ECOMASTER CLIMA USER S MANUAL
|
|
- Barrie Gibson
- 8 years ago
- Views:
Transcription
1 ECOMASTER CLIMA USER S MANUAL Version Página 1 de 6
2 1. DESCRIPTION OF OPERATION Operation of the Automatic Semi-automatic Air Conditioning Unit In Air Conditioning Operation, it is possible to vary: The temperature set for operation Speed of the air in the Evaporators Flaps for internal/external air. Switch on de-humidification Block compressor inlet. (ECO) Any variation in the speed, position of the flaps, De-humidification or Compressor blocking places the air conditioning system in semi-automatic mode and it can be switched to fully automatic mode by pressing the AUTO button. Página 2 de 6
3 1.1.1 Changing the Set Temperature The Temperature can be set between 17ºC and 27ºC (63-82ºF) using the (8) and (7) keys. When the temperature level is set below 17ºC (63ºF), the system engages forced chill mode (LO) and activates its maximum cooling power. (The screen displays LO) When the temperature is set above 27ºC (82ºF), the system engages forced heat mode (HI) and activates its maximum heating power (the screen displays HI).By pressing key (8) the selected temperature for the propulsion air increases. Each keystroke increases this temperature. By pressing key (7) the selected temperature for the propulsion air decreases. Each keystroke decreases this temperature. The key (2) is used to vary the speed of the air propelled by the anti-vapour fans. There are two air speeds, indicated by the colour of led No. 7. The state of the fans varies according to the key pressed (2) stopped (led off), minimum speed (led shows green), maximum speed (led shows red). The key is optional and it is not present in all the items in the Ecomaster Basic D family. It is used in order to place the anti-vapour flaps so that air propulsion goes to the feet or to the windscreen. If led No. 8 is off, this means that the air is directed to the windscreen; if it is showing red it means that the air goes to the feet. In order to handle the flap selecting the inlet of the outside fresh air, key (3) must be pressed. If led No. 9 is showing green, the flap will be placed so that the inlet of external air is allowed. On the contrary, if led No. 9 is red, the air will be re-circulating from inside the vehicle. Página 3 de 6
4 The Ecomaster Basic D control will automatically close the air flaps leaving them in recirculation position (led No. 9 showing red) in case the temperature control for passengers requires the activation of air conditioning. Nevertheless, the driver can open the flaps again by hand and leave them in renewal position (led No. 9 showing green) by pressing key (3). The control turns off each time the electricity supply is interrupted, through the general switch disconnection, and the activation of any outlet is impossible. As soon as it is powered on, it will turn on in the same conditions when it was turned off, that is to say, it remembers the previous state of all of the outlets Varying the speed of the Evaporator Ventilators The speed of the evaporators can be varied from levels 1 to 3. When the speed is altered, the system goes into manual mode and the led located next to key (1) will be switched off. If the (1) key is pressed, the system automatically recovers the corresponding speed and the led will shine again to indicate manual operation. To alter the speed, press the (2) key. Pressing it once will display the current speed on the screen; if it is pressed again, the value of the speed will be increased in a closed loop (from 3 it will change to 1). Note: If the bus is not equipped with roof-mounted heaters and the interior temperature is less than 12ºC, speed 0 may be selected while the system is warming up. If speed 0 is selected manually as in the preceding example then, once the interior temperature increases to 12.5ºC, the system will automatically take on the corresponding speed and will set itself to Automatic. Página 4 de 6
5 Changing the flap position The position of the flaps can be changed from external air to internal air. When the position is changed, the system switches to manual mode. If the key (1) is pressed, the system automatically recovers the corresponding position. To alter the flaps, press key (3). Pressing it once will indicate the current position; pressing it again will change the position. If the Coaster Climax is operating in air-conditioning mode and the interior temperature is 2ºC higher than that selected (Set), the flaps will switch to Automatic mode and will close Activation of ECO. If the (4) key is pressed, the letters ECO will appear on screen and the compressor will be disconnected. The system switches into Semi-automatic mode. Pressing the (4) key will have no effect if the system is not working in Dehumidification mode. If the (1) or (4) key is pressed, the ECO option will be switched off Activation of De-humidification (Reheat). If the (6) key is pressed, De-humidification will be activated. This will remain in operation for 15 minutes or until the (6) or (1) key is pressed again. Reheat cannot be activated if there are no heaters installed on the roof unit. Selecting the de-humidification option cancels out the ECO option Check Temperatures The internal and external temperatures can be checked by pressing the (5) key. The interior temperature is displayed first, then the exterior temperature when the key is pressed again, and so on in a loop. Página 5 de 6
6 2. ERROR DETECTION AND WARNINGS When the system receives the signal from the battery disconnector (+30), it first checks the outputs to check what charges are applied and to make sure there is no short-circuit. It also checks the status of the probes. If any anomaly is detected, it will indicate the error(s) on the Display using the following codes: CODE ERROR SOND. INT Internal Probe shorted or open SOND. ICE Ice Probe shorted or open SOND.CHN Channelling Probe shorted or open SOND.EXT Driver s External Probe shorted or open BOMBA PR Main Pump Outlet Shorted BOMBA RC Recirculating pump outlet shorted COMP Compressor outlet shorted V.TECHO Roof valve outlet shorted V.SUELO Floor valve outlet shorted ESTRIBO1 Speed 1 heater outlet shorted ESTRIBO2 Speed 2 heater outlet shorted AIRE Recirculating flaps outlet shorted VENT DER Right adjustable evaporator ventilator outlet shorted VENT IZQ Left adjustable evaporator ventilator outlet shorted REG CON Corto Salida Ventiladores Condensador Regulables VENT1 Corto Salida Velocidad 1 Ventiladores Evaporador VENT2 Corto Salida Velocidad 2 Ventiladores Evaporador VENT3 Corto Salida Velocidad 3 Ventiladores Evaporador AIRE ANT Corto Salida Recirculación Antivaho CALEFAC1 Corto Salida Calefactor Bajo Piso Velocidad 1 CALEFAC2 Corto Salida Calefactor Bajo Piso Velocidad 2 POT Error en la Auto Configuración del Pot If any of the above errors appears, the Ecomaster Clima will start to operate in accordance with the default operating programme. It is possible that the vehicle s interior temperature may not be regulated correctly under these conditions so it is recommended that the system should be reviewed by technical service personnel. Página 6 de 6
Automatic air conditioning system (with the Lexus Display Audio system)
Automatic air conditioning system (with the Lexus Display Audio system) Air outlets and fan speed are automatically adjusted according to the temperature setting. To display the air conditioning operation
More information3-2. Using the air conditioning system and defogger Automatic air conditioning system
Automatic air conditioning system Airflow and outlets are automatically adjusted according to the temperature setting. Press to display the air conditioning operation screen. Air conditioning operation
More information3. AIR CONDITIONER CONTROLLER (UNIT)
9 3. AIR CONDITIONER CONTROLLER (UNIT) Functions of Full Automatic Air Conditioner ler 1 1. Temp SW 2. Auto SW 3. OFF SW 4. Amb SW 5. Mode SW 6. Blower SW 2 3 10 5 8 7 9 Temperature control: Air mix actuator
More informationAutomatic air conditioning system
Automatic air conditioning system Airflow and outlets are automatically adjusted according to the temperature setting. Control panel Windshield defogger Driver s side temperature control dial Air conditioning
More informationBasic Technology Series
Basic Technology Series Fundamentals of Car Air Conditioning 2007 Air Conditioning #003 The Rear Cooler Construction Fan Fan Filter Figure A : Trunk Figure B : Overhead Dual Air-Conditioner In This Issue
More informationAutomatic air conditioning system
Automatic air conditioning system Airflow and outlets are automatically adjusted according to the temperature setting. With navigation system Owners of models equipped with a navigation system should refer
More informationAutomatic air conditioning system
Automatic air conditioning system Air outlets and fan speed are automatically adjusted according to the temperature setting. With navigation system Owners of models equipped with a navigation system should
More information01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09
0000-00 01-3 6810-20 1. FFH SPECIFICATION 01-4 0000-00 2. SYSTEM LAYOUT AND COMPONENTS 0000-00 01-5 01-6 0000-00 3. FFH GENERAL INFORMATION The system is to increase the coolant temperature quickly by
More informationPROCEDURES FOR SELF DIAGNOSTICS
PROCEDURES FOR SELF DIAGNOSTICS Baum Tools Unlimited Inc. March 31, 1999 TAU 2.1 READING ACTUAL VALUES 1. Remove the operating console from the TAU 2. At the upper side of the operating consol there is
More informationWorkshop Manual REVISÃO 4 FORMATO Nº 159 14.09.2010
Workshop Manual REVISÃO 4 FORMATO Nº 159 14.09.2010 INDEX 1 HEADLIGHT SET OPENING AND LAMPS REPLACEMENT 4 2 FRONT AND CENTRE DOORS 6 2.1 VALVES 7 2.2 DRIER FILTER 10 2.3 ELECTRONIC RELAY 12 2.4 INSTRUCTION
More informationAir Conditioning System
Air Conditioning System 1 Chonan Technical Service Training Center Chonan Technical Service Training Center 2 Objectives To understand the components of air conditioning system. To understand the control
More informationAir conditioning, electrical testing
just a test. Air conditioning, electrical testing 01-253 Wire and component test using VAG1598 A test box Special tools and equipment VAG 1598 A test box and VAG 1598/11 adapter cable and VAG 1598/12 VAG1526
More informationSection 6. Introduction to Automatic A/C. Automatic Temperature Control
Automatic Control Introduction to Automatic A/C The heating, ventilation and air conditioning (HVAC) system in a house contains a wall-mounted thermostat to control outlet temperatures, distribution and
More informationSection 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU
Automatic Temperature Control Diagnosis and Repair Diagnosis of Automatic A/C Systems The most common automatic A/C system malfunctions tend to be the result of basic air conditioning problems. These problems
More informationUSER S GUIDE REVISÃO 4 FORMATO Nº
USER S UIDE REVISÃO 4 FORMATO Nº 58 30.07.200 INDEX DOORS 6. NORMAL WORKIN OF DOORS 6.2 EMERENCY 7.3 MAINTENANCE 8.4 DOOR S SENSITIVITY 8 2 DRIVER S CABIN 9 2. STARTIN UP THE VEHICLE 9 3 DASHBOARD 0 3.
More informationAerosphere Midibus. Air Conditioning System. Operation Manual. Aerosphere Midibus 05/2013 P.N. 10000038A
Air Conditioning System Operation Manual Aerosphere Midibus 05/2013 P.N. 10000038A To receive the best performance from the air conditioning system, we suggest carefully reading this manual before operating
More informationREMOTE CONTROL MANUAL
REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read
More informationTouareg Heating/air-conditioning system
Service. Self-Study Programme 301 Touareg Heating/air-conditioning system Design and function The automobile is accompanying people more and more in their recreational time. In addition to the pure transport
More informationE85 Heating / Air Conditioning System
Table of Contents E85 Heating / Air Conditioning System Subject Page E85 Heating / Air Conditioning System...3 IHKS...3 IHKS Components...3 IHKS Principle of Operation... 8 IHKA...11 IHKA Components...11
More informationV.A.G. Service. CLIMAtronic. CLIMAtronic USE AT YOUR OWN RISK. This document is an UNOFFICIAL translation of: V.A.G. Service
V.A.G. Service CLIMAtronic Construction and Function Self-Study Program 135 This document is an UNOFFICIAL translation of: V.A.G. Service CLIMAtronic Konstruction and Funktion Selbststudienprogramm Nr.
More informationHVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC
HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC Page. Basic Diagnostic Procedure.... General Description...3 3. Electrical Components Location...6 4. A/C Control Module I/O Signal...8 5. Self-diagnosis...0 6.
More informationSERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT
More informationUSER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
More informationSERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
More informationHEATER, AIR CONDITIONING AND VENTILATION
55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT
More informationTSB #: 74 Date: 9/7/2013 HOLDEN VE/WM HVAC & A/C DIAGNOSTIC HINTS
HOLDEN VE/WM HVAC & A/C DIAGNOSTIC HINTS TSB #: 74 Date: 9/7/2013 Initial Once Read: In this technical bulletin we have listed diagnostic advice relating to the Holden VE/WM HVAC & A/C system. This information
More informationVW Climatronic (by Hella) Self-Diagnostics
VW Climatronic (by Hella) Self-Diagnostics Original Author: Roger, Location: Greater Frankfurt am Main Posted on: 09-09-2004 Original Title: Eigendiagnose an der VW Climatronic von Hella Translation by:
More informationHeating/Ventilation. As regards the heating and ventilation system in the Fabia, two equipment versions are available:
Heating/Ventilation SP 32_111 As regards the heating and ventilation system in the Fabia, two equipment versions are available: a heater unit an automatic heater/air conditioning unit. A recirculated air
More informationits ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
More informationE46 IHKA... 4. Control Panel... 4. Fresh Air Micro Filter... 5. Temperature Regulation - Heating... 6. Temperature Regulation - Cooling...
Table of Contents E46 CLIMATE CONTROL Subject Page E46 IHKA................................................ 4 Control Panel........................................... 4 Fresh Air Micro Filter......................................
More informationAIR COOLED CHILLER CHILLED WATER PUMP CONTROL: The chilled water pump with the lowest runtime will automatically start when the outside air temperature rises above the system enable setpoint. When the
More informationSERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY
RV Products Division SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY Airxcel, Inc. RV Products Division P.O. Box 4020 Wichita, KS 67204 1976A376 (1-11) TABLE OF CONTENTS
More informationDirect Fresh Air Free Cooling of Data Centres
White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The
More informationC-Bus Application Messages & Behaviour Chapter 25 Air Conditioning
C-Bus Application Messages & Behaviour Chapter 25 Air Conditioning Document Number: CBUS-APP/25 Comments on this document should be addressed to: Engineering Manager Clipsal Integrated Systems PO Box 103
More informationE70 Climate Control Systems (IHKA, IHKA w/fka, Third Row HV)
Table of Contents (IHKA, IHKA w/fka, Third Row HV) Subject Page Introduction..................................................5 System Functions.............................................6 Temperature
More informationNewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS PARTS LIST Front Back FIG.5 FIG.6 1. Control panel 2. Carrying handle 3. Water tank 4. Casters
More informationSERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
More informationA/C-HEATER SYSTEM - AUTOMATIC
A/C-HEATER SYSTEM - AUTOMATIC 1995 Volvo 850 1995-96 Auto. A/C-Heater Systems Volvo 850 * PLEASE READ THIS FIRST * WARNING: To avoid injury from accidental air bag deployment, read and carefully follow
More informationOperation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.
English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation... 3 3.2 The user interface
More informationSERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY
SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY! WARNING - SHOCK HAZARD! TO PREVENT THE POSSIBILITY OF SEVERE PERSONAL INJURY, DEATH, OR EQUIPMENT DAMAGE DUE TO ELECTRICAL
More informationThe Phaeton Heating and Air Conditioning System
Service. Self-Study Programme 271 The Phaeton Heating and Air Conditioning System Design and Function An outstanding climate As a luxury performance saloon, the Phaeton is fitted with a four-zone cabin
More information1993 WIRING DIAGRAMS Volkswagen Wiring Diagrams. Volkswagen; EuroVan
Article Text ARTICLE BEGINNING 1993 WIRING DIAGRAMS Volkswagen Wiring Diagrams Volkswagen; EuroVan COMPONENT LOCATION MENU COMPONENT LOCATIONS TABLE ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
More informationOperation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3
EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3 English Table of Contents Table of Contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview:
More informationAir Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
More informationBuilding Energy Systems. - HVAC: Heating, Distribution -
* Some of the images used in these slides are taken from the internet for instructional purposes only Building Energy Systems - HVAC: Heating, Distribution - Bryan Eisenhower Associate Director Center
More informationSingle Zone LCD Thermostat Operating Instructions
Fan Cool Furnace *Heat Pump or Heat Strip On/Off F Single Zone LCD Thermostat Operating Instructions MODEL 3313192.XXX Cool/Furnace 3313193.XXX Cool/Furnace/Heat Pump 3313194.XXX Cool/Furnace/Heat Strip
More informationGlossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
More information06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)
Certificate Certified Passive House Component For cool, temperate climates, valid until 31 December 2013 Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Category: Manufacturer: Heat
More informationLesson 36 Selection Of Air Conditioning Systems
Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section
More informationUSER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
More informationAUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM
SECTION 7D AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM TABLE OF CONTENTS Description and Operation... 7D- General... 7D- FATC Control... 7D- FATC Input/Output Routing Diagram...
More informationFAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7
FAQs Conserve package Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7 FAQs Gateway Can I have someone install my system for me? If you are concerned
More informationUB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
More informationPORTABLE AIR CONDITIONER (LOCAL)
EN PORTABLE AIR CONDITIONER (LOCAL) OPERATING INSTRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance work. Observe all the safety instructions; failure
More informationUSER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
More informationWhat s the Difference? 2 Pipe vs 4 Pipe Fan Coil
Head Office Neptronic 400 Lebeau Blvd. Montreal, Quebec, Canada H4N R6 Tel.: (54) -4 Fax: (54) -6 Toll Free: -800-6-08 What s the Difference? Pipe vs 4 Pipe Coil There are many questions that arise when
More informationusing the Remote Touch unit and push knob to select. STEP 5 Select category and push knob to select. Scroll to specific customization setting.
Lexus Personalized Settings Your vehicle includes a variety of electronic features that can be programmed to your preferences. Programming of these features is performed once at no charge by your Lexus
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
More informationService Tips Fault Codes
/ / / Fault Codes Service Tips Fault Codes DISHWASHER TEST PROGRAM ERROR CODES (on 2 & 3-digit digital displays): 00 0 No faults 1 Aqua Sensor (Sensotronic) fault 2 Heating system fault (heater, Hi-Limit,
More informationChallenges for air conditioning and heating solutions in electrobuses
Dr.-Ing. Robert Basile, Director R&D Challenges for air conditioning and heating solutions in electrobuses The energy supply to electric buses remains a major challenge. Against a background of limited
More informationPerformance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling
for Simultaneous Heating and Cooling F. Sustainable Energy Centre, University of South Australia Mawson Lakes Boulevard, Mawson Lakes 5095 AUSTRALIA E-mail: Frank.@UniSA.edu.au Abstract The high efficiency
More informationSTERILIZERS, LABORATORY DRYING OVENS
TS9026 TS9053 TS9135 TS9430 TS 9000 SERIES: STERILIZERS, LABORATORY DRYING OVENS Series TS9000 consists of four different cabinets available in sizes from 26 litres to 430 litres. Interior housing and
More informationNational Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
More informationOperation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.
EHYHBH05AA EHYHBH08AA EHYHBX08AA English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation...
More informationHeat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools
Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL
More informationHybrid Air Conditioning Systems Overview
Southern Illinois University Carbondale OpenSIUC Presentations Department of Automotive Technology Spring 2011 Hybrid Air Conditioning Systems Overview Eugene Talley Southern Illinois University Carbondale,
More informationPorcia, 20 novembre 2012
1 2 PLZ RANGE 14-18-20 3 TECHNICAL NUMBERS 4 MAIN COMPONENTS CONTROL SAFETY HYDRONIC OUTLET WATER TEMPERATURE INLET WATER TEMPERATURE AIR OR WATER EXTERNAL TEMPERATURE FRESH AIR WITH PRESSURE DIFFERENTIAL
More informationSustainable Preservation Practices for Managing Storage Environments Webinar: April 3, 2013
The Fundamentals of HVAC: What Shapes the Storage Environment Sustainable Preservation Practices for Managing Storage Environments Webinar: April 3, 2013 Introduction Presenter Jeremy Linden, Preservation
More informationUse and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
More informationPresentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks
Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same
More informationHVAC SYSTEM (HEATER, VENTILATOR, AND A/C)
HVAC SYSTEM (HEATER, VENTILATOR, AND A/C) HEATER SYSTEM 1. Heater System A: GENERAL A semi-center type integrated air conditioning unit is used, where a high performance heater core and an evaporator core
More informationspecializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP
specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect
More informationTransport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units.
R Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL for SPLIT SYSTEM Bus Air Conditioning Units T--326 Rev -- OPERATOR S MANUAL BUS AIR CONDITIONING UNITS GEN IV & GEN V CONTENTS
More information1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target
4-2 ABNORMAL OPERATI 4-2-1 An is represented by 3 digit characters. The first 2 digit means the subsection, and the last 1 digit means the specifics. Ex.) Indoor unit Network communication Error Subsection
More informationSMM. Installation Operation Maintenance
SMM Configuration SMM Module for Scroll Units, H Generation Installation Operation Maintenance 1 0 L80 IM 022 GB SMM Configuration SMM Module for Scroll Units, H generation Foreword These installation,
More informationINSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR
INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR INTRODUCTION The Cirro MK 3 is a fully professional mist generator for producing sufficient airborne reflection particles to enable effect lighting to
More informationAll the best brands all under one roof
All the best brands all under one roof Year round comfort and energy efficiency The air conditioner you choose today is going to be with you for a long time, so it s important to choose wisely. The best
More informationHEATING, VENTILATION & AIR CONDITIONING
HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating
More informationHeat Recovery from Data Centres Conference Designing Energy Efficient Data Centres
What factors determine the energy efficiency of a data centre? Where is the energy used? Local Climate Data Hall Temperatures Chiller / DX Energy Condenser / Dry Cooler / Cooling Tower Energy Pump Energy
More informationTechnical data. Danfoss DHP-A
Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs
More informationPORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
More information2.1 The performance of bus air conditioning system is evaluated in the following operating conditions
1.0 Scope:- This test procedure is applicable for testing the Air Conditioning system performance at hot ambient and very hot ambient condition on intracity urban bus in a climatic hot chamber. This procedure
More informationTECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. Tankless Electric (RTE) Troubleshooting
Sequence of Operations 1 Power supply and field wiring block 2 Energy Cut Off (ECO) 3 Water flow plunger and cold inlet 4 Magnetic flow switch 5 Water temperature thermistor 6 Control panel and circuit
More informationAN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
More informationPANASONIC TROUBLE SHOOTING GUIDE
A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling
More informationYijun Gao, Wei Wu, Zongwei Han, Xianting Li *
Study on the performance of air conditioning system combining heat pipe and vapor compression based on ground source energy-bus for commercial buildings in north China Yijun Gao, Wei Wu, Zongwei Han, Xianting
More informationMAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing )
MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing ) The Concept Maximum Heat Load Temperature Testing is a powerful air-conditioning diagnostic and evaluation technique. It is also
More informationINSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE
More informationFailure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
More informationEnergy savings in commercial refrigeration. Low pressure control
Energy savings in commercial refrigeration equipment : Low pressure control August 2011/White paper by Christophe Borlein AFF and l IIF-IIR member Make the most of your energy Summary Executive summary
More informationHVAC Systems: Overview
HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct
More informationTouareg Component Locations No. 802 / 1
Touareg Component Locations No. 802 / 1 1 Fuses 1.1 Fuses 1.1.1 Overview of Fuses 1 - Fuses (SB) on fuse panel B on left instrument panel Location page 3 Fuse Arrangements, from November 2006 page 4 2
More informationNew Trends in the Field of Automobile Air Conditioning
New Trends in the Field of Automobile Air Conditioning E. Janotkova and M. Pavelek Department of Thermomechanics and Environmental Engineering Brno University of Technology, 61669 Brno, Czech Republic
More informationAmmonia Detection System Codes and Design Specifications
Ammonia Detection System Codes and Design Specifications December 28, 2015 Revision 5 920 N Trade Winds Pkwy Columbia, MO 65201 Ammonia detection system codes and design specifications Following is a discussion
More informationElectronically Controlled Clutchless or Variable Drive Compressors
Electronically Controlled Clutchless or Variable Drive Compressors On many new air conditioning systems, such as Lexus, Cadillac, Chrysler, and others, a new type of compressor has been fitted. There are
More informationELECTRIC POSITION for electric heat, then confirm with Fan Test below.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
More informationSECTION 2 3 OPERATION OF INSTRUMENTS AND CONTROLS. Lights, Wipers and Defogger
OPERATION OF INSTRUMENTS AND CONTROLS Lights, Wipers and Defogger SECTION 2 3 Headlights and turn signals................................... 92 Emergency flashers..........................................
More informationSensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved.
Sensi TM Wi-Fi Programmable Thermostat MANUAL OPERATION Version: March 2016 2016 Emerson Electric Co. All rights reserved. Contents MANUAL OPERATION GUIDE Buttons and Icons 3 Basic Functionality 4 Manual
More informationPERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA
specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA CONTROL & OPERATING INSTRUCTIONS The controls on your new
More informationHeater and Air Conditioner, Blend Air System, Troubleshooting 83.06
A/C Performance Diagnosis Problem Warm Airflow When the Air Conditioner is On, A/C Not Working, or Poor A/C Performance (dash outlet temperature is too high) Problem Warm Airflow When the Air Conditioner
More information