SITRANS T measuring instruments for temperature
|
|
|
- Thomasine Tate
- 9 years ago
- Views:
Transcription
1 SITRANS T measuring instruments for temperature /2 Product overview Transmitters for mounting in sensor head /4 SITRANS TH100, two-wire system (Pt100) /7 SITRANS TH200, two-wire system universal /1 SITRANS TH00, two-wire system universal, HART /19 SITRANS TH400, fieldbus transmitter Transmitters for rail mounting /24 SITRANS TR200, two-wire system universal /0 SITRANS TR00, two-wire system universal, HART Transmitter for field mounting with temperature sensor /6 SITRANS TF2, Digital display thermometer /9 SITRANS TF280, WirelessHART /44 SITRANS TF, two-wire system /51 SITRANS TF, fieldbus transmitter Field indicator /44 SITRANS TF, Field indicator for 4 to 20 ma You can download all instructions, catalogs and certificates for SITRANS T free of charge at the following Internet address: Siemens FI US Edition
2 SITRANS T Measuring instruments for temperature Product overview Overview Application Mounting of transmitter with Ex protection Page Software for parameterization Transmitters for temperature for mounting in sensor heads Transmitter Sensor SITRANS TH100 Transmitters for Pt100 Mounting in sensor head Zone 2, zone 1 Zone 2, zone 1, zone 0 /4 SIPROM T SITRANS TH200 Transmitters for connection to resistance thermometers, resistance-based sensors, thermocouples and DC voltages up to 1.1 V Two-wire system Zone 2, zone 1 Zone 2, zone 1, zone 0 /7 SIPROM T Universal SITRANS TH00 Transmitters for connection to resistance thermometers, resistance-based sensors, thermocouples and DC voltages up to 1.1 V Zone 2, zone 1 Zone 2, zone 1, zone 0 /1 SIMATIC PDM Two-wire system Universal HART SITRANS TH400 Transmitters for connection to resistance thermometers, resistance-based sensors, thermocouples and DC voltages up to 0.9 V Fieldbus transmitter PROFIBUS PA FOUNDATION Fieldbus Zone 2, zone 1, zone 21 Zone 2, zone 1, zone 0, zone 21, zone 20 /19 SIMATIC PDM for TH 400 with PROFIBUS PA Transmitters for temperature for rail mounting SITRANS TR200 Transmitters for connection to resistance thermometers, resistance-based sensors, thermocouples and DC voltages up to 1.1 V Zone 2, zone 1, zone 21 Zone 2, zone 1, zone 0, zone 21, zone 20 /24 SIPROM T Two-wire system Universal SITRANS TR00 Transmitters for connection to resistance thermometers, resistance-based sensors, thermocouples and DC voltages up to 1.1 V Zone 2, zone 1, zone 21 Zone 2, zone 1, zone 0, zone 21, zone 20 /0 SIMATIC PDM Two-wire system Universal, HART /2 Siemens FI US Edition
3 SITRANS T Measuring instruments for temperature Product overview Application Transmitter for temperature for field mounting SITRANS TF2 Digital display thermometer Transmitter with LCD display and mounted Pt100 Mounting of transmitter with Ex protection Transmitter Sensor Page Software for parameterization - - /6 Local programming using keys SITRANS TF280 Transmitters for connection to resistance-based sensors In field housing for heavy industrial use Battery power supply WirelessHART - - /9 SIMATIC PDM via WirelessHART SIMATIC PDM local with HARTmodem Local programming using push buttons SITRANS TF Transmitters for connection to resistance thermometers, resistance-based sensors, thermocouples and DC voltages up to 1.1 V In field housing for heavy industrial use Zone 2, zone 1 Zone 2, zone 1, zone 0 /44 Depends on mounted transmitter TH200/TH00 SITRANS TF Fieldbus transmitters for connection to resistance thermometers, resistance-based sensors, thermocouples and DC voltages up to 0.8 V In field enclosure for heavy industrial use PROFIBUS PA FOUNDATION fieldbus Field indicator for 4 to 20 ma signals SITRANS TF Field indicator for 4 to 20 ma signals Display of units can be userdefined Zone 2, Zone 1 Zone 2, zone 1 Zone 2, Zone 1, Zone 0 - /44 - /51 SIMATIC PDM for PROFIBUS PA Siemens FI US Edition /
4 Transmittters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) Overview Application Used in conjunction with Pt100 resistance thermometers, the SITRANS TH100 transmitters are ideal for measuring temperatures in all industries. Due to its compact size it can be installed in the connection head type B (DIN 4729) or larger. The output signal is a direct current from 4 to 20 ma that is proportional to the temperature. Parameterization is implemented over the PC using the parameterization software SIPROM T and the modem for SITRANS TH100/TH200. If you already have a "modem for SITRANS TK" (Order No. 7NG190-6KB), you can continue using this to parameterize the SITRANS TH100. Transmitters of the "intrinsically-safe" type of protection can be installed within potentially explosive atmospheres. The devices comply with the Directive 94/9/EC (ATEX), as well as FM and CSA regulations. The SITRANS TH100 dispenses with electrical isolation and universal sensor connection to provide a low-cost alternative for Pt100 measurements. For the parameterization, the SIPROM T software is used in combination with the modem for SITRANS TH100/TH200. Its extremely compact design makes the SITRANS TH100 ideal for the retrofitting of measuring points or for the use of analog transmitters. The transmitter is available as a non-ex version as well as for use in potentially explosive atmospheres. Benefits Two-wire transmitter Assembly in connection head type B (DIN 4729) or larger, or on a standard DIN rail Can be programmed, which means that the sensor connection, measuring range, etc. can also be programmed Intrinsically-safe version for use in potentially explosive areas Function Mode of operation The measured signal supplied by a Pt100 resistance thermometer (2, or 4-wire system) is amplified in the input stage. The voltage, which is proportional to the input variable, is then converted into digital signals by a multiplexer in an analog/digital converter. They are converted in the microcontroller in accordance with the sensor characteristics and further parameters (measuring range, damping, ambient temperature etc.). The signal prepared in this way is converted in a digital/analog converter into a load-independent direct current of 4 to 20 ma. An EMC filter protects the input and output circuits against electromagnetic interferences. 6 I c U ref Input Pt100 EMC_1 IC MUX A/D Resistance thermometer Input level with protective components Constant current source Multiplexer Analog-digital converter Pt EMC_1 MUX U ref A/D D/A μc Output D/A U/I EMC_2 U aux I out Digital-analog converter Voltage transformers, current transformers, constant voltage and reference voltage source Output level with protective components Auxiliary power supply Output current Microcontroller μc Linearization functions and storage of all data +1 U I EMC_ ma -2 U aux, I out SITRANS TH100, function diagram /4 Siemens FI US Edition
5 Transmittters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) Technical specifications Certificate and approvals Input Explosion protection ATEX Resistance thermometer EC type test certificate PTB 05 ATEX 2049X Measured variable Temperature Intrinsically-safe" type of protection II 1G EEx ia IIC T6/T4 II 2(1)G EEx ia/ib IIC T6/T4 Sensor type Pt100 to IEC Characteristic Temperature-linear Operating equipment that is nonignitable and has limited energy II G EEx nal IIC T6/T4 Type of connection 2, or 4-wire circuit type of protection Resolution 14 bit Explosion protection to FM for USA Measuring accuracy and Canada ( c FM US ) Span < 250 C (450 F) < 0.25 C (0.45 F) FM approval PID Span > 250 C (450 F) < 0.1 % of span Degree of protection IS/Cl I, II, III/Div 1/GP ABCDEFG Repeatability < 0.1 C (0.18 F) T4, T5, T6 IS/Cl I/ZN 0, 1/AEx ia IIC T4, T5, T6 Measuring current approx. 0.4 ma NI/Cl I, II, III/Div 2/GP ABCDFG T4, Measuring cycle < 0.7 s T5, T6 Range C Cl I/ZN 2/GP IIC T4,T5,T6 ( F) Softw. requirements for SIPROM T Measured span C ( F) PC operating system Windows ME, 2000 and XP; Unit C or F also Windows 95, 98 and 98SE, Offset but only in connection with programmable: RS-22 modem C ( F) Line resistance Max. 20 Ω (total from feeder and return conductor) Selection and Ordering data Order-No. Noise rejection 50 and 60 Hz SITRANS TH100 temp. transmitters for Pt100 Output For installation in the connection head, Type B (DIN 4729). Two-wire system ma, programmable, Output signal ma, two-wire without electrical isolation Without explosion protection } C) 7NG211-0NN00 Power supply V DC (0 V for Ex) With explosion protection, Max. load (U aux V)/0.02 A "Intrinsic safety" and for zone 2 Overrange ma, continuously adjustable - to ATEX } C) 7NG211-0AN00 (default value: ma) - to FM ( c FM US ) } C) 7NG211-0BN00 Error signal (in the event of sensor Further designs Order code breakage) ma, continuously adjustable (default value:.6 ma or 22.8 ma) Damping time s (default value: 0 s) Protection Against reversed polarity Resolution 12 bit Accuracy at 2 C (7.4 F) < 0.1 % of span Temperature effect < 0.1 %/10 C (0.1 %/18 F) Effect of auxiliary power < 0.01 % of span/v Effect of load impedance < % of max. span/100 Long-term drift in the first month < % of max. span after one year < 0.05 % of max. span after 5 years < 0.05 % of max. span Ambient temperature Ambient temperature range C ( F) Storage temperature range C ( F) Relative humidity 98 %, with condensation Electromagnetic compatibility According to EN 6126 and NAMUR NE21 Design Approx. weight 50 g Dimensions See dimension drawing Material Molded plastic Cross-section of cables Max. 2.5 mm 2 (AWG 1) Degree of protection to EN Enclosure IP40 Terminals IP00 Please add "-Z" to Order No. and specify Order code(s) Customer-defined operating data Y01 1) Test protocol (5 measuring points) C11 Accessories Order-No. Modem for SITRANS TH100 and TH200 incl. SIPROM T parameterization software with USB connection } C) 7NG092-8KU with RS 22 connection } C) 7NG092-8KM CD for meas. instruments for temperature A5E With documentation in German, English, French, Spanish, Italian, Portuguese and SIPROM T parameterization software DIN rail adapters for head transmitters } 7NG092-8KA (Quantity delivered: 5 units) 4-wire connection cable 7NG092-8KC 150 mm, for sensor connections when using head transmitters in the high hinged cover (set with 5 units) } Available ex stock. 1) Y01: Please specify all data that does not correspond to factory settings (see below). C) Subject to export regulations AL: N, ECCN: EAR99. Power supply units see "SITRANS I supply units and input isolators". Factory setting: Pt100 (IEC 751) with three-wire circuit Measuring range: C ( F) Error signal in the event of sensor breakage: 22.8 ma Sensor offset: 0 C (0 F) Damping 0.0 s Siemens FI US Edition /5
6 Transmittters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) Dimensional drawings Siemens AG 2010 Mounting on DIN rail 20,8 (0.82) 44 (1.7) Internal diameter Center hole 6. (0.25) Mounting screw M4x25 SITRANS TH100, mounting of transmitter on DIN rail 14 (0.55) 50,5 (1.99) (1.0) (1.) 1(+) and 2(-) Auxiliary power supply U aux, output current I Out, 4, 5 and 6 Pt100 sensor (for connection, see Sensor connection assignment) 59,6 (2.5) SITRANS TH100, dimensions in mm (inch) Schematics DIN rail adaptor, dimensions in mm (inch) Two-wire system (parameterizable line resistance) Three-wire system U aux + - Four-wire system Connection of auxiliary power supply (U aux ) SITRANS TH100, sensor connection assignment /6 Siemens FI US Edition
7 Overview Siemens AG 2010 Transmittters for mounting in sensor head SITRANS TH200 two-wire system, universal SIL 2 (with order code C20) Expanded diagnostic functions, such as slave pointer, operating hours counter, etc. Special characteristic Electromagnetic compatibility to EN 6126 and NE21 Ultra flexible - with the universal SITRANS TH200 transmitter Two-wire devices for 4 to 20 ma Mounting in the connection head of the temperature sensor Universal input for virtually any type of temperature sensor Configurable over PC Benefits Compact design Flexible mounting and center hole allow you to select your preferred type of installation Electrically isolated Test sockets for multimeters Diagnostics LED (green/red) Sensor monitoring open circuits and short-circuits Self-monitoring Configuration status stored in EEPROM Application SITRANS TH200 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal sources can be connected over their universal input module: Resistance thermometers (two, three or four-wire system) Thermocouple elements Resistance-based sensors and DC voltage sources The output signal is a direct current from 4 to 20 ma in accordance with the sensor characteristic. Transmitters of the "intrinsically-safe" type of protection can be installed within potentially explosive atmospheres. The devices comply with the Directive 94/9/EC (ATEX), as well as FM and CSA regulations. Function The SITRANS TH200 is configured over a PC. A USB or RS 22 modem is linked to the output terminals for this purpose. The configuration data can now be edited using the SIPROM T software tool. The configuration data are then permanently stored in the non-volatile memory (EEPROM). Once the sensors and power supply have been correctly connected, the transmitter outputs a temperature-linear output signal and the diagnostics LED displays a green light. In the case of a sensor short-circuit, the LED flashes red, an internal device fault is indicated by a steady red light. The test socket can be used to connect an ammeter at any time for monitoring purposes and plausibility checks. The output current can be read without any interruption, or even without opening the current loop. SITRANS TH200/TH00 (2) TC/RTD sensor A D μc1 (1) μc2 D A Test ma U aux, I out -2 Input A/D Sensors μc1 Analog-digital converter Resistance thermometer, thermocouple, resistance-based sensor, mv sensor Microcontroller, secondary circuit Output μc2 D/A U aux I out Microcontroller, primary circuit Digital-analog converter Auxiliary power supply Output current (1) Electrically isolated (2) LED SITRANS TH200 function diagram Siemens FI US Edition /7
8 Transmittters for mounting in sensor head SITRANS TH200 two-wire system, universal Technical specifications Input Resistance thermometer Measured variable Temperature Sensor type to IEC Pt25... Pt1000 to JIS C 1604; a = K -1 Pt25... Pt1000 to IEC Ni25... Ni1000 Special type over special characteristic (max. 0 points) Sensor factor (adaptation of the basic type, e.g. Pt100 to version Pt25... Pt1000) Units C or F Connection Standard connection 1 resistance thermometer (RTD) in 2-wire, -wire or 4-wire system Generation of average value 2 identical resistance thermometers in 2-wire system for generation of average temperature Generation of difference 2 identical resistance thermometers (RTD) in 2-wire system (RTD 1 RTD 2 or RTD 2 RTD 1) Interface Two-wire system Parameterizable line resistance 100 Ω (loop resistance) Three-wire system No balancing required Four-wire system No balancing required Sensor current 0.45 ma Response time 250 ms for 1 sensor with opencircuit monitoring Open-circuit monitoring can be switched off Short-circuit monitoring can be switched off (value is adjustable) Measuring range Parameterizable (see table "Digital measuring errors") Min. measured span 10 C (18 F) Characteristic curve Temperature-linear or special characteristic Resistance-based sensors Measured variable Actual resistance Sensor type Resistance-based, potentiometers Units Ω Connection Normal connection 1 resistance-based sensor (R) in 2-wire, -wire or 4-wire system Generation of average value 2 resistance-based sensors in 2-wire system for generation of average value Generation of difference 2 resistance thermometers in 2-wire system (R1 R2 or R2 R1) Interface Two-wire system Parameterizable line resistance 100 Ω (loop resistance) Three-wire system No balancing required Four-wire system No balancing required Sensor current 0.45 ma Response time 250 ms for 1 sensor with opencircuit monitoring Open-circuit monitoring can be switched off Short-circuit monitoring can be switched off (value is adjustable) Measuring range Parameterizable, max Ω (see Table "Digital measuring errors") Min. measured span 5 Ω Ω (see Table "Digital measuring errors") Characteristic curve Resistance-linear or special characteristic Thermocouple elements Measured variable Temperature Sensor type (thermocouples) Type B Pt0Rh-Pt6Rh to DIN IEC 584 Type C W5 %-Re to ASTM 988 Type D W %-Re to ASTM 988 Type E NiCr-CuNi to DIN IEC 584 Type J Fe-CuNi to DIN IEC 584 Type K NiCr-Ni to DIN IEC 584 Type L Fe-CuNi to DIN 4710 Type N NiCrSi-NiSi to DIN IEC 584 Type R Pt1Rh-Pt to DIN IEC 584 Type S Pt10Rh-Pt to DIN IEC 584 Type T Cu-CuNi to DIN IEC 584 Type U Cu-CuNi to DIN 4710 Units C or F Connection Standard connection 1 thermocouple element (TC) Generation of average value 2 thermocouple elements (TC) Generation of difference 2 thermocouple elements (TC) TC1 TC2 or TC2 TC1) Response time 250 ms for 1 sensor with opencircuit monitoring Open-circuit monitoring can be switched off Cold junction compensation Internal With integrated Pt100 resistance thermometer External With external Pt100 IEC (2-wire or -wire connection) External fixed Cold junction temperature can be set as fixed value Measuring range Parameterizable (see table "Digital measuring errors") Min. measured span Min C ( F) (see table "Digital measuring errors") Characteristic curve Temperature-linear or special characteristic mv sensor Measured variable DC voltage Sensor type DC voltage source (DC voltage source possible over an externally connected resistor) Units mv Response time 250 ms for 1 sensor with opencircuit monitoring Open-circuit monitoring can be switched off Short-circuit monitoring can be switched off (value is adjustable) /8 Siemens FI US Edition
9 Transmittters for mounting in sensor head SITRANS TH200 two-wire system, universal Measuring range Min. measured span Overload capability of the input Input resistance Characteristic curve Output Output signal Auxiliary power supply Max. load Overrange Error signal (e.g. in the event of sensor breakage) mv mv 2 mv or 20 mv V DC 1 MΩ Voltage-linear or special characteristic ma, 2-wire V DC (to 0 V with EEx) (U aux 11 V)/0.02 A ma, infinitely adjustable (default range:.8 ma ma) ma, infinitely adjustable (default value: 22.8 ma) Sample cycle 0.25 s nominal Damping Software filter 1st order s (parameterizable) Protection Against reversed polarity Electrically isolated Input against output (1 kv eff ) Measuring accuracy Digital measuring errors See Table "Digital measuring errors" Reference conditions Auxiliary power supply 24 V ± 1% Load 500 Ω Ambient temperature 2 C Warming-up time > 5 min Error in the analog output (digital/analog converter) < % of span Error due to internal cold junction < 0.5 C (0.9 F) Temperature effect < 0.1 % of max. span/10 C (18 F) Power supply effect < % of span/v Effect of load impedance < % of span/100 Ω Long-term drift in the first month < 0.02 % of max. span after one year < 0.2 % of max. span after 5 years < 0. % of max. span Rated conditions Ambient conditions Ambient temperature range C ( F) Storage temperature range C ( F) Relative humidity < 98 %, with condensation Electromagnetic compatibility acc. to EN 6126 and NE21 Design Material Molded plastic Weight 50 g (0.11 lb) Dimensions See "Dimensional drawings" Cross-section of cables Max. 2.5 mm² (AWG 1) Degree of protection to IEC Enclosure IP40 Terminals IP00 Certificates and approvals Explosion protection ATEX EC type test certificate PTB 05 ATEX 2040X "Intrinsic safety" type of protection II 1 G Ex ia IIC T6/T4 II 2 (1) G Ex ib/ia IIC T6/T4 "Operating equipment that is nonignitable and has limited energy" type of protection Explosion protection to FM for USA Factory setting: Pt100 (IEC 751) with three-wire circuit Measuring range: C ( F) Fault current: 22.8 ma Sensor offset: 0 C (0 F) Damping 0.0 s Digital measuring errors Resistance thermometer II G Ex nl IIC T6/T4 II G Ex na IIC T6/T4 FM approval FM Degree of protection IS/Cl I, II, III/Div 1/ GP ABCDEFG T6, T5, T4 IS/Cl I/ZN 0/AEx ia IIC T6, T5, T4 NI/Cl I, II, III/Div 2/ GP ABCDFG T6, T5, T4 NI/Cl I/ZN 2/IIC T6, T5, T4 Explosion protection to FM for Canada ( c FM US ) FM approval FM C Degree of protection IS/Cl I/ZN 0/Ex ia IIC T6, T5, T4 NI/Cl I/ZN 2/Ex nal IIC T6, T5, T4 Software requirements for SIPROM T PC operating system Windows ME, 2000 and XP; also Windows 95, 98 and 98 SE, but only in connection with RS 22 modem. Input Measuring range Min. measured span Digital accuracy C ( F) C ( F) C ( F) to IEC Pt (18) 0,2 (0.6) ( ) Pt (18) 0,15 (0.27) ( ) Pt Pt (18) 0,1 (0.18) ( ) Pt (18) 0,15 (0.27) ( ) Pt (18) 0,15 (0.27) ( ) to JIS C Pt (18) 0,2 (0.6) ( ) Pt (18) 0,15 (0.27) ( ) Pt Pt (18) 0,1 (0.18) ( ) Pt (18) 0,15 (0.27) ( ) Pt (18) 0,15 (0.27) ( ) Ni 25 to Ni ( ) 10 (18) 0,1 (0.18) Siemens FI US Edition /9
10 Transmittters for mounting in sensor head SITRANS TH200 two-wire system, universal Resistance-based sensors Selection and Ordering Data Order No. Input Measuring Min. measured Digital range span accuracy Temperature transmitter SITRANS TH200 Ω Ω Ω for installation in the connection Resistance ,05 head type B (DIN 4729) Resistance ,25 2-wire connection ma, programmable, with electrical isolation Thermocouple elements Without explosion protection } 7NG211-1NN00 Input Measuring Min. measured Digital C) range span accuracy With explosion protection C C ( F) C ( F) - acc. to ATEX } 7NG211-1AN00 ( F) C) Type B (180) 2 1) (.60) 1) - acc. to FM ( c FM US ) } 7NG211-1BN00 C) ( ) Type C (W5) (180) 2 (.60) Further designs Order code ( ) Please add "-Z" to Order No. and Type D (W) (180) 1 2) (1.80) 2) specify Order code(s) ( ) Customer-specific setting of operating Y01 1) Type E data (specify operating data (90) 1 (1.80) in plain text) ( ) Type J with test protocol (5 measuring C (90) 1 (1.80) points) ( ) Type K (90) 1 (1.80) SIL 2 (functional safety) C20 ( ) Accessories Order No. Type L (90) 1 (1.80) Modem for SITRANS TH100, ( ) TH200 and TR200 incl. Type N SIPROM T parameterization (90) 1 (1.80) software ( ) Type R With USB connection } 7NG092-8KU (180) 2 (.60) C) ( ) Type S With RS 22 connection } 7NG092-8KM (180) 2 (.60) C) ( ) Type T CD for measuring instruments } A5E (72) 1 (1.80) for temperature ( ) Type U with documentation in German, (90) 2 (.60) English, French, Spanish, Italian, ( ) Portuguese and SIPROM T parameterization software 1) The digital accuracy in the range 0 to 00 C (2 to 572 F) is C (5.4 F). 2) The digital accuracy in the range 1750 to 200 C (182 to 4172 F) is 2 C (.6 F). mv sensor Input Measuring range Min. measured span mv mv μv mv sensor mv sensor Digital accuracy The digital accuracy is the accuracy after the analog/digital conversion including linearization and calculation of the measured value. An additional error is generated in the output current 4 to 20 ma as a result of the digital/analog conversion of 0.1 % of the set span (digital-analog error). The total error under reference conditions at the analog output is the sum from the digital error and the digital-analog error (poss. with the addition of cold junction errors in the case of thermocouple measurements). Siemens AG 2010 DIN rail adapters for head } 7NG092-8KA transmitters (Quantity delivered: 5 units) 4-wire connection cable 7NG092-8KC 150 mm, for sensor connections when using head transmitters in the high hinged cover (set with 5 units) } Available ex stock. 1) Y01: Please specify all data that does not correspond to factory settings (see below). C) Subject to export regulations AL: N, ECCN: EAR99. Power supply units see "SITRANS I supply units and isolation amplifiers". Factory setting: Pt100 (IEC 751) with three-wire circuit Measuring range: C ( F) Fault current: 22.8 ma Sensor offset: 0 C (0 F) Damping 0.0 s /10 Siemens FI US Edition
11 Transmittters for mounting in sensor head SITRANS TH200 two-wire system, universal Dimensional drawings Ø 44 (1.7) Mounting on DIN rail (1.0) (1) (1) (2) (2) () (4) SITRANS TH200, mounting of transmitter on DIN rail 14 (0.55) 50,5 (1.99) (1.0) M4 x 0 26, (1.04) 59,6 (2.5) 1(+) and 2(-) Auxiliary power supply U aux, output current I Out, 4, 5 and 6 Pt100 sensor (for connections, see Sensor connection assignment) Test (+), Test (-) Measurement of the output current with a multimeter (1) Test terminal (2) Mounting screw M4x0 () LED for operation indication (4) Internal diameter of center hole 6. (0.25) DIN rail adaptor, dimensions in mm (inch) SITRANS TH200, dimensions and pin assignment, dimensions in mm (inch) Siemens FI US Edition /11
12 Transmittters for mounting in sensor head SITRANS TH200 two-wire system, universal Schematics Siemens AG 2010 Resistance thermometer Resistance Thermocouple Two-wire system 1) Two-wire system 1) Cold junction compensation Internal/fixed value Three-wire system Three-wire system Cold junction compensation with external Pt100 in two-wire system 1) Four-wire system Four-wire system Cold junction compensation with external Pt100 in three-wire system Generation of average value / difference 1) 1) Programmable line resistance for the purpose of correction. Generation of average value / difference 1) Generation of average value / difference with internal cold junction compensation Voltage measurement Current measurement Connection of auxiliary power supply (U aux ) U aux + - SITRANS TH200, sensor connection assignment /12 Siemens FI US Edition
13 Overview Siemens AG 2010 Transmittters for mounting in sensor head SITRANS TH00 two-wire system, universal, HART Application SITRANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal sources can be connected over their universal input module: Resistance thermometers (two, three or four-wire system) Thermocouple elements Resistance-based sensors and DC voltage sources The output signal is a direct current from 4 to 20 ma in accordance with the sensor characteristic, superimposed by the digital HART signal. Transmitters of the "intrinsically-safe" type of protection can be installed within potentially explosive atmospheres. The devices comply with the Directive 94/9/EC (ATEX), as well as FM and CSA regulations. "HART" to beat - the universal SITRANS TH00 transmitter Two-wire devices for 4 to 20 ma, HART Mounting in the connection head of the temperature sensor Universal input for virtually any type of temperature sensor Configurable over HART Benefits Compact design Flexible mounting and center hole allow you to select your preferred type of installation Electrically isolated Test sockets for multimeters Diagnostics LED (green/red) Sensor monitoring open circuits and short-circuits Self-monitoring Configuration status stored in EEPROM SIL 2 (with order code C20) Expanded diagnostic functions, such as slave pointer, operating hours counter, etc. Special characteristic Electromagnetic compatibility to EN 6126 and NE21 Function The SITRANS TH00 is configured over HART. This can be done using a handheld communicator or even more conveniently with a HART modem and the SIMATIC PDM parameterization software. The configuration data are then permanently stored in the non-volatile memory (EEPROM). Once the sensors and power supply have been correctly connected, the transmitter outputs a temperature-linear output signal and the diagnostics LED displays a green light. In the case of a sensor short-circuit, the LED flashes red, an internal device fault is indicated by a steady red light. The test socket can be used to connect an ammeter at any time for monitoring purposes and plausibility checks. The output current can be read without any interruption, or even without opening the current loop. SITRANS TH200/TH00 (2) TC/RTD sensor A D μc1 (1) μc2 D A Test ma U aux, I out -2 Input A/D Sensors μc1 Analog-digital converter Resistance thermometer, thermocouple, resistance-based sensor, mv sensor Microcontroller, secondary circuit Output μc2 D/A U aux I out Microcontroller, primary circuit Digital-analog converter Auxiliary power supply Output current (1) Electrically isolated (2) LED SITRANS TH 00 function diagram Siemens FI US Edition /1
14 Transmittters for mounting in sensor head SITRANS TH00 two-wire system, universal, HART Technical specifications Input Resistance thermometer Measured variable Temperature Sensor type to IEC Pt25... Pt1000 to JIS C 1604; a = K -1 Pt25... Pt1000 to IEC Ni25... Ni1000 Special type over special characteristic (max. 0 points) Sensor factor (adaptation of the basic type, e.g. Pt100 to version Pt25... Pt1000) Units C or F Connection Standard connection 1 resistance thermometer (RTD) in 2-wire, -wire or 4-wire system Generation of average value 2 identical resistance thermometers in 2-wire system for generation of average temperature Generation of difference 2 identical resistance thermometers (RTD) in 2-wire system (RTD 1 RTD 2 or RTD 2 RTD 1) Interface Two-wire system Parameterizable line resistance 100 Ω (loop resistance) Three-wire system No balancing required Four-wire system No balancing required Sensor current 0.45 ma Response time 250 ms for 1 sensor with opencircuit monitoring Open-circuit monitoring can be switched off Short-circuit monitoring can be switched off (value is adjustable) Measuring range Parameterizable (see table "Digital measuring errors") Min. measured span 10 C (18 F) Characteristic curve Temperature-linear or special characteristic Resistance-based sensors Measured variable Actual resistance Sensor type Resistance-based, potentiometers Units Ω Connection Normal connection 1 resistance-based sensor (R) in 2-wire, -wire or 4-wire system Generation of average value 2 resistance-based sensors in 2-wire system for generation of average value Generation of difference 2 resistance thermometers in 2-wire system (R1 R2 or R2 R1) Interface Two-wire system Parameterizable line resistance 100 Ω (loop resistance) Three-wire system No balancing required Four-wire system No balancing required Sensor current 0.45 ma Response time 250 ms for 1 sensor with opencircuit monitoring Open-circuit monitoring can be switched off Short-circuit monitoring can be switched off (value is adjustable) Measuring range Parameterizable, max Ω (see Table "Digital measuring errors") Min. measured span Ω (see Table "Digital measuring errors") Characteristic curve Resistance-linear or special characteristic Thermocouples Measured variable Temperature Sensor type (thermocouples) Type B Pt0Rh-Pt6Rh to DIN IEC 584 Type C W5 %-Re to ASTM 988 Type D W %-Re to ASTM 988 Type E NiCr-CuNi to DIN IEC 584 Type J Fe-CuNi to DIN IEC 584 Type K NiCr-Ni to DIN IEC 584 Type L Fe-CuNi to DIN 4710 Type N NiCrSi-NiSi to DIN IEC 584 Type R Pt1Rh-Pt to DIN IEC 584 Type S Pt10Rh-Pt to DIN IEC 584 Type T Cu-CuNi to DIN IEC 584 Type U Cu-CuNi to DIN 4710 Units C or F Connection Standard connection 1 thermocouple (TC) Generation of average value 2 thermocouples (TC) Generation of difference 2 thermocouples (TC) TC1 TC2 or TC2 TC1) Response time 250 ms for 1 sensor with opencircuit monitoring Open-circuit monitoring can be switched off Cold junction compensation Internal With integrated Pt100 resistance thermometer External With external Pt100 IEC (2-wire or -wire connection) External fixed Cold junction temperature can be set as fixed value Measuring range Parameterizable (see table "Digital measuring errors") Min. measured span Min C ( F) (see table "Digital measuring errors") Characteristic curve Temperature-linear or special characteristic mv sensor Measured variable DC voltage Sensor type DC voltage source (DC voltage source possible over an externally connected resistor) Units mv Response time 250 ms for 1 sensor with opencircuit monitoring Open-circuit monitoring can be switched off /14 Siemens FI US Edition
15 Transmittters for mounting in sensor head SITRANS TH00 two-wire system, universal, HART Short-circuit monitoring Measuring range Min. measured span Overload capacity of the input Input resistance Characteristic curve Output Output signal Auxiliary power supply Max. load Overrange Error signal (e.g. in the event of sensor breakage) Sample cycle Damping can be switched off (value is adjustable) mv mv 2 mv or 20 mv V DC 1 MΩ Voltage-linear or special characteristic ma, 2-wire with communication to HART Rev V DC (to 0 V with EEx) (U aux 11 V)/0.02 A ma, continuously adjustable (default range:.8 ma ma) ma, continuously adjustable (default value: 22.8 ma) 0.25 s nominal Software filter 1st order s (parameterizable) Against reversed polarity Protection Electrically isolated Input against output (1 kv eff ) Measuring accuracy Digital measuring errors See Table "Digital measuring errors" Reference conditions Auxiliary power supply 24 V ± 1% Load 500 Ω Storage temperature 2 C Warming-up time > 5 min Error in the analog output < % of span (digital/analog converter) Error due to internal cold junction < 0.5 C (0.9 F) Temperature effect < 0.1 % of max. span/10 C (18 F) Power supply effect < % of span/v Effect of load impedance < % of span/100 Ω Long-term drift in the first month < 0.02 % of max. span after one year < 0.2 % of max. span after 5 years < 0. % of max. span Rated conditions Ambient temperature Ambient temperature range C ( F) Storage temperature range C ( F) Relative humidity < 98 %, with condensation Electromagnetic compatibility acc. to EN 6126 and NE21 Construction Material Molded plastic Weight 50 g (0.11 lb) Dimensions See "Dimensional drawings" Cross-section of cables Max. 2.5 mm² (AWG 1) Degree of protection to IEC Enclosure IP40 Terminals IP00 Certificate and approvals Explosion protection ATEX EC type test certificate PTB 05 ATEX 2040X "Intrinsic safety" type of II 1 G Ex ia IIC T6/T4 protection II 2 (1) G Ex ib/ia IIC T6/T4 "Operating equipment that is II G Ex nl IIC T6/T4 non-ignitable and has limited II G Ex na IIC T6/T4 energy" type of protection Explosion protection to FM for USA FM approval FM Degree of protection IS/Cl I, II, III/Div 1/ GP ABCDEFG T6, T5, T4 IS/Cl I/ZN 0/AEx ia IIC T6, T5, T4 NI/Cl I, II, III/Div 2, GP ABCDFG T6, T5, T4 NI/Cl I/ZN 2/IIC T6, T5, T4 Explosion protection to FM for Canada ( c FM US ) FM approval FM C Degree of protection IS/Cl I/ZN 0/Ex ia IIC T6, T5, T4 NI/Cl I/ZN 2/Ex nal IIC T6, T5, T4 Factory setting: Pt100 (IEC 751) with three-wire circuit Measuring range: C ( F) Fault current: 22.8 ma Sensor offset: 0 C (0 F) Damping 0.0 s Digital measuring errors Resistance thermometer Input Measuring range Min. measured Digital accu- span racy C ( F) C ( F) C ( F) to IEC Pt (18) 0.2 (0.6) ( ) Pt (18) 0.15 (0.27) ( ) Pt Pt (18) 0.1 (0.18) ( ) Pt (18) 0.15 (0.27) ( ) Pt (18) 0.15 (0.27) ( ) to JIS C Pt (18) 0.2 (0.6) ( ) Pt (18) 0.15 (0.27) ( ) Pt Pt (18) 0.1 (0.18) ( ) Pt (18) 0.15 (0.27) ( ) Pt (18) 0.15 (0.27) ( ) Ni 25 to Ni (18) 0.1 (0.18) ( ) Siemens FI US Edition /15
16 Transmittters for mounting in sensor head SITRANS TH00 two-wire system, universal, HART Resistance-based sensors Input Measuring Min. measured Digital accuracy range span Ω Ω Ω Resistance Resistance Thermocouple elements Input 1) The digital accuracy in the range 0 to 00 C (2 to 572 F) is C (5.4 F). 2) The digital accuracy in the range 1750 to 200 C (182 to 4172 F) is 2 C (.6 F). mv sensor Input Measuring range Min. measured span Digital accuracy C ( F) C ( F) C ( F) Type B (180) 2 1) (.60) 1) ( ) Type C (W5) (180) 2 (.60) ( ) Type D (W) (180) 1 2) (1.80) 2) ( ) Type E (90) 1 (1.80) ( ) Type J (90) 1 (1.80) ( ) Type K (90) 1 (1.80) ( ) Type L (90) 1 (1.80) ( ) Type N (90) 1 (1.80) ( ) Type R (180) 2 (.60) ( ) Type S (180) 2 (.60) ( ) Type T (72) 1 (1.80) ( ) Type U ( ) 50 (90) 2 (.60) Measuring range Min. measured span mv mv μv mv sensor mv sensor Digital accuracy The digital accuracy is the accuracy after the analog/digital conversion including linearization and calculation of the measured value. An additional error is generated in the output current 4 to 20 ma as a result of the digital/analog conversion of 0.1 % of the set span (digital-analog error). The total error under reference conditions at the analog output is the sum from the digital error and the digital-analog error (poss. with the addition of cold junction errors in the case of thermocouple measurements). Siemens AG 2010 Selection and Ordering Data Order No. Temperature transmitter SITRANS TH00 for installation in the connection head type B (DIN 4729) 2-wire connection ma, communication-capable acc. to HART, with electrical isolation Without explosion protection } 7NG212-0NN00 C) With explosion protection - acc. to ATEX } 7NG212-0AN00 C) - acc. to FM (cfm US ) } 7NG212-0BN00 C) Further designs Order code Please add "-Z" to Order No. and specify Order code(s) Customer-specific setting of operating Y01 1) data (specify operating data in plain text) with test protocol (5 measuring C11 points) SIL 2 (functional safety) C20 Accessories Order No. CD for measuring instruments } A5E for temperature with documentation in German, English, French, Spanish, Italian, Portuguese and SIPROM T parameterization software HART modem With RS 22 connection } 7MF4997-1DA D) With USB connection } 7MF4997-1DB D) SIMATIC PDM operating See Section 9 software DIN rail adapters for head } 7NG092-8KA transmitters (Quantity delivered: 5 units) 4-wire connection cable 7NG092-8KC 150 mm, for sensor connections when using head transmitters in the high hinged cover (set with 5 units) } Available ex stock. 1) Y01: Please specify all data that does not correspond to factory settings (see below). C) Subject to export regulations AL: N, ECCN: EAR99. D) Subject to export regulations AL: N, ECCN: EAR99H. Power supply units see "SITRANS I supply units and isolation amplifiers". Factory setting: Pt100 (IEC 751) with three-wire circuit Measuring range: C ( F) Fault current: 22.8 ma Sensor offset: 0 C (0 F) Damping 0.0 s /16 Siemens FI US Edition
17 Dimensional drawings Siemens AG 2010 Transmittters for mounting in sensor head SITRANS TH00 two-wire system, universal, HART Mounting on DIN rail Ø 44 (1.7) (1.0) (1) (1) (2) () (2) (4) SITRANS TH00, mounting of transmitter on DIN rail 14 (0.55) 50,5 (1.99) (1.0) 26, (1.04) 59,6 (2.5) M4 x 0 1(+) and 2(-) Auxiliary power supply U aux, output current I Out, 4, 5 and 6 Pt100 sensor (for connections, see Sensor connection assignment) Test (+), Test (-) Measurement of the output current with a multimeter (1) Test terminal (2) Mounting screw M4x0 () LED for operation indication (4) Internal diameter of center hole 6. (0.25) DIN rail adapter, dimensions in mm (inch) SITRANS TH00, dimensions and pin assignment, dimensions in mm (inch) Siemens FI US Edition /17
18 Transmittters for mounting in sensor head SITRANS TH00 two-wire system, universal, HART Schematics Siemens AG 2010 Resistance thermometer Resistance Thermocouple Two-wire system 1) Two-wire system 1) Cold junction compensation Internal/fixed value Three-wire system Three-wire system Cold junction compensation with external Pt100 in two-wire system 1) Four-wire system Four-wire system Cold junction compensation with external Pt100 in three-wire system Generation of average value / difference 1) 1) Programmable line resistance for the purpose of correction. Generation of average value / difference 1) Generation of average value / difference with internal cold junction compensation Voltage measurement Current measurement Connection of auxiliary power supply (U aux ) U aux + - SITRANS TH200/TH00, sensor connection assignment /18 Siemens FI US Edition
19 Transmittters for mounting in sensor head SITRANS TH400 fieldbus transmitter Overview Application Linearized temperature measurement with resistance thermometers or thermocouple elements Differential, mean-value or redundant temperature measurement with resistance thermometers or thermocouple elements Linear resistance and bipolar millivolt measurements Differential, mean-value or redundant resistance and bipolar millivolt measurements SITRANS TH400 fieldbus transmitters Versions: for FOUNDATION Fieldbus and for PROFIBUS PA The SITRANS TH400 temperature transmitter is a small field bus transmitter for mounting in the connection head of form B. Extensive functionality enables the temperature transmitter to be precisely adapted to the plant s requirements. Operation is very simple in spite of the numerous setting options. Thanks to its universal concept it can be used in all industries and is easy to integrate in Totally Integrated Automation applications. Transmitters of the "intrinsically-safe" type of protection can be installed within potentially explosive atmospheres. The devices comply with the Directive 94/9/EC (ATEX), as well as FM and CSA regulations. Installing SITRANS TH400 in temperature sensors turns them into complete, bus-capable measuring points; compact - and in a single device. Function Features common Mounting in connection head, type B, to DIN 4729, or larger Polarity-neutral bus connection 24-bit analog-digital converter for high resolution Electrically isolated Intrinsically-safe version for use in potentially explosive areas Special characteristic Sensor redundance Transmitter with PROFIBUS PA communication Function blocks: 2 x analog Transmitter with FOUNDATION Fieldbus communication Function blocks: 2 x analog and 1 x PID Functionality: Basic or LAS Mode of operation The following function plan explains the mode of operation of the transmitter. The only difference between the two versions of the SITRANS TH400 (7NG and 7NG ) is the type of fieldbus protocol used (PROFIBUS PA or FOUNDATION fieldbus). Optional inputs: - Resistance thermometer - Thermocouple - mv sensor - Resistance-based sensors Transformer Input 1 Input 2 Differential Mean value Redundancy Terminal temperature Engineering units Diagnostic functions Table linearization Polynomial linearization Process calibration Input 1 Input A/D converter Electrically isolated CPU Communication Ex power circuit 1 2 Bus connection Internal Pt100 EEPROM Complex configuration Correction coefficient Factory settings - PROFIBUS protocol (7NG214) or - Foundation Fieldbus protocol (7NG215) SITRANS TH400, function diagram Siemens FI US Edition /19
20 Transmittters for mounting in sensor head SITRANS TH400 fieldbus transmitter System communication Bus terminator Bus terminator SITRANS TH400 PA SITRANS TH400 FF Output: SITRANS TH400, communication interface Technical specifications Input Analog-to-digital conversion Measurement rate < 50 ms Resolution 24 Bit Resistance thermometer Pt25... Pt1000 to IEC 60751/JIS C 1604 Measuring range C ( F) Ni25... Ni1000 to DIN 4760 Measuring range C ( F) Cu10... Cu1000, α = 0,00427 Measuring range C ( F) Line resistance per sensor cable Max. 50 Ω Sensor current Nominal 0.2 ma Sensor fault detection Sensor break detection Yes Sensor short-circuit detection Yes, < 15 Ω Resistance-based sensors Measuring range 0 Ω kω Line resistance per sensor cable Max. 50 Ω Sensor current Nominal 0.2 ma Sensor fault detection Sensor break detection Yes Sensor short-circuit detection Yes, < 15 Ω 2 s Bus connection 2 s 1 1 Bus connection PROFIBUS PA Segment coupler FOUNDATION Fieldbus Segment coupler Thermocouple to IEC 584 Type B Type E Type J Type K Type N Type R Type S Type T to DIN 4710 Type L Type U to ASTM E Type W Type W5 External cold junction compensation Sensor fault detection Sensor break detection Sensor short-circuit detection Sensor current in the event of open-circuit monitoring mv sensor - voltage input Measuring range Input resistance Output Filter time (programmable) Update time Measuring accuracy Accuracy is defined as the higher value of general values and basic values. General values Type of input All Measuring range C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) Yes Yes, < mv 4 μa mv 10 MΩ s < 400 ms Absolute accuracy ±0,05 % of measured value Temperature coefficient ±0,002 % of measured value/ C Basic values Type of input Basic accuracy Temperature coefficient Pt100 and Pt1000 ±0.1 C ±0.002 C/ C Ni100 ±0.15 C ±0.002 C/ C Cu10 ±1. C ±0.02 C/ C Resistance-based sensors ±0.05 Ω ±0.002 Ω/ C Voltage source ±10 μv ±0.2 μv/ C Thermal element, type: ±0.5 C ±0.01 C/ C E, J, K, L, N, T, U Thermal element, type: ±1 C ±0.025 C/ C B, R, S, W, W5 Cold junction compensation ±0.5 C Reference conditions Warming-up time 0 s Signal-to-noise ratio Min. 60 db Calibration condition C ( F) /20 Siemens FI US Edition
21 Transmittters for mounting in sensor head SITRANS TH400 fieldbus transmitter Rated conditions Ambient temperature Permissible ambient temperature C ( F) Permissible storage temperature C ( F) Relative humidity 98 %, with condensation Electrically isolated without Ex Input against output1 kv eff with Ex Input against output 500 V eff Mechanical testing Vibrations (DIN class B) to IEC and IEC g/ Hz Electromagnetic compatibility EMC noise voltage influence < ±0,1 % of span Extended EMC noise immunity: < ±1 % of span NAMUR NE 21, criterion A, Burst EMC 2004/108/EC Emission and EN 6126 Noise Immunity to Design Material Molded plastic Weight 55 g (0.12 lb) Dimensions See "Dimensional drawings" Cross-section of cables Max. 2.5 mm² (AWG 1) Degree of protection Transmitter enclosure IP40 Terminal IP00 Auxiliary power supply Power supply Standard, Ex na, Ex nl and NI DC V ATEX, FM, UL and CSA DC V In FISCO/FNICO installation DC V Power consumption < 11 ma Max. increase in power consumption in the event of a < 7 ma fault Certificate and approvals Explosion protection ATEX EC type test certificate KEMA 06 ATEX 0264 X "Intrinsic safety" type of protection II 1 GD EEx ia IIC T4... T6 T65 C... T105 C II 2(1) GD EEx ib [ia] IIC T4... T6 T65 C... T105 C EC type test certificate KEMA 06 ATEX 026 X "Operating equipment that is nonignitable type of protection Explosion protection FM for USA FM approval FM Degree of protection Explosion protection CSA for Canada II G EEx na[nl] IIC T4... T6 II G EEx nl IIC T4... T6 IS/Cl I/Div 1/Groups ABCD T4, T5, T6, FISCO IS/Cl I/ZN 0/AEx ia, IIC T4, T5, T6, FISCO NI/Cl I/Div 2/Groups ABCD T4, T5, T6, FNICO CSA approval CSA Degree of protection IS/Cl I/Groups ABCD T4, T5, T6 Ex ia IIC T4/T5/T6 Ex ib [ia] IIC T4/T5/T6 Cl I/Div 2/Groups ABCD T4, T5, T6 Ex na IIC T4/T5/T6 CI I/ZN 2/ AEx na II T4, T5, T6 Communication Parameterization interface PROFIBUS PA connection - Protocol Profile.0 - Address (for delivery) 126 FOUNDATION Fieldbus connection - Protocol FF Protocoll - Functionality Basic or LAS - Version ITK Function blocks 2 x Analog and 1 x PID Factory setting for SITRANS TH400 PA and SITRANS TH400 FF Sensor Pt100 (IEC) Type of connection Three-wire system Unit C Failure mode Last valid value Filter time 0 s only for SITRANS TH400 PA PA address 126 PROFIBUS Ident No. Manufacturer-specific only for SITRANS TH400 FF Node address 22 Siemens FI US Edition /21
22 Transmittters for mounting in sensor head SITRANS TH400 fieldbus transmitter Selection and Ordering data Temperature transmitter SITRANS TH400 for installation in the sensor head, with electrical isolation, order instruction manual separately. Bus-capable to PROFIBUS PA - without explosion protection or EEx n or NI - with explosion protection intrinsic safety to ATEX/FM/CSA Bus-capable to FOUNDATION Fieldbus - without explosion protection or EEx n or NI - with explosion protection intrinsic safety to ATEX/FM/CSA Further designs Order No. } 7NG214-0NN00 C) } 7NG214-0AN00 C) } 7NG215-0NN00 C) } 7NG215-0AN00 C) Order code Please add -Z to Order No. and specifiy Order code (s) and plain text. Customer-specific setting of operating Y01 1) data (specify in plain text) With test protocol (5 measuring points) C11 2) Accessories Order No. CD for measuring instruments for } A5E temperature with documentation in German, English, French, Spanish, Italian, Portuguese and SIPROM T parameterization software SIMATIC PDM operating software see chapter 9 DIN rail adapters for head transmitters 7NG092-8KA (Quantity delivered: 5 units) 4-wire connection cable 7NG092-8KC 150 mm, for sensor connections when using head transmitters in the high hinged cover (set with 5 units) For additional PA components see catalog IK PI } Available ex stock. 1) Y01: Please specify all data that does not correspond to factory settings (see below). 2) Can only be ordered together with Y01 (it is essential to specify the measuring range). C) Subject to export regulations AL: N, ECCN: EAR99. Dimensional drawings s W (1.) Ø 44 (1.7) Terminals 1, 2: Fieldbus connection Terminals... 6: Sensor connection SITRANS TH400 dimensions in mm (inches) and connections Mounting on DIN rail Ø 6, (0.25) M4 x 0 SITRANS TH400, mounting of transmitter on DIN rail 14 (0.55) 50,5 (1.99) (1.0) 26, (1.04) Factory setting: for SITRANS TH400 PA: - Pt100 (IEC 751) with three-wire circuit - Unit: C - Failure mode: Last valid value - Filter time: 0 s - PA address: PROFIBUS Ident No.: Manufacturer-specific for SITRANS TH400 FF: - Pt100 (IEC 751) with three-wire circuit - Unit: C - Failure mode: Last valid value - Filter time: 0 s - Node address: 22 DIN rail adapter, dimensions in mm (inch) 59,6 (2.5) /22 Siemens FI US Edition
23 Transmittters for mounting in sensor head SITRANS TH400 fieldbus transmitter Schematics Resistance thermometer Thermocouple Resistance Two-wire system 1) + - Internal cold junction compensation Two-wire system 1) + - Three-wire system Cold junction compensation with external Pt100 in two-wire system 1) Three-wire system + - Four-wire system Cold junction compensation with external Pt100 in three-wire system Four-wire system Mean-value/differential or redundancy generation 2 x two-wire system 1) Mean value, differential or redundancy generation with internal cold junction compensation Mean value, differential or redundancy generation 1 resistor in two-wire system 1) 1 resistor in three-wire system Voltage measurement Mean-value/differential or redundancy generation 1 sensor in two-wire system 1) 1 sensor in three-wire system Mean value, differential or redundancy generation and cold junction compensation with internal Pt100 in two-wire system 1) + - One voltage source 1) Programmable line resistance for the purpose of correction Measurement of mean value, differential and redundancy with 2 voltage sources SITRANS TH400, sensor connection assignment Siemens FI US Edition /2
24 Transmitters for rail mounting SITRANS TR200 two-wire system, universal Overview Ultra flexible - with the universal SITRANS TR200 transmitter Two-wire devices for 4 to 20 ma Enclosure for rail mounting Universal input for virtually any type of temperature sensor Configurable over PC Benefits Compact design Electrically isolated Test sockets for multimeters Diagnostics LED (green/red) Sensor monitoring open circuits and short-circuits Self-monitoring Configuration status stored in EEPROM Expanded diagnostic functions, such as slave pointer, operating hours counter, etc. Special characteristic Electromagnetic compatibility to EN 6126 and NE21 SIL 2 (with order code C20) Application SITRANS TR200 transmitters can be used in all industrial sectors. Their compact design enables simple mounting on standard DIN rails on-site in protective boxes or in control cabinets. The following sensors/signal sources can be connected over their universal input module: Resistance thermometers (two, three or four-wire system) Thermocouple elements Resistance-based sensors and DC voltage sources The output signal is a direct current from 4 to 20 ma in accordance with the sensor characteristic. Transmitters of the "intrinsically-safe" type of protection can be installed within potentially explosive atmospheres. The devices comply with the Directive 94/9/EC (ATEX). Function The SITRANS TR200 is configured over a PC. A USB or RS 22 modem is linked to the output terminals for this purpose. The configuration data can now be edited using the SIPROM T software tool. The configuration data are then permanently stored in the non-volatile memory (EEPROM). Once the sensors and power supply have been correctly connected, the transmitter outputs a temperature-linear output signal and the diagnostics LED displays a green light. In the case of a sensor short-circuit, the LED flashes red, an internal device fault is indicated by a steady red light. The test socket can be used to connect an ammeter at any time for monitoring purposes and plausibility checks. The output current can be read without any interruption, or even without opening the current loop. SITRANS TR200/TR00 Sensor TC/RTD Test A D μc1 4 μc2 5 D 6 A ma U aux, I out 1 Sensor such as resistance thermometer, thermocouple, resistance-based, sensor, mv sensor 2 Analog-digital converter Microcontroller, secondary circuit 4 Electrical isolation 5 Microcontroller, primary circuit 6 Digital-analog converter 7 LED Auxiliary power supply Output current Test Test terminals for temporary connection of an amperemeter U aux I out SITRANS TR200 function diagram /24 Siemens FI US Edition
25 Transmitters for rail mounting SITRANS TR200 two-wire system, universal Technical specifications Input Resistance thermometer Measured variable Sensor type to IEC to JIS C 1604; a= K -1 to IEC Temperature Pt25... Pt1000 Pt25... Pt1000 Ni25... Ni1000 Special type Over special characteristic (max. 0 points) Sensor factor (adaptation of the basic type, e.g. Pt100 to version Pt25... Pt1000) Units C or F Connection Standard connection 1 resistance thermometer (RTD) in 2-wire, -wire or 4-wire system Generation of average value 2 identical resistance thermometers in 2-wire system for generation of average temperature Generation of difference 2 identical resistance thermometers (RTD) in 2-wire system (RTD 1 RTD 2 or RTD 2 RTD 1) Interface Two-wire system Parameterizable line resistance 100 Ω (loop resistance) Three-wire system No balancing required Four-wire system No balancing required Sensor current 0.45 ma Response time T ms for 1 sensor with opencircuit monitoring Open-circuit monitoring Always active (cannot be disabled) Short-circuit monitoring Can be switched off (value is adjustable) Measuring range Parameterizable (see table "Digital measuring errors") Min. measured span 10 C (18 F) Characteristic curve Temperature-linear or special characteristic Resistance-based sensors Measured variable Actual resistance Sensor type Resistance-based, potentiometers Units Ω Connection Normal connection 1 resistance-based sensor (R) in 2-wire, -wire or 4-wire system Generation of average value 2 resistance-based sensors in 2-wire system for generation of average value Generation of difference 2 resistance thermometers in 2-wire system (R1 R2 or R2 R1) Interface Two-wire system Parameterizable line resistance 100 Ω (loop resistance) Three-wire system No balancing required Four-wire system No balancing required Sensor current 0.45 ma Response time T ms for 1 sensor with opencircuit monitoring Open-circuit monitoring Always active (cannot be disabled) Short-circuit monitoring Can be switched off (value is adjustable) Measuring range Parameterizable, max Ω (see Table "Digital measuring errors") Min. measured span Ω (see Table "Digital measuring errors") Characteristic curve Resistance-linear or special characteristic Thermocouple elements Measured variable Temperature Sensor type (thermocouples) Type B Pt0Rh-Pt6Rh to DIN IEC 584 Type C W5 %-Re to ASTM 988 Type D W %-Re to ASTM 988 Type E NiCr-CuNi to DIN IEC 584 Type J Fe-CuNi to DIN IEC 584 Type K NiCr-Ni to DIN IEC 584 Type L Fe-CuNi to DIN 4710 Type N NiCrSi-NiSi to DIN IEC 584 Type R Pt1Rh-Pt to DIN IEC 584 Type S Pt10Rh-Pt to DIN IEC 584 Type T Cu-CuNi to DIN IEC 584 Type U Cu-CuNi to DIN 4710 Units C or F Connection Standard connection 1 thermocouple element (TC) Generation of average value 2 identical thermocouple elements (TC) Generation of difference 2 identical thermocouple elements (TC) TC1 TC2 or TC2 TC1 Response time T ms for 1 sensor with opencircuit monitoring Open-circuit monitoring Can be switched off Cold junction compensation Internal With integrated Pt100 resistance thermometer External With external Pt100 IEC (2-wire or -wire connection) External fixed Cold junction temperature can be set as fixed value Measuring range Parameterizable (see table "Digital measuring errors") Min. measured span Min C ( F) (see table "Digital measuring errors") Characteristic curve Temperature-linear or special characteristic mv sensor Measured variable DC voltage Sensor type DC voltage source (DC voltage source possible over an externally connected resistor) Units mv Response time T ms for 1 sensor with opencircuit monitoring Open-circuit monitoring Can be switched off Siemens FI US Edition /25
26 Transmitters for rail mounting SITRANS TR200 two-wire system, universal Measuring range Min. measured span Overload capability of the input Input resistance Characteristic curve Output Output signal Auxiliary power supply Max. load Overrange Error signal (e.g. in the event of sensor breakage) Parameterizable max mv 2 mv or 20 mv V DC 1 MΩ Voltage-linear or special characteristic ma, 2-wire V DC (to 0 V with Ex) (U aux 11 V)/0.02 A ma, infinitely adjustable (default range:.84 ma ma) ma, infinitely adjustable (default value: 22.8 ma) Sample cycle 0.25 s Damping Software filter 1st order s (parameterizable) Protection Against reversed polarity Electrically isolated Input against output (1 kv eff ) Measuring accuracy Digital measuring errors See Table "Digital measuring errors" Reference conditions Auxiliary power supply 24 V ± 1% Load 500 Ω Ambient temperature 2 C Warming-up time > 5 min Error in the analog output (digital/analog converter) < % of span Error due to internal cold junction < 0.55 C (0.9 F) Temperature effect < 0.1 % of max. span/10 C (18 F) Power supply effect < % of span/v Effect of load impedance < % of span/100 Ω Long-term drift in the first month < 0.02 % of max. span after one year < 0.2 % of max. span after 5 years < 0. % of max. span Rated conditions Ambient conditions Ambient temperature range C ( F) Storage temperature range C ( F) Relative humidity < 98 %, with condensation Electromagnetic compatibility According to EN 6126 and NAMUR NE21 Design Material Plastic, electronic module potted Weight 122 g Dimensions See "Dimensional drawings" Cross-section of cables Max. 2.5 mm² (AWG 1) Degree of protection to IEC Enclosure IP20 Certificates and approvals Explosion protection ATEX EC type test certificate PTB 07 ATEX 202X "Intrinsic safety" type of protection II 2(1) G Ex ia/ib IIC T6/T4 II (1) G Ex ia/ic IIC T6/T4 II 2(1) D Ex iad/ibd 20/21 T115 C Type of protection, "equipment has II G Ex nl IIC T6/T4 limited energy" Type of protection, "equipment is II G Ex na IIC T6/T4 non-arcing" Software requirements for SIPROM T PC operating system Windows ME, 2000 and XP; also Windows 95, 98 and 98 SE, but only in connection with RS 22 modem. Factory setting: Pt100 (IEC 751) with three-wire circuit Measuring range: C ( F) Fault current: 22.8 ma Sensor offset: 0 C (0 F) Damping 0.0 s Digital measuring errors Resistance thermometer Input Measuring range Min. measured Digital span accuracy C ( F) C ( F) C ( F) to IEC Pt (18) 0.2 (0.6) ( ) Pt (18) 0.15 (0.27) ( ) Pt Pt (18) 0.1 (0.18) ( ) Pt (18) 0.15 (0.27) ( ) Pt (18) 0.15 (0.27) ( ) to JIS C Pt (18) 0.2 (0.6) ( ) Pt (18) 0.15 (0.27) ( ) Pt Pt (18) 0.1 (0.18) ( ) Pt (18) 0.15 (0.27) ( ) Pt (18) 0.15 (0.27) ( ) Ni 25 to Ni (18) 0.1 (0.18) ( ) /26 Siemens FI US Edition
27 Resistance-based sensors Input Measuring Min. measured Digital range span accuracy Ω Ω Ω Resistance Resistance Thermocouple elements Input 1) The digital accuracy in the range 0 to 00 C (2 to 572 F) is C (5.4 F). 2) The digital accuracy in the range 1750 to 200 C (182 to 4172 F) is 2 C (.6 F). mv sensor Input Measuring range The digital accuracy is the accuracy after the analog/digital conversion including linearization and calculation of the measured value. An additional error is generated in the output current 4 to 20 ma as a result of the digital/analog conversion of 0.1 % of the set span (digital-analog error). The total error under reference conditions at the analog output is the sum from the digital error and the digital-analog error (poss. with the addition of cold junction errors in the case of thermocouple measurements). Transmitters for rail mounting SITRANS TR200 two-wire system, universal Min. measured span Digital accuracy C ( F) C ( F) C ( F) Type B (180) 2 1) (.60) 1) ( ) Type C (W5) (180) 2 (.60) ( ) Type D (W) (180) 1 2) (1.80) 2) ( ) Type E (90) 1 (1.80) ( ) Type J (90) 1 (1.80) ( ) Type K (90) 1 (1.80) ( ) Type L (90) 1 (1.80) ( ) Type N (90) 1 (1.80) ( ) Type R (180) 2 (.60) ( ) Type S (180) 2 (.60) ( ) Type T (72) 1 (1.80) ( ) Type U ( ) 50 (90) 2 (.60) Measuring range Min. measured span mv mv μv mv sensor mv sensor Digital accuracy Siemens AG 2010 Selection and Ordering Data Order No. Temperature transmitter SITRANS TR200 for mounting on a standard DIN rail, two-wire system, 4 to 20 ma, programmable, with electrical isolation, with documentation on CD Without explosion protection } 7NG02-0JN00 D) With explosion protection to } 7NG02-1JN00 ATEX D) Further designs Order code Please add "-Z" to Order No. and specify Order code(s) Customer-specific setting of operating data (specify operating data Y01 1) in plain text) with test protocol (5 measuring C11 points) SIL 2 (functional safety) C20 Accessories Order No. Modem for SITRANS TH100, TH200 and TR200 incl. SIPROM T parameterization software With USB connection } 7NG092-8KU C) With RS 22 connection } 7NG092-8KM C) CD for measuring instruments } A5E for temperature with documentation in German, English, French, Spanish, Italian, Portuguese and SIPROM T parameterization software } Available ex stock. 1) Y01: Please specify all data that does not correspond to factory settings (see below). C) Subject to export regulations AL: N, ECCN: EAR99. D) Subject to export regulations AL: N, ECCN: EAR99H. Power supply units see "SITRANS I supply units and isolation amplifiers". Factory setting: Pt100 (IEC 751) with three-wire circuit Measuring range: C ( F) Fault current: 22.8 ma Sensor offset: 0 C (0 F) Damping 0.0 s Siemens FI US Edition /27
28 Transmitters for rail mounting SITRANS TR200 two-wire system, universal Dimensional drawings Schematics TEST 4..20mA SIEMENS 22,5 (0.89) SITRANS TR (.9) 1 2 TEST mA SIEMENS SITRANS TR200 Made in Croatia + + S1 S mA loop & test S1 2x RTD or R 2W sensor 2x TC sensor with int./fixed CJC RTD or R 2W sensor RTD or R W sensor RTD or R 4W sensor S2 5 6 s Connection Plan 4 +UB TC sens. with int./fixed CJC U sensor + TC sensor with external 2W RTD CJC + TC sensor with external W RTD CJC 114 (4.49) TEST + - A Asssignments 1 (+) and 2 (-) Test terminals (Test) for measurement of the output current with a multimeter (+) and 4 (-) Power supply U aux, Output current I out 5, 6, 7 and 8 Sensor assignment, see schematics SITRANS TR200, dimensions in mm (inch) SITRANS pin assignment, TR200 /28 Siemens FI US Edition
29 Transmitters for rail mounting SITRANS TR200 two-wire system, universal Resistance thermometer Resistance Thermocouple RTD Two-wire system 1) Two-wire system R TC - + 1) Cold junction compensation Internal/fixed value TC - + RTD Three-wire system R Three-wire system RTD Cold junction compensation with external Pt100 in two-wire system 1) RTD Four-wire system R Four-wire system TC - + RTD Cold junction compensation with external Pt100 in three-wire system RTD2 RTD1 Generation of average value/difference 1) 1) Programmable line resistance for the purpose of correction. R2 R1 Generation of average value/difference 1) TC1 TC Generation of average value / difference with internal cold junction compensation Voltage measurement Current measurement Test terminals Power supply/ ma (U aux ) + A - U aux U R - + I SITRANS TR200, sensor connection assignment Siemens FI US Edition /29
30 Transmitters for rail mounting SITRANS TR00 two-wire system, universal, HART Overview Application SITRANS TR00 transmitters can be used in all industrial sectors. Their compact design enables simple mounting on standard DIN rails on-site in protective boxes or in control cabinets. The following sensors/signal sources can be connected over their universal input module: Resistance thermometers (two, three or four-wire system) Thermocouple elements Resistance-based sensors and DC voltage sources The output signal is a direct current from 4 to 20 ma in accordance with the sensor characteristic, superimposed by the digital HART signal. Transmitters of the "intrinsically-safe" type of protection can be installed within potentially explosive atmospheres. The devices comply with the Directive 94/9/EC (ATEX). "HART" to beat - the universal SITRANS TR00 transmitter Two-wire devices for 4 to 20 ma, HART Device for rail mounting Universal input for virtually any type of temperature sensor Configurable over HART Benefits Compact design Electrically isolated Test sockets for multimeters Diagnostics LED (green/red) Sensor monitoring open circuits and short-circuits Self-monitoring Configuration status stored in EEPROM Expanded diagnostic functions, such as slave pointer, operating hours counter etc. Special characteristic Electromagnetic compatibility to EN 6126 and NE21 SIL 2 (with order code C20) Function The SITRANS TR00 is configured over HART. This can be done using a handheld communicator or even more conveniently with a HART modem and the SIMATIC PDM parameterization software. The configuration data are then permanently stored in the non-volatile memory (EEPROM). Once the sensors and power supply have been correctly connected, the transmitter outputs a temperature-linear output signal and the diagnostics LED displays a green light. In the case of a sensor short-circuit, the LED flashes red, an internal device fault is indicated by a steady red light. The test socket can be used to connect an ammeter at any time for monitoring purposes and plausibility checks. The output current can be read without any interruption, or even without opening the current loop. SITRANS TR200/TR00 Sensor TC/RTD Test A D μc1 4 μc2 5 D A ma U aux, I out 1 Sensor such as resistance thermometer, thermocouple, resistance-based, sensor, mv sensor 2 Analog-digital converter Microcontroller, secondary circuit 4 Electrical isolation 5 Microcontroller, primary circuit 6 Digital-analog converter 7 LED Auxiliary power supply Output current Test Test terminals for temporary connection of an amperemeter U aux I out SITRANS TR00 function diagram /0 Siemens FI US Edition
31 Transmitters for rail mounting SITRANS TR00 two-wire system, universal, HART Technical specifications Input Resistance thermometer Measured variable Sensor type to IEC to JIS C 1604; a= K-1 to IEC Temperature Pt25... Pt1000 Pt25... Pt1000 Ni25... Ni1000 Special type over special characteristic (max. 0 points) Sensor factor (adaptation of the basic type, e.g. Pt100 to version Pt25... Pt1000) Units C or F Connection Standard connection 1 resistance thermometer (RTD) in 2-wire, -wire or 4-wire system Generation of average value 2 identical resistance thermometers in 2-wire system for generation of average temperature Generation of difference 2 identical resistance thermometers (RTD) in 2-wire system (RTD 1 RTD 2 or RTD 2 RTD 1) Interface Two-wire system Parameterizable line resistance 100 Ω (loop resistance) Three-wire system No balancing required Four-wire system No balancing required Sensor current 0.45 ma Response time T ms for 1 sensor with opencircuit monitoring Open-circuit monitoring can be switched off Short-circuit monitoring can be switched off (value is adjustable) Range Parameterizable (see table "Digital measuring errors") Min. measured span 10 C (18 F) Characteristic Temperature-linear or special characteristic Resistance-based sensors Measured variable Actual resistance Sensor type Resistance-based, potentiometers Units Ω Connection Normal connection 1 resistance-based sensor (R) in 2-wire, -wire or 4-wire system Generation of average value 2 resistance-based sensors in 2-wire system for generation of average value Generation of difference 2 resistance thermometers in 2-wire system (R1 R2 or R2 R1) Interface Two-wire system Parameterizable line resistance 100 Ω (loop resistance) Three-wire system No balancing required Four-wire system No balancing required Sensor current 0.45 ma Response time T ms for 1 sensor with opencircuit monitoring Open-circuit monitoring Can be switched off Short-circuit monitoring Can be switched off (value is adjustable) Range Parameterizable, max Ω (see Table "Digital measuring errors") Min. measured span 5 Ω Ω (see Table "Digital measuring errors") Characteristic Resistance-linear or special characteristic Thermocouple elements Measured variable Temperature Sensor type (thermocouples) Type B Pt0Rh-Pt6Rh to DIN IEC 584 Type C W5 %-Re to ASTM 988 Type D W %-Re to ASTM 988 Type E NiCr-CuNi to DIN IEC 584 Type J Fe-CuNi to DIN IEC 584 Type K NiCr-Ni to DIN IEC 584 Type L Fe-CuNi to DIN 4710 Type N NiCrSi-NiSi to DIN IEC 584 Type R Pt1Rh-Pt to DIN IEC 584 Type S Pt10Rh-Pt to DIN IEC 584 Type T Cu-CuNi to DIN IEC 584 Type U Cu-CuNi to DIN 4710 Units C or F Connection Standard connection 1 thermocouple (TC) Generation of average value 2 thermocouples (TC) Generation of difference 2 thermocouples (TC) TC1 TC2 or TC2 TC1 Response time 250 ms for 1 sensor with open-circuit monitoring Open-circuit monitoring Can be switched off Cold junction compensation Internal With integrated Pt100 resistance thermometer External With external Pt100 IEC (2-wire or -wire connection) External fixed Cold junction temperature can be set as fixed value Range Parameterizable (see table "Digital measuring errors") Min. measured span Min C ( F) (see table "Digital measuring errors") Characteristic Temperature-linear or special characteristic mv Sensor Measured variable DC voltage Sensor type DC voltage source (DC voltage source possible over an externally connected resistor) Units mv Response time T ms for 1 sensor with opencircuit monitoring Open-circuit monitoring Can be switched off Short-circuit monitoring Can be switched off (value is adjustable) Siemens FI US Edition /1
32 Transmitters for rail mounting SITRANS TR00 two-wire system, universal, HART Range Min. measured span Overload capacity of the input Input resistance Characteristic Output Output signal Power supply Max. load Overrange Error signal (e.g. in the event of sensor breakage) mv mv 2 mv or 20 mv V DC 1 MΩ Voltage-linear or special characteristic ma, 2-wire Communication acc. to HART Rev V DC (to 0 V with EEx) (U aux 11 V)/0.02 A ma, continuously adjustable (default range: ma) ma, continuously adjustable (default value: 22.8 ma) Sample cycle 0.25 s nominal Damping Software filter 1st order s (parameterizable) Protection Against reversed polarity Electrically isolated Input against output (1 kv eff ) Measuring accuracy Digital measuring errors See Table "Digital measuring errors" Reference conditions Power supply 24 V ± 1% Load 500 Ω Storage temperature 2 C Warming-up time > 5 min Error in the analog ouput (digital/analog converter) < % of span Error due to internal cold junction < 0.5 C (0.9 F) Temperature effect < 0.1 % der max. span/10 C (18 F) Power supply effect < % of span/v Effect of load impedance < % of span/100 Ω Long-term drift in the first month < 0.02 % of max. span after one year < 0.2 % of max. span after 5 years < 0. % of max. span Rated conditions Ambient temperature Storage temperature C ( F) Functional temperature C ( F) Relative humidity < 98 %, with condensation Electromagnetic compatibility acc. to DIN EN 6126 and NE21 Design Material Molded plastic Approx. weight 50 g (0.11 lb) Dimensions See "Dimension drawings" Cross-section of cables Max. 2.5 mm² (AWG 1) Degree of protection to EN Enclosure IP40 Terminals IP00 Certificate and approvals Explosion protection ATEX EC type test certificate PTB 07 ATEX 202X "Intrinsic safety" type of protection II 2(1) G Ex ia/ib IIC T6/T4 II (1) G Ex ia/ic IIC T6/T4 II 2(1) D Ex iad/ibd 20/21 T115 C Type of protection, "equipment has II G Ex nl IIC T6/T4 limited energy" Type of protection, "equipment is II G Ex na IIC T6/T4 non-arcing" Software requirements for SIPROM T PC operating system: Windows ME, 2000 and XP; also Windows 95, 98 and 98 SE, but only in connection with RS 22 modem. Factory setting: Pt100 (IEC 751) with three-wire circuit Measuring range: C ( F) Fault current: 22.8 ma Sensor offset: 0 C (0 F) Damping 0.0 s Digital measuring errors Resistance thermometer input Range Min. measured span Digital accuracy C ( F) C ( F) C ( F) to IEC Pt (18) 0.2 (0.6) ( ) Pt (18) 0.15 (0.27) ( ) Pt Pt (18) 0.1 (0.18) ( ) Pt (18) 0.15 (0.27) ( ) Pt (18) 0.15 (0.27) ( ) to JIS C Pt (18) 0.2 (0.6) ( ) Pt (18) 0.15 (0.27) ( ) Pt Pt (18) 0.1 (0.18) ( ) Pt (18) 0.15 (0.27) ( ) Pt (18) 0.15 (0.27) ( ) Ni Ni ( ) 10 (18) 0.1 (0.18) /2 Siemens FI US Edition
33 Resistance-based sensors Input Range Min. measured Digital span accuracy Ω Ω Ω Resistance Resistance Thermocouple elements Input Measuring range 1) The digital accuracy in the range 0 to 00 C (2 to 572 F) is C (5.4 F). 2) The digital accuracy in the range 1750 to 200 C (182 to 4172 F) is 2 C (.6 F). mv Sensor input Range Min. measured Digital span accuracy mv mv μv mv Sensor mv Sensor The digital accuracy is the accuracy after the analog/digital conversion including linearization and calculation of the measured value. An additional error is generated in the output current 4 to 20 ma as a result of the digital/analog conversion of 0.1 % of the set span (digital-analog error). The total error under reference conditions at the analog output is the sum from the digital error and the digital-analog error (poss. with the addition of cold junction errors in the case of thermocouple measurements). Transmitters for rail mounting SITRANS TR00 two-wire system, universal, HART Min. measured span Digital accuracy C ( F) C ( F) C ( F) Type B (180) 2 1) (.60) 1) ( ) Type C (W5) (180) 2 (.60) ( ) Type D (W) (180) 1 2) (1.80) 2) ( ) Type E (90) 1 (1.80) ( ) Type J (90) 1 (1.80) ( ) Type K (90) 1 (1.80) ( ) Type L (90) 1 (1.80) ( ) Type N (90) 1 (1.80) ( ) Type R (180) 2 (.60) ( ) Type S (180) 2 (.60) ( ) Type T (72) 1 (1.80) ( ) Type U ( ) 50 (90) 2 (.60) Siemens AG 2010 Selection and Ordering Data Order No. Temperature transmitter SITRANS TR00 for mounting on a standard DIN rail, two-wire system, ma, HART, with electrical isolation, with documentation on CD Without explosion protection } 7NG0-0JN00 D) With explosion protection to } 7NG0-1JN00 ATEX D) Further designs Order code Please add "-Z" to Order No. and specify Order code(s) Customer-specific setting of operating data (specify operating data Y01 1) in plain text) with test protocol (5 measuring C11 points) SIL 2 (functional safety) C20 Accessories Order No. CD for measuring instruments } A5E for temperature with documentation in German, English, French, Spanish, Italian, Portuguese and SIPROM T parameterization software HART modem With RS 22 connection } 7MF4997-1DA D) With USB connection } 7MF4997-1DB D) SIMATIC PDM operating software See Section 9 } Available ex stock. 1) Y01: Please specify all data that does not correspond to factory settings (see below). D) Subject to export regulations AL: N, ECCN: EAR99H. Power supply units see "SITRANS I supply units and isolation amplifiers". Factory setting: Pt100 (IEC 751) with three-wire circuit Measuring range: C ( F) Fault current: 22.8 ma Sensor offset: 0 C (0 F) Damping 0.0 s Siemens FI US Edition /
34 Transmitters for rail mounting SITRANS TR00 two-wire system, universal, HART Dimensional drawings Schematics 22,5 (0.89) TEST 4..20mA SIEMENS SITRANS TR00 99 (.9) 1 2 TEST mA SIEMENS SITRANS TR00 Made in Croatia S1 2x RTD or R 2W sensor TC sens. with int./fixed CJC U sensor (4.49) 4..20mA loop & test + 2x TC sensor with int./fixed CJC RTD or R 2W sensor RTD or R W sensor RTD or R 4W sensor + S1 S S2 TC sensor with external 2W RTD CJC UB TEST + - A s Connection Plan TC sensor with external W RTD CJC Assignments 1 (+) and 2 (-) Test terminals (Test) for measurement of the output current with a multimeter (+) and 4 (-) Power supply U aux, Output current I out 5, 6, 7 and 8 Sensor assignment, see schematics SITRANS TR00, dimensions in mm (inch) SITRANS TR00, pin assignment /4 Siemens FI US Edition
35 Transmitters for rail mounting SITRANS TR00 two-wire system, universal, HART Resistance thermometer Resistance Thermocouple RTD Two-wire system 1) Two-wire system R TC - + 1) Cold junction compensation Internal/fixed value TC - + RTD Three-wire system R Three-wire system RTD Cold junction compensation with external Pt100 in two-wire system 1) RTD Four-wire system R Four-wire system TC - + RTD Cold junction compensation with external Pt100 in three-wire system RTD2 RTD1 Generation of average value/difference 1) 1) Programmable line resistance for the purpose of correction. R2 R1 Generation of average value/difference 1) TC1 TC Generation of average value / difference with internal cold junction compensation Voltage measurement Current measurement Test terminals Power supply/ ma (U aux ) + A - U aux U R - + I SITRANS TR00, sensor connection assignment Siemens FI US Edition /5
36 Transmitter for field mounting with temperature sensor SITRANS TF2 Digital display thermometer Overview The temperature transmitter SITRANS TF2 integrates three elements in one device: a Pt100 resistance thermometer in a stainless steel protective tube, a stainless steel housing with a high degree of protection, and a built-in transmitter with LCD and three keys for parameterization. It is used to indicate and monitor the temperature measured at the point of installation. The SITRANS TF2 is available in an axial and a radial version. Benefits Robust stainless steel housing with two connection versions High measuring accuracy Precise display with a resolution of 1 / 100 C in the highest measuring range Measuring ranges from -50 to +200 C ( F) parameterizable Customer-specific lengths and materials possible for the protective tube Stainless steel protective tube with high resistance to chemicals Signaling of limit violation in the LCD as well as with a red LED Application The SITRANS TF2 is used for indicating and monitoring a temperature variable at the point of installation. Applications are all process engineering branches, e.g.: Chemical industry Energy industry Long-distance heating Water supply Sewage works Food industry Steelworks and the cement industry Pharmaceutical industry Biotechnology Design The SITRANS TF2 has a stainless steel housing (diam. 80 mm) with protective glass. The stainless steel protective tube with screw socket contains the temperature sensor Pt100. By using stainless steel for the protective tube it displays high chemical resistance, which means that the temperature sensor is well protected against external effects. The protective tube is supplied as standard in lengths of 170 mm or 260 mm; a customer-specific version is also possible. Similarly, the protective tube can be supplied in the material of the customer s choice. At the rear of the housing is the electrical connection for the voltage supply using a current loop of 4 to 20 ma. The connection is made with plug connectors to EN A. At the front of the housing is the 5-digit display behind a glass cover. Underneath the display are the keys for parameterizing the SITRANS TF2. Above the display are a green and a red LED for indicating the operating status. The SITRANS TF2 is available in two versions (see "Dimensional drawings ): In the radial version (type A) the display is fitted in parallel with the protective tube. The display can be rotated by up to ±120 relative to the protective tube. In the axial version (type B) the display is at right angles to the protective tube. The display can be rotated by 60 relative to the protective tube. Function Mode of operation RTD I K EEPROM A/D D/A Green LED μc Red LED keys LCD C U K EMV + U A U ma I U H, I - A keys Configuring of parameters A/D Analog-to-digital converter D/A Digital-to-analog converter EEPROM Memory for all parameters EMC Output stage with protective components I A Current output I K Constant-current source LCD Display of measured values with dimension Green LED Display of normal mode Red LED Display of error messages or limit violation RTD Pt100 resistance thermometer U H Power supply μc Microcontroller for computing functions ond monitoring The outside lying temperature sensor Pt100 is supplied with current from the constant current course I k. A temperature-related voltage drop is thus created over the sensor. The voltage drop is converted on the analog/digital converter (A/D) into a digital signal. In the microcontroller (μc) the digital signal is linearized and evaluated in accordance with the data saved in the EEPROM. The processed data are shown in the display. In addition the values are converted on the digital/analog converter (D/A) and the voltage/current transformer (U/I) into a temperature-linear current signal I A (4 to 20 ma). /6 Siemens FI US Edition
37 Transmitter for field mounting with temperature sensor SITRANS TF2 Digital display thermometer Display The SITRANS TF2 has a 5-digit display behind a glass cover. The following data are shown on the display: measured temperature unit ( C, F, R or K and ma or %) limit violation, indicated by LED and arrow symbols in the display Settings The SITRANS TF2 is set using the input keys behind the glass cover underneath the display. The key "M" is used to selected the operating mode. Following modes of operation are available: Measured value Password Unit of measurement Start of scale and end Upper and lower limit value Offset Output current calibration Upper and lower current saturation limit Electrical damping The other two keys are used to set the values in the individual operating modes. Monitoring Two LED indicators are fitted above the display to monitor the set range and the status: The green LED signals that the measured temperature lies within the set limits. The red LED lights up when the measured temperature lies outside the set limits and when there is an error. Technical specifications Measuring principle Resistance thermometer Pt100 class B acc. to DIN IEC 751 Input Measured variable Temperature Max. measuring range -50 C C ( F) Min. measured span 50 K (90 F) Output Output signal ma, 2-wire Lower current limit min..6 ma Upper current limit max. 2 ma Output protected against reversed polarity, overvoltage and short-circuiting max. load (U H 12 V) / 0.02 A Voltage measurement Temperature-linear Measuring accuracy Error in measurement at 2 C ± 5K (7.4 ± 9 F) Measuring cycle time Temperature effect Power supply effect Vibration influence < ± (0.45 K % of full-scale value in K + 1 digit in K) (< ± (0.81 F % of full-scale value in F + 1 digit in F) 100 ms < ± 0.15 %/10 K (< ± 0.15 %/18 F) < ±0,01 % of full-scale value/v < ±0.05 %/g to 500 Hz in all directions (to IEC ) Rated conditions Ambient conditions Ambient temperature C ( F) Temperature range for best readability C ( F) Storage temperature C ( F) Degree of protection IP65 to EN Electromagnetic compatibility EN 6126/A2 Appendix A (2001) Displays and controls Display LCD, max. 5 digits, digit height 9 mm (0.54 inch) Resolution at max. measuring range 0.01 C (0.01 F) Decimal point Freely parameterizable Limit values Freely parameterizable Limit violation display Red LED and message on LCD ( symbol / symbol in case of limit violation in upward/downward direction) Parameterization With keys Units ma or % or Ω or physical variable: C, F, R, K Damping Between 0.1 and 100 s (increment: 0.1 s) freely parameterizable Design Weight 0.7 kg ( 1.54 lb) Non-wetted parts materials Field housing Diam. 80 mm (diam..15 inch), stainless steel, mat. No Cover Stainless steel, mat. No with glass Wetted parts materials Protective tube To DIN 4772 form 8 (March 2000), diam. 14 x 1.5 mm (diam x 0.06 inch) - Material Stainless steel (mat. No /16Ti) Protective tube screw socket G½B to DIN form A or ½ -14 NPT - Material Stainless steel (mat. No /16Ti) Measuring insert Length to fit the ordered protective tube, stainless steel Connection of display to the protective tube Length of the protective tube(u 1 ) Electrical connection Power supply Terminal voltage on temperature transmitter (U H ) Operating limits Pressure radial (type A), can be swiveled by max. ±120 (α) axial (type B), can be swiveled by max. ± 60 see Ordering data Using 2-pole plug connector made of plastic with M16x1.5-cable entry to EN A or ½ -14 NPT V DC max. 40 bar (580 psi) Siemens FI US Edition /7
38 Transmitter for field mounting with temperature sensor SITRANS TF2 Digital display thermometer Selection and ordering data Order No. Order code Selection and ordering data Temperature transmitter SITRANS TF2, 7 N G Further design field device Temperature transmitter with LCD in stainless steel housing, degree of protection IP65, stainless steel protective tube, resistance thermometer with Pt100 sensor, measuring range C ( F), local parameterization, output signal ma Display/cable entry Radial version (type A), } 1 parallel to protective tube/m16x1.5 Axial version (type B), 2 Additional data at right angles to protective tube/m16x1.5 Radial version (type A), parallel to protective tube/½"-npt Measuring range to be set Axial version (type B), 4 Y01:... at right angles to protective tube/½"-npt Process connection Connection shank G½B } A Connection shank ½"-14 NPT B Other version (on request) Z J 1 Y add Order code and plain text: connection shank:... Schematics Length of the protective tube (U 1 ) 170 mm (6.70 inch) } A 260 mm (10.24 inch) } B 4.5" (114 mm) K 7.5" (190 mm) P 10.5" (266 mm) T Other version (on request) Z K 1 Y add Order code and plain text: length:... Material of the protective tube Stainless steel (mat. No /16Ti) } 0 Other version (on request) 9 L 1 Y add Order code and plain text: mat. No.:... } Available ex stock Manufacturer s test certificate M to DIN 5540, Part 18 and ISO 8402 (calibration certificate points), add "-Z" to Order No. and Order code. Manufacturer s test certificate M to DIN 5540, Part 18 and ISO 8402 (calibration certificate 1 point) supplied later, specify factory no. of transmitter. Add -Z to Order No. and specify Order code and plain text Measuring point label made of stainless steel, please specify inscription in plain text. U B R L I Power supply Load Output current 1 (+) 2 (-) SITRANS TF2, connection diagram I 0 Order code C11 Order No. 7MF1564-8CC11 Order code Y01 Y15 R L + U B Dimensional drawings Ø 82 (.2) SW 27 Ø 80 (.15) M16x1.5 or ½"-NPT Ø 14 (0.55) 45 (1.77) 48,5 (1.91) G½B or ½"-14 NPT M16x1.5 or ½"-NPT 48,5 (1.99) 45 (1.77) SW 27 G½B or ½"-14 NPT Ø 82 (.2) 67 (2.64) U 1 U 1 Type A Type B SITRANS TF2, dimensions in mm (inches) /8 Siemens FI US Edition
39 Transmitter for field mounting with temperature sensor SITRANS TF280 WirelessHART Overview SITRANS TF280 for flexible and cost-effective temperature measurements Supports the WirelessHART standard (HART V 7.1) Very high security level for wireless data transmission Built-in local user interface (LUI) with -button operation Optimum representation and readability using graphical display (104 x 80 pixels) with integrated backlight Stand-by (deep sleep phase) mode can be turned on and off with push of a button Battery power supply Battery life time up to 5 years Extend battery life time with HART modem interface which can be switch off Optimized power consumption through new design, and increase in battery life time Simple configuration thanks to SIMATIC PDM Housing meets IP65 degree of protection Supports all Pt100 sensors as per IEC 751/DIN EN Application The SITRANS TF280 is a WirelessHART field device for temperature measurement with a Pt100 sensor. This sensor can be installed directly on the field device, or connected at an offset with a cable connection. On the wireless communication side, the transmitter supports the WirelessHART standard. A HART modem can be connected to the transmitter particularly for initial parameterization. It can be used in all industries and applications in non-explosive areas. Design The SITRANS TF280 has a robust aluminum enclosure and is suitable for outside use. It conforms with the IP65 safety class. The operation temperature range is -40 to +80 C (-40 to +176 F). Power supply is provided through an integrated battery, which is available as an accessory. The device is only approved for operation with this battery. The antenna features a rotatable joint which can be used for directional alignment. Wireless signals can thus be optimally received and transmitted. A special highlight is the possibility to operate directly on the device with push buttons. It perfectly matches the strategy of all new Siemens field devices. Using the device s push buttons, it is easy to turn the HART modem interface of the device on and off. The device can be put to passive status and reactivated at any time. This helps to extend the life time of the battery. The SITRANS TF280 transmitter features a cable gland or a Pt100 sensor including protective piping. Function The SITRANS TF280 can join to a WirelessHART network. It can be parameterized and operated through this network. Measured process values are transmitted via the network to the SIEMENS IE/WSN-PA LINK. Field device data received by the IE/WSN-PA LINK is transmitted to the connected systems, for example the process control system SIMATIC PCS 7. For an introduction of WirelessHART, please see the FI 01 catalogue Sec. 9 or Detailed information on IE/WSN-PA LINK can be found in the FI 01 catalogue Sec. 9 or Benefits The SITRANS TF280 is a temperature transmitter that features Integration WirelessHART as the standard communication interface. Connecting to SIMATIC PCS 7 Also available is a wired interface to connect a HART modem: Flexible temperature measurement Save costs on wiring at difficult installation conditions. Wireless technology offers cost advantages in cases where extensive wiring costs would normally apply. It enables additional hitherto unfeasible measuring points, particularly for monitoring purposes Easy installation also on moveable equipment parts Enables cost-effective temporary measurements, for example for process optimizations. Optimum solution in addition to wired communication and for system solutions in process automation The integration of field devices in SIMATIC PCS 7 and other process control systems can be now done seamlessly and cost-effectively with wireless technology, especially in situations where high wiring costs may be expected. Of particular interest are measuring points which are to be added and for which no wiring is available. Where larger distances between the IE/WSN-PA LINK and control systems need to be overcome, this connection can also be implemented on a wireless and cost-effective basis using the SCALANCE W series of products. Siemens FI US Edition /9
40 Transmitter for field mounting with temperature sensor SITRANS TF280 WirelessHART Degree of protection IP65/NEMA 4 Industrial Ethernet SITRANS AW200 SITRANS P280 ES OS MS WirelessHART SITRANS TF280 IE/WSN-PA LINK PROFIBUS SIMATIC system SIMATIC ET 200 with HART support DP/PA LINK PROFIBUS PA Max. permissible temperature at transmitter for directly mounted Pt100 Design Enclosure Shock resistance 80 C (176 F) Die-cast aluminum in accordance with DIN EN / 0.95 Resistance to vibration DIN EN / f 2000 Hz 0.01 g²/hz Weight without battery 1.5 kg (. lb) with battery 1.6 kg (.5 lb) Dimensions (W x H x D) See Dimensional drawing Thread for cable gland/ sensor connection M20x1.5 other threads via adapter Integration of a meshed network into SIMATIC PCS 7 Configuration Configuration of the SITRANS TF280 transmitter may be carried out as follows: Initial commissioning for the SITRANS TF280 with SIMATIC PDM is generally carried out via a HART modem or the integrated local user interface, since the network ID and join Key must be set up on the device before it can be accepted and integrated into the WirelessHART network. Once it is integrated into the network, the device can be conveniently operated with the WirelessHART network or onsite with a HART modem or via the local user interface. Technical specifications The SITRANS TF280 can be mechanically installed in two ways: Direct at the measuring point with a M20x1.5 thread. A connection to other threads can be done via the adapter. Remotely from the Pt100 sensor, which is connected to the transmitter via a cable Input Sensor Sensor type Pt100 as per IEC 751/DIN EN Connection Two, three or four-wire system Measuring range C ( F) Cable length SITRANS TF280 and m Pt100 sensor element Measuring accuracy Accuracy < 0.5 % of the measuring range or 0.5 C Long-term drift < 0.05 % of the measuring range in first year Ambient temperature effect < 0.1 C/10 K Rated conditions Ambient temperature C ( F) Storage temperature C ( F) Relative humidity <95% Climatic class 4K4H in accordance with EN (stationary use at locations not protected against weather) Cable between transmitter and sensor element m für two-, three- or four-wire connections Cable resistance < 1 Ω (setting range in mω ) Recognized Sensor break Displays and controls Display (with illumination) Size of display 104 x 80 pixels Number of digits Adjustable Number of spaces after comma Adjustable Setting options on site with push buttons with SIMATIC PDM or HART Communicator Auxiliary power Battery.6 V DC Communication Wireless standard WirelessHART V7.1 conforming Transmission frequency band 2.4 GHz (ISM-Band) Range under reference conditions Up to 250 m (line of sight) in outside areas Up to 50 m (greatly dependent on obstacles) in Inside areas Communication interfaces HART communication with HART modem WirelessHART Certificates and approvals Wireless communication approvals R&TTE FCC Classification according to pressure equipment directive (PED 97/2/EC) This device does not fall under the pressure equipment directive: /40 Siemens FI US Edition
41 Transmitter for field mounting with temperature sensor SITRANS TF280 WirelessHART Selection and ordering data SITRANS TF280 WirelessHART Temperature transmitter (Required battery not included with delivery, see accessories) Connections/cable entry Cable gland M20x1.5 Sensor pipe with Pt100, G½" male thread, pre-mounted and connected Display Order No. } 7 M P A Digital display, visible 1 Enclosure Die-cast aluminum 1 Explosion protection Not included Antenna Variable, attached to device Further designs Order code Please add "-Z" to Order No. and specify Order code(s) and plain text. Measuring point number (TAG Nr.) Y15 max. 16 digits entered in plain text Y15:... Measuring point message Y16 max. 27 characters entered in plain text: Y16:... Accessories Order No. Lithium battery for } 7MP1990-0AA00 SITRANS TF280/P280 Mounting bracket, steel 7MF4997-1AC Mounting bracket, stainless steel } 7MF4997-1AJ Cover, die-cast aluminum, without } 7MF4997-1BB window Cover, die-cast aluminum, with window } 7MF4997-1BE Thread adapter M20x1.5 (male } 7MP1990-0BA00 thread) on ½-14 NP (female thread) 1) Thread adapter M20x1.5 (male } 7MP1990-0BB00 thread) on G½B (female thread) 1) IE/WSN-PA Link see Sec. 9 HART modem with RS22 interface } 7MF4997-1DA HART modem with USB interface } 7MF4997-1DB SIMATIC PDM see Sec. 9 } Available ex stock 1) Available soon C D A A Siemens FI US Edition /41
42 Transmitter for field mounting with temperature sensor SITRANS TF280 WirelessHART Dimensional drawings Siemens AG 2010 Antenna 10 (5.12) 90 SW27 Pt (4.4) 242 (9.5) Ø 80 (.15) 154 (6.06) Ø 80 (.15) 52 (2.05) G½B 101 (.98) Ø 8 (0.2) 14 (0.55) 52 (1.9) SITRANS TF280 WirelessHART temperature transmitter with Pt100, dimensions in mm (inch) /42 Siemens FI US Edition
43 Transmitter for field mounting with temperature sensor SITRANS TF280 WirelessHART Antenna (5.12) 112 (4.4) 242 (9.5) Ø 80 (.15) 154 (6.06) Ø 80 (.15) 52 (2.05) Cable gland for cable mm ( inch) 264 (10.4) SITRANS TF280 WirelessHART temperature transmitter, dimensions in mm (inch) Siemens FI US Edition /4
44 Transmitter for field mounting/field indicator SITRANS TF - Transmitter, two-wire system and - Field indicator for 4 to 20 ma Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable. Benefits Universal use - as transmitter for resistance thermometer, thermoelement, Ω or mv signal - as field indicator for any 4 to 20 ma signals Local sensing of measured values over digital display Rugged two-chamber enclosure in die-cast aluminium or stainless steel Type of protection IP67 Test terminals for direct read-out of the output signal without breaking the current loop Can be mounted elsewhere if the measuring point - is not easily accessible - is subject to high temperatures - is subject to vibrations from the system - or if you want to avoid long neck tubes and/or protective tubes Can be mounted directly on American-design sensors Wide range of approvals for use in potentially explosive atmospheres. "Intrinsically safe, non-sparking and flameproof" type of protection, for Europe and USA. SIL 2 (with order code C20) Function Configuration The communication capability over the HART protocol V 5.9 of the SITRANS TF with an integrated SITRANS TH00 permits parameterization using a PC or HART communicator (hand-held communicator). The SIMATIC PDM makes it easy. Parameterization is carried out using a PC for SITRANS TF - with the integrated and programmable SITRANS TH200. Available for this purpose are a special modem and the software tool SIPROM T. Mode of operation Mode of operation of SITRANS TF as temperature transmitter The sensor signal, whether resistance thermometer, thermocouple or Ω and/or V signal, is amplified and linearized. Sensor and output side are electrically isolated. An internal cold junction is integrated for measurements with thermocouples. The device outputs a temperature-linear direct current of 4 to 20 ma. As well as the analog transmission of measured values from 4 to 20 ma, the HART model also supports digital communication for online diagnostics, measured value transmission and configuration. SITRANS TF automatically detects when a sensor should should be interrupted or is indicating a short-circuit. The practical test terminals allow direct measurement of 4 to 20 ma signals over an ammeter without interrupting the output current loop. Mode of operation of SITRANS TF as field indicator Any 4 to 20 ma signal can be applied to the generous terminal block. As well as a range of predefined measurement units, the adjustable indicator also supports the input of customized units. This means that any 4 to 20 ma signal can be represented as any type of unit, e.g. pressure, flow rate, filling level or temperature. Sensor TC RTD SITRANS TF SITRANS TH Analog-to- digital converter 2 Electrical isolation Microprocessor 4 Digital-to-analog converter 5 Power supply 6 PC/Laptop 7 HART modem 8 Digital display (option) 9 Test connector C A D D μp A 6 Power supply 7 Load Application SITRANS TF can be used everywhere where temperatures need to be measured under particularly adverse conditions, or where a convenient local display is ideal. Which is why users from all industries have opted for this field device. The rugged enclosure protects the electronics. The stainless steel model is even resistant to sea water and other aggressive elements The inner workings offer high measuring accuracy, universal input and a wide range of diagnostic options. Operating principle: SITRANS TF with an integrated transmitter and digital display /44 Siemens FI US Edition
45 Transmitter for field mounting/field indicator SITRANS TF - Transmitter, two-wire system and - Field indicator for 4 to 20 ma Technical specifications Input Resistance thermometer Measured variable Sensor type to IEC to JIS C 1604; a= K-1 to IEC Temperature Pt25... Pt1000 Pt25... Pt1000 Ni25... Ni1000 Units C and F Connection Normal connection Generation of average value Generation of difference Interface Two-wire system Three-wire system Four-wire system Sensor current Response time Open-circuit monitoring Short-circuit monitoring Measuring range Min. measured span Characteristic Resistance-based sensors Measured variable Sensor type Units Connection Normal connection Generation of average value Generation of difference Interface Two-wire system Three-wire system Four-wire system Sensor current Response time Open-circuit monitoring Short-circuit monitoring 1 resistance thermometer (RTD) in 2-wire, -wire or 4-wire system Series or parallel connection of several resistance thermometers in a two-wire system for the generation of average temperatures or for adaptation to other device types 2 resistance thermometers (RTD) in 2-wire system (RTD 1 RTD 2 or RTD 2 RTD 1) Parameterizable line resistance 100 Ω (loop resistance) No balancing required No balancing required 0.45 ma 250 ms for 1 sensor with opencircuit monitoring Can be switched off Can be switched off (value is adjustable) Parameterizable (see table "Digital measuring errors") 10 C (18 F) Temperature-linear or special characteristic Actual resistance Resistance-based, potentiometers Ω 1 resistance-based sensor (R) in 2-wire, -wire or 4-wire system 2 resistance-based sensors in 2-wire system for generation of average value 2 resistance-based sensor in 2-wire system (R 1 R 2 or R2 R1) Parameterizable line resistance 100 Ω (loop resistance) No balancing required No balancing required 0.45 ma 250 ms for 1 sensor with opencircuit monitoring Can be switched off Can be switched off (value is adjustable) Measuring range Parameterizable (see table "Digital measuring errors") Min. measured span Ω (see table "Digital measuring errors") Characteristic Resistance-linear or special characteristic Thermocouple Measured variable Temperature Sensor type (thermocouples) Type B Pt0Rh-Pt6Rh to DIN IEC 584 Type C W5 %-Re to ASTM 988 Type D W %-Re to ASTM 988 Type E NiCr-CuNi to DIN IEC 584 Type J Fe-CuNi to DIN IEC 584 Type K NiCr-Ni to DIN IEC 584 Type L Fe-CuNi to DIN 4710 Type N NiCrSi-NiSi to DIN IEC 584 Type R Pt1Rh-Pt to DIN IEC 584 Type S Pt10Rh-Pt to DIN IEC 584 Type T Cu-CuNi to DIN IEC 584 Type U Cu-CuNi to DIN 4710 Units C or F Connection Standard connection 1 thermocouple (TC) Generation of average value 2 thermocouples (TC) Generation of difference 2 thermocouples (TC) (TC 1 TC 2 or TC 2 TC 1) Response time 250 ms for 1 sensor with opencircuit monitoring Open-circuit monitoring Can be switched off Cold junction compensation Internal With integrated Pt100 resistance thermometer External With external Pt100 IEC (2-wire or -wire connection) External fixed Cold junction temperature can be set as fixed value Measuring range Parameterizable (see table "Digital measuring errors") Min. measured span Min C ( F) (see table "Digital measuring errors") Characteristic Temperature-linear or special characteristic mv Sensor Measured variable DC voltage Sensor type DC voltage source (DC voltage source possible over an externally connected resistor) Units mv Response time 250 ms for 1 sensor with opencircuit monitoring Open-circuit monitoring Can be switched off Short-circuit monitoring Can be switched off (value is adjustable) Measuring range mv mv Min. measured span 2 mv or 20 mv Overload capacity of the input V DC Input resistance 1 MΩ Characteristic Voltage-linear or spec. characteristic Siemens FI US Edition /45
46 Transmitter for field mounting/field indicator SITRANS TF - Transmitter, two-wire system and - Field indicator for 4 to 20 ma Output Output signal ma, 2-wire Communication with to HART Rev. 5.9 SITRANS TH00 Digital display Digital display (optional) in current loop Display max. 5 digits Digit height 9 mm (0.5") Display range Units Any (max. 5 char.) Setting: With keys Zero point, upper range value and unit Load voltage 2.1 V Measuring accuracy Digital measuring errors See table "Dig. measuring errors" Reference conditions Auxiliary power supply 24 V ± 1 % Load 500 Ω Storage temperature 2 C (7.4 F) Warming-up time > 5 min Error in the analog ouput < % of span (digital/analog converter) Error due to internal cold junction < 0.5 C (0.9 F) Temperature effect < 0.1 % of max. span/10 C (18 F) Power supply effect < % of span/v Effect of load impedance < % of span/100 Ω Long-term drift in the first month < 0.02 % of max. span after one year < 0.2 % of max. span after 5 years < 0. % of max. span Rated conditions Ambient temperature Storage temperature C ( F) Condensation Permissible Electromagnetic compatibility According to EN 6126 and NAMUR NE21 Degree of protection to EN IP67 Design Approx. weight Approx. 1.5 kg (. lb), without options Dimensions See "Dimensional drawings" Enclosure material Die-cast aluminum, low in copper, GD-AlSi 12 or stainless steel, polyester-based lacquer, stainless steel rating plate Electrical connection, sensor connection Mounting bracket (optional) Power supply Without digital display Screw terminals, cable inlet via M20 x 1.5 or ½-14 NPT threaded gland Steel, galvanized and chromeplated or stainless steel V DC (0 V with Ex) Certificate and approvals Explosion protection ATEX "Intrinsically-safe" type of protection With digital indicator: II 2 (1) G EEx ia IIC T4 Without digital indicator: II 2 (1) G EEx ia IIC T6 - EC type test certificate ZELM 99 ATEX 0007 "Operating equipment that is II G EEx nal IIC T6/T4 non-sparking and has limited energy for zone 2" type of protection - EC type test certificate ZELM 99 ATEX 0007 Flame-proof enclosure" type of II 2 G EEx d IIC T5/T6 protection - EC type test certificate CESI 99 ATEX 079 Explosion protection to FM Certificate of Compliance Identification (XP, DIP, NI, S) XP / I / 1/BCD / T5 Ta = 85 C (185 F), T6 Ta = 50 C (112 F), Type 4X DIP / II, III / 1 / EFG / T5 Ta = 85 C (185 F), T6 Ta = 50 C (112 F), Type 4X NI / I / 2 / ABCD / T5 Ta = 85 C (185 F), T6 Ta = 50 C (112 F), Type 4X S / II, III / 2 / FG / T5 Ta = 85 C (185 F), T6 Ta = 50 C (112 F), Type 4X Hardware and software requirements For the parameterization software SIPROM T for SITRANS TH200 - Personal computer PC with CD-ROM drive and USB/RS 22 interface - PC operating system Windows 98, NT, 2000, XP For the parameterization software See chapter 9, "Software", SIMATIC PDM for SITRANS TH00 "SIMATIC PDM" Communication Load for HART connection Ω Two-core shielded.0 km (1.86 mi) Multi-core shielded 1.5 km (0.9 mi) Protocol HART protocol, version 5.x Factory setting (transmitter): Pt100 (IEC 751) with three-wire circuit Measuring range: C ( F) Fault current 22.8 ma Sensor offset: 0 C (0 F) Damping 0.0 s With digital display Electrically isolated Test voltage V DC (0 V with Ex) Between input and output U eff = 1 kv, 50 Hz, 1 min /46 Siemens FI US Edition
47 Digital measuring errors Resistance thermometer Input Measuring range Min. measured span Resistance-based sensors Input Measuring range Min. measured Digital span accuracy Ω Ω Ω Resistance ,05 Resistance ,25 Transmitter for field mounting/field indicator SITRANS TF - Transmitter, two-wire system and - Field indicator for 4 to 20 ma Digital accuracy C ( F) C ( F) C ( F) according to IEC Pt (18) 0,2 (0.6) ( ) Pt (18) 0,15 (0.27) ( ) Pt Pt (18) 0,1 (0.18) ( ) Pt (18) 0,15 (0.27) ( ) Pt ( ) 10 (18) 0,15 (0.27) according to JIS C Pt (18) 0,2 (0.6) ( ) Pt (18) 0,15 (0.27) ( ) Pt Pt (18) 0,1 (0.18) ( ) Pt (18) 0,15 (0.27) ( ) Pt (18) 0,15 (0.27) ( ) Ni Ni ( ) 10 (18) 0,1 (0.18) Siemens AG 2010 Thermocouple elements Input Measuring range Min. measured span Digital accuracy C ( F) C ( F) C ( F) Type B (180) 2 1) (.60) 1) ( ) Type C (W5) (180) 2 (.60) ( ) Type D (W) (180) 1 2) (1.80) 2) ( ) Type E (90) 1 (1.80) ( ) Type J (90) 1 (1.80) ( ) Type K (90) 1 (1.80) ( ) Type L (90) 1 (1.80) ( ) Type N (90) 1 (1.80) ( ) Type R (180) 2 (.60) ( ) Type S (180) 2 (.60) ( ) Type T (72) 1 (1.80) ( ) Type U ( ) 50 (90) 2 (.60) 1) The digital accuracy in the range 0 to 00 C (2 to 572 F) is C (5.4 F). 2) The digital accuracy in the range 1750 to 200 C (182 to 4172 F) is 2 C (.6 F). mv sensors Input Measuring range Min. measured span mv mv μv mv sensors mv sensors Digital accuracy The digital accuracy is the accuracy after the analog/digital conversion including linearization and calculation of the measured value. An additional error is generated in the output current 4 to 20 ma as a result of the digital/analog conversion of 0.1 % of the set span (digital-analog error). The total error under reference conditions at the analog output is the sum from the digital error and the digital-analog error (poss. with the addition of cold junction errors in the case of thermocouple measurements). Siemens FI US Edition /47
48 Transmitter for field mounting/field indicator SITRANS TF - Transmitter, two-wire system and - Field indicator for 4 to 20 ma Dimensional drawings Siemens AG (0.51) 144 (5.67) 15* (0.59) 18* (5.4) 52 (2.05) 50* (1.97) 55 (2.17) 28 (1.10) 20 (0.79) b 80 (.15) 100* (.94) (.15) 8 a: max. 164 (6.46) (M20x1.5) max. 189 (7.44) (½-14 NPT) b: max. 25 (0.98) (M20x1.5) max. 50 (1.97) (½-14 NPT) *) Dimensions for stainless steel enclosure (2.8) 12 (4.84) Æ ( ) 50 (1.97) 768 (2.68) 117 (4.61) 120 (4.72) a 6,5 (1.44) 27 (9.) 1 Sensor connection (screwed gland M20x1,5 or ½-14 NPT) 2 Blanking plug Electrical connection (screwed gland M20x1,5 or ½-14 NPT) 4 Terminal side, output signal 5 Terminal side, sensor 105 (4.1) 6 Protective cover (without function) 7 Mounting bracket (option) with clamp for securing to a vertical or horizontal pipe 8 Cover with window for digital display SITRANS TF, dimensions in mm (inches) /48 Siemens FI US Edition
49 Transmitter for field mounting/field indicator SITRANS TF - Transmitter, two-wire system and - Field indicator for 4 to 20 ma Selection and Ordering data Order No. Temperature transmitter in field housing D) 7 N G Two-wire system ma, with electrical isolation, with documentation on CD-ROM Integrated transmitter SITRANS TH200, programmable - without Ex protection with EEx ia with EEx nal for zone total device SITRANS TF EEx d 1) total device SITRANS TF according to FM 5 5 (XP, DIP, NI, S) 1) SITRANS TH00, communication capability according to HART V without Ex-protection with EEx ia with EEx nal for zone total device SITRANS TF EEx d 1) total device SITRANS TF according to FM 6 5 (XP, DIP, NI, S) 1) SITRANS TF field indicator 7 N G for ma signals, with documentation on CD-ROM without Ex-protection with EEx ia with EEx nal for zone total device SITRANS TF EEx d 1) total device SITRANS TF according to FM (XP, DIP, NI, S) 1) Enclosure die-cast aluminium A stainless steel precision casting E Connections/cable inlet screwed glands M20x1.5 B screwed glands ½-14 NPT C Digital indicator without 0 with 1 Mounting bracket and securing parts without 0 made of steel 1 made of stainless steel 2 Further designs Order code Please add "-Z" to Order No. and specify Order code(s) and plain text. Customer-specific setting of operating data Y 0 1 2) Inscription on measuring-point label measuring range (max. 27 characters) Y2 2 ) meas. point description (max. 16 char.) Y2 ) measuring point text (max. 27 char.) Y2 4 ) Test protocol (5 measuring points) C11 4) SIL 2 (functional safety) C 2 0 5) Power supply units see "SITRANS I supply units and input isolators". 1) Without cable gland. 2) Y01: Please specify all data that does not correspond to factory settings (see above) (e.g. Y01 = thermocouple element type K; internal cold junction; C; fault current.6 ma). ) Y22, Y2, Y24: If no order is placed for Y01, these data are only noted on the measuring point label and are not programmed in the transmitter. 4) Can only be ordered together with Y01. 5) Only with 7NG and 7NG Selection and Ordering data Order No. Accessories Modem for SITRANS TH200 incl. parameterization software T with USB interface } 7NG092-8KU C) with RS 22 interface } 7NG092-8KM C) CD for measuring instruments } A5E for temperature with documentation in German, English, French, Spanish, Italian and Portuguese, and parameterization software SIPROM T (included in delivery with SITRANS TF) HART modem with RS 22 interface } 7MF4997-1DA D) with USB interface } 7MF4997-1DB D) SIMATIC PDM parameterization software see chap. 9 also for SITRANS TH00 Mounting bracket and securing parts made of steel for 7NG1.-..B.. 7MF4997-1AC made of steel for 7NG1.-..C.. 7MF4997-1AB made of stainless steel for 7NG1.-..B.. } 7MF4997-1AJ made of stainless steel for 7NG1.-..C.. 7MF4997-1AH Digital indicator 1) 7MF4997-1BS Connection board A5E } Available ex stock. Power supply units see "SITRANS I supply units and input isolators". 1) It is not possible to upgrade devices with Ex protection C) Subject to export regulations AL: N, ECCN: EAR99. D) Subject to export regulations AL: N, ECCN: EAR99H. Factory setting (transmitter): Pt100 (IEC 751) with three-wire circuit Measuring range: C ( F) Fault current 22.8 ma Sensor offset: 0 C (0 F) Damping 0.0 s Siemens FI US Edition /49
50 Transmitter for field mounting/field indicator SITRANS TF - Transmitter, two-wire system and - Field indicator for 4 to 20 ma Schematics Siemens AG 2010 Resistance thermometer Resistance Thermocouple Two-wire system 1) Two-wire system 1) Cold junction compensation Internal/fixed value Three-wire system Three-wire system Cold junction compensation with external Pt100 in two-wire system 1) Four-wire system Four-wire system Cold junction compensation with external Pt100 in three-wire system Generation of average value / difference 1) 1) Programmable line resistance for the purpose of correction. Generation of average value / difference 1) Generation of average value / difference with internal cold junction compensation Voltage measurement Current measurement SITRANS TF, sensor connection assignment /50 Siemens FI US Edition
51 Transmitter for field mounting with temperature sensor SITRANS TF fieldbus transmitter Overview Application The SITRANS TF can be used everywhere where temperatures need to be measured under particularly harsh conditions. Which is why users from all industries have opted for this field device. The rugged enclosure protects the electronics. The stainless steel model is even resistant to sea water and other aggressive elements. The inner workings offer high measuring accuracy, universal input and a wide range of diagnostic options. Our field devices for heavy industrial use FOUNDATION fieldbus PROFIBUS PA The SITRANS TF temperature transmitter works where others can t cope. Benefits For universal use as a transmitter for resistance thermometers, thermocouple elements, Ω or mv signals Rugged two-chamber enclosure in die-cast aluminium or stainless steel Degree of protection IP67 Can be mounted elsewhere if the measuring point - is not easily accessible - is subject to high temperatures - is subject to vibrations from the system - or if you want to avoid long neck tubes and/or protective tubes Can be mounted directly on American-design sensors Wide range of approvals for use in potentially explosive atmospheres. "Intrinsically safe, non-sparking and flameproof" type of protection, for Europe and USA Function Features General Polarity-neutral bus connection 24-bit analog-digital converter for high resolution Electrically isolated Version for use in hazardous areas Special characteristic Sensor redundance Transmitter with PROFIBUS PA communication Function blocks: 2 x analog Transmitter with FOUNDATION fieldbus communication Function blocks: 2 x analog and 1 x PID Functionality: Basic or LAS Mode of operation The following function diagram explains the mode of operation of the transmitter. The only difference between the two versions of the SITRANS TF (7NG and 7NG18-...) is the type of field bus protocol used (PROFIBUS PA or FOUNDATION fieldbus). Optional inputs: - Resistance thermometer - Thermocouple - mv sensor - Resistance-based sensors Transformer Input 1 Input 2 Differential Mean value Redundancy Terminal temperature Engineering units Diagnostic functions Table linearization Polynomial linearization Process calibration 6 Electrically isolated Input 1 Input A/D converter CPU Communication Ex power circuit 1 2 Bus connection Internal Pt100 EEPROM Complex configuration Correction coefficient Factory settings - PROFIBUS PA protocol (7NG17) or - FOUNDATION Fieldbus protocol (7NG18) SITRANS TF with TH400, function diagram Siemens FI US Edition /51
52 Transmitter for field mounting with temperature sensor SITRANS TF fieldbus transmitter System communication Bus terminator Bus terminator SITRANS TF with TH400 PA SITRANS TF with TH400 FF SITRANS TF with TH400, communication interface Technical specifications Input Analog/digital conversion Measurement rate Resolution Resistance thermometer Pt25... Pt1000 to IEC 60751/JIS C 1604 Measuring range Ni25... Ni1000 to DIN 4760 Measuring range Cu10... Cu1000, α = Measuring range Line resistance per sensor cable Sensor current Sensor fault detection Sensor break detection Sensor short-circuit detection Resistance-based sensors Measuring range Line resistance per sensor cable Sensor current Sensor fault detection Sensor break detection Sensor short-circuit detection <50ms 24-bit C ( F) C ( F) C ( F) Max. 50 Ω Nominal 0.2 ma Yes Yes, < 15 Ω 0 Ω kω Max. 50 Ω Nominal 0.2 ma Yes Yes, < 15 Ω PROFIBUS PA Segment coupler FOUNDATION Fieldbus Segment coupler Thermocouple To IEC 584 Type B Type E Type J Type K Type N Type R Type S Type T to DIN 4710 Type L Type U to ASTM E Type W Type W5 External cold junction compensation Sensor fault detection Sensor break detection Sensor short-circuit detection Sensor current in the event of open-circuit monitoring mv sensor - voltage input Measuring range Input resistance Output Filter time (programmable) Update time Measuring accuracy Accuracy is defined as the higher value of general values and basic values. General values Type of input All Measuring range C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) Yes Yes, < mv 4 μa mv 10 MΩ s < 400 ms Absolute accuracy ±0.05 % of measured value Temperature coefficient ±0.002 % of measured value/ C Basic values Type of input Basic accuracy Temperature coefficient Pt100 and Pt1000 ±0.1 C ±0.002 C/ C Ni100 ±0.15 C ±0.002 C/ C Cu10 ±1. C ±0.02 C/ C Resistance-based sensors ±0.05 Ω ±0.002 Ω/ C Voltage source ±10 μv ±0.2 μv/ C Thermocouple, type: ±0.5 C ±0.01 C/ C E, J, K, L, N, T, U Thermocouple, type: ±1 C ±0.025 C/ C B, R, S, W, W5 Cold junction compensation ±0.5 C /52 Siemens FI US Edition
53 Transmitter for field mounting with temperature sensor SITRANS TF fieldbus transmitter Reference conditions Warming-up time 0 s Signal-to-noise ratio Min. 60 db Calibration condition C ( F) Conditions of use Ambient conditions Permissible ambient temperature C ( F) Permissible storage temperature C ( F) Relative humidity 98 %, with condensation Insulation resistance Test voltage 500 V AC for 60 s Continuous operation 50 V AC/75 V DC Electromagnetic Compatibility NAMUR NE21 EMC 2004/108/EC Emission and EN , EN Noise Immunity Design Weight Approx. 1.5 kg (. lb) without options Dimensions See "Dimensional drawings" Enclosure materials Die-cast aluminium, low in copper, GD-AlSi 12 or stainless steel Polyester-based lacquer for GD AlSi 12 enclosure Stainless steel rating plate Electrical connection, screw terminals sensor connection Cable inlet via M20 x 1.5 or ½-14 NPT screwed gland Bus connection with M12 plug (optional) Mounting bracket (optional) Steel, galvanized and chromeplated or stainless steel Degree of protection IP67 to EN Auxiliary power supply Power supply Standard, Ex "d", Ex "na", Ex "nl", V DC XP, NI Ex "ia", Ex "ib" V DC In FISCO/FNICO installations V DC Power consumption < 11 ma Max. increase in power consumption in the event of a fault < 7 ma Certificates and approvals Explosion protection ATEX EC type test certificate ZELM 99 ATEX 0007 Type of protection II 2(1) G Ex ia IIC T4/T6 "intrinsic safety i" (version: 7NG1x-1xxxx) Conformity statement ZELM 07 ATEX 49 "Operating equipment that is nonignitable and has limited energy" type of protection (version: 7NG1x-2xxxx) II G Ex na [nl] IIC T4/T6 II G Ex nl IIC T4/T6 EC type test certificate CESI 99 ATEX 079 "Flame-proof enclosure" type of II 2 G Ex d IIC T5/T6 protection (version: 7NG1x- 4xxxx) Explosion protection: FM for USA FM approval FM Type of protection XP, DIP, NI and S (version 7NG1x-5xxxx) XP / I / 1 / BCD / T5,T6; Type 4X DIP / II, III / 1 / EFG / T5,T6; Type 4X NI / I / 2 / ABCD / T5,T6; Type 4X S / II, III / 2 / FG T5,T6; Type 4X Communication Parameterization interface PROFIBUS PA connection - Protocol A&D profile, Version.0 - Protocol EN Volume 2 - Address (for delivery) Function blocks 2 x analog FOUNDATION fieldbus connection - Protocol FF protocol - Protocol FF design specifications - Functionality Basic or LAS - Version ITK Function blocks 2 x analog and 1 x PID Factory setting For SITRANS TH400 PA Sensor Pt100 (IEC) Type of connection -wire circuit Unit C Failure mode Last valid value Filter time 0 s PA address 126 PROFIBUS Ident No. Manufacturer-specific For SITRANS TH400 FF Sensor Pt100 (IEC) Type of connection -wire circuit Unit C Failure mode Last valid value Filter time 0 s Node address 22 Siemens FI US Edition /5
54 Transmitter for field mounting with temperature sensor SITRANS TF fieldbus transmitter Selection and ordering data Order No. Temperature transmitter in field enclosure 7 N G with fieldbus communication and electrical isolation, with documentation on CD Integrated transmitter SITRANS TH400 with PROFIBUS PA - without Ex protection with EEx ia (ATEX) with EEx nal for zone 2 (ATEX) total device SITRANS TF EEx d 1) total device SITRANS TF according to FM 7 5 (XP, DIP, NI, S) 1) (available soon) SITRANS TH400, with FOUNDATION fieldbus - without Ex protection with EEx ia (ATEX) with EEx nal for zone 2 (ATEX) total device SITRANS TF EEx d 1) total device SITRANS TF according to FM 8 5 (XP, DIP, NI, S) 1) (available soon) Enclosure die-cast aluminium A stainless steel precision casting E Connections/cable inlet screwed glands M20x1.5 B screwed gland s ½-14 NPT C Mounting bracket and fastening parts none 0 made of steel 1 stainless steel 2 Further designs Order code Please add "-Z" to Order No. and specify Order code(s) and plain text. Customer-specific operating data Y0 1 2) Inscription on measuring point label Measuring point number/tag (max. 2 char.) Y 1 5 ) Measuring point description (max. 2 char.) Y 2 ) Bus address Y 2 5 ) Test report (5 measuring points) C1 1 4) Bus connection M12 plug (metal), without mating connector M 0 0 5) M12 plug (metal), with mating connector M 0 1 5) 1) Without cable gland. 2) Y01: Please specify all data that does not correspond to factory settings (see above) (e.g. Y01 = thermocouple element type K; internal cold junction; PA address: 15). ) Y15, Y2, Y25: If no order is placed for Y01, these data are only noted on the measuring point label and are not programmed in the transmitter. 4) Can only be ordered together with Y01 (it is essential to specify the measuring range). 5) Not available for explosion protection EEx d or XP. Selection and ordering data Order No. Accessories CD for measuring instruments for temperature A5E with documentation in German, English, French, Spanish, Italian and Portuguese, and parameterization software SIPROM T (included in delivery with SITRANS TF) SIMATIC PDM parameterization software see Sec. 9 also for SITRANS TF with TH400 PA Mounting bracket and fastening parts Made of steel for 7NG1.-..B.. 7MF4997-1AC Made of steel for 7NG1.-..C.. 7MF4997-1AB Made of stainless steel for 7NG1.-..B.. } 7MF4997-1AJ Made of stainless steel for 7NG1.-..C.. 7MF4997-1AH Connection board A5E }Available ex stock. Factory setting: for SITRANS TH400 PA: - Pt100 (IEC) with -wire circuit - Unit: C - Failure mode: last valid value - Filter time: 0 s - PA address: PROFIBUS Ident No.: manufacturer-specific for SITRANS TH400 FF: - Pt100 (IEC) with -wire circuit - Unit: C - Failure mode: last valid value - Filter time: 0 s - Node address: 22 /54 Siemens FI US Edition
55 Transmitter for field mounting with temperature sensor SITRANS TF fieldbus transmitter Dimensional drawings 144 (5.67) 18* (5.4) 52 (2.05) 50* (1.97) 55 (2.17) 28 (1.10) 20 (0.79) b 80 (.15) 100* (.94) 6 2 Ø 80 (.15) (2.8) 50 (1.97) 117 (4.61) 68 (2.68) 120 (4.72) a 6,5 (1.44) 27 (9.) 12 (4.84) Ø ( ) 1 Sensor connection (screwed gland M20x1,5 or ½-14 NPT) 2 Blanking plug Electrical connection (screwed plug M20x1,5 orr ½-14 NPT), optional M12 plug 4 Terminal side, bus connection (4.1) 5 Terminal side, sensor 6 Protective cover (without function) 7 Mounting bracket (optional) with clamp securing to a vertical or horizontal pipe SITRANS TF with TH400, dimensions in mm (inches) Siemens FI US Edition /55
56 Transmitter for field mounting with temperature sensor SITRANS TF fieldbus transmitter Schematics Siemens AG 2010 Resistance thermometer Thermocouple Resistance Two-wire system 1) + - Internal cold junction compensation Two-wire system 1) + - Three-wire system Cold junction compensation with external Pt100 in two-wire system 1) Three-wire system + - Four-wire system Cold junction compensation with external Pt100 in three-wire system Four-wire system Mean-value/differential or redundancy generation 2 x two-wire system 1) Mean value, differential or redundancy generation with internal cold junction compensation Mean value, differential or redundancy generation 1 resistor in two-wire system 1) 1 resistor in three-wire system Voltage measurement Mean-value/differential or redundancy generation 1 sensor in two-wire system 1) 1 sensor in three-wire system Mean value, differential or redundancy generation and cold junction compensation with internal Pt100 in two-wire system 1) + - One voltage source 1) Programmable line resistance for the purpose of correction Measurement of mean value, differential and redundancy with 2 voltage sources SITRANS TF with TH400, sensor connection assignment /56 Siemens FI US Edition
FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex
Data Sheet 0/-8.5 EN FieldIT Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit)
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
J TB/TW Temperature limiter, temperature monitor
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: [email protected] Internet: www.jumo.net
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
Combining perfect senses and intelligence for every degree and condition
siemens.com/sitranst Combining perfect senses and intelligence for every degree and condition SITRANS T: highly accurate temperature sensors and transmitters with unique communication capabilities Answers
Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219
Siemens AG 2010 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
Rosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 [email protected] www.valcontrols.
HARDWARE MANUAL Ixx24-A 1/20 Table of contents 1 General... 3 1.1 Safety instructions... 3 1.2 Environment... 3 1.3 Mounting and dimension... 3 2 Communication... 4 2.1 Control loop AI0 and Transmitter
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
Temperature Transmitters ZTT series
BT.11.13 ZT/E Transmitters ZTT series The ZTT Series transmitters accept the most commonly used temperature sensors (TC and RTD), as well as mv and slidewire feedback signals. All ZTT transmitters provide
TTH300 Head-mount temperature transmitter
Operating Instruction OI/TTH300-EN Rev. D TTH300 Head-mount temperature transmitter Measurement made easy Change from one to two columns Short product description Head-mount temperature transmitter for
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC
E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
Rosemount 333 HART Tri-Loop
Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
TEIP11 I/P signal converter for standard signals. Measurement made easy
Data Sheet 10/18-0.11-EN Rev. B TEIP11 I/P signal converter for standard signals Measurement made easy Current in air pressure Proven and reliable concept Compact design Small dimensions, low weight Sturdy
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
Differential Charge Amplifier
Electronics Differential Type 58A... The differential charge amplifier is used for signal conversion of piezoelectric sensors with differential output. Executions Aluminum die-cast enclosure (IP64) Plastic
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
Instruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
Siemens AG 2010. Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.
Fieldbus solutions with the SIMATIC PCS 7 distributed control system Brochure April 2010 SIMATIC PCS 7 Answers for industry. Fieldbus solutions with SIMATIC PCS 7 OS multi-clients Engineering station Maintenance/
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
LOGO! Logic module. Brochures For brochures serving as selection guides for SIMATIC products refer to: http://www.siemens.com/simatic/ printmaterial
Siemens AG 010 / / SIPLUS basic versions /5 SIPLUS Pure versions /8 analog expansion modules /9 SIPLUS expansion modules Brochures For brochures serving as selection guides for SIMATIC products refer to:
APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement
For Gauge And Absolute Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
Solenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
APPLICATION NOTES OF SIGNAL ISOLATORS
APPLICATION NOTES OF SIGNAL ISOLATORS Summary of Topics Page 一 General Characteristics of Signal Isolator 二 The reasons and solutions about interfere 三 Comparison of supplied by loop circuit, extra power,
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Ammeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
Analog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.
egment Protector for Cabinet nstallation Features Assembly 4... 12 outputs Ex ic (FCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur egment Protector in Zone 2/Div. 2 nstruments
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
1788 Linking Device Specifications
Technical Data 1788 Linking Device Specifications Catalog Numbers 1788-EN2DNROM, 1788-EN2DNR, 1788-EN2FFR, 1788-EN2PAR, 1788-CN2DN, 1788-CN2FFR, 1788-CN2PAR, 1788-FBJB4R, 1788-FBJB6 Topic Page 1788-EN2DNR
OZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
Isolating Barriers for our sensors A5S1 in Ex-areas Series D461
D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
Digital display DA 48
Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital
Plug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Measuring temperature with Resistance Temperature Detectors (RTD) (e.g., Pt100) and thermocouples
Measuring temperature with Resistance Temperature Detectors (RTD) (e.g., Pt100) and thermocouples White Paper By Prof. Dr.-Ing. Klaus Metzger In the area of physical measurement technology, temperature
CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips
January 2014 Description The universal CPA PC-Programmable Alarms provide on/off control, warn of unwanted process conditions, and provide emergency shutdown. Very economical, they accept a direct signal
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
Technical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
JUMPFLEX 857 Series. 0...20 ma 2...10 V. 4...20 ma. Transducers / Relay and Optocoupler Modules
0888-0172/0002-3601 JUMPFLEX 857 Series 2.0 E 12/08 Printed in Germany Subject to design changes 2...10 V 0...20 ma 4...20 ma WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 32385 Minden Hansastraße 27
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
Technical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
Technical Data Sheet. 3DLevelScanner
Changing the market from level to volume Technical Data Sheet APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
Software and Display instruments
Software and Display instruments 272 Overview Software and Display instruments 276 VEGA Inventory System 278 DTM Collection und PACTware 279 VEGACONNECT 280 PLICSCOM, PLICSLED 282 VEGADIS 81, 82, 176 271
ph/redox Measurement MyPro CPM 431
Technical Information TI 173C/07/en/06.02 50088309 ph/redox Measurement MyPro CPM 431 Two-wire transmitter for ph and redox with Hart and PROFIBUS-PA communication for use in Ex and non-ex areas Application
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
1756 ControlLogix Chassis Specifications
Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,
Ammeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A
6ES7313-5BF03-0AB0 Page 1 Product data sheet 6ES7313-5BF03-0AB0 SIMATIC S7-300, CPU 313C, COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO 1 PT100, 3 FAST COUNTERS (30 KHZ), INTEGRATED 24V DC POWER SUPPLY,
PROCESS AUTOMATION MANUAL. Universal Temperature Converter. KFD2-UT2-(Ex)*(-1) ISO9001
PROCESS AUTOMATION MANUAL Universal Temperature Converter KFD2-UT2-(Ex)*(-1) ISO9001 With regard to the supply of products, the current issue of the following document is applicable: The General Terms
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
4-Channel Thermometer / Datalogger
USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter
High-precision valve control using intelligent positioners. sipart
High-precision valve control using intelligent positioners sipart The SIPART PS2 electropneumatic positioner is number 1 in its field by a very wide margin. Our past experience gathered from 10 years in
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
TTH300 Head-mount temperature transmitter
Change from one to two columns Data Sheet DS/TTH300-EN Rev. D TTH300 Head-mount temperature transmitter Temperature transmitter for all communication protocols. ABB common operating concept. Redundancy
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Measuring Temperature withthermistors a Tutorial David Potter
NATIONAL INSTRUMENTS The Software is the Instrument Application Note 065 Measuring Temperature withthermistors a Tutorial David Potter Introduction Thermistors are thermally sensitive resistors used in
SINEAX U553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.
Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300
SIMATIC SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300 Manual Preface, Contents Characteristics and Technical Specifications of the SM 335 Connecting the Inputs and Outputs of the
Inductive slot sensor
0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush