TRAINING SERVICES. DEVELOPING TALENT and MINIMIZING RISK.
|
|
- Vivien Mosley
- 7 years ago
- Views:
Transcription
1 TRAINING SERVICES DEVELOPING TALENT and MINIMIZING RISK.
2
3 OCS Group has added to its training offerings: Mechanical CompEx CompEx ExF (Foundation) Behavior Based Safety OCS Group has increased the number of additional CompEx01-04 courses to support industry demands. (See Training Course Calendar Insert) OCS Group continues to develop courses for our clients, tailored to meet their specified training needs. In fact, just over the past year, we completed custom training classes, nationally and for Bureau of Safety and Environmental Enforcement (BSEE).
4 This five-day course provides candidates with understanding of the terminology and protection concepts for electrical/instrument equipment utilized in explosive atmospheres. It covers the IEC Standard Parts 14 and 17 and ATEX 95 and 137 European Directives, including the preparation, installation, inspection and maintenance of electrical/instrument equipment used in explosive atmospheres. The course utilizes both practical and theoretical assessments, covering all protection concepts listed in order to validate a candidate s core competency to work safely in explosive atmospheres in a series of specific modules listed below: EX01: The preparation and installation of Ex d, n, e and p electrical equipment EX02: The inspection and maintenance of Ex d, n, e and p electrical equipment EX03: The preparation and installation of Ex i equipment and systems EX04: The inspection and maintenance of Ex i equipment and systems In this two-day class, students will review updated requirements for the installation of electrical apparatus for use in hazardous areas. The first day concentrates on current directives and practices. On the second day, delegates are assessed in maintenance, installation and inspection. Topics include: Sources of ignition Nature of hazards and identification of hazards Area classifications zones 0, 1 and 2 Selection of apparatus, cabling, glanding and termination Inspection and testing Management and remedial work This three-day course is designed to develop the competency of mechanical personnel working in potentially flammable atmospheres. Delegates gain knowledge, understanding and practice in the preparation, installation, inspection and maintenance of mechanical equipment. The class also covers the standards for the manufacture and installation of mechanical equipment and their protection concepts. Topics include: Maintaining hazardous area equipment Protection concepts Standards, best practice and company criteria Sources of ignition Area classification and zones Hydraulic hose assembly Terminology and definitions
5 This This CompEx training unit unit is is designed to give to give a full a full under under This CompEx training unit is designed to give a full understanding of the requirements of working safely in a potentially explosive atmosphere through knowledge based training and assessment. Targeted specifically at CompEx core competency and the promotion of safe working, this course aims to raise awareness of the management responsibility and actions where management has control of/or directs work of personnel who carry out the installations and maintenance of electrical equipment and apparatus in hazardous environments. Topics include: Equipment Directive & EPS Regulations and Worker Directives Ignition Sources Flammables Characteristics of gases and vapours (IEC ) Characteristics of dusts (IEC ) Area Classifications Boundary Signage Categories & EPLs (IEC ) Equipment for use in Hazardous Areas This This four-day course course enhances knowledge of industry of industry standards (outlined by gove by government and industry This four-day course enhances knowledge of industry standards (outlined by government and industry bodies) and provides the most effective practice for the manufacture, installation and maintenance of bodies) and provides the most effective practice for the manufacture, installation and maintenance of electrical/instrument equipment and the protection concepts utilized within hazardous areas. Delegates electrical/instrument that complete and pass equipment the course and receive the protection an IADC-validated concepts competency utilized within certificate. hazardous Topics areas. include: Delegates that complete and pass the course receive an IADC-validated competency certificate. Topics include: Overview of area classifications, gas groups and temperature classes Overview Equipment of area protection classifications, concepts gas groups and temperature classes Equipment Selection protection of apparatus, concepts cabling, gland and termination requirements Selection Inspection of apparatus, of equipment cabling, and systems gland and to IEC termination , requirements API and NEC Standards Inspection Testing of of installation equipment and systems to IEC , API and NEC Standards Testing Management of installation and remedial work Management Brief overview and of remedial the ATEX work Directives Brief overview of the ATEX Directives
6 This This four-day four-day course course is designed is designed to instruct to instruct electrical electrical personnel in the in the sa sa This four-day course is designed to instruct electrical personnel in the safe working techniques for offshore and onshore industrial high voltage applications. It covers the IEC and NEC standards for HV switching, electrical isolations and flash protection boundaries per the NFPA 70E Our new power generation and distribution simulator instructs technicians in the start-up and troubleshooting of of offshore power systems and and allows our our instructors to cover the following topics: NFPA-70E Electrical Safety Standards NFPA-70E Arc Flash Protection Electrical Boundaries Safety Standards appropriate PPE Arc Recommended Flash Protection practices Boundaries for isolations, and appropriate switching PPE and grounding Recommended HV terminology, practices system for component isolations, identification switching and and grounding functions HV Core terminology, electrical principles system component and concepts identification and functions Core Alternators electrical and principles voltage regulation and concepts Alternators Power system and distribution voltage regulation and dynamics (PF, KVAR, KW, KWA) Power Synchronization, system distribution load sharing and dynamics (droop), and (PF, Isochronous KVAR, KW, Generator KWA) Synchronization, Operations load sharing (droop), and Isochronous Generator Operations Distribution component-switchgear and transformers Distribution High Voltage component-switchgear cabling and electrical stress and transformers relief High Hi-Pot Voltage and IRT cabling testingand electrical stress relief Hi-Pot and IRT testing This This one-day one-day course course teaches teaches delegates about about the the techn technical aspects of lifting operations, lifting equipment (appliances This one-day and and course accessories), teaches and delegates and recommended about pract the practices/specification technical aspects of lifting of industry s operations, best lifting practice. equipment The course (appliances begins with and looking accessories), at standards and that recommended cover dropped practices/specification objects, the best method of industry s for the right best equipment, practice. The secondary course fastening begins methods with and looking how at to standards inspect safety that slings. cover dropped Topics include: objects, the best method for the right equipment, secondary fastening methods and how to inspect safety slings. Topics include: Planning a lifting operation Equipment Planning a pre-use lifting operation inspection Safety Equipment positioning pre-use inspection Dropped Safety positioning objects inspection Categorization Dropped objects of lifts inspection Lifting Categorization and inspection of lifts regulations and requirements Lifting and inspection regulations and requirements
7 Behavioral Based Safety (BBS) is an approach to safety that focuses on workers' behavior as the cause of most work-related injuries and illnesses. Statistics state that in 80 to 90 per cent of all incidents, the employee behavior was an important link. BBS focuses on identifying and reinforcing a safety culture and will give your employees the opportunity to address the critical aspects of building an incident free culture. We will focus on identifying and reinforcing safe behaviors, therefore reducing unsafe/at-risk behaviors. Students will learn through conversations, demonstrations, hands-on learning, practical exercises and discussions. They are extremely service minded personnel! Training Coordinator Maersk They worked with us to accommodate our ever-changing schedules. Offshore Training Branch Bureau of Safety and Environmental Enforcement (BSEE) Class was excellent and staff was very warm and welcoming. Thank you OCS!! S&C Surveyor - Lloyds Register One of the best courses I have been on I highly recommend OCS! Electrical Technician - Ensco They are organized and always pleasant to work with. Training Coordinator - Seadrill Everyone is pleasant to work with & always willing to help in any way they can...always going the "extra mile" for us Training Coordinator Diamond Offshore Drilling
8 To view the latest course descriptions and the 2015 Training Calendar, visit the OCS website at To schedule training, please contact the main OCS Group offices in Houston, Texas: Phone: Fax: Training Location: Park Row, Houston, TX N OCS Group W E S Park Row Park Ten Broadfield Interstate 10 State Hwy 6 Sam Houston Tollway 8 Travelling from Downtown, head west on Interstate 10 and take the State Hwy 6 / Addicks Exit. Go North on Hwy 6 until you reach the next stop light which is Park Row Blvd. Turn left on Park Row and continue going West under the overpass. The OCS offices are located at Park Row on the north (right side) on Park Row Blvd.
9 OCS Group is dedicated to efficiently providing the premier services in commissioning, inspections and technical training and to developing innovative solutions to solve our clients most complex issues within this realm of expertise. We deliver these services with an unwavering commitment to the highest safety and quality standards, evidenced by our IS certification. Services Commissioning Critical Inspections Software Development Engineering Construction Technical Training Accreditations International Association of Drilling Contractors (IADC) JTL CompEx DNV ISO 9001 Quality Management System Memberships API DROPs IMAC IADC Clients Diamond Offshore Ensco Maersk Pacific Drilling Rowan Seadrill Transocean Office Locations Houston, Texas, USA Brazil China India Singapore OCS 2015 V5
10
11
12 Park Row Houston, TX
Products Solutions Services. CompEx training From the process safety experts
Products Solutions Services CompEx training From the process safety experts 1 CompEx Training The process safety experts Endress+Hauser is a global leader in measurement instrumentation, services and solutions
More informationHazardous Locations Training
Hazardous Locations Training If you are involved with projects associated with hazardous locations, which involves the installation or inspection and maintenance of electrical or non-electrical e.g. mechanical;
More informationDemystifying arc flash hazard management
Demystifying arc flash hazard management Presented by Matt Brazier Senior Electrical Engineer Gove Operations November 2013 Standard NFPA 70E IEEE 1584 AS/NZS 4836 TERMINOLOGY Arc arc flash hazard analysis
More informationCONSULTING Training Courses
CONSULTING Training Courses 2 EXPLOLABS TRAINING MAKES THE DIFFERENCE 1. GENERAL Why training by Explolabs Consulting? For training in the specialized, high-risk field of explosion protection, one needs
More informationHazardous location. Definitions
Hazardous location Definitions hazardous location means any location, where there may be a significant risk of igniting gas, dust, mist or vapour, including the following: 1.1 For underground coal mines
More informationTerminal Box. Specifications TNCN
Terminal box The /TNCC range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main body is manufactured from minimum 1,5 mm sheet
More informationINTERNATIONAL STANDARD
IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60
More informationChoosing the Best Solution for Reducing Arc Energy
CONVENTION SESSION HANDOUT Choosing the Best Solution for Reducing Arc Energy Terry L. Schiazza, Business Development Manager Square D / Schneider Electric SESSION #11 Independent Electrical Contractors
More informationInstructions for Safe Use
Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety
More informationEX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
More informationPlug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
More informationPlug and Socket Devices SolConeX 16 A Series 8570
www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle
More informationBy: Santiago Consunji American Industrial Systems, Inc. www.aispro.com
Addressing Hazardous Areas Safety Requirements with Properly Designed Intrinsically Safe and Ex Approved HMIs and Panel PC Solutions for the Oil & Gas Industry By: Santiago Consunji American Industrial
More information50t. Product training courses. 40t
Training Courses Introduction Hi-Force, the leading UK based manufacturer of high pressure hydraulic tools, has been providing training courses in the safe and proper application, use, operation, service,
More informationPLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
More informationOCCUPATIONAL SAFETY & HEALTH ADMINISTRATION OSHA COURSE DESCRIPTIONS
OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION OSHA COURSE DESCRIPTIONS WWW.osha.gov/dte/edcenters/course_description.html Course Descriptions OSHA #500 - Trainer Course in OSHA Standards for Construction
More informationVariable speed drives for synchronous and asynchronous motors
Imptant infmation Altivar XXXXXX Variable speed drives f synchronous and asynchronous mots ATEX manual F ATEX applications in explosive gas atmosphere in the presence of combustible dust 0/010 S1A0 www.schneider-electric.com
More informationworldwide training services > SCOPES AND CONTACT... p. 488 > ELECTRICITY... p. 490 > HANDLING LIFTING HOISTING... p. 491 > FIRE SAFETY... p.
worldwide training services > SCOPES AND CONTACT... p. 488 > ELECTRICITY... p. 490 > HANDLING LIFTING HOISTING... p. 491 > FIRE SAFETY... p. 493 > RISK ASSESSMENT... p. 494 worldwide training services
More informationSafety instructions VEGADIS DIS81.CEIA/V****
Safety instructions VEGADIS DIS81.CEIA/V**** CSA 14.2662675 Ex d IIC T6 T1 Gb 0044 Document ID: 48926 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application
More informationIECEX CERTIFICATION SCHEMES VERSUS ATEX DIRECTIVES
IECEX CERTIFICATION SCHEMES VERSUS ATEX DIRECTIVES Rudolf Pommé Hendrik Jan Sijrier KEMA Quality B.V. KEMA Quality B.V. Ultrechtseweg 310 Ultrechtseweg 310 6812 AR Arnhem 6812 AR Arnhem The Netherlands
More informationSouth Central Service Center
South Central Service Center Hunter M. Sims, P.E. Senior Forensic Electrical Engineer Dallas, Texas 469-877-6121 hsims@uis-usa.com EDUCATION: Rose-Hulman Institute of Technology Terra Haute, Indiana Bachelor
More informationIMPORTANT SAFETY NOTICE
IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds
More informationTerminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
More informationUnderstanding European versus U.S. temperature code ratings for solenoidoperated. A White Paper From ASCO
Understanding European versus U.S. temperature code ratings for solenoidoperated valves by Manny Arceo A White Paper From ASCO 4 Introduction Solenoid valves are vital components of many process automation
More informationIndustrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will
More informationMidwest Healthcare Engineering Conference and Trade Show 2012 Indianapolis, Indiana
Midwest Healthcare Engineering Conference and Trade Show 2012 Indianapolis, Indiana Arc Flash Overview An engineering solutions company November 7, 2012 Agenda Introductions Arc Flash defined History and
More information2013WWOA Conference Technical Conference Program
2013WWOA Conference Technical Conference Program Understanding Arc-Flash Hazards, Its Implications on Operations and Solutions that Mitigate Such Exposure Presented by Jerry Baskin Senior Product Manager
More informationCABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified
IECEx & ATEX 95 CMP PRODUCTS S AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND Triple Certified Single Solution Three Forms of Protection Ex d / Ex e / Ex nr N O O T H E R M A CONTENTS Leading
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
More informationCertified HVAC - Refrigeration Training Program
FINAL CERTIFICATION AWARDED BY IMRTC - USA Certified HVAC - Refrigeration Training Program This highly specialized and concentrated Program is ideally suited to following individuals who: A people who
More informationBRAZILIAN CERTIFICATION SYSTEM
BRAZILIAN CERTIFICATION SYSTEM By: Giovanni Hummel (IEx) and Denise Ferreira (UL do Brasil) BRAZIL has a new Regulation www.iexcert.com.br Page 1 GENERAL INFORMATION November, 2008 - Brazil submits the
More informationRosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction
Manual Supplement Rosemount 5300 and 5400 Series Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction Introduction..................................... page S-1 Safety Messages.................................
More informationApproved Contractor Application (SAFE Form B)
Approved Contractor Application (SAFE Form B) 1. Business Information Company Name: Postal Address: Physical Address: (If differs from Postal) Phone: Mobile: Email Address: Number of Employees: 2. Key
More informationTRANSFORMERS AFTERMARKET SPARES, SERVICE & REPAIR
TRANSFORMERS SPARES, SERVICE & REPAIR 02 TRANSFORMERS ENERGY SOLUTIONS FOR THE GLOBAL POWER INDUSTRY BRUSH Transformers is globally renowned for the quality of its products, innovation and service. Our
More informationExplosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
More informationGas Detector System, Portable/Fixed Oxygen Analysis and Gas Detection Equipment
STANDARD FOR CERTIFICATION No. 2.9 TYPE APPROVAL PROGRAMME NO. 7-473.30/31 / MED A.1/3.30/54 Gas Detector System, Portable/Fixed Oxygen Analysis and Gas Detection Equipment SEPTEMBER 2011 The content of
More informationTop Drive Service Loops. Conventional, Enhanced and Superior Solutions for Drilling Applications
Top Drive Service Loops Conventional, Enhanced and Superior Solutions for Drilling Applications Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective,
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationWhat s up with Arc Flash?
What s up with Arc Flash? Presented by Mark Haskins, CSP Practical Safety Solutions, LLC CONN OSHA Breakfast Roundtable February 18, 2014 2014 Practical Safety Solutions, LLC What is Arc Flash? Definition
More informationUL S RISK ASSESSMENT PROGRAM HELPING UNDERSTAND HAZARDS IN MACHINERY
UL S RISK ASSESSMENT PROGRAM HELPING UNDERSTAND HAZARDS IN MACHINERY Welcome to UL UL is an independent safety science company with more than a century of expertise in standards development, testing and
More informationThermocoax Isopad Heating Solutions for Hazardous Areas
Thermocoax Isopad Heating Solutions for Hazardous Areas We design and manufacture state of the art customized solutions following latest ATEX and IECEx norms and requirements. Our design capabilities range
More informationUsing CFD in Platform Design
Using CFD in Platform Design Eric Peterson, PhD. Principal Consultant Quantitative Risk Analyst Scandpower Inc., Houston,TX Hans Nordstand, Scandpower Inc., Houston, TX Sverre Nodland, Scandpower Inc.,
More informationEXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT
EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT OVERVIEW ASSESSING THE RISK RELATIONSHIP BETWEEN FIRES AND EXPLOSIONS CLASSIFYING HAZARDOUS AREAS INTO ZONES
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationECHM Recommendations for Safety in multiplace medical hyperbaric chambers
ECHM Recommendations for Safety in multiplace medical hyperbaric chambers Coordination and Correspondence : D. MATHIEU, Service d'urgence Respiratoire, de Réanimation Médicale et de Médecine hyperbare
More informationPLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS
January 1997 PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS 1.0 PERMIT 1.1 After receipt of a Building Permit from the City of San Jose Building Department, submit
More informationJourneyman Class Schedule
Journeyman Class Schedule San Diego Electrical Training Center Fall 2015 semester 4675 Viewridge Avenue Vol. 2015-3 tri-annual San Diego, CA 92123-1644 The classes listed in this schedule are designed
More informationWhat Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin?
What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin? Comparing apples-to-apples bids Plant Services Special Report A shock hazard analysis should be included as part of an arc
More informationUnion County Public Schools. Facilities Department. Electrical. Safe Work Practices
1 Union County Public Schools Facilities Department Electrical Safe Work Practices 2 Purpose In accordance with OSHA Standards 1910.331-335, safety-related work practices shall be used by Union County
More informationPART OF THE EUTEX INTERNATIONAL GROUP
Leading provider of international and domestic electrical cables and accessories, and globally accepted hazardous-area electrical and mechanical training, inspections and certifications. PART OF THE EUTEX
More informationFire Code Inspector II
Class specifications are intended to present a descriptive list of the range of duties performed by employees in the class. Specifications are not intended to reflect all duties performed within the job.
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More informationBasic Safety Examination instructions
Name of candidate: This VCA mock examination is only intended for training purposes and is aimed at familiarising candidates with the examination methods. The questions are checked every year for accuracy
More informationMEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV
MEDIUM VOLTAGE SUBSTATION PRACTICES MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV MEDIUM VOLTAGE SUBSTATION PRACTICES This presentation covers some safety aspects
More informationApplication of Real-Time Monitoring to Offshore Oil and Gas Operations National Academy of Sciences Workshop Houston, Texas
Application of Real-Time Monitoring to Offshore Oil and Gas Operations National Academy of Sciences Workshop Houston, Texas April 20, 2015 Dale Bradford Vice President Worldwide Drilling and Completions
More information2CMC300001D0003 November 2007. Enclosed switches ATEX
2CMC300001D0003 November 2007 Enclosed switches ATEX Products for use in explosive atmospheres ATEX ABB offers switches for use within dust explosive atmospheres, Category 3 for use in Zone 22. Here is
More informationFire & Explosion Risks in Service Stations
Fire & Explosion Risks in Service Stations Petrol Vapour Petrol gives off highly flammable vapour even at very low temperatures. Because of the flammability of petrol vapours, service stations carry a
More informationKP4: AGEING & LIFE EXTENSION (ALE) INSPECTION PROGRAMME 1 YEAR ON
KP4: AGEING & LIFE EXTENSION (ALE) INSPECTION PROGRAMME 1 YEAR ON PRESENTATION OUTLINE What is KP4? What have we achieved so far? Supporting activities; external events, web page, network and technical
More informationHEALTH, SAFETY AND ENVIRONMENT HANDBOOK HSE
HEALTH, SAFETY AND ENVIRONMENT HANDBOOK HSE CNOOC Limited 1 Message from CEO Dear Colleagues, CNOOC Limited is the largest producer of offshore oil & gas in China and is one of the largest oil & gas exploration
More informationNo. Name of Legislation Applicable Issues and Requirements Demonstration of Compliance 1. Health and Safety at Work Act 1974
The Police Treatment Centres Health and Safety Legal Compliance Register No. Name of Legislation Applicable Issues and Requirements Demonstration of Compliance 1. Health and Safety at Work Act 1974 2.
More informationInstallation, Operation, and Maintenance Manual
Goulds Pumps Installation, Operation, and Maintenance Manual i-alert Condition Monitor Table of Contents Table of Contents Introduction and Safety...2 Introduction...2 Requesting other information...2
More informationInductive slot sensor
0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
More informationProcess Safety Management of Highly Hazardous & Explosive Chemicals. Safe Work Practices
Process Safety Management of Highly Hazardous & Explosive Chemicals Safe Work Practices Safe Work Practices 1910.119(f)(1) The employer shall develop and implement safe work practices to provide for the
More informationElectrical Safety in the Workplace
Electrical Safety in the Workplace NFPA 70 E Presented by Sabine Mueller What Made Sabine Choose Such a DRY Topic? Ulterior Motive Metso Mueller Engineering has been visiting many scrap yards two or more
More informationdistributing & controlling system solutions
distributing & controlling system solutions your safety our reality Users > Oil and gas industry production storage transport > Petrochemical industry > Chemical industry > Pharmaceutical industry > Food
More informationHazardous Area Classifications and Protections
Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types
More informationInstallation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
More informationSURVIVE INSIDE: Employee Safety in Confined Spaces
SURVIVE INSIDE: Employee Safety in Confined Spaces This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief description of the
More informationWhat is ATEX? The European Regulatory Framework for Manufacture, Installation and Use of Equipment in Explosive Atmospheres
What is ATEX? The European Regulatory Framework for Manufacture, Installation and Use of Equipment in Explosive Atmospheres Ron Sinclair MBE Chair IECEx ExTAG ATEX? ATEX = Atmosphères Explosibles ATEX
More informationFire Alarm System Accessories
Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer
More informationMagnetic Starter - 30A, 120/240V Coils
Manual No: 57701-84 Revision: B Magnetic Starter - 0A, 120/240V Coils Wiring Guide Magnetic Starter Wiring Diagrams for 0 Amp, 120/240 Volt Coils Introduction This Magnetic Starter is a phase, full voltage
More informationFIRE SAFETY GUIDANCE NOTE Risk Assessments for Petrol Filling Stations Required Under Fire Safety Legislation
FIRE SAFETY GUIDANCE NOTE Risk Assessments for Petrol Filling Stations Required Under Fire Safety Legislation Number: GN75 This Guidance Note provides information on the legislation relating to risk assessments
More informationCEILING CASSETTE FAN COIL UNIT
CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and
More informationFlameproof Audible Signal 115 db (A) Series YA90
Clifford Snell www.stahl.de > Max sound output 115 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > 32 selectable tones meeting international regulations > Light
More informationNational Craft Assessment and Certification Program S P E C I F I C A T I O N S
National Craft Assessment and Certification Program S P E C I F I C A T I O N S INDUSTRIAL ELECTRICIAN V4 ELEC26_O4 Released September 2013 Focus Statement An Industrial Electrician must be able to interpret
More informationDavid O Brien, CMP Products (David.OBrien@cmp-products.com)
David O Brien, CMP Products (David.OBrien@cmp-products.com) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More informationPre-Apprenticeship Training Apprentice Training Post-Trade Training Short Refresher Courses
The College of Electrical Training (CET) is the major private training provider for the Western Australian electrical & telecommunications industries. Course Delivery Profile Pre-Apprenticeship Training
More informationBrochure. ABB Customer Training Program for Motors and Generators Sharing knowledge and creating value
Brochure ABB Customer Training Program for Motors and Generators Sharing knowledge and creating value With expertise, and a comprehensive portfolio of products and life-cycle services, we help value-minded
More informationTraining Division Overview
DALLAS FIRE-RESCUE DEPARTMENT Training Division Overview Public Safety Committee May 9, 2016 MISSION STATEMENT To provide training for new and incumbent members to ensure that Dallas Fire-Rescue (DFR)
More informationUnderstanding Arc Flash
Understanding Arc Flash Presented by Eddie F. Jones, PE 1 2 3 4 5 Five to 10 arc flash explosions occur in electric equipment every day in the United States. This number does not include cases in which
More informationSite and Storage Conditions for Class 3.1 Flammable Liquids
Site and Storage Conditions for Class 3.1 Flammable Liquids Introduction Contents Introduction... 1 SITE AND STORAGE CONDITIONS...2 Part 1 General Flammability Conditions...2 Part 2 Conditions Relating
More informationAn Introduction to ATEX -
An Introduction to ATEX - Meeting the Challenges of European Directive 94/9/EC (ATEX 95) Presented by Andy Holmes ATEX Consultant, TÜV Product Service Ltd 1. Introduction 1.1 Objectives of explosion protection
More informationJOURNEYMAN CLASS DESCRIPTIONS
ADVANCED LIGHTING CONTROL This class is truly the next frontier in Green Energy Solutions and is a must for all electricians who want to participate in this future boom. This class will train you to correctly
More informationUNIVERSITY INDUSTRY COLLABORATION: SAFETY ENGINEERING EDUCATION AT KU LEUVEN
UNIVERSITY INDUSTRY COLLABORATION: SAFETY ENGINEERING EDUCATION AT KU LEUVEN Jan Degrève 1, Jan Berghmans* 1, Geert Boogaerts 2 1 Katholieke Universiteit Leuven, Department of Chemical Engineering, Belgium
More informationNote: Firefighters wishing to take this course must have valid air brake endorsement on their driver s license.
Seminar and Program Descriptions Two-Day Fire and Emergency Services Instructor (FESI) for Defensive Firefighting (Basic) This is a must for firefighters who take on the training role in their fire department.
More informationFire Risk Assessment Safety Checklist
Fire Risk Assessment Safety Checklist This checklist has been prepared to help you comply with The Regulatory Reform Fire Safety Order 2005 What is the Regulatory Reform (Fire Safety) Order 2005? The Regulatory
More informationCompressed Gas Cylinder Safety
Compressed Gas Cylinder Safety I. Background. Due to the nature of gas cylinders, special storage and handling precautions are necessary. The hazards associated with compressed gases include oxygen displacement,
More informationACCEPTANCE TESTING, COMMISSIONING & START UP PREDICTIVE & PREVENTATIVE ELECTRICAL TESTING SERVICES ENGINEERING SERVICES
INFRARED INSPECTIONS ACCEPTANCE TESTING, COMMISSIONING & START UP PREDICTIVE & PREVENTATIVE ELECTRICAL TESTING SERVICES ENGINEERING SERVICES 24/7 EMERGENCY SERVICE AND REPAIR DELIVERING A HOST OF TECHNICAL
More informationCOMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.
Page 1 of 5 COMPRESSED GASES A compressed gas is defined as any mixture of gases in a container with a pressure exceeding 40 psi. at 70 o F, or 104 psi. at 130 o F; or any flammable liquid with an absolute
More informationWorkshop Self Inspection Checklist WORK01
Workshop Self Inspection Checklist WORK01 General Mechanical Workshops Location Assessor Date This core checklist is provided by the Health and Safety Department as a template, which provides a basic framework
More informationTechnical Note Series
Technical Note Series SKIN CONDUCTANCE SENSOR (SA9309M) S TN0 0 0 8-0 0 S k i n C o n d u c t a n c e S e n s o r Page 2 IMPORTANT OPERATION INFORMATION WARNING Type BF Equipment Internally powered equipment
More informationTechnical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
More informationCONFINED SPACE PROCEDURE
Document uncontrolled when printed Procedure ID no 0460/05 CONFINED SPACE PROCEDURE This procedure is applicable to: All Department of Education and Children's Services employees. DOCUMENT CONTROL Managed
More informationWorker Health and Safety on Offshore Wind Farms. June 17, 2014
Worker Health and Safety on Offshore Wind Farms June 17, 2014 Committee VADM James C. Card, United States Coast Guard (retired), Chair Dr. Thomas J. Lentz, National Institute for Occupational Safety and
More informationFundamental of Maintaining Equipment Integrity
Fundamental of Maintaining Equipment Integrity Presentation for Well Control Asia Pacific 2009 Conference & Exhibition, 18-19 November STSA Pte Ltd Formerly known as Stork Technology Services Asia Pte
More informationINTRODUCTION ARC FLASH PROTECTION AND SAFETY MEASURES. September 2010
ARC FLASH PROTECTION AND SAFETY MEASURES September 2010 Introduction Hazards of Electrical Energy Electrical Safety Program Safety-Related Work Practices Electrical Safety Procedures Presented By: Ken
More information1200 New Jersey Avenue, SE of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety. ocr 2 6 2012
U.S. Department 1200 New Jersey Avenue, SE of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety ocr 2 6 2012 Adm inistration Mr. Larry Hjalmarson Vice President Safety, Environment
More informationEquipment vs. Component
Equipment vs. Component Dipl. Ing. Ursula Aich Regierungspräsidium Darmstadt National focal point for the Market Surveillance in the field of the ATEX-Directive in Germany Chair of ATEX ADCO Free movement
More information