2.3. Design Guideline. Water Supply Booster Pump Station

Size: px
Start display at page:

Download "2.3. Design Guideline. Water Supply Booster Pump Station"

Transcription

1 2.3 Design Guideline Water Supply Booster Pump Station

2 2.3 Water Supply Booster Pump Station Design Guideline Table of Contents Design Guideline... 1 Water Supply Booster Pump Station... 1 Description:... 3 Objective:... 3 Reference Documents:... 3 Component Description: Pump Station Site Electricity Supply Switchboard Perimeter Fence Pumps Pump Controls Pipework Electromagnetic Flow Meter Standard Drawings and Site Photos... 7 Schematic Plan:... 8 Figure 1 Avenel Park Estate Site Layout Plan... 9 Figure 3 and 4 Pump Configurations Avenel Park Estate

3 2.3 Water Supply Booster Pump Station Design Guideline Description: The water supply booster pump station is a component of the reticulation system and will pump to an elevated water supply storage tank upon demand. The operation of the pump will be governed by a low water level signal from the tank. Objective: The objective of the water supply booster pump station is to provide a water supply that meets the customer demands for reliability of supply and flow. Reference Documents: WSAA MRWA Water Supply Code of Australia GVW Supplement to the WSAA MRWA Water Supply Code of Australia GVW Product Manual GVW Development and Construction Manual Design Manual Water Storage Tank (To be prepared) GVW General Electrical Specification GVW Booster Pump Station Specific Electrical/Requirements GVW Building Aesthetics Design Manual 3

4 2.3 Water Supply Booster Pump Station Design Guideline Component Description: 1. Pump Station Site The pump station site is to be located within a reserve in favour of the Goulburn Valley Region Water Corporation. The pump site is to be selected where a sufficient water supply is provided at peak periods for the pump to operate (water pressure and flow). Advice is to be sought from Goulburn Valley Water s Planning and Project Development Section. The site is not to be encumbered by existing or proposed overhead power lines and is to provide satisfactory coverage for monitoring and control via SCADA. The site must be accessible by vehicles by means of an all weather road. The minimum width of the access is 3 metre wide and sufficient space is to be provided for a light truck vehicle to turn and for at least 1 parking space. The surrounding area of the pump station site is to be covered with a minimum of 100mm compacted crushed rock or similar approved material to provide an all weather access to the site. The layout of the pump station must ensure that the available space for maintenance purposes is maximised. A minimum of 1 metre clearance between all assets and the reserve title boundary must be achieved. 2. Electricity Supply The capacity of the electricity supply system needs to be investigated to ensure that there is an electricity supply capable of meeting pump station loading within electricity supply regulations for both Amperage and Voltage. If a development project, then the connection to the grid is to be arranged by the consultant including the meeting of associated costs as part of the project. These include: Costs to hook into grid Expected running costs of pump annually and life time Pump wiring requirements, Generator change over ability All weather control box 4

5 2.3 Water Supply Booster Pump Station Design Guideline 3. Switchboard The electrical cabinet and switchboard is to be in accordance with the GVW Standard Specification for Switchboards. This is available upon request via to GVW General Electrical Specification GVW Booster Pump Station Specific Electrical/Requirements 4. Perimeter Fence The site perimeter is to be fenced with a 1.80m high black plastic coated chain mesh security fencing around the complete site boundary. A minimum 3m wide black plastic coated chain mesh security hinged double gate with padlock keyed is to be provided at the entrance to the site. Minimize aesthetic issues for neighbouring properties and the general public. This may require perimeter buffering planting or screens and should be investigated with Council and local residents. Please refer to the GVW Building Aesthetics Design Manual. 5. Pumps All booster pump stations that boost water supply to an elevated water supply storage tank are to equipped with 2 No. complete and identical pumpsets, (duty and standby) and are to be rated to operate in an open weather environment. The selection of the pump and the design of the inlet water main to the storage tank should minimise the pressure spike to customers to 5 metres head, if there is a single inlet/outlet pipeline to the tank. The preference is dedicated inlet and outlet water mains. The noise generated from the start, stop and running of the pumps is to be considered and must comply with EPA requirements. If noise is an issue to neighbouring properties, then sound attenuation measures, such as an enclosure should be considered. 5

6 2.3 Water Supply Booster Pump Station Design Guideline Pumps should be located adjacent to the access/parking area, so that there is unrestricted access to pumps to allow lifting as required using a small GVW crane truck. Pumps and pipework are to be secured to a suitable concrete slab, which drains surface water adequately. 6. Pump Controls The pumps are to operate on a duty call and duty stop set point from the storage tank. There is to be a telemetry (radio) link between pumps station and storage tank. Cable is not to be used when the distance between the pumps and the tanks is greater than 100m. The pumps should have an automatic changeover between the duty and standby. The preferred arrangement is for the water level in the storage tank to be relayed to the pump station, which displays all information and is connected to SCADA. 7. Pipework All pipework in the vicinity of the pumps is to be above ground and comprise flanged or welded stainless steel or flanged DICL pipework. Inlet and outlet pipes to be cast into the 100mm thick reinforced concrete slab. All below ground pipe work within the pump station site must be DICL material. 6

7 2.3 Water Supply Booster Pump Station Design Guideline 8. Electromagnetic Flow Meter A magnetic flow meter is to be installed on the discharge pipework from the pumps and located above ground. Installation must comply with the electromagnetic flow meter design guideline. The discharge flow rate is to be displayed on the electrical cabinet and also linked to SCADA, so that it can be viewed remotely. 9. Standard Drawings and Site Photos Site layout plan for Avenel Park Water Supply Booster Pump Station (JWS/2062) A post construction review of the pump station indicates the following changes should be made for future similar pump stations: Control cabinet is located between the pumps and the access. This requires any pumps to be lifted over the control cabinet for maintenance and repairs. The control cabinet could have been located at the other end of the pump slab. Aesthetics Neighbouring land owners have complained that the pump station is unsightly, and shrubs are to be planted along the frontage to the pump station. This could have been addressed during the design stage, by requesting that the developer get approval for the pump station from Council and the adjacent land owners. Please refer to GVW Building Aesthetics Design Manual Version No. Date Description Prepared by: Approved by: 1.0 Feb 2010 Original draft issue Claire Speedy Steven Nash 2.0 Mar 2010 Revised draft issue Steven Nash Bruce Anderson 3.0 Sept 2010 Revised Format Jeff Block 3.1 June 2011 Revised format Adam Glasson Michael Welk 3.2 Sept 2012 New numbering and front page design Adam Glasson Michael Welk 7

8 Water Supply Booster Pump Station Design Manual Schematic Plan: 8

9 Water Supply Booster Pump Station Design Manual Figure 1 Avenel Park Estate Site Layout Plan 9

10 Water Supply Booster Pump Station Design Manual Figure 2 - As constructed layout of the Avenel Park Estate pump and pipework 10

11 Water Supply Booster Pump Station Design Manual Figure 3 and 4 Pump Configurations Avenel Park Estate 11

12 Water Supply Booster Pump Station Design Manual Figure 5-12

Design & Access Statement : Proposed Internal Devlopment & External Plant to Data Centre Facility, 35 Imperial Way, Croydon.

Design & Access Statement : Proposed Internal Devlopment & External Plant to Data Centre Facility, 35 Imperial Way, Croydon. Design & Access Statement : Proposed Internal Devlopment & External Plant to Data Centre Facility, ARC-RP-A-002 Prepared by ARCMC Ltd July 2012: Issue A Contents 1. Introduction 2. Application Proposal

More information

Electrical. This section applies to the design and installation of building power distribution systems.

Electrical. This section applies to the design and installation of building power distribution systems. Basis of Design This section applies to the design and installation of building power distribution systems. Design Criteria This section contains the architectural, structural and mechanical provisions

More information

Standards for Water, Sewer, and Sewage Lift Station Design

Standards for Water, Sewer, and Sewage Lift Station Design Standards for Water, Sewer, and Sewage Lift Station Design February 2015 Edition I. Plan Format Requirements General Requirements Water Line Requirements Sewer Line Requirements II. III. IV. Water Design

More information

SHOALHAVEN RIVER CROSSING (NOWRA NSW) SEWER MAIN REPAIR. Steve Glennan. Shoalhaven Water, Shoalhaven City Council

SHOALHAVEN RIVER CROSSING (NOWRA NSW) SEWER MAIN REPAIR. Steve Glennan. Shoalhaven Water, Shoalhaven City Council SHOALHAVEN RIVER CROSSING (NOWRA NSW) SEWER MAIN REPAIR Paper Presented by: Steve Glennan Authors: Steve Glennan, Co-ordinator, Phil Critchley, Acting Operations Manager, Shoalhaven Water, Shoalhaven City

More information

Does your new building

Does your new building Does your new building need electricity? To save you time and money, talk to us early about your power supply. Our equipment will occupy ground space on your property. You need to consider the size and

More information

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Record MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Abandoned Gravity Private Combined Gravity Private Foul Gravity Private Surface Water Gravity Public Combined Gravity Public Foul Gravity Public

More information

EAST LINDSEY DISTRICT COUNCIL ~ RESIDENTIAL CARAVAN SITES CONDITIONS OF SITE LICENCE

EAST LINDSEY DISTRICT COUNCIL ~ RESIDENTIAL CARAVAN SITES CONDITIONS OF SITE LICENCE Residential Site Licence Conditions of Licence February 2014 EAST LINDSEY DISTRICT COUNCIL ~ RESIDENTIAL CARAVAN SITES Index of conditions CONDITIONS OF SITE LICENCE 1. Period of use 2. Bases 3. Siting

More information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table

More information

SECTION 02630 STORM DRAINAGE SYSTEM

SECTION 02630 STORM DRAINAGE SYSTEM SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE

More information

6 June 2014. Document Status REVISION STATUS DATE. Initial release to industry. This Revision expired on 16 Sep. 2013.

6 June 2014. Document Status REVISION STATUS DATE. Initial release to industry. This Revision expired on 16 Sep. 2013. 6 June 2014 Document Status REVISION STATUS DATE REV 0 Initial release to industry. This Revision expired on 16 Sep. 2013 6 Sep 2013 REV 1 Draft submission to ESDD 16 Sep 2013 REV 2 Draft resubmission

More information

EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS NMP 1.4 EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS Index Purpose... 2 Application... 2 Referral Agency... 2 Associated Requirements... 2 Referenced Standards...2 Definitions...

More information

www.klmtechgroup.com TABLE OF CONTENT

www.klmtechgroup.com TABLE OF CONTENT Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia ELECTIRAL GROUNDING TABLE OF CONTENT

More information

Standard terms and conditions

Standard terms and conditions Standard terms and conditions INTRODUCTION For the provision of a water service (Water Supply, Wastewater and Drainage) Under Section 73(2)(a) of the Water Services Act 2012, landowners may be entitled

More information

CCU Engineering Specifications. Section 003300 PRECAST CONCRETE PRODUCTS

CCU Engineering Specifications. Section 003300 PRECAST CONCRETE PRODUCTS CCU Engineering Specifications Section 003300 Effective Date: Nov. 1st, 2011 Page 1 of 5 PRECAST CONCRETE PRODUCTS PART 1 - GENERAL The following specification is intended for use for the design, selection

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

Amendment to OPSS 415 (Nov 2008) Construction Specification for Pipeline and Utility Installation by Tunnelling

Amendment to OPSS 415 (Nov 2008) Construction Specification for Pipeline and Utility Installation by Tunnelling Engineering and Construction Services Division Standard Specifications for Sewers and Watermains TS 415 April 2013 Amendment to OPSS 415 (Nov 2008) Construction Specification for Pipeline and Utility Installation

More information

Location. Central Business District. Ataturk Airport IFC. Sabiha Gökçen Airport

Location. Central Business District. Ataturk Airport IFC. Sabiha Gökçen Airport Welcome Zenium Istanbul One provides 12,000 square metres of high specification technical space across three purpose-built data centers. It is Turkey s first wholesale data center offering; the data halls

More information

Morrison Bros. Co. General Product Specifications

Morrison Bros. Co. General Product Specifications Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage

More information

Devonport EfW CHP Facility. CEMP Proposal for Non Destructive Testing Activities. 1. Introduction

Devonport EfW CHP Facility. CEMP Proposal for Non Destructive Testing Activities. 1. Introduction Devonport EfW CHP Facility CEMP Proposal for Non Destructive Testing Activities. 1. Introduction This application is issued in compliance with the principles of the approved Construction Environmental

More information

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments Cannon T4 Modular Data Centres For Outside Deployment & Challenging Environments A high performance, full specification Data Centre, up to Tier 4* resilience, instantly deployable A highly secure Data

More information

PLM series Permanent load lifting magnets

PLM series Permanent load lifting magnets Lifting gear Load lifting magnets/chain hoists PLM series Permanent load lifting magnets Load-bearing capacity of up to 1 t depending on model despite light weight High standard of safety with simple lever

More information

Reticulation sewers in basements Technical guidelines

Reticulation sewers in basements Technical guidelines Reticulation sewers in basements Technical guidelines Overview What These guidelines explain our technical requirements for laying sewers in building basements. The scope of the guide is restricted to

More information

Operating Instructions

Operating Instructions VMD202 Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the VMD202 as a safety reversing or presence detection system. The VMD202 requires that a vehicle be moving for detection.

More information

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can

More information

SECTION 15410 GROUND WATER STORAGE TANKS

SECTION 15410 GROUND WATER STORAGE TANKS SECTION 15410 GROUND WATER STORAGE TANKS PART 1 GENERAL.01 SCOPE A. Section Includes Requirements for designing, fabricating, and erecting a welded steel ground storage tank..02 SYSTEM DESCRIPTION A. Design

More information

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION 1. SCOPE Pipe subsoil drains shall be constructed in accordance with this specification and in conformity with the lines, grades and cross-sections shown

More information

MOBILE HOME LAW. Revised November 2001

MOBILE HOME LAW. Revised November 2001 MOBILE HOME LAW Revised November 2001 TABLE OF CONTENTS: SECTION 1: SECTION 2: SECTION 3: SECTION 4: SECTION 5: SECTION 6: SECTION 7: SECTION 8: SECTION 9: SECTION 10: SECTION 11: SECTION 12: INTENT DEFINITIONS

More information

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

SWIMMING POOL, SPA, & HOT TUB GUIDELINES SWIMMING POOL, SPA, & HOT TUB GUIDELINES Pool permit cost is based on the total value of the project. See Permit Fee Schedule Table 1A. A. Adopted construction codes and installation requirements 1. 2015

More information

Gazeley. Where You and Your Horses Safety Comes First. Coachbuilders Ltd. Designed and Manufactured in Newmarket, Suffolk, Great Britain

Gazeley. Where You and Your Horses Safety Comes First. Coachbuilders Ltd. Designed and Manufactured in Newmarket, Suffolk, Great Britain Gazeley Coachbuilders Ltd HORSEBOX MANUFACTURER Designed and Manufactured in Newmarket, Suffolk, Great Britain Where You and Your Horses Safety Comes First Gazeley Coachbuilders Ltd is a total family business.

More information

1. Safety. 2. The Lining Contractor. DEPARTMENT OF AGRICULTURE, AND FOOD Farm Development Service November 2002 S126

1. Safety. 2. The Lining Contractor. DEPARTMENT OF AGRICULTURE, AND FOOD Farm Development Service November 2002 S126 DEPARTMENT OF AGRICULTURE, AND FOOD Farm Development Service November 2002 S126 MINIMUM SPECIFICATION FOR GEOMEMBRANE-LINED SLURRY/EFFLUENT STORES, AND ANCILLARY WORKS This is a minimum specification.

More information

Transformer Deluge Systems

Transformer Deluge Systems Transformer Deluge Systems How Do Transformer Fires Ignite? Common causes of transformer failure: Weather-related events such as lightning Short circuits in electrical equipment The most common cause is

More information

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE Multilift PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE Applicable Codes: ASME A17.1 ASME A18.1 CSA B613 CSA B355-09 19-m01-2015 Part No. 000790 Copyright 2015 Savaria Corporation All rights reserved. Printed

More information

Figure 5.6a Construction worksites and corridor access Note: Indicative only, subject to detailed design.

Figure 5.6a Construction worksites and corridor access Note: Indicative only, subject to detailed design. A 0 NORTH 200 metres George Lane worksite North Strathfield Station worksite Strath eld Triangle A B Existing rail corridor Proposed underpass approach New/extended bridge Worksites Existing track Proposed

More information

part 9 waste management

part 9 waste management part 9 waste management 30m Hammerhead T-form 22m 21m Hammerhead Y-form 30m 18m Forward Side-Turn 25m 15m Reverse Side-Turn 30m Above: Recommended turning circles for waste collection vehicles 9 WASTE

More information

Protection of unoccupied or void properties

Protection of unoccupied or void properties Real Estate Issue one Protection of unoccupied or void properties Introduction The current economic downturn has lead to a greatly increased number of vacant properties. In some countries rates of unoccupancy

More information

SECTION 22 LIGHTNING PROTECTION SYSTEM

SECTION 22 LIGHTNING PROTECTION SYSTEM SECTION 22 LIGHTNING PROTECTION SYSTEM 22.01 SCOPE: A. These Specifications shall form a part of the Contract Documents and shall govern construction work for all buildings to be built or modified for

More information

BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY

BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY MURRAY SHIRE COUNCIL BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY ADOPTED: 1 May 2012 1 BUILDING OVER OR NEAR WATER AND SEWER MAINS POLICY CONTENTS 1. Objective... 2 2. Requirements for Building Near

More information

Cooking at the Speed of light!

Cooking at the Speed of light! Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide

More information

Second Place: Industrial Facilities or Processes, New

Second Place: Industrial Facilities or Processes, New Second Place: Industrial Facilities or Processes, New Photo: Paul Howell Texas Medical Center in Houston is the largest medical center in North America. It has a chilled water system of 160,000 tons. Big

More information

Water Supply Code of Australia WSA 03 2011-3.1

Water Supply Code of Australia WSA 03 2011-3.1 Supplement to Water Supply Code of Australia Melbourne Retail Water Agencies Edition Version 2.0 This work is the property of Gippsland Water and is protected by copyright. The work and information herein

More information

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+)

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+) Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+) 1. In addition to the information scheduled below, the pre-tender designer is responsible for: (i)

More information

DISTRIBUTION CONNECTION

DISTRIBUTION CONNECTION DISTRIBUTION CONNECTION POLICY Page 1/15 TABLE OF CONTENTS 1 Introduction... 3 2 Acceptance of requests for a connection... 3 2.1 Who can request a connection... 3 2.2 How to request a connection... 4

More information

3. QUALITY ASSURANCE REQUIREMENTS

3. QUALITY ASSURANCE REQUIREMENTS 3. QUALITY ASSURANCE REQUIREMENTS 3.1 General This section covers the Kaipara District Council requirements for monitoring and testing of physical asset construction to ensure that the final asset delivered

More information

Urban Vehicle Crossing Application To be completed and fees paid for prior to approval

Urban Vehicle Crossing Application To be completed and fees paid for prior to approval Urban Vehicle Crossing Application To be completed and fees paid for prior to approval Applicant Details Name: Postal Address: Telephone Home: Work: Signed: Date: Proposed Contractor: Proposed Start Date:

More information

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair The Concept A Europe-wide research and development programme identified the need for a high performance cassette fan convector, powered by low pressure hot water and compatible with universal suspended

More information

Residential Driveway Installation Requirements. Table of Contents

Residential Driveway Installation Requirements. Table of Contents Residential Driveway Installation Requirements Table of Contents Residential Driveway Requirements Sidewalk Construction Specifications for Residential Properties Hold Harmless Agreement for Residential

More information

Certificate of Registration

Certificate of Registration Certificate of Registration This is to certify that Clancy Docwra Limited Supplier Number: 061973 are now fully registered as a supplier on UVDB for the following products/services 1.4.25 Communication

More information

Operating Instructions

Operating Instructions CS101 CarSense Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the CS101 as a safety reversing or presence detection system. The CS101 requires that a vehicle be moving for

More information

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT Page 1 CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT CIVIC CENTRE 2141 MAJOR MACKENZIE DRIVE MAPLE ONTARIO L6A 1T1 905-832-2281 Page 2 SECTION 1 - GENERAL OBJECTIVES To provide

More information

Force Main Condition Assessment: New Technologies & Case Studies

Force Main Condition Assessment: New Technologies & Case Studies Force Main Condition Assessment: New Technologies & Case Studies Andy Dettmer, Ph.D., P.E. CMOM Workshop August 19, 2014 2 1 Three takeaways 1. Most of your force mains are good 2. We can pinpoint the

More information

DESIGN STANDARDS PINE RIVERS SHIRE COUNCIL. Design Standards for Sewerage Works DESIGN MANUAL CIVIL INFRASTRUCTURE DESIGN

DESIGN STANDARDS PINE RIVERS SHIRE COUNCIL. Design Standards for Sewerage Works DESIGN MANUAL CIVIL INFRASTRUCTURE DESIGN PINE RIVERS SHIRE COUNCIL DESIGN MANUAL CIVIL INFRASTRUCTURE DESIGN DESIGN STANDARDS Part 1 Part 2 Part 3 Part 4 Design Standards for Roadworks Design Standards for Stormwater Drainage Works Design Standards

More information

1.1 DIMENSIONS AND WEIGHT PAG. 2 1.2 LOAD CENTRE FOR LIFTING PAG. 2 1.3 STORAGE CONDITIONS PAG. 2

1.1 DIMENSIONS AND WEIGHT PAG. 2 1.2 LOAD CENTRE FOR LIFTING PAG. 2 1.3 STORAGE CONDITIONS PAG. 2 TRANSPORT AND INSTALLATION. DIMENSIONS AND WEIGHT PAG.. LOAD CENTRE FOR LIFTING PAG..3 STORAGE CONDITIONS PAG. STARTING. INSTALLATION PAG.. SPACE REQUIREMENTS PAG. 3.3 ELECTRIC CONNECTION PAG. 3 3 DESCRIPTION

More information

REAL ESTATE DESCRIPTION

REAL ESTATE DESCRIPTION REAL ESTATE DESCRIPTION #51 SZIGETVÁR JÓZSEF ATTILA U. 27-31. Id. No.: 592 The Property Appraised Neighborhood Description The subject property is located in the center of the settlement of Szigetvár,

More information

Power consumption (kw)

Power consumption (kw) OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components

More information

Waste Management. GUIDANCE NOTES FOR DEVELOPERS AND LANDLORDS ON THE STORAGE & COLLECTION OF DOMESTIC REFUSE AND RECYCLING (December 2012)

Waste Management. GUIDANCE NOTES FOR DEVELOPERS AND LANDLORDS ON THE STORAGE & COLLECTION OF DOMESTIC REFUSE AND RECYCLING (December 2012) Waste Management GUIDANCE NOTES FOR DEVELOPERS AND LANDLORDS ON THE STORAGE & COLLECTION OF DOMESTIC REFUSE AND RECYCLING (December 2012) 1. Introduction The aim of this guide is to inform developers of

More information

Refuse and Recycling Advice note For Developers. September 2015

Refuse and Recycling Advice note For Developers. September 2015 Refuse and Recycling Advice note For Developers Contents: September 2015 1.0 Refuse and recycling Background Information 1.1 Introduction 2.0 Planning and design 2.1 Good Practice 2.2 Internal storage

More information

2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS

2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS 2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS Water system improvements proposed for inclusion into Western s service area shall be designed in accordance with all appropriate AWWA standards, include

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

For business. Wiring your business for broadband. What happens when copper is required?

For business. Wiring your business for broadband. What happens when copper is required? For business Wiring your business for broadband Your cabling requirements are dependent on the size and complexity of your business. Smaller businesses should follow the wiring recommendations for residential

More information

CITY OF VINCENT CONSTRUCTION MANAGEMENT PLAN GUIDELINES

CITY OF VINCENT CONSTRUCTION MANAGEMENT PLAN GUIDELINES CITY OF VINCENT CONSTRUCTION MANAGEMENT PLAN GUIDELINES INTRODUCTION What is a Construction Management Plan? The City of Vincent requires careful management of construction involving excavation and retention

More information

Element D Services Plumbing

Element D Services Plumbing Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.

More information

Appendix A: Acceptable pipe and fitting materials

Appendix A: Acceptable pipe and fitting materials Watercare Services Limited Water and Code of Practice Content from the NZS 4404:2010 Land development and subdivision infrastructure has been reproduced for use in the Infrastructure Design s Manual for

More information

Hyperlinks are Inactive

Hyperlinks are Inactive Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD)

More information

Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development

Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development 7 SPECIFICATIONS There is currently no Irish specification for construction of drainage works, or water supply works. There are several publications that give guidance on drainage works, such as the Building

More information

89 Avenue Road GP Ltd. Functional Servicing and Stormwater Management Report for 89 Avenue Road Re-Development City of Toronto

89 Avenue Road GP Ltd. Functional Servicing and Stormwater Management Report for 89 Avenue Road Re-Development City of Toronto 89 Avenue Road GP Ltd. Functional Servicing and Stormwater Management Report for 89 Avenue Road Re-Development City of Toronto Prepared By: R.J. Burnside & Associates Limited 6990 Creditview Road, Unit

More information

Standard Specification for the Laying of Sewer Lines and Appurtenances in the Hurunui District

Standard Specification for the Laying of Sewer Lines and Appurtenances in the Hurunui District Standard Specification for the Laying of Sewer Lines and Appurtenances in the Hurunui District 1. SCOPE OF WORK This Specification applies to the laying of sewer pipes and all associated appurtenances

More information

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel

More information

Electrical Service Guidelines

Electrical Service Guidelines Electrical Service Guidelines Middle Tennessee Electric Membership Corporation Revised: May 23, 2013 MTEMC's Electrical Guidelines TABLE OF CONTENTS Right-of-Way Clearance Guide 3 MTEMC Requirements 4

More information

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project: PLATE HEAT EXCHANGER Installation Manual Customer Name: Serial number: Purchase order number: Project: Table of Contents ----------------------------------------------------------------- Page: 2 3 Name

More information

21.1 Functions, Basic Configuration, and Interfaces

21.1 Functions, Basic Configuration, and Interfaces 21 (6.2.M) Site Services Building 21.1 Functions, Basic Configuration, and Interfaces 21.1.1 Functions The primary functions performed by the site services building are to house, support, provide a suitable

More information

TG 105 ALLOWABLE PIPE SIZE, CLASS AND MATERIALS FOR WATER MAINS TECHNICAL GUIDELINE. Manager Asset Management SOUTH AUSTRALIAN WATER CORPORATION

TG 105 ALLOWABLE PIPE SIZE, CLASS AND MATERIALS FOR WATER MAINS TECHNICAL GUIDELINE. Manager Asset Management SOUTH AUSTRALIAN WATER CORPORATION TG 105 SOUTH AUSTRALIAN WATER CORPORATION TECHNICAL GUIDELINE ALLOWABLE PIPE SIZE, CLASS AND MATERIALS FOR WATER MAINS Issued by: Manager Asset Management Issue Date: SA WATER 2007 This document is copyright

More information

Engineered Material Handling. Overhead Bridge Cranes and Gantry Cranes

Engineered Material Handling. Overhead Bridge Cranes and Gantry Cranes TM Engineered Material Handling Overhead Bridge Overhead and Gantry Bridge Cranes and Gantry Cranes Custom Engineered Crane Systems Gantry Cranes EMH builds a complete range of gantry cranes including

More information

SECTION 2.7 - SEWERAGE AND COMMON EFFLUENT DISPOSAL (CED) RETICULATION

SECTION 2.7 - SEWERAGE AND COMMON EFFLUENT DISPOSAL (CED) RETICULATION Ref: 27REVB20050131.DOC Date: 31 Jan 2005 Issue: B SECTION 2.7 - SEWERAGE AND COMMON EFFLUENT DISPOSAL (CED) RETICULATION PURPOSE OF SECTION 2.7.1 GENERAL 2.7.2 PRELIMINARY SEWER CONCEPT PLAN 2.7.3 TRUNK

More information

Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009

Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009 Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009 By Carsten Palle, VID Fire-Fill, www.vid.eu Presented at ISTSS

More information

Guidance on applying for approval of installation of a commercial onsite wastewater system

Guidance on applying for approval of installation of a commercial onsite wastewater system Guidance on applying for approval of installation of a commercial onsite wastewater system This factsheet is designed to assist you to complete an Application to construct or install an apparatus for the

More information

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

EARTHING AND BONDING AT SECONDARY SUBSTATIONS DISTRIBUTION CONSTRUCTION MANUAL SECTION 4 - SUBSTATIONS ISSUE B SEPT 1996 4.4.4 EARTHING AND BONDING AT SECONDARY SUBSTATIONS 1 SCOPE This section of the Distribution Construction Manual lays down the

More information

INSTALLATION AND START UP REPORT CERTIFYING THE CORRECT FUNCTIONALITY OF THE AD HOC REFUELLING STATION LIFE+ MHYBUS LIFE 07-ENV/IT/000434

INSTALLATION AND START UP REPORT CERTIFYING THE CORRECT FUNCTIONALITY OF THE AD HOC REFUELLING STATION LIFE+ MHYBUS LIFE 07-ENV/IT/000434 Feb. 15, 212 Sheet: 1 of 27 INSTALLATION AND START UP REPORT CERTIFYING THE CORRECT FUNCTIONALITY OF THE AD HOC REFUELLING STATION Ref. Number: LIFE+ MHYBUS LIFE 7-ENV/IT/434 Project Acronym: MHYBUS Project

More information

Sample Micro Hydro Initial Report

Sample Micro Hydro Initial Report Sample Micro Hydro Initial Report Sample Micro Hydro Initial Report Introduction The Hydro Burn at Glen Water was visited by Richard Haworth of Glen Hydro to assess its suitability for a micro hydro installation.

More information

Waste & Recycling. Planning Guidance on Waste & Recycling Storage and Collection. Development & Enterprise FOR INTERNAL USE ONLY.

Waste & Recycling. Planning Guidance on Waste & Recycling Storage and Collection. Development & Enterprise FOR INTERNAL USE ONLY. Waste & Recycling Planning Guidance on Waste & Recycling Storage and Collection October 2011 Development & Enterprise FOR INTERNAL USE ONLY Contents 01 Introduction 3 02 General guidelines 3 03 Individual

More information

SECTION 31 20 00 EARTH MOVING

SECTION 31 20 00 EARTH MOVING SECTION 31 20 00 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section describes the requirements for excavating, filling, and grading for earthwork at Parking Structure, new exit stair and as required to

More information

Application for electricity connections Business premises. Electricity. Send your completed application form with supporting documentation to:

Application for electricity connections Business premises. Electricity. Send your completed application form with supporting documentation to: Electricity Thank you for considering for your electricity connections. We have put together these notes to help you fill out your and to ensure we receive all the correct information for your application

More information

Engineering Standard

Engineering Standard Public Transport Services Engineering Standard Stations - Bicycle Facilities PART 129013 AR-PW-PM-SPE-00129013 (D073) Document Control Document Status Document Amendment Record Revision Change Description

More information

APPLICATION FOR PLANNING PERMISSION FOR A SOIL TREATMENT FACILITY AT KINGS CLIFFE LANDFILL SITE, STAMFORD, NORTHAMPTONSHIRE

APPLICATION FOR PLANNING PERMISSION FOR A SOIL TREATMENT FACILITY AT KINGS CLIFFE LANDFILL SITE, STAMFORD, NORTHAMPTONSHIRE APPLICATION FOR PLANNING PERMISSION FOR A SOIL TREATMENT FACILITY AT KINGS CLIFFE LANDFILL SITE, STAMFORD, NORTHAMPTONSHIRE DESIGN AND ACCESS STATEMENT Report Reference: AU/KC/SPH/1449/01/D&A/FIN Baddesley

More information

Terms of Reference. Aqaba Water and Wastewater Utility Asset Valuation

Terms of Reference. Aqaba Water and Wastewater Utility Asset Valuation Technical Support for Procurement and Project Management and Private Sector Participation to the Ministry of Water and Irrigation, Water Authority of Jordan and the Jordan Valley Authority Support for

More information

ACO Water Management: Civils + Infrastructure

ACO Water Management: Civils + Infrastructure ACO Water Management: Civils + Infrastructure Technical data Introduction to The unit provides an aesthetically pleasing solution when linking proprietary conveyance drainage systems to vegetated infiltration

More information

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm: Page 1 of 6 Section 1. PURPOSE This policy is an Engineering checklist of the Local Review Program for sanitary sewer improvement projects by the Bedford Regional Water Authority ( Authority ). Section

More information

SAFE HANDLING OF PRECAST CONCRETE PRODUCTS

SAFE HANDLING OF PRECAST CONCRETE PRODUCTS SAFE HANDLING OF PRECAST CONCRETE PRODUCTS Safety Handling of Precast Concrete Products The lifting of any precast product requires the use of special equipment and substantial planning and knowledge.

More information

Melbourne Survey T 9869 0813 F 9869 0901

Melbourne Survey T 9869 0813 F 9869 0901 Melbourne Survey T 9869 081 F 9869 0901 COPERNICUS CIRCUIT SEE SHEET CENTRAL PARKWAY 5019 508 SEE SHEET 50 SEE SHEET 4 HARVARD STREET STANFORD STREET Melbourne Survey T 9869 081 F 9869 0901 No.1 5 57 No.

More information

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES 4121 N.W. 37 th Street, Lincoln, NE 68524 Telephone (402) 470-2627 Fax (404) 470-2410 www.gtexhaust.com

More information

Underground Commercial Electric Service

Underground Commercial Electric Service Underground Commercial Electric Service SCANA Corporation 2013 Revised: June 2013 Table of Contents SECTION PAGE I. Specification and Requirements 2 A. General B. Definition of Terms C. Company and Developer

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

- 33 - This paper describes an instrumentation system concept which should be capable of early detection of a leak-before* break in main steam lines.

- 33 - This paper describes an instrumentation system concept which should be capable of early detection of a leak-before* break in main steam lines. - 33 - DETECTION OF LEAKS IN STEAM LINES BY DISTRIBUTED FIBRE-OPTIC TEMPERATURE SENSING (DTS) Author; Neil G.Craik, Nuclear Generation Consultant, Frederic ton, N.B., Canada ABSTRACT This paper describes

More information

SECTION 807 PUMP STATION REHABILITATION

SECTION 807 PUMP STATION REHABILITATION SECTION 807 PUMP STATION REHABILITATION 807-1 DESCRIPTION: Rehabilitation of pump stations shall be defined as the cleaning, removal, repair and/or replacement of any and/or all components including but

More information

WATER SERVICES ASSOCIATION OF AUSTRALIA WATER SUPPLY CODE OF AUSTRALIA

WATER SERVICES ASSOCIATION OF AUSTRALIA WATER SUPPLY CODE OF AUSTRALIA WATER SERVICES ASSOCIATION OF AUSTRALIA WATER SUPPLY CODE OF AUSTRALIA WSA 03 2011 Water Supply Code of Australia WSA 03 2011 Third Edition Version 3.1 Previous edition WSA 03: 2002-2.3 CONTENTS PREFACE

More information

Home Inspection Report

Home Inspection Report 4949 Brownsboro Rd Suite 293 Louisville, KY 40223 (502) 414-1440 tripleainspections@gmail.com Inspected By: William Carter, HI-1956 Home Inspection Report Prepared For: Edward Cullen Property Address:

More information

PREFERRED REQUIREMENTS: WATER SUPPLIES AND ACCESS FOR SUBDIVISIONS IN RURAL ZONES

PREFERRED REQUIREMENTS: WATER SUPPLIES AND ACCESS FOR SUBDIVISIONS IN RURAL ZONES PREFERRED REQUIREMENTS: WATER SUPPLIES AND ACCESS FOR SUBDIVISIONS IN RURAL ZONES NOVEMBER 2006 1 TABLE OF CONTENTS Glossary of Terms 3 Introduction 4 Where Do These Guidelines Apply? 6 Statutory Requirements

More information

Responding to the challenges

Responding to the challenges WATER PROOFING THE WEST STAGE ONE MOVING TOWARDS A WATER SENSITIVE CITY Adrian Sykes Strategic Infrastructure Executive Officer, City of Charles Sturt Woodville, Adelaide, South Australia Abstract This

More information

INTERIM WASTE STORE OPERATING LICENCE DESCRIPTION OF THE STRUCTURES, COMPONENTS, SYSTEMS AND EQUIPMENT

INTERIM WASTE STORE OPERATING LICENCE DESCRIPTION OF THE STRUCTURES, COMPONENTS, SYSTEMS AND EQUIPMENT Interim Waste Store Operating Licence Application Document IWS-O-LA-FD (REDACTED VERSION) INTERIM WASTE STORE OPERATING LICENCE DESCRIPTION OF THE STRUCTURES, COMPONENTS, SYSTEMS AND EQUIPMENT (Rev. 1)

More information