General Information. ME-business can be accessed through: www. marathonelectric.com.

Size: px
Start display at page:

Download "General Information. ME-business can be accessed through: www. marathonelectric.com."

Transcription

1 MARATHON ELECTRIC Since 1913, Marathon Electric s name has been recognized for engineering excellence, custom-designed products and an extensive product line of industrial quality motors. Available in all popular enclosures from 1/12 HP through 3000 HP and in a variety of mounting configurations, Marathon Electric s unique designs provide more ways in which to add accessories, such as blowers, brakes and encoders, to our motors than anyone else in the motor business. Our state-of-the-art lab facilities are equipped and staffed with the finest resources available to ensure successful utilization of our products. Finally, as the preferred supplier of motors to most of the top drive manufacturers in North America, we have what it takes to be a leader in understanding the interaction of drives as they are applied with AC induction motors. WEBSITE AND E-COMMERCE Information can be accessed instantly, any time of the day on ME-business. Marathon customers can sign-up for ME-business by contacting their sales representative. ME-business can be accessed through: www. marathonelectric.com. Stock Availability Order Status Shipping Information Invoice Information Product features and performance data Marathon Electric Nameplate Information - HOW TO READ A MARATHON ELECTRIC NAMEPLATE The nameplate is the key to selecting the proper replacement motor Motor Specifications (Example) Agency Symbols CSA Verification Mark - Complies with CSA s Energy Efficiency Verification Service and their Standard C390 - C390 is the Canadian efficiency equivalent of EPAct. Underwriters Laboratories, Inc. UL Recognized Component Mark UL file # CE (Conformité Européene) Marking This mark signifies the motor complies with the European Low Voltage Directive. CSA Mark - Certified by the Canadian Standards Association CSA file # CC# - Compliance Certification Number as per assigned by the Department of Energy. Motors meeting EPAct efficiencies or higher will have this number. 1. MODEL - The ID number 2. DATE CODE - The month and year manufactured 3. MTG. - Mounting 4. FRAME - The size & mounting 5. PART NO. - Customer part number 6. SER. - Serial number 7. TYPE - Electrical type 8. DES. - Code by NEMA or IEC 9. PH - Electrical phase usually 1 or INS CL - Insulation Class 11. DUTY - Time rating under load 12. MAX AMB - The allowable surrounding air temperature 13. ENCL - Enclosure (i.e. TEFC) 14. RISE - The temperature rise over ambient expressed in degrees Celsius when the motor operates at nameplated HP or KW 15. IP - Inherent Protection of the enclosure to solids and liquids as defined by IEC IC - Inherent Cooling 17. CODE - NEMA locked-rotor KVA 18. MTH/YR MFG. - Month and year motor was manufactured 19. WT/LBS - Motor weight in pounds 20. WT/KG - Motor weight in kilograms 21. HZ - Input frequency of the power supply, usually 50 or 60 HZ 22. VOLTS - Voltage rating of the motor at the operating frequency 23. HP - Rated horsepower the motor will produce 24. KW - Rated output in watts 25. F.L. AMPS - The rated load current expressed in amps at nameplated horsepower with nameplate voltage and frequency 26. S.F. - Percentage of the rated horsepower the motor can safely operate at: Example: 1.15 SF (115% of rated HP) 27. PF / COS - Power Factor / Cosine is the ratio of actual power to the apparent power 28. RPM - Full load speed at rated frequency 29. NOM EFF - Average Efficiency 30. SHAFT END BEARING - Manufacturer drive end bearing number 31. OPP. END BEARING - Manufacturer opposite drive end bearing number 32. SHAFT END BRG - Drive end bearing size 33. OPP - Opposite drive end bearing size 5

2 HOW TO READ A MODEL NUMBER: Each Marathon Electric motor carries a model number that can be used to define some of the motor s physical and electrical characteristics. Example (For Fractional): 1PC48C17D2000AP This is a breakdown of the model on the nameplate: 1 P C 48 C 17 D 2000 A P This is a breakdown of the model in the catalog: 48 C 17 D Example (For Integral): 2QA215TBDRA7076ALL This is a breakdown of the model on the nameplate: 2 Q A 215T B D R A 7076 AL L This is a breakdown of the model in the catalog: 215T B D R A Date Code - Year of Manufacture (Not shown in catalog listings.) 2. Thermal Protection (Not shown in catalog listings.) UL Recognized Motor Protector Combination UL Recognized Motor Construction Automatic Reset Automatic Reset Automatic Reset Q Yes Yes S No No U No Yes W # Yes Manual Reset Manual Reset Manual Reset P Yes Yes Z No Yes X No No None None None V No Yes # Motor protector combination is U.L. recognized only if motor is used in direct drive fan duty application, and is under locked rotor condition, or is running under no-load condition. 5. Electrical Type Single Phase: A = Permanent split capacitor B = Capacitor start, capacitor run C = Capacitor start, induction run N = Split phase start, capacitor run S = Split phase Three Phase: T = Three phase H = Inverter Duty/IEEE841 Inverter Duty V = Medium Voltage DC Power: E = Permanent Magnet DC 6. RPM or Speed at 60 Hz (Fractional Only) 34 = 2-Pole, 3600 rpm 17 = 4-Pole, 1800 rpm 11 = 6-Pole, 1200 rpm 8 = 8-Pole, 900 rpm 7. Enclosure D = Dripproof E = Explosion proof, non-ventilated F = Totally enclosed, fan cooled G = Explosion proof, fan cooled O = Open P = Partial S = Semi-enclosed T = Totally enclosed, non-ventilated V = Washdown, non-ventilated W = Washdown, fan cooled 8. Frame Construction Integral Fractional (where applicable) L = Aluminum (Full Frame) B = Rolled Steel - Sourced Y = Aluminum (Full Frame) D = Stainless Steel - Sourced Z = Aluminum (High Mount Down Frame) U = Frameless - Sourced H = Aluminum - Sourced R = Rolled Steel (Full Frame) W = Rolled Steel (Full Frame) X = Rolled Steel (High Mount Down Frame) B = Rolled Steel - Sourced S = Cast Iron (Full Frame) N = Cast Iron (Full Frame) P = Cast Iron (High Mount Down Frame) C = Cast Iron - Sourced D = Stainless Steel 3. Date Code - Month of Manufacturer (Not shown in catalog listings.) 4. NEMA Frame Size - (Integral motors - T and U designate standard shaft, TS and US designate short shaft) 9. Style Letter (A, B, C, etc. indicate redesign) 10. Sequence Number 11. Minor Modification Letter(s) Fractional - 1 letter; Integral - 2 letters 12. Manufacturing Code - A code for the factory where the motor was manufactured. 6

3 HOW TO READ A MODEL NUMBER: Continued Example ( harmonized motor design): A B C D E F G H 5 KH 3 6 K G 142 X A. Rotating Device B. Type of Winding KH - Split Phase KC - Capacitor Start, Induction Run K - Polyphase KCP - Permanent Split Capacitor KCR - Capacitor Start, Capacitor Run C. Lamination Size 3-48 frame, 4-56 frame D. Length of Frame 48 frame 56 frame None None None Spec. Spec. E. Stack Length A - 5/8 F - 1-1/4 L - 1-7/8 S B - 3/4 G - 1-3/8 M T - 3-1/4 C - 7/8 H - 1-1/2 N - 2-1/4 U - 3-1/2 D J - 1-5/8 P - 2-1/2 W E - 1-1/8 K - 1-3/4 R - 2-3/4 Q - Spec. F. Sequence Number G. Current Revision (blank if original) H. Type of Overload X - UL Auto running & locked rotor Y - UL Manual running & locked rotor S - UL Auto locked rotor T - Non-UL Auto running & locked rotor U - Non-UL Manual running & locked rotor V - Thermostat W - UL Motor Parts ORDERING INFORMATION When ordering, please include the model number, catalog number, description of the motor, quantity, shipping and billing instructions. For pricing of non-stock motors, or if you need assistance in selecting the proper motor, please contact your nearest Marathon Electric sales representative or local Marathon Electric Distributor. All prices and data are subject to change without notice. CANCELLATIONS AND RETURNS Stock Product Stock product can be returned for credit as defined herein. Equipment must be in original packaging, unused in as shipped condition and is limited to products currently maintained in stock inventory. The quantity returned cannot exceed Marathon Electric s normal stock quantity level. All motors returned must have date codes no older than 18 months from date of manufacture. The minimum restocking charge is 15% of the original net purchase price. Modified and build to order motors cannot be returned for credit. Return freight charges are the responsibility of the customer returning the motor for credit. No returns will be accepted without prior authorization. Non-stock Product Cancellation policy: Cancellation charges for non-stock orders received and entered will be determined based on the percentage of completion in the engineering and manufacturing process, accounting for all costs plus a reasonable profit. Marathon Electric s determination of the cancellation charges shall be conclusive. DISCOUNTS AND MULTIPLIERS Except as noted, all prices in this catalog are list prices. 200 and 575 volt 3 phase ratings utilize the same list price as 230/460 volt. NEMA short shaft (TS) utilize the same list price as standard shaft (T). Contact Marathon Electric for special bearing systems, including all requirements for sleeve or roller bearing. For your discount and multiplier, contact your local Marathon Electric sales representative or local Marathon Electric Distributor. MODIFICATION/ACCESSORIES See the Modification/Accessories Sections for more information on modifications to create special motor variations. 7

4 STOCK, NON-STOCK AND BUILD UP MODELS Standard motors listed in this catalog, as indicated with a star (*) next to the catalog number, are normally in stock. There is no minimum order quantity or minimum billing charge associated with stock motors, unless stated otherwise in your quotation or agreement with Marathon Electric. Production of non-stock catalog models and all build-up models is subject to minimum order quantities or setup charges listed below Frame = 25 piece minimum Frames = 5 piece minimum or $200 set-up/model Frames = 5 piece minimum or $300 set-up/model Build-up motors must be thoroughly described at time of order, and/or associated with a formal quotation issued by Marathon Electric. Inclusion of product features for similar motors documented in this catalog should not be assumed. SERVICE For service on any Marathon Electric motor, contact your nearest Marathon Electric Authorized Service Station. For a complete listing of all domestic and foreign service stations, refer to Marathon Electric s brochure, SB112, or OPERATION AND MAINTENANCE For information on operation and maintenance, please consult the manual or card shipped with your new motor. Additional copies of Installation, Operation & Maintenance Instructions (brochure SB181) are available upon request or through our web site, STORAGE PROCEDURES In the event that long-term storage of motors is required, Marathon Electric recommends the following precautions and procedures. This information is also contained in Installation, Operation and Maintenance Instructions (SB181). A. Keep motors clean 1. Store indoors 2. Keep covered to eliminate airborne dust and dirt. 3. Cover openings for ventilation, conduit connections, etc., to prevent entry of rodents, snakes, birds and insects. B. Keep motors dry 1. Store in a dry area indoors 2. Temperature swings should be minimal to prevent condensation. 3. Space heaters are recommended to prevent condensation. 4. Treat unpainted flanges, shafts and fittings with a rust inhibitor. 5. Check insulation resistance before putting motor into service. C. Keep bearings lubricated 1. Once per month, rotate shaft several turns to distribute grease in bearings. 2. If unit has been stored more than one year, add grease before start-up (refer to lubrication procedure). DIMENSION DRAWINGS See Table of Contents for the dimension section in this catalog, or request certified drawings through your Marathon Electric Sales Engineer, Representative or local Marathon Electric Distributor. 8

5 WARRANTY Marathon Electric warrants Fractional and Integral motors to be free from defects in materials and workmanship and to conform to Marathon s written specifications. Motor Type Warranty Warranty Period from Period from Date of Date of Installation* Manufacture* Standard Warranty for any product not shown below Medium Voltage EPAct compliant (aluminum, steel & cast iron frame) Blue Chip Severe Duty Explosion Proof Blue Max, Black Max, & micromax Inverter Duty All XRI (NEMA Premium ) incl. ODP, Blue Chip, Severe Duty, Explosion Proof, etc U-Frame Automotive Duty Blue Chip IEEE * Warranty period shown is in months, and is valid for whichever period expires first. Note: Brake discs are considered a normal maintenance item and are not covered under warranty. For more information, on Marathon Electric s warranty policy, refer to the Terms and Conditions of Sale (MPN411) in the back of this catalog. SUBMITTAL DATA Mechanical and electrical submittal data is available on many stock catalog motors through our website by following the three steps listed on the next page. All other submittal data is available upon request when accompanied by a purchase order for the specified motor, subject to the following additional charges SUBMITTAL CHARGE SCHEDULE TYPE ELEMENTS NET/EA Nameplate data Motor characteristics BASIC (.PDF Performance data No-Charge format) Outline drawing External connection diagram Add for.dxf or.dwg format $25 All BASIC elements, tailored to BASIC-PLUS specific order. (.pdf format) Cut sheets of installed accessories $75 Add for.dxf or.dwg format $25 Speed/Torque curve $50 Torque capability curve $50 ADDITIONAL Commercial (end of line) test results (not ITEMS available for West Plains motors)* $50 (.pdf formats) Certificate of conformance $100 Thermal damage curve (48-326T frame) $500 + cost of additional motor Thermal damage curve (364T-6805 frame) $1500 +cost of additional motor * Does not imply retesting 9

6 1. From our homepage, click on the Motors link. From the Motors page, enter in the Marathon Catalog number or Model number. Then click on Model number in results window. (Note: If you already have a Marathon Electric motor and are looking for the performance data, make sure the model number off the nameplate is what you use for your search. Ex. 056H17T5301). 2. The Motor Model Details page will appear. You will be able to print dimensional drawings and connection diagrams in PDF format for the motors. Under the Technical Data section, click on the link, Certification Data Sheet. 3. Your results will look similar to the example shown to the right for Marathon s 1/2 HP, Black Max motor, model # 056H17T5301. It s that easy! 10

We will discuss common industrial applications with guides for the proper use of electric motors on these.

We will discuss common industrial applications with guides for the proper use of electric motors on these. INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which

More information

XRI Severe Duty 143-449T Frame. IEC Globetrotter 63-225M Frame

XRI Severe Duty 143-449T Frame. IEC Globetrotter 63-225M Frame XRI Severe Duty 143-449T Frame NEMA Premium /XRI - As a leading supplier of premium efficiency motors, we help conserve money and our environment. Marathon s designs are 100% compliant with CEE efficiency

More information

What Do All Those Things on an AC Motor Nameplate Mean?

What Do All Those Things on an AC Motor Nameplate Mean? What Do All Those Things on an AC Motor Nameplate Mean? Introduction: Ever order a motor on power, speed, and enclosure? PO says maybe "5 hp, 1,800 rpm, TEFC." New-motor nameplate says "HP 5, RPM 1748,

More information

Basic Nameplate Information

Basic Nameplate Information Basic Nameplate Information General Information: Most equipment nameplates will have some common items of information. Many of these are self explanatory, and include: Manufacturer Manufacturerʼs address

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check

More information

The Energy Independence and Security Act of 2007. The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010

The Energy Independence and Security Act of 2007. The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010 The Energy Independence and Security Act of 2007 The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010 January 23, 2009 To Our Customers, Baldor Electric Company 5711 R.S.

More information

Baldor Electric Position on DOE Small Motor Rule

Baldor Electric Position on DOE Small Motor Rule Baldor Electric Position on DOE Small Motor Rule WP0035 WP0034 Page 1 of 6 US Integral DOE Small HP Motor Rule Rule Baldor Electric Position on DOE Small Motor Rule 10/28/14 On March 9, 2010 the US Department

More information

Application Information

Application Information AGENCY LISTINGS UL and CSA Marathon Electric s Fire Pump and Explosion Proof motors are UL Listed. Other motor types are UL Recognized, including models with inherent overheating protection as noted (i.e.

More information

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor INSTALLATION, OPERATION AND MAINTENANCE MANUAL For SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor Yeomans Chicago Corporation 3905 Enterprise Court P.O. Box 6620 Aurora, IL 60598-0620 Phone:

More information

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles AC Induction Motors Simplest and most rugged electric motor Consists of wound stator and rotor assembly AC in the primary member (stator) induces current in the secondary member (rotor) Combined electromagnetic

More information

Motor Specifications. Nameplate

Motor Specifications. Nameplate Motor Specifications Nameplate The nameplate of a motor provides important information necessary for selection and application. The following drawing illustrates the nameplate of a sample 30 horsepower

More information

Baldor Electric ProSPEC MASTERFORMAT SPECIFICATION May 3, 2005. A. This specification covers integral horsepower squirrel cage AC induction motors.

Baldor Electric ProSPEC MASTERFORMAT SPECIFICATION May 3, 2005. A. This specification covers integral horsepower squirrel cage AC induction motors. SECTION 16221 - TEFC AC INDUCTION MOTORS PART 1 - GENERAL 1.1 SUMMARY A. This specification covers integral horsepower squirrel cage AC induction motors. B. This specification is intended to specify superior

More information

Rotary Phase Converters

Rotary Phase Converters FACTS from Ronk Electrical Industries, Inc. Bulletin 11981 Rotary Phase Converters ROTOVERTER Pat. No. 3,670,238 ROTO-CON Pat. No. 4,158,225 What are the ROTO-CON and ROTOVERTER power converters? The ROTO-CON

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

Introduction. Upon completion of Basics of AC Motors you should be able to:

Introduction. Upon completion of Basics of AC Motors you should be able to: Table of Contents Introduction...2 AC Motors...4 Force and Motion...6 AC Motor Construction... 12 Magnetism... 17 Electromagnetism... 19 Developing a Rotating Magnetic Field...24 Rotor Rotation...29 Motor

More information

Low Voltage Transformers Sealed, General Purpose, Dry Type

Low Voltage Transformers Sealed, General Purpose, Dry Type Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................

More information

AC Replacement for DC Mill-Duty Motors

AC Replacement for DC Mill-Duty Motors AC Replacement for DC Mill-Duty Motors This article is available online at www.aist.org for 30 days following publication. For many years, DC mill auxiliary motors for steel mill applications such as screwdowns,

More information

Specifying a Variable Frequency Drive s

Specifying a Variable Frequency Drive s Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions Installation, Operation and Maintenance Instructions for AC Induction Motors 56-6800 Frames (NEMA) 63 280 Frames (IEC) MARATHON ELECTRIC Contact Motor Customer Service at: Phone: (75) 675-33 www.marathonelectric.com

More information

The Ultimate Truck Stock Motor

The Ultimate Truck Stock Motor The Ultimate Truck Stock Motor What is a Rescue Motor? Universal Replacement Motor for Condenser Fan and Direct Drive Blower Applications Multi-Horsepower PSC Motors Flexible Mounting Options Permanent

More information

Baldor Electric Company Premium Efficiency Motor Specification Open Drip-Proof Motors 1-500 HP Rev June 6, 2001

Baldor Electric Company Premium Efficiency Motor Specification Open Drip-Proof Motors 1-500 HP Rev June 6, 2001 Table of Contents 1.0 Purpose 2.0 Scope Baldor Electric Company Premium Efficiency Motor Specification Open Drip-Proof Motors 1-500 HP Rev June 6, 2001 3.0 Motor Requirements 3.1 Applicable Codes and Regulations

More information

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

26 3213.13 Diesel Engine Driven Generators Page 1 of 6

26 3213.13 Diesel Engine Driven Generators Page 1 of 6 Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at

More information

Permanent Magnet DC Motors

Permanent Magnet DC Motors typical applications Robotics and factory automation Pick-and-place robots Positioning tables Welding wire feeders Automatic guided vehicles Barcoding equipment Computer and office equipment Copier and

More information

Baldor Electric Company Premium Efficiency Motor Specification Totally Enclosed Fan Cooled Motor 1-250 HP Rev June 6, 2001

Baldor Electric Company Premium Efficiency Motor Specification Totally Enclosed Fan Cooled Motor 1-250 HP Rev June 6, 2001 Table of Contents 1.0 Purpose 2.0 Scope Baldor Electric Company Premium Efficiency Motor Specification Totally Enclosed Fan Cooled Motor 1-250 HP Rev June 6, 2001 3.0 Motor Requirements 3.1 Applicable

More information

AC METRIC (IEC) MOTORS THREE PHASE

AC METRIC (IEC) MOTORS THREE PHASE AC METRIC MOTORS These high efficiency motors meet North American performance standards and EPACT energy efficiency mandates, and have.5 service factors. Typically used for replacement on machine tools,

More information

MasterFit. The Serviceman s Best Friend!

MasterFit. The Serviceman s Best Friend! MasterFit The Serviceman s Best Friend! MasterFit : One Motor Replaces Many Features: Energy Efficient Different Capacitor/ Speed Combinations Designed for 370V Capacitor (not furnished) Permanent Split

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

Why Baldor? Table of Contents. www.baldor.com

Why Baldor? Table of Contents. www.baldor.com Pump Motors Why Baldor? Industry s shortest lead times/flexible manufacturing. Baldor has the industry s shortest lead times on custom motors just ten working days. Our unique LEAN FLEX FLOW manufacturing

More information

TERMINAL MARKINGS AND CONNECTIONS PART WINDING START

TERMINAL MARKINGS AND CONNECTIONS PART WINDING START TERMINAL MARKINGS AND CONNECTIONS PART WINDING START NEMA NOMENCLATURE 6 LEADS 7 7 3 9 8 Delta 3 9 8 Wye OPER. 9 MODE L L L3 OPEN 7 START 3 7,8,9 T T T3 T7 T8 T9 RUN,7,8 3,9 3 8 MOTOR LEADS 3 7 Double

More information

Data Sheet. AC Industrial Electric Motors

Data Sheet. AC Industrial Electric Motors Data Pack B Issued ovember 2005 1502325812 Data Sheet AC Industrial Electric Motors Standards organisations The RS-ABB range of ac induction motors is produced to common European standards, these being

More information

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The

More information

GE Industrial Systems. AC Motor Selection and Application Guide

GE Industrial Systems. AC Motor Selection and Application Guide apple GE Industrial Systems AC Motor Selection and Application Guide TABLE OF CONTENTS Voltage... 2 Frequency... 3 Phase... 4 Motor Output Rating... 4 Polyphase Motors... 4 Single-phase Motors... 4 Service

More information

Electric Motor Brake Horsepower Calculations

Electric Motor Brake Horsepower Calculations Electric Motor Brake Horsepower Calculations By Norm Christopherson These motor calculations are contained here as they apply to the changing conditions of the blower motor when pulley adjustments are

More information

Product Brochure. Certified Mining Motors

Product Brochure. Certified Mining Motors Product Brochure Certified Mining Motors Profile Baldor Electric Company (a member of the ABB group) is a world leader in motors for the mining industry. In the continuous (24/7) operation of underground

More information

Direct drive vane axial fans. These totally enclosed/air over motors must be mounted within the airstream for proper cooling.

Direct drive vane axial fans. These totally enclosed/air over motors must be mounted within the airstream for proper cooling. Heating, Ventilating, Air Conditioning Aeration Fan, Single Phase Totally, Air Over, Rigid Base Direct drive vane axial fans. These totally enclosed/air over motors must be mounted within the airstream

More information

AC Electric Motors best practice

AC Electric Motors best practice If you want to learn more about best practice machinery maintenance, or world class mechanical equipment maintenance and installation practices, follow the link to our Online Store and see the Training

More information

Solving VFD-sourced Bearing Current Problems in AC Motors.

Solving VFD-sourced Bearing Current Problems in AC Motors. Solving VFD-sourced Bearing Current Problems in AC Motors. The 2 main sources of motor shaft voltage are: 1. Asymmetric Motor construction The stator and rotor magnetic circuits within the motor itself

More information

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:

More information

GE Industrial Systems. AC Motor Selection and Application Guide

GE Industrial Systems. AC Motor Selection and Application Guide apple GE Industrial Systems AC Motor Selection and Application Guide TABLE OF CONTENTS Voltage... 2 Frequency... 3 Phase... 4 Motor Output Rating... 4 Polyphase Motors... 6 Single-phase Motors... 9 Service

More information

Principles of Adjustable Frequency Drives

Principles of Adjustable Frequency Drives What is an Adjustable Frequency Drive? An adjustable frequency drive is a system for controlling the speed of an AC motor by controlling the frequency of the power supplied to the motor. A basic adjustable

More information

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive

More information

Industrial Control Power Transformers

Industrial Control Power Transformers Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments

More information

Miniature High-Torque, DC Servomotors and DC Gearmotors

Miniature High-Torque, DC Servomotors and DC Gearmotors typical applications Robotics Factory automation Medical equipment Computer peripherals and office equipment Portable, battery-operated equipment Textile machinery Packaging machinery Actuators Miniature

More information

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

3) What is the difference between Insulating, Isolating, and Shielded Winding transformers? Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 1) What is a transformer and how does it work? A transformer

More information

Installation Manual Version 7.3 IMPORTANT:

Installation Manual Version 7.3 IMPORTANT: Installation Manual Version 7.3 IMPORTANT: READ ENTIRE MANUAL CAREFULLY, THIS PHASE CONVERTER MUST BE INSTALLED BY A INDUSTRIAL LICENSED ELECTRICIAN 230 VOLTS MODEL ONLY READ FIRST!!!!!! DANGER: HIGH VOLTAGE

More information

Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors

Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors C-Face Kits for Field Conversion NEMA AC s Features: Complete kits with all hardware necessary for converting Baldor 56 though 449T frame ridgid base motors to C-Face mounting with base. For Baldor conversion,

More information

AC Kinetics Variable Frequency Drive Comparative Transient Inertial Testing. This document was prepared by Advanced Energy.

AC Kinetics Variable Frequency Drive Comparative Transient Inertial Testing. This document was prepared by Advanced Energy. AC Kinetics Variable Frequency Drive Comparative Transient Inertial Testing This document was prepared by Advanced Energy. December 12 th, 2014 Introduction In June of this year, AC Kinetics contacted

More information

Fundamentals of Inverter Fed Motors

Fundamentals of Inverter Fed Motors Fundamentals of Inverter Fed Motors Technical Manual 10/02 MN780 Contents Page The Growing Use Of Inverters.................................................................. 1 How Inverters Affect Motors....................................................................

More information

ADDENDUM #1(BID PACKAGE # 3)

ADDENDUM #1(BID PACKAGE # 3) H2Engineering, Inc. 114 East Fifth Avenue Tallahassee, FL 32303 Phone 850.224.7922 Fax 850.224.5876 ADDENDUM #1(BID PACKAGE # 3) To: Jeff Williams From: Peter Lindstrom Co: Leon County Date: October 04,

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Single Phase Soft Starter

Single Phase Soft Starter Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................

More information

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO) SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY

More information

Single-Phase AC Synchronous Generator

Single-Phase AC Synchronous Generator ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description

More information

300 Series PA Pump and Cooler Assemblies

300 Series PA Pump and Cooler Assemblies Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate

More information

OJ L 191, 23.7.2009, p. 26. OJ L 2, 7.1.2014, p. 1.

OJ L 191, 23.7.2009, p. 26. OJ L 2, 7.1.2014, p. 1. Table of Contents 1. Purpose of the guidelines and disclaimer... 2 1.1. The Regulations... 2 2. Scope... 2 3. Historic developments... 4 4. Scope and Requirements... 5 4.1. Scope... 5 4.2. Requirements...

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

I hope you find them useful and I would appreciate any comments or thoughts you might have for future improvements, corrections or topics.

I hope you find them useful and I would appreciate any comments or thoughts you might have for future improvements, corrections or topics. COWERN PAPERS Baldor Electric Company 5711 R.S. Boreham Jr. Street Fort Smith, AR 72901 Phone (479) 646-4711 Fax (479) 648-5792 www.baldor.com Enclosed you will find a set of papers that I have written

More information

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS D R I V E S Y S T E M S PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS The vision of Iskra Avtoelektrika is to be: One of the world's leading manufacturers of electric motors and controllers for

More information

Understanding Energy Efficient Motors

Understanding Energy Efficient Motors Understanding Energy Efficient Motors Reliable Solutions Today Introduction For anyone who specifies, buys, operates, or repairs electric motors today, the issue of motor efficiency is of growing concern

More information

Regal Beloit AC Motors

Regal Beloit AC Motors Installation, Operation and Maintenance Instructions for Industrial AC Induction Motors 140-6800 Frames (NEMA) 90 280 Frames (IEC) Regal Beloit AC Motors LEESON ELECTRIC Contact Motor Customer Service

More information

TorqPlus TM Electric Valve Actuators and Controls

TorqPlus TM Electric Valve Actuators and Controls TorqPlus TM Electric Valve Actuators and Controls Torque 150 IN/LB 600 IN/LB The Engineered Solution Bettis TorqPlus quality line of electric actuators are designed for quarter turn applications ball,

More information

DC MOTORS NEMA FRAME SCR RATED

DC MOTORS NEMA FRAME SCR RATED NEMA FRAME SCR RATED NEMA FRAME MOTORS SCR RATED High voltage permanent magnet DC motors are typically used with an SCR (thyristor) controller in applications requiring adjustable speed and constant torque

More information

PM734F - Technical Data Sheet Winding 28

PM734F - Technical Data Sheet Winding 28 - Technical Data Sheet Winding 28 SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international standards, including

More information

A1000 Cheat Sheet (Open Loop Vector)

A1000 Cheat Sheet (Open Loop Vector) A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to

More information

(3) Explosion proof. Designed to prevent ignition of any explosive gases or dust and dirt which may surround the motor.

(3) Explosion proof. Designed to prevent ignition of any explosive gases or dust and dirt which may surround the motor. ELECTRIC MOTORS Enclosures for Motors Types of motor enclosures generally used in farm applications: (1) Open type; drip proof or splash-proof. A general purpose motor for use in dry locations which are

More information

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. A Regal Brand EVERGREEN SOLUTIONS Powered by ECM Technology Upgrade/Replace PSC motors with Evergreen IM Residential/Light Commercial HVAC Systems Reduce

More information

MC1000 Series Installation and Operation Manual

MC1000 Series Installation and Operation Manual MC1000 Series Installation and Operation Manual NOTE! The manual covers software version M108314 and above. Refer to parameter 63 for the software version of the drive you are working with. If you are

More information

SPEED CONTROL SYSTEM

SPEED CONTROL SYSTEM SPEED CONTROL SYSTEM INDEX SPEED CONTROL MOTOR FEATURES 144 6W ( 70mm) 153 10W ( 70mm) 155 15W ( 80mm) 157 25W ( 80mm) 159 40W ( 90mm) 161 SPEED CONTROL W ( 90mm) 163 90W ( 90mm) 165 120W ( 90mm) 168 180W

More information

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual A Regal Brand TABLE OF CONTENTS INTRODUCTION 2 General Data 2 Initial Inspection 2 SAFETY 2 INSTALLATION 3 Location / Environment

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP ABB The Preferred Partner Egypt Cement Corporation, a major cement manufacturer, has chosen ABB wound rotor motors for all key applications

More information

Introduction. Three-phase induction motors are the most common and frequently encountered machines in industry

Introduction. Three-phase induction motors are the most common and frequently encountered machines in industry Induction Motors Introduction Three-phase induction motors are the most common and frequently encountered machines in industry - simple design, rugged, low-price, easy maintenance - wide range of power

More information

ETZGAR CONVEYOR COMPANY Controls Section v12.05

ETZGAR CONVEYOR COMPANY Controls Section v12.05 Section 7 Controls Page Description 7-1 Controls Index 7-2 Motor Data, Enclosure Rating and Abbreviations 7-3 Controls Safety Guidelines 7-4 Fixed Speed Controls Packages 7-5 Three Phase AC Variable Speed

More information

SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006

SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006 SINGLE PHASE MOTORS INSTALLATION AND MAINTENANCE MANUAL March 21, 2006 Irvine, California (800) 474-0520 Indianapolis, Indiana (800) 866-7973 Hamilton, Ontario (800) 809-0330 e-mail: sales@sterlingelectric.com

More information

IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual

IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual 7/09 MN301 Table of Contents Section 1 General Information.................................................. 1-1 Overview........................................................

More information

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80 Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022

More information

Motor Protection Voltage Unbalance and Single-Phasing

Motor Protection Voltage Unbalance and Single-Phasing Motor Protection Voltage Unbalance and Single-Phasing Cooper Bussmann contributes the following information, which is an excerpt from their 190-page handbook SPD Selecting Protective Devices Based on the

More information

543-0032-00, 943-0032-00. User s Manual

543-0032-00, 943-0032-00. User s Manual 543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and

More information

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN

More information

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24 1 X CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

REGAL-BELOIT. Installation and Operation Manual. Variable Speed AC Motor Drives. Micro and PowerWash Series

REGAL-BELOIT. Installation and Operation Manual. Variable Speed AC Motor Drives. Micro and PowerWash Series REGAL-BELOIT Variable Speed AC Motor Drives Micro and PowerWash Series Installation and Operation Manual Manual Number: SB184 TABLE OF CONTENTS 1.0 GENERAL................................................1

More information

Effective: September 10, 2006 Vermont Attachment 1 to Rule 5.500 Public Service Board Page 1 of 6

Effective: September 10, 2006 Vermont Attachment 1 to Rule 5.500 Public Service Board Page 1 of 6 Public Service Board Page 1 of 6 STANDARD APPLICATION FOR INTERCONNECTION OF GENERATION RESOURCES IN PARALLEL TO THE ELECTRIC SYSTEM OF: (Interconnecting Utility) Preamble and Instructions: An owner of

More information

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION SC ELECTROPUTERE SA SC ELECTROPUTERE SA 1. Vision, Mission, Values SC ELECTROPUTERE SA 2. LOCATION Craiova: Located in the South West of the country,

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

Three-phase AC circuits

Three-phase AC circuits Three-phase AC circuits This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit http://creativecommons.org/licenses/by/1.0/,

More information

AC Servo Motors and Servo Rated Gearheads

AC Servo Motors and Servo Rated Gearheads AC Servo Motors and Servo Rated Gearheads for the automation industry Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8)

More information

COOLING TECHNOLOGY INSTITUTE

COOLING TECHNOLOGY INSTITUTE PAPER NO: CATEGORY: TP09-18 FANS COOLING TECHNOLOGY INSTITUTE RECENT DEVELOPMENTS IN MOTOR TECHNOLOGY ALLOW DIRECT DRIVE OF LOW SPEED COOLING TOWER FANS ROBBIE MCELVEEN BILL MARTIN RYAN SMITH BALDOR ELECTRIC

More information

ICQ Series - square centrifugal

ICQ Series - square centrifugal product ICQ Square Centrifugal (TEFC) dimensions mm 280-710 poles & duty 4-8 / up to 4,500 L/s application High performance centrifugal fans for medium to high pressure ducted systems. ICQ Series The ICQ

More information

3790 en - 06.2007 / d. Alternators LSA 46.2-4 Pole. Electrical and mechanical data

3790 en - 06.2007 / d. Alternators LSA 46.2-4 Pole. Electrical and mechanical data 379 en - 6.7 / d Alternators LSA 46.2-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 46.2 alternator is designed to be suitable for typical generator applications, such

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Motor and Drives Price Book

Motor and Drives Price Book Motor and Drives Price Book Effective: 06-14-15 QUALITY STATEMENT TECO-Westinghouse Motor Company is committed to serving the needs of our customers BETTER THAN ANYONE ELSE by providing products and services

More information

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 APPROVED NO : APPROVED BY : (AUTHORIZED) SPEC.NO D600023 ISSUE DATE 08.06.1998 DAWN.

More information

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

O-I DUBI PLANT FANS Quotation Spec Data & Specifications TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement

More information

HQ Series ¼ Turn Actuator

HQ Series ¼ Turn Actuator HQ Series ¼ Turn Actuator HQ-015 thru HQ-300 Installation & Maintenance Manual HQ Series I&M Manual HQ-400-1005 1 Table of Contents: General 1.0 Actuator Mounting 2.0 External Construction 3.0 Wiring Diagrams

More information

Distribution Dry Type Transformers

Distribution Dry Type Transformers 8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg

More information

2100, 2200, 2300, 4100, 6200, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors

2100, 2200, 2300, 4100, 6200, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors 00, 00, 300, 400, 600, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors Installation, Maintenance & Parts Manual Featuring: Technology DORNER MFG. CORP. INSIDE THE USA OUTSIDE

More information

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02

More information