Smoke Extraction Motors Cast Iron Frame Improved Efficiency EFF2 Standard Features:

Size: px
Start display at page:

Download "Smoke Extraction Motors Cast Iron Frame Improved Efficiency EFF2 Standard Features:"

Transcription

1 Smoke Extraction Motors Cast Iron Improved Efficiency EFF2 Standard Features: Motors Energy Automation Coatings Three-phase, multivoltage, IP55, TEFC : 0.15 up to 330 s: up to 355M/L Voltage: /3-415V (up to ) 3-415/660V (from 112M and up) Class F insulation ( T=K) Continuous duty: S1 Design N Ambient temperature: 40 C, at 1000 m.a.s.l. Squirrel cage /Aluminium die cast Enclosure: TEFC or TEAO Pad mounted model: frame sizes up to 250 (132M/L and 1M are not available) Foot mounted model: frame sizes up to 355 Construction form: B3 (B30 for Pad Mounted Motors) Labyrinth seals (except 200 C/2 hours motors) Krytox (Except 200ºC/2 hours motor) Drain Plug One meter long flying leads for pad mounted motors (without terminal box) Regreasing Nipple for frame: 160 and up (300ºC/1 hour and 400ºC/2 hours) 225 and up (200ºC/2 hours Painting provided with modified Phenolic Resin Color - Aluminium Options available, on request. Typical Applications: These motors are used where a large concentration of people in commercial and industrial facilities is present: Large buildings, Shopping malls, Factories, Warehouses, Enclosed parking lots Other ventilation systems Service Certification F200 F300 F400 S1-40ºC S1-40ºC S1-40ºC S2* - 200ºC - 2 hours S2* - 300ºC - 1 hour S2* - 400ºC - 2 hours BSRIA - U.K. s: 132 to 2 BSRIA - U.K. s: to 250 Also avaiable certification for 300º C/2 hours BSRIA - U.K. s: to 1 CTICM - France s: 90 to 2 Pole: IV, VI, VIII, VI/IV, VII/Vpoles Insulation Class Ins. Class F; Temp. Rise K Ins. Class H; Temp. Rise K or 105K Standard EM Pole / Sizes II, IV/II pole (frame sizes up to 250) available IV, VI, VIII/IV, VI/IV pole ( frame sizes up to 355M/L) Construction TEFC or TEAO (Foot or flange mounted / pad mounted for frame sizes up to 250)

2 Features and Benefits Bearings WEG motors are fitted with the highest quality bearings selected from the best manufacturers in the world and designed to ensure long life of the motor even under heavy operating conditions. For motors supplied with high temperature grease, bearings are designed to meet critical operating conditions. WEG uses Krytox Grease that provides protection from rusting, high-temperature corrosion and antiwear. Krytox allows extended lubrication intervals. Endshield Made of cast iron offering a superior mechanical strength, corrosion-resistance and extended lifetime. WEG motors are made of FC-200 high-grade cast iron (same density as flameproof motors). The frames are provided with fins aiming at improving the heat dissipation and adequately spaced to minimize air blockage due to accumulation of dirt. The assemby system is prepared for direct installation in ventilation ducts. The motors can be mounted in either horizontal or vertical positions. Terminal Box Motor supplied with terminal box base and extended leads (1 meter) allowing lead connection outside of the duct. Loose terminal box and longer power supply leads can also be supplied. Nameplate Stainless steel nameplate ensuring a permanent record of all motor data. Rotor High pressure die cast dynamically balanced, thus reducing vibrations. Stator Built with low magnetic loss steel lamination reducing losses and operating temperature. Drain Hole Provided with plastic drain plug allowing drainage of condensed water. Winding The insulation system of the winding has been specially selected and tested to ensure that it will withstand the extreme temperature during the emergency period. The windings are impregnated with dipping and baking process (frames up to 200L) and continuous resin flow process (frames up to 355M/L). For 300 C/1hour and 400 C/2 hours motors WEG uses special wire and special varnish impregnation. Shaft WEG uses SAE/AISI 1040/45 carbon steel as standard, which provides high mechanical strength, preventing bending under load and minimizes fatigue which extends lifetime. Specially designed to withstand s caused during motor acceleration and deceleration. Upon special design motor, shaft can have second shaft end. Endshields Made of cast iron, they are provided with external fins for better heat dissipation, thus increasing bearing life. Seals WEG motors (300 C/2 hours and 400 C/2 hours) are fitted with Taconite Labyrinth seals to provide a good protection in dusty and high moisture environments. Low Voltage Motors 137

3 Smoke Extraction Motors Cast Iron - Single Speed C/2 hours Improved Efficiency EFF2 / II Pole rpm / / S / L M / S S / / L / M 1) / L / L / / S/M / / S L* / M / M* M / L* / L* IV Pole rpm / / S / L / / M S / M / L / M1) L / L / / S/M / S/M / S/M / / / / M/L / M/L / M/L / M/L / / S L* M* S M/L*2) / L* M1) / M / L / / S/M S/M / S/M / * / Notes: *Class F insulation with T105K Standard voltage, connection and frequency: V 50Hz 3-415V 50Hz 3-415V Y 50Hz V Y 50Hz The values shown are subject to change without prior notice. To obtain guaranteed values please access our website. locked db Efficiency Power Factor (Cos 138 Low Voltage Motors

4 Smoke Extraction Motors Cast Iron - Single Speed C/2 hours Improved Efficiency EFF2 3 V 415 V Efficiency Power Factor (Cos Efficiency Power Factor (Cos II Pole rpm IV Pole rpm ) For Pad Mounted, please consider frame size 1L. 2) size 132M/L is not available for Pad Mounted. For Pad Mounted version frame sizes up to 250S/M. Low Voltage Motors 139

5 Smoke Extraction Motors Cast Iron - Single Speed C/2 hours Improved Efficiency EFF2 / locked Efficiency Power Factor (Cos VI Pole rpm / / S / L / M / S M M / / L / L / L / L / S/M S/M / S/M / M/L / M/L / M/L / M/L / M/L* / M / S S/M S/M * / VIII Pole rpm / / S / L / / / M / S / M / / / L / L L / / / S/M / S/M / S/M / / / M/L / M/L / M/L / M/L / / S/M / S/M / db Notes: *Class F insulation with T105K Standard voltage, connection and frequency: V 50Hz 3-415V 50Hz 3-415V Y 50Hz V Y 50Hz The values shown are subject to change without prior notice. To obtain guaranteed values please access our website. 140 Low Voltage Motors

6 Smoke Extraction Motors Cast Iron - Single Speed C/2 hours Improved Efficiency EFF2 3 V 415 V Efficiency Power Factor (Cos Efficiency Power Factor (Cos VI Pole rpm VIII Pole rpm ) For Pad Mounted, please consider frame size 1L. 2) size 132M/L is not available for Pad Mounted. For Pad Mounted version frame sizes up to 250S/M. Low Voltage Motors 141

7 Smoke Extraction Motors Cast Iron - Two Speed C/2 hours Improved Efficiency EFF2 - Variable IV/II Pole - Dahlander Winding / locked Efficiency Power Factor (Cos 50Hz - 400V - IV/II pole (1500/3000 rpm) - Y / YY connection / / S / L / M / / S / M / / / / L / / M 1) / / L / / L / db Notes: *Class F insulation with T105K Standard voltage, connection and frequency: V 50Hz 3-415V 50Hz 3-415V Y 50Hz V Y 50Hz The values shown are subject to change without prior notice. To obtain guaranteed values please access our website. 1) For Pad Mounted, please consider frame size 1L. 2) size 132M/L is not available for Pad Mounted. For Pad Mounted version frame sizes up to 250S/M. 142 Low Voltage Motors

8 Smoke Extraction Motors Cast Iron - Two Speed C/2 hours Improved Efficiency EFF2 - Variable VIII/VI Pole - Dahlander Winding / locked db Efficiency Power Factor (Cos 50Hz - 400V - VIII/IV pole (750/1500 rpm) - Y / YY connection / / / S / / L / / / M / S / / M/L 2) / / / / L / M 1) L L L* / / / S/M / S/M / / / / Low Voltage Motors 143

9 Smoke Extraction Motors Cast Iron - Two Speed C/2 hours Improved Efficiency EFF2 - Variable VI/IV Pole - Independent Winding / 50Hz - 400V - VI/IV pole (1000/1500 rpm) - Y / Y connection locked Efficiency Power Factor (Cos / / S / L / / / / M / S M / / / L / M 1) M 1) L L / / / S/M / S/M / / / / db Notes: *Class F insulation with T105K Standard voltage, connection and frequency: V 50Hz 3-415V 50Hz 3-415V Y 50Hz V Y 50Hz The values shown are subject to change without prior notice. To obtain guaranteed values please access our website. 144 Low Voltage Motors

10 Smoke Extraction Motors Cast Iron - Two Speed C/2 hours Improved Efficiency EFF2 - Variable IV/II Pole - Dahlander Winding / locked Efficiency Power Factor (Cos 50Hz - 400V - IV/II pole (1500/3000 rpm) - D / YY connection / S / L / / M / S / M / / L* / M 1) / / L / L / S/M / db 1) For Pad Mounted, please consider frame size 1L. 2) size 132M/L is not available for Pad Mounted. For Pad Mounted version frame sizes up to 250S/M. Low Voltage Motors 145

11 Smoke Extraction Motors Cast Iron - Two Speed C/2 hours Improved Efficiency EFF2 - Variable VIII/IV Pole - Dahlander Winding / locked Efficiency Power Factor (Cos 50Hz - 400V - VIII/IV pole (750/1500 rpm) - Δ / YY connection / / S L / / / M / S / / M/L 2) / / / / L / / L / / L / / / / S/M / / S/M / S/M / / / / / db Notes: *Class F insulation with T105K Standard voltage, connection and frequency: V 50Hz 3-415V 50Hz 3-415V Y 50Hz V Y 50Hz The values shown are subject to change without prior notice. To obtain guaranteed values please access our website. 146 Low Voltage Motors

12 Smoke Extraction Motors Cast Iron - Two Speed C/2 hours Improved Efficiency EFF2 - Variable VIII/IV Pole - Dahlander Winding / locked db Efficiency Power Factor (Cos 50Hz - 400V - VI/IV pole (1000/1500 rpm) - Y / Y connection / / / S L / M S M L / M 1) L L / / S/M / S/M / / S/M / / * ) For Pad Mounted, please consider frame size 1L. 2) size 132M/L is not available for Pad Mounted. For Pad Mounted version frame sizes up to 250S/M. Low Voltage Motors 147

13 Smoke Extraction Motors Cast Iron - Single Speed C/1 hour Improved Efficiency EFF2 / locked Efficiency Power Factor (Cos II Pole rpm / / S / L M / S S / / L / M 1) / L / L / / S L* / M / M* M / L* / L* IV Pole rpm / / S / L / / M S / M / L / M1) L / L / / S/M / S/M / S/M / / / / M/L / M/L / M/L / M/L / / S L* M* S / L* L / / S/M S/M / S/M / * / db Notes: *Class F insulation with T105K Standard voltage, connection and frequency: V 50Hz 3-415V 50Hz 3-415V Y 50Hz V Y 50Hz The values shown are subject to change without prior notice. To obtain guaranteed values please access our website. 148 Low Voltage Motors

W50 Three-Phase Electric Motor

W50 Three-Phase Electric Motor Motors Automation Energy Transmission & Distribution Coatings W50 Three-Phase Electric Motor Technical Catalogue IEC Market W50 - The New Generation of WEG Motors for Heavy Duty Applications The W50 motor

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check

More information

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP ABB The Preferred Partner Egypt Cement Corporation, a major cement manufacturer, has chosen ABB wound rotor motors for all key applications

More information

Horizontal Jet Pumps 1/3-1-1/2 HP

Horizontal Jet Pumps 1/3-1-1/2 HP Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The

More information

We will discuss common industrial applications with guides for the proper use of electric motors on these.

We will discuss common industrial applications with guides for the proper use of electric motors on these. INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS AL SERIES

THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS AL SERIES THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS AL SERIES IE2 FRAMES 80 355 0,75 315kW (1500rpm) FOR INVERTER DUTY Code Declaration of conformity The motors described in this catalogue satisfy the essential

More information

A S Y N C H R O N O U S M O T O R S

A S Y N C H R O N O U S M O T O R S ASYNCHRONOUS M O T O R S S E R I E S INDAR ASYNCHRONOUS MOTORS S E R I E S WHO WE ARE Indar Electric s trajectory is endorsed by the construction of thousands of motors for the different industrial sectors.

More information

Catalog. Low voltage Water cooled motors

Catalog. Low voltage Water cooled motors Catalog Low voltage Water cooled motors We provide motors and generators, services and expertise to save energy and improve customers processes over the total lifecycle of our products, and beyond. 2 Low

More information

COOLING TECHNOLOGY INSTITUTE

COOLING TECHNOLOGY INSTITUTE PAPER NO: CATEGORY: TP09-18 FANS COOLING TECHNOLOGY INSTITUTE RECENT DEVELOPMENTS IN MOTOR TECHNOLOGY ALLOW DIRECT DRIVE OF LOW SPEED COOLING TOWER FANS ROBBIE MCELVEEN BILL MARTIN RYAN SMITH BALDOR ELECTRIC

More information

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO) SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY

More information

CE Marking to BS EN 12101-3

CE Marking to BS EN 12101-3 CE Marking to BS EN 12101-3 300ºC/2 Hrs, PWA range Foot mount motors Report Number 54594/3 Edition 2 This report supersedes Report Number 54594/3 dated 14 March 2011 Carried out for Pitsan By Mark Roper

More information

Single-Phase AC Synchronous Generator

Single-Phase AC Synchronous Generator ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description

More information

Raising the waters. Lift irrigation is getting a boost from ABB s synchronous motors

Raising the waters. Lift irrigation is getting a boost from ABB s synchronous motors Raising the waters Lift irrigation is getting a boost from ABB s synchronous motors JARI LINDSTRÖM, TAPIO RAUHALA, MAGNUS REJSTRÖM In India, the scarcity of water is unfortunately a harsh reality. Still,

More information

Permanent Magnet Technology within Direct Drive Cooling Tower Motors Creates System Energy Savings

Permanent Magnet Technology within Direct Drive Cooling Tower Motors Creates System Energy Savings Permanent Magnet Technology within Direct Drive Cooling Tower Motors Creates System Energy Savings Roman Wajda, Robbie McElveen, Bill Martin, and Steve Evon, Baldor Electric Company ABSTRACT At a time

More information

WEg Mod Shop Modification Program, Special Features & Spare Parts

WEg Mod Shop Modification Program, Special Features & Spare Parts INDEX & ACCESSORIES WEg Mod Shop Modification Program, Special Features & Spare Parts V-RING NON-DRIVE ENDSHIELD BEARING STATOR BEARING V-RING FAN COVER FAN FRAME ROTOR DRIVE ENDSHIELD TERMINAL BOX WEg

More information

TABLE OF CONTENTS INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES...

TABLE OF CONTENTS INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES... SYNCHRONOUS MOTORS TABLE OF CONTENTS Motores Síncronos INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES...11 CONSTRUCTIVE CHARACTERISTICS...12

More information

AC Electric Motors best practice

AC Electric Motors best practice If you want to learn more about best practice machinery maintenance, or world class mechanical equipment maintenance and installation practices, follow the link to our Online Store and see the Training

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles AC Induction Motors Simplest and most rugged electric motor Consists of wound stator and rotor assembly AC in the primary member (stator) induces current in the secondary member (rotor) Combined electromagnetic

More information

SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006

SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006 SINGLE PHASE MOTORS INSTALLATION AND MAINTENANCE MANUAL March 21, 2006 Irvine, California (800) 474-0520 Indianapolis, Indiana (800) 866-7973 Hamilton, Ontario (800) 809-0330 e-mail: sales@sterlingelectric.com

More information

Introduction. Upon completion of Basics of AC Motors you should be able to:

Introduction. Upon completion of Basics of AC Motors you should be able to: Table of Contents Introduction...2 AC Motors...4 Force and Motion...6 AC Motor Construction... 12 Magnetism... 17 Electromagnetism... 19 Developing a Rotating Magnetic Field...24 Rotor Rotation...29 Motor

More information

Baldor Electric Company Premium Efficiency Motor Specification Totally Enclosed Fan Cooled Motor 1-250 HP Rev June 6, 2001

Baldor Electric Company Premium Efficiency Motor Specification Totally Enclosed Fan Cooled Motor 1-250 HP Rev June 6, 2001 Table of Contents 1.0 Purpose 2.0 Scope Baldor Electric Company Premium Efficiency Motor Specification Totally Enclosed Fan Cooled Motor 1-250 HP Rev June 6, 2001 3.0 Motor Requirements 3.1 Applicable

More information

Fin-cooled motors for the oil, gas, chemical and petrochemical industries. Loher CHEMSTAR and Loher VARIO motors. Explosion-proof motors LOHER

Fin-cooled motors for the oil, gas, chemical and petrochemical industries. Loher CHEMSTAR and Loher VARIO motors. Explosion-proof motors LOHER Fin-cooled motors for the oil, gas, chemical and petrochemical industries Loher CHEMSTAR and Loher VARIO motors Explosion-proof motors LOHER Danger of explosion, aggressive atmospheres, frequently extreme

More information

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated? Extra Questions - 2 1. A straight length of wire moves through a uniform magnetic field. The e.m.f. produced across the ends of the wire will be maximum if it moves: a) along the lines of magnetic flux

More information

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive

More information

PPA & PPC series motors High specification cast iron units

PPA & PPC series motors High specification cast iron units Edition 4 Issue 3 PPA & PPC series motors High specification cast iron units Accreditation No. 14396 SOLUTIONS, not just products Specialists in Electric Motors, Geared Motors & AC Drives At CMG we offer

More information

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html

More information

CRK 2-130 A-W-A-BUBV 85805906

CRK 2-130 A-W-A-BUBV 85805906 GRUNDFOS DATA BOOKLET CRK 2-13 A-W-A-BUBV 858596 Grundfos Pump 497113 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crk2/497113/crk-2-13-13-a-w-a-auuv.html

More information

Baldor Electric ProSPEC MASTERFORMAT SPECIFICATION May 3, 2005. A. This specification covers integral horsepower squirrel cage AC induction motors.

Baldor Electric ProSPEC MASTERFORMAT SPECIFICATION May 3, 2005. A. This specification covers integral horsepower squirrel cage AC induction motors. SECTION 16221 - TEFC AC INDUCTION MOTORS PART 1 - GENERAL 1.1 SUMMARY A. This specification covers integral horsepower squirrel cage AC induction motors. B. This specification is intended to specify superior

More information

MEMBRANE VACUUM MINI PUMPS

MEMBRANE VACUUM MINI PUMPS MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free

More information

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100 CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL

More information

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages. Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally

More information

Baldor Electric Company Premium Efficiency Motor Specification Open Drip-Proof Motors 1-500 HP Rev June 6, 2001

Baldor Electric Company Premium Efficiency Motor Specification Open Drip-Proof Motors 1-500 HP Rev June 6, 2001 Table of Contents 1.0 Purpose 2.0 Scope Baldor Electric Company Premium Efficiency Motor Specification Open Drip-Proof Motors 1-500 HP Rev June 6, 2001 3.0 Motor Requirements 3.1 Applicable Codes and Regulations

More information

ICQ Series - square centrifugal

ICQ Series - square centrifugal product ICQ Square Centrifugal (TEFC) dimensions mm 280-710 poles & duty 4-8 / up to 4,500 L/s application High performance centrifugal fans for medium to high pressure ducted systems. ICQ Series The ICQ

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions Installation, Operation and Maintenance Instructions for AC Induction Motors 56-6800 Frames (NEMA) 63 280 Frames (IEC) MARATHON ELECTRIC Contact Motor Customer Service at: Phone: (75) 675-33 www.marathonelectric.com

More information

Rotary Phase Converters

Rotary Phase Converters FACTS from Ronk Electrical Industries, Inc. Bulletin 11981 Rotary Phase Converters ROTOVERTER Pat. No. 3,670,238 ROTO-CON Pat. No. 4,158,225 What are the ROTO-CON and ROTOVERTER power converters? The ROTO-CON

More information

Medium voltage Electric motors ELECTRICAL MACHINES UNIBOX & MS4

Medium voltage Electric motors ELECTRICAL MACHINES UNIBOX & MS4 Medium voltage Electric motors ELECTRICAL MACHINES UNIBOX & MS4 Index - Medium Voltage Motor Series PRODUCT TOPIC ACTOM our company history Who is ACTOM PG UNIBOX Bearings and lubrication 7 UNIBOX Ventilation

More information

Multistage high-pressure multistage centrifugal pumps

Multistage high-pressure multistage centrifugal pumps Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,

More information

Standard offering (pumps)

Standard offering (pumps) MDM PUMPS LTD Spring Lane Malvern, Worcs. England. WR14 1BP This outlines what we typically supply. Tel: +44 (0)1684 892678 Fax: +44 (0)1684 892841 E-mail: Website: Standard offering (pumps) info@mdmpumps.co.uk

More information

Product Brochure. Certified Mining Motors

Product Brochure. Certified Mining Motors Product Brochure Certified Mining Motors Profile Baldor Electric Company (a member of the ABB group) is a world leader in motors for the mining industry. In the continuous (24/7) operation of underground

More information

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

General Information. ME-business can be accessed through: www. marathonelectric.com.

General Information. ME-business can be accessed through: www. marathonelectric.com. MARATHON ELECTRIC Since 1913, Marathon Electric s name has been recognized for engineering excellence, custom-designed products and an extensive product line of industrial quality motors. Available in

More information

AC METRIC (IEC) MOTORS THREE PHASE

AC METRIC (IEC) MOTORS THREE PHASE AC METRIC MOTORS These high efficiency motors meet North American performance standards and EPACT energy efficiency mandates, and have.5 service factors. Typically used for replacement on machine tools,

More information

3 Phase AC Induction Motors

3 Phase AC Induction Motors 3 Phase AC Induction Motors INSTALLATION AND OPERATION MANUAL August 21, 2015 Indianapolis, Indiana (00) 66-93 e-mail: sales@sterlingelectric.com www.sterlingelectric.com 93 Allison Avenue, Indianapolis,

More information

GE Power Conversion. Motors. Medium / High Voltage and High Speed 190 to 100,000 kw 250 to 134,000 HP

GE Power Conversion. Motors. Medium / High Voltage and High Speed 190 to 100,000 kw 250 to 134,000 HP GE Power Conversion Motors Medium / High Voltage and High Speed 190 to 100,000 kw 250 to 134,000 HP 2 GE I Power Conversion GE has been setting the standard in manufacturing motors for over 125 years.

More information

Unit 33 Three-Phase Motors

Unit 33 Three-Phase Motors Unit 33 Three-Phase Motors Objectives: Discuss the operation of wound rotor motors. Discuss the operation of selsyn motors. Discuss the operation of synchronous motors. Determine the direction of rotation

More information

Mounting Instructions. Torque Transducer. A0329 3.2 en

Mounting Instructions. Torque Transducer. A0329 3.2 en Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................

More information

BRUSHLESS DC MOTORS. BLDC 22mm. BLDC Gearmotor Size 9. nuvodisc 32BF. BLDC Gearmotor Size 5

BRUSHLESS DC MOTORS. BLDC 22mm. BLDC Gearmotor Size 9. nuvodisc 32BF. BLDC Gearmotor Size 5 BRUSHLESS DC MOTORS BLDC Gearmotor Size 9 BLDC 22mm nuvodisc 32BF BLDC Gearmotor Size 5 Portescap Brushless DC motors are extremely reliable and built to deliver the best performances. Their high power

More information

Why Baldor? Table of Contents. www.baldor.com

Why Baldor? Table of Contents. www.baldor.com Pump Motors Why Baldor? Industry s shortest lead times/flexible manufacturing. Baldor has the industry s shortest lead times on custom motors just ten working days. Our unique LEAN FLEX FLOW manufacturing

More information

How the efficiency of induction motor is measured?

How the efficiency of induction motor is measured? How the efficiency of induction motor is measured? S. Corino E. Romero L.F. Mantilla Department of Electrical Engineering and Energy E.T.S.I.I. y T. Universidad de Cantabria Avda de Los Castros, 395 Santander

More information

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor INSTALLATION, OPERATION AND MAINTENANCE MANUAL For SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor Yeomans Chicago Corporation 3905 Enterprise Court P.O. Box 6620 Aurora, IL 60598-0620 Phone:

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

What Do All Those Things on an AC Motor Nameplate Mean?

What Do All Those Things on an AC Motor Nameplate Mean? What Do All Those Things on an AC Motor Nameplate Mean? Introduction: Ever order a motor on power, speed, and enclosure? PO says maybe "5 hp, 1,800 rpm, TEFC." New-motor nameplate says "HP 5, RPM 1748,

More information

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 APPROVED NO : APPROVED BY : (AUTHORIZED) SPEC.NO D600023 ISSUE DATE 08.06.1998 DAWN.

More information

Permanent Magnetic Generator Construction Manual

Permanent Magnetic Generator Construction Manual Permanent Magnetic Generator Construction Manual http://hojomotor.com Our Team Doing an On-site Assembly in Peru http://hojomotor.com Section 1) Introduction This manual describes how to build a 'permanent

More information

"AC2EC" - Replacement made easy New EC motor design Compact and efficient

AC2EC - Replacement made easy New EC motor design Compact and efficient "AC2EC" - Replacement made easy New EC motor design Compact and efficient The efficiency of the fans used is a central issue in ventilation and airconditioning technology. This is encouraged not only by

More information

Water-cooled three-phase asynchronous motors. Type series K21B / K23B

Water-cooled three-phase asynchronous motors. Type series K21B / K23B Water-cooled three-phase asynchronous motors Type series K21B / K23B Contents Page Introduction 3 Standards and regulations 4 Design version 4 Water cooling 5 Degree of protection 5 Drain holes 5 Vibration

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw ,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted

More information

FOXAIR 60/50 ALL MODELS

FOXAIR 60/50 ALL MODELS FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,

More information

1 Temperature Derating Guide

1 Temperature Derating Guide VLT HVAC Drive FC 02 Application Note Temperature Derating Guide Temperature Derating Guide.. Abstract This paper provides detailed data regarding the operation of the VLT HVAC Drive FC02 at varying ambient

More information

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd ACTOM OUTDOOR DISCONNECTORS Single Side Break (SSB) Disconnector 22-132 kv, 800-1 A, 25 ka - 3s Typical bearing assembly. Voltage range 11 kv to 132

More information

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation IOSR Journal of Engineering (IOSRJEN) ISSN (e): 2250-3021, ISSN (p): 2278-8719 Vol. 04, Issue 01 (January. 2014), V6 PP 01-12 www.iosrjen.org Paper on Basbar Trunking System for Electrical Supply to Industrial

More information

Turbo generators Best quality for thermal power plants

Turbo generators Best quality for thermal power plants Turbo generators Best quality for thermal power plants www.andritz.com ANDRITZ HYDRO Turbo generators International technology Group ANDRITZ is a globally leading supplier of plants, equipment, and services

More information

MICRO HYDRO POWER GENERATING EQUIPMENT

MICRO HYDRO POWER GENERATING EQUIPMENT MICRO HYDRO POWER GENERATING EQUIPMENT TOSHIBA TOSHIBA ENGINEERING In general, specifications of hydroelectric power system vary depending upon the installation location. The hydro turbine and generator

More information

Low Voltage Transformers Sealed, General Purpose, Dry Type

Low Voltage Transformers Sealed, General Purpose, Dry Type Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................

More information

A technical guide to Shell tactic emv

A technical guide to Shell tactic emv A technical guide to Shell Tactic EMV TABLE OF CONTENTS SECTION PAGES Introduction 3 Benefits of Short Re-Lubrication Intervals 5 Contamination Prevention Strategies 6 Workplace Safety and Efficiency Gains

More information

ELECTRIC MOTOR TEFC OPERATION & MAINTENANCE. meps Approved

ELECTRIC MOTOR TEFC OPERATION & MAINTENANCE. meps Approved SOUTH AUSTRALIA HEAD OFFICE (Accounts / Payments) 34-36 Kinkaid Avenue NORTH PLYMPTON SA 5037 Ph: (08) 8295 5566 Fax: (08) 8295 5533 VICTORIA 23 James Street CLAYTON SOUTH VIC 3169 Ph: (03) 9544 2324 Fax:

More information

IP Rating Chart. 910 East Orangefair Lane Anaheim, CA 92801 USA. www.anaheimautomation.com 714-992-6990 714-992-0471, Fax

IP Rating Chart. 910 East Orangefair Lane Anaheim, CA 92801 USA. www.anaheimautomation.com 714-992-6990 714-992-0471, Fax IP, NEMA and UL Rating Codes The International Protection Rating, sometimes referred to as an Ingress Protection rating, is a set of codes used to define specific levels of protection. These codes consist

More information

DODGE USAF 200/300 Direct Mount Pillow Block Bearings

DODGE USAF 200/300 Direct Mount Pillow Block Bearings DODGE USAF 200/300 Direct Mount Pillow Block Bearings These instructions must be read thoroughly before installation or operation. WARNING: To ensure that drive is not unexpectedly started, turn off and

More information

The Ultimate Truck Stock Motor

The Ultimate Truck Stock Motor The Ultimate Truck Stock Motor What is a Rescue Motor? Universal Replacement Motor for Condenser Fan and Direct Drive Blower Applications Multi-Horsepower PSC Motors Flexible Mounting Options Permanent

More information

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION SC ELECTROPUTERE SA SC ELECTROPUTERE SA 1. Vision, Mission, Values SC ELECTROPUTERE SA 2. LOCATION Craiova: Located in the South West of the country,

More information

Spare parts, installation and maintenance of ac motors

Spare parts, installation and maintenance of ac motors Rotating Electrical Machines Spare parts, installation and maintenance of ac motors 3-E Contents Introduction Pre-installation requirements Warning Receipt Lifting Eyebolt/lifting lug bolt torques Motor

More information

Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors

Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors C-Face Kits for Field Conversion NEMA AC s Features: Complete kits with all hardware necessary for converting Baldor 56 though 449T frame ridgid base motors to C-Face mounting with base. For Baldor conversion,

More information

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

O-I DUBI PLANT FANS Quotation Spec Data & Specifications TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement

More information

Low Profile Unit Cooler

Low Profile Unit Cooler Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost

More information

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, manufacturing and service needs in the field of submersible pumps. Our engineering

More information

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal

More information

Specifying higher-quality durable power tools

Specifying higher-quality durable power tools Case study Specifying higher-quality durable power tools June 2011 A case study of three cordless drills to illustrate and encourage specifications for durability and repair, with design principles that

More information

Air blast cooler/radiator DK A03

Air blast cooler/radiator DK A03 A03 Air blast cooler/radiator DK Tailor-made cooling for all power-generation processes Luvata: power in good hands For those power-generation processes with the most stringent requirements and often extreme

More information

Contents. Spare parts list...16 Electrical wiring...17 Electrical components...18 Miscellaneous / Notes...19. Subject to change without notice DHA 250

Contents. Spare parts list...16 Electrical wiring...17 Electrical components...18 Miscellaneous / Notes...19. Subject to change without notice DHA 250 3 Contents General safety information...4 Applications...5 Method of operation...5 Product description...6 Casing...6 Rotor...6 Filter...6 Fan for process- and reactivation air...6 Heater for reactivation

More information

26 3213.13 Diesel Engine Driven Generators Page 1 of 6

26 3213.13 Diesel Engine Driven Generators Page 1 of 6 Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at

More information

Generators TEM. for small hydroelectric power stations. Electric Machines

Generators TEM. for small hydroelectric power stations. Electric Machines Generators for small hydroelectric power stations TEM Electric Machines Advanced solutions for the cleanest energy Reputable manufacturer of generators for small hydroelectric power stations TED Electric

More information

Manual for High Voltage Process Performance Motors ABB

Manual for High Voltage Process Performance Motors ABB Manual for High Voltage Process Performance Motors ABB Safety Instructions AMA, AMB, AMG, AMH, AMI, AMK, AMZ, HXR, M3BM, M3GM 1. General 2. Intended use General safety regulations, specific agreements

More information

IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual

IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual 7/09 MN301 Table of Contents Section 1 General Information.................................................. 1-1 Overview........................................................

More information

Regal Beloit AC Motors

Regal Beloit AC Motors Installation, Operation and Maintenance Instructions for Industrial AC Induction Motors 140-6800 Frames (NEMA) 90 280 Frames (IEC) Regal Beloit AC Motors LEESON ELECTRIC Contact Motor Customer Service

More information

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:

More information

Surface Technology. Centrifugal Fan GMD

Surface Technology. Centrifugal Fan GMD Centrifugal Fan ATEX classed adapted for paint shops Wide assortment broad area of application Service friendly low maintenance costs Headquarters: Centrifugal Fan Centrifugal Fan is a direct driven industrial

More information

SECTION 16461 DRY-TYPE TRANSFORMERS

SECTION 16461 DRY-TYPE TRANSFORMERS SECTION 16461 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Furnishing and installation of and testing of cast resin dry type MV/LV distribution transformer in accordance with specifications and drawings. Any

More information

MODEL HSR-007 Direct Drive Rolling Steel

MODEL HSR-007 Direct Drive Rolling Steel MODEL HSR-007 Direct Drive Rolling Steel 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 Tel: 866-792-9968 or 705-792-9968 Fax: 705-735-9564 www.tnrdoors.com email: info@tnrdoors.com Model HSR-007

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

GE Power Conversion. Generators. 2,500 to 80,000 kva Up to 22,000 Volts

GE Power Conversion. Generators. 2,500 to 80,000 kva Up to 22,000 Volts GE Power Conversion Generators 2,500 to 80,000 kva Up to 22,000 Volts 2 GE I Power Conversion GE has been setting the standard in generator manufacturing for over 130 years. GE created and implemented

More information

UPBLAST & HOODED PROPELLER ROOF VENTILATORS

UPBLAST & HOODED PROPELLER ROOF VENTILATORS The Industrial Choice. Model D53 / B53 Model HD53 / HB53 UPBLAST & HOODED ELLER ROOF VENTILATORS Direct Drive & Belt Driven Model D53 / B53 Upblast Exhaust Fans Model HD53 / HB53 Hooded Supply & Exhaust

More information

(3) Explosion proof. Designed to prevent ignition of any explosive gases or dust and dirt which may surround the motor.

(3) Explosion proof. Designed to prevent ignition of any explosive gases or dust and dirt which may surround the motor. ELECTRIC MOTORS Enclosures for Motors Types of motor enclosures generally used in farm applications: (1) Open type; drip proof or splash-proof. A general purpose motor for use in dry locations which are

More information

Annex-A TECHNICAL SPECIFICATION

Annex-A TECHNICAL SPECIFICATION Annex-A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 0.4kV (2,000kVA) DIESEL GENERATOR 1 1.0 SCOPE This specification covers the requirements of design, manufacture, delivery