Instruction manual MPU analog output 4-20 ma

Size: px
Start display at page:

Download "Instruction manual MPU analog output 4-20 ma"

Transcription

1 Instruction manual MPU analog output 4-20 ma July 2012 Part no Rev. 3 Enraf B.V. P.O. Box AV Delft Netherlands Tel. : Fax : enraf-nl@honeywell.com Website : Instruction manual MPU analog output 4-20 ma Page 1

2 Copyright Enraf B.V. All rights reserved. Reproduction in any form without the prior consent of Enraf B.V. is not allowed. This manual is for information only. The contents, descriptions and specifications are subject to change without notice. Enraf B.V. accepts no responsibility for any errors that may appear in this manual. The warranty terms and conditions applicable in the country of purchase in respect to Enraf B.V. products are available from your supplier. Please retain them with your proof of purchase. Page 2 Instruction manual MPU analog output 4-20 ma

3 Preface Preface This manual is intended for technicians involved with the installation, commissioning and service of the MPU board. A description preceding the technical procedures gives the technical information necessary to understand its functioning. It is recommended to read this description prior to performing any of the procedures. Safety and prevention of damage Safe execution of the procedures in this manual requires technical experience in handling tools, and knowledge of safety regulations in handling electrical installation in hazardous environments. "Warnings", "Cautions", and "Notes" have been used throughout this manual to bring special matters to the immediate attention of the reader. A Warning concerns danger to the safety of the technician or user; A Caution draws attention to an action which may damage the equipment; A Note points out a statement deserving more emphasis than the general text, but does not deserve a "Warning" or a "Caution". The sequence of steps in a procedure may also be important from the point of view of personal safety and prevention of damage; it is therfore advised not to change the sequence of procedural steps or alter a procedure. Legal aspects The information in this manual is copyright property of Enraf B.V., Netherlands. Enraf B.V. disclaims any responsibility for personal injury or damage to equipment caused by: Deviation from any of the prescribed procedures; Execution of activities that are not prescribed; Negligence of the general safety precautions for handling tools, use of electricity and microwave radiation. Instruction manual MPU analog output 4-20 ma Page 3

4 Table of contents Table of contents Preface Introduction General MPU_II analog output Typical connection diagrams Commissioning Settings to be done for analog output operation Calibration of the analog output... 8 Appendix A Layout MPU_II board... 9 Appendix B Specifications Appendix C Overview of analog output items Appendix D ASCII table Index Page 4 Instruction manual MPU analog output 4-20 ma

5 Introduction 1 Introduction 1.1 General Enraf field instruments (854 ATG, 854 XTG, 873 SmartRadar and 877 FDI) can be equipped with a special MPU board. It is a microprocessor controlled board providing an 4-20 ma analog output which represents the level. The 4-20 ma analog output provides the gauge with a digital controlled current sink, and can be used to adapt the Enraf field instruments for control applications or analog readers and/or plotters. The analog output circuitry is completely galvanically isolated from the gauge and may be used in grounded and floating applications. The current sink is of the passive type, hence an external loop supply source must be connected. There are two versions of the MPU board in use: MPU and MPU_II. For the differences see the specifications in appendix B. 1.2 MPU_II analog output The voltage of the loop supply should be at least 12 Vdc, and may not exceed 64 Vdc (measured at the terminals of the gauge). The loop resistance is the total resistance from the loop, and hence includes supply output resistance, total cable resistance (including series resistor) and the input resistance from reader or analog input. Care should be taken that the supply voltage is high enough to prevent voltage starvation of the loop i.e. a minimum of 12 V (loop current 22 ma) should always be present. Voltages exceeding 64 V on the terminals of the MPU can damage the electronic circuitry. To reduce the dissipated power on the MPU_II inside the Enraf field instrument, an extra resistor must be wired in series with the loop in case the loop supply is higher then 36 Vdc (see figure 1.2). Figure 1.2 Supply voltage (Vdc) versus loop resistance (Ω) MPU II board It can be read from figure 1.2 that the maximum loop resistance may be 960 ohm in case the loop supply is 36 Vdc. In case the loop supply is higher then 36 Vdc the minimum extra loop resistance can be calculated with the formula: R min ext = 40 * (V loop - 36) Ω The maximum loop resistance can be calculated with the formula: R max loop = 40 * (V loop - 12) Ω Instruction manual MPU analog output 4-20 ma Page 5

6 Introduction Example: Loop supply is 55 Vdc. R min ext = 40 * (55-36) = 760 Ω R max loop = 40 * (55-12) = 1720 Ω If a resistor of 820 ohm is wired in the loop, the remaining loop resistance may be maximal: = 900 Ω. 1.3 Typical connection diagrams Page 6 Instruction manual MPU analog output 4-20 ma

7 Commissioning 2 Commissioning 2.1 Settings to be done for analog output operation Refer to appendix C for relevant analog output items. After installing the Enraf field instrument, the analog output option must be set for the level range. Connect the analog loop to the grey terminals marked '1' and '2'. (see section 1.2.2). The positive lead must be connected to terminal 1 and the negative lead to terminal 2. First the proper working of the analog output must be checked: Check the contents of items [A3] and [A4] (the correct factory calibrated values are noted on the safety barrier of the MPU). If necessary refer to section 2.2 'Calibration of the analog output'. Enter protection level 1 (W1=ENRAF1). Set item [AK] to 'O'. The result will be that a current can manually be overwritten via the PET 847 keyboard. Issue item [EX] to exit protection level 1. Set item [PO] to 'J' (PO=J) to show the analog output current on the display of the PET 847. After disconnecting the PET 847 from the Enraf field instrument item [PO] will be reset. ANAL OUT --OENV E+00 ma The '--OENV' indicates an output error because no overwrite value is available. Now an overwrite value can be entered with item [AF], which will result in a current flowing in the output circuit. - Enter a current of 4 ma (AF= E+01) and check reading on the PET display and the contents of item [EA] (content of EA should be 2200). ANAL OUT ----OV E+01 ma Also the voltage on the gauge terminals can be measured: Enter [AV] and wait approximately 20 seconds; set voltage pointer to (VP=10.07). Enter item [VV]: the Enraf field instrument will respond with the voltage on the gauge terminals (must be in range E+02 < VV < E+02). - Enter a current of 22 ma (AF= E+02) and check reading on the PET display and the contents of item [EA] (content of EA should be 2200). ANAL OUT ----OV E+02 ma Also the voltage on the gauge terminals can be measured: Enter [AV] and wait approximately 20 seconds; set voltage pointer to (VP=10.07). Enter item [VV]: the Enraf field instrument will respond with the voltage on the gauge terminals (must be in range E+02 < VV < E+02) Instruction manual MPU analog output 4-20 ma Page 7

8 Commissioning If the analog output functions correct the analog output current can be set for a certain level range as follows: Enter protection level 1 (W1=ENRAF1). Program item [AK] according the mode you want to operate the analog output. See description of item [AK] in appendix C. Program item [AM] with the level which belongs to an analog output current of 4 ma. Program item [AN] with the level which belongs to an analog output current of 20 ma. Issue item [EX] to exit protection level 1. The Enraf field instrument will initialize which activates the new entered parameters. 2.2 Calibration of the analog output Calibration of the analog output current signal can only be done in the workshop. This because an external power supply and a digital ma meter must be connected to the Enraf field instrument. Calibration procedure: Connect a Vdc power supply and a digital current meter to the terminal 1 and 2. The digital current meter should have an accuracy better than 10 ma. Enter protection level 1 (W1=ENRAF1). Issue command item [A5]. A current of approximately 4 ma will flow in the output circuit. Enter the exact reading of the digital current meter in item [A3] (A3=+.xxxxxxxxE+xx). Example: current of 4,02 ma must be entered as A3= E+01. Issue command item [A6]. A current of approximately 18 ma will flow in the output circuit. Enter the exact reading of the digital current meter in item [A4] (A4=+.xxxxxxxxE+xx). Example: current of 17,99 ma must be entered as A4= E+02. Set item [AK] to 'O'. The result will be that a current can be entered manually via the PET 847 keyboard. Issue item [EX] to exit protection level 1. Now an overwrite value can be entered with item [AF], which will result in a current flowing in the output circuit. Check with the digital current meter the accuracy of the loop current at several settings in the range of 4-20 ma. Readings of the current meter and the overwrite setting of the level gauge may not differ more than 12 ma. Write the new values for item [A3] and [A4] on the reserved space on the safety barrier. Page 8 Instruction manual MPU analog output 4-20 ma

9 Appendix A Appendix A Layout MPU_II board MPU_II board for 854 ATG, 873 SmartRadar and 877 FDI MPU_II board for 854 XTG Instruction manual MPU analog output 4-20 ma Page 9

10 Appendix B Appendix B Specifications MPU analog output Valid for the MPU board with number (this number is printed on the board). Type : full galvanic isolated passive 4-20 ma current sink Maximum terminal voltage (no load) : 24 Vdc Minimum terminal voltage (@ 25 ma) : 12.5 Vdc Maximum loop resistance : 575 Ω max. (see figure 1.1) Minimum output current : 3.5 ma Maximum output current : 22 ma current resolution : 6 ma (12 bits) level resolution : 0.1 mm or 1/1000 ft (854 ATG) current un-accuracy : < 0.1% Full Scale (25 ma) Minimum level range : > 0 m Maximum level range : 27 m (854 ATG) Galvanic isolation type : opto-isolator DC isolation (1 min.) : 10 kvdc Surge protection : 350 V Reverse polarity protection : yes Update rate : approx. once per 4 sec. Calibration : electronically (via software) Care should be taken that the supply voltage is high enough to prevent voltage starvation of the loop i.e. a minimum of 12.5 V (loop current 22 ma) should always be present. Voltages exceeding 24 V on the terminals of the MPU can damage the electronic circuitry. Caution The analog output current (level) will not be effected by a power-down of the gauge. Therefore the analog loop supply must be fed by the same mains as used for the Enraf field instrument, and the analog output current signal must be switched with the same switch as used for the mains of the Enraf field instrument. Page 10 Instruction manual MPU analog output 4-20 ma

11 Appendix B MPU_II analog output Valid for the MPU_II board with number (this number is printed on the board). A watchdog is implemented to check if the MPU_II board with analog output is still alive. If the MPU_II board is not alive it takes about 10 seconds to decrease the output current to about 2 ma. Type : full galvanic isolated passive 4-20 ma current sink Maximum terminal voltage (no load) : 64 Vdc (with additional loop-resistor) see figure 1.2 Minimum terminal voltage (@ 25 ma) : 12 Vdc Maximum loop resistance : 960 Ω max (loop voltage 36 Vdc) see figure 1.2 Minimum output current : 3.5 ma Maximum output current : 22 ma current resolution : 6 ma (12 bits) level resolution : 0.1 mm or 1/1000 ft (854 ATG) current un-accuracy : < 0.1% Full Scale (25 ma) Minimum level range : > 0 m Maximum level range : 27 m (854 ATG) Galvanic isolation type : opto-isolator DC isolation (1 min.) : 10 kvdc (Opto coupler) Surge protection : 300 V (gas arrestor) Reverse polarity protection : yes Update rate : approx. once per second Calibration : electronically (via software) Instruction manual MPU analog output 4-20 ma Page 11

12 Appendix C Appendix C Overview of analog output items For service purposes like calibration and setting the Enraf field instrument can be controlled via the infra-red communication port via the PET 847. All readings, settings and calibrations are done via so called items. All parameters necessary to program the analog output can be done after entering protection level 1. This is done by typing W1=ENRAF1 in which ENRAF1 is the factory programmed default password for level 1. The [EX] command should be given to exit protection level 1. Item summary In this appendix relevant items for the analog output option are mentioned. User items Item AM AN AK Description Level value which corresponds with current 4 ma Level value which corresponds with current 20 ma Operation mode analog output Service items Item A3 A4 A5 A6 AF AO AQ AV EA VP VV Description Analog output current (4 ma) Analog output current (18 ma) Set analog output current to 4 ma Set analog output current to 18 ma Overwrite analog output current Analog output current value Analog output status Analog voltage measurement command Error analog output request Voltage pointer Voltage value Page 12 Instruction manual MPU analog output 4-20 ma

13 Appendix C Analog output item descriptions Item : A3, A4 Analog output calibration value Entry format : 14 ASCII characters Default value : E+00 These items are used to calibrate the analog output of the MPU. The correct value for [A3] is obtained by sending command item [A5] after which the current output (approximately 4 ma) is measured with a digital ma meter. The measured value must be programmed in item [A3]. The correct value for [A4] is obtained by sending command item [A6] after which the current output (approximately 18 ma) is measured with a digital ma meter. The measured value must be programmed in item [A4]. Item : A5, A6 Analog output calibration command Default value : not applicable These command items are used to calibrate the analog output of the MPU. See item description for items [A3] and [A4]. Item : AF Analog output overwrite Entry format : 14 ASCII characters Default value : not applicable With this item the user can manually overwrite the current output. The item [AK] must be set to overwrite mode. See items [AK], [AO] and [AQ]. Instruction manual MPU analog output 4-20 ma Page 13

14 Appendix C Item : AK Analog output mode Entry format : 1 ASCII character Default value : D Via this item is selected under what conditions the analog output current will operate. [AK] [AL] V Valid level I Invalid level F Level fail T Time-out Start-up D Analog output disabled (default setup value) O Io = [AF] (Overwrite mode) Io = 3.5 ma (during start-up) P Io = [AF] (Overwrite mode) Io = 22 ma (during start-up) L Io = [AL] Io = [LV] no [LV]:Io=3.5 ma Io = 3.5 ma M Io = [AL] Io = [LV] no [LV]:Io=22 ma Io = 22 ma A Io = [AL] Io = 3.5 ma B Io = [AL] Io = 22 ma I Io = [AL] Io = 3.5 ma J Io = [AL] Io = 22 ma [AF] = Analog output overwrite value [AL] = Actual level [LV] = Last Valid level Io = Output current Note: 3.5 ma <= Io <= 22 ma Item : AM Analog 4 ma level Entry format : according to item LD Default value : according to item LD This item must be programmed with the level value which corresponds with an output current of 4 ma. Item : AN Analog 20 ma level Entry format : according to item LD Default value : according to item LD This item must be programmed with the level value which corresponds with an output current of 20 ma. Item : AO Actual analog output current Default value : not applicable The level gauge will respond with the actual current value. In this way the actual current can be checked. Refer to item [AQ] for the analog output status bytes. Page 14 Instruction manual MPU analog output 4-20 ma

15 Appendix C Item : AQ Actual analog output status Default value : not applicable This item reflects the status of the analog output. The reply of the level gauge consists out of one ASCII character which must be decoded into bits (see appendix D: ASCII table). Bit b4 represents the analog output value status: Analog output value status (bit b4) Output status (bit b3 upto b0) b6 b5 b4 b3 b2 b1 b0 1 0 vs os3 os2 os1 os0 [AQ] b4 Analog output value 0 Output current in 4 to 20 ma range P,Q..._ 1 Output current out of 4 to 20 ma range Level control: General output fail: Analog output disable: Overwrite mode: Calibration mode: [AQ] b3,b2,b1,b0 Analog output status 0000 Valid product level used L,M,A,B,I,J A,Q 0001 Last valid product level used L,M B,R 0010 Invalid level used A,B C,S 0011 No valid product level available I,J D,T 0100 No last valid product level available L,M E,U 0101 No level available A,B F,V 0110 Level time-out L,M,A,B,I,J G,W 0111 Invalid level I,J H,X 1000 Level failure A,B,I,J [AQ] b3,b2,b1,b0 Analog output status [AK] I,Y 1001 Analog output general failure not set [AQ] b3,b2,b1,b0 Analog output status [AK] J,Z 1010 Analog output disabled D [AQ] b3,b2,b1,b0 Analog output status [AK] K,[ 1011 Overwrite value used O,P L,\ 1100 No overwrite value available O,P [AQ] b3,b2,b1,b0 Analog output status [AK] M,] 1101 Calibration mode entered L,M,A,B,I,J [AQ] b3,b2,b1,b0 N,^ 1110 not used O,_ 1111 not used Instruction manual MPU analog output 4-20 ma Page 15

16 Appendix C Item : AV Measure analog voltage command Default value : not applicable This item gives a command to the MPU to measure several analog test voltages. The measured voltages can be read via items [VP] and [VV]. Item : EA Analog output error request Default value : 2200 As reply to this item the most recent encountered error by the MPU will be echoed. Possible errors EA Error description 2200 No error, value at initialisation 2210 Vdac error /2 Vdac - offset error 2212 Vdac - offset error 2213 Vloop error (Vloop not in the range Vdc) 2215 Analog output not calibrated ([A3] and/or [A4] are zero, MPU analog output not operational Item : VP Voltage pointer Entry format : 5 ASCII characters Default value : Via this item a voltage pointer is set. The measured voltage (item [AV]) of this pointer can be read via requesting item [VV]. VP Selected voltage pointer Vdac /2 Vdac - offset Vdac - offset Vloop (must be in the range 11,5 to 28 Vdc) Note: A certain delay between loading the voltage pointer (item [VP]) and the value request (item [VV]) should be kept. This to allow the FPU to do the necessary calculations. Item : VV Voltage value Default value : Via this item the voltage value can be requested of the voltage pointer set with item [VP]. Note: A certain delay between loading the voltage pointer (item [VP]) and the value request (item [VV]) should be kept. This to allow the FPU to do the necessary calculations. Page 16 Instruction manual MPU analog output 4-20 ma

17 Appendix D Appendix D ASCII table HEX MSB BIT LSB NUL DLE SP P p SOH DC1! 1 A Q a q STX DC2 2 B R b r ETX DC3 # 3 C S c s EOT DC4 $ 4 D T d t ENQ NAK % 5 E U e u ACK SYN & 6 F V f v BEL ETB 7 G W g w BS CAN ( 8 H X h x HT EM ) 9 I Y i y A LF SUB * : J Z j z B VT ESC + ; K [ k { C FF FS < L \ l l D CR GS - = M ] m } E SO RS. > N ^ n ~ F SI US /? O - o DEL Instruction manual MPU analog output 4-20 ma Page 17

18 Index Index 847 PET... 7, 12 Calibration... 8 Caution... 3 Commissioning... 7 Connection diagrams... 6 Item A A A A AF AK AM AN AO AQ AV EA VV Loop resistance... 5, 10 MPU analog output MPU_II analog output... 5, 11 Note... 3 Protection level , 8, 12 Service items Specifications Supply voltage... 5, 10 User items Warning... 3 Page 18 Instruction manual MPU analog output 4-20 ma

19 Notes Instruction manual MPU analog output 4-20 ma Page 19

20 Notes Page 20 Instruction manual MPU analog output 4-20 ma

Instruction manual Spot temperature and Analog output options for 854 servo, 97x SmartRadar and 877 FDI

Instruction manual Spot temperature and Analog output options for 854 servo, 97x SmartRadar and 877 FDI Instruction manual Spot temperature and Analog output options for 854 servo, 97x SmartRadar and 877 FDI June 22 Part no. 446.644 Revision 5 Enraf B.V. P.O. Box 82 26 AV Delft Netherlands Tel. : +3 5 27

More information

Voyager 9520/40 Voyager GS9590 Eclipse 5145

Voyager 9520/40 Voyager GS9590 Eclipse 5145 Voyager 9520/40 Voyager GS9590 Eclipse 5145 Quick Start Guide Aller à www.honeywellaidc.com pour le français. Vai a www.honeywellaidc.com per l'italiano. Gehe zu www.honeywellaidc.com für Deutsch. Ir a

More information

BARCODE READER V 2.1 EN USER MANUAL

BARCODE READER V 2.1 EN USER MANUAL BARCODE READER V 2.1 EN USER MANUAL INSTALLATION OF YOUR DEVICE PS-2 Connection RS-232 Connection (need 5Volts power supply) 1 INSTALLATION OF YOUR DEVICE USB Connection 2 USING THIS MANUAL TO SETUP YOUR

More information

Xi2000 Series Configuration Guide

Xi2000 Series Configuration Guide U.S. Default Settings Sequence Reset Scanner Xi2000 Series Configuration Guide Auto-Sense Mode ON UPC-A Convert to EAN-13 OFF UPC-E Lead Zero ON Save Changes POS-X, Inc. 2130 Grant St. Bellingham, WA 98225

More information

plc numbers - 13.1 Encoded values; BCD and ASCII Error detection; parity, gray code and checksums

plc numbers - 13.1 Encoded values; BCD and ASCII Error detection; parity, gray code and checksums plc numbers - 3. Topics: Number bases; binary, octal, decimal, hexadecimal Binary calculations; s compliments, addition, subtraction and Boolean operations Encoded values; BCD and ASCII Error detection;

More information

ASCII Code. Numerous codes were invented, including Émile Baudot's code (known as Baudot

ASCII Code. Numerous codes were invented, including Émile Baudot's code (known as Baudot ASCII Code Data coding Morse code was the first code used for long-distance communication. Samuel F.B. Morse invented it in 1844. This code is made up of dots and dashes (a sort of binary code). It was

More information

Memory is implemented as an array of electronic switches

Memory is implemented as an array of electronic switches Memory Structure Memory is implemented as an array of electronic switches Each switch can be in one of two states 0 or 1, on or off, true or false, purple or gold, sitting or standing BInary digits (bits)

More information

Model 200 / 250 / 260 Programming Guide

Model 200 / 250 / 260 Programming Guide Model 200 / 250 / 260 Programming Guide E-SEEK Inc. R & D Center 9471 Ridgehaven Court #E San Diego, CA 92123 Tel: 858-495-1900 Fax: 858-495-1901 Sales & Marketing 245 Fischer Ave #D5 Costa Mesa, CA 92626

More information

DL910 SERIES. Instruction Manual

DL910 SERIES. Instruction Manual DL910 SERIES Instruction Manual DL910 SERIES INSTRUCTION MANUAL ALL RIGHTS RESERVED Datalogic reserves the right to make modifications and improvements without prior notification. Datalogic shall not

More information

BI-300. Barcode configuration and commands Manual

BI-300. Barcode configuration and commands Manual BI-300 Barcode configuration and commands Manual 1. Introduction This instruction manual is designed to set-up bar code scanner particularly to optimize the function of BI-300 bar code scanner. Terminal

More information

URL encoding uses hex code prefixed by %. Quoted Printable encoding uses hex code prefixed by =.

URL encoding uses hex code prefixed by %. Quoted Printable encoding uses hex code prefixed by =. ASCII = American National Standard Code for Information Interchange ANSI X3.4 1986 (R1997) (PDF), ANSI INCITS 4 1986 (R1997) (Printed Edition) Coded Character Set 7 Bit American National Standard Code

More information

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential

More information

Part No. : MUL-53221-07 PROGRAMMING GUIDE

Part No. : MUL-53221-07 PROGRAMMING GUIDE Part No. : MUL-53221-07 PROGRAMMING GUIDE PROGRAMMING GUIDE for BARCODE SCANNERS The guide can be used as keyboard emulation, RS- 232C serial interface, and USB 1.1 interface and wand emulation. IMPORTANT

More information

Numeral Systems. The number twenty-five can be represented in many ways: Decimal system (base 10): 25 Roman numerals:

Numeral Systems. The number twenty-five can be represented in many ways: Decimal system (base 10): 25 Roman numerals: Numeral Systems Which number is larger? 25 8 We need to distinguish between numbers and the symbols that represent them, called numerals. The number 25 is larger than 8, but the numeral 8 above is larger

More information

ESPA 4.4.4 Nov 1984 PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION

ESPA 4.4.4 Nov 1984 PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION 2.1 CHARACTER STRUCTURE 2.2 THE CHARACTER SET 2.3 CONTROL CHARACTERS 2.3.1 Transmission control

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

Create!form Barcodes. User Guide

Create!form Barcodes. User Guide Create!form Barcodes User Guide Barcodes User Guide Version 6.3 Copyright Bottomline Technologies, Inc. 2008. All Rights Reserved Printed in the United States of America Information in this document is

More information

Command Emulator STAR Line Mode Command Specifications

Command Emulator STAR Line Mode Command Specifications Line Thermal Printer Command Emulator STAR Line Mode Command Specifications Revision 0.01 Star Micronics Co., Ltd. Special Products Division Table of Contents 1. Command Emulator 2 1-1) Command List 2

More information

The ASCII Character Set

The ASCII Character Set The ASCII Character Set The American Standard Code for Information Interchange or ASCII assigns values between 0 and 255 for upper and lower case letters, numeric digits, punctuation marks and other symbols.

More information

Barcode Magstripe. Decoder & Scanner. Programming Manual

Barcode Magstripe. Decoder & Scanner. Programming Manual Barcode Magstripe Decoder & Scanner Programming Manual CONTENTS Getting Started... 2 Setup Procedures... 3 Setup Flow Chart...4 Group 0 : Interface Selection... 5 Group 1 : Device Selection for keyboard

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2. SIMATIC ET 200S distributed I/O SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Manual 04/2007 A5E01077385-01 Safety Guidelines

More information

User Manual. AS-Interface Programmer

User Manual. AS-Interface Programmer AS-Interface Programmer Notice: RESTRICTIONS THE ZMD AS-INTERFACE PROGRAMMER HARDWARE AND ZMD AS-INTERFACE PROGRAMMER SOFTWARE IS DESIGNED FOR IC EVALUATION, LABORATORY SETUP AND MODULE DEVELOPMENT ONLY.

More information

Barcode Scanning Made Easy. Programming Guide

Barcode Scanning Made Easy. Programming Guide Barcode Scanning Made Easy Programming Guide CCD Scanner Programming Guide Please Read Note: The Wasp WCS3900 Series Scanners are ready to scan the most popular barcodes out of the box. This manual should

More information

Chapter 1. Binary, octal and hexadecimal numbers

Chapter 1. Binary, octal and hexadecimal numbers Chapter 1. Binary, octal and hexadecimal numbers This material is covered in the books: Nelson Magor Cooke et al, Basic mathematics for electronics (7th edition), Glencoe, Lake Forest, Ill., 1992. [Hamilton

More information

BAR CODE 39 ELFRING FONTS INC.

BAR CODE 39 ELFRING FONTS INC. ELFRING FONTS INC. BAR CODE 39 This package includes 18 versions of a bar code 39 font in scalable TrueType and PostScript formats, a Windows utility, Bar39.exe, that helps you make bar codes, and Visual

More information

DEBT COLLECTION SYSTEM ACCOUNT SUBMISSION FILE

DEBT COLLECTION SYSTEM ACCOUNT SUBMISSION FILE CAPITAL RESOLVE LTD. DEBT COLLECTION SYSTEM ACCOUNT SUBMISSION FILE (DCS-ASF1107-7a) For further technical support, please contact Clive Hudson (IT Dept.), 01386 421995 13/02/2012 Account Submission File

More information

CHAPTER 8 BAR CODE CONTROL

CHAPTER 8 BAR CODE CONTROL CHAPTER 8 BAR CODE CONTROL CHAPTER 8 BAR CODE CONTROL - 1 CONTENTS 1. INTRODUCTION...3 2. PRINT BAR CODES OR EXPANDED CHARACTERS... 4 3. DEFINITION OF PARAMETERS... 5 3.1. Bar Code Mode... 5 3.2. Bar Code

More information

This is great when speed is important and relatively few words are necessary, but Max would be a terrible language for writing a text editor.

This is great when speed is important and relatively few words are necessary, but Max would be a terrible language for writing a text editor. Dealing With ASCII ASCII, of course, is the numeric representation of letters used in most computers. In ASCII, there is a number for each character in a message. Max does not use ACSII very much. In the

More information

Sierra S-Series Smart Interface Software User Manual

Sierra S-Series Smart Interface Software User Manual Sierra S-Series Smart Interface Software User Manual Part Number IM-SIP 08/99 Revision B 5 Harris Court, Building L Monterey, CA 93940 (831) 373-0200 (800) 866-0200 Fax (831) 373-4402 http://www.sierrainstruments.com

More information

Bar Code CCD Scanner OPERATION MANUAL

Bar Code CCD Scanner OPERATION MANUAL ISO 9002 Certified Lead with technology Win customers with service Bar Code CCD Scanner OPERATION MANUAL 69 Jarltech International Inc. 1998. All rights reserved. Under the copyright laws, this manual

More information

Barcode Scanning Made Easy. WWS500 Programming Guide

Barcode Scanning Made Easy. WWS500 Programming Guide Barcode Scanning Made Easy WWS500 Programming Guide Table of Contents Chapter 1. Introduction...........................2 Chapter 2. Barcode Symbologies...................3 Chapter 3. Quick Start............................4

More information

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations Addendum to: IMPULSE G+ Series 3 Manual (140-10258) IMPULSE VG+ Series 3 Manual (140-10257) This addendum should be used when a 24VDC

More information

MK-SERIE 1000/1500/2000 AllOfBarcode.de Michael Krug - 83278Traunstein BARCODE SCANNER

MK-SERIE 1000/1500/2000 AllOfBarcode.de Michael Krug - 83278Traunstein BARCODE SCANNER MK-SERIE 1000/1500/2000 AllOfBarcode.de Michael Krug - 83278Traunstein BARCODE SCANNER Configuration Guide - 1 - Table of Contents Chapter 1 System Information 1.1 About this manual 3 1.2 How to set up

More information

Chapter 5. Binary, octal and hexadecimal numbers

Chapter 5. Binary, octal and hexadecimal numbers Chapter 5. Binary, octal and hexadecimal numbers A place to look for some of this material is the Wikipedia page http://en.wikipedia.org/wiki/binary_numeral_system#counting_in_binary Another place that

More information

Entis Pro for Windows 7 OPC Server

Entis Pro for Windows 7 OPC Server Entis Pro for Windows 7 OPC Server Copyright 2001-2011 Enraf BV, All rights reserved. Reproduction in any form without the prior consent of Enraf B.V. is not allowed. This manual is for information only.

More information

MIDECO 64-outputs MIDI note decoder USER MANUAL. Roman Sowa 2012

MIDECO 64-outputs MIDI note decoder USER MANUAL. Roman Sowa 2012 MIDECO 64-outputs MIDI note decoder USER MANUAL Roman Sowa 2012 www.midi-hardware.com 1.Overview Thank you for choosing MIDECO as your new MIDI-to-digital converter. This short manual will guide you through

More information

S302D. Programming Guide. 2D Imaging Barcode Scanner. Advanced Handheld High-Speed Laser Scanner

S302D. Programming Guide. 2D Imaging Barcode Scanner. Advanced Handheld High-Speed Laser Scanner S302D 2D Imaging Barcode Scanner Programming Guide 1 Advanced Handheld High-Speed Laser Scanner Revision History Changes to the original manual are listed below: Version Date Description of Version 1.0

More information

Allen-Bradley/Rockwell

Allen-Bradley/Rockwell MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:

More information

ASCII CODES WITH GREEK CHARACTERS

ASCII CODES WITH GREEK CHARACTERS ASCII CODES WITH GREEK CHARACTERS Dec Hex Char Description 0 0 NUL (Null) 1 1 SOH (Start of Header) 2 2 STX (Start of Text) 3 3 ETX (End of Text) 4 4 EOT (End of Transmission) 5 5 ENQ (Enquiry) 6 6 ACK

More information

3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES

3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES 12.02 EA 4035-SERIES 3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES Splashproof 35,1x22,4 mm FEATURES * IP65 * 2 LED AND 2 LCD TYPES * EASY TO USE OR COMPATIBLE TO DATEL * ±200mV D.C. FULL SCALE READING

More information

MINIMAG. Magnetic Stripe Reader Keyboard Wedge. User s Manual

MINIMAG. Magnetic Stripe Reader Keyboard Wedge. User s Manual MINIMAG Magnetic Stripe Reader Keyboard Wedge User s Manual TM Agency Approved Specifications for subpart B of part 15 of FCC rule for a Class A computing device. Limited Warranty ID TECH warrants to the

More information

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134 AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN SP1134 Power and productivity for a better world TM AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN NOTICE This document contains information

More information

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections

More information

RGB for ZX Spectrum 128, +2, +2A, +3

RGB for ZX Spectrum 128, +2, +2A, +3 RGB for ZX Spectrum 128, +2, +2A, +3 Introduction... 2 Video Circuitry... 3 Audio Circuitry... 8 Lead Wiring... 9 Testing The Lead... 11 Spectrum +2A/+3 RGB Differences... 12 Circuitry Calculations...

More information

MSR605. Programmer s Manual. Magnetic Stripe Card Reader/Writer (High & Low Coercivity) Revision B 2009-06-01

MSR605. Programmer s Manual. Magnetic Stripe Card Reader/Writer (High & Low Coercivity) Revision B 2009-06-01 MSR605 Magnetic Stripe Card Reader/Writer (High & Low Coercivity) Programmer s Manual Revision B 009-06-0 0 Table of Contents SECTION INTRODUCTION...... Accessories of MSR605...... Warranty...... SECTION

More information

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1

More information

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves

More information

TELOCATOR ALPHANUMERIC PROTOCOL (TAP)

TELOCATOR ALPHANUMERIC PROTOCOL (TAP) TELOCATOR ALPHANUMERIC PROTOCOL (TAP) Version 1.8 February 4, 1997 TABLE OF CONTENTS 1.0 Introduction...1 2.0 TAP Operating Environment...1 3.0 Recommended Sequence Of Call Delivery From An Entry Device...2

More information

The Answer to the 14 Most Frequently Asked Modbus Questions

The Answer to the 14 Most Frequently Asked Modbus Questions Modbus Frequently Asked Questions WP-34-REV0-0609-1/7 The Answer to the 14 Most Frequently Asked Modbus Questions Exactly what is Modbus? Modbus is an open serial communications protocol widely used in

More information

MTS Master Custom Communications Protocol APPLICATION NOTES

MTS Master Custom Communications Protocol APPLICATION NOTES MTS Master Custom Communications Protocol APPLICATION NOTES Rev. 0 12/6/94 Contents INTRODUCTION... 1 ACCOL TERMINAL ASSIGNMENTS... 1 MTS PROTOCOL SIGNAL LIST... 2 COMMUNICATIONS INTERFACE... 3 Line Parameter

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation

More information

BRMO 80 / ETH-IP. User Manual. Réf : MU-BRMO 80-ETH-IP-1.4-EN

BRMO 80 / ETH-IP. User Manual. Réf : MU-BRMO 80-ETH-IP-1.4-EN User Manual Réf : MU-BRMO 80-ETH-IP-1.4-EN BALOGH SA 189, rue d Aubervilliers - C.P. 97 75886 PARIS Cedex 18 France Tél : 33 (0)1 44 65 65 00 Fax : 33 (0)1 44 65 65 10 e-mail : balogh@balogh-group.com

More information

T0118 T2118 T3118. Instruction Manual

T0118 T2118 T3118. Instruction Manual Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity

More information

DC DC CONVERTER 1000W 100-400VDC Input / 12VDC Output

DC DC CONVERTER 1000W 100-400VDC Input / 12VDC Output DC DC CONVERTER 1000W 100-400VDC Input / 12VDC Output Code prod. : 30x57090.00 Feb, 11 th 2005 MES DEA s.a. - Service - Copying of this document and giving it to others and the use or communication of

More information

EXTERNAL DIMENSIONS AND PARTS

EXTERNAL DIMENSIONS AND PARTS FX2N-4DA SPECIAL FUNCTION BLOCK USER S GUIDE JY992D65901A This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4DA special

More information

HANDHELD LASER SCANNER

HANDHELD LASER SCANNER HANDHELD LASER SCANNER PROGRAMMING GUIDE PSC Scanning, Inc. En Suisse: 959 Terry Street GOMARO s.a. Eugene, Oregon 97402-9120 1123 Aclens - Switzerland Telephone: (541) 683-5700 http://www.gomaro.ch/ Toll

More information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850

More information

12 Volt 30 Amp Digital Solar Charge Controller

12 Volt 30 Amp Digital Solar Charge Controller 12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

Scanner Configuration

Scanner Configuration Scanner Configuration SmartScan Manual DOC Version 2.21 This document is specifically designed for the user to print two pages per sheet of paper with optimal print quality. Copyright 2005~ 2008 CIPHERLAB

More information

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20 Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation

More information

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim Automotive sensor simulator Operating manual AutoSim Contents Introduction.. page 3 Technical specifications.... page 4 Typical application of AutoSim simulator..... page 4 Device appearance... page 5

More information

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB Drives. User s Manual HTL Encoder Interface FEN-31 ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510

User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510 User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

Digital To Analog Converter with Sine Wave Output

Digital To Analog Converter with Sine Wave Output Digital To Analog Converter with Sine Wave Output Overview In this Lab we will build a resistive ladder network and use the BASIC Stamp to generate the digital data for the D/A conversions. PBASIC will

More information

Measuring Resistance Using Digital I/O

Measuring Resistance Using Digital I/O Measuring Resistance Using Digital I/O Using a Microcontroller for Measuring Resistance Without using an ADC. Copyright 2011 John Main http://www.best-microcontroller-projects.com Page 1 of 10 Table of

More information

WD-AMX Water Detection Controllers

WD-AMX Water Detection Controllers Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation

More information

IO-DIM6 6-Channel, Digital to Analogue Converters

IO-DIM6 6-Channel, Digital to Analogue Converters Page 1 of 6 IO-DIM6 6-Channel, Digital to Analogue Converters Features: Benefits: Input status indication Calibrated output DIN Rail mounting Expands controller input capacity Fault finding LED indication

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Part Number Description Packages available

Part Number Description Packages available Features 3 digital I/O Serial Data output Connects directly to RF Modules Easy Enc / Dec Pairing Function Minimal External Components Required Performs all encoding/decoding of data for Reliable Operation.

More information

Bar Code Reader Models 1000/1002 USER'S MANUAL 2190 Regal Parkway Euless, TX 76040 (817) 571-9015 (800) 648-4452 FAX (817) 685-6232 FCC NOTICE WARNING: This equipment generates, uses and can radiate radio

More information

NortechCommander Software Operating Manual MAN-00004 R6

NortechCommander Software Operating Manual MAN-00004 R6 NortechCommander Software Operating Manual MAN-00004 R6 If the equipment described herein bears the symbol, the said equipment complies with the applicable European Union Directive and Standards mentioned

More information

Transmitter Interface Program

Transmitter Interface Program Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following

More information

Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual

Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position

More information

Allen-Bradley. Bar Code. 2-D Hand-Held. Programming Guide. Bar Code. Scanners. (Cat. No. 2755-HTG-4)

Allen-Bradley. Bar Code. 2-D Hand-Held. Programming Guide. Bar Code. Scanners. (Cat. No. 2755-HTG-4) Allen-Bradley 2-D Hand-Held Bar Code Scanners Bar Code Programming Guide (Cat. No. 2755-HTG-4) Important User Information The illustrations, charts, sample programs and layout examples shown in this guide

More information

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

Option field bus: without bus with profibus DP. Design-Index (Subject to change) Amplifier / controller cards ED1 Digital amplifier / controller card ED1 for 1 or 2 proportional solenoids 4 analogue inputs, of which 2 for differential inputs 8 digital inputs Card setting via PC, multi-function

More information

PACKAGE OUTLINE DALLAS DS2434 DS2434 GND. PR 35 PACKAGE See Mech. Drawings Section

PACKAGE OUTLINE DALLAS DS2434 DS2434 GND. PR 35 PACKAGE See Mech. Drawings Section PRELIMINARY DS2434 Battery Identification Chip FEATURES Provides unique ID number to battery packs PACKAGE OUTLINE Eliminates thermistors by sensing battery temperature on chip DALLAS DS2434 1 2 3 256

More information

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide Sensors LCD Real Time Clock/ Calendar DC Motors Buzzer LED dimming Relay control I2C-FLEXEL PS2 Keyboards Servo Motors IR Remote Control

More information

www.jameco.com 1-800-831-4242

www.jameco.com 1-800-831-4242 Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. LF411 Low Offset, Low Drift JFET Input Operational Amplifier General Description

More information

MODULE BOUSSOLE ÉLECTRONIQUE CMPS03 Référence : 0660-3

MODULE BOUSSOLE ÉLECTRONIQUE CMPS03 Référence : 0660-3 MODULE BOUSSOLE ÉLECTRONIQUE CMPS03 Référence : 0660-3 CMPS03 Magnetic Compass. Voltage : 5v only required Current : 20mA Typ. Resolution : 0.1 Degree Accuracy : 3-4 degrees approx. after calibration Output

More information

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module! Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8

More information

TAP Interface Specifications

TAP Interface Specifications TAP Interface Specifications This Document is for those who want to develop their own paging control software or add an interface for the WaveWare v9 Series Paging Encoder to their existing software applications.

More information

OPERATION MANUAL VALVE CHECKER G040-123

OPERATION MANUAL VALVE CHECKER G040-123 OPERATION MANUAL VALVE CHECKER AUSTRALIA PTY. LTD. L:\DWG_NO\DOCUMENT\MANUALS\Word File\A OPERATION MANUAL CN 20.4.99 VALVE CHECKER 1 of 20 CONTENTS Chapter Title Page 1. Description 3 2. Specification

More information

INSTRUCTION MANUAL. SIGNAL AMPLIFIER 4-20 ma

INSTRUCTION MANUAL. SIGNAL AMPLIFIER 4-20 ma INSTRUCTION MANUAL SIGNAL AMPLIFIER 4-20 ma 0305 260 IMPORTANT USER INFORMATION IMPORTANT USER INFORMATION Reading this entire manual is recommended for full understanding of the use of this product Should

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2. SIMATIC ET 200S distributed I/O SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Manual 04/2007 A5E01077339-01 Safety Guidelines

More information

RDF1. RF Receiver Decoder. Features. Applications. Description. Ordering Information. Part Number Description Packages available

RDF1. RF Receiver Decoder. Features. Applications. Description. Ordering Information. Part Number Description Packages available RDF1 RF Receiver Decoder Features Complete FM Receiver and Decoder. Small Form Factor Range up to 200 Metres* Easy Learn Transmitter Feature. Learns 40 transmitter Switches 4 Digital and 1 Serial Data

More information

1.Eastron SDM220Modbus Smart Meter Modbus Protocol Implementation V1.0

1.Eastron SDM220Modbus Smart Meter Modbus Protocol Implementation V1.0 1.Eastron SDM220Modbus Smart Meter Modbus Protocol Implementation V1.0 1.1 Modbus Protocol Overview This section provides basic information for interfacing the Eastron Smart meter to a Modbus Protocol

More information

IO Expansion Module User & Installation Manual

IO Expansion Module User & Installation Manual IO Expansion Module User & Installation Manual For FreeWave products: IOE-X-4422P IOE-X-4422PC December 10, 2009 1 User Manual Table of Contents Regulatory... 3 UL: Underwriters Laboratories... 3 General

More information

Solar Controller / Battery Charger User s Manual

Solar Controller / Battery Charger User s Manual Solar Controller / Battery Charger User s Manual 1 Congratulations! You have made an excellent choice by purchasing this high quality KORR PWM solar controller which has been manufactured to the highest

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

SX460. Generator Automatic Voltage Regulator Operation Manual

SX460. Generator Automatic Voltage Regulator Operation Manual SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.

More information

ROC Protocol Specifications Manual

ROC Protocol Specifications Manual Part Number D301053X012 June 2015 ROC Protocol Specifications Manual Remote Automation Solutions ROC Protocol Specifications Manual Revision Tracking Sheet June 2015 This manual may be revised periodically

More information

Symbols in subject lines. An in-depth look at symbols

Symbols in subject lines. An in-depth look at symbols An in-depth look at symbols What is the advantage of using symbols in subject lines? The age of personal emails has changed significantly due to the social media boom, and instead, people are receving

More information

PAC1 Door Access Controller

PAC1 Door Access Controller PAC1 Door Access Controller Series 2 IMPORTANT DIFFERENCES FROM SERIES 1 1. A PACDL data logger revision 4.0 or higher attached to the DLOG terminal is able to program all features (i.e. times, relay type,

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

Instruction Manual. T3111 T3111L T3111P T3111Ex

Instruction Manual. T3111 T3111L T3111P T3111Ex www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

Index...1. Introduction...3. Installation- Keyboard Wedge...3 RS-232...3 USB...3. Default Setting for each barcode shown as below:...

Index...1. Introduction...3. Installation- Keyboard Wedge...3 RS-232...3 USB...3. Default Setting for each barcode shown as below:... Index Index...1 Introduction...3 Installation- Keyboard Wedge...3 RS-232...3 USB...3 Default Setting for each barcode shown as below:...4 Programming the MS320...5 Interface Selection...7 Keyboard wedge...8

More information

Digital and Analog I/O

Digital and Analog I/O 70072-0127-07 TECHNICAL NOTE 02/2007 Digital and Analog I/O This document discusses the application and configuration of digital and analog inputs/outputs (I/O). Details are for both onboard I/O and external

More information

S4000TH HART. HART Communication Manual

S4000TH HART. HART Communication Manual HART Communication Manual The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by General

More information