Smoke Extraction Motors Cast Iron Frame Improved Efficiency EFF2 Standard Features:
|
|
- Audrey McDaniel
- 7 years ago
- Views:
Transcription
1 Smoke Extraction Motors Cast Iron Improved Efficiency EFF2 Standard Features: Motors Energy Automation Coatings Three-phase, multivoltage, IP55, TEFC : 0.15 up to 330 s: up to 355M/L Voltage: /3-415V (up to ) 3-415/660V (from 112M and up) Class F insulation ( T=K) Continuous duty: S1 Design N Ambient temperature: 40 C, at 1000 m.a.s.l. Squirrel cage /Aluminium die cast Enclosure: TEFC or TEAO Pad mounted model: frame sizes up to 250 (132M/L and 1M are not available) Foot mounted model: frame sizes up to 355 Construction form: B3 (B30 for Pad Mounted Motors) Labyrinth seals (except 200 C/2 hours motors) Krytox (Except 200ºC/2 hours motor) Drain Plug One meter long flying leads for pad mounted motors (without terminal box) Regreasing Nipple for frame: 160 and up (300ºC/1 hour and 400ºC/2 hours) 225 and up (200ºC/2 hours Painting provided with modified Phenolic Resin Color - Aluminium Options available, on request. Typical Applications: These motors are used where a large concentration of people in commercial and industrial facilities is present: Large buildings, Shopping malls, Factories, Warehouses, Enclosed parking lots Other ventilation systems Service Certification F200 F300 F400 S1-40ºC S1-40ºC S1-40ºC S2* - 200ºC - 2 hours S2* - 300ºC - 1 hour S2* - 400ºC - 2 hours BSRIA - U.K. s: 132 to 2 BSRIA - U.K. s: to 250 Also avaiable certification for 300º C/2 hours BSRIA - U.K. s: to 1 CTICM - France s: 90 to 2 Pole: IV, VI, VIII, VI/IV, VII/Vpoles Insulation Class Ins. Class F; Temp. Rise K Ins. Class H; Temp. Rise K or 105K Standard EM Pole / Sizes II, IV/II pole (frame sizes up to 250) available IV, VI, VIII/IV, VI/IV pole ( frame sizes up to 355M/L) Construction TEFC or TEAO (Foot or flange mounted / pad mounted for frame sizes up to 250)
2 Features and Benefits Bearings WEG motors are fitted with the highest quality bearings selected from the best manufacturers in the world and designed to ensure long life of the motor even under heavy operating conditions. For motors supplied with high temperature grease, bearings are designed to meet critical operating conditions. WEG uses Krytox Grease that provides protection from rusting, high-temperature corrosion and antiwear. Krytox allows extended lubrication intervals. Endshield Made of cast iron offering a superior mechanical strength, corrosion-resistance and extended lifetime. WEG motors are made of FC-200 high-grade cast iron (same density as flameproof motors). The frames are provided with fins aiming at improving the heat dissipation and adequately spaced to minimize air blockage due to accumulation of dirt. The assemby system is prepared for direct installation in ventilation ducts. The motors can be mounted in either horizontal or vertical positions. Terminal Box Motor supplied with terminal box base and extended leads (1 meter) allowing lead connection outside of the duct. Loose terminal box and longer power supply leads can also be supplied. Nameplate Stainless steel nameplate ensuring a permanent record of all motor data. Rotor High pressure die cast dynamically balanced, thus reducing vibrations. Stator Built with low magnetic loss steel lamination reducing losses and operating temperature. Drain Hole Provided with plastic drain plug allowing drainage of condensed water. Winding The insulation system of the winding has been specially selected and tested to ensure that it will withstand the extreme temperature during the emergency period. The windings are impregnated with dipping and baking process (frames up to 200L) and continuous resin flow process (frames up to 355M/L). For 300 C/1hour and 400 C/2 hours motors WEG uses special wire and special varnish impregnation. Shaft WEG uses SAE/AISI 1040/45 carbon steel as standard, which provides high mechanical strength, preventing bending under load and minimizes fatigue which extends lifetime. Specially designed to withstand s caused during motor acceleration and deceleration. Upon special design motor, shaft can have second shaft end. Endshields Made of cast iron, they are provided with external fins for better heat dissipation, thus increasing bearing life. Seals WEG motors (300 C/2 hours and 400 C/2 hours) are fitted with Taconite Labyrinth seals to provide a good protection in dusty and high moisture environments. Low Voltage Motors 137
3 Smoke Extraction Motors Cast Iron - Single Speed C/2 hours Improved Efficiency EFF2 / II Pole rpm / / S / L M / S S / / L / M 1) / L / L / / S/M / / S L* / M / M* M / L* / L* IV Pole rpm / / S / L / / M S / M / L / M1) L / L / / S/M / S/M / S/M / / / / M/L / M/L / M/L / M/L / / S L* M* S M/L*2) / L* M1) / M / L / / S/M S/M / S/M / * / Notes: *Class F insulation with T105K Standard voltage, connection and frequency: V 50Hz 3-415V 50Hz 3-415V Y 50Hz V Y 50Hz The values shown are subject to change without prior notice. To obtain guaranteed values please access our website. locked db Efficiency Power Factor (Cos 138 Low Voltage Motors
4 Smoke Extraction Motors Cast Iron - Single Speed C/2 hours Improved Efficiency EFF2 3 V 415 V Efficiency Power Factor (Cos Efficiency Power Factor (Cos II Pole rpm IV Pole rpm ) For Pad Mounted, please consider frame size 1L. 2) size 132M/L is not available for Pad Mounted. For Pad Mounted version frame sizes up to 250S/M. Low Voltage Motors 139
5 Smoke Extraction Motors Cast Iron - Single Speed C/2 hours Improved Efficiency EFF2 / locked Efficiency Power Factor (Cos VI Pole rpm / / S / L / M / S M M / / L / L / L / L / S/M S/M / S/M / M/L / M/L / M/L / M/L / M/L* / M / S S/M S/M * / VIII Pole rpm / / S / L / / / M / S / M / / / L / L L / / / S/M / S/M / S/M / / / M/L / M/L / M/L / M/L / / S/M / S/M / db Notes: *Class F insulation with T105K Standard voltage, connection and frequency: V 50Hz 3-415V 50Hz 3-415V Y 50Hz V Y 50Hz The values shown are subject to change without prior notice. To obtain guaranteed values please access our website. 140 Low Voltage Motors
6 Smoke Extraction Motors Cast Iron - Single Speed C/2 hours Improved Efficiency EFF2 3 V 415 V Efficiency Power Factor (Cos Efficiency Power Factor (Cos VI Pole rpm VIII Pole rpm ) For Pad Mounted, please consider frame size 1L. 2) size 132M/L is not available for Pad Mounted. For Pad Mounted version frame sizes up to 250S/M. Low Voltage Motors 141
7 Smoke Extraction Motors Cast Iron - Two Speed C/2 hours Improved Efficiency EFF2 - Variable IV/II Pole - Dahlander Winding / locked Efficiency Power Factor (Cos 50Hz - 400V - IV/II pole (1500/3000 rpm) - Y / YY connection / / S / L / M / / S / M / / / / L / / M 1) / / L / / L / db Notes: *Class F insulation with T105K Standard voltage, connection and frequency: V 50Hz 3-415V 50Hz 3-415V Y 50Hz V Y 50Hz The values shown are subject to change without prior notice. To obtain guaranteed values please access our website. 1) For Pad Mounted, please consider frame size 1L. 2) size 132M/L is not available for Pad Mounted. For Pad Mounted version frame sizes up to 250S/M. 142 Low Voltage Motors
8 Smoke Extraction Motors Cast Iron - Two Speed C/2 hours Improved Efficiency EFF2 - Variable VIII/VI Pole - Dahlander Winding / locked db Efficiency Power Factor (Cos 50Hz - 400V - VIII/IV pole (750/1500 rpm) - Y / YY connection / / / S / / L / / / M / S / / M/L 2) / / / / L / M 1) L L L* / / / S/M / S/M / / / / Low Voltage Motors 143
9 Smoke Extraction Motors Cast Iron - Two Speed C/2 hours Improved Efficiency EFF2 - Variable VI/IV Pole - Independent Winding / 50Hz - 400V - VI/IV pole (1000/1500 rpm) - Y / Y connection locked Efficiency Power Factor (Cos / / S / L / / / / M / S M / / / L / M 1) M 1) L L / / / S/M / S/M / / / / db Notes: *Class F insulation with T105K Standard voltage, connection and frequency: V 50Hz 3-415V 50Hz 3-415V Y 50Hz V Y 50Hz The values shown are subject to change without prior notice. To obtain guaranteed values please access our website. 144 Low Voltage Motors
10 Smoke Extraction Motors Cast Iron - Two Speed C/2 hours Improved Efficiency EFF2 - Variable IV/II Pole - Dahlander Winding / locked Efficiency Power Factor (Cos 50Hz - 400V - IV/II pole (1500/3000 rpm) - D / YY connection / S / L / / M / S / M / / L* / M 1) / / L / L / S/M / db 1) For Pad Mounted, please consider frame size 1L. 2) size 132M/L is not available for Pad Mounted. For Pad Mounted version frame sizes up to 250S/M. Low Voltage Motors 145
11 Smoke Extraction Motors Cast Iron - Two Speed C/2 hours Improved Efficiency EFF2 - Variable VIII/IV Pole - Dahlander Winding / locked Efficiency Power Factor (Cos 50Hz - 400V - VIII/IV pole (750/1500 rpm) - Δ / YY connection / / S L / / / M / S / / M/L 2) / / / / L / / L / / L / / / / S/M / / S/M / S/M / / / / / db Notes: *Class F insulation with T105K Standard voltage, connection and frequency: V 50Hz 3-415V 50Hz 3-415V Y 50Hz V Y 50Hz The values shown are subject to change without prior notice. To obtain guaranteed values please access our website. 146 Low Voltage Motors
12 Smoke Extraction Motors Cast Iron - Two Speed C/2 hours Improved Efficiency EFF2 - Variable VIII/IV Pole - Dahlander Winding / locked db Efficiency Power Factor (Cos 50Hz - 400V - VI/IV pole (1000/1500 rpm) - Y / Y connection / / / S L / M S M L / M 1) L L / / S/M / S/M / / S/M / / * ) For Pad Mounted, please consider frame size 1L. 2) size 132M/L is not available for Pad Mounted. For Pad Mounted version frame sizes up to 250S/M. Low Voltage Motors 147
13 Smoke Extraction Motors Cast Iron - Single Speed C/1 hour Improved Efficiency EFF2 / locked Efficiency Power Factor (Cos II Pole rpm / / S / L M / S S / / L / M 1) / L / L / / S L* / M / M* M / L* / L* IV Pole rpm / / S / L / / M S / M / L / M1) L / L / / S/M / S/M / S/M / / / / M/L / M/L / M/L / M/L / / S L* M* S / L* L / / S/M S/M / S/M / * / db Notes: *Class F insulation with T105K Standard voltage, connection and frequency: V 50Hz 3-415V 50Hz 3-415V Y 50Hz V Y 50Hz The values shown are subject to change without prior notice. To obtain guaranteed values please access our website. 148 Low Voltage Motors
W50 Three-Phase Electric Motor
Motors Automation Energy Transmission & Distribution Coatings W50 Three-Phase Electric Motor Technical Catalogue IEC Market W50 - The New Generation of WEG Motors for Heavy Duty Applications The W50 motor
More informationINSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check
More informationWound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP
Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP ABB The Preferred Partner Egypt Cement Corporation, a major cement manufacturer, has chosen ABB wound rotor motors for all key applications
More informationHorizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
More informationWe will discuss common industrial applications with guides for the proper use of electric motors on these.
INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which
More informationTransformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
More informationTHREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS AL SERIES
THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS AL SERIES IE2 FRAMES 80 355 0,75 315kW (1500rpm) FOR INVERTER DUTY Code Declaration of conformity The motors described in this catalogue satisfy the essential
More informationA S Y N C H R O N O U S M O T O R S
ASYNCHRONOUS M O T O R S S E R I E S INDAR ASYNCHRONOUS MOTORS S E R I E S WHO WE ARE Indar Electric s trajectory is endorsed by the construction of thousands of motors for the different industrial sectors.
More informationCatalog. Low voltage Water cooled motors
Catalog Low voltage Water cooled motors We provide motors and generators, services and expertise to save energy and improve customers processes over the total lifecycle of our products, and beyond. 2 Low
More informationCOOLING TECHNOLOGY INSTITUTE
PAPER NO: CATEGORY: TP09-18 FANS COOLING TECHNOLOGY INSTITUTE RECENT DEVELOPMENTS IN MOTOR TECHNOLOGY ALLOW DIRECT DRIVE OF LOW SPEED COOLING TOWER FANS ROBBIE MCELVEEN BILL MARTIN RYAN SMITH BALDOR ELECTRIC
More informationPump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationCRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html
More informationPump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationREVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)
SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY
More informationCE Marking to BS EN 12101-3
CE Marking to BS EN 12101-3 300ºC/2 Hrs, PWA range Foot mount motors Report Number 54594/3 Edition 2 This report supersedes Report Number 54594/3 dated 14 March 2011 Carried out for Pitsan By Mark Roper
More informationSingle-Phase AC Synchronous Generator
ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description
More informationRaising the waters. Lift irrigation is getting a boost from ABB s synchronous motors
Raising the waters Lift irrigation is getting a boost from ABB s synchronous motors JARI LINDSTRÖM, TAPIO RAUHALA, MAGNUS REJSTRÖM In India, the scarcity of water is unfortunately a harsh reality. Still,
More informationPermanent Magnet Technology within Direct Drive Cooling Tower Motors Creates System Energy Savings
Permanent Magnet Technology within Direct Drive Cooling Tower Motors Creates System Energy Savings Roman Wajda, Robbie McElveen, Bill Martin, and Steve Evon, Baldor Electric Company ABSTRACT At a time
More informationWEg Mod Shop Modification Program, Special Features & Spare Parts
INDEX & ACCESSORIES WEg Mod Shop Modification Program, Special Features & Spare Parts V-RING NON-DRIVE ENDSHIELD BEARING STATOR BEARING V-RING FAN COVER FAN FRAME ROTOR DRIVE ENDSHIELD TERMINAL BOX WEg
More informationTABLE OF CONTENTS INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES...
SYNCHRONOUS MOTORS TABLE OF CONTENTS Motores Síncronos INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES...11 CONSTRUCTIVE CHARACTERISTICS...12
More informationAC Electric Motors best practice
If you want to learn more about best practice machinery maintenance, or world class mechanical equipment maintenance and installation practices, follow the link to our Online Store and see the Training
More informationSIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
More informationAC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles
AC Induction Motors Simplest and most rugged electric motor Consists of wound stator and rotor assembly AC in the primary member (stator) induces current in the secondary member (rotor) Combined electromagnetic
More informationSINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006
SINGLE PHASE MOTORS INSTALLATION AND MAINTENANCE MANUAL March 21, 2006 Irvine, California (800) 474-0520 Indianapolis, Indiana (800) 866-7973 Hamilton, Ontario (800) 809-0330 e-mail: sales@sterlingelectric.com
More informationIntroduction. Upon completion of Basics of AC Motors you should be able to:
Table of Contents Introduction...2 AC Motors...4 Force and Motion...6 AC Motor Construction... 12 Magnetism... 17 Electromagnetism... 19 Developing a Rotating Magnetic Field...24 Rotor Rotation...29 Motor
More informationBaldor Electric Company Premium Efficiency Motor Specification Totally Enclosed Fan Cooled Motor 1-250 HP Rev June 6, 2001
Table of Contents 1.0 Purpose 2.0 Scope Baldor Electric Company Premium Efficiency Motor Specification Totally Enclosed Fan Cooled Motor 1-250 HP Rev June 6, 2001 3.0 Motor Requirements 3.1 Applicable
More informationFin-cooled motors for the oil, gas, chemical and petrochemical industries. Loher CHEMSTAR and Loher VARIO motors. Explosion-proof motors LOHER
Fin-cooled motors for the oil, gas, chemical and petrochemical industries Loher CHEMSTAR and Loher VARIO motors Explosion-proof motors LOHER Danger of explosion, aggressive atmospheres, frequently extreme
More information2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?
Extra Questions - 2 1. A straight length of wire moves through a uniform magnetic field. The e.m.f. produced across the ends of the wire will be maximum if it moves: a) along the lines of magnetic flux
More informationSECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
More informationPPA & PPC series motors High specification cast iron units
Edition 4 Issue 3 PPA & PPC series motors High specification cast iron units Accreditation No. 14396 SOLUTIONS, not just products Specialists in Electric Motors, Geared Motors & AC Drives At CMG we offer
More informationCRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
More informationCRK 2-130 A-W-A-BUBV 85805906
GRUNDFOS DATA BOOKLET CRK 2-13 A-W-A-BUBV 858596 Grundfos Pump 497113 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crk2/497113/crk-2-13-13-a-w-a-auuv.html
More informationBaldor Electric ProSPEC MASTERFORMAT SPECIFICATION May 3, 2005. A. This specification covers integral horsepower squirrel cage AC induction motors.
SECTION 16221 - TEFC AC INDUCTION MOTORS PART 1 - GENERAL 1.1 SUMMARY A. This specification covers integral horsepower squirrel cage AC induction motors. B. This specification is intended to specify superior
More informationMEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
More informationCDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100
CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL
More informationDéfumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.
Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally
More informationBaldor Electric Company Premium Efficiency Motor Specification Open Drip-Proof Motors 1-500 HP Rev June 6, 2001
Table of Contents 1.0 Purpose 2.0 Scope Baldor Electric Company Premium Efficiency Motor Specification Open Drip-Proof Motors 1-500 HP Rev June 6, 2001 3.0 Motor Requirements 3.1 Applicable Codes and Regulations
More informationICQ Series - square centrifugal
product ICQ Square Centrifugal (TEFC) dimensions mm 280-710 poles & duty 4-8 / up to 4,500 L/s application High performance centrifugal fans for medium to high pressure ducted systems. ICQ Series The ICQ
More informationInstallation, Operation and Maintenance Instructions
Installation, Operation and Maintenance Instructions for AC Induction Motors 56-6800 Frames (NEMA) 63 280 Frames (IEC) MARATHON ELECTRIC Contact Motor Customer Service at: Phone: (75) 675-33 www.marathonelectric.com
More informationRotary Phase Converters
FACTS from Ronk Electrical Industries, Inc. Bulletin 11981 Rotary Phase Converters ROTOVERTER Pat. No. 3,670,238 ROTO-CON Pat. No. 4,158,225 What are the ROTO-CON and ROTOVERTER power converters? The ROTO-CON
More informationMedium voltage Electric motors ELECTRICAL MACHINES UNIBOX & MS4
Medium voltage Electric motors ELECTRICAL MACHINES UNIBOX & MS4 Index - Medium Voltage Motor Series PRODUCT TOPIC ACTOM our company history Who is ACTOM PG UNIBOX Bearings and lubrication 7 UNIBOX Ventilation
More informationMultistage high-pressure multistage centrifugal pumps
Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,
More informationStandard offering (pumps)
MDM PUMPS LTD Spring Lane Malvern, Worcs. England. WR14 1BP This outlines what we typically supply. Tel: +44 (0)1684 892678 Fax: +44 (0)1684 892841 E-mail: Website: Standard offering (pumps) info@mdmpumps.co.uk
More informationProduct Brochure. Certified Mining Motors
Product Brochure Certified Mining Motors Profile Baldor Electric Company (a member of the ABB group) is a world leader in motors for the mining industry. In the continuous (24/7) operation of underground
More informationKTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet
KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationGeneral Information. ME-business can be accessed through: www. marathonelectric.com.
MARATHON ELECTRIC Since 1913, Marathon Electric s name has been recognized for engineering excellence, custom-designed products and an extensive product line of industrial quality motors. Available in
More informationAC METRIC (IEC) MOTORS THREE PHASE
AC METRIC MOTORS These high efficiency motors meet North American performance standards and EPACT energy efficiency mandates, and have.5 service factors. Typically used for replacement on machine tools,
More information3 Phase AC Induction Motors
3 Phase AC Induction Motors INSTALLATION AND OPERATION MANUAL August 21, 2015 Indianapolis, Indiana (00) 66-93 e-mail: sales@sterlingelectric.com www.sterlingelectric.com 93 Allison Avenue, Indianapolis,
More informationGE Power Conversion. Motors. Medium / High Voltage and High Speed 190 to 100,000 kw 250 to 134,000 HP
GE Power Conversion Motors Medium / High Voltage and High Speed 190 to 100,000 kw 250 to 134,000 HP 2 GE I Power Conversion GE has been setting the standard in manufacturing motors for over 125 years.
More informationUnit 33 Three-Phase Motors
Unit 33 Three-Phase Motors Objectives: Discuss the operation of wound rotor motors. Discuss the operation of selsyn motors. Discuss the operation of synchronous motors. Determine the direction of rotation
More informationMounting Instructions. Torque Transducer. A0329 3.2 en
Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................
More informationBRUSHLESS DC MOTORS. BLDC 22mm. BLDC Gearmotor Size 9. nuvodisc 32BF. BLDC Gearmotor Size 5
BRUSHLESS DC MOTORS BLDC Gearmotor Size 9 BLDC 22mm nuvodisc 32BF BLDC Gearmotor Size 5 Portescap Brushless DC motors are extremely reliable and built to deliver the best performances. Their high power
More informationWhy Baldor? Table of Contents. www.baldor.com
Pump Motors Why Baldor? Industry s shortest lead times/flexible manufacturing. Baldor has the industry s shortest lead times on custom motors just ten working days. Our unique LEAN FLEX FLOW manufacturing
More informationHow the efficiency of induction motor is measured?
How the efficiency of induction motor is measured? S. Corino E. Romero L.F. Mantilla Department of Electrical Engineering and Energy E.T.S.I.I. y T. Universidad de Cantabria Avda de Los Castros, 395 Santander
More informationSEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor
INSTALLATION, OPERATION AND MAINTENANCE MANUAL For SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor Yeomans Chicago Corporation 3905 Enterprise Court P.O. Box 6620 Aurora, IL 60598-0620 Phone:
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS
More informationWE-350 Series ¼ Turn Electric Actuator
WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information
More informationWhat Do All Those Things on an AC Motor Nameplate Mean?
What Do All Those Things on an AC Motor Nameplate Mean? Introduction: Ever order a motor on power, speed, and enclosure? PO says maybe "5 hp, 1,800 rpm, TEFC." New-motor nameplate says "HP 5, RPM 1748,
More informationSUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2
SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 APPROVED NO : APPROVED BY : (AUTHORIZED) SPEC.NO D600023 ISSUE DATE 08.06.1998 DAWN.
More informationPermanent Magnetic Generator Construction Manual
Permanent Magnetic Generator Construction Manual http://hojomotor.com Our Team Doing an On-site Assembly in Peru http://hojomotor.com Section 1) Introduction This manual describes how to build a 'permanent
More information"AC2EC" - Replacement made easy New EC motor design Compact and efficient
"AC2EC" - Replacement made easy New EC motor design Compact and efficient The efficiency of the fans used is a central issue in ventilation and airconditioning technology. This is encouraged not only by
More informationWater-cooled three-phase asynchronous motors. Type series K21B / K23B
Water-cooled three-phase asynchronous motors Type series K21B / K23B Contents Page Introduction 3 Standards and regulations 4 Design version 4 Water cooling 5 Degree of protection 5 Drain holes 5 Vibration
More information32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw
,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted
More informationFOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
More information1 Temperature Derating Guide
VLT HVAC Drive FC 02 Application Note Temperature Derating Guide Temperature Derating Guide.. Abstract This paper provides detailed data regarding the operation of the VLT HVAC Drive FC02 at varying ambient
More informationOUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd
OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd ACTOM OUTDOOR DISCONNECTORS Single Side Break (SSB) Disconnector 22-132 kv, 800-1 A, 25 ka - 3s Typical bearing assembly. Voltage range 11 kv to 132
More informationPaper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation
IOSR Journal of Engineering (IOSRJEN) ISSN (e): 2250-3021, ISSN (p): 2278-8719 Vol. 04, Issue 01 (January. 2014), V6 PP 01-12 www.iosrjen.org Paper on Basbar Trunking System for Electrical Supply to Industrial
More informationTurbo generators Best quality for thermal power plants
Turbo generators Best quality for thermal power plants www.andritz.com ANDRITZ HYDRO Turbo generators International technology Group ANDRITZ is a globally leading supplier of plants, equipment, and services
More informationMICRO HYDRO POWER GENERATING EQUIPMENT
MICRO HYDRO POWER GENERATING EQUIPMENT TOSHIBA TOSHIBA ENGINEERING In general, specifications of hydroelectric power system vary depending upon the installation location. The hydro turbine and generator
More informationLow Voltage Transformers Sealed, General Purpose, Dry Type
Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................
More informationA technical guide to Shell tactic emv
A technical guide to Shell Tactic EMV TABLE OF CONTENTS SECTION PAGES Introduction 3 Benefits of Short Re-Lubrication Intervals 5 Contamination Prevention Strategies 6 Workplace Safety and Efficiency Gains
More informationELECTRIC MOTOR TEFC OPERATION & MAINTENANCE. meps Approved
SOUTH AUSTRALIA HEAD OFFICE (Accounts / Payments) 34-36 Kinkaid Avenue NORTH PLYMPTON SA 5037 Ph: (08) 8295 5566 Fax: (08) 8295 5533 VICTORIA 23 James Street CLAYTON SOUTH VIC 3169 Ph: (03) 9544 2324 Fax:
More informationIP Rating Chart. 910 East Orangefair Lane Anaheim, CA 92801 USA. www.anaheimautomation.com 714-992-6990 714-992-0471, Fax
IP, NEMA and UL Rating Codes The International Protection Rating, sometimes referred to as an Ingress Protection rating, is a set of codes used to define specific levels of protection. These codes consist
More informationDODGE USAF 200/300 Direct Mount Pillow Block Bearings
DODGE USAF 200/300 Direct Mount Pillow Block Bearings These instructions must be read thoroughly before installation or operation. WARNING: To ensure that drive is not unexpectedly started, turn off and
More informationThe Ultimate Truck Stock Motor
The Ultimate Truck Stock Motor What is a Rescue Motor? Universal Replacement Motor for Condenser Fan and Direct Drive Blower Applications Multi-Horsepower PSC Motors Flexible Mounting Options Permanent
More informationELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION
ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION SC ELECTROPUTERE SA SC ELECTROPUTERE SA 1. Vision, Mission, Values SC ELECTROPUTERE SA 2. LOCATION Craiova: Located in the South West of the country,
More informationSpare parts, installation and maintenance of ac motors
Rotating Electrical Machines Spare parts, installation and maintenance of ac motors 3-E Contents Introduction Pre-installation requirements Warning Receipt Lifting Eyebolt/lifting lug bolt torques Motor
More informationMotor Accessories. C-Face Kits for Field Conversion NEMA AC Motors
C-Face Kits for Field Conversion NEMA AC s Features: Complete kits with all hardware necessary for converting Baldor 56 though 449T frame ridgid base motors to C-Face mounting with base. For Baldor conversion,
More informationO-I DUBI PLANT FANS Quotation Spec Data & Specifications
TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement
More informationLow Profile Unit Cooler
Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost
More informationThe Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,
The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, manufacturing and service needs in the field of submersible pumps. Our engineering
More informationClimasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
More informationSpecifying higher-quality durable power tools
Case study Specifying higher-quality durable power tools June 2011 A case study of three cordless drills to illustrate and encourage specifications for durability and repair, with design principles that
More informationAir blast cooler/radiator DK A03
A03 Air blast cooler/radiator DK Tailor-made cooling for all power-generation processes Luvata: power in good hands For those power-generation processes with the most stringent requirements and often extreme
More informationContents. Spare parts list...16 Electrical wiring...17 Electrical components...18 Miscellaneous / Notes...19. Subject to change without notice DHA 250
3 Contents General safety information...4 Applications...5 Method of operation...5 Product description...6 Casing...6 Rotor...6 Filter...6 Fan for process- and reactivation air...6 Heater for reactivation
More information26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
More informationGenerators TEM. for small hydroelectric power stations. Electric Machines
Generators for small hydroelectric power stations TEM Electric Machines Advanced solutions for the cleanest energy Reputable manufacturer of generators for small hydroelectric power stations TED Electric
More informationManual for High Voltage Process Performance Motors ABB
Manual for High Voltage Process Performance Motors ABB Safety Instructions AMA, AMB, AMG, AMH, AMI, AMK, AMZ, HXR, M3BM, M3GM 1. General 2. Intended use General safety regulations, specific agreements
More informationIEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual
IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual 7/09 MN301 Table of Contents Section 1 General Information.................................................. 1-1 Overview........................................................
More informationRegal Beloit AC Motors
Installation, Operation and Maintenance Instructions for Industrial AC Induction Motors 140-6800 Frames (NEMA) 90 280 Frames (IEC) Regal Beloit AC Motors LEESON ELECTRIC Contact Motor Customer Service
More informationTECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
More informationSurface Technology. Centrifugal Fan GMD
Centrifugal Fan ATEX classed adapted for paint shops Wide assortment broad area of application Service friendly low maintenance costs Headquarters: Centrifugal Fan Centrifugal Fan is a direct driven industrial
More informationSECTION 16461 DRY-TYPE TRANSFORMERS
SECTION 16461 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Furnishing and installation of and testing of cast resin dry type MV/LV distribution transformer in accordance with specifications and drawings. Any
More informationMODEL HSR-007 Direct Drive Rolling Steel
MODEL HSR-007 Direct Drive Rolling Steel 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 Tel: 866-792-9968 or 705-792-9968 Fax: 705-735-9564 www.tnrdoors.com email: info@tnrdoors.com Model HSR-007
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationGE Power Conversion. Generators. 2,500 to 80,000 kva Up to 22,000 Volts
GE Power Conversion Generators 2,500 to 80,000 kva Up to 22,000 Volts 2 GE I Power Conversion GE has been setting the standard in generator manufacturing for over 130 years. GE created and implemented
More informationUPBLAST & HOODED PROPELLER ROOF VENTILATORS
The Industrial Choice. Model D53 / B53 Model HD53 / HB53 UPBLAST & HOODED ELLER ROOF VENTILATORS Direct Drive & Belt Driven Model D53 / B53 Upblast Exhaust Fans Model HD53 / HB53 Hooded Supply & Exhaust
More information(3) Explosion proof. Designed to prevent ignition of any explosive gases or dust and dirt which may surround the motor.
ELECTRIC MOTORS Enclosures for Motors Types of motor enclosures generally used in farm applications: (1) Open type; drip proof or splash-proof. A general purpose motor for use in dry locations which are
More informationAnnex-A TECHNICAL SPECIFICATION
Annex-A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 0.4kV (2,000kVA) DIESEL GENERATOR 1 1.0 SCOPE This specification covers the requirements of design, manufacture, delivery
More information