BETA Measuring Single-Phase Measuring Devices
|
|
- Tabitha Jefferson
- 7 years ago
- Views:
Transcription
1 BETA Measuring /2 Product overview /3 7KT1 14 E-counters /5 7KT1 11, 7KT1 digital measuring devices /7 7KT1 0 analog measuring devices /8 7KT5 8 time and pulse counters /10 7KT5 5, 7KT5 6 time counters for front-panel mounting Siemens ET B1 10/2008
2 BETA Measuring Product overview Overview Devices Page Field of application Standards Used in 7KT1 14 E-counters /3 For the measurement of kwh in singlephase systems, e.g. in industrial plants, offices and apartments in apartment houses EN , EN , EN Non-residential buildings Residential buildings Industry 7KT1 11, 7KT1 digital measuring devices /5 Voltage and current measurement with large 3-digit LEDs for monitoring incoming and outgoing currents as well as device currents in order to prevent plant overload. DIN , DIN KT1 0 analog measuring devices /7 Voltage and current measurement for monitoring incoming and outgoing currents as well as device currents in order to prevent plant overload. IEC , EN KT5 8 time and pulse counters /8 For monitoring operating hours and starting operations for planning preventative maintenance tasks and preventing sudden shutdowns IEC , EN , (VDE ), UL 94 7KT5 5, 7KT5 6 time counters for front-panel mounting /10 For monitoring operating hours and starting operations for planning preventative maintenance tasks and preventing sudden shutdowns. IEC , EN (VDE ) /2 Siemens ET B1 10/2008
3 BETA Measuring 7KT1 14 E-counters Overview E-counters serve the measurement of kwh in single-phase systems, e.g. in industrial plants, offices and apartments in apartment houses. Benefits The accuracy class 1 according to EN ensures that you always have the correct measured value The drum-type register in digit size 3.8 mm 1.5 mm enables easy reading The short-circuit resistant pulse output protects the device if it is assembled incorrectly. Technical specifications 7KT1 140 Standards EN , EN , EN Supply Rated control voltage U n VAC 230 Operating range V Rated frequency Hz 50/60 Operating frequency range Hz Rated power dissipation P v W 0.6 Measuring inputs Connection type Direct Voltage V 230 Operating range voltage V Current A 75 Operating range current Direct connection A Minimum operational current ma 25 Frequency Hz 50/60 Operating frequency range - Distortion factor 3 %; symmetric sinus curve Hz Overload capability Voltage U e Continuous: phase/n V 276 Short-time (1 s) V 300 Current I e Continuous A 75 Short-time (10 ms) A 2250 Display Rate 1rate Active energy Drum-type register H W: mm mm digit with 1 decimal Measuring accuracy At 23 C ±1 C Active energy Acc. to EN % ±1 Safety Acc. to EN Separation of current and voltage circuit Electrical Rated insulation voltage V 300 Rated impulse withstand voltage 1.2/50 μs kv 6 Overvoltage category 4 Pulse output S0 interface acc. to EN IR test output LED Imp/kWh 1000 Terminals, output Imp/kWh 10 Pulse duration ms 100 ±5 Minimum interval between 2 pulses ms 5 Required voltage V DC Permissible current ma 90 Terminals Main current paths ± screw (Pozidriv) 2 S0 interface/control terminals Blade for slotted screw mm Conductor cross-sections, main current paths Conductor cross-sections S0 interface/control terminals Ambient conditions Rigid mm Flexible, with end sleeve mm Rigid mm Flexible, with end sleeve mm Temperature Storage C Operation C Relative air humidity Storage % 80 Operation % 80 Maximum vibration Sinus amplitude at 50 Hz mm ±0.075 Degree of protection IP20, with connected conductors Siemens ET B1 10/2008 /3
4 BETA Measuring 7KT1 14 E-counters Selection and ordering data U c I e U e MW DT Order No. Price PG PU PS*/ P. unit Weight approx. VAC AAC VAC Unit(s) Unit(s) kg E-counters for active energy With 7-digit drum-type register, with S0 interface, for single-phase operation Direct connection, single rate B 7KT Dimensional drawings L1 L1 N I2_ KT1 140 Schematics T1 1 3 kwh L1 L1 N I2_ A L1 N 230 V AC 7KT1 140 /4 Siemens ET B1 10/2008 * You can order this quantity or a multiple thereof.
5 BETA Measuring 7KT1 11, 7KT1 digital measuring devices Overview These devices for measuring voltages and currents can be used for monitoring input and output currents or device currents in electric plants. They are suitable for direct connection in a single-phase system or for three-phase systems when used in conjunction with a measuring selector switch. The measuring ranges of the ammeter are set at the device with a coding switch. Benefits The ammeters have 14 measuring ranges from A to A, which can be set using a coding switch. This ensures universal application. Technical specifications 7KT KT1 0 Standards DIN , -2 Rated control supply voltage U c VAC 230 Operating range U c Rated frequency Hz Rated operational power P s VA <2 Measuring range Voltage Direct measurement V AC Current Direct measurement A AC direct Transformer measurement A AC /5 Display 3 LED red; height 10 mm Voltage >600V HHH -- <V Current Direct > 20 A -- HHH Transformer > 5 A -- HHH Direct < 0.4 A Transformer < 0.1 A Measuring cycle /s 4times Measuring accuracy At 23 C % ±0.5 ±1 digit Temperature influence %/ C ±0.03 Overload capability Voltage Continuous V Short-time for 1 s V Current Continuous, direct A Continuous, transformer A Short-time for 1 s, direct A Short-time for 1 s, transformer A Electrical isolation Clearances mm Creepage distances in the device mm Creepage distances on the printed board Printed boards not installed mm Test voltage 50 Hz, 1 min kv Terminals ± screw (Pozidriv) 1 Conductor cross-sections Rigid, max. mm 2 1 6/2 4 Flexible, with end sleeve, min. mm Permissible ambient temperature C Degree of protection IP20, with connected conductors Siemens ET B1 10/2008 /5
6 BETA Measuring 7KT1 11, 7KT1 digital measuring devices Selection and ordering data U e I e U c MW DT Order No. Price PG PU PS*/ P. unit Weight approx. VAC AAC VAC Unit(s) Unit(s) kg Digital voltmeters B 7KT Digital ammeters for direct and transformer connection transformer /5 2 B 7KT Dimensional drawings I2_07806b 7KT1 110, 7KT Schematics Switching examples V AC L N 230 V AC max. 600 V AC L1 N L2 N 230 V AC L N N 230 V AC L1 N L2 N 230 V AC L1 N L KT1 110 I2_07833b 7 KT1 110 I2_07834c 7 KT1 0 Direct connection up to 20 A I2_07835c 7 KT1 0 Direct connection of different phases up to 20 A I2_07836c 7 KT1 0 I2_07837c Transformer connection Transformer /5 A Digital voltmeters Digital ammeters More information Range selector switch for 7KT1 0 digital ammeter Direct measurement A AC 0 Transformer measurement /5 A AC /5 A AC /5 A AC /5 A AC /5 A AC /5 A AC I2_00183c /5 A AC /5 A AC /5 A AC /5 A AC /5 A AC /5 A AC /5 A AC /5 A AC /6 Siemens ET B1 10/2008 * You can order this quantity or a multiple thereof.
7 BETA Measuring 7KT1 0 analog measuring devices Overview These devices for measuring voltages and currents can be used for monitoring input and output currents or device currents in electric plants. They are suitable for direct connection in a single-phase system or for three-phase systems when used in conjunction with a measuring selector switch. Benefits The 7KT1 020 ammeters can be equipped with changeable scales for primary currents of 60, 150 or 400 A AC, depending on the transformer ratio of the installed current transformer. The changeable scales are included in delivery. This ensures universal application Permanent overload up to 20 % does not damage the device. Protection for your plant. Technical specifications 7KT KT KT1 020 Standards EN Measuring ranges Direct measurement VAC AAC AAC AAC Transformer measurement AAC /5 Max. permissible measuring frequency Hz Display Pointer Measuring accuracy At 23 ±1 C % ±1.5 ±3 ±1.5 Rated operational power P s VA <2 <1.1 Temperature influence %/ C ±0.03 Overload capability Continuous 1.2 U meas 1.2 I meas Short-time for 1 s 2 U meas 10 I meas Test voltage 50 Hz, 1 min kv >2 Terminals ± screw (Pozidriv) Conductor cross-sections Rigid, max. mm 2 1 6/ / /2 4 Flexible, with end sleeve, min. mm Permissible ambient temperature C Degree of protection IP20, with connected conductors Selection and ordering data U meas I meas MW DT Order No. Price PG PU PS*/ P. unit Weight approx. VAC AAC Unit(s) Unit(s) kg Analog voltmeters B 7KT Analog ammeters for direct connection 25 4 B 7KT B 7KT B 7KT Analog ammeters for transformer connection with 3 different interchangeable scales A, A and A / / /5 4 B 7KT Dimensional drawings Schematics Terminals I2_11611b 7KT KT1 01., 7KT KT KT1 01., 7KT1 020 * You can order this quantity or a multiple thereof. Siemens ET B1 10/2008 /7
8 BETA Measuring 7KT5 8 time and pulse counters Overview Time and pulse counters are used for the reliable monitoring of production and service times, which enables the exact planning and monitoring of production sequences, maintenance cycles and warranty times. As well as the proven electromechanical time and pulse counters for mounting in distribution boards, we also supply digital time and pulse counters. The fields of application for both counter types are very diverse, such as the recording of operating hours of machines, systems or building management systems, as well as pulse counting for general volume flow counting, registration of starting frequencies, starting cycles or production quantities in systems and machines. Technical specifications Benefits Time and pulse counters help to plan maintenance intervals and ensure high plant availability Versions without zero position and with electric or manual zero position for all applications Flexible application of the digital counters for power supplies of to 150 V DC and 24 to 240 V AC in a single device. 7KT KT KT KT KT KT5 807 Standards DIN VDE ; EN ; UL 863 Approved acc. to UL 863, UL File No. E300537, CSA C22.2 No. 6 and 55 Rated control supply voltage U c VAC VDC Operating range At 50/60 Hz U c Rated frequency Hz Rated power dissipation P v VA <1 <2 Method of operation Counting of Hours Display Drum-type register h Terminals ± screw (Phillips) 1 Conductor cross-sections Rigid mm Flexible, with end sleeve, min. mm Permissible ambient temperature C Degree of protection Acc. to EN IP20, with connected conductors Safety class Acc. to EN 61140/VDE II Permissible humidity % <80 7KT KT5 8 7KT KT KT KT KT5 833 Standards DIN VDE ; EN ; UL 863 Approved acc. to UL 863, UL File No. E300537, CSA C22.2 No. 6 and 55 Rated control supply voltage U c VAC VDC Operating range At 50/60 Hz U c Rated frequency Hz -- 50/60 Rated power dissipation P v VA <1 <2 <1 Method of operation Counting of Pulses Hours Pulses Display Drum-type register LCD h Counting frequency Hz Pulse duration ms Resetting Electrical -- Yes Mechanical -- Yes Terminals ± screw (Phillips) 1 Conductor cross-sections Rigid mm Flexible, with end sleeve, min. mm Permissible ambient temperature C Degree of protection Acc. to EN IP20, with connected conductors Safety class Acc. to EN 61140/VDE II Permissible humidity % <80 /8 Siemens ET B1 10/2008
9 BETA Measuring 7KT5 8 time and pulse counters Selection and ordering data U c Frequency MW DT Order No. Price PG PU PS*/ P. unit Weight approx. V Hz Unit(s) Unit(s) kg Time counters Mechanical counting mechanism, display h without zero position DC -- 2 A 7KT AC 50 A 7KT AC B 7KT AC A 7KT AC 60 B 7KT AC B 7KT Pulse counters Mechanical counting mechanism, display without zero position DC -- 2 B 7KT AC 50/60 B 7KT AC B 7KT Electronic time counters LCD h without zero position DC, AC With electrical zero positioning DC, AC -- 50/ /60 With electrical and mechanical zero positioning Electronic pulse counters LCD DC, AC -- 50/60 With electrical and mechanical zero positioning DC, AC -- 50/60 2 B 7KT B 7KT B 7KT B 7KT Dimensional drawings Schematics Terminals 2(+) 2(L) I2_189a 7KT KT KT KT KT KT (-) 3(N) 7KT KT5 8 7KT KT KT KT KT /~ /~ L1(+) N( ) Count +/~ /~ L1(+) N( ) Count Reset K1 K1 K I2_11616b I2_188b 7KT KT5 822, 7KT5 823, 7KT5 833 More information Time counters count the time in hours with an accuracy of two decimal places (hundredths of an hour). The pulse counter sums up the number of pulses, e.g. the making operations of devices. A power supply is required at terminals 1 and 3 of the electronic counters so that the device can constantly display the measured values. Once terminal 3 is supplied with voltage (for DC "+"), the counting procedure starts. If terminal 4 is supplied short-time with voltage (for DC "+"), the counter is reset. In the case of electronic counters, the counting result is saved indefinitely in the event of a power failure (EEPROM). On recovery of the power, the counting is continued from the saved value. As well as a modern design, the electronic counter has a 7-digit LCD, which can be reset electrically or manually. * You can order this quantity or a multiple thereof. Siemens ET B1 10/2008 /9
10 BETA Measuring 7KT5 5, 7KT5 6 time counters for front-panel mounting Overview Time and pulse counters for control cabinets, control and mechanical engineering are used, e.g. in boilers, machine tools or compressors. The pulse counters count the starting frequencies. This supports planning for preventative maintenance. In-time and regular maintenance is the best protection against unexpected shutdowns. Time counters count the time in hours with an accuracy of two decimal places (hundredths of an hour). Benefits Time and pulse counters help to plan maintenance intervals and ensure high plant availability. Technical specifications 7KT KT KT KT KT KT5 505 Standards DIN VDE ; EN Rated control supply voltage U c VAC VDC Operating range U c Rated frequency Hz Rated power dissipation P v VA < Method of operation Counting of Hours Display Drum-type register h Pulse duration Pulse length, pulse interval ms 50 Front-panel mounting Switchboard cutout Without cover 55 mm 55 mm mm mm With cover 55 mm 55 mm Ømm Terminals ± screw (Phillips) 1 Conductor cross-sections Rigid mm Flexible, with end sleeve, min. mm Permissible ambient temperature C Degree of protection Acc. to EN Front panel IP65 Installation with seal IP43 Terminals IP20, with connected conductors Safety class Acc. to EN 61140/ VDE II Permissible humidity % <93 7KT KT KT KT KT5 604 Standards DIN VDE ; EN Rated control supply voltage U c VAC VDC Operating range U c Rated frequency Hz Rated power dissipation P v VA <1 Method of operation Counting of Hours Display Drum-type register h Pulse duration Pulse length, pulse interval ms 50 Front-panel mounting Switchboard cutout mm mm Terminals ± screw (Phillips) 1 Conductor cross-sections Rigid mm Flexible, with end sleeve, min. mm Permissible ambient temperature C Degree of protection Acc. to EN Front panel IP52 Terminals IP00 Safety class Acc. to EN 61140/ VDE II Permissible humidity % <93 /10 Siemens ET B1 10/2008
11 BETA Measuring 7KT5 5, 7KT5 6 time counters for front-panel mounting Selection and ordering data U c Frequency MW DT Order No. Price PG PU PS*/ P. unit Weight approx. V Hz Unit(s) Unit(s) kg Time counters Mechanical counting mechanism, display h, For front-panel mounting, front frame 48 mm 48 mm DC A 7KT AC 50 A 7KT AC A 7KT AC A 7KT AC 60 A 7KT AC A 7KT For front-panel mounting, front frame 72 mm 72 mm With narrow frame according to DIN DC 2 B 7KT AC 50 B 7KT AC A 7KT AC 60 B 7KT AC B 7KT Covers for 7KT5 5 time counters 55 mm 55 mm B 7KT Sealing rings for 7KT9 020 covers IP43 installation in switchboards, C 7KT set 1 set with smooth surfaces (1 set = 5 units) Terminal covers for 7KT5 6 time counters Degree of protection, IP20, with connected conductors B 7KT Dimensional drawings Schematics Terminals ,5 5,5 34 I2_07089b 5, I2_06021b 7KT5 5, 7KT5 6 7KT5 5 7KT5 6 * You can order this quantity or a multiple thereof. Siemens ET B1 10/2008 /11
12 BETA Measuring Notes / Siemens ET B1 10/2008
BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
More informationRISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationBETA Protecting SITOR Semiconductor Fuses
BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More information3-phase, bidirectional energy meter
Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationDigital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7
Energy Meters INDEX 1 Measurement Digital single-phase Energy-meters Direct till 32 A 1 module DIN page 5 Digital single-phase Energy-meters Direct till 45 A 1 module DIN page 6 Digital single-phase Energy-meters
More informationPanel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationPreset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationControl Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationPluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
More informationMaximum Demand Control
Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationSwitching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches
Siemens AG 2014 Switching Devices /2 Introduction /5 5TE control switches / 5TE4 pushbuttons /11 5TE5 light indicators /13 5TE On/Off switches /20 5TE DC isolators /22 5ST busbars for modular installation
More informationEnergy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
More informationTechnicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationSPST-NO SPDT DPST-NO DPDT
PCB Relay Next-generation PCB Relay Available in 2 Models Low profile:. mm max. in height Contains no lead inside and features cadmium-free contacts ensuring environment-friendly use. Conforms to VDE0
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More information5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
More informationActuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More informationH/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
More informationDEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
More information1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) HIGH INSULATION Insulation distance (between coil and
More informationType: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationPHOENIX CONTACT - 2012-12-14. Features
Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed
More informationADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationSINEAX U553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
More informationPOWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES
POWER RELAY POLE - 6A / Inrush 20A relay FTR-K-KS Series FTR-K SERIES FEATURES pole 6A, form A or form C Peak inrush current 20A / TV-8 Coil power 400mW High insulation in small package (between coil and
More informationHSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationTechnical data UNIBLOCK UBSF 180 625
Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power
More informationRelés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationUser Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
More informationType: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
More informationThroughbeam photoelectric sensors. Dimensioned drawing. Electrical connection
Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationProduct and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
More informationSURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
More informationPower Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
More informationVEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
More informationDS 600. A contact free flux gate based current measurement sensor 600A rms
DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum
More informationE-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection
More informationDRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
More information3-Phase Energy meter with serial S-Bus interface
Data sheet www.sbc-support.com 3-Phase Energy meter with serial S-Bus interface Energy meters with an integrated S-Bus interface allow direct reading of all relevant data, such as energy (Total and partial),
More informationAmmeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
More information2 POLES - 5A LOW PROFILE TYPE
FTR-K1 SERIES POWER RELAY 2 POLES - 5A LOW PROFILE TYPE FTR-F1 Series FEATURES Low profile (height: 16.5mm) DPST/DPDT 5A, TV-3 rating available High insulation (due to its reinforced insulation construction)
More informationApplication Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)
Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationPower Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
More informationRoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,
APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP
More information1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES
POWER RELAY 1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES RoHS compliant FEATURES Ultra slim type with 5 mm thickness Good for high density mounting Low power consumption and high sensitivity Nominal
More informationAmmeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
More informationAnalogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
More informationLaser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More information1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) High insulation Insulation distance (between coil and
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),
More informationE-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous
More informationThyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
More informationContact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
More informationEmergency lighting units EM powerled
M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More informationMONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA
w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions
More informationContact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationAUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
More informationPCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v
Short circuit PCB transformer General Data Rated input 230 Vac Rated output 6-2 x 24 Vac Rated power 0.35-3.2 VA Insulation class B Maximum ambient temperature 70 C Efficiency up to 58 % Degree of protection
More informationSILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES
FTR-K1 SERIES SILENT POWER RELAY 1 POLE - 78A/120A Inrush Current Type FTR-H3 Series FEATURES Pin compatible with widely used VS and FTR-H1 series power relays Silent relay with patented unique U-shape
More informationMultifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More information650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
More informationE-STOP relays, safety gate monitors
Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More information1 POLE - 8A Medium Load Control
POWER RELAY 1 POLE - 8A Medium Load Control JS Series FEATURES UL class B (130 C) coil wire insulation 1 form A (SPST-NO) or 1 form C (SPDT) contact Low profile and space saving - Height: 12.5 mm - Mounting
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More information1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
More informationPolyphase kwh Electricity Meter
Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2
More informationPower Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
More informationTRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,
More informationBimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
More information1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C
FTR-K1 SERIES POWER RELAY 1 POLE - 16A / Inrush 120A relay FTR-K1-KS Series FEATURES 1 pole 16A, 1 form A or 1 form C Peak inrush current 120A / TV-8 Coil power 400mW High insulation in small package (between
More information