Nelson Washbasin Pre-Install Instructions
|
|
- Jody Baker
- 7 years ago
- Views:
Transcription
1 Nelson Washbasin Pre-Install Instructions Pre-Install Instructions Please see the below for instructions to prepare site for installation. This product is designed for indoor use in a wet environment, such as a bathroom or washroom. It may only be used in an environment corresponding to the system s IPX6 rating. Ensure that the installation location environment also complies with the following operating parameters: Tempreture - 5 C to 40 C, Relative humidity - 20% to 30 C (condensation free), Atmospheric pressure to 1060 hpa. Ensure a 230 volt (5 amps) fuse spur is installed by means of an approved moisture-resistant wall box (Fig 1.) or by leading an approved cable through the wall for connection outside the room (Fig 2.). The product is supplied with a plug attached, but this will need to be replaced with an IP-rated plug and socket combination appropriate to the location of the socket relative to moisture, or alternatively the product may be hardwired to a mains supply. All electrical connections are to be carried out by a qualified electrician. AC Power to be switched on in advance of OpeMed engineers arrival. All flooring must be level and complete. All walls must be decorated and complete (as per fixing instructions on page 3). Nelson Washbasin 1
2 Fig. 1 (Recommended) Fig. 2a Fig. 2b 666 (26 2 /8) Fig. 2c 170 (6 6 /8) Hot/Waste/Cold Feed Pipes (3) (3) 120 ) (46 /8 340 (13 /8 3 ) Fuse Spur Fig. 2a Fig. 2c Fig. 2b 2
3 Fixing Instructions See below for weight limits, fixing recommendations and requirements. The load on each anchor (screw) has been calculated, both for the product sustaining normal load and the product sustaining maximum load. You will find a list of different anchor types and the load they can sustain when fitted into different wall types and suggestions as to how to reinforce a plasterboard wall with plywood. Please note: These suggestions are to be considered as guidelines only. When loaded with Maximum load each anchor supports... When loaded with Maximum load incl. safety factor each anchor supports... Nelson Washbasin 150kg 20kg 225kg 30kg Maximum Load 2 - Wall Anchors Choosing the appropriate anchor for a specific type of wall Wall Type Fischer Type Anchor Type Maximum load Concrete >B25 SX12 Coach Screw 10x kg Concrete >B25 SX12 Bolt 10x kg Concrete >B kg Solid Brick >= Mz12 SX12 Coach Screw 10x80 75 kg Solid Brick >= Mz12 SX12 Bolt 10x70 75 kg Solid Brick >= Mz12 Solid Sand Lime Brick >= Hlz12 SX12 Coach Screw 10x kg Solid Sand Lime Brick >= Hlz12 SX12 Bolt 10x kg Solid Sand Lime Brick >= Hlz12 Hollow Brick >= Hlz12 SX12 Coach Screw 10x80 30 kg Hollow Brick >= Hlz12 SX12 Bolt 10x70 30 kg Hollow Brick >= Hlz12 Aerated Concrete P4 SX12 Coach Screw 10x80 50 kg Aerated Concrete P4 SX12 Bolt 10x70 50 kg Aerated Concrete P4 GB14 M10x kg Aerated Concrete P4 60 kg 3
4 Wall Anchors Continued... Hollow Sand Lime Brick >=KSL12 Hollow Sand Lime Brick >=KSL12 SX12 Coach Screw 10x80 40 kg SX12 Bolt 10x70 40 kg Plasterboard (2 x 12,5 mm) KD8 Toggle 39 kg Plasterboard (2 x 12,5 mm) water-resistant KD8 Toggle 58 kg Plasterboard (1 x 12,5 mm) re-enforced with 22 mm plywood KD8 Toggle 133 kg Plywood 22 mm KD8 Toggle 133 kg Chipboard 19 mm KD8 Toggle 86 kg Maximum Load 3 - Check List Recommended load if wall is built in compliance with national standards The OpeMed Nelson Washbasin is compatible with: Brick walls (solid brick or hollow brick) >Mz12 or >Hlz12 2 x1.5 studs, 22 mm plywood or equivalent 2x 12.5 mm plasterboard or equivalent Aerated concrete walls > G2 Concrete walls > B15 4
5 Maximum Load Reinforcements Reinforcements of walls should always comply with national standards Plasterboard 12,5 mm (x2) (water-resistant) Plywood 22 mm (x 2) Please refer to mounting instructions for indication of the placement in height of plywood plate. Plasterboard 12,5 mm (x2) Product Plywood 22 mm (x 2 so that tip of anchor is not exposed) Hollow between walls Screw to fit wall type (see page 2) Plasterboard (other side) Washer 5
Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V
Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................
More informationSaferand easierinstallation
EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little
More informationUNIVERSAL MOUNTING SET (UMS) FOR ARTOLINK FSO EQUIPMENT
UNIVERSAL MOUNTING SET (UMS) FOR ARTOLINK FSO EQUIPMENT 1. DESIGNATION AND COMPOSITION OF THE SET. The present manual is meant for familiarizing with construction, mounting and operational regulations
More informationINSTALLATION & USER INSTRUCTIONS WALL MOUNTED LCD ELECTRIC FIRE
INSTALLATION & USER INSTRUCTIONS WALL MOUNTED LCD ELECTRIC FIRE MODELS COVERED BY THESE INSTRUCTIONS GB IE EVOKE LCD ELECTRIC- F500176 Focal Point Fires plc. Christchurch, Dorset BH23 2BT Tel: 01202 499330
More informationEVOKE LCD ELECTRIC WALL HEATER MODEL : L23LCD INSTALLATION AND USER INSTRUCTIONS
EVOKE LCD ELECTRIC WALL HEATER MODEL : L23LCD INSTALLATION AND USER INSTRUCTIONS All instructions must be handed to user for safekeeping Revision A - 07/08 Country(s) of destination - GB/IE Focal Point
More information1. Geo Vertical 2. Geo Horizontal
1 2 1. Geo Vertical 2. Geo Horizontal 1 2 3 1. Geo Vertical 2. Geo Vertical with towel rail 3. Geo Vertical with cover plate Geo Vertical 47 Geo Vertical Dimensions Connections Range GEVW_Geo Vertical
More informationOperating Instructions. Room temperature controller
Operating Instructions 1. Area of application The room temperature controller is used to regulate the temperature in closed rooms such as flats, schools, function suites, workshops, etc. Safety instructions
More informationAMS 120. EFT Guest Card Terminal & Refund unit
AMS 120 EFT Guest Card Terminal & Refund unit ACCOUNT MANAGEMENT STATIONS Wall mounted kiosk offering Visitor card purchase and refund Card deposit EFT purchase, refund and loading Full statement facilities
More informationHow To Use A Mnet Converter
Photo M-NET Converter Descriptions PAC-SF8MA-E Model change from PAC-SF80MA-E A-control Mr. SLIM models can be connected to "M-NET" through optional M-NET converter so that they can be monitored / controlled
More informationInstallation. Smart-UPS VT and MGE Galaxy 3500. Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V
Installation Smart-UPS VT and MGE Galaxy 3500 Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V Contents Safety... 1 SAVE THESE INSTRUCTIONS...............................
More informationThis unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
More informationGENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)
GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES 1. PROTECTIVE SCREENS (a) Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic) Typically, 15 kg m -2 (1.3 mm) sheet lead or its shielding
More informationTYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE
TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE A. GENERAL NOTES: Service entrance line and load conductors, conduit straps, weatherhead, lock nuts, bushings, connectors, and
More informationWall installation for Samsung Galaxy
1 Scope of delivery... 02 2 Mounting... 03 2.1 Mounting preparation table of contents 2.2 Mounting on cavity walls / lightweight walls... 04 2.2.1 Wall notch 2.2.2 Angles 2.2.3 Insert the lower case 2.2.4
More informationSTR-600 Plate Dryer. 1. What it s meant for?
STR-600 Plate Dryer 1. What it s meant for? Device is meant for water damage drying on local wetted areas. The device suits best for different stone type structures, such as concrete, brick structures
More information1. Description. 2. List of Accessories included A B C F G H
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to
More informationAwning Instructions. Full Cassette 1.5m to 6m
Awning Instructions Full Cassette 1.5m to 6m English Full Cassette Manual & Electric Instructions Contents Warning 1.5m - 3.5m Awnings 8 x Expansion bolts ** 2 x brackets 1 x Awning 1 x Winder 4.0m -
More informationfischer Test Report Fixing Tests for Wienerberger Porotherm blocks
fischer Test Report Fixing Tests for Wienerberger Porotherm blocks CONTENTS. Test Parameters... Substrates Tested Wienerberger Porotherm 90 &. Fixings Products Tested... Fischer Nylon UX Plug... Fischer
More informationSamuel Shorty Bunk Bed
Samuel Shorty unk ed - Please keep for future reference / 88/999 0/8 IMPORTANT NOTE: The top surface of the mattress should not come above this line. imensions Width - 8cm epth - 8cm eight - 0cm IMPORTANT
More informationPS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: info@juicegoose.com www.juicegoose.com 06-06 CONGRATULATIONS
More informationAT&T. PARTNER Plus Door Phone. Installation and Operation Manual
AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a
More informationSIMULATION PRE-INSTALLATION GUIDELINES CONTRACTOR REQUIREMENTS FOR ROOM PREPARATION
SIMULATION PRE-INSTALLATION GUIDELINES CONTRACTOR REQUIREMENTS FOR ROOM PREPARATION version 1.0_042011 www.foresightsports.com TABLE OF CONTENTS INTRODUCTION 1 COMPONENTS-AT-A-GLANCE 2 SPACE DIMENSIONS
More informationLIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
More informationElo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors
Installation Manual Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors SW602206 Rev B Table of Contents Chapter 1: Safety Warning... 3 Chapter 2: Kit Contents... 4 Included in Kit...
More informationInstallation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale
Installation information METTLER TOLEDO MultiRange DW150 / DW150T wall scale DW150 / DW150T wall scale Contents Contents Page 1. Installation... 2 1.1 Preparatory work... 2 1.2 Installing the wall plates
More informationElectrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
More informationBatibox TM flush-mounting boxes for dry partitions
flush-mounting boxes for dry partitions 800 51 800 42 800 53 800 54 800 42 + 800 71 800 77 Cat.Nos 1-gang boxes For 1 module 20 800 40 Drilling diameter 32 mm Depth 40 mm For 1 gang or 2 modules For wiring
More informationChapter 5 FLOOR LOADING AND WEIGHTS
Chapter 5 FLOOR LOADING AND WEIGHTS Section 1.0 Floor Loading Section 2.0 Seismic Data The CT system has a total floor load of approximately 6660 lbs (3021 kg). About 5050 lbs (2291 kg), including patient
More informationZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.
ZAPPY 3 OWNER S MANUAL Read this manual completely before riding your Electric ZAPPY 3. TECHNICAL INFORMATION Model No. : ZAPPY 3 Product size Type of motor Motor power Battery type Battery Charger Charging
More informationCoolWave r 2 Phase Control Board and Cable Replacement Kits
Instruction Sheet P/N 1102452A CoolWave r 2 Phase Control Board and Cable Replacement Kits Two kits are available to replace the CoolWave 2 phase control board: S S Phase Control Board and Cable Kit (required
More informationMODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand
9041381- Issue 6 4/11 MODEL: DV72 Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation: Configuration
More informationInstallation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
More informationRequirements for Electrical Installations
ARTICLE 110 Requirements for Electrical Installations INTRODUCTION TO ARTICLE 110 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS Article 110 sets the stage for how you ll implement the rest of the NEC. This
More informationBathroom Cabinet. Installation & User Guide. Illuminated Mirrors. www.illuminated-mirrors.uk.com
Illuminated Mirrors The UK s Largest LED Mirror Supplier to Trade and Retail Installation & User Guide Bathroom Cabinet www.illuminated-mirrors.uk.com Bathroom Cabinet Installation & User Guide Thank you
More informationHollow or Cinder Block Wall Mount Job Aid
Summary This Job Aid covers: Hollow or Cinder Block Wall Mount Job Aid Hollow or Cinder Block wall Mount Bracket Installing the Mount Bracket into Cinder Block This Job Aid supports the Technician audience.
More information08-07-2015 MOUNTING INSTRUCTIONS
08-07-2015 i3hawm E(BASIC) MOUNTING INSTRUCTIONS 1. INDEX 1. Index 3 2. Important safety instructions 4 3. Maximum loads 7 4. Different configuraties 8 5. Part list i3hawm-e (basic) 9 6. Preparing frame
More informationParts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!
Parts Manual TWIN 2 & 3 Parts & Accessories F210846R01 Your efficiency is our Challenge! All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm
More informationPark View Place. Compass. House. Royal Wharf Gardens Endeavour. House. Thameside. Sienna. House. House. Apartments Townhouses.
The Townhouses Park View Place A A Compass House A T T T Royal Wharf Gardens Endeavour House T A A Thameside House T Sienna House A A A A T Apartments Townhouses River Thames Compass House Compass House
More informationIMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
More informationRousseau 10. User Guide
Rousseau 10 User Guide Base station overview ➀ LED signals White, permanent light: - Base station ready, you can register a handset Slow flashing white light: - Paging call in progress - Active call (you
More informationORION 40 DS lamp WALL version
Rev.1 Page 1 of 5 ORION 40 DS TECHNICAL DATA 180 1806 Performances at 80cm distance ORION 40 DS Light intensity at 80cm (Ec) 130klx (5000K) 60klx (with DENTAL CARE) Color temperature (K) 4500/5000 Color
More informationDrayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
More informationFLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
More informationInstallation options, Europe
Room Display Installation options, EUROPE. Installation options, Europe Option Installation type Cabling Power page 1 Wall, directly Concealed cable 220 V 4 2 Wall, directly Concealed cable PoE Powered
More informationKnauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap
Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet
More informationSERVICE MANUAL Order No.WH0911S001V0
SERVICE MANUAL Order No.WH0911S001V0 Electrical Water Heater Model No. FCD-JTSA50-III FCD-JTSA60-III FCD-JTSA70-III FCD-JTSA80-III! WARNING This service information is designed for experienced repair technicians
More informationDM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button
DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button collective/synoline600 AlgoRex Synova Manual call point to all fire detection system control
More informationTECH SUPPORT 407-235-0243 1276 NORTH SEMORAN BLVD ORLANDO FL32807
The Talon Standard Installation Wiring Diagram Optional Pre-Install Harness 12VDC Power ForProgramming Only Should Not Be Used Ignition Input Not Used Ground Pre-install Harness (splice into red wire in
More informationSplit units TH with hermetic compressors
Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split
More informationMounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer
5000020G Warning Before Installation English Power off the Network Camera as soon as smoke or unusual odors are detected. Do not place the Network Camera on unsteady surfaces. Do not insert sharp or tiny
More information609 West Rock Road, Radford,VA 24141 540-633-5000 / (fax) 540-731-3712 RECOMMENDED ATTACHMENTS & CONNECTION DETAILS
609 West Rock Road, Radford,VA 24141 540-633-5000 / (fax) 540-731-3712 RECOMMENDED ATTACHMENTS & CONNECTION DETAILS INDEX OF DRAWINGS SECTION A: A-1 = METAL TRACK TO PANEL ATTACHMENT A-2 = WOOD PLATE TO
More informationLAYING BLOCK AND BRICK
LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct
More informationAchat 115MA full-range speaker. user manual
Achat 115MA full-range speaker user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de
More informationRapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580
Any Queries Call : 08000 23 23 23 Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590 Rapide Inline Ceiling Extractor Fan, White Fascia Illuminated 41800040670 Rapide Inline Ceiling Extractor
More informationAchat 208 HL / 208 HR passive mid-range speaker. user manual
Achat 208 HL / 208 HR passive mid-range speaker user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet:
More informationVision Engravers and Routers PRE-Installation Guide. 2015 Vision Engraving & Routing Systems
Vision Engravers and Routers PRE-Installation Guide Revised: 8/19/2015 Vision Engravers and Routers PRE-Installation Guide All rights reserved. No parts of this work may be reproduced in any form or by
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More informationTablet Management Rack 16
Tablet Management Rack 16 User's Guide Table of Contents Hazard Symbols Review... 2 Components... 2 Charging Set-up... 3-4 LED and Syncing... 4-5 Cleaning and Maintenance... 6 Specifications... 6 Service
More informationMarch 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
More informationCAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
BeoLab 4000 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified
More informationSafeguard Waterproofing Systems. Creating useable. living space. by making basements dry
Safeguard Waterproofing Systems living space Creating useable by making basements dry The SWS waterproof cement system The Safeguard SWS Structural Waterproofing System is designed to be both highly effective
More informationINSTRUCTIONS: LocknCharge Laptop Carts
INSTRUCTIONS: LocknCharge Laptop Carts www.lockncharge.com Extra Tools required: Hammer, Philips head screwdriver, medium adjustable spanner. (Allen key supplied) (Panel colours for illustration purposes
More informationBathroom Installation Guide
Bathroom Installation Guide Step-by-step installation of your cabinets We do a lot of groundwork to make it as simple as possible for you to assemble and install your new bathroom furniture yourself. We
More informationAfter reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE
86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is
More informationProgrammable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
More informationOld people and nursing homes. Old people and nursing homes, rehab/medical. SPECIAL SOLUTIONS. Security and comfort for every stage of life.
. SPECIAL SOLUTIONS. Security and comfort for every stage of life. 401 Paracelsus wash basin to DIN 1386, DIN-EN 32 without overflow, pre-punched tap-hole Model no.: 251060 Dimensions: 640 x 490 mm Weight:
More informationStep by Step instructions How to screw in wood and plastic
Step by Step instructions How to screw in wood and plastic Different screw heads As well as the simple slotted screw head, there are three different types of screw heads into which the screwdriver or bit
More information172 Holesaws Overview Bosch Accessories for Power Tools 09/10. 189 Diamond holesaw. with Power-Change adapter. 190 Diamond drill bits
Holesaw 172 Holesaws Overview Bosch Accessories for Power Tools 09/10 Overview 178 Progressor holesaw 189 Diamond holesaw 196 Hole cutters 183 Sheet Metal holesaw 190 Diamond drill bits 186 Multi Construction
More informationSteel Door Frame Installation in Steel Stud Construction
Steel Door Frame Installation in Steel Stud Construction For use with the Steel Door Institute (SDI) video How to Install a Steel Door Frames in Steel Stud Construction This manual gives you step-by-step
More informationNumber Wheeler P/N Description Set Rex P/N Notes 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8)
1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8) 4 5 600130 Spring Washer (8mm) 4 6 600344 Roll Pin (M6x30) 4 7 600129 Socket Hd Cap Screw (M8x25) 4 8
More informationUSER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
More informationNumber Wheeler P/N Description Set Rex P/N Notes
1 607051 Base 1 A050 2 607052 Motor Cover 1 A052 3 600778 Socket Hd Cap Screw (M8x60) 2 4 607053 Scrap Receiver 1 A053 5 607054 Tank Upper Cover 1 A054 6 607055 Oil Pot 1 A055 7 607056 Strainer 1 A056
More informationInstallation GUIDE IMPORTANT: KEEP THIS MANUAL AND THE PRODUCT ID LABEL IN A SAFE PLACE
Installation GUIDE IMPORTANT: KEEP THIS MANUAL AND THE PRODUCT ID LABEL IN A SAFE PLACE 1. Product description The device is an external module capable of connecting Panasonic air-conditioning units into
More informationPlease also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
More information16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationSAN25 (6904-002001 <00>)
SAN25 () Wood 002752.eps Concrete 13mm (1/2 in.) 5mm (3/16 in.) Sanus Systems 2221 Hwy 36 West Saint Paul, MN 55113 USA Customer Service Americas: 800-359-5520 651-484-7988 info@sanus.com Europe, Middle
More informationClose Coupled & Back To Wall WC Saintaryware. Fitting Instructions
Close Coupled & Back To Wall WC Saintaryware Fitting Instructions Before starting any installation project please consider the following: Prior to drilling into walls, check there are no hidden electrical
More informationBuilding Regulations P.4. Socket Outlets P.6. Other Considerations P.10. Training Seminars P.24
1 Introduction For well over one hundred years the Wiring Regulations have provided the rules which must be followed to make sure that electrical installations are safe. The introduction of the 17 th Edition
More information50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance
02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW
More informationAL-System 6 AQUALOOP System 6. Installation and operating instructions WATER IS OUR ELEMENT. www.intewa.com
AL-System 6 AQUALOOP System 6 Installation and operating instructions WATER IS OUR ELEMENT www.intewa.com Table of contents 1. Introduction and general instructions... 2 2. Scope of delivery... 3 3. Technical
More informationElectrical Practices for Construction Work
1. Purpose Electrical Practices for Construction Work The purpose of this Code is to provide practical guidance and set minimum safety requirements for electrical practices on all construction sites in
More informationUB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
More informationElectricity to your property
Vattenfall Distribution AB Electricity to your property How an electrical connection is made and what you need to consider How electricity reaches your property 8 simple steps! 1. Please leave plenty of
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationModel 53603. Owner s Manual. Español - P. 19 Français - P. 39
Model 53603 Owner s Manual Español - P. 19 Français - P. 39 Table of Contents I. Introduction............................ 1 Sample Watering Plan.......................... 1 II. Installation...........................
More informationRepair and Renew Grant. Croydon RRG Scheme
Repair and Renew Grant Croydon RRG Scheme Development & Environment April 2014 Croydon Repair and Renew Grant Scheme Support for independent businessess and property owners affected by flooding December
More informationQFP910. Water detector. Building Technologies. CE1N2732en. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
More informationOwners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,
More informationResidential Inspection Guidelines
Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against
More informationDetection System Model 3800 Series
Detection System Model 3800 Series Architect/Contractor Information Package 3M Library Systems 3M Center, Building 225-4N-14 St. Paul, Minnesota 55144-1000 Copyright 2001-2006 3M. All rights reserved.
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationAwning Instructions. Standard Manual 1.5m to 4.5m
Awning Instructions Standard Manual 1.5m to 4.5m English Standard Manual Instructions Contents Warning 1.5m 3.0m Awnings 4 x Expansion bolts (2 per bracket)** 2 x brackets 1 x Awning 1 x Winder handle
More informationBUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE
BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE Toll Free Telephone Numbers Residential Services 800.454.3853 Commercial Services 800.653.5307 Utility Locating Company N.C. 800.632.4949 S.C. 888.721.7877
More information2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS
2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS The LOGIX wall assembly has no need for an additional vapor barrier, the solid concrete core covered with the low permeance EPS (Type II) foam
More informationPackaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
More informationAdditions and Alterations
Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal
More informationFig B36 Stainless Steel 'T' Type or Basket Type Strainers
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationOperation manual and Spare parts list 1400 - EL PUMP. November
Operation manual and Spare parts list 1400 - EL PUMP 10 GB November 1 KIMADAN A/S KIMADAN A/S 2 Operational manual and spare parts list 1400 El-pump 15, 20, 25 HP 5 30 kw 6 1. Description.. 3 2. Installation
More informationAxor ShowerCollection with Philippe Starck Information & inspiration for professionals
Axor ShowerCollection with Philippe Starck Information & inspiration for professionals ConTenTS 04 The principle 10 The planning examples 35 The installations 43 The product overview 50 The references
More information