informationEffective: September 10, 2006 Vermont Attachment 1 to Rule 5.500 Public Service Board Page 1 of 6
Public Service Board Page 1 of 6 STANDARD APPLICATION FOR INTERCONNECTION OF GENERATION RESOURCES IN PARALLEL TO THE ELECTRIC SYSTEM OF: (Interconnecting Utility) Preamble and Instructions: An owner of
More informationELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION
ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION SC ELECTROPUTERE SA SC ELECTROPUTERE SA 1. Vision, Mission, Values SC ELECTROPUTERE SA 2. LOCATION Craiova: Located in the South West of the country,
More informationAll work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
More informationThree-phase AC circuits
Three-phase AC circuits This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit http://creativecommons.org/licenses/by/1.0/,
More informationAC Servo Motors and Servo Rated Gearheads
AC Servo Motors and Servo Rated Gearheads for the automation industry Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8)
More informationCOOLING TECHNOLOGY INSTITUTE
PAPER NO: CATEGORY: TP09-18 FANS COOLING TECHNOLOGY INSTITUTE RECENT DEVELOPMENTS IN MOTOR TECHNOLOGY ALLOW DIRECT DRIVE OF LOW SPEED COOLING TOWER FANS ROBBIE MCELVEEN BILL MARTIN RYAN SMITH BALDOR ELECTRIC
More informationICQ Series - square centrifugal
product ICQ Square Centrifugal (TEFC) dimensions mm 280-710 poles & duty 4-8 / up to 4,500 L/s application High performance centrifugal fans for medium to high pressure ducted systems. ICQ Series The ICQ
More information3790 en - 06.2007 / d. Alternators LSA 46.2-4 Pole. Electrical and mechanical data
379 en - 6.7 / d Alternators LSA 46.2-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 46.2 alternator is designed to be suitable for typical generator applications, such
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationMotor and Drives Price Book
Motor and Drives Price Book Effective: 06-14-15 QUALITY STATEMENT TECO-Westinghouse Motor Company is committed to serving the needs of our customers BETTER THAN ANYONE ELSE by providing products and services
More informationSUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2
SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 APPROVED NO : APPROVED BY : (AUTHORIZED) SPEC.NO D600023 ISSUE DATE 08.06.1998 DAWN.
More informationO-I DUBI PLANT FANS Quotation Spec Data & Specifications
TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement
More informationHQ Series ¼ Turn Actuator
HQ Series ¼ Turn Actuator HQ-015 thru HQ-300 Installation & Maintenance Manual HQ Series I&M Manual HQ-400-1005 1 Table of Contents: General 1.0 Actuator Mounting 2.0 External Construction 3.0 Wiring Diagrams
More informationDistribution Dry Type Transformers
8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg
More information2100, 2200, 2300, 4100, 6200, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors
00, 00, 300, 400, 600, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors Installation, Maintenance & Parts Manual Featuring: Technology DORNER MFG. CORP. INSIDE THE USA OUTSIDE
More informationSECTION 26 29 23 VARIABLE FREQUENCY DRIVES
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02
More information