ABL1 Power Supplies. Class Catalog June
|
|
|
- Norma Moore
- 9 years ago
- Views:
Transcription
1 Catalog June 05 Class 8440 CONTENTS Description Page Product Description Selection Specifications and Characteristics Technical Overview Dimensions and Wiring Diagrams Mounting Instructions Catalog Number Index
2 Schneider Electric All Rights Reserved 06/2005
3 Product Description PRODUCT DESCRIPTION The characteristics to consider when selecting a power supply are: the supply voltage available in the installation, the required output voltage and current. This may, however, result in several products being selected as suitable. Therefore, other selection criteria must be considered. Power Supply Voltage The ABL1 range is the solution because it guarantees regulation of 3% on the output voltage, whatever the load current and the input voltage. In addition, the wide input voltage range of ABL1 power supplies allows them to be connected to all voltage supplies within this range, without any adjustment on 60 and 100 W versions, and via a selector on 150 and 240 W versions. Short Circuit Protection ABL1 power supplies are equipped with electronic and thermal overload protection. This protection resets itself automatically on elimination of the fault, which avoids having to take any action or change a fuse. Electromagnetic Compatibility Levels of conducted and radiated emissions are defined in standards EN and EN The products in the ABL1 range are class B, the strictest level, and can be used without any restrictions due to their low emissions. Power Factor The current drawn by a power supply is not sinusoidal. This leads to the existence of harmonic currents which pollute the voltage supply. Regulated switch mode supplies always produce harmonic currents; therefore, a filter circuit (Power Factor Correction or PFC) must be added to comply with standard EN ABL1RPM power supplies conform to standard EN and can therefore be connected directly to public voltage power supplies. 06/ Schneider Electric All Rights Reserved 3
4 Product Description ABL1 regulated switch mode power supplies are designed to provide the dc voltage necessary for simple, dedicated control circuits. Divided into two families, these power supplies are able to meet all the needs encountered in standard commercial machines. These single-phase power supplies, with or without anti-harmonic distortion filtering, conform to world-wide standards. Switch mode technology guarantees the quality of the output current with regulation below 3%. As machine components, ABL1 power supplies are easy to install only the setup may vary from one application to another. The ABL1 range is specially designed for machine manufacturers ABL1 regulated switch mode power supplies are totally electronic and regulated, and provide the following benefits: A wide input voltage range from Vac and either Vdc or Vdc (not indicated on the product). Output currents ranging from A. Products with anti-harmonic distortion input filtering (ABL1RPM). A high degree of output voltage stability, adjustable by potentiometer. Built-in thermal overload and short-circuit protection. Conformity to world-wide standards. Conformity to standard EN class B. UL508, CSA, and CE certifications. Considerably reduced weight in comparison to competition lb ( kg). Two optional mounting accessories to fit all models. ABL1 power supplies for electrical equipment are split into two families: ABL1REM, single-phase: 60 W for the 12 Vdc version 60 W, 100 W, 150 W and 240 W for the 24 Vdc versions ABL1RPM, single-phase with anti-harmonic distortion filtering: 100 W for the12 Vdc version 100 W, 150 W and 240 W for the 24 Vdc versions ABL1 regulated switch mode power supplies are comprised of: 1. Two holes for M4 x 20 screws. 2. A 115/230 V input voltage selector (150 and 240 W versions only). 3. A green LED indicating presence of the dc output voltage. 4. An output voltage adjustment potentiometer (± 10%). 5. A removable, transparent, clip-on cover Schneider Electric All Rights Reserved 06/2005
5 Selection SELECTION ABL1REM24025 ABL1REM Single-Phase Regulated Switch Mode Power Supplies Input Voltage Hz Vac (1) single-phase wide range / Vac (2) single-phase Output voltage Nominal power Nominal current Automatic Protection Reset Conforms to standard EN Catalog Number Weight lb (kg) 12 Vdc 60 W 5 A Automatic No ABL1REM (0.44) 24 Vdc 24 Vdc 60 W 2.5 A Automatic No ABL1REM (0.44) 100 W 4.2 A Automatic No ABL1REM (0.64) 150 W 6.2 A Automatic No ABL1REM (0.73) 240 W 10 A Automatic No ABL1REM (0.88) ABL1RpM24042 ABL1RpM24062 ABL1RPM Single-Phase Regulated Switch Mode Power Supplies Input Voltage Hz Vac (1) single-phase wide range / Vac (2) single-phase Output voltage Nominal power Nominal current Automatic Protection Reset Conforms to standard EN Catalog Number Weight lb (kg) 12 Vdc 100 W 8.3 A Automatic Yes ABL1RPM (0.64) 24 Vdc 100 W 4.2 A Automatic Yes ABL1RPM (0.64) 24 Vdc 150 W 6.2 A Automatic Yes ABL1RPM (0.97) 240 W 10 A Automatic Yes ABL1RPM (1.23) ABL1RpM24100 Mounting Accessories Description Sold in lots of Catalog Number Weight lb (kg) Reversible mounting bracket 5 ABL1A01 (3) 0.20 (0.085) Clip-on mounting plate for 35 mm mounting rail 5 ABL1A02 (3) 0.09 (0.035) (1) Compatible input voltage Vdc not indicated on the product. (2) Compatible input voltage Vdc not indicated on the product. (3) Can be used with any ABL1 power supply. ABL1REM, RPM E NMTR E NMTR / Schneider Electric All Rights Reserved 5
6 Specifications and Characteristics SPECIFICATIONS AND CHARACTERISTICS Catalog Number ABL1REMppppp ABL1RPMppppp Technical Characteristics Input Circuit Output Circuit Operating Characteristics Approvals culus, ccsaus, TÜV / CTick, e Conforming to Products UL508, CSA 22.2 n , UL standards Safety EN , SELV Generic EMC EN , EN Low frequency harmonic currents No EN LED indication None Input voltages Rated values Vac (60 and 100 W), / Vac (150 and 240 W) Permissible values Vac (60 and 100 W), / Vac (150 and 240 W) Vdc(60 and 100 W), Vdc(150 and 240 W) compatible Frequency Hz Efficiency at nominal load > 80 % Current Ue = 240 V 1 W / 0.7 W / 2.5 W / 3 W consumption Ue = 100 V 2 W / 1.4 W / 5 W / 6 W Current at switch-on < 50 A Power factor 0.65 % approx. 0.7 to 0.95 % approx. (depending on model) LED indication Green LED Nominal output voltage (U out) 12 or 24 Vdc Nominal output current 5 A, 8.3 A at 12 V; 2.5 A, 4.2 A, 6.2 A, 10 A at 24 V Precision Output voltage ± 10 % Line and load regulation ± 3 % Residual ripple < 200 mv (peak to peak) Micro-breaks Holding time at 40 ms I max and Ue = 240 V Holding time at 10 ms I max and Ue = 100 V Temporary overloads See graph on page 8 Protection Short-circuit Permanent, automatic restart Overload 1.1 to 1.5 in Overvoltage U > 1.25 U out Thermal Yes (limiting operation above a temperature between 122 and 140 F (50 and 60 C), depending on the load rating) Protection class 1 Degree of pollution 2 Overvoltage category II Connections Input 2 x 4 mm 2 + ground Output 2 x 4 mm 2 (60 W) doubled for 100, 150 and 240 W Tightening torque 7.0 lb-in (0.8 Nm) Ambient conditions Storage temperature - 13 to 185 F (- 25 to +85 C) Operating temperature See graphs on page 7 Maximum relative humidity % RH Degree of protection Conforming to standard EN with clip-on cover over connection terminal block Vibrations Exceeding standard EN (5 9 Hz: 3.5 mm; Hz: 2 g) Operating position All positions with derating MTBF at 104 F (40 C) > h at 100% load Connections Serial Possible (2 power supplies maximum) Parallel Possible (2 power supplies maximum) Dielectric strength Input/output 3000 V / 50 and 60 Hz / 1 min Input/ground 1500 V / 50 and 60 Hz / 1 min Output/ground 500 V / 50 and 60 Hz / 1 min Input fuse incorporated Yes Emissions Generic EN Conducted/radiated EN 55011, EN Class B Immunity Generic EN Electrostatic discharge EN level 3 (4 kv contact/8 kv air) Electromagnetic discharge EN level 3 (10 V/m) Conducted interference EN level 3 (2 kv), EN , EN level 3, EN level 4, EN level 3 Supply interference Conforming to standard EN (voltage drops and cuts) Schneider Electric All Rights Reserved 06/2005
7 Technical Overview TECHNICAL OVERVIEW OUTPUT CHARACTERISTICS Derating The ambient temperature is a determining factor that limits the power that an electronic power supply can deliver continuously. If the temperature around the electronic components is too high, their life will be significantly reduced. ABL1RpM24100 (240 W) power supplies are mechanically ventilated as from an approximate ambient temperature > 104 F (40 C) or for an approximate load rating > 90%. The rated ambient temperature for ABL1 power supplies is 122 F (+ 50 C). Above this, derating is necessary up to a maximum temperature of 140 F (+ 60 C). The graphs below show the power (in relation to the nominal power) which the power supply can deliver continuously, according to the ambient temperature. P/P N 100 % 60 % 32 F/ 0 C 122 F/ 50 C Tp ( F/ C) 140 F/ 60 C P/P N 100 % 60 % 32 F/ 0 C 113 F/ 45 C Tp ( C/ F) 131 F/ 55 C Derating should be considered in the following extreme operating conditions: intensive operation (output current permanently close to the nominal current, combined with a high ambient temperature) output voltage set above 24 V (to compensate for line voltage drops, for example) parallel connection to increase the total power General rules to follow: (See graphs above for derating information.) Intensive operation Rise in output voltage Parallel connection to increase the power Example for ABL1 mounted vertically: without derating, from 32 F to 122 F (0 C to 50 C), derating of nominal current by 4%, per additional C, up to 140 F (60 C). The nominal power is fixed. Increasing the output voltage means that the current delivered must be reduced. The total power is equal to the sum of the power supplies used, but the maximum ambient temperature for operation is 122 F (50 C). To improve heat dissipation, the power supplies must not be in contact with each other. 06/ Schneider Electric All Rights Reserved 7
8 Technical Overview Output Characteristics, continued... In all cases, there must be adequate convection around the products to ensure proper cooling. There must be a clear space of 1.97 in. (50 mm) above and below the power supplies, and of 0.79 in. (20 mm) on the sides. 1.97/ / / / / / Dimensions are in inch/mm LOAD LIMITS U out 24 V 15 V I out 0 In x 1,1 In x 1,5 In Serial or parallel connection Serial connection Parallel connection ABL1 ABL1 ABL1 ABL (1) (1) (1) 8 A/100 V Shottky diode for ABL1REM12050/1REM24025/1RpM A/100 V Shottky diode for ABL1RPM12083/1RpM24062/1RpM Protection Devices for ABL1 Power Supplies For use with 120 Vac Single-Phase 240 Vac Single-Phase Thermal-magnetic circuit-breaker gg fuse Thermal-magnetic circuit-breaker gg fuse GB2 MG GB2 MG ABL1REM12050 DB A DB A ABL1REM24025 DB A DB A ABL1RPM12083 DB A DB A ABL1REM24042 DB A DB A ABL1RPM24042 DB A DB A ABL1REM24062 DB A DB A ABL1RPM24062 DB A DB A ABL1REM24100 DB A DB A ABL1RPM24100 DB A DB A Schneider Electric All Rights Reserved 06/2005
9 Dimensions and Wiring Diagrams DIMENSIONS AND WIRING DIAGRAMS Dimensions ABL1RpMppppp Part Number L (in/mm) P (in/mm) a (in/mm) ABL1REM / / / ABL1REM / / / ABL1RPM / / / ABL1RPM / / / ABL1RPM / / / ABL1RPM / / / /8.38 a 0.31/ / /98.04 L 0.10/ /7.87 P ABL1A / / / / / / / Dimensions are in inch/mm Wiring Diagrams ABL1REM12050, 1REM24025 ABL1REM24042, 1REM24062, 1REM24100 N L N L ABL1RPMppppp N L Filter 06/ Schneider Electric All Rights Reserved 9
10 Mounting Instructions MOUNTING INSTRUCTIONS 0.33/8,5 (1) Mounting the ABL1 ABL1 power supplies can be mounted directly, without accessories using the provided holes, (A) and (B). See figure to the left. Dimensions are in inch/mm M4 x 20/# 8 x 32 (A) M4 x 20/# 8 x 32 (B) 0.10/2,5 0.31/8 0.31/8 3.23/82 Mounting Bracket ABL1A01 To minimize the amount of space required, the power supplies can be mounted by the base using mounting bracket ABL1A01. This type of mounting is not recommended in the case of persistent vibrations or for onboard equipment. (1) 5.67/ for ABL1REM12050 and ABL1REM / for ABL1REM12083 and ABL1RpM24042/24062/ xØ xØ , Dimensions are in inch/mm Mounting Plate ABL1A02 Mounting plate ABL1A02 enables mounting on a 35 mm mounting rail. ABL1REM12050/ ABL1RPM12083 ABL1RpM24042/24062/ ABL1RpMppppp c b " " a Dimensions are in inch/mm ABL a in/mm b in/mm c in/mm 1REM / / / REM RPM RpM RpM / / / RpM / / / Schneider Electric All Rights Reserved 06/2005
11 Indexed Catalog Numbers INDEXED CATALOG NUMBERS ABL1A01 5 ABL1A02 5 ABL1REM ABL1REM ABL1REM ABL1REM ABL1REM ABL1RPM ABL1RPM ABL1RPM ABL1RPM NOTE: Protective devices are listed on page 8. 06/ Schneider Electric All Rights Reserved 11
12 Schneider Electric USA 2641 Sumner Blvd Raleigh, NC USA Square D CT Schneider Electric All Rights Reserved 06/2005
7 - Phaseo power supplies and transformers
/0 Contents 0 - Phaseo power supplies and transformers Selection guide: Phaseo power supplies Modular, Optimum and universal ranges........................ page /2 Selection guide: Phaseo power supplies
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Phaseo power supplies
ABL1, ABL7 and ABL8 Catalog 2011 2 Contents Product data website....4 Selection guides...................................... 6 Overview........................................... 10 Product descriptions:
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
Relés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class
MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
Analog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
EPL225 Series. 225 Watts. www.xppower.com. AC-DC Power Supplies. Models & Ratings. Summary
225 Watts 50 W Convection/ 225 W Forced-cooled Ratings 2 by 4 Footprint Low.26 Profile 2 V Fan Output High Efficiency, up to 95% ITE & Medical pprovals High Power Density Less than 0.5 W No Load Input
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number: 900-4602-0000
Electrical Specification for: CPCI-3U-AC-300W-R Rugged 300W AC Input 3U CompactPCI Power Supply Telkoor Part Number: 900-4602-0000 GENERAL SCALE RELEASE DATE 12/9/06 SHEET 1 OF 6 REVISION HISTORY Rev Level
LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly
Overview Safety instructions 1 Power supply Operating Instructions Description, device design, dimension drawing 2 Mounting/disassembly 3 Mounting position, mounting clearances 4 Installation 5 Technical
Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1
Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/2x15DC/1 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of
Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2
Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/24/2 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of operational
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
Single Output Switching Power Supply
.. RS- Code: CLP-A Single Output Switching Power Supply SPECIFICATION MODEL OUTPUT INPUT PROTECTION ENVIRONMENT SAFETY EMC (Note 6) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications
Features UniversalACinput/Fulrange Built-inactivePFCfunction Higheficiencyupto91% Protections:Shortcircuit/Overcurent/ Overvoltage/Overtemperature Fanlesdesign,colingbyfreairconvection Colingbyfreairconvection
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
Actuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA
Highlights & Features Reliable design, with expected life of 10 years Compact, rugged design for ease of handling and installation Multiple connections to terminals allowed Designed for Class I Div. 2
Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
650W Single Output Power Supply
AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter
FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current
AC-DC Single Output Power Module
AC-DC Single Output Power Module PFHC (AC-DC Conversion) and DC-DC Conversion Integrated in One Package. 2-in-1 Design Concept One module now contains the functions previously only obtainable by combining
CQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
Manual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models
TML Series, 0 & 0 Watt Features C B Scheme LVD UL 090- Encapsulated power supplies with increased power density Replaces TML and TML 0 series PCB mount or chassis mount with screw terminals Single, dual
Operating Manual UWAPS-TINY Series
Operating Manual UWAPS-TINY Series Powecon Oy WWW.POWECON.FI 1/9 Table of content 1 Warranty...3 2 Safety information...3 3 Abbreviations and terminology...3 4 List of appendices...4 5 Introduction...4
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA
Highlights & Features Universal AC input voltage Power will not de-rate for the entire input voltage range Power Boost of 150% for 3 seconds Full corrosion resistant aluminium chassis SEMI F47 certified
LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2
Overview Description, device design, dimension drawing 1 Power supply Operating Instructions Mounting/Disassembly 2 Mounting position, installation clearances 3 Installation 4 Applications 5 Technical
Silvertel. Ag5200. 1 Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power
Silvertel V1.1 November 2012 Datasheet Pb 1 Features IEEE802.3at and IEEE802.3af compliant Maximum 30W output power Dual In-Line (DIL) package size 50.6mm (L) x 30mm (W) Overload, short-circuit and thermal
7.5 Watt AC-DC Switch Power Supply
MAIN FEATURES: 7.5W Small Compact Size PCB Mount Single Output Regulated Output Range : 3.3VDC 24VDC Input Range : 85VAC 265VAC/47 63Hz Or 120VDC 370VDC Very Low Standby Power Consumption < 0.15W Better
Power Supplies 3. SDN-C Compact DIN Rail Series
Power Supplies 3 SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual
UMEC International Corporation
UP1301A SERIES 130 Watt Open Frame Switchers Small Size 3*5*1.2(inches) Universal Input to 264 VAC Low Power Consumption Overvoltage Protection Continuous Short Circuit Protection Over Temperature Protection
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
Industrial Power Supplies
TSP-Series Innovative and Powerful Features! Rugged metal case for harsh industrial environments Shock and vibration proof Worlwide Safety approval package. ATEX certification tested in accordance to IECEX
Energy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
Specification guide no. 9 Active harmonic conditioner from 20 to 480 A
Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Bimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
Technical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
NFF Series. CoolX600 NFF Series Cool. Patented Resonant Technology. NFF Series; No Fan Featured
Cool TM 600 NFF Series Patented Resonant Technology NFF Series; No Fan Featured 100% natural convection cooled No internal or external fans needed No base-plate needed No Acoustic Noise or Vibrations &
Radiant Temperature Sensor TY7321
AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional
PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.
PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering
34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51
34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in
Datasheet. Arrant-Light Oy. 120W DR Series 3.8.2015
3.8.2015 Arrant-Light Oy Datasheet 120W DR Series DR120 Series 120W Single Output LED Driver Features: Constant current and voltage output Universal AC input 100~305VAC Built in active PFC function Output
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
Absolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the