CABLE ACCESSORIES kv

Size: px
Start display at page:

Download "CABLE ACCESSORIES 110-220 kv"

Transcription

1 CABLE ACCESSORIES kv

2 Termination 110 kv Technical description Termination MKB 126 / 145 with composite type insulator uses for cable line joints with other elements of power-supply systems. Termination MKV 126 /145 is used for outdoor and inner installation, for XLPE cables 64/110 kv with the conductor cross-section Basic components Insulator composite type insulator with glass fiber reinforced epoxy resin tube and silicon rubber alter-nating sheds color light gray top and bottom flanges glued and sealed to the composite insulator Description Maximum operated voltage, Um Maximum cable insulated diameter Maximum cable sheath diameter Cable conductor cross section range Maximum allowed inclination,angle Termination length, L Creepage distance length Pollution level in accordance with IEC 60137; All Union State standard ; Electrical installation codefkb Volume of pack compaund Weight Maximum allowed force on top connector kv 2 l kg kn MKV 126 / III IV IV ,5 3,5 3,5 Cable end pre-moulded and factory-tested silicon stress cone cable end base plate branch pipe with flange support insulators seals and fixing materials unpressurised synthetic oil as an insulating medium optic fiber outlet for the connection to the equipment Area of application Type MKV 126 / 145 Maximum system voltage, kv 126 / 145 Cable conductor cross section range, Maximum cable sheath diameter, 115 Maximum cable insulation diameter, 94 Demands to the electrical parameters: AC voltage withstand test: Partial discharge test: Impulse voltage (10+/10- impulses) Environmental characteristics: Climatic category: Nominal operating current: limited by cable specification 160 kv for 30 min / 190 kv for 30 min 5 pc at 96 kv / 5 pc at 114 kv 550 kv / 650 kv YUHL1 Stress cone routine tests for MKB 126 / MKB 145 Test voltage level: 160 kv for 30 min / 190 kv for 30 min Partial discharges level: <5pC at 96 kv / <5pC at 114 kv Support insulator withstand voltages: AC voltage: 10 kv DC voltage: 20 kv Mechanical characteristics: Maximum allowed inclination with vertical: 30 C Approximate weight, kg: 115 Maximum allowed force on top connector, H (horizontal): 3500

3 Additiory Cable clamps To fix the cable before the termination and joints, we need the BKK cable clamps with the rubber inserts (PST-80), which exclude the cable longitudinal movement. Type BBK L l h d 65/ / / Joints 110 kv Technical description The pre-moulded outdoor joint MSV 126 / 145 is designed to connect two extruded high voltage cables XLPE 64/110 kv. Joint MSV 126 / 145 could be produced in different ways which admitted the possibility of screen wires direct connection, cross-bonding connection of different cable phase wires screen (screen transposition), wires screen connection with optical fibers in the metal tubes. Basic components Insulator Silicon pre-moulded joint body with elements for electrical field control Connector and sealing materials One piece pre-moulded silicone insulator Special tapes for different purposes Protective covering from shrinkable tubes and sleeves (optionally it is possible to order other protective covering) Contact clamps To connect terminations to the networks, we need to apply contact clamps. Arkasil SK supplies aluminum, bronze and bimetallic contact clamps. Area of application Type MSV 126 / 145 Maximum system voltage, kv 126 / 145 Cable conductor cross section range, ² Maximum cable sheath diameter, 115 Maximum cable insulation diameter, 91 Technical data Splice box It is applied for connection of fiber-optical modules installed in the high-voltage cables screens. Splice box is a protective metal tray, safety class IP66, with 4 inputs for fiber-optical modules, 2,5-5,5 in diameter. It protects the connection point and is applied to store the fiber stock necessary for repair or preventive works. Demands to the electrical parameters: AC voltage withstand test: 160 kv for 30 min. / 190 kv for 30 min. Partial discharge test: <5 pc at 96 kv / <5 pc at 114 kv Impulse voltage (10+/10- impulses) 650 kv Environmental characteristics: Climatic category Currency load rating: Rated operational current: Short circuit current: limited by cable specification limited by cable specification YUHL1

4 Stress cone routine tests: Test voltage level: Partial discharges level: Support insulator withstand voltages AC voltage: DC voltage: 160 kv for 30 min / 190 kv for 30 min <5pC at 96 kv / <5 pc at 114 kv 10 kv within 1 min 20 kv within 1 min Mechanical characteristics: Approximate weight, kg: 35 Joints overall dimensions MSV 126 / 145 Installation and Supervision service Arkasil SK renders services on installation and supervision of own high-voltage cable accessories. Our installation supervision services for the cable ac-cessories shall mean: Multipurpose and process supervision. The works quality control of the personnel trained in Arkasil SK to installed cable accessories and who have special certificates. Guarantee documentation on the installed Arkasil SK cable accessories. The Arkasil SK cable accessories related consultations. " Installation Supervision" in the construction standards is not defined yet. Therefore, when making an agreement, it is necessary to be governed by the normative documents, including The Regulations For Installation/ Supervision, governing the bases for granting consulting services and the contractual relations, in general. Our service on cable accessories installation shall include: Joints overall dimensions MSV 126 X / 145 X - Installation of the Arkasil SK cable accessories by the specialists certified by Arkasil SK for these works. - Guarantee documentation on the installed Arkasil SK cable accessories. - The Arkasil SK cable accessories related consultations. For more information on the installation and supervision provided by Arkasil SK, please call: +7 (495) Additionary Joint Splice box It is applied for connection of fiber-optical modules installed in the high-voltage cables screens. A joint splice box is a protective rubber base with slots and channels for the optical fibers, it provides connection of the modules, protects the connection point. It is fixed during the joint installation. The supply complete set includes all necessary accessories for the optical modules welding. Installation Training Arkasil SK arranges training for the installation contractor specialists. The training is arranged at the training center located at the Arkasil SK production facilities. There, for optimization of the educational process, Arkasil SK renders the training service at the installation contractor production facilities. The training shall include: Theory training Practical training Tests Sample preparation for certification Granting certificates By the results of examinations, the installation contractor specialists shall receive the permits for performance of installation works with the Arkasil SK cable accessories.

5 Tools for Arkasil SK cable accessories installation Installation Tool Kits 1010 Kit ( The installation tools including all necessary items for the highvoltage ca-ble and cable accessories preparation and installation) Unicut 30 Universal Cable Machine (For removal of the semi-conducting screen and insulation from the high-voltage cables, the diameter over insulation) Unicut 40 Universal Cable Machine (For removal of the semi-conducting screen and insulation from the high-voltage cables, the diameter over insulation) 1000 kg Belt Winch. (For pulling the silicon insulator on the cable) Cable Heating Kit 1080 Kit (For the high-voltage cable heating. In addition, the kit shall include the temperature setting and controlling instruments) Winch-to-Cable Fixing Device (The device is fixed on the cable, and has terminals for fixing the winches) Other Auxiliary and Installation Tools Arkasil SK Contacts: , Russia, Moscow, Zolotorozhskiy Val 32, bld.10 Тel./Fax: web-site:

6

CABLE ACCESSORIES kv

CABLE ACCESSORIES kv CABLE ACCESSORIES 110-220 kv Introduction Long terms of cable accessories delivery very often are a big problem for cable lines establishing. That is why there is a great demand of cable accessories for

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities

HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities RELY ON OUR EXPERIENCE... EXPERIENCE OUR CAPABILITIES For close to half a century, Silec

More information

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003 MiCAFIL 1 RIP Technology Z. Zic 09/2003 )XQFWLRQRI+LJK9ROWDJH%XVKLQJ Uncontrolled (natural) electrical field Capacity-controlled electrical field %XVKLQJV0DLQ,QVXODWLRQ6\VWHPV 7\SH 0DLQ,QVXODWLRQ +RXVLQJFRYHU

More information

ACCESSORIES FOR HV CABLES WITH EXTRUDED INSULATION

ACCESSORIES FOR HV CABLES WITH EXTRUDED INSULATION ACCESSORIES FOR HV CABLES WITH EXTRUDED INSULATION Ref: WG 21.06 (TB 177) JTF 21.15 (TB 210) TF B1.10 (Electra 212) Henk Geene Presentation overview Accessories function Accessory design Accessory types

More information

NEXANS POWER ACCESSORIES

NEXANS POWER ACCESSORIES Catalogue 0 NEXANS POWER ACCESSORIES Nexans Power Accessories Nexans is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy

More information

Analytical Report RF high voltage cable accessories market

Analytical Report RF high voltage cable accessories market Analytical Report RF high voltage cable accessories market High voltage cable accessory market of Russia, development trends Cable accessories are special devices aimed to connect cables mechanically and

More information

Earthing Kits. 3M AC Series - Armour Continuity Kits. Electrical Tapes. Low Voltage Joints & Terminations. Cold Shrink tubes & End Caps.

Earthing Kits. 3M AC Series - Armour Continuity Kits. Electrical Tapes. Low Voltage Joints & Terminations. Cold Shrink tubes & End Caps. Earthing Kits 45 Resins 3M AC Series - Armour Continuity Kits This Scotchcast Armour Continuity Kit is designed to provide complete electrical continuity across the joint position on 2, 3 or 4 core armoured

More information

EDITION 2012 CABLE SYSTEMS

EDITION 2012 CABLE SYSTEMS EDITION 2012 CABLE SYSTEMS Cable fittings for high voltage networks Welcome to the CABLE SYSTEMS Centre of Competence. Our range of cable accessories offers solutions for virtually all applications in

More information

HV SYSTEMS. Prysmian HV Systems Product Range 66kV & 132 kv

HV SYSTEMS. Prysmian HV Systems Product Range 66kV & 132 kv HV SYSTEMS Prysmian HV Systems Product Range 66kV & 132 kv Prysmian HV Product Range Version: 06/10 The History of Cables 66kV Copper Conductor XLPE Insulated Cables Prysmian Cables & Systmes Ltd is part

More information

UGVCL/SP/591/11KV HT AB CABLE

UGVCL/SP/591/11KV HT AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched

More information

KNOW YOUR OPTIONS: 230 KV POWER CABLES

KNOW YOUR OPTIONS: 230 KV POWER CABLES KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common

More information

INNER CONE CONNECTORS Type CPI, SPI and FPI

INNER CONE CONNECTORS Type CPI, SPI and FPI INNER CONE CONNECTORS Type CPI, SPI and FPI Completing the picture nkt cables GmbH 999 NKT A/S, Denmark, merged with Felten & Guilleaume Kabelwerke GmbH in Germany to form nkt cables group GmbH with headquarters

More information

1ZSC000563-AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

1ZSC000563-AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide 1ZSC000563-AAC en, Rev. 7 Resin impregnated paper bushing, oil to air, type GSB Technical guide Original instruction The information provided in this document is intended to be general and does not cover

More information

MEDIUM VOLTAGE SURGE ARRESTERS

MEDIUM VOLTAGE SURGE ARRESTERS 011: 2008 CEB SPECIFICATION MEDIUM VOLTAGE SURGE ARRESTERS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MEDIUM VOLTAGE SURGE ARRESTERS CEB Specification - 011: 2008 CEYLON ELECTRICITY BOARD No.

More information

Section 5 161 kv Power Cables

Section 5 161 kv Power Cables Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper

More information

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both

More information

a Nexans company Catalogue 2014

a Nexans company Catalogue 2014 a Nexans company Catalogue 2014 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated

More information

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials VDE Information General Information The voltage which can be applied to a terminal depends on the relevant regulations, the installation conditions and, of course, the dimensions and insulating materials

More information

1ZSE 2750-105 en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

1ZSE 2750-105 en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide 1ZSE 2750-105 en, Rev. 8 Transformer bushings, type GOE and GOE(2) Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible

More information

NT Cast Resin Post Insulators and Busbar Clamps. Catalogue. Catalogue NT 1 GB Medium Voltage. ABB Transmit 1 NT 1 GB

NT Cast Resin Post Insulators and Busbar Clamps. Catalogue. Catalogue NT 1 GB Medium Voltage. ABB Transmit 1 NT 1 GB Catalogue NT Cast Resin Post Insulators and Busbar Clamps Catalogue 96-09 Medium Voltage ABB Transmit 1 NT Cast Resin Post Insulators and Busbar Clamps Index Description... Selection table for: Indoor

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables

More information

Transformer Bushings for GIS

Transformer Bushings for GIS Transformer Bushings for GIS Oil to SF6 Connections GARIP RTKG 725-55 kv SQS certified ISO 91 / ISO 141 Bushings RIP - Technology for SF6 / Oil - Bushings In modern metal enclosed switchgear SF6 -gas is

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

SECTION 16461 DRY-TYPE TRANSFORMERS

SECTION 16461 DRY-TYPE TRANSFORMERS SECTION 16461 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Furnishing and installation of and testing of cast resin dry type MV/LV distribution transformer in accordance with specifications and drawings. Any

More information

Fiber Optics Current Sensor Free Standing Enabling smart grids and digital substations

Fiber Optics Current Sensor Free Standing Enabling smart grids and digital substations Fiber Optics Current Sensor Free Standing Enabling smart grids and digital substations Content ABB Global Technology Leader ABB HV Products Portfolio Instrument Transformers ABB HV Products Portfolio Current

More information

Medium voltage insulator

Medium voltage insulator Medium voltage insulator Line post insulators type R-ET Commercial designation LPI 24 N ET 1) LPI 24 L ET/5 1)2) LPI 24 L ET/6 1)2) LPI 38 L ET 1) esignation acc. to IEC 720 R 12,5 ET 125 N R 12,5 ET 125

More information

No Heat. No Flames. No Shoving. No Special Tools. 3M Cold Shrink. 3M Cold Shrink. Medium Voltage Joints & Terminations. 3M Cold Shrink Joint

No Heat. No Flames. No Shoving. No Special Tools. 3M Cold Shrink. 3M Cold Shrink. Medium Voltage Joints & Terminations. 3M Cold Shrink Joint M Cold Shrink Medium Voltage Joints & Terminations M Cold Shrink Joint Splice bodies 00% factory tested - ensures reliability Capacitive Stress Relief No Heat No Flames No Special Tools No Shoving Unique

More information

Medium Voltage Joints & Terminations

Medium Voltage Joints & Terminations Medium Voltage Joints & Terminations 59 Medium Voltage - Cold Shrink Joints Supporting Core Radially shinkable elastomeric splice Semi-conductive layer High permitivity insulation layer Semi-conductive

More information

Lugs and Connectors. Lugs and Connectors. PHONE:

Lugs and Connectors. Lugs and Connectors. PHONE: 3M Scotchlok are crimp connectors for power cable conductors. These connectors are used when splicing and terminating power cable. 3M Scotchlok Connectors 000 and 100 Series and Lugs 30000 and 300 Series

More information

Single-core power cable. 18/30 (36) kv Conductor material 1x630 mm 2 Insulation material. HES HACILAR ELEKTRİK SAN. VE TİC. A.Ş.

Single-core power cable. 18/30 (36) kv Conductor material 1x630 mm 2 Insulation material. HES HACILAR ELEKTRİK SAN. VE TİC. A.Ş. TIC 1066-12 TYPE TEST CERTIFICATE OF COMPLETE TYPE TESTSS OBJECT TYPE Single-core power cable N2XSYR(A)Y Rated voltage, U 0/U (U m) Conductor cross-section 18/30 (36) kv Conductor material 1x630 mm 2 Insulation

More information

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR

More information

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED

More information

Raychem High Voltage Cable Accessories up to 170 kv

Raychem High Voltage Cable Accessories up to 170 kv Raychem High Voltage Cable Accessories up to 170 kv Content About TE Energy High Voltage Products Page 4 About TE Energy High Voltage Cable Accessories Page 6 Raychem Outdoor Terminations OHVT-C (Composite)

More information

HV glass suspension insulator U70BS and U70BL type Ball and socket type Standard profile

HV glass suspension insulator U70BS and U70BL type Ball and socket type Standard profile U70BS and U70BL type IEC 60305 U70BS U70BL GOST 27661 ПС70Е ПС70Е Minimum mechanical failing load kn 70 70 Minimum mechanical residual strength kn 56 56 Diameter of the insulating part, D mm 255 255 Nominal

More information

Gulf Cable & Electrical Ind. Co.

Gulf Cable & Electrical Ind. Co. CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC

More information

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13 Cable Accessories for Extruded Dielectric Cable 69kV - 230kV Rated Components used in cable systems 100% Tested Factory Molded For outdoor applications through 230kV For gas insulated substations and transformers

More information

Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1

Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1 Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

08. SEK IDC CONNECTORS

08. SEK IDC CONNECTORS . IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these

More information

Development of 22-kV XLPE Cable and Joint with Reduced Insulation Thickness Having Water-Impervious Aluminum Layer

Development of 22-kV XLPE Cable and Joint with Reduced Insulation Thickness Having Water-Impervious Aluminum Layer Development of 22-kV XLPE Cable and Joint with Reduced Insulation Thickness Having Water-Impervious Aluminum Layer by Hiroyuki Mabuchi *, Satoru Koizumi *, Haruki Nozawa *, Yoshihiro Maeda * 2, Hideo Kawahara

More information

SB 175 Connectors - up to 280 Amps

SB 175 Connectors - up to 280 Amps Connectors - up to 280 Amps 2 Pole Wires sizes from #12 (3.3 mm²) to 1/0 (50 mm²) fit in the second to largest connector in the SB series. The 3 pole adds an additional position for power or grounding.

More information

Transformer Bushings Type COT

Transformer Bushings Type COT Transformer Bushings Transformer Type COT Bushings... COT 050 Type COT...050 kv to 5 kv up kvto to 5 kv A up IEC to 37 A IEC 37 E 3.8 Features If you need any transformer bushing proven in operation conditions

More information

A Study of a MV Cable Joint

A Study of a MV Cable Joint SERBIAN JOURNAL OF ELECTRICAL ENGINEERING Vol. 7, No. 1, May 2010, 1-11 UDK: 621.315.35:537.212 A Study of a MV Cable Joint Radiša Dimitrijević 1, Neda Pekarić-Nađ 2, Miodrag Milutinov 3 Abstract: Construction

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

600 A 15 kv class BT-TAP deadbreak connector

600 A 15 kv class BT-TAP deadbreak connector Deadbreak Connectors Catalog Data CA650002EN Supersedes January 2015 600 A 15 kv class BT-TAP deadbreak connector COOPER POWER SERIES General Eaton terminates high-voltage underground cable to transformers,

More information

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400 > As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life

More information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and

More information

USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black

USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black USB.0 CableS USB.0 and backwards compatible for USB.0 and. Supports high speed, 480Mbps Twisted-pair construction reduces cross talk to ensure error free transfer USB A male to USB B male 00-0 007-0 0-09-

More information

SECTION 271525 OPTICAL FIBER CABLES AND ACCESSORIES. A. Interior Raceways, Fittings, and Accessories: Section 260532.

SECTION 271525 OPTICAL FIBER CABLES AND ACCESSORIES. A. Interior Raceways, Fittings, and Accessories: Section 260532. SECTION 271525 OPTICAL FIBER CABLES AND ACCESSORIES PART 1 GENERAL 1.01 RELATED WORK SPECIFIED ELSEWHERE A. Interior Raceways, Fittings, and Accessories: Section 260532. B. Wiring, General - 600 Volts

More information

SIMPLE WIRE-PRESS CONNECTORS (AXF1, 2)

SIMPLE WIRE-PRESS CONNECTORS (AXF1, 2) SIMPLE WIRE-PRESS CONNECTORS SIMPLE WIRE-PRESS CONNECTORS (Compliant with e-con) New Wire connection plug 2. The structure is designed to temporarily hold inserted wires before crimping, allowing for high

More information

Termination. Termination Kits & Joints

Termination. Termination Kits & Joints Termination Termination Kits & Joints Termination Kits Insulating Boots Cable Box Glands Earthing Kits Cable Joints End Caps Cable Breakouts Bus Bar Tubing Bus Bar Tapes Insulating & Sealing Tubing Splicing

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 01 A1 08 02 A2 A4 05 A5 external rubber gasket external rubber gasket external rubber gasket external rubber gasket external rubber gasket 21 25 4 69 5 stainless

More information

1 FOSC cover 1 piece Protecting fiber cable splices in whole 2 FOSC bottom 1 piece Fixing reinforced core, fiber cable

1 FOSC cover 1 piece Protecting fiber cable splices in whole 2 FOSC bottom 1 piece Fixing reinforced core, fiber cable TS-GPJ02VM 1. Scope of application This Installation Manual suits for the Fiber Optic Splice Closure (Hereafter abbreviated as FOSC), as the guidance of proper installation. The scope of application is:

More information

R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES

R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES IEC SYSTEM FO CONFOMITY TESTING AND CETIFICATION OF ELECTICAL EQUIPMENT COMMITTEE OF TESTING LABOATOIES TESTING AND MEASUING EQUIPMENT/ALLOWED SUBCONTACTING Power cables with extruded insulation and their

More information

Transmission Silicone Insulators Line Post 69 kv to 161 kv

Transmission Silicone Insulators Line Post 69 kv to 161 kv K-LINE INSULATORS LIMITED Catalogue T-LP Transmission Silicone Insulators Line Post 69 kv to 161 kv ISO9001 SAI GLOBAL FILE No. 000117 Transmission Silicone Insulators Line Post Today transmission lines

More information

High Voltage Cable Systems

High Voltage Cable Systems High Voltage Cable Systems Cables and Accessories up to 550 kv Completing the picture nkt cables part of a world, counting on reliable and available electrical power Today a world without electrical power

More information

Premolded cable termination, indoors SOT 7.2 kv

Premolded cable termination, indoors SOT 7.2 kv Premolded cable termination, indoors SOT 7. kv cables 1- or 3-core with Al or Cu conductor for 6.6/7. kv, indoors. t can also be installed in an indoor humid environment*. s CENELEC, HD 69.1 S1 integrated

More information

Reliable Solutions for Electrified Railway Systems

Reliable Solutions for Electrified Railway Systems Reliable Solutions for Electrified Railway Systems 1 2 3 4 Insulation Enhancement System 1. Raychem MVLC (Medium Voltage Line Cover) Provides insulation for catenary, droppers and associated conductors

More information

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES THE PATHWAY TO POWER HIGH-VOLTAGE CABLES TABLE OF CONTENTS HIGH-VOLTAGE CABLES 3 Advantages of XLPE-insulated cable systems 3 PROPOSAL 4 Cable systems 4 Providing System Solutions 4 Continuous temperature

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

High Voltage Systems. Today. The history of cables

High Voltage Systems. Today. The history of cables High Voltage Cables High Voltage Systems Today Prysmian Cables and Systems B.V. is part of the Prysmian Group, a leading player in the industry of high-technology cables and systems for energy and telecommunications,

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief

More information

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW Complete One Stop Solution for OPGW Cable and Fittings for OPGW 53, Justice Chandra Madhav Road, Kolkata - 700020. India. Phone: 91-33-24748575 / 7565 Fax: 91-33-2476-1955 Email: sales@supremeco.com Website:

More information

Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD)

Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Note: This guidance document is a translation of official Chinese document which is issued by CQC (China Quality Certification Center) on

More information

VIPERFLEX ELECTRIC CABLE

VIPERFLEX ELECTRIC CABLE VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07

More information

EDS 02-0027 11KV TRIPLEX CABLE

EDS 02-0027 11KV TRIPLEX CABLE THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: EDS 02-0027 ENGINEERING DESIGN STANDARD EDS 02-0027 11KV TRIPLEX CABLE Network(s): EPN, LPN, SPN Summary:

More information

PT 2-PE/S-120AC/FM. Extract from the online catalog. Order No.:

PT 2-PE/S-120AC/FM. Extract from the online catalog. Order No.: Extract from the online catalog PT 2-PE/S-120AC/FM Order No.: 2856812 The figure shows the PT 2-PE/S-230AC/FM version DIN rail module with pluggable surge protection type 3 for terminal equipment, fault

More information

For More Information Visit 3M Electrical Lugs and Connectors Pages

For More Information Visit 3M Electrical Lugs and Connectors Pages For More Information Visit 3M Electrical Lugs and Connectors Pages http://solutions.3m.com/wps/portal/3m/en_us/emdci/home/s/lugsandconnectors/ Lugs and Connectors Copper Connectors 149 Copper/Aluminum

More information

Dry type transformers with air insulated MV windings

Dry type transformers with air insulated MV windings E N G L I S H Dry type transformers with air insulated MV windings TTR TTO OTN, OTR, OTF reactors TTH Technology Magnetic Core The core is made of grain oriented magnetic sheets characterized by high permeability

More information

OLI. Oil level indicator

OLI. Oil level indicator OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap

More information

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

The Contractor shall furnish and install all shielded power cable suitable for use on this project. Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS

More information

6-36kV Medium Voltage Underground Power Cables. XLPE insulated cables

6-36kV Medium Voltage Underground Power Cables. XLPE insulated cables 6-36kV Medium Voltage Underground Power Cables XLPE insulated cables Cable solutions to ensure the reliability of your energy network 2 With energy as the basis of its development, Nexans, the worldwide

More information

PC 4/ 4-ST-7,62. Extract from the online catalog. Order No.: 1804920

PC 4/ 4-ST-7,62. Extract from the online catalog. Order No.: 1804920 Extract from the online catalog PC 4/ 4-ST-7,62 Order No.: 1804920 The figure shows a 5-pos. version of the product Plug component, nominal current:, rated voltage: 400 V, pitch: 7.62 mm, no. of positions:

More information

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks Introduction This document presents the fundamental aspects of cable and conductor selection for connecting pad mounted shunt

More information

NSW OFFSHORE AND SPECIAL CABLES. Cables for the future, delivered today.

NSW OFFSHORE AND SPECIAL CABLES. Cables for the future, delivered today. NSW OFFSHORE AND SPECIAL CABLES. Cables for the future, delivered today. NORDDEUTSCHE SEEKABELWERKE GMBH (NSW) The submarine competence center within the General Cable Group NSW was founded in 1899 by

More information

Medium-Voltage. Power cable installation throughout Europe and the UK until the early. Cable Accessories. Special Feature

Medium-Voltage. Power cable installation throughout Europe and the UK until the early. Cable Accessories. Special Feature Special Feature Medium-Voltage Cable Accessories Power cable installation throughout Europe and the UK until the early 60s exclusively used impregnated paper for the primary insulation of the conductors

More information

E2K-L. Liquid Level Sensor. Applications. Ordering Information

E2K-L. Liquid Level Sensor. Applications. Ordering Information Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

Fault location on power cables. Fault location on power cables

Fault location on power cables. Fault location on power cables Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables

More information

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS DESCRIPTION The HASK-P Hazardous Area Seal Kit provides the cable termination and explosion proof seal parts needed to make the power end electrical connections associated with Nelson Heat Tracing Systems

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60669-1 Edition 3.1 2000-03 Edition 3:1998 consolidated with amendment 1:1999 Switches for household and similar fixed-electrical installations Part 1: General requirements IEC

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS (PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS IS 12729:2004 IEC 60694(2002) 1.1 Scope This International Standard applies to a.c. switchgear and controlgear,

More information

Rubber Lining Application Manual Revision Date: September 1, 2009. Section 10: Pipe Lining Procedures Page: 10-1

Rubber Lining Application Manual Revision Date: September 1, 2009. Section 10: Pipe Lining Procedures Page: 10-1 Section 10: Pipe Lining Procedures Page: 10-1 GENERAL PROCEDURE FOR APPLYING RUBBER LINING TO PIPE 1. METAL SPECIFICATION Pipe should be fabricated in accordance with requirements found in RMA Bulletin

More information

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

ACCESSORIES FOR XLPE-INSULATED HIGH AND EXTRA-HIGH VOLTAGE CABLES

ACCESSORIES FOR XLPE-INSULATED HIGH AND EXTRA-HIGH VOLTAGE CABLES ACCESSORIES ACCESSORIES FOR XLPEINSULATED HIGH AND EXTRAHIGH VOLTAGE CABLES Cable Systems, Cables and Accessories THE POWER OF INNOVATION: A TRADITION OF THINKING OUTSIDE THE BOX Contents Welcome to Südkabel

More information

Fiberoptic Cable Testing Methods

Fiberoptic Cable Testing Methods Fiberoptic Cable Testing Methods Per IEC 60794-1-2 Synergy Cables Quality Assurance Department Written by Dr. Hanan Yinnon July 2007 Page 1 1. Tensile performance Per IEC-794-1-2 Method E1 1.1. Object

More information

3-Component Measuring System

3-Component Measuring System Force 3-omponent Measuring System for utting Force Measurement During Turning Modular system for measurement of cutting forces when turning outside and inside diameters on turret lathes. Machine adapters

More information

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp Page 1 2015 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable Grounded Metal

More information

Wall Mounted Products

Wall Mounted Products Metallic Indoor PK Termination Boxes Prysmian Part Numbers: see below Metallic PK Termination Boxes are designed for the termination, branching and distribution of fibre optic cables in telecommunication,

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

n Choice of equipment SP 58 Index of protection: IP 2X - IP 2XC - under front plate

n Choice of equipment SP 58 Index of protection: IP 2X - IP 2XC - under front plate SP fuse carriers with protected terminals SP fuse carriers with protected terminals www.klinkmann.com n Choice of equipment Maximum cartridge rating Type Rated current 400 V± 0 V± 690 V± gg am gg am gg

More information

Network Standard Advice No. 1420C 9/6/2011

Network Standard Advice No. 1420C 9/6/2011 Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides

More information

Type XPI-III Surge Arresters Maximum System Voltage 2 to 48 kv

Type XPI-III Surge Arresters Maximum System Voltage 2 to 48 kv Type XPI-III Surge Arresters Maximum System Voltage 2 to 48 kv XPI-III Metal Oxide Surge Arrester XPI-III Metal Oxide Surge Arresters are for protection of switchgear, transformers, and other equipment

More information

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo Connectors, Clamps, Compensating Devices, Insulators and Safety Equipment for Overhead Catenary Lines RAILWAY CATENARY SYSTEMS Components and Systems for the Electrification of Railway Lines. Welcome to

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle s 4 502 ACVATIX Electromotoric rotary actuators for butterfly or slipper valves SAL.. with 90 rotary angle SAL31.. Operating voltage AC 230 V, 3-position control signal SAL61.. Operating voltage AC/DC

More information

Bushing Selection Making the Right Choice By: Keith P Ellis Trench Limited

Bushing Selection Making the Right Choice By: Keith P Ellis Trench Limited Bushing Selection Making the Right Choice By: Keith P Ellis Trench Limited Abstract: -- Bushings are a critical component for liquid filled power transformers and reactors. Bushing selection is a complex

More information

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for

More information