Porcia, 20 novembre 2012
|
|
- Dayna Summers
- 8 years ago
- Views:
Transcription
1 1
2 2 PLZ RANGE
3 3 TECHNICAL NUMBERS
4 4 MAIN COMPONENTS CONTROL SAFETY HYDRONIC OUTLET WATER TEMPERATURE INLET WATER TEMPERATURE AIR OR WATER EXTERNAL TEMPERATURE FRESH AIR WITH PRESSURE DIFFERENTIAL WATER SAFETY THERMOSTAT (96+0-6) PELLET SAFETY THERMOSTAT (88+0-6) VACUUM SWITCH MICROSWITCH FIREBOX DOOR (evaluation) MICROSWITCH PELLET LID (evaluation) VARIABLE CIRCULATOR (ON REQUEST CLASS A PWM DRIVED) AIR PURGE EXPANSION TANK (6l) SAFETY WATER PRESSURE VALVE(2,5 bar)
5 5 LAYOUT MANOMETER CONTROL PANEL SAFETY THERMOSTAT WATER/PELLET AESTHETIC FINISHING FRESH AIR INTAKE IGNITER FEEDING MOTOR
6 6 LAYOUT AIR PURGE BOILER (60L) FUNCTIONAL FIREBOX DOOR SERVICE WINDOW OPENING KNOBS
7 7 LAYOUT PELLET LID FUEL HOPPER FEEDING SYSTEM FRESH AIR INTAKE FIREBOX DOOR
8 8 LAYOUT WATER POCKET WATER OUTLET INSULATED DOOR CLEANING SPRING WATER INLET BURN POT ASH PAN CLEANING SYSTEM
9 9 LAYOUT EXHAUST OUTLET WAYS CLEANING AREAS WATER POCKET WATER EXCHANGER PIPES WATER JACKET
10 10 LAYOUT SPIDER CLEANING SYSTEM WITH SPRINGS EXPANSION CHAMBER/PLENUM EXHAUST OUTLET
11 11 ELECTRONIC
12 12 CONTROL BOARD ON LIGHTING STAND BY OFF
13 OPERATION BETWEEN MENU Left/Right arrows ->move between menus +/- buttons ->move between lower menus enter button -> confirm operation +/- buttons ->modify values cancel button -> go back to previous menu Power button perform ON/OFF or reset alarms
14 SETUP LOWER LEVELS [ 1 ] KEYBOARD LOCK : OFF / lo / hi [ 2 ] DISPLAY BRIGHTNESS : Min 1 / Max 5 [ 3 ] ROLLING MENU : OFF (Last value set) / 1 (temperature, range, clock) / 2 (temperature) / 3 (clock) / 4 (range) [ 4 ] BUZZER VOLUME = OFF / (Min) 1 / (Max) 5 [ 5 ] SOFTWARE VERSION [ 6 ] HOURS TO SERVICE [ 7 ] INSTALLER MENU [ 8 ] SERVICE MENU
15 15 HEATING SYSTEM CONFIGURATION [ 7 ] r r
16 16 CONFIGURATION 1 2 SET Outlet temperature (T01) Power (P)
17 17 CONFIGURATION 1
18 18 CONFIGURATION 2 3 SET Room Temperature (T05) Outlet Temperature (T01) Relighting Delta Room Temperature Antifreeze Temperature Power (P)
19 19 CONFIGURATION 2!
20 20 CONFIGURATION 3 SET Heat Storage Temperature (T05) Relighting Delta Heat storage Temperature Antifreeze Temperature Power (P) 3
21 21 CONFIGURATION 4 SET Heat Storage Temperature (T05) Relighting Delta Heat storage Temperature Antifreeze Temperature Power (P) 3
22 22 CIRCULATOR WORKS (configuration 1 and 2)
23 23 CIRCULATOR WORK (configuration 3 and 4)
24 24 WORK DEFINITION
25 25 POWER LEVEL SET [ 1 ] 1 min=1 MAX=5
26 26 TEMPERATURE SET [ 1 ] T05 T01 T02 DESCRIPTION CONFIGURATION Room T (T05) [1] Heat storage T (T05) [1] [1] Outlet T (T01) [1] [2] Antifreeze T [3] [2] [2] Relighting [4] [3] [3]
27 27 TEMPERATURE SETS T05 T01 T02 DESCRIPTION Room T (T05) [1] CONFIGURATION Heat storage T (T05) [1] [1] Outlet T (T01) [1] [2] Antifreeze T [3] [2] [2] Relighting [4] [3] [3] Room temperature (configuration 2 only): setting this value defines the desired room temperature, read directly by a probe fitted on the stove. Storage temperature (configurations 3 and 4 only): identifies the minimum desired temperature inside the storage tank. Water temperature (configurations 1 and 2 only): setting this value changes the desired hot water outlet temperature. Frost protection temperature (configurations 2, 3 and 4): defines the minimum temperature below which the stove switches on (outside of preset time bands). Restart delta (configurations 2, 3 and 4): this is the number of degrees centigrade below the switch-off temperature at which the stove switches on again automatically. For example, if the stove is set to switch off at 20 C and Restart delta is set to 4 C, the stove will switch on again when the temperature measured is less than or equal to 16 C.
28 28 FUNCTIONS AVAILABLE ECO MODE SAVING FUNCTION Enabling this function means that the stove switches off when reaching the desired room temperature. If this function is not enabled, the stove modulates operation so as to maintain the desired temperature while consuming the least amount of fuel possible. The "Eco Mode" function is only available in configuration 2. FROST PROTECTION FUNCTION In configurations 2, 3 and 4 a minimum temperature can be set below which the stove will switch on (outside of the set time bands).
29 29 TIMER MENU
30 30 TIME RANGE [ 3 ] [ 1 2 [ P 3 0] 1] P Ton Toff
31 31 SET UP PROGRAM [ 4 ] [ P d 1] 2] d 21 Programms TIME SLOTS P1 P3 P5 2 P1 P3 P5 3 P1 Off P4 4 P1 P3 P5 5 P1 P3 P5 6 P1 P2 P4 7 P6 Off Off
32 32 SERVICE MENU [ 8 ] r r KW
33 33 SERVICE MENU FACTORY DEFAULT VALUES DIGITAL INPUT ANALOG INPUT DIGITAL OUTPUT COUNTER ALARM MEMORIES
34 34 FUNZIONE LIMITI PAR00 durata massima Fuel Ignition (±1) PAR01 Timeout fase di FireCheck (±1) FEEDER-1 PAR03 durata OFF coclea HeatUp (±1) PAR04 durata lavoro coclea HeatUp (±1) PAR05 durata OFF coclea Fuel Ignition (±1) PAR06 durata lavoro coclea Fuel Ignition (±1) PAR07 durata OFF coclea FireCheck (±1) PAR08 durata lavoro coclea FireCheck (±1) PAR10 durata lavoro coclea potenza (±1) PAR18 durata lavoro coclea potenza (±1) FAN-1 PAR19 portata ventilatore fumi in StopFire (±1) PAR20 portata ventilatore fumi in TestFire (±1) PAR21 portata ventilatore fumi in HeatUp (±1) PAR22 portata ventilatore fumi in Fuel Ignition (±1) PAR23 portata ventilatore fumi in FireCheck (±1) PAR24 portata ventilatore fumi in potenza (±1) PAR28 portata ventilatore fumi in potenza (±1) WATER PAR50 deltat per uscita dal CoolFluid (±1 ) PAR52 temp MAX modulazione acqua (±1 ) PAR53 deltat per ingresso in CoolFluid (solo in CONF1/3/4) (±1 ) GASSES PAR54 temp fumi per uscita da FireCheck (±1 ) PAR55 MAX temp fumi per modulazione (±1 ) PAR56 temp fumi per uscita da StopFire (±1 ) PAR57 temp fumi MAX (±1 ) PAR59 MIN temp fumi durante lavoro (±1 ) CLEANING PAR60 tempo tra due cicli di pulizia (±1 ) PAR61 tempo ciclo pulizia (±1 ) PAR62 portata ventilatore fumi in pulizia (±1) WATER PUMP PAR67 T media mand/rit per passaggio da anti-condensa a lavoro pompa (±1 ) PAR68 T media mand/rit per start pompa (±1 ) PAR69 deltat mand/rit MAX per modulazione pompa (±1 ) TIMING PAR70 durata fase di HeatUp (±1 ) PAR71 durata calcolo gradiente (±1 ) PAR72 deltat calcolo gradiente (±1 ) OPERATING MODE PAR76 Configurazione di default (±1) PRESS/FLOW PAR82 press MIN in accensione (±1) PAR83 delay prima di verificare PAR (±1 ) HEAT ACC. PAR85 deltat mand/rit MIN per start pompa (±1 ) PAR86 deltat mand/puffer MAX per modulazione pompa (±1 ) MATERIAL TYPE PAR92 tipo pellet di default (±1) SERVICE HOURS PAR94 giorni per avviso di manutenzione (±1) ADVANCED WATER SERVICE MENU
35 35 WORKING LOGICS
36 36 WORKING LOGICS Fire Up 1. Test Fire: verify presence of embers. In that case exclude the igniter 2. Heat Up: Igniter, exhaust fan and feeding system switch on 3. Ignition: Waiting flame 4. Ignition Test: Check temperature in order to know if flame is present
37 37 WORKING LOGICS Burning 1. Power levels: Power Regulation Air: Room Fan speed (air version) 1 5, Auto, Hi 3. Regulation Gas: Safety exhaust temperature modulation 4. Regulation Fluid: Outlet temperature modulation 5. Burn Pot : Cleaning Cycle
38 38 WORKING LOGICS Fire down 1. Stop Fire: exhaust fan at full speed to clean burn pot and cool down the stove. 2. Cool fluid: stove is in stand-by status. Switch off condition (EcoMode) because target air/water is reached. On temperature demand stove will lighting automatically.
39 39 WORKING LOGICS OFF 1. OFF: burn pot is cold. Stove is waiting an external event (button, timer or thermostat)
40 40 WORKING LOGICS Pressure = AIR FLOW Fresh air intake P- P+ exhaust FAN RPM current AIR FLOW BEFORE: From RPM we got AIR FLOW NOW: From AIR FLOW we get RPM time
41 41 SERVICE MENU
42 42 SERVICE MENU
43 43 SERVICE MENU
44 44 SERVICE MENU
45 45 WARNINGS
46 46 ALARMS
47 47 THANK YOU FOR YOUR ATTENTION!
REMOTE CONTROL MANUAL
REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read
More informationDealer Sales & Service Guide
Analog Models w/thermostat or Timerstat Heat Siphon Not Starting 1 BREAKER TRIPPED - Check Breaker Box for correct size breaker Breakers: EX; Domestic model 2.25hp (20amp) 3.25hp (40amp) 5hp (50amp) check
More informationIQAN MDM Operation Manual
IQAN MDM Operation Manual Purpose The primary purpose of this document is to inform a user of the IQAN system on the ease of adjustments of the system. A person can create a much smoother machine control
More informationUSER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
More informationits ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
More informationOperation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.
EHYHBH05AA EHYHBH08AA EHYHBX08AA English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation...
More informationOperation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3
EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3 English Table of Contents Table of Contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview:
More informationOperation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.
English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation... 3 3.2 The user interface
More informationTHERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.
THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES
More informationSTERILIZERS, LABORATORY DRYING OVENS
TS9026 TS9053 TS9135 TS9430 TS 9000 SERIES: STERILIZERS, LABORATORY DRYING OVENS Series TS9000 consists of four different cabinets available in sizes from 26 litres to 430 litres. Interior housing and
More informationELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
More informationPELLEXIA COMFORT ENVIRONMENT COMPATIBLE
PELLEXIA COMFORT ENVIRONMENT COMPATIBLE To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50
More informationDrayton Digistat +2RF
Drayton Digistat +2RF T Programmable Room Thermostat Wireless 24 Hour Model: RF700/22090 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130
More informationSERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT
More information1 General information
1 General information 1.1 About this manual This manual describes the installation, function and operation of an integrated solar control system, which is suitable for split pressurized solar heating system.
More informationNOTE: Append this Operation IB to the Install IB to make one IB-booklet. Need a divider tab between the 2 sections. Blank page remove.
Product Name: CT101 Document Title: CT101 Operation Guide Document Type Code: IBOE Part Number: 1202-004-002 20apr12 Iris inclusion text added mtf 9apr12 bs edits mtf 14mar12 ch edits mtf 13mar12 initial
More informationALL IN ONE. Heat Pump Water Heater
ALL IN ONE Heat Pump Water Heater INSTALLATION AND OPERATION INSTRUCTIONS Please read this user s manual carefully before operate the unit. www.airtradecentre.com CONTENTS A. IMPORTANT REMARKS ------------------------------------------------------------------------------------------------
More informationCondensing Boiler Efficiency
Condensing Boiler Efficiency Date: July 17, 2012 PRES E NT ED BY DO N L E O NA RDI LE O N A RD I I NC. HV AC T RAI N I N G & C ON SU LT IN G Concepts 1 The current state of evolution in boiler design 2
More informationUser manual. 086U6297 Rev. 9 EN
User manual Atria Atria Duo Atria Duo Optimum Atria Optimum Comfort Diplomat Diplomat Duo Diplomat Duo Optimum Diplomat Duo Optimum G2 Diplomat Optimum Diplomat Optimum G2 086U6297 Rev. 9 EN Thermia Värme
More informationNexus FS Point of Use Installation Guide
Nexus FS Point of Use Installation Guide Nexus FS POU Install Guide:12152011:rev-12152011 Technical Specifications Dimensions: Height: 43.5 Width: 11.65 Depth: 15 Weight: 34.39 LBS Electrical Specs: Voltage:
More informationFossil fuel heating equipment
Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating
More informationUser Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
More informationSERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
More informationDomestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +
MAKING MODERN LIVING POSSIBLE User Guide DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro + www.heating.danfoss.com The English language
More informationCGC s Hybrid System Loop Control
verview The CGC Group Hybrid Heat Pump System does NT operate with the same fluid loop temperatures as a conventional reversing Water Source Heat Pump system. The CGC system differs from a WSHP system
More informationHot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE
Hot Water Boilers and Controls Why Condensing Boilers are Different Presented Oct. 14, 2008 Long Island Chapter, ASHRAE H.W. Boilers and Controls Major types of boilers Advantages and disadvantages Resistance
More informationAVR Pellet Control Board Installation/Service Instructions 250-00011
VR Pellet Control Board Compatibility valon ewport PS and ewport Bay PI (vanti PS & PI) valon storia PS and storia Bay PI Lopi Pioneer PS and Pioneer Bay PI (eritage PS & PI) Lopi Yankee PS and Yankee
More informationecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
More informationBoiler & Pressure Vessel Inspection discrepancies and failures
Boiler & Pressure Vessel Inspection discrepancies and failures Water Heaters / Pressure Vessels Pressure Vessels are inspected once every three years. This requires a test of A: safety relief devices B:
More informationSensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved.
Sensi TM Wi-Fi Programmable Thermostat MANUAL OPERATION Version: March 2016 2016 Emerson Electric Co. All rights reserved. Contents MANUAL OPERATION GUIDE Buttons and Icons 3 Basic Functionality 4 Manual
More informationService Manual Models: 502, 752, 1002, 1302,
PBX-PFX-SER Rev D Service Manual Models: 502, 752, 1002, 1302, 1501, 1701, and 2001 Up To 5:1 Turndown WARNING This manual must only be used by a qualified heating installer / service technician. Read
More informationService Manual Models: 80-285
KB-SER-08 Service Manual Models: 80-285 Starting Serial #H07H10040039 WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions, including this
More informationHorizontal Sterilizer MU 012.B / I (09/07) Page 2/46. 1 Index... 2
0932 Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46 1 Index 1 Index... 2 2 Description of the Inputs / Outputs... 4 2.1 Inputs / Module OMRON ID201 / ID211...4 2.2 Outputs / Module OMRON OC211...5
More informationINSTALLATION OPERATING & MAINTENANCE MANUAL
INSTALLATION OPERATING & MAINTENANCE MANUAL Basic Climatic TM Controller Ecologic English November 2002 CONTENTS PAGE GENERAL DESCRIPTION 3 USER INTERFACE 4 The keypad incorporated on the unit 4 The keypad
More informationImportant Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
More informationGNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.
Pellet Heater Owner's Manual Installation and Operating Instructions Please read this entire manual before installation. Save these instructions. SAFETY NOTICE HEATER MUST BE PROPERLY INSTALLED AND MAINTAINED
More informationELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009
Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25
More informationAN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
More informationNL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module
NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module 1. General Description 1 2. General Warnings 1 3. Interface 2 4. Temp Alarms Setting 3 5. Programming 3 6. Light Management 4 7. Installation and
More informationAIR CONDITIONER WALL CONTROLLER
AIR CDITIER WALL CTROLLER Operating Instructions Controller Model Numbers LM7 LM7-D LM4 Please Read This Manual Congratulations on your purchase of an ActronAir air conditioning system. This unit has been
More informationFor installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
More informationUser's Guide. CTS6000 WebControl
User's Guide CTS6000 WebControl Version 1.01, 29.06.2010 Contents Contents... 2 List of figures... 3 Introduction... 4 Introduction to CTS6000... 4 Reading instructions... 4 Quick startup... 5 Daily operation...
More informationBoilerMate SP. benchmark. user instructions A - C L A S S
A - C L A S S BoilerMate SP user instructions benchmark TM The code of practice for the installation, commissioning & servicing of central heating systems In the interest of continuously improving the
More informationPORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
More informationFeatures and Benefits
Refrigeration 2 eatures and Benefits Based on IR32 Parameters Real Time lock ( RT ) Model Specific (defrost based on real time 7 day 24 hour) HAP (Hazard Analysis and ritical ontrol Point) Alarm Available
More informationUSER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
More informationDUCT TYPE AIR CONDITIONER
OPERATING MANUAL OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES AIR CONDITIONER DUCT TYPE English Deutsch
More informationProduct Name LED Panel light Product Models
R Product Name LED Panel light Product Models MacoLEDs Panel-015 100W MacoLEDs Panel-015 100C Manual No:540-F690-10w MACOSTAR HONG KONG LTD 2/F.,Union Industrial Bldg.,48 Wong Chuk Hang Road,Hong Kong.
More informationDraining and filling cooling system
Page 1 of 9 Draining and filling cooling system Special tools and workshop equipment required Adapter -V.A.G 1274/8- Pipe -V.A.G 1274/10- Drip tray -V.A.G 1306- or drip tray for workshop hoist -VAS 6208-
More informationHEAT HEAT COOL HEAT PUMP COOL
OWNER S MANUAL RESIDENTIAL THERMOSTAT P/N P374-1800 HEAT COOL HEAT PUMP Su AUTO 0I20: Pm 74 COOL HEAT 27 7-DAY MABLE DIGITAL THERMOSTAT 3 Configurable Outputs Accepts Optional Humidity Module: Control
More information14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
More informationOverview - Danfoss Link and living software versions
Danfoss Link CC Mk II (with minisd card) software..35.3.7.4.5 0--00 The initial Danfoss Link CC software: Supports all features from the original Devilink software. New functionality providing control
More informationDUAL FUEL BURNERS GAS/HEAVY OIL
M A D E I N I TA LY SERIE KN 750/M_1000/M EL DUAL FUEL BURNERS GAS/HEAVY OIL BRUCIATORI MISTI GAS/OLIO COMBUSTIBILE All purpose heating solutions Soluzioni integrate per il riscaldamento All purpose heating
More informationVersion 1.0 09/10. Xerox ColorQube 9301/9302/9303 Administration and Accounting
Version 1.0 09/10 Xerox ColorQube 9301/9302/9303 2010 Xerox Corporation. All Rights Reserved. Unpublished rights reserved under the copyright laws of the United States. Contents of this publication may
More informationHEAT PUMP PROGRAMMABLE THERMOSTAT
HEAT PUMP PROGRAMMABLE THERMOSTAT SA PM 3 COOL TEMP Form 44014-01 r010408 Model 43168 Owners Manual 1 Congratulations! Heat Pump Programmable Thermostat Model 43168 THERMOSTAT CONTROLS Switches & Buttons...15
More informationLuna 3 Comfort Troubleshooting Guide June 2008
Luna 3 Comfort Troubleshooting Guide June 2008 For Technical Assistance Call: (800)461-4657 WARNING! THIS DOCUMENT IS INTENDED ONLY AS AN EDUCATIONAL TOOL This Troubleshooting Guide, and the instructions
More informationCONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL
More informationPART 11: START-UP PROCEDURES FOR THE INSTALLER
PART 11: START-UP PROCEDURES FOR THE INSTALLER NOTICE It is important to note that the user can adjust the heat curve down by adjusting the central heating temperature to a lower setting. 212 CENTRAL HEATING
More informationPC SERIAL INTERFACE FOR LAMBDA GAS CONTROL LGC-700
PC SERIAL INTERFACE FOR LAMBDA GAS CONTROL LGC-700 INDEX 1- Introduction 2- AGI-PRO Program Set-up 3- AGI-PRO Program Use 3.1- Interface Link 3.2- How Start AGI-PRO program 3.2-1. Page MONITOR 3.2-2. Page
More informationTICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System
TICS - Total Integrated Control Strategy Mid Range System Underfloor Heating & Cooling Control Solutions Energy efficient Heating and cooling TICS - Mid Range System Mid Range System TICS Mid Range Install
More informationProgrammable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify
Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify TABLE OF CONTENTS About your new thermostat Features...2
More informationOilonChooser Operating Instructions
OilonChooser Operating Instructions 1. Menu display and structure OilonChooser s menu display shows the data input field in the central area. The navigation bar is located in the left column. It shows
More informationTABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C
Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the
More informationUser Manual. Gas fired condensing wall hung boiler. G.C.N : 41-116 - 30 (12 kw) G.C.N : 41-116 - 31 (18 kw) G.C.N : 41-116 - 32 (24 kw)
User Manual Gas fired condensing wall hung boiler G.C.N : 41-116 - 30 (12 kw) G.C.N : 41-116 - 31 (18 kw) G.C.N : 41-116 - 32 (24 kw) CLAS HE R 12 CLAS HE R 18 CLAS HE R 24 Country of destination GB, IE
More informationUser's Instructions. Alpha HE CB25/33 and HE SY25
User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:
More informationOverheating limit control
Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating
More informationElectric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
More informationLiebert Deluxe System/3
Precision Cooling For Business-Critical Continuity Liebert Deluxe System/3 Operation and Maintenance Manual 50 and 60 Hz, 6-30 Ton DX Systems (DH/DE/VH/VE); 12-60 Ton CW Systems (FH/UH) TABLE OF CONTENTS
More informationInstallation, use and maintenance manual. Heating Boiler
Installation, use and maintenance manual Heating Boiler model : 484270010-EN_10/12 Hardware - M Read the instructions carefully before installation, use and maintenance. The manual is an integral part
More informationUSER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
More informationAutomation System TROVIS 5100 Ventilation Controller TROVIS 5177
Automation System TROVIS 5100 Ventilation Controller TROVIS 5177 ounting and Operating Instructions EB 5177 EN Electronics from SASON Firmware version 1.05 Edition September 2000 Contents 1 Scope of the
More informationHow To Set The Sensor On A Powerpoint 3.5 (Powerpoint) On A Blackberry 2.5A (Powerplant) On An Iphone Or Ipad (Powerplant) On The Blackberry 3.2 (
VMBGPOD Touch panel with Oled display for VELBUS system 1 Binairy format: bits Description
More informationUSERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book
USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
More informationBlue Easy Reader Thermostat 1F95EZ-0671. Homeowner s Guide
Blue Easy Reader Thermostat 1F95EZ-0671 Homeowner s Guide Message to Homeowners Congratulations on choosing the Emerson Blue Easy Reader Thermostat. Blue Easy Reader is designed to be the easiest thermostat
More informationTo suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)
OPERATION MANUAL Split System Ducted Air Conditioner To suit Daikin FDY "F" Series and FD "F" Series AIR CONDITIONER A hr o C (and other models incorporating BRC1B62/52 Remote Controller) Dear Owner, Thank
More informationContents. Introduction
TION Contents Introduction...1 Basics...2 Main Menu Structure...3 Time Schedule Menu...4 Settings Menu...5 Reports Menu...6 Date / Time Adjustment Menu...7 Introduction TION is an advanced control device
More informationVolkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)
19 Engine - Cooling System (Page GR-19) Cooling system draining and filling general information Body components, layout Engine components, layout Radiator fan run-on checking Recommended mixture ratios
More informationPortable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
More informationMode Switch. Fan Switch Menu button Program button
Operation 3M-30 Day Time of day Target Temperature Time Slot Touch Screen Current Room Temperature Thermostat Mode Statement of use: The 3M-30 can be used with millivolt, 24VAC, single and 2 stage conventional
More informationMulti-information Display (see MID )
Driving Position Memory (see Seats ) Power Mirrors (see Mirrors ) Indicators/Gauges (see Instrument Panel ) Multi-information Display (see MID ) HomeLink (see HomeLink ) Navigation System (see Navigation
More informationSingle Zone LCD Thermostat Operating Instructions
Fan Cool Furnace *Heat Pump or Heat Strip On/Off F Single Zone LCD Thermostat Operating Instructions MODEL 3313192.XXX Cool/Furnace 3313193.XXX Cool/Furnace/Heat Pump 3313194.XXX Cool/Furnace/Heat Strip
More informationAutomatic air conditioning system (with the Lexus Display Audio system)
Automatic air conditioning system (with the Lexus Display Audio system) Air outlets and fan speed are automatically adjusted according to the temperature setting. To display the air conditioning operation
More informationUNDERSTANDING CENTRAL HEATING SYSTEMS
UNDERSTANDING CENTRAL HEATING SYSTEMS This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential basic
More informationHeat Pump Water Heater IOM Manual
Heat Pump Water Heater IOM Manual Installation Operation & Maintenance This manual is intended as an aid to qualified service personnel for proper installation, operation and maintenance of the heat pump
More informationCM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?
WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?...an explanation for householders A programmable room thermostat is both a programmer and a room thermostat. A programmer allows you to set On and Off time periods
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationAir Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
More informationA Class Air Source Heat Pump User Guide
A Class Air Source Heat Pump User Guide IMPORTANT THIS MANUAL MUST BE LEFT WITH THE USER AFTER INSTALLATION 8/60476/0 Issue 1.03 Contents 1: Introduction 1 2: How the Heat Pump Works 1 2.1 Tips and advice
More informationApplication Engineering
Application Engineering February 2011 Electronic Unit Controller Table of Contents 1. Introduction and Features... 2 1.1 Technical Specifi cations... 3 1.2 Pressure Probe Error Bypass... 3 1.3 Bump Start...
More informationFactory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
More informationsip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved
Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section
More informationCM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET
CM702 PROGRAMMABLE THERMOSTAT FEATURES Attractive slim, modern styling makes it ideal for location in any type of home. 24-hour heating program. Up to 4 daily independent time and temperature level changes
More informationEnergy Efficiency HOSPITALITY. www.energia.ie
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
More informationSECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
More informationT-100-R Installation Guide
T-100-R Installation Guide Table of Contents Page 2 Overview T-100-R Z-Wave Thermostat 3-4 Installation HVAC System Setup 6 Installer Settings Menu Items 7-9 Installer Settings Summary 10-11 Wiring Standard
More informationUser Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler
You can rely on User Guide and Important Warranty Information Heatmax Combi HE Range Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over
More information4 Alarm and info. Alarm. Yes Warning. No Information No Reset alarms > No Current list > Alarm log list > Delete alarm log > No
6. 6.1 and info (Menu 4) NB are shown in the event of unit faults or irregular operation Check the Current list (Menu 4) for alarm messages and refer to the list of alarms given at the end of these instructions.
More informationSpecifications IDROFOX
Specifications IDROFOX Dear Sir or Madam, thank you for choosing our Idrofox stove. Before using your stove, please read this booklet carefully: it explains how to exploit all its features to the full
More informationUser and installation manual
User and installation manual aquaero 5 The information contained in this manual is subject to change without prior notice. All rights reserved. Current as of April 2011 ENGLISH: PAGE 1 DEUTSCH: SEITE 13
More information