PVC ENCLOSURES, LARGE JUNCTION BOXES & TROUGHS

Size: px
Start display at page:

Download "PVC ENCLOSURES, LARGE JUNCTION BOXES & TROUGHS"

Transcription

1 APPLICATIONS Industrial MRO and OEM Junction boxes Terminal blocks Control housings Instrumentation panels Electrical cabinetry A complete line of Electrical Non-Metallic Enclosures effective at lowering installation and life cycle costs. 56 FEATURES Royal Building Products Electrical Solutions PVC Enclosures are built for easy installation and an extended service life. They have longer lasting performance than metal enclosures, and are less costly in the long run. CONSTRUCTION Royal s PVC Enclosures are much lighter than metal enclosures, approximately less than half their weight. Smooth corners and edges make them easy to handle and install at a jobsite. The box is made from solid, one-piece PVC II construction with reinforced welded joints for a durable installation. The opening is sealed with a PUR-foamed seal for maximum protection. Screw style or hinged covers are available. PERFORMANCE PVC Enclosures perform well with no deterioration. The enclosure is sunlight, dirt and moisture-resistant, which prevents weathering and keeps wiring clean and operational. Royal Building Products PVC Enclosures provide a maintenance-free, professional-looking installation every time. CORROSION PROOF Resistant to most chemicals, PVC is typically not affected by corrosive soils or salts. NON CONDUCTIVE The non-magnetic and non-galvanic properties of Royal Building Products PVC Enclosures provides superior insulation and no power loss or conductor heating. FIRE RESISTANT The PVC II material used for Royal Building Products Enclosures meets the UL 94V-0 Flammability Standard - limiting flaming combustion to no greater than 10 seconds with no flaming particle discharges. IMPACT RESISTANT Royal Building Products enclosures are made from tough, durable, high tensile strength PVC. CUSTOMIZATION Factory assembled with the following custom options: Custom sizes Access windows Hinged windows Panel mounts Single or multiple hole openings Push button holes Vents Latches Locking systems Optional mounting flanges

2 SPECIFICATIONS Royal Building Products Electrical Solutions complete line of Electrical Non-Metallic PVC Enclosures is manufactured to meet UL 50 Standards as certified by ETL. NEMA 4X rated enclosures are for indoor or outdoor use, primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water and hose directed water per NEMA Standard DESIGN ADVANTAGES OF ROYAL PVC ENCLOSURES Pur Foam memory retaining gasket provides a watertight and dust-tight environmental seal CODES AND STANDARD COMPLIANCE Per UL 50 as tested by ETL, Royal Building Products PVC Electrical Enclosures meet NEMA Type 1, 2, 3, 3S, 3X, 4, 4X ratings. Made from grey engineered PVC II material, with fabricated bases and covers. PVC II material meets Outdoor Stability standards as measured by UL 746C f1, providing UV and water immersion testing. PVC II material is stable at 194 F as rated on PVC conduit products. The door has a PUR-foamed seal. The PVC is UL94V-0 rated, with the enclosures built to withstand NEMA 4X performance as tested and listed by ETL. PVC material allows the use of standard solvent cements for ease of fitting attachment. PVC Type II material with uni-body construction and penetration welding provides a strong, durable enclosure. Corrosion-resistant enclosures satisfy the requirements of Type 4X, and are suitable for food processing plants, dairies, refineries, water, waste and chemical processing, and any other industries where corrosion is prominent. Stainless steel fasteners provide extended corrosion resistance. 57 Made in USA. High Impact Resistant Body Triple-Latching door lock converts to keyed lock for a secure installation

3 58 ELECTRICAL TROUGH BOX (SCREW COVER) 4 x 4 x 12 ETR x 4 x 18 ETR x 4 x 24 ETR x 4 x 36 ETR x 4 x 48 ETR x 4 x 60 ETR x 6 x 12 ETR x 6 x 18 ETR x 6 x 24 ETR x 6 x 36 ETR x 6 x 48 ETR x 6 x 60 ETR x 6 x 72 ETR x 8 x 12 ETR x 8 x 18 ETR x 8 x 24 ETR x 8 x 32 ETR x 8 x 36 ETR x 8 x 48 ETR x 8 x 60 ETR x 12 x 24 ETR x 12 x 36 ETR x 12 x 48 ETR x 12 x 60 ETR x 18 x 72 ETR Mounting Feet (4) EJBMF4 1 Fasteners on lids spaced approximately every 6

4 4 x 4 x 12 ELC x 4 x 18 ELC x 4 x 24 ELC x 4 x 36 ELC x 4 x 48 ELC x 4 x 60 ELC x 6 x 12 ELC x 6 x 18 ELC x 6 x 24 ELC x 6 x 36 ELC x 6 x 48 ELC x 6 x 60 ELC x 8 x 12 ELC x 8 x 18 ELC x 8 x 24 ELC x 8 x 36 ELC x 8 x 48 ELC x 8 x 60 ELC x 12 x 24 ELC x 12 x 36 ELC x 12 x 48 ELC x 12 x 60 ELC Mounting Feet (4) EJBMF4 1 ELECTRICAL TROUGH BOX (LATCH HINGED COVER) 59

5 60 LARGE FABRICATED JUNCTION BOX (SCREW COVER) 12 x 8 x 4 E x 8 x 6 E x 8 x 8 E x 10 x 4 E x 10 x 6 E x 10 x 8 E x 12 x 4 E x 12 x 6 E x 12 x 8 E x 12 x 12 E x 12 x 4 E x 12 x 6 E x 12 x 8 E x 14 x 4 E x 14 x 6 E x 14 x 8 E x 14 x 10 E x 14 x 14 E x 16 x 10 E x 16 x 12 E x 16 x 16 E x 12 x 4 E x 12 x 6 E x 12 x 8 E x 16 x 4 E x 16 x 6 E x 16 x 8 E x 18 x 4 E x 18 x 6 E x 18 x 8 E x 18 x 10 E x 18 x 12 E x 18 x 18 E x 18 x 8 E x 20 x 8 E x 6 x 6 E x 18 x 6 E x 18 x 8 E Fasteners on lids spaced approximately every 6

6 24 x 18 x 12 E x 20 x 6 E x 20 x 8 E x 24 x 4 E x 24 x 6 E x 24 x 8 E x 24 x 10 E x 24 x 12 E x 24 x 24 E x 24 x 8 E x 30 x 10 E x 30 x 12 E x 30 x 20 E x 30 x 30 E x 18 x 12 E x 24 x 8 E x 24 x 24 E x 36 x 6 E x 36 x 12 E x 36 x 18 E x 36 x 20 E x 36 x 36 E x 40 x 12 E x 40 x 20 E x 40 x 40 E x 36 x 16 E x 48 x 24 E x 48 x 36 E x 48 x 48 E Mounting Feet (4) EJBMF4 1 LARGE FABRICATED JUNCTION BOX (SCREW COVER) 61 Fasteners on lids spaced approximately every 6

7 62 ELECTRICAL ENCLOSURES (HINGED COVER) 14 x 12 x 6 EBH x 18 x 8 EBH x 12 x 6 EBH x 12 x 8 EBH x 16 x 6 EBH x 16 x 8 EBH x 16 x 10 EBH x 16 x 12 EBH x 20 x 6 EBH x 20 x 8 EBH x 20 x 10 EBH x 24 x 6 EBH x 24 x 8 EBH x 12 x 6 EBH x 12 x 8 EBH x 12 x 10 EBH x 16 x 6 EBH x 16 x 8 EBH x 20 x 8 EBH x 20 x 10 EBH x 20 x 12 EBH x 20 x 16 EBH x 24 x 6 EBH x 24 x 8 EBH x 24 x 10 EBH x 24 x 12 EBH x 24 x 16 EBH x 30 x 8 EBH x 16 x 6 EBH x 20 x 6 EBH

8 30 x 20 x 8 EBH x 20 x 10 EBH x 24 x 6 EBH x 24 x 8 EBH x 24 x 10 EBH x 24 x 12 EBH x 24 x 16 EBH x 24 x 20 EBH x 24 x 24 EBH x 30 x 8 EBH x 30 x 12 EBH x 36 x 8 EBH x 24 x 6 EBH x 24 x 8 EBH x 24 x 10 EBH x 24 x 12 EBH x 30 x 6 EBH x 30 x 8 EBH x 30 x 10 EBH x 30 x 12 EBH x 30 x 16 EBH x 30 x 20 EBH x 36 x 8 EBH x 36 x 12 EBH x 24 x 8 EBH x 30 x 8 EBH x 30 x 10 EBH x 30 x 12 EBH x 36 x 8 EBH Mounting Feet (4) EJBMF4 1 ELECTRICAL ENCLOSURES (HINGED COVER) 63

JIC CONTINUOUS HINGE BOXES

JIC CONTINUOUS HINGE BOXES JIC CONTINUOUS HINGE BOXES Austin JIC Continuous Hinge (JH) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing.

More information

Scepter PVC Molded Junction Boxes

Scepter PVC Molded Junction Boxes Scepter PVC Molded Junction Boxes TM ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" Fully Certified: NEMA, UL & CSA We build tough products for tough environments Standing Still is Not an Option.

More information

Scepter PVC Molded Junction Boxes

Scepter PVC Molded Junction Boxes Scepter PVC Molded Junction Boxes ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" We build tough products for tough environments Standing Still is Not an Option. We re proud to introduce the NEW

More information

Type 1, 3, & 3R Enclosures

Type 1, 3, & 3R Enclosures Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................

More information

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

Application Guide Selection of Type Enclosures

Application Guide Selection of Type Enclosures Application Guide Selection of Type Enclosures. ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 1 Mission Statement The purpose of this document is to educate the reader with regard

More information

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures Meter Boxes SMB s To house a single phase kilowatt hour meter Standard kwh meter mounting Square or triangular securing screw Stand off for circuit breaker Optional circuit breaker reset rod DMB s To house

More information

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13 CONTROL PANEL INSTALLATION INSTRUCTIONS Single Phase Simplex Page 2-7 3-Phase Simplex Page 8-13 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions

More information

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to

More information

Temperature Controlled Enclosures

Temperature Controlled Enclosures 7 Indoors or Outdoors - We ve Got You Covered! Temperature Controlled Enclosures Protect your electronics and control their environment! FC Series - NEMA 3R outdoor enclosures with UL Listed fans, filters,

More information

New Cable Tie Type Classifications

New Cable Tie Type Classifications 1 New Cable Tie Type Classifications UL 62275 United States CSA C22.2 No. 62275 Canada NMX-J-623-ANCE Mexico Technically Equivalent to IEC 62275 All cable ties are not created equal!!! With an increasing

More information

SECTION 02630 STORM DRAINAGE SYSTEM

SECTION 02630 STORM DRAINAGE SYSTEM SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE

More information

BEDFORD DORMOBILE PARTS LIST JUNE 2016

BEDFORD DORMOBILE PARTS LIST JUNE 2016 BEDFORD DORMOBILE PARTS LIST JUNE 2016 FOR UK AND EU REGION REPRODUCTION PARTS FOR YOUR ORIGINAL DORMOBILE BEDFORD CA AND CF CONVERSIONS DORMOBILE LIFTING ROOF PARTS BEDFORD CA & CF Roof vent cover (colour

More information

Industry. Rail Leading Innovation in a Dynamic Industry. Sika Services AG

Industry. Rail Leading Innovation in a Dynamic Industry. Sika Services AG Rail Leading Innovation in a Dynamic Industry 1 Content 4 3 1 Direct Glazing_3 Interior Bonding_7 Exterior Component Bonding and Sealing_5 Interior Sealing and Fire Resistance Application_9 2 Floor Bonding_11

More information

V-ENC Enclosure Installation Guide

V-ENC Enclosure Installation Guide V-ENC Enclosure Installation Guide Veri-Series Outdoor Enclosure (Models VENC, VTENC, VNENC) March 23, 2005 Page 1 Introduction The Bioscrypt Veri-Series fingerprint readers are manufactured for indoor

More information

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute Cable Tray Wiring Systems Have Many Cost Advantages Cost is usually a major consideration in the selection of a wiring system.

More information

Series 18 Pass Thru Air Lock Cleanroom Entry System

Series 18 Pass Thru Air Lock Cleanroom Entry System OPERATION & MAINTENANCE INSTRUCTIONS FOR Series 18 Pass Thru Air Lock Cleanroom Entry System SOLUTIONS BUILT TO YOUR SPECIFICATIONS 8605 Wyoming Ave. N. Minneapolis MN 55445 fax: 763.425.2004 e-mail: sales@cleanairproducts.com

More information

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns for harsh & hazardous (classfied) locations Construction Demolition Maintenance Turnarounds Shutdowns D-13 temporary / mobile power Temporary power products are used on industrial and construction sites

More information

PAINT BOOTH LIGHTING

PAINT BOOTH LIGHTING PAINT BOOTH LIGHTING PAINT BOOTH LIGHTING Lighting is comprised of many components that need to be considered when selecting the appropriate fixtures and lamps to accomplish a specific task. Selecting

More information

IP Rating Chart. 910 East Orangefair Lane Anaheim, CA 92801 USA. www.anaheimautomation.com 714-992-6990 714-992-0471, Fax

IP Rating Chart. 910 East Orangefair Lane Anaheim, CA 92801 USA. www.anaheimautomation.com 714-992-6990 714-992-0471, Fax IP, NEMA and UL Rating Codes The International Protection Rating, sometimes referred to as an Ingress Protection rating, is a set of codes used to define specific levels of protection. These codes consist

More information

SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS

SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications

More information

Screen Enclosure Protect your Screen against: rain, temperature, vandalism damage and theft

Screen Enclosure Protect your Screen against: rain, temperature, vandalism damage and theft Screen Enclosure Protect your Screen against: rain, temperature, vandalism damage and theft When should I use a LCD enclosure? Designed to tolerate outdoor wet and wash down environments an LCD enclosure

More information

AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY. (The following code explanations are to be used with a copy of the 2011 NEC.

AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY. (The following code explanations are to be used with a copy of the 2011 NEC. AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY (The following code explanations are to be used with a copy of the 2011 NEC.) To obtain a copy of the NEC contact: National Fire Protection Association

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: sales@durasystems.com. The Passive Fire Protection Specialists

Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: sales@durasystems.com. The Passive Fire Protection Specialists Enclosures Sturdy single and double wall fire protection construction Impact resistant Fast & easy installation Pre-manufactured and modular Available in galvanized, stainless steel & other specialty metals

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Learning Module 13: Panelboards and Switchboards. 101 Basic Series Learning Module 13: Panelboards and Switchboards 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Definitions 4 Similarities Between Panelboards and

More information

FAIRFIELD INDUSTRIES INC.

FAIRFIELD INDUSTRIES INC. FAIRFIELD INDUSTRIES INC. v NEW PRICE SCHEDULE 4/1/201 SUPERSEDES 4/1/11 SPILL CONTAINMENT And STREET ACCESS MANHOLES for UNDERGROUND And ABOVEGROUND TANKS SPILL CONTAINMENT MANHOLES MONITOR WELL SERIES

More information

FAST Installation Manual

FAST Installation Manual FAST Installation Manual FOR USE WITH (NSF Std 40 & 245) MicroFAST 0.5, 0.625, 0.75, 0.9, 1.5 (non NSF certified) MicroFAST 3.0, 4.5, 9.0 NitriFAST 0.5, 0.625, 0.75, 0.9, 1.5, 3.0, 4.5, 9.0 HighStrengthFAST

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS

ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS ~GSM SHELTER CONTAINERS ARE PROCUDED ACCORDING TO THE DEMANDED SIZE.~ (W x L x H) Page1 GENERAL FEAUTURES Environmental Conditions : Maximum outdoor temperature

More information

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:

More information

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL Please read these instructions carefully and completely before attempting to install Hale Pet Doors; they will guide you through the steps

More information

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case

More information

IR WINDOW CERTIFICATION GUIDEBOOK. Copyright CorDEX Instruments Ltd. www.irwindows.com training@cord ex.com. ID 4016 Rev A

IR WINDOW CERTIFICATION GUIDEBOOK. Copyright CorDEX Instruments Ltd. www.irwindows.com training@cord ex.com. ID 4016 Rev A IR WINDOW CERTIFICATION GUIDEBOOK Copyright CorDEX Instruments Ltd. www.irwindows.com training@cord ex.com ID 4016 Rev A Content 1. General... Page 3 2. Introduction... Page 4 3. UL Underwriters Laboratories...

More information

Myers Hubs. The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure

Myers Hubs. The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure Myers Hubs The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure Myers Hubs The Original! Often imitated, never duplicated! Available in a wide range of sizes, materials

More information

Industrial Process Plants. Residential & Commercial Buildings. Roads & Tunnels. Airports & Seaports

Industrial Process Plants. Residential & Commercial Buildings. Roads & Tunnels. Airports & Seaports APPLICATION TYPE TEST Industrial Process Plants ANT-V: Reliable, safety switchgear Hundreds of ANT s Switchboards have been supplied to industrial factories. ANT-V siwtchboards are designed, fabricated

More information

Bafl-Sorb Sound Absorbing Ceiling Baffles

Bafl-Sorb Sound Absorbing Ceiling Baffles Bafl-Sorb Sound Absorbing Ceiling Baffles INC offers a complete line of Sound Absorbing Ceiling Baffles to compliment any environment. Our ceiling baffles are among the most cost-effective method of adding

More information

Low Voltage Transformers Sealed, General Purpose, Dry Type

Low Voltage Transformers Sealed, General Purpose, Dry Type Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................

More information

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-

More information

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM SPECIFICATION NO. SMAA-2P-8xE UPGRADE SMOOTH SURFACE / CAP SHEET / SINGLE PLY 2 PLY POLYESTER REINFORCED ACRYLIC

More information

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical

More information

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING 60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed

More information

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information

Thomas and Betts Corporation Product Guide Specification

Thomas and Betts Corporation Product Guide Specification Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat, and PageFormat, as described

More information

Garden Window. Montecito Series Vinyl Garden Window Architectural Manual

Garden Window. Montecito Series Vinyl Garden Window Architectural Manual Montecito Series Vinyl The offers the outstanding insulating properties, low maintenance, and contemporary aesthetic appeal only vinyl can provide. Available in White and Tan homogenous window frames,

More information

Carlon Bore-Gard and Boreable Multi-Gard Raceway

Carlon Bore-Gard and Boreable Multi-Gard Raceway Carlon Bore-Gard and Boreable Multi-Gard Raceway Bore-Gard Schedule 40 Bore-Gard Schedule 80 Boreable Multi-Gard Type 40 www.carlonsales.com 231 Bore-Gard Trenchless Raceway Carlon Bore-Gard Trenchless

More information

Basic Fire Door Requirements

Basic Fire Door Requirements TECHNICAL DATA SERIES S D I 118-01 Basic Fire Door Requirements 2001 Steel Door Institute STEEL DOOR INSTITUTE 30200 DETROIT ROAD - CLEVELAND, OHIO 44145 Technical Data Series SDI 118-2001 Basic Fire Door

More information

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

TABLE OF CONTENTS SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7 2 TABLE OF CONTENTS SECTION 1: What is a Standing Seam Metal Roof PAGE 3 SECTION 2: Common Types of Standing Seam Metal Roofs..PAGE 5 SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE

More information

LHD LINEAR HEAT D ETECTIONN

LHD LINEAR HEAT D ETECTIONN Tri-Metallic Core: Steel provides tensile strength Copper increase conductivity Tin for corrosion resistance LHD LINEAR HEAT D ETECTIONN TECHNICAL DATA Temperature Rating: 155 F (68 C) (typical temperature)

More information

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS WARNING Improper installation, adjustment, alteration, service, or maintenance of this product can cause

More information

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work. Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.

More information

Electrical Safety Products

Electrical Safety Products Electrical Safety Products Trelleborg Electrical Safety Products A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg

More information

TRITON CONTAINER INTERNATIONAL. Reefer Technical Bulletins. Version 4.0

TRITON CONTAINER INTERNATIONAL. Reefer Technical Bulletins. Version 4.0 TRITON CONTAINER INTERNATIONAL Version 4.0 February 2013 Table Of Contents (Hold Ctrl button and click on any item below to go directly to that section of the manual.) 1 INTRODUCTION... 3 2 REFRIGERATED

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Heating Cable. Construction

Heating Cable. Construction Mineral Insulated High Temperature A C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to F (593 C) Maximum Exposure Temperature 4 F (76 C) (Power Off) Corrosion Resistant

More information

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200

More information

MODEL HSR-007 Direct Drive Rolling Steel

MODEL HSR-007 Direct Drive Rolling Steel MODEL HSR-007 Direct Drive Rolling Steel 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 Tel: 866-792-9968 or 705-792-9968 Fax: 705-735-9564 www.tnrdoors.com email: info@tnrdoors.com Model HSR-007

More information

8' W x 8' H or 10' H Peak Style Shelter Assembly Instructions

8' W x 8' H or 10' H Peak Style Shelter Assembly Instructions ' W x ' H or ' H Peak Style Shelter Assembly Instructions Description ' x ' x ' Peak Style Shelter - Gray ' x ' x ' Peak Style Shelter - Gray Recommended Tools Please read instructions COMPLETELY before

More information

WHY CABLE TRAY? BECAUSE A CABLE TRAY WIRING SYSTEM PROVIDES SAFE AND DEPENDABLE WAYS TO SAVE NOW AND LATER

WHY CABLE TRAY? BECAUSE A CABLE TRAY WIRING SYSTEM PROVIDES SAFE AND DEPENDABLE WAYS TO SAVE NOW AND LATER Large numbers of electrical engineers have limited detail knowledge concerning wiring systems. There is the tendency by engineers to avoid becoming involved in the details of wiring systems, leaving the

More information

Life Insurance for Switches & Circuit Breakers

Life Insurance for Switches & Circuit Breakers Life Insurance for Switches & Circuit Breakers Surviving Harsh Environments Author: John Arnold Director Sales & Marketing APM HEXSEAL Unsealed electromechanical switches and circuit breakers offer limited

More information

HINGES FOR OUTWARD OPENING APPLICATIONS. Friction Hinges. Parts Brochure

HINGES FOR OUTWARD OPENING APPLICATIONS. Friction Hinges. Parts Brochure HINGES FOR OUTWARD OPENING APPLICATIONS Friction Hinges Parts Brochure ii 12-2002 Friction Hinges Index Product Liability Guidelines 4 General Design Description 5 Defender, Standard Purpose Friction Hinges

More information

AlarmLine Addressable Linear Heat Detector

AlarmLine Addressable Linear Heat Detector Line Addressable Linear Heat Detector P/N 7-0001-00 Effective: March 2008 K-7-02 FEATURES UL Listed FM Approved CSFM MEA (pending) Low-cost interface between Line sensor cable and control panel accepting

More information

Company DUOL. Dušan Olaj CEO

Company DUOL. Dušan Olaj CEO Company DUOL Company DUOL has been active on the market since 1992 and throughout this period Duol has successfully attained the position of one of the most significant suppliers of fabric structures.

More information

ROOF DRAINS TABLE OF CONTENTS

ROOF DRAINS TABLE OF CONTENTS Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF

More information

K17.12 Door closers K17. Doors 01.09.2013

K17.12 Door closers K17. Doors 01.09.2013 K17 Doors K17.12 01.09.2013 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com Contents 1. OPTIC door closer TS40(V) with scissor

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

Confort 160. Sliding Systems. Sapa Building System

Confort 160. Sliding Systems. Sapa Building System Confort 160 Sliding Systems Sapa Building System Confort 160 is a high performance thermally insulated sliding window system, with a user-friendly slide action. The system, which has an attractive aesthetic

More information

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),

More information

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant GAI-TRONICS A Hubbell Company PAGE/PARTY Solutions GAI-Tronics Page/Party communication systems provide paging and party-line capabilities... two important plant communication functions in one durable,

More information

MIDMARK DENTAL CABINETRY vs LOCAL CABINET MAKERS

MIDMARK DENTAL CABINETRY vs LOCAL CABINET MAKERS MIDMARK DENTAL CABINETRY vs LOCAL CABINET MAKERS Because dental practices are specialized treatment facilities, they have needs that are profession and practice specific. Integra Dental Casework and Artizan

More information

Removable Insulation Blankets from A to Z

Removable Insulation Blankets from A to Z Removable Insulation Blankets from A to Z At first glance, making up a removable insulation blanket seems somewhat simple take some insulation, put some mesh on one side, a cover on the other, sew them

More information

Now available with full IP65 rating: Protection from dust and water jets NEW: K470 Plus covered containers

Now available with full IP65 rating: Protection from dust and water jets NEW: K470 Plus covered containers Now available with full IP65 rating: Protection from dust and water jets NEW: K470 Plus covered containers Universal container K 470 the original since 1950 Often copied but never equalled or bettered

More information

NEMA Enclosure Types

NEMA Enclosure Types The purpose of this document is to provide general information on the definitions of NEMA Enclosure Types to architects, engineers, installers, inspectors and other interested parties. [For more detailed

More information

TRUCK BOXES - UNDERBODY BOXES

TRUCK BOXES - UNDERBODY BOXES TRUCK BOXES - UNDERBODY BOXES BLACK, STAINLESS STEEL T-HANDLE LATCH 14-gauge steel box, 12-gauge steel door (12-gauge steel box, 12-gauge steel door on 66" toolboxes). Recessed/beveled door. Rain channel

More information

Roof Curbs, Extensions and Equipment Supports

Roof Curbs, Extensions and Equipment Supports Roof s, Extensions and Equipment Supports December 2012 Roof Page s, Header Extensions and Equipment Supports Table of Contents Model GPI Standard and Optional Construction Features... 3 Model Number Code....

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

plumbing products guide

plumbing products guide plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly

More information

SECTION 07530 SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

SECTION 07530 SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings. SECTION 07530 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section includes the flowing: 1. Removal of existing roofing membrane. Existing bur roof has one overlay and penetration mastic is asbestos containing.

More information

vinyl replacement windows LOOKING FOR VINYL REPLACEMENT WINDOWS? Standard Features easy, trouble-free operation. window material formulated and

vinyl replacement windows LOOKING FOR VINYL REPLACEMENT WINDOWS? Standard Features easy, trouble-free operation. window material formulated and vinyl replacement windows LOOKING FOR VINYL REPLACEMENT WINDOWS? We are confident that we carry a style and size to suit your application. You can be sure that your investment will add value to your home,

More information

Pressure Vessels (Air Compressors) and LPG Tanks

Pressure Vessels (Air Compressors) and LPG Tanks Pressure Vessels (Air Compressors) and LPG Tanks 1. Identification of Workplace Hazard Any container, tank or vessel that contains pressurized material is a potential hazard to employees due to the force

More information

Aluminium Standard. Technical Data. Included in delivery

Aluminium Standard. Technical Data. Included in delivery luminium Standard UL / cul Robust aluminium enclosure for mechanical engineering and automation technology Fixing options for s and mounting plates Usable in wide temperature area Technical ata aterial:

More information

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER

More information

ELECTRICAL CONNECTORS

ELECTRICAL CONNECTORS ELECTRICAL CONNECTORS 07-09 00-09 04-09 99-09 116 ELECTRICAL CONNECTORS LIGHT POWER MODULES WORKS WITH STANDARD & LED BULBS! WORKS WITH STANDARD & LED BULBS! CALL US TODAY FOR YOUR MODULITE VEHICLE APPLICATION

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

2006-2007 Safeguard Storm Doors Beauty, the security of advanced design, and the guarantee of a lifetime.*

2006-2007 Safeguard Storm Doors Beauty, the security of advanced design, and the guarantee of a lifetime.* 2006-2007 Safeguard Storm Doors Beauty, the security of advanced design, and the guarantee of a lifetime.* 6 Designs To choose! Like all classic designs, Elite embraces balance and proportion while using

More information

Wastewater Capital Projects Management Standard Construction Specification

Wastewater Capital Projects Management Standard Construction Specification CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,

More information

Finding and Fixing Leaks

Finding and Fixing Leaks Finding and Fixing Leaks Where did all that water go? Could we have splashed all that water out of the tub? These are all common thoughts that can run through your mind when you open up the hot tub cover

More information

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency

More information

SECTION 07400 STANDING SEAM METAL ROOF

SECTION 07400 STANDING SEAM METAL ROOF SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and

More information

Steel Spill Containment Pallets

Steel Spill Containment Pallets Steel Spill Containment Pallets O DENIOS steel pallets and sumps are the icons in the industry for compliant containment and long-term service. Heavy gauge steel provides the durability and security demanded

More information

Universal MATE-N-LOK Connectors

Universal MATE-N-LOK Connectors Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00

More information

The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.

The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc. 26 D+D MARCH 2015 Building Envelope Roland Serino, P.E., Dryvit Systems Inc. here has always been a need for a more efficient way to build in large cities like Chicago, New York, Los Angeles or other central

More information

Rooflight INSTALLATION INSTRUCTIONS

Rooflight INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary

More information

EH-20 20m antenna. By VE3RGW

EH-20 20m antenna. By VE3RGW EH-20 20m antenna By VE3RGW Equivalent circuit of EH-20 (prototype 2A) antenna system. Upper cylinder Lower cylinder Ground Counter pose Phasing coil Impedance transformer and tune circuit Tune coil Feed

More information