Live Tank Circuit Breaker

Size: px
Start display at page:

Download "Live Tank Circuit Breaker"

Transcription

1 Live Tank Circuit Breaker Auto-Puffer TM SF6 Circuit-breakers for outdoor installation Rated voltages kV Rated currents 4000A Rated breaking currents 50kA

2 Content LTB FAMILY Contents I. Introduction...1 II. Design Feature Auto-Puffer TM...2 III. LTB Design Features and Advantages...4 IV.Technical Data According to ANSI...12 V. Technical Data According to IEC...13 VI. Dimensions-LTB...14 VII. Shipping Data for LTB...16

3 LTB FAMILY Introduction Introduction Exceeding Customer Expectations -ABB Live Tank Circuit Breakers ABB has over a century of experience in developing, testing and manufacturing high voltage circuit breakers. Through the years, our circuit breakers have acquired a reputation for high reliability and long life in all climates and in all parts of the world. ABB s LTB circuit breaker family, with rated voltage kv and breaking current up to 50 ka, satisfies the highest demands. It is based on latest developments in dielectric dimensioning and arc physics research. ABB produced the world s first SF 6 circuit breakers with arc-assisted interrupters in the mid-1980 s - Auto-Puffer TM.The energy required for interrupting short circuit currents is partly taken from the arc itself,significantly reducing the energy required from the operating mechanism. Lower operating energy inherently reduces mechanical stresses, on the circuit breaker itself as well as on the foundation, and increases circuit breaker reliability. For many years, ABB has used operating mechanisms with energy mechanically stored in springs. This solution offers considerable advantages in that the energy in the tensioned springs is always available. The design of the LTB is a well-proven technology (over 20,000 units are in service). = Brief Performance Data: Installation Design Outdoor/Indoor SF6 Auto-Puffer TM interrupter spring operating mechanisms Insulation SF 6 Rated kv Rated Current 4,000 A Breaking Current 50 ka Short Time Current 50 ka/3 s Insulators Composite or Porcelain Creepage Distance 25 mm/kv (longer on request) Service Condition Ambient Temperature - 30 to+40 Operation in temperature down to -55 or up to+70 Design Altitude 1,000 m.a.s.l. Higher altitude on reques Type of Operation Single- or Three- pole 1

4 Auto-Puffer TM LTB FAMILY Design Feature Auto-Puffer TM Design Feature Auto-Puffer TM Interrupters Contact Parting Closed Main Arcing ValveOperation Arc Extinction Open 1. Upper current carrier 2. Stationary arcing contact 3. Moving arcing contact 4. Auto-Puffer TM volume 5. Puffer volume 6. Refill valve 7. Stationary piston 8. Nozzle 9. Stationary main contact 10. Moving main contact 11. Auto-puffer? valve 12. Puffer cylinder 13. Over-pressure relief 14. Lower current carrier When interrupting high currents (e.g. rated shortcircuit current), Auto-Puffer TM interrupters show the advantage they were designed to provide. On opening, the operation of an Auto-Puffer TM interrupter at high current begins the same way as a puffer interrupter. It is not until after arcing begins that a difference in the operation principle is seen between the high and low current interrupting cases. When the arcing contacts part, an arc is drawn between the moving and stationary arcing contacts. As the arc flows, it to some degree blocks the flow of SF 6 gas through the nozzle. The arc drawn is extremely hot and radiates a lot of heat and begins to heat the SF 6 gas in the interrupting gas volume. Thus, the pressure inside the Auto-Puffer TM and puffer volumes increases due to the rise in temperature as well as due to the com-pression of gas between the puffer cylinder and stationary piston. Gas pressure inside the Auto-Puffer TM volume continues to increase until it is high enough to force the Auto-Puffer TM valve to the closed position. All SF 6 gas required for interruption is now trapped in the fixed Auto-Puffer TM volume and any further increase in gas pressure in that volume is due solely to heating from the arc. At about the same time, the gas pressure in the puffer volume reaches a level sufficient to push the overpressure valve open. Since the gas in the puffer volume escapes through the overpressure valve, Design Features Auto- Puffer TM Interrupters there is no need for a high operating energy to overcome the compression of 2

5 LTB FAMILY Auto-Puffer TM Design Feature Auto-Puffer TM Interrupters SF 6 gas while at the same time maintaining the contact speed necessary to withstand recovery voltage. When the current waveform crosses zero, the arc becomes relatively weak. At this point, the pressurized SF6 gas flows from the Auto-Puffer TM volume through the nozzle extinguishing the arc. When interrupting low currents, Auto-Puffer TM interrupters act in much the same way as puffer interrupters. That is, there is not sufficient gas pressure generated to force the Auto-Puffer TM valve closed. Thus, the fixed Auto-Puffer TM volume and puffer volume form one large puffer volume. In such a case, the SF 6 gas pressure required for interruption is built up by mechanical means as in a puffer interrupter. Unlike a puffer nterrupter, however, Auto-Puffer TM need only mechanically generate sufficient gas pressure to interrupt a portion of the rated short-circuit current (i.e. 20% to 30%) In the open position, there is sufficient distance between the stationary and moving contacts to withstand rated dielectric levels. On closing, the refill valve opens so that SF 6 gas can be drawn into the Auto-Puffer TM and puffer volumes.because interruption of low currents requires only moderate build up of SF 6 gas pressure by mechanical means and since high current interruption uses heating from the arc to generate necessary gas pressure in a fixed volume, Auto- Puffer TM interrupters require far less operating energy than puffer interrupters (i.e. about 50% less). ABB Auto-Puffer TM interrupter is also a single motion design. 3

6 Design Features and Advantages LTB FAMILY Design Features LTB Design Features and Advantages LTB is available for single- or three-pole operation. For circuit breakers with one breaking element per pole, both modes of operation are possible. For three-pole operation, the circuit breaker poles and the operating mechanism are linked together with pull rods. On every pole there is an individual opening spring controlled by the pull rod. There is however one exception. In the LTB D three-pole operation case there is only one opening spring cntrolling all three poles and it is mounted on the pole furthest away from the operating mechanism. Each circuit breaker pole constitutes a sealed SF 6 filled unit, which includes the breaking unit, the hollow post insulator and the mechanism housing Circuit Breaker type LTB D 1. Breaking Chamber 2.Support Insulator 3.Support Structure 4.Operating Mechanism type BLK 5. Trip Spring 6.Gas Tube with Protective Beam 7.Gas Supervision (On opposite side) 8. Drilled Holes for Connection to Ground 9. Pull rod with Protective Tube 10. Position Indicator Note: 5, 6,9 are inside the horizontal beam 4

7 LTB FAMILY Design Features and Advantages The three poles of the circuit breaker can be mounted on individual pole supports or in the case of LTB D on a common support frame (pole beam). BLK is used for: LTB D kv LTB E kv Single-pole operation BLG is used for: LTB E kv Three-pole operation The operational reliability and the service life of an SF 6 circuit breaker is very much dependent on the ability to ensure sealing of the SF 6 gas volume and to neutralize the effects of moisture and decomposition products in the gas. The risk for gas leakage is negligible; double nitrile rubber O-rings and X-rings are used with excellent result. Dielectric Strength LTB has high dielectric strength even at atmospheric SF 6 pressure, due to optimized contact gap. Controlled Switching As option LTB circuit breakers can be used for controlled switching by applying our controlling device type Switchsync TM.For further information please see chapter O-1 Controlled Switching. Stable Operating Times For controlled switching it is of the utmost importance that the functional times for closing and tripping operations are constant. We can guarantee 1 ms for all LTB circuit breakers. Each breaking unit is provided with a desiccant, which absorbs the moisture and the decomposition products from the interruption process. Since the interrupting capability is dependent on the density of the SF 6 gas, the LTB circuit breaker is provided with a density monitor.the density monitor consists of a temperature compensated pressure switch. Therefore, alarm signal and blocking function are activated only if the pressure drops due to leakage. The design corresponds with the demands in the standards IEC and ANSI. Special design solutions to meet other standards and/or specifications are also available. Current Switching Capability All LTB circuit breakers are capable of interrupting short-circuit currents in a maximum of 40 ms. We can also guarantee restrike free interruption of capacitive currents due to optimized contact design and movement. For inductive current switching the over-voltages are low as a result of optimum quenching at current zero. 5

8 Design Features and Advantages LTB FAMILY Material Seismic Withstand Strength The selected components of aluminum (mechanism housings, HV-terminals, cubicles) give a high degree of resistance to corrosion, without the need of extra protection. For use in extreme trying environments LTB can be delivered with a protective painting. The support structure and protective tubes for the pull rods are made of hot-dipped galvanized steel Insulators LTB circuit breaker is as standard delivered with insulators that consist of high-grade brown-glazed porcelain or composite insulators (light gray). LTB with light gray porcelain can be delivered on request. LTB is available as standard with long creepage distances. All LTB circuit breakers can in their standard versions, withstand seismic accelerations up to 3 m/s2 (0.3 g), LTBD up to 5 m/s2 in accordance with IEC 1166 and IEEE 693. Rating Plates A rating plate, which includes data for the circuit breaker, is placed on the operating mechanism cubicle. The rating plate is made of stainless steel with engraved text. Operating Mechanism The circuit breaker is operated by motor charged spring operating mechanism(s), which is installed in a compact splash proof and corrosion resistant housing, attached to the structure. Longer creepage distances can be quoted on request. One BLK is used for three-pole operation for LTB D kv. Mechanical Strength The mechanical durability gives a sufficient safety margin for normal wind loads and static and dynamic forces from conductors. Three BLK s are used for single pole operation for LTB D kv. Three BLK s are used for single pole operation for LTB E up to 245 kv. One BLG is used for three-pole operation for LTB E up to 245 kv. 6

9 LTB FAMILY Design Features and Advantages Sealing Systems for SF 6 Volume The sealing system consists of double nitrile rubber O-rings in all static seals and double X-rings in all dynamic seals. This type of sealings has been used in our circuit breakers for more than 30 years with excellent service record at varying climatic conditions. The SF 6 gas leakage is less than 0.5% per year. SF 6 Density Monitoring Since the interrupting capability is dependent on the density of the SF 6 gas, the LTB circuit breaker is provided with density monitor(s). All LTB E circuit breakers have one density monitor per pole. The density monitor consists of a temperature compensated pressure switch. Therefore, alarm signal and blocking function are activated only if the pressure drops due to leakage. The standard version of LTB D for kv has one common density monitor for all three poles. Alternatively LTB D can be provided with one density monitor per pole. Climatic Withstand The LTB circuit breakers are designed for, and are installed in, widely shifting conditions from polar to desert climate throughout the world. For circuit breakers installed in areas with extreme low temperatures there is a risk of condensation of the SF 6 gas. In order to avoid condensation consequences, one of the following gas-mixtures is used: SF 6 and N 2 SF 6 and CF 4 7

10 Design Features and Advantages LTB FAMILY Support Structure Support structures are included in the standard versions of the LTB circuit breakers. The support structures are made of hot-dipped galvanized steel. The standard versions for structures are: LTB D kv One support column per D=14(4X) LTB E all types One support column per pole For detailed information see Dimensions 338 The support structures are prepared for connection to ground by means of drilled holes on each leg. High Terminals Drilled holes for connection The LTB circuit breakers are as standard equipped with flat aluminum terminals with thickness 20 mm for LTB D and 28 mm for LTB E. The drilling pattern is in accordance with IEC and NEMA standards. Other dimensions (e.g. DIN) by means of adapters, are available on request. Circuit breakers with vertically mounted breaking elements have terminals on both sides for connection in either direction. Circuit breakers with horizontal breaking elements have one terminal per breaking element. The terminals are directed upwards Ø14.5(13X)

11 LTB FAMILY Design Features and Advantages Controlled Switching Devices The goal for controlled switching is to increase power quality in the network systems by reducing switching transients. All LTB circuit breakers are suitable for controlled switching with ABB s Switchsync TM device. In order to obtain optimum result the switching instants should be different for the three phases. For three-pole operated circuit breakers this is achieved with mechanically staggered poles. Presently more than 1,000 HV live tank circuit breakers manufactured by ABB are in operation with controlled switching. Type Tests The LTB circuit breakers have been type tested in accordance with IEC and/or ANSI standards. Type test reports can be presented on request. Routine Tests All LTB circuit breakers are routine tested before delivery. Our test program complies with IEC and ANSI standards. Transport The LTB circuit breakers are normally packed and transported in seaworthy wooden crates.the circuit breaker poles with one breaking element per pole are transported as com-plete units. For circuit breakers with two breaking elements per pole, the breaking elements and the support insulators are transported in two separate cases. For detailed information regarding weights and dimensions see Shipping data. Breaking elements as well as support insulators are filled with SF 6 gas at a slight overpressure. Arrival Inspection On arrival the packaging and contents should be checked against packing list. In the event of damage to the goods, contact ABB for advice, before further handling of the goods takes place. Any damage ought to be documented (photographed). SF 6 gas Gas for filling up to rated pressure can be delivered in bottles, each containing 40 kg gas. The quantity required for each type of LTB varies from one circuit breaker type to an-other. This information is given in the tender. The pressurizing equipment can be delivered on request, and is described under Erection and Commissioning. 9

12 Design Features and Advantages LTB FAMILY Erection and Commissioning Assembly instructions are provided with each delivery. Erection work at site can be done in 1-4 days depending on LTB type and size. Filling of SF 6 gas to specified rated pressure is done by using the following pressuri-zing equipment, which can be delivered on request: One special control valve, for connection to the gas bottle, and a 20 m gas-filled hose with connectors. A complementary control valve for connection to CF4 or N2 gas bottle (for mixed gas filling). When using above equipment gas filling can be carried out without gas being released into the atmosphere. For illustration of gas filling equipment see page I-6. Maintenance LTB is designed for a service life of more than 30 years or 10,000 mechanical operations. For current switching the number of operations before service is dependent on the interrupted current and type of application. Inspection, maintenance and overhaul should be carried out at regular intervals de-pending on the ambient conditions and the number of operations. The general actions are described below: 1-2 years: Ocular inspection 7-10 years or 2,000 mechanical operations: Extended ocular inspection and some lubrication of the operating mechanism(s) years or 5,000 mechanical operations Preventive maintenance including general inspection of the circuit breaker and operating mechanism. Operation test including measurement of operating times and possible adjustments. 30 years or 10,000 mechanical operation: A comprehensive inspection is recommended to give increased safety and continued problem-free operation. The inspection methods and scope depend very much on the local conditions. For circuit breakers for special switching duties such as switching of reactor banks overhaul of the breaking chamber should be carried out more frequently, approximately 5,000 operations Overhaul and repair work must be performed by authorized personnel only. The instructions in the manual for operation and maintenance should be observed. ABB is available for discussions and advice. 10

13 LTB FAMILY Design Features and Advantages Recommended Spare Parts High operation frequency (e.g. circuit breakers for reactor or capacitor switching) and/or large quantities of circuit breakers: Complete poles Complete operating mechanisms Sets of contacts Sets of gaskets Density switches SF 6 gas Disposal The disposal of wasted parts should be carried out in accordance with local legal provisions. The SF 6 gas should not be released into the atmosphere when the circuit breaker is scrapped. The SF 6 gas can be recycled. The porcelain can, after it has been crushed, be used as fill. The metals used in the circuit breaker can be recycled. 11

14 Technical Data LTB FAMILY Technical Data According to ANSI LTB 72.5D1/B LTB 145D1/B LTB 170D1/B LTB 72.5E1 LTB 170E1 LTB 245E1 Number of breaks per pole Rated voltage kv Rated frequency Hz Power frequency withstand voltage - To earth (Dry/Wet) kv 160/ / / / / /350 -Across open pole(dry/wet) kv 160/ / / / / /350 Lightning Impulse Withstand - To earth kv Across open pole kv Chopped Wave Impulse Withstand To earth (2 s) kv Across open pole(2 s) kv Switching Impulse Withstand - To earth and/between phases kv Across open pole kv Creepage distance mm/kv Rated normal current A Rated s.c current ka First-pole-to-clear factor Rated closing and latching current ka Duration of short time withstand circuit s Closing time ms < 40 < 40 < 40 < 55 < 55 < 55 Opening time ms Break time ms Dead time ms Rated Standard Operating Duty - O-0.3s-CO-3min-CO or CO-15s-CO 12

15 LTB FAMILY Technical Data Technical Data According to IEC LTB 72.5D1/B LTB 145D1/B LTB 170D1/B LTB 72.5E1 LTB 170E1 LTB 245E1L Number of breaks per pole Rated voltage kv Rated frequency Hz Power frequency withstand level 1) - To earth and between phases kv Across open pole kv Lightning Impulse Withstand Level(LIWL) - To earth and between phases kv Across open pole kv Switching Impulse Withstand Level(SIWL) - To earth and/between phases kv Across open pole kv Creepage distance mm/kv Rated normal current A Rated s.c breaking current ka First-pole-to-clear factor Making current peak ka Duration of short circuit s Closing time ms < 40 < 40 < 40 < 55 < 55 < 55 Opening time ms Break time ms Dead time ms Rated Operating Sequence - O-0.3s-CO-3min-CO or CO-15s-CO 13

16 Dimensions-LTB LTB FAMILY Dimensions-LTB Dimensions -LTBD LTB D1/B Two-Column Stand, Three-pole Operation Rated : kv Dimensions(mm) Rated A B C D E F 72.5 kv kv kv Available dimensions for phase distances and heighes to lowest part of insulator(mm) E F E 267 Rated phase distances B 72.5 kv 1050* 1500* 1750* kv * kv A C *) Standard **)BIL550kV ated Height to lowest part of insulator** D 72.5 kv * *) Standard 2530 **) Other dimensions can be provided LTB D1/B Three-Column Stand, Three-pole Operation Rated : kv Dimensions(mm) Rated A B C D E F 72.5 kv kv F 170 kv E E 267 Available dimensions for phase distances and heighes to lowest part of insulator(mm) B Rated phase distances 72.5 kv 1050* 1500* 1750* kv * kv A C D *) Standard **)BIL550kV Rated Height to lowest part of insulator** kv * *) Standard **) Other dimensions can be provided 14

17 LTB FAMILY Dimensions-LTB Dimensions --LTBE LTB E1 Three-pole Operation Rated : kv Dimensions(mm) Rated A B C D E F 72.5 kv kv kv Available dimensions for phase distances and heighes to lowest part of insulator(mm) Rated phase distances 72.5 kv 1100* kv * kv *) Standard Rated Height to lowest part of insulator** kv * *) Standard LTB E1 Single-pole Operation Rated : kv Rated A B C D E F 72.5 kv kv kv *)Recommended phase distances Available dimensions for phase distances and heighes to lowest part of insulator(mm) Rated Height to lowest part of insulator** kv * *) Standard 15

18 Shipping Data for LTB D LTB FAMILY Shipping Data for LTB Shipping Data for LTBD LTB 72.5D1/B,Three-pole Operated, Three-Column Stand Equipment Number of Dimensions Gross Weight cases L x W x H (m) (Kg) Breaker Poles x 1.78 x Operating mechanism x 1.05 x Support Structure x 0.58 x Total m LTB 145D1/B,Three-pole Operated, Three-Column Stand Equipment Number of Dimensions Gross Weight cases L x W x H (m) (Kg) Breaker Poles x 1.78 x Operating mechanism x 1.05 x Support Structure x 0.58 x Total m LTB 170D1/B,Three-pole Operated, Three-Column Stand Equipment Number of Dimensions Gross Weight cases L x W x H (m) (Kg) Breaker Poles x 1.78 x Operating mechanism x 1.05 x Support Structure x 0.58 x Total m LTB 170D1/B,Three-pole Operated, Three-Column Stand Equipment Number of Dimensions Gross Weight cases L x W x H (m) (Kg) Breaker Poles x 1.78 x Operating mechanism x 1.05 x Pole Beam x 0.57 x Support Structure x 0.58 x Total m LTB 145D1/B,Three-pole Operated, Three-Column Stand Equipment Number of Dimensions Gross Weight cases L x W x H (m) (Kg) Breaker Poles x 1.78 x Operating mechanism x 1.05 x Pole Beam x 0.57 x Support Structure x 0.58 x Total m LTB 170D1/B,Three-pole Operated, Three-Column Stand Equipment Number of Dimensions Gross Weight cases L x W x H (m) (Kg) Breaker Poles x 1.78 x Operating mechanism x 1.05 x Pole Beam x 0.57 x Support Structure x 0.58 x Total m

19 LTB FAMILY Shipping Data for LTB E Shipping Data for LTB Shipping Data for LTBE LTB 72.5 and 170E1,Three-pole Operated, Three-Column Stand Equipment Number of Dimensions Gross Weight(Kg) cases L x W x H (m) LTB 72.5 Breaker Poles 1 on request on request - LTB 170 Breaker Poles x 1.90 x Operating Mechanism x 0.97 x Support Structure x 1.10 x LTB on request on request - LTB m LTB 72.5 and 170E1,Single-pole Operated, Three-Column Stand Equipment Number of Dimensions Gross Weight(Kg) cases L x W x H (m) LTB 72.5 Breaker Poles 1 on request on request - LTB 170 Breaker Poles x 1.90 x Operating Mechanism x 1.17 x Support Structure x 1.10 x LTB on request on request - LTB m LTB 245 E1-Three-pole Operated Equipment Number of Dimensions Gross Weight(Kg) cases L x W x H (m) Breaker Poles x 1.90 x Operating Mechanism x 0.97 x Support Structure x 1.10 x Total m LTB 245 E1-Single-pole Operated Equipment Number of Dimensions Gross Weight(Kg) cases L x W x H (m) Breaker Poles x 1.90 x Operating Mechanism x 1.17 x Support Structure x 1.10 x Total m

High-Voltage Circuit-Breakers 3AP1/2 72.5 kv up to 550 kv. Power Transmission and Distribution

High-Voltage Circuit-Breakers 3AP1/2 72.5 kv up to 550 kv. Power Transmission and Distribution High-Voltage Circuit-Breakers AP/ 7.5 kv up to 550 kv Power Transmission and Distribution The AP/ High-Voltage Circuit-Breakers Now Applicable for 550 kv Decades of our experience in high-voltage switching

More information

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

SF 6 Gas Insulated Switchgear Type SDF for 170 kv Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDF for 170 kv 06B1-E-0001 With Trustworthy Technology, Structure Fuji Electric as a manufacturer of comprehensive substation equipment

More information

www.siemens.com/energy High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

www.siemens.com/energy High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy. s www.siemens.com/energy High Voltage Circuit Breakers AP Type 7.5 kv to 800 kv Answers for energy. The AP High Voltage Circuit Breakers Available up to 800 kv Decades of our experience in high voltage

More information

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility

More information

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv High-Voltage Compact Switchgear AP1 DTC for 1 kv and kv Answers for energy. The AP1 DTC Complying with our Customers demands Experience you can rely on - at anytime, anywhere Decades of experience in high-voltage

More information

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation 2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation 123 kv Inductive Fingrid (Finland). 18 Instrument transformers igh voltage INTRODUCTION Inductive voltage transformers are designed

More information

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle Scope This specification stipulates the minimum requirements for mechanically linked three-phase electronic sectionalizers, for use on outdoor medium voltage overhead lines of 15, 27, and 38 kv. Electronic

More information

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed 2006-04

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed 2006-04 Circuit Breaker LTB D with Motor Drive Motor Drive ABB PP/H/HV - Page 1 Ed 2006-04 Technology Traditional technology Traditional spring operating mechanism: Closing mechanism ABB PP/H/HV - Page 2 Tripping

More information

Live Tank Circuit Breakers Application Guide

Live Tank Circuit Breakers Application Guide Live Tank Circuit Breakers Application Guide Edited by ABB AB High Voltage Products Department: Marketing & Sales Text: Tomas Roininen, Carl Ejnar Sölver, Helge Nordli, Anne Bosma, Per Jonsson, Anders

More information

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast. METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component

More information

1ZSE 2750-105 en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

1ZSE 2750-105 en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide 1ZSE 2750-105 en, Rev. 8 Transformer bushings, type GOE and GOE(2) Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS) August, 2009 Vertical Break Parallel (VBP) / Vertical Break Slant (VBS) Type VBPA (Aluminum) / Type VBPC (Copper) Type VBSA (Aluminum) / Type VBSC (Copper) PASCOR Air Break Switch Technology PASCOR offers

More information

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems Safe energy distribution that meets the highest industrial requirements NATUS switchgear systems your advantages minimal use of insulant

More information

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU George CURCANU, Constantin ILINCA, Ilie SBORA ICMET Craiova, Romania, Calea Bucuresti 144, phone:

More information

Outdoor vacuum circuit-breakers and reclosers for medium voltage. Switching technology for distribution networks. Answers for energy.

Outdoor vacuum circuit-breakers and reclosers for medium voltage. Switching technology for distribution networks. Answers for energy. Outdoor vacuum circuit-breakers and reclosers for medium voltage Switching technology for distribution networks Answers for energy. Reliable quality for all your medium-voltage network needs Quality from

More information

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd ACTOM OUTDOOR DISCONNECTORS Single Side Break (SSB) Disconnector 22-132 kv, 800-1 A, 25 ka - 3s Typical bearing assembly. Voltage range 11 kv to 132

More information

Erik Backström, High Voltage breakers, After Sales & Service High voltage SF 6 live tank circuit breakers After Sales & Service Training course

Erik Backström, High Voltage breakers, After Sales & Service High voltage SF 6 live tank circuit breakers After Sales & Service Training course Erik Backström, High Voltage breakers, After Sales & Service High voltage SF 6 live tank circuit breakers After Sales & Service Training course description HPL 72,5-300 B1 with BLG1002A Level A & B Training

More information

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support. www.ppcinsulators.com The very Best. The very Best. That s what we deliver. ong od Insulators Only a company that develops, produces and delivers products worldwide can provide the optimal solution for

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

Power transformers. Special transformers Railway

Power transformers. Special transformers Railway Power transformers Special transformers Railway A leader in railway systems Our compact and low-weight transformers fully comply with the customer s specifications. The products are developed together

More information

1ZSC000563-AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

1ZSC000563-AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide 1ZSC000563-AAC en, Rev. 7 Resin impregnated paper bushing, oil to air, type GSB Technical guide Original instruction The information provided in this document is intended to be general and does not cover

More information

UFES Active protection for switchgear

UFES Active protection for switchgear Active protection for switchgear ABB AG Oberhausener Strasse 4047 Ratingen, Germany Phone: +49 0-0 Fax: +49 0-7 77 Note: We reserve the right to make technical changes or modify the contents of this document

More information

Transmission Silicone Insulators Line Post 69 kv to 161 kv

Transmission Silicone Insulators Line Post 69 kv to 161 kv K-LINE INSULATORS LIMITED Catalogue T-LP Transmission Silicone Insulators Line Post 69 kv to 161 kv ISO9001 SAI GLOBAL FILE No. 000117 Transmission Silicone Insulators Line Post Today transmission lines

More information

3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG 11.05 2010

3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG 11.05 2010 Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.05 2010 Answers for energy. R-HG11-172.tif 2 Siemens HG 11.05 2010 Contents Contents Page 3AH5 Vacuum Circuit-Breakers Medium-Voltage

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING Training Title MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING Training Duration 5 days Training Date MV, HV and EHV Switchgear Testing & Commissioning 5 20 24 Apr $3,750 Dubai, UAE In any of the 5 star

More information

Gas-Insulated Switchgear up to 300 kv, 63 ka, 4000 A Type 8DN9. Answers for energy.

Gas-Insulated Switchgear up to 300 kv, 63 ka, 4000 A Type 8DN9. Answers for energy. Gas-Insulated Switchgear up to 300 kv, 63 ka, 4000 A Type 8DN9 Answers for energy. Gaining from experience Our switchgear ensures extraordinarily high availability at a low operating cost 2 Our 8D series

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

FAQs-Main switchboard design criteria

FAQs-Main switchboard design criteria FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard

More information

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003 MiCAFIL 1 RIP Technology Z. Zic 09/2003 )XQFWLRQRI+LJK9ROWDJH%XVKLQJ Uncontrolled (natural) electrical field Capacity-controlled electrical field %XVKLQJV0DLQ,QVXODWLRQ6\VWHPV 7\SH 0DLQ,QVXODWLRQ +RXVLQJFRYHU

More information

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

Medium voltage indoor circuit breakers ANSI/IEC solutions

Medium voltage indoor circuit breakers ANSI/IEC solutions Medium voltage indoor circuit breakers ANSI/ solutions Table of contents Introduction... 3 Vmax/A... 4 ADVAC... 6 AMVAC... 8 Vmax... 10 VD4... 12 VM1... 16 HD4... 19 V-Contact VSC... 22 2 Medium voltage

More information

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER. Power Voltage Transformers for Air Insulated Substations THE PROVEN POWER. Introduction Trench Power Voltage Transformers (Power VTs) combine the attributes of an inductive voltage transformer with the

More information

CAS 36 Ring Main Unit

CAS 36 Ring Main Unit Power distribution networks Ring Main Unit Catalogue 2008 A new path for achieving your electrical installations A comprehensive offer The range is part of a comprehensive offer of products that are perfectly

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

UGVCL/SP/591/11KV HT AB CABLE

UGVCL/SP/591/11KV HT AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched

More information

VD4. Vacuum circuit-breaker

VD4. Vacuum circuit-breaker VD4 Vacuum circuit-breaker VD4. The economical solution in power distribution. Applications: Power stations Transformer stations Chemicals industry Steel industry Automotive industry Airport power supply

More information

SIVACON The Versatile Low-Voltage Switchboard

SIVACON The Versatile Low-Voltage Switchboard s SIVACON The Versatile Low-Voltage Switchboard Type-Tested Power Distribution Board 8PT The Obvious Solution for Global Challenges SIVACON Type testing in low-voltage switchgear is increasingly becoming

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H. POWER SUPPLY SYSTEMS AND ELECTRICAL EQUIPMENT FOR DESALINATION PLANTS Y.M. Hamud and A.H. Anwar Abu Dhabi Water and Electricity Authority, Abu Dhabi, UAE Keywords : Electrical System, Network for Desalination,

More information

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon Type-Tested Power Distribution Board 8PT with Rear Busbars sivacon The Obvious Solution for Global Challenges SIVACON Type-testing is one of today s important issues for low-voltage technology and will

More information

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo Connectors, Clamps, Compensating Devices, Insulators and Safety Equipment for Overhead Catenary Lines RAILWAY CATENARY SYSTEMS Components and Systems for the Electrification of Railway Lines. Welcome to

More information

Low Voltage Products. Switches Automatic Transfer Switches

Low Voltage Products. Switches Automatic Transfer Switches Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,

More information

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c 91052 Erlangen Germany. www.siemens.

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c 91052 Erlangen Germany. www.siemens. Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c 91052 Erlangen Germany www.siemens.com/energy For questions on power transmission and distribution, please contact

More information

Disconnectors and Earthing Switches 36 kv up to 800 kv

Disconnectors and Earthing Switches 36 kv up to 800 kv Power Transmission and Distribution Disconnectors and Earthing Switches 36 kv up to 800 kv Ruhrtal & Siemens: A strong and successful team We manufacture high quality high-voltage disconnectors and earthing

More information

Outdoor circuit breaker GVR Recloser Hawker Siddeley Switchgear. rated voltage 15, 27 and 38 kv rated current 630 A

Outdoor circuit breaker GVR Recloser Hawker Siddeley Switchgear. rated voltage 15, 27 and 38 kv rated current 630 A Outdoor circuit breaker GVR Recloser Hawker Siddeley Switchgear rated voltage 15, 27 and 38 kv rated current 630 A Outdoor circuit breakers GVR Recloser GVR switchgear brings the reliability of modern

More information

Transformer Bushings for GIS

Transformer Bushings for GIS Transformer Bushings for GIS Oil to SF6 Connections GARIP RTKG 725-55 kv SQS certified ISO 91 / ISO 141 Bushings RIP - Technology for SF6 / Oil - Bushings In modern metal enclosed switchgear SF6 -gas is

More information

The standards mentioned in this document

The standards mentioned in this document The standards mentioned in this document Where can you order IEC publications? Central Offices of the International Electrotechnical Commission 1, rue de Varembé Geneva - Switzerland. The documentation

More information

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEB Standard 027: 1998 CEYLON

More information

The Intelligent AX1 Switchgear for Medium Voltage

The Intelligent AX1 Switchgear for Medium Voltage The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched

More information

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS Meher Capacitors offers reliable and innovative products and solutions in the fields of Reactive Power Compensation, Power Quality and Energy

More information

Technical catalogue About KOLEKTOR ETRA has been acting as transformer manufacturer over more than 75 years. Specializing in the manufacturing of power transformers rating up to 500 MVA and 420 kv the

More information

Capacitor Voltage Transformer. Answers for energy.

Capacitor Voltage Transformer. Answers for energy. Capacitor Voltage Transformer Answers for energy. Capacitor Voltage Transformer Siemens Capacitor Voltage Transformers are based on technology from Trench, a recognized world leader in the design and manufacture

More information

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is: 4 SENSORS The modern technical world demands the availability of sensors to measure and convert a variety of physical quantities into electrical signals. These signals can then be fed into data processing

More information

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO) SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY

More information

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR 1.1.0 SCOPE : This specification covers design, manufacture, testing at manufacture s works before

More information

High-Voltage GIS yesterday - today - tomorrow

High-Voltage GIS yesterday - today - tomorrow High-Voltage GIS yesterday - today - tomorrow Peter Glaubitz, Siemens AG, Principal Expert GIS-Technology siemens.at/future-of-energy Table of content GIS yesterday beginning and establishment of Gas-

More information

IEC and IEEE Standards for High-Voltage Switchgear and Controlgear Present Situation and Future Evolution

IEC and IEEE Standards for High-Voltage Switchgear and Controlgear Present Situation and Future Evolution IEC and IEEE Standards for High-Voltage Switchgear and Controlgear Present Situation and Future Evolution Denis Dufournet Chairman IEC TC 17 & SC17A Fellow IEEE Senior Expert Areva T&D Mumbai, January,

More information

DS1 Diode-based transient-free capacitor switch

DS1 Diode-based transient-free capacitor switch Medium voltage products DS1 Diode-based transient-free capacitor switch Power and productivity for a better world TM Compensation of reactive power DS1 the future of switches Compensation of reactive power

More information

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Masterclad Medium Voltage Passive Arc-Resistant Switchgear Masterclad Medium Voltage Passive Arc-Resistant Switchgear Square D Masterclad medium voltage passive arc-resistant (AR) switchgear is designed with utilities and industrial customers in mind who demand

More information

Free piston Stirling engine for rural development

Free piston Stirling engine for rural development Free piston Stirling engine for rural development R. Krasensky, Intern, Stirling development, r.krasensky@rrenergy.nl W. Rijssenbeek, Managing director, w.rijssenbeek@rrenergy.nl Abstract: This paper presents

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012

TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012 TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets 17th April 2012 Session 2 Technological challenges to cope with in TWENTIES field tests

More information

CLAMPS CONNECTORS & EQUIPOTENTIAL RING

CLAMPS CONNECTORS & EQUIPOTENTIAL RING CLAMPS CONNECTORS & EQUIPOTENTIAL RING March 2015 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata

More information

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 2 HYDRAULIC AND PNEUMATIC CYLINDERS The material needed for outcome 2 is very extensive

More information

Technical Specification for Oil insulated Transformers U m < 24 kv up to 1250 kva

Technical Specification for Oil insulated Transformers U m < 24 kv up to 1250 kva to 1250 kva Page 1/10 Technical Specification for Oil insulated Transformers U m < 24 kv up to 1250 kva This technical specification is valid for the business unit E.ON Sweden of the market unit E.ON Nordic.

More information

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge

More information

TRANSPORT OF DANGEROUS GOODS

TRANSPORT OF DANGEROUS GOODS Recommendations on the TRANSPORT OF DANGEROUS GOODS Manual of Tests and Criteria Fifth revised edition Amendment 1 UNITED NATIONS SECTION 38 38.3 Amend to read as follows: "38.3 Lithium metal and lithium

More information

26 3213.13 Diesel Engine Driven Generators Page 1 of 6

26 3213.13 Diesel Engine Driven Generators Page 1 of 6 Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at

More information

Advantages of Fixed Circuit Breaker Switchgear

Advantages of Fixed Circuit Breaker Switchgear Advantages of Fixed Circuit Breaker Switchgear by Lionel Mackay, EDF Energy, and Mike Adams, Schneider Electric Ltd Introduction The purpose of this paper is to review the advantages of fixed circuit breaker

More information

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.) TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.) 1. Requirement: Two (02) Nos. DC Type, 3 phase, 3 wire Projection Welding Machine is required for welding of ventilation M.S. / Stainless

More information

CABLE ACCESSORIES 110-220 kv

CABLE ACCESSORIES 110-220 kv CABLE ACCESSORIES 110-220 kv Termination 110 kv Technical description Termination MKB 126 / 145 with composite type insulator uses for cable line joints with other elements of power-supply systems. Termination

More information

Type K current limiting fuse canister Technical information and installation guide

Type K current limiting fuse canister Technical information and installation guide Transformer components Type K current limiting fuse canister Technical information and installation guide The Type K current limiting fuse canister provides an air-insulated receptacle for general-purpose

More information

UN Manual of Tests and Criteria, Sub-section 38.3, Amendments to the 5 th edition, effective 2014 January 1 st

UN Manual of Tests and Criteria, Sub-section 38.3, Amendments to the 5 th edition, effective 2014 January 1 st 1 UN Manual of Tests and Criteria, Sub-section 38.3, Amendments to the 5 th edition, effective 2014 January 1 st 38.3 Lithium metal and lithium ion batteries 38.3.1 Purpose This section presents the procedures

More information

Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD)

Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Note: This guidance document is a translation of official Chinese document which is issued by CQC (China Quality Certification Center) on

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under:

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under: REQUIREMENT : The equipment offered shall be highly reliable suitable to operate satisfactorily in hot humid and polluted climate. The equipments offered shall work satisfactorily within temperature range

More information

Power Capacitor Units for improved power quality

Power Capacitor Units for improved power quality Power Capacitor Units for improved power quality Applications for capacitors Reactive power compensation Most of the apparatus and loads connected to the electrical power system consume both active and

More information

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Course No: E02-010 Credit: 2 PDH Boris Shvartsberg, Ph.D., P.E., P.M.P. Continuing Education

More information

ABB Fuses Competitive Advantages

ABB Fuses Competitive Advantages GPMM Tomasz Komalski 2009 ABB Fuses Competitive Advantages May 14, 2009 Slide 1 Basic comments ABB is a global manufacturer of both current limiting and expulsion (non-current limiting) fuses for medium

More information

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX

Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX Class 6065 Instruction Bulletin 6065-13 11/2011 Retain for future use. Hazard Categories and Special Symbols Read these instructions carefully and look

More information

Instrument Transformers Application Guide

Instrument Transformers Application Guide Instrument Transformers Application Guide Edited by ABB AB High Voltage Products Department: Marketing & Sales Text: Knut Sjövall, ABB Layout, 3D and images: Mats Findell, ABB SE-771 80 LUDVIKA, Sweden

More information

Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125

Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125 Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC3-12 MC3-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated

More information

Low Voltage Switchboards The Best Technical Solution for Your Ship

Low Voltage Switchboards The Best Technical Solution for Your Ship The Best Technical Solution for Your Ship Wärtsilä SAM Electronics Optimal Power Distribution The uninterrupted supply of power to systems and consumers onboard modern ships is an extremly important matter.

More information

Protection from Short-circuit

Protection from Short-circuit Protection from Short-circuit Back-up Fuse-Link with ÜLA (controlled power dissipation) Test device for tripping device Special version with threat High-voltage Fuse-Link for voltage transformers (HSW)

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations 12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling

More information

22 kv OUT DOOR VACUUM CIRCUIT BREAKER

22 kv OUT DOOR VACUUM CIRCUIT BREAKER GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATION FOR 22 kv OUT DOOR VACUUM CIRCUIT BREAKER Getco/Engg/TechSpec/22kV/O/D VCB/R1/Nov07

More information

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force

More information

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals

More information

From 72.5 kv up to 800 kv. High-Voltage Circuit Breakers. www.siemens.com/energy

From 72.5 kv up to 800 kv. High-Voltage Circuit Breakers. www.siemens.com/energy From 7. up to 800 High-Voltage Circuit Breakers www.siemens.com/energy Germany Content 7 7 Russia India China USA Mexico Brazil Foreword 0 Modular design 0 Control 07 Quenching principles 08 Drive systems

More information