1 The room thermostat application module is placed on a flush-mounted bus coupler. The room thermostat is used for regulating the temperature in individual rooms.the required set temperature can be assigned parameters using the ETS software. In addition the user can adjust the set temperature using a rotary switch and can toggle between comfort and standby mode using an integrated presence switch. The current mode of operation (comfort mode, standby mode, night operation) is displayed by three green LEDs. The frost or heat protection is shown by a red LED while a yellow LED displays the frost alarm. In addition a cover frame in the chosen colour and a flush-mounted bus coupler are required. Note: the position of the PCI is rotated by about 90. Therefore you have to rotate the bus coupling units by about 90. Technical data Power supply EIB 24 VDC, via the bus line Operating and display elements Rotary switch To adjust the set temperature Push button To toggle between comfort/standby Three green LEDs Comfort, standby, night operation Yellow LED Frost alarm Red LED Frost/heat protection Connections Flush-mounted bus coupler 10-pole plug connector Type of protection IP 20, EN mounted on the bus coupler Ambient temperature range Operation - 5 C 45 C Storage -25 C 55 C Transport -25 C 70 C Design alpha nea Colour platinum, bronze, studio white, matt, studio white, gloss, basalt black, cardinal red, hansa blue Mounting latched onto the flush-mounted bus coupler Dimensions 56 x 71 x 17 mm (H x W x D) Weight 0.04 kg Certification CE norm EIB-certified in accordance with the EMC guideline and the low voltage guideline 2-82 July 2000

2 Application programs Number of Max. number of Max. number of communication objects group addresses associations Continuous/Switch Heat Cool / Circuit diagram Bus cable 4 Application module 2 Bus terminal 5 10-pole plug 3 Flush-mounted bus coupler July

3 Continuous/Switch Heat Cool /2 Selection in ETS2 ABB Heating Thermostat The application program makes it possible to have individual room temperature control. The room thermostat can be adapted to various heating and/or cooling appliances by selecting appropriate parameter settings. The thermostat has five operating modes which are each assigned a separate setpoint value in heating/cooling mode. The states are displayed by LEDs on the device. The status of the communication objects Comfort mode, Night operation, Frost/heat protection, Dewpoint mode and Push button determines the active operating mode. It is possible to switch to comfort mode using the presence switch located on the device. The presence switch can also be addressed via the bus and the 1 bit object Push button is available for this purpose. It can also simultaneously send the status of the push buttons to the bus. Caution: If the Push button object and the presence switch are operated at the same time (within approx. 2 s), the push button changes the object value that has just been received. Continuous / Switch Using the parameter Type of heat function or Type of cooling function, it it possible to adapt the internal calculation and output of the control values to the properties of the room and the possible heating or cooling appliances. The parameter has four options: continuous PI control: The control value is determined internally according to a PI algorithm and output via a 1 byte communication object. It is therefore possible for example for electromotive control valves to be addressed in a range between 0 (= 0% = valve closed) and 255 (= 100% = valve fully opened). PWM control: The control value is determined internally according to a PI algorithm and output via a 1 byte communication object. It is therefore possible for example to address electrothermal control valves via switch actuators. The room thermostat operates with pulse width modulation so that the heat output can be set to intermediate values. It is therefore necessary to parameterise the period for the switching cycle of the control values. With a preset cyclic time of 15 minutes (90 * 10 seconds), a control value of 33.3% which has been determined internally means that the valve is opened for 5 minutes and closed for 10 minutes. switching two-step control: The control value is determined internally according to a two-step algorithm with an adjustable hysteresis and output via a 1 bit communication object. It is therefore possible for example for electrothermal control valves to be addressed via switch actuators. The heating valve is closed if the setpoint value is exceeded. If the room thermostat falls below the setpoint value minus the hysteresis, the heating valve is opened. continuous two-step control: The control value is determined internally according to a two-step algorithm with an adjustable hysteresis and output via a 1 byte communication object. It is therefore possible for example to address electromotive control valves. In this case, the room thermostat only sends the values 0 (= 0% = valve closed) and 255 (= 100% = valve fully opened). Heat Cool With the parameter Activation of heat/ cool function, it is determined whether the room thermostat controls heating and/or cooling appliances. There are five different settings available: heat, cool, heat and cool, 2-step heat and 2-step cool. The settings 2-step heat and 2-step cool are used if a relatively slow basic system is to be combined with a faster additional system. An example of this is floor heating as a basic system and warm water heating as an additional system. If there is a substantial system deviation, the additional system helps to correct this deviation as quickly as possible. In the event of a minor system deviation, only the basic system is used July 2000

4 There are various predefined appliances available for selection for the heat function (e.g. warm water heating, floor heating, air convector, electric heating). These settings normally suffice. Should these appliances however not be sufficient for adapting the control system to the heating system, it is also possible to carry out this adjustment via the control parameter. Only in special cases should detailed control parameters be selected after an exact investigation of the controlled variables in the room. The parameters Proportional range for heating and Readjust time for heating should be set individually. The control system can be deactivated for the investigation of these controlled variables. There are also predefined appliances available for the cooling function (e.g. cooling ceiling, air convector, SplitUnit). In special cases, it is also possible to adapt the control system via the control parameters. The room thermostat has parameterisable setpoint values. The base setpoint is preset to 21 C but can be changed if required (7 40 C). The parameters Standby mode, Night operation and Frost/heat protection for the various operating modes can then be set in relation to the base setpoint. In the heat and cool operating mode, the room thermostat uses the parameter Insensitive zone between heat and cool. This prevents the thermostat from switching between heat and cool too frequently. In the settings 2-step heat or 2-step cool, the parameter Distance from basic to additional system is used to prevent the thermostat from toggling. Object no. 3 has the highest priority. The thermostat is always inactive if the value of the object is logic 1. If communication objects no. 0 to 3 have the value 0, the thermostat operates in standby mode. If both object no. 0 Comfort mode and object no. 1 Night operation have the value 1, the comfort mode takes priority. It is possible to adjust the influence of the potentiometer that is attached to the thermostat using the parameter Scaling of setpoint adjustment button. The available settings lie in a range between +/- 0K (= disabled) and +/- 10K. If required, the setpoint can also be set as a 2 byte value using object no. 10. The value is stored in the EEPROM of the bus coupler. Frequent changes (more than 1-2 times a day) are not recommended as the EEPROM memory only permits a certain number of modifications. From standby mode or night operation, it is possible to switch to comfort mode using the presence switch for the set extended comfort period. Once this period has elapsed, the device returns to the original operation mode. It is also possible to deactivate the presence switch to prevent unauthorised persons from operating it. This is a good idea for example in public buildings and schools. If the operation mode has been changed to standby mode, it is a good idea to predefine the behaviour of the presence switch. For this reason, the room thermostat has the parameters Function of push button status if. It is possible to set here whether the push button status should be deleted or recreated (night object is set to 0) or unchanged (comfort object is set to 0). If object no. 3 has the value 0 and object no. 2 has the value 1, the thermostat is always set to the Frost/heat protection operating mode. It is a good idea for the frost/heat protection object to be influenced by a window contact (via a binary input). As soon as the window is opened, the room temperature is lowered for example to 7 C (for heating).. July

5 In addition to controlling heating or cooling appliances, the room thermostat can also output the current temperature. There is a 2 byte communication object available for this. In order for the room temperature to be output automatically, it is necessary to indicate the temperature change which should trigger the sending of a new temperature value. The selected value should not be too low to ensure that the bus load remains negligible. Any measurement errors that may occur e.g. due to the bus coupler heating up can be corrected using an adjustment value. The output of the control value is carried out if it has changed by a specific percentage value. In addition, it can also be necessary for certain actuators to send the control value cyclically. The cyclic time that is to be set depends on the monitoring period of the actuator. It can also be necessary for certain heating or cooling appliances to invert the output of the control value using the parameters Output of control value. Object no. 9 represents the internal control status of the room thermostat. In the basic setting, it is a 1 byte object and displays the following states bit by bit: bit 0: Comfort bit 1: Standby bit 2: Night bit 3: Frost/heat protection bit 4: Dewpoint bit 5: Heat/cool bit 6: Controller OFF bit 7: Frost alarm If required, it is possible to select one of the states using the parameter Meaning of object status. In this case, object no. 9 is a 1 bit object. Recommended settings Heating systems Control valve Control Cyclic time Hysteresis Warm water heating Electrothermal PWM 15 min. None Inlet temperature 40 C to 70 C Warm water heating Electrothermal Two-step None 1 K Inlet temperature < 40 C PWM 15 min. None Floor heating Electrothermal PWM min. None Air convector Electrothermal Two-step None 1 K Electric heating Electrothermal PWM min. None Two-step None 1 2 K Air conditioning Control valve Control Cyclic time Hysterese systems Air convector Continuous Continuous None None Cooling ceiling Electrothermal PWM min. None Two-step None 1 K Electric cooler Electrothermal Two-step None 1 2 K 2-86 July 2000

6 for continuous control value heat 0 1 bit Operation mode Comfort mode 1 1 bit Operation mode Night operation 2 1 bit Operation mode Frost/heat protection 3 1 bit Operation mode Dewpoint mode 4 1 bit Operation mode Push button 5 2 byte Display Current setpoint 6 2 byte Display Room temperature 7 1 byte Control value Heat 8 1 bit Signal Installation is heating 9 1 byte Status Control status 10 2 byte Parameter Base setpoint for continuous control value cool 7 1 bit Signal Installation is cooling 8 1 byte Control value Cool for continuous control value heat and cool 7 1 byte Control value Heat 8 1 byte Control value Cool for switching control value heat and cool 7 1 bit Control value Heat 8 1 bit Control value Cool for switching control value heat 7 1 bit Control value Heat 8 1 bit Signal Installation is heating for switching control value cool 7 1 bit Signal Installation is cooling 8 1 bit Control value Cool July

7 for continuous 2-step heat 7 1 byte Control value Basic heating 8 1 byte Control value Additional heating for switching 2-step heat 7 1 bit Control value Basic heating 8 1 bit Control value Additional heating for continuous 2-step cool 7 1 byte Control value Basic cooling 8 1 byte Control value Additional cooling for switching 2-step cool 7 1 bit Control value Basic cooling 8 1 bit Control value Additional cooling for individual output of control status 9 1 bit Status Control status 2-88 July 2000

8 Parameters The default setting for the values is printed in bold type. The complete parameter list is only displayed in the High Access setting. Configuration of heating/cooling system: Activation of heat / cool function heat cool heat and cool 2-step heat 2-step cool For heat or heat and cool : Type of heat function continuous PI control PWM control continuous two-step control switching two-step control Only for PI or PWM control: Adaptation of PI control to the warm water heating (5K / 150min) heating system For adaptation via control parameter: Proportional range for heating 40 in 0.1 K [10255] Readjust time for heating 120 in 1 min [0255] (0: inactive) Only for two-step control: Hysteresis of the two-step heat 10 controller in 0.1 K (0255) floor heating (5K / 240min) electric heating (4K / 100min) air convector (4K / 90min) SplitUnit (4K / 90min) via control parameter For cool or heat and cool : Type of cooling function continuous PI control PWM control continuous two-step control switching two-step control Only for PI or PWM control: Adaptation of PI control to the cooling ceiling ( 5K / 240min) cooling system For adaptation via control parameter: Proportional range for cooling 40 in 0.1 K [10255] Readjust time for cooling 120 in 1 min [0255] (0: inactive) Only for two-step control: Hysteresis of the two-step cooling 10 controller in 0.1 K (0255) air convector (4K / 90min) SplitUnit (4K / 90min) via control parameter For 2-step heat : Type of basic system continuous PI control PWM control continuous two-step control switching two-step control Only for PI or PWM control: Adaptation of PI control to the basic warm water heating (5K / 150min) heating system For adaptation via control parameter: Proportional range for additional 40 system in 0.1 K [10255] Readjust time for additional system 120 in 1 min [0255] (0: inactive) floor heating (5K / 240min) electric heating (4K / 100min) air convector (4K / 90min) SplitUnit (4K / 90min) via control parameter July

9 Only for two-step control: Hysteresis of the two-step controller 10 of the basic heating in 0.1 K (0255) Type of additional system continuous PI control switching PI control continuous two-step control switching two-step control Only for PI control: Adaptation of PI control to the warm water heating (5K) additional heating system For adaptation via control parameter: Proportional range for additional 40 system in 0.1 K [10255] Only for two-step control: Hysteresis of the two-step controller of 5 the add. heating in 0.1 K (0255) floor heating (5K) electric heating (4K) air convector (4K) SplitUnit (4K) via control parameter For 2-step cool : Type of basic system continuous PI control PWM control continuous two-step control switching two-step control Only for PI or PWM control: Adaptation of PI control to the cooling ceiling (5K / 240min) basic cooling system air convector (4K / 90min) SplitUnit (4K / 90min) via control parameter For adjustment via control parameter: Proportional range for basic system 40 in 0.1 K [10255] Readjust time for basic system 120 in 1 min [0255] (0: inactive) Only for two-step control: Hysteresis of the two-step controller of 10 the basic cooling in 0.1 K (0255) Type of additional system continuous PI control switching PI control continuous two-step control switching two-step control Only for PI control: Adaptation of PI control to the cooling ceiling (5K) additional cooling system For adaptation via control parameter: Proportional range for additional 40 system in 0.1 K [10255] Only for two-step control: Hysteresis of the two-step controller of 5 the add. cooling in 0.1 K (0255) air convector (4K) SplitUnit (4K) via control parameter 2-90 July 2000

10 Setpoints: Base setpoint 21 in 1 C (7 40) Scaling of setpoint adjustment button 3 in 1 K (010) For heat and cool : Reduced heating in standby mode 20 Reduced heating during the night 40 Setpoint for frost protection 7 in 1 C (7 40) Increased cooling in standby mode 20 Increased cooling during the night 40 Setpoint for heat protection 35 in 1 C (7 45) Insensitive range between heat and 20 cool in 0.1 K (0 255) For 2-step heat : Reduced heating in standby mode 20 Reduced heating during the night 40 Setpoint for frost protection 7 in 1 C (7 40) Distance from basic to additional 20 system in 0.1 K (0255) For 2-step cool : Increased cooling in standby mode 20 Increased cooling during the night 40 Setpoint for heat protection 35 in 1 C (7 45) Distance from basic to additional 20 system in 0.1 K (0255) July

11 Configuration of functionality: Only for heat and cool : Assignment of control values to the separate objects heat and cool jointly to object heat Only for separate control values: Toggle between heat and cool automatic with object heat/cool Only for 2-step heat or 2-step cool : Selection between functions/objects blockable additional step external push button - access Meaning of object status control status (EIS6) comfort mode (EIS1) standby mode (EIS1) night mode (EIS1) frost/heat protection (EIS1) dewpoint mode (EIS1) heating (EIS1) control inactive (EIS1) frost alarm (EIS1) Reaction to push button action normal (vandal mode) push button without function Function of push button status if delete status of push buttons night object => 0 recreate status of push buttons Function of push button status if do not change status of push buttons comfort object => 0 delete status of push buttons Duration of the ext. comfort operation in 60 1 min [0255] (0: infinite) Control active inactive Measurement of room temperature: Adjustment of setpoint/actual 5 temperature for autom. sending in 0.1 K (0: inactive) Direction of adjustment of room increase measurement value temperature measurement decrease measurement value Adjustable value of room temperature 0 measurement in 0.1 K [0 127] Control value output: Only for heat : Output of control value heat normal inverted Only for cool : Output of control value cool normal inverted Only for heat and cool : Output of control value heat normal inverted Output of control value cool normal inverted Only for 2-step heat or 2-step cool : Output of control value for base level normal inverted Output of control value for additional normal level inverted 2-92 July 2000

12 Ädjustment for automatic sending 5 in 1% [0100] (0: inactive) ONLY FOR CONTINUOUS! Cyclic time of the switching control 90 value in 10 sec. [1255] ONLY FOR PWM! Cyclic time for automatic sending inactive / 2 min / 10 min / 40 min Filter control value output do not filter only 1 telegram per minute July

ABB i-bus KNX Fan Coil Controller FC/S 1.1

ABB i-bus KNX Fan Coil Controller FC/S 1.1 Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation

More information

ABB i-bus EIB Logic Module LM/S 1.1

ABB i-bus EIB Logic Module LM/S 1.1 Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx 756627xx, 756637xx, 756657xx Documentation Product name: Push button 2-, 3-, 5- gang RTR + display Design: UP (flush-mounting type) ETS search path: Push button / Push button xgang / Push button xgang

More information

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Busch-Watchdog Presence EIB Type: 6131-74-102-500

Busch-Watchdog Presence EIB Type: 6131-74-102-500 Type: 6131-74-102-500 Contents Technical data 2-2 Application programs (List) 2-3 Circuit diagrams 2-3 in combination with Bus coupler FM (6120-102): Switch Value Cyclic Monitoring /3 2-4 Switch Value

More information

How To Use A Power Supply On A Powerline 2.2 (Ai)

How To Use A Power Supply On A Powerline 2.2 (Ai) KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang

More information

Unica for KNX system 226

Unica for KNX system 226 Unica for KNX system 6 P117504 Greater flexibility and comfort, better energy efficiency with KNX More and more electronic appliances are needed for modern comfortable homes that contain everything from

More information

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2 Product Manual ABB i-bus EIB US/U 4.2 US/U 2.2 Intelligent Installation Systems Intelligent and limitless Contents Page 1 General............................................. 3 1.1 Product and functional

More information

Inwall Room Temperature Unit

Inwall Room Temperature Unit Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall

More information

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1 Product Manual ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1 Intelligent Installation Systems This manual describes the function of the Switch

More information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850

More information

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB , GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well

More information

Light scene push button 8gang comfort flush-mounted 751688xx

Light scene push button 8gang comfort flush-mounted 751688xx 751688xx Documentation Product name: Light scene push button 8gang comfort Design: flush-mounting type (Up) ETS search path: Push button / Push button general / Light scene push button 8gang comfort Functional

More information

Product and Application Description

Product and Application Description Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design

More information

ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1

ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................

More information

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Product Manual ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Intelligent Installation Systems This manual describes the function of the EIB monitoring module EUB/S 1.1 with the Application program

More information

Application Unit, MDRC AB/S 1.1, GH Q631 0030 R0111

Application Unit, MDRC AB/S 1.1, GH Q631 0030 R0111 , GH Q631 0030 R0111 SK 0010 B 98 The application unit is a DIN rail mounted device for insertion in the distribution board. The connection to the EIB is established via a bus connecting terminal at the

More information

Inwall 4 Input / 4 Output Module

Inwall 4 Input / 4 Output Module Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...

More information

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion

More information

Push button 3gang standard flush-mounted 751633xx

Push button 3gang standard flush-mounted 751633xx Documentation Product name: Push button 3gang standard Design: device (up) ETS search path: Push button / Push button 3gang / Push button 3gang standard Functional description: The push button 3gang standard

More information

ABB i-bus KNX Application manual Heating/Ventilation/Air Conditioning

ABB i-bus KNX Application manual Heating/Ventilation/Air Conditioning ABB i-bus KNX Application manual Heating/Ventilation/Air Conditioning Description of the symbols: Sample Note Tip Disadvantage Advantage Important Table of content Preface/General... 3 1. Introduction

More information

Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T

Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T HMG 6 T 4930240 HME 6 T 4930245 HM 12 T 4940245 Updated: Dec-14 (subject to change) Page 1 of 61 Contents 1 Contents 2 FUNCTIONAL

More information

Glass sensor 2gang with room thermostat Glass sensor 3gang with room thermostat

Glass sensor 2gang with room thermostat Glass sensor 3gang with room thermostat KNX/EIB Product documentation Glass sensor 2gang with room thermostat Glass sensor 3gang with room thermostat Issue: 16.01.2009 65750120 Page 1 of 240 KNX/EIB Product documentation Content 1 Product definition...

More information

Shutter Actuator, 8-fold, 230 V AC, MDRC JA/S 8.230.1, GH Q631 0063 R0111. ABB i-bus EIB / KNX

Shutter Actuator, 8-fold, 230 V AC, MDRC JA/S 8.230.1, GH Q631 0063 R0111. ABB i-bus EIB / KNX , GH Q631 0063 R0111 2CDC 071 238 F0003 For controlling a maximum of eight independent 230 V AC shutter or sunblind drives via ABB i-bus including the functions Up/Down, Step/Stop, Move to position, Sun

More information

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB Product Manual ABB i-bus KNX Data Logging Unit BDB/S 1.1 Intelligent Installation Systems ABB This manual describes the function of the Data Logging Unit BDB/S 1.1. Subject to changes and errors excepted.

More information

Instruction Manual Service Program ULTRA-PROG-IR

Instruction Manual Service Program ULTRA-PROG-IR Instruction Manual Service Program ULTRA-PROG-IR Parameterizing Software for Ultrasonic Sensors with Infrared Interface Contents 1 Installation of the Software ULTRA-PROG-IR... 4 1.1 System Requirements...

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

ELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB. www.elabo-ts.com

ELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB. www.elabo-ts.com Aus- und Weiterbildung GmbH Home and Building Control KNX / EIB www.elabo-ts.com Design and commissioning of KNX/EIB systems www.elabo-ts.com Hardware page 2-5 Software page 6-9 Projects page 10-15 LOGO!

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

IntesisBox KNX Mitsubishi Heavy Industries AC

IntesisBox KNX Mitsubishi Heavy Industries AC IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)

More information

B/S/H/ Error codes and service programmes PH

B/S/H/ Error codes and service programmes PH 1 ERROR CODES AND APPLIANCE MESSAGES... 3 1.1 Complete overview of all error codes (in order)... 3 Automatic switch-off... 3 Display is dark and any individual LEDs are lit... 3 E 005... 3 E 011... 3 E

More information

IntesisBox KNX Modbus RTU master

IntesisBox KNX Modbus RTU master IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control

More information

Time functions. Functions of the relay. instabus EIB Application program description. September 2001. 12 A1 Binary 510D01

Time functions. Functions of the relay. instabus EIB Application program description. September 2001. 12 A1 Binary 510D01 September 2 2 A Binary 5D Product family: Product type: Manufacturer: Output Binary output, -fold Siemens Name: Load switch UP 5 Order no.: 5WG 5-2AB Functional description Using the application program

More information

Movement/monitoring 1307/1.0 (6325xx)

Movement/monitoring 1307/1.0 (6325xx) /monitoring 1307/1.0 (6325xx) General In the following the device will be referred to as the movement detector. The movement block will only switch off when there is no more movement in front of the device

More information

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting Adding Pneumatic Preset Counter Type 497 Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting VARIABLE PILOT SIGNAL Using two pneumatic preset counters

More information

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485. IntesisBox KNX SAMSUNG Air Conditioning Gateway for integration of Samsung air conditioners into KNX control systems. Integrate Samsung Air Conditioners into KNX. KNX EIB Bus IntesisBox RS485 MIM-B13x/B04A

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

HYDRUS ULTRASONIC METER

HYDRUS ULTRASONIC METER HYDRUS APPLICATION HYDRUS is a static water meter based on the ultrasonic technology. This technology enables accurate calculation of water consumption and eliminates measuring deviations caused by sand,

More information

IntesisBox KNX LG Air Conditioning

IntesisBox KNX LG Air Conditioning IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184 EN KNX TH65-AP Thermo-Hygrometer Technical specifications and installation instructions Item number 70184 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49

More information

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S 2.300.2. Intelligent Installation Systems ABB

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S 2.300.2. Intelligent Installation Systems ABB Product Manual ABB i-bus KNX Universal Dim Actuator, MDRC UD/S 2.300.2 Intelligent Installation Systems ABB UD/S 2.300.2 Universal Dim Actuator, MDRC This manual describes the function of the Universal

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 tecnico@ingeniumsl.com

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 tecnico@ingeniumsl.com Integrations LGAC-KNX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 ingeniumsl@ingeniumsl.com www.ingeniumsl.com

More information

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting

More information

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1 Product manual ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1 Intelligent Installation Systems This manual describes the function of the DALI-Gateway DG/S 8.1 with the application program Dim Slave Lightscenes

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

IntesisBox KNX Modbus TCP master

IntesisBox KNX Modbus TCP master IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration

More information

ABB i-bus EIB Application unit AB/S 1.1 with application program Times Groups/1

ABB i-bus EIB Application unit AB/S 1.1 with application program Times Groups/1 Product manual ABB i-bus EIB with application program Times Groups/1 Intelligent Installation Systems Contents Page 1 Introduction 5 1.1 Product and functional description..................... 5 1.2 Brief

More information

Tebis application software

Tebis application software Tebis application software Input products / ON / OFF output / RF dimmer Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices WYC81xQ

More information

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB Product Manual ABB i-bus KNX IP Interface IPS/S 2.1 Intelligent Installation Systems ABB This manual describes the function of the IP Interface IPS/S 2.1 with the application program IP Interface. Subject

More information

RF 1. Contents: Connecting diagram. Detailed information:

RF 1. Contents: Connecting diagram. Detailed information: Contents: Introduction UFH-ZONE-R UFH-EXTRAZONE -R Connection of a thermostat (UFH-THERM-R) o Joining of a thermostat with UFH-ZONE-R or UFH-EXTRAZONE-R Connection of a digital thermostat (UFH-THERM -RD)

More information

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner Quick Stepper 3G ECP Positioner Versions Mechanical feed-back Pneumatic Remote feed-back Local display, Pneumatic Remote feed-back Local display, Electric / Hydraulic Remote feed-back Electric / Hydraulic

More information

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

ELECTRIC CENTRAL HEATING FLOW BOILER

ELECTRIC CENTRAL HEATING FLOW BOILER ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment

More information

ABB i-bus KNX DALI-Gateway DG/S 8.1

ABB i-bus KNX DALI-Gateway DG/S 8.1 Product manual ABB i-bus KNX DALI-Gateway DG/S 8.1 Intelligent Installation Systems This manual describes the function of the DALI-Gateway DG/S 8.1 with the application program Dim Slave Lightscenes Dynamic

More information

ABB i-bus EIB / KNX Weather Station WS/S 4.1

ABB i-bus EIB / KNX Weather Station WS/S 4.1 Product Manual ABB i-bus EIB / KNX Weather Station WS/S 4.1 Intelligent Installation Systems This manual describes the function of the Weather station WS/S 4.1. Subject to changes and errors excepted.

More information

KNX Panasonic Air Conditioners

KNX Panasonic Air Conditioners IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line

More information

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer) Operating Manual for the Electronic Built-in Interval Timer Micro II (Countdown Timer) Note: This document has been designed for our OEM customers. They can use it as supporting material when creating

More information

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two

More information

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB i-bus KNX SA/S Switch Actuators Product Manual ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

Operating instructions. RCD flat 4-fold, 6-fold

Operating instructions. RCD flat 4-fold, 6-fold Operating instructions 1. Safety instructions Electrical equipment must be installed and fitted by qualified electricians only. Observe the current accident prevention regulations. Failure to observe the

More information

UniPi technical documentation REV 1.1

UniPi technical documentation REV 1.1 technical documentation REV 1.1 Contents Overview... 2 Description... 3 GPIO port map... 4 Power Requirements... 5 Connecting Raspberry Pi to UniPi... 5 Building blocks... 5 Relays... 5 Digital Inputs...

More information

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RVL470. Heating Controller. Building Technologies HVAC Products. Series B 2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

Dupline Car Park System Type GP6220 330x 724-US 3-Colour Ultrasonic Sensor

Dupline Car Park System Type GP6220 330x 724-US 3-Colour Ultrasonic Sensor Dupline Car Park System Type GP6220 330x 724-US 3-Colour Ultrasonic Sensor Product Description GP6220 330x 724-US is an ultrasonic sensor with a built-in 3 colour LED indicator and part of the Dupline

More information

Digi-Motor Installation Guide

Digi-Motor Installation Guide Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support

More information

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay

More information

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply 1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

OZW30. Central Unit SYNERGYR

OZW30. Central Unit SYNERGYR 2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control

More information

Solar Controller / Battery Charger User s Manual

Solar Controller / Battery Charger User s Manual Solar Controller / Battery Charger User s Manual 1 Congratulations! You have made an excellent choice by purchasing this high quality KORR PWM solar controller which has been manufactured to the highest

More information

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10 ABB ABB Schweiz AG Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205 09.04.2014 Page: 8201 Schaffhausen 1 / 10 Please use also the assembly instruction S800-RSU-H Remote

More information

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the

More information

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10 Programmable thermostat Thermostat programmable Termostato programable Read and save these instructions. Veuillez lire le mode d

More information

Intelligent Installation Systems. ABB i-bus KNX Room Thermostat Fan Coil with Display 6138/11-xx-500 Product Manual

Intelligent Installation Systems. ABB i-bus KNX Room Thermostat Fan Coil with Display 6138/11-xx-500 Product Manual Intelligent Installation Systems ABB i-bus KNX Room Thermostat Fan Coil with Display 6138/11-xx-500 Product Manual TemABB i-bus KNX Contents and document history Page 1 General...3 1.1 Overview of Product

More information

Combi switchbox with integrated 3/2 way pilot valve

Combi switchbox with integrated 3/2 way pilot valve H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled

More information

Heating Controller. Building Technologies HVAC Products

Heating Controller. Building Technologies HVAC Products 2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or

More information

Automatic Telephone Dialer TD-101(W)

Automatic Telephone Dialer TD-101(W) Automatic Telephone Dialer TD-101(W) The TD-101 is an automatic dialing device which can transmit prerecorded information via the telephone line. The dialer can send two different 10 second voice messages

More information

Technical Manual MDT Rain sensor

Technical Manual MDT Rain sensor 9/2012 Technical Manual MDT Rain sensor SCN-RS1R1.01 Technical Manual Rain sensor SCN RS1R1.01 1.1. Settings at the ETS Software Selection at the product database: Manufacturer: MDT Technologies Product

More information

ABB i-bus KNX IP Router IPR/S 2.1

ABB i-bus KNX IP Router IPR/S 2.1 Product Manual ABB i-bus KNX IP Router IPR/S 2.1 Intelligent Installation Systems This manual describes the function of the IP Router IPR/S 2.1 with the application program IP Routing. Subject to changes

More information

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions DAI DIM/COVERTER COTRO (DC V) 1 10V (0-10 V) analog DAI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions Dim-and Switch Functions: The DAI Dim/Converter Control DC V is suitable

More information

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS.  Construction Automotive Industry DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS www.rehau.com Construction Automotive Industry SCOPE This guide gives instruction regarding REHAU Programmable Digital Thermostat installation and operation.

More information

REGTRONIC OPERATING INSTRUCTIONS

REGTRONIC OPERATING INSTRUCTIONS REGTRONIC OPERATING INSTRUCTIONS 1.FEATURES Electrical connection: M12 8-pin connector Preset pressure range 0.05-10 bar with possible full scale regulation. 10 100 mbar adjustable deadband Supply pressure:

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Actuator for modulating control AME 435

Actuator for modulating control AME 435 Data sheet Actuator for modulating control AME 435 Description The actuator automatically adapts its stroke to the valve end positions which reduces commissioning time (self stroking). The advanced design

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-23 09 93 (November 2015) ----------------------------- Preparing Activity: USACE Superseding UFGS-23 09 23 (May 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

ABB i-bus KNX Security Terminals MT/U 2.12.2, MT/S 4.12.2M and 8.12.2M Product Manual

ABB i-bus KNX Security Terminals MT/U 2.12.2, MT/S 4.12.2M and 8.12.2M Product Manual ABB i-bus KNX Security Terminals MT/U 2.12.2, MT/S 4.12.2M and 8.12.2M Product Manual Contents Contents Page 1 General 3 1.1 Use of the product manual...3 1.1.1 Structure of the product manual...3 1.1.2

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ TSQ--0 7-7-07 T Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T SQ Model Configuration T SQ- Heating / Cooling Border Type (Lay-In) Full Face Nominal Round Duct Size

More information

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves

More information

PRESENCE DETECTOR PD-C360i/24 KNX ECO (EP10425844)

PRESENCE DETECTOR PD-C360i/24 KNX ECO (EP10425844) In the Master function, the remote control entries will be acknowledged as follows: acknowledged 3 x with the red LED In the Slave function, each detection is acknowledged 2 x with the green LED. 6 TEST

More information