Square D Clipsal 110 Outdoor PIR Motion Sensor

Size: px
Start display at page:

Download "Square D Clipsal 110 Outdoor PIR Motion Sensor"

Transcription

1 Square D Clipsal 110 Outdoor PIR Motion Sensor SLC5750WPL for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use.

2 Square D Clipsal 110 Outdoor PIR Motion Sensor A2 Instruction Bulletin 11/2007 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service, or maintain it. The following special messages may appear throughout this bulletin or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of either symbol to a Danger or Warning safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Danger indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, can result in death or serious injury. Caution indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury. Caution, used without the safety alert symbol, indicates a potentially hazardous situation which, if not avoided, can result in property damage or improper operation. NOTE: Provides additional information to clarify or simplify a procedure Schneider Electric. All Rights Reserved.

3 A2 Square D Clipsal 110 Outdoor PIR Motion Sensor 11/2007 Instruction Bulletin PLEASE NOTE Class B FCC Statement Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. This document is not intended as an instruction manual for untrained persons. No responsibility is assumed by Square D for any consequences arising out of the use of this manual. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help Schneider Electric. All Rights Reserved. 3

4 Square D Clipsal 110 Outdoor PIR Motion Sensor A2 Instruction Bulletin 11/2007 INTRODUCTION Before You Begin This bulletin provides instructions for installing the Square D Clipsal Outdoor PIR Motion Sensor. The SLC5750WPL outdoor motion sensor is a ruggedly built C-Bus input unit that can be mounted on a vertical or horizontal surface. The unit uses a passive infrared receiver (PIR) to detect thermal-based radiation emitted from a moving body, covering up to 3000 ft² (279 m²) with a 110 field of view. Advanced circuits and a flat multi-segmented lens ensure immediate reaction to body movement and few dead zones. The PIR motion sensor works in conjunction with a built-in light-level sensor, issuing commands only when movement is detected and the ambient light-level falls below the pre-set light-level threshold (see section Sensor Operations ). The C-Bus Toolkit software is used to configure the options, which include an adjustable time-out for the PIR; Sunrise/Sunset settings with time delay for the light-level sensor; and a status indicator LED. Before installing an outdoor PIR motion sensor, verify that your order is complete by comparing the contents of the package with the list in the table "Contents of the Box." Also verify that the catalog number on the box label matches your order. NOTE: The outdoor PIR sensor has a cardboard lens protector that should be left in place until it is time to test the unit Schneider Electric. All Rights Reserved.

5 A2 Square D Clipsal 110 Outdoor PIR Motion Sensor 11/2007 Instruction Bulletin Table 1: Contents of the Box Part Number Description Quantity SLC5750WPL 110 Outdoor PIR Motion Sensor 1 Screwdriver for adjusting light levels 1 Lens protector, cardboard (on sensor window) 1 Weather-resistant seal 1 Terminal block 1 Mounting screws 2 Foam gasket 1 Screw-hole caps 3 Insulated bootlace terminals 4 (2 needed, 2 extra) OVERVIEW The motion sensor consists of a sensor head with a pre-wired lead, an adjustable neck assembly, and a mounting base. The sensor head contains the PIR sensor window, sensor mechanisms, status indicator LED, and light-level sensor-adjustment screw. An adjustable neck assembly enables changing the orientation of the sensor, and the base is used for mounting. A weather-resistant seal fitting assembly protects the connections Schneider Electric. All Rights Reserved. 5

6 Square D Clipsal 110 Outdoor PIR Motion Sensor A2 Instruction Bulletin 11/2007 Figure 1: Components of the Sensor Unit KEY: A. Sensor B. Adjustable neck assembly C. Mounting base D. Holes for mounting screws E. Threaded entries for weatherresistant seal fitting assembly F. Sensor lead G. Light-level sensor-adjustment screw H. PIR sensor window Features Continuous 110 detection field results from a multi-faceted lens and field of view composed of 48 detection zones over 4 layers Rugged construction, suitable for outdoor use Adjustable neck assembly for horizontal or vertical mounting Pre-wired flexible cord for easy mounting Light-level sensor has Sunrise/Sunset settings, clock overrides, and adjustable sensitivity (0.1 footcandle to full sunlight) Status indicator LED to indicate motion detection Advanced circuitry helps prevent false triggering Controls up to four C-Bus group addresses that can be independent Receives data and power over a single C-Bus network cable, so the sensors do not require power packs or line-voltage connections Schneider Electric. All Rights Reserved.

7 A2 Square D Clipsal 110 Outdoor PIR Motion Sensor 11/2007 Instruction Bulletin Sensor Operations Two conditions must be met before the occupancy sensor will issue commands to the output units: The motion sensor must detect movement and the light-level sensor must detect levels of ambient light that are below the threshold that has been set. If movement is detected but the ambient light level is not below the light-level threshold, the sensor unit will not issue a command to output units. Also, if the light-level is below the threshold but the PIR does not detect movement, no command will be issued. The motion sensor and light-level sensor have time settings that can be configured with the C-Bus Toolkit software. A time-out setting for the PIR controls how long the unit waits to turn off the load when there has been no movement. A time-delay adjustment for the Sunrise/Sunset setting can be used to control a separate group address from that used by the PIR. The time-delay adjustment determines how long a load will remain on when light levels fall below the threshold. Field of View The unit s motion sensor has a detection range of 3000 ft² (279 m²) and a 110 field of view. The motion sensor has a continuous detection field composed of 48 overlapping detection zones. These zones are distributed in 4 layers extending over the range of coverage: a layer of 4 Ultra Short zones are active at 4 ft from the sensor, a layer of 10 Short zones are active at 13 ft from the sensor, a layer of 16 Intermediate zones are active at 25 ft from the sensor, and a layer of 18 Long zones are active at 59 ft from the sensor (see the table Coverage Layers and Nominal Range of Coverage and the associated field of view figures). Table 2: Coverage Layers and Nominal Range of Coverage Layer Number of Zones Nominal Range* Ultra Short 4 4 ft (1.2 m) Short ft (4 m) Intermediate ft (8 m) Long ft (18 m) *Based on a sensor mounted at 8 ft (2.4 m) 2007 Schneider Electric. All Rights Reserved. 7

8 Square D Clipsal 110 Outdoor PIR Motion Sensor A2 Instruction Bulletin 11/2007 Figure 2: Field of View (from top) KEY: 3. Coverage layers and nominal ranges - Ultra Short: 4 ft (1.2 m) - Short: 13 ft (4 m) - Intermediate: 25 ft (8 m) - Long: 59 ft (18 m) B. Sensor C. Length of detection field D. Optimal approach path Figure 3: Field of View (from side) KEY: A. Optimal mounting height B. Sensor C. Top of range D. Floor or ground E. Range of the coverage layer (Ultra Short, Short, Intermediate, Long) NOTE: The field of view data are typical for full-body movement when the unit is mounted as specified, but they can be affected by the type and quantity of clothing worn, temperature characteristics, and an object's size and speed Schneider Electric. All Rights Reserved.

9 A2 Square D Clipsal 110 Outdoor PIR Motion Sensor 11/2007 Instruction Bulletin Mounting and Orientation The effective range of the unit will depend on how it is mounted and the operating conditions, such as temperature and the size or speed of an approaching object or person. The unit s field of view will be best when it is mounted in a vertical position at a height of 8 ft (2.4 m) above the ground or floor so that the sensors will have a clear field of view. When selecting a location for the sensor, find an area that is away from objects that can create rapid temperature changes, such as air-conditioning or heating vents or fountains. Any stable flat surface can be used for mounting, including a wall or ceiling. A standard wall box or wall plate can also be used. Orient the lens so that the approach path is across the field of view, not directly toward the sensor (see the optimal approach path in figure Field of View (from top) ). Adjustable Neck Assembly An adjustable neck assembly with ball joints at each pivot point makes it possible to mount the sensor in a vertical or horizontal position. For re-alignment instructions, see the section Positioning and Aligning the Sensor Unit. Network Considerations The 110 Outdoor PIR Motion Sensor can draw 18 ma from the C-Bus network. Determine the total network current load and verify that there will be enough C-Bus power to support all connected devices. Also verify that the amount of available power per C-Bus network is no more than 2A Schneider Electric. All Rights Reserved. 9

10 Square D Clipsal 110 Outdoor PIR Motion Sensor A2 Instruction Bulletin 11/2007 CONFIGURING, LABELING, AND RECORDING THE LOCATIONS OF C-BUS UNITS C-Bus units must be configured, at a minimum, with the unit address and part name before being physically installed on the network. Each unit is identified by a unique serial number found on the box label (see the figure Example of a Box Label with Lift-and-Peel Section ). The serial number provides important information for recording a unit's location. An infrared barcode scanner may be used to read the box label's bar code for the serial number and unit information. Use the C-Bus Toolkit to assign the unit a unique address, and then mark the unit address and part name directly onto the unit before physical installation. You can use the lift-and-peel label from the unit box, or write the unit address and part name directly on the unit. After marking the unit, record each unit's physical location onto a site plan or panel schedule. Figure 4: Example of a Box Label with Lift-and-Peel Section KEY: A. Serial number B. Bar code C. Lift-and-peel section HAZARD OF UNEXPECTED OR UNINTENDED OPERATION Properly configure, label, and record the location of each unit. Retain location records and provide them to the person(s) responsible for configuring and commissioning the network. Failure to follow these instructions can result in unintended C-Bus network operation Schneider Electric. All Rights Reserved.

11 A2 Square D Clipsal 110 Outdoor PIR Motion Sensor 11/2007 Instruction Bulletin Components Needed for Configuration The following components are typically required for unit configuration. PC with the C-Bus Toolkit software installed. Unit to be configured. A PC to C-Bus network communication unit such as a C-Bus PC Interface (SLC5500PC) or C-Bus Ethernet Network Interface (SLC5500CN). Adequate C-Bus power (SLC5500TPS/SLC5500HPS or device power supplies) to support all connected devices. Components Needed for Operation The following components are typically required for operation. (Specific product numbers can vary according to the network.) C-Bus output unit such as a dimmer (SLC5504TD2A) or relay (SLCL5504TRVF) Adequate C-Bus power (SLC5500TPS/SLC5500HPS or device power supplies) to support all connected devices. NOTE: A Powerlink NF3000G3C controller may be used with a PC Interface (SLC5500PC) to configure and operate C-Bus units Schneider Electric. All Rights Reserved. 11

12 Square D Clipsal 110 Outdoor PIR Motion Sensor A2 Instruction Bulletin 11/2007 SAFETY PRECAUTIONS This section contains important safety precautions that must be followed before attempting to install or maintain electrical equipment. Carefully read and follow the safety precautions below. HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH This equipment must be installed and serviced by qualified electrical personnel. Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E. Turn off all electrical power supplying this equipment before working on or inside the equipment. Always use a properly rated voltage sensing device to confirm that power is off. Replace all devices, doors, and covers before turning on power to this equipment. Failure to follow these instructions will result in death or serious injury Schneider Electric. All Rights Reserved.

13 A2 Square D Clipsal 110 Outdoor PIR Motion Sensor 11/2007 Instruction Bulletin INSTALLATION Installing the Sensor Unit Follow the procedures in this section to properly install 110 Outdoor PIR Motion Sensor. The sections below give the most efficient sequence for installing the sensor on a standard plate or wall box. There are four brief steps: applying the weather-resistant rubber seal to the lead, connecting the sensor lead to the included terminal block, mounting the unit, and verifying installation. Before you begin the installation process, verify that the mounting location meets the necessary criteria, such as being 8 ft (2.4 m) or more above the floor so that the sensor s field of view is clear of obstructions (see section Positioning Guidelines ). NOTE: To protect the sensor lens, leave the cardboard lens protector in place until it is time to verify installation. Applying the Weather-resistant Seal The enclosed weather-resistant seal (two plastic fittings with a sealing-washer assembly) is placed on the sensor lead to protect the sensor connections from the weather. The large and small fittings are screwed together over the sealing-washer assembly. The large fitting also threads into the sensor mounting base. Figure 5: Weather-resistant Fitting Assembly KEY: A. Sensor base B. Sensor unit C. Sensor lead D. Small fitting E. Rubber seal F. Large fitting G. Sensor base threaded entry 2007 Schneider Electric. All Rights Reserved. 13

14 Square D Clipsal 110 Outdoor PIR Motion Sensor A2 Instruction Bulletin 11/ Remove and discard the retaining nut on the large fitting. Do not remove the rubber seal washer from the large fitting. 2. Select one of the threaded entries on the base of the sensor unit. Using a large flat-bladed screwdriver loosen and remove and discard the entry cap 3. Insert the large fitting into the threaded entry in the mounting base of sensor unit (refer to figure Components of the 110 Outdoor PIR Motion Sensor ). Do not tighten the fittings fully at this time, as you might need to adjust the cable before the installation has been completed. 4. Slide the rubber seal onto the sensor lead. 5. Slide the small fitting onto the sensor lead, starting from the unthreaded end. 6. Insert the flying lead into the opening in the large fitting. 7. Move the rubber seal and small fitting down toward the large fitting until you can thread the two fittings together. Connection to the C-Bus Network The 110 Outdoor PIR Motion Sensor is connected to the C-Bus network through a C-Bus network cable that uses unshielded twisted pair (UTP) Category 5 data cable. For optimal performance, use the connections recommended below for each end of the cable. Attach the terminal screws to the end of the cable. NOTE: The C-Bus network connection is polarity sensitive. The polarity is marked on the unit beside the terminals. NOTE: Do not solder wired used to connect the unit to the C-Bus through the terminal screws. HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Do not connect line voltage to any C-Bus terminal. Failure to follow this instruction can result in personal injury or equipment or property damage Schneider Electric. All Rights Reserved.

15 A2 Square D Clipsal 110 Outdoor PIR Motion Sensor 11/2007 Instruction Bulletin Figure 6: C-Bus Wiring Connections KEY: A. C-Bus positive (+) B. C-Bus negative ( ) C. Remote OFF: brown + brown-white* D. Remote ON: green + green-white* Table 4: C-Bus Cable Conductor Assignments Terminal C-Bus Network Connection Cable Color Not connected Remote ON* Green-White Not connected Remote ON* Green C-Bus Neg ( ) C-Bus Neg ( ) Orange-White C-Bus Neg ( ) C-Bus Neg ( ) Blue-White C-Bus Pos (+) C-Bus Pos (+) Blue C-Bus Pos (+) C-Bus Pos (+) Orange Not connected Remote OFF* Brown-White Not connected Remote OFF* Brown *Not internally connected. Sensor Wiring Connections The sensor unit s wire lead is inserted into one end of the included terminal block. Use the steps below to make the connection. NOTE: The C-Bus network connection is polarity sensitive, as is shown in the figure Connection to the C-Bus Network. 1. Before you connect the wires of the sensor lead to the terminal block, remove the backing from the gasket and apply it to the mounting area, sticky side down. 2. Attach the included bootlace terminals to the wires of sensor lead. 3. Connect the terminated C-Bus network wires to the other side of the terminal block Schneider Electric. All Rights Reserved. 15

16 Square D Clipsal 110 Outdoor PIR Motion Sensor A2 Instruction Bulletin 11/ Connect the terminated wires of the sensor lead to one side of the terminal block. 5. Verify that the polarity of the connection is correct (see figure Connection to the C-Bus Network ). Figure 7: Wiring Connections to the C-Bus Network KEY: A. Outdoor PIR unit B. Sensor lead connections from sensor unit to C-Bus network: Brown = Negative ( ); White = Positive (+) C. Wiring terminal block D. Connection terminals: Negative ( ): Brown sensor wire E. Connections from C-Bus network F. Connection terminals: Positive (+): White sensor wire Mounting the Sensor Unit The steps below explain the final steps to mount the sensor base. 1. Place the base of the unit against the mounting surface, over the gasket, and thread the screws into the mounting holes until they are fully tightened. 2. Cover the heads of the screws by inserting the screw-hole caps. Megger Testing Guidelines Do not Megger test C-Bus data cabling or terminals. Megger testing of data cabling or terminals can degrade the performance of the C-Bus network. It will not harm the C-Bus units if electrical power terminals only are Megger tested. But because C-Bus units contain electronic components, the Megger readings will not be correct. To obtain valid readings, disconnect the power lines from the C-Bus units Schneider Electric. All Rights Reserved.

17 A2 Square D Clipsal 110 Outdoor PIR Motion Sensor 11/2007 Instruction Bulletin HAZARD OF C-BUS NETWORK PERFORMANCE DEGRADATION Do not Megger test C-Bus data cabling or terminals as it can degrade the performance of the C-Bus network. Failure to follow this instruction will result in damage to the C-Bus network. Positioning and Aligning the Sensor Unit To operate effectively, the PIR Motion Sensor must be positioned and aligned correctly. The effective range will depend on proper mounting as well as extraneous conditions, such as the background temperature, the speed of an approaching object or body, and the types of clothing that are worn. NOTE: Protect the sensor lens from damage by leaving the cardboard lens protector in place on the sensor window until it is time to verify installation. Positioning Guidelines Use the guidelines in this section to determine where to position a unit in its designated area. Position the unit 8 ft (2.4 m) or more above the ground or floor so that the field of view will not be obstructed. Position the unit so that the approach path is across the face of the sensor. Select a stable mounting surface that will not be moved by the wind or other causes. Select an area away from objects that can create rapid temperature changes (e.g., not near air-conditioning vents, heater flues, or sprinklers). Select a location where the unit can be easily accessed. Do not cover the unit Schneider Electric. All Rights Reserved. 17

18 Square D Clipsal 110 Outdoor PIR Motion Sensor A2 Instruction Bulletin 11/2007 Neck Assembly The neck assembly of the PIR Motion Sensor has ball joints at each pivot point, so the sensor head can be placed in almost any position after installation. The sensor unit mounting base can be attached to a standard wall box, wall plate, and flat surfaces such as a wall or ceiling. Refer to the figure Components of the Adjustable Neck Assembly. Figure 8: Components of the Adjustable Neck Assembly KEY: A. Clamping nut B. Ball joint C. Knuckle Range of Motion To re-align the sensor head, loosen the clamping nuts at each ball joint. The curve (knuckle) in the neck assembly must follow the direction in which the sensor is to be directed. If it is difficult to turn the neck assembly or sensor head, loosen the clamp nuts and if necessary, re-align the neck. Never attempt to force the sensor head into position. The sensor unit s range of motion varies with the mounting position (see figures Range of Motion for Wall-Mounted Units and Range of Motion for Ceiling-Mounted Units ). NOTE: The curve of the neck assembly must follow the direction in which the sensor head is to be directed Schneider Electric. All Rights Reserved.

19 A2 Square D Clipsal 110 Outdoor PIR Motion Sensor 11/2007 Instruction Bulletin Wall Mount In the horizontal plane, the sensor head can be positioned +90 from the center. In the vertical plane, the sensor head can be rotated upward 90 and downward 65. Figure 9: Range of Motion for Wall-Mounted Units KEY: A. Top view of rotation in the horizontal plane B. Side view of rotation in the vertical plane Ceiling Mount In the horizontal plane the sensor head can be rotated 360. In the vertical plane, the sensor head can be rotated downward 90. Figure 10: Range of Motion for Ceiling-Mounted Units Changing the Sensor Unit's Alignment Initially the Outdoor PIR Motion Sensor is aligned to mount in a vertical position, such as on a wall. Figures and instructions below show how to re-align the neck assembly so that the unit can be mounted on the ceiling. NOTE: Never attempt to force the sensor head into position Schneider Electric. All Rights Reserved. 19

20 Square D Clipsal 110 Outdoor PIR Motion Sensor A2 Instruction Bulletin 11/2007 Figure 11: Re-Aligning the Motion Sensor for Ceiling Mounting KEY: A. Initial alignment of the PIR Motion Sensor B. Rotating the neck assembly 180 C. Rotating the mounting plate D. Final alignment E. Curve (knuckle) following the direction of the sensor head F. Orientation of the sensor head 1. To adjust the PIR for mounting on the ceiling, loosen the clamping nuts that hold the neck and rotate the neck assembly Rotate the mounting plate 90 (see Figures C and D ). 3. Tighten the clamping nuts. The sensor head will now be in a position suitable for ceiling or overhead mounting. 4. Tighten the large and small weather-resistant cable fittings. Verifying Installation A Walk Test is performed to verify that the sensor has been installed correctly. Part of this procedure requires using the sensoradjustment screw to change the light-level setting. The sections below outline how to use the light-level sensor-adjustment screw and how to perform the walk test. NOTE: Testing a sensor s installation requires connection to the powered ON C-Bus network Schneider Electric. All Rights Reserved.

21 A2 Square D Clipsal 110 Outdoor PIR Motion Sensor 11/2007 Instruction Bulletin Sensor-Adjustment Screw Figure 12: Setting the Sensor-Adjustment Screw KEY: A. " " Highest light-level threshold, light level never goes above it, so load will always turn on for motion (fully counter-clockwise at about 8 o clock) B. "+" Lowest light-level threshold, light level never goes below it, so load is unlikely to turn on with motion (fully counter-clockwise at about 4 o clock) C. Direction to turn the sensor-adjustment screw (counter-clockwise for the Walk Test, clockwise for most settings) The sensor-adjustment screw has a 270 range-of-motion, with stops at approximately 8 o clock and 4 o clock. At 8 o clock the lightlevel threshold is 150 footcandles, at 4 o clock the light-level threshold is 0 footcandles. When the adjustment screw has been turned fully counterclockwise to 8 o clock, the light-level threshold is so high that ambient light levels will always fall below. So long as there is motion, a load will remain on. When the adjustment screw has been turned fully clockwise to 4 o clock, the light-level threshold is so low that ambient light levels will virtually never fall below. Even if motion is detected, it is unlikely that the load will come on. Turning the adjustment screw clockwise from 8 o clock lowers the light-level threshold. When the adjustment screw is set to about 11 o clock, the load will not come on while ambient light-levels are sufficient. When the screw is set to about 1 o clock, the load will be turned on for motion occurring at dusk. When the screw is set to about 3 o clock, the load will be turned on for motion occurring at night Schneider Electric. All Rights Reserved. 21

22 Square D Clipsal 110 Outdoor PIR Motion Sensor A2 Instruction Bulletin 11/2007 Performing the Walk Test NOTE: After connection to the C-Bus network, the unit must be allowed to stabilize for at least two minutes before it is tested. 1. Turn on the power to the unit and let it stabilize for at least two minutes before proceeding. 2. Remove the cardboard lens protector that covers the sensor window. 3. After two minutes, use the sensor-adjustment screwdriver to turn the light-level sensor-adjustment screw fully counter-clockwise until it stops at about 8 o clock (see figure Setting the Sensor- Adjustment Screw ). The adjustment screw rotates 270 be careful not to force the screw beyond its range of travel. 4. Using the C-Bus Toolkit software, set up the sensor unit to control a load and set the PIR time-out interval to one second. 5. If necessary, loosen the clamp nuts on the neck adjustment assembly and aim the sensor head toward the desired field of view. Tighten the clamp nuts and remove the card that protects the lens. 6. Slowly walk around in the desired field of view (around the room, through doorways, etc.) to verify that the load is activated in the correct area. If you encounter problems, loosen the clamp nuts and re-orient the viewing lens. Also refer to the section Troubleshooting Guide. 7. When you have verified that the sensor has been installed correctly, you are ready to finish configuring the sensor unit Schneider Electric. All Rights Reserved.

23 A2 Square D Clipsal 110 Outdoor PIR Motion Sensor 11/2007 Instruction Bulletin Final Configuration Use the C-Bus Toolkit software to re-set the PIR time-out interval to the desired duration. If necessary, you also can make other modifications to the status indicator LED and sensor options, such as the Sunrise/Sunset light-level time delay (see sections Status Indicator and Changing the Light-Level Sensor s Settings ). Status Indicator The SLC5750WPL 110 Outdoor PIR Motion Sensor has a red status indicator LED that turns on when motion has been detected. Other options can be configured by using the C-Bus Toolkit software. Changing the Light-Level Sensor's Settings Below is outlined how the sensor-adjustment screw is used to modify the light-level threshold. Other types of adjustments are made by using the C-Bus Toolkit software. NOTE: The adjustment screw rotates 270 be careful not to force the screw beyond its range of travel. Table 5: Setting the Light-Level Responses Desired Outcome Action Load will turn on during day and night Rotate the screw counter-clockwise until the notch points to approximately 8 o'clock. Load will be off when ambient light is sufficient Rotate the screw clockwise until the notch points to approximately 11 o'clock. Load will turn on at dusk Rotate the screw clockwise until the notch points to approximately 1 o'clock. Load will turn on at night Rotate the screw clockwise until the notch points to approximately 3 o'clock 2007 Schneider Electric. All Rights Reserved. 23

24 Square D Clipsal 110 Outdoor PIR Motion Sensor A2 Instruction Bulletin 11/2007 TROUBLESHOOTING NOTE: Mount the unit away from objects that can cause rapid temperature changes (e.g., not near air-conditioning vents, heater flues, or sprinklers). Table 6: Possible Operating Problems and the Solutions Problem Possible Source of Problem Recommended Solution Light turns on for no apparent reason. Light turns on during daylight Light not on in dim or dark conditions. Light is on permanently. Momentary power outage. Unseen target. Extreme drafts of hot or cold air. Trees or bushes moving in the wind near a heat source, such as a wall or driveway. Vehicles or pedestrians on the edge of the field of view. Wrong sensor-adjustment screw setting. C-Bus installation incorrect. Light bulb is burned out. Wrong sensor-adjustment screw setting. Unit has been installed incorrectly. Moving infrared source is being detected. No action, unit will reset after "time out." Look for animals (e.g., dogs, cats, birds) Look for active air conditioning outlets, heater flues, or fountains. No action, unit will reset after "time out." Adjust the field of view and aiming of sensor so that it does not extend to peripheral areas. Reset according to the section Changing the Light-Level Sensor s Settings. Refer to the installation instructions. Replace light bulb. Reset according to the section Changing the Light-Level Sensor s Settings. Refer to the installation instructions. Mask the viewing window and the light should turn off after the time out. If the light remains on, call the installer Schneider Electric. All Rights Reserved.

25 A2 Square D Clipsal 110 Outdoor PIR Motion Sensor 11/2007 Instruction Bulletin STANDARDS Table 7: U.S. and Canadian Product Safety Standards and U.S. FCC Regulations Standards/Regulations CSA C22.2 No. 205 Title Signal Equipment UL916 Energy Management Equipment FCC Part 15 Part 15, Class B Digital Device for Home or Office Use 2007 Schneider Electric. All Rights Reserved. 25

26 Square D Clipsal 110 Outdoor PIR Motion Sensor A2 Instruction Bulletin 11/2007 SPECIFICATIONS Table 8: Technical Specifications Operating Voltage Range V 18 ma, drawn from the C-Bus network Field of View 110 PIR Detection Field at Max. Sensitivity Typically 3000 ft² (279 m²) Light-Level Inhibit Threshold Continuous from 0.1 footcandle (1 lux) to full sunlight Number of Detection Zones Timer Delay Range Number of Units/Network 18 Long range 16 Intermediate range 10 Short range 4 Ultra-short range O sec to 18 hr (5 sec interval) Use the C-Bus Calculator, a software utility, to determine the total network current load Dimensions 4.5 in. (L) x 2.9 in. (W) x 5.5 in. (D) [114 mm (L) x 74 mm (W) x 140 mm (D)] Weight 8 oz (227 g) Mounting - Standard plate/box with 3.3 in. (94 mm) centers - Surface: Wall or ceiling - Height: 8 ft (2.4 m) above floor with sensor head vertical Operating Environment Outdoors - Temperature: 32 F to +122 F (0 C to +50 C) Note: The SLC5750WPL Outdoor Motion Sensor has no user-serviceable parts Schneider Electric. All Rights Reserved.

27 A2 Square D Clipsal 110 Outdoor PIR Motion Sensor 11/2007 Instruction Bulletin DIMENSIONS Figure 13: Dimensions of the 110 Outdoor PIR Motion Sensor 2007 Schneider Electric. All Rights Reserved. 27

28 Square D Clipsal 110 Outdoor PIR Motion Sensor Instruction Bulletin SUPPORT AND SERVICE Contact the Square D Customer Information Center for technical support by phone at Square D ( ) or at lightingcontrol.support@us.schneider-electric.com. Contact your local Square D service representative or Square D Clipsal certified installer for repairs or service to your network. You may also find helpful information on our web site at Schneider Electric, USA 295 Tech Park Drive La Vergne, TN, SquareD ( ) Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. Square D,, Clipsal,and C-Bus are trademarks or registered trademarks of Schneider Electric and/or its affiliates in the United States and/or other countries Schneider Electric. All Rights Reserved A2 11/2007

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input

More information

Square D Clipsal Two-Channel DIN-Rail DALI Gateway

Square D Clipsal Two-Channel DIN-Rail DALI Gateway Square D Clipsal Two-Channel DIN-Rail DALI Gateway SLC5502DAL for Use with C-Bus Wired Networks Instruction Bulletin Retain for future use. Square D Clipsal Two-Channel DIN-Rail DALI Gateway 63249-420-226A1

More information

Square D Clipsal C-Bus Network Analyzer

Square D Clipsal C-Bus Network Analyzer Square D Clipsal C-Bus Network Analyzer for Use with C-Bus Wired Networks Instruction Bulletin Retain for future use. Square D Clipsal C-Bus Network Analyzer 63249-420-234A1 Instruction Bulletin 12/2006

More information

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management

More information

LED Security Spotlight User Manual

LED Security Spotlight User Manual MOT ION-TR ACKING LED Security Spotlight User Manual www.jascoproducts.com 1-800-654-8483 2 TABLE OF CONTENTS Parts List 3 Questions? Missing Parts? 4 Installation (Wall mount) 6-9 Installation (Eave mount)

More information

Wireless Indoor/ Outdoor Thermometer

Wireless Indoor/ Outdoor Thermometer Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...

More information

LED MOTION ACTIVATED FLOOD LIGHT

LED MOTION ACTIVATED FLOOD LIGHT Utilitech & UT Design are registered trademarks of LF, LLC. All Rights Reserved. ITEM #0611551, #0611550 LED MOTION ACTIVATED FLOOD LIGHT MODEL #SE1036-BP2-02LF0-U, SE1036-WH3-02LF0-U Français p. 10 Español

More information

4.3-inch Back-Up Camera

4.3-inch Back-Up Camera TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION

More information

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system pool/spa control system ScreenLogic Wireless Connection Kit Installation Guide P/N 520663 - Rev B 8 Technical Support Contact Technical Support at: Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800)

More information

LED MOTION ACTIVATED FLOOD LIGHT

LED MOTION ACTIVATED FLOOD LIGHT Utilitech & UT Design are registered trademarks of LF, LLC. All Rights Reserved. ITEM #0460794, 0459228 LED MOTION ACTIVATED FLOOD LIGHT MODEL #SE1019-WH3-02LF0-U, SE1019-TBZ-02LF0-U Français p. 8 Español

More information

Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)

Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R) Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R) This document outlines the specifications for the Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)

More information

LOS 2500 SUPER CEILING SENSOR. Installation Manual

LOS 2500 SUPER CEILING SENSOR. Installation Manual LOS 2500 SUPER CEILING SENSOR Installation Manual How Do RAB Occupancy Sensors Work? Selecting A Location: The L0S2500 sensor sees infrared heat changes caused by the motion of people within its detection

More information

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical

More information

Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC

Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC Please do not return this item to the store. If you have any questions, please contact

More information

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings Features SMART SWITCH OCCUPANCY SENSOR Installation Manual Maximum Energy savings Sensitive 180º view passive infrared motion detector keeps lights on only when rooms are in use. No ON switch so lights

More information

Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location Wireless Alarm System Wireless Keypad User s Manual 1 2 3 4 Choice ALERT Control all sensors, accessories and remote transmitters from one location Table of Contents Important Safeguards 4 Introduction

More information

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location Wireless Alarm System Panic Button User s Manual Choice ALERT Control all sensors, accessories and remote transmitters from one location Table of Contents Important Safeguards 4 Introduction 5 Activating

More information

OC810 Outdoor Camera Setup Guide

OC810 Outdoor Camera Setup Guide OC810 Outdoor Camera Setup Guide P/N: 957YU60001 Document Version: 1.0 Copyright 2010. All Rights Reserved. All trademarks and trade names are the properties of their respective owner i Package Contents

More information

OC810 Outdoor Camera Installation Guide

OC810 Outdoor Camera Installation Guide OC810 Outdoor Camera Installation Guide P/N: 957YU601GJ Document Version: 1.0 Copyright 2011. All Rights Reserved. All trademarks and trade names are the properties of their respective owner i Package

More information

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app. Sense Components Sense monitor Antenna assembly External mounting kit Current sensors Download the Sense app. Go to sense.com/app Power cable Technical Specifications Sense is a home energy monitoring

More information

BeoLab 1. User s guide

BeoLab 1. User s guide BeoLab 1 User s guide Legal notice: CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing

More information

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE MODEL HAA51 PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE OPERATING MANUAL HAA51 PASSIVE INFRARED INTRUDER DETECTOR INTRODUCTION HAA51 Passive Infrared

More information

RC8021 Indoor Camera Installation Guide

RC8021 Indoor Camera Installation Guide RC8021 Indoor Camera Installation Guide P/N: 957YL502GJ Document Version: 1.0 Copyright 2011. All Rights Reserved. All trademarks and trade names are the properties of their respective owners i Package

More information

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS LiteAide HE-100B HE-100BW HE-112 HE-112W HE-117 HE-117W HE-117-2B OWNER'S MANUAL FLOOD LAMPS (BULBS) Your

More information

5W LED Energy Saver PIR Bulkhead

5W LED Energy Saver PIR Bulkhead 5W LED Energy Saver PIR Bulkhead Model: LED88PIR Black I n s t a l l a t i o n & Ope r a t i n g I n s t r u c t i o n s 1. General information: The unit utilises passive infrared technology to detect

More information

=============================== WARNING

=============================== WARNING =============================== WARNING EXPLANATION OF GRAPHICAL SYMBOLS This symbol is intended to alert the user to the presence of unprotected dangerous voltage" within the product's enclosure that

More information

ST815 Illumination Sensor with LCD

ST815 Illumination Sensor with LCD ST815 Illumination Sensor with LCD The Illumination Sensor with LCD (refer to as Illumination Sensor hereafter) is a Z-Wave TM enabled device which is fully compatible with any Z-Wave TM enabled network.

More information

OC821 Iris Outdoor Camera Set-Up Guide. RC8221 Iris. Camera Set-Up Guide

OC821 Iris Outdoor Camera Set-Up Guide. RC8221 Iris. Camera Set-Up Guide Outdoor Camera Set-Up Guide RC8221 Iris Camera Set-Up Guide 2 2 A B Package Contents Basic A. Outdoor Setup Camera This B. chapter Power provides Adapter details on how to setup and mount the camera. C.

More information

Radiant Temperature Sensor TY7321

Radiant Temperature Sensor TY7321 AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional

More information

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN BeoLab 4 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified service

More information

C-Bus. Single Zone Thermostat. 5070THB Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

C-Bus. Single Zone Thermostat. 5070THB Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT C-Bus Single Zone Thermostat 5070THB Series REGISTERED DESIGN REGISTERED PATENT Clipsal is a registered trademark of Clipsal Australia Pty Ltd ABN 27 007 873 529. Copyright Clipsal Australia Pty Ltd 2008.

More information

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location 45131 Wireless Alarm System Window/Door Sensor User s Manual Choice ALERT Control all Sensors & accessories from one location Table of Contents Important Safeguards 4 Introduction 5 Installation 6 Assigning

More information

Mini Power Bank and Charger

Mini Power Bank and Charger Mini Power Bank and Charger Owner s Manual Please read before using this equipment. Your charger is ETL listed to UL standards and meets all applicable FCC standards. WARNING: To reduce the risk of fire

More information

Dual Technology Ceiling Mount Sensor

Dual Technology Ceiling Mount Sensor 369652b 1 05.04.12 Dual Technology Ceiling Mount Sensor The ceiling-mount dual-technology sensors can integrate into Lutron systems or function as stand-alone controls using a Lutron power pack. The technology

More information

NFC Communication Tray Model: HHX-IT3-Z

NFC Communication Tray Model: HHX-IT3-Z INSTRUCTION MANUAL NFC Communication Tray Model: HHX-IT3-Z ENGLISH CONTENTS Introduction...3 Important safety information...4 Know your unit...6 Transferring data to the PC...7 Care and maintenance...8

More information

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal O N DS160/DS161 Installation Guide High Performance Request-to-Exit Sensors 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for Request to Exit (REX) interior applications.

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver. Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver. OWNER'S MANUAL VR36A XC18A XM13A MODEL VK69A (INCLUDES XC18A CAMERA, XM13A

More information

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers! BeoLab 6002 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects

More information

Energy Smart Electric Water Heater Controller

Energy Smart Electric Water Heater Controller Installation, Operation and Troubleshooting Instructions Energy Smart Electric Water Heater Controller Table of Contents Installation and Setup, 2 Operation, 5 Troubleshooting, 7 Regulatory Notices, 11

More information

USB/VGA Cat 5 UTP Console Extender

USB/VGA Cat 5 UTP Console Extender USB/VGA Cat 5 UTP Console Extender SV565UTPU SV565UTPUGB SV565UTPUEU Instruction Manual FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital

More information

EF-S18-55mm f/3.5-5.6 IS II COPY ENG. Instruction

EF-S18-55mm f/3.5-5.6 IS II COPY ENG. Instruction EF-S18-55mm f/3.5-5.6 IS II ENG Instruction Thank you for purchasing a Canon product. The Canon EF-S18-55mm f/3.5-5.6 IS II lens is a high-performance standard zoom lens developed for digital SLRs compatible

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS Before you install or use the apparatus, you must read and understand these Important Safety Instructions. At all times when using the apparatus you must follow these Important

More information

PLL2210W LED LCD Monitor

PLL2210W LED LCD Monitor PLL2210W LED LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Quick Installation...6

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Residential Gateway (RG) Battery Backup REV B

Residential Gateway (RG) Battery Backup REV B Residential Gateway (RG) Battery Backup REV B Save this user manual This manual contains important instructions regarding the installation and operation of this device. Read this manual thoroughly before

More information

Broadband Telecommunications Drop Amplifier

Broadband Telecommunications Drop Amplifier INSTALL SHEET BDA Broadband Telecommunications Drop Amplifier Introduction The Broadband Telecommunications Drop Amplifier (BDA) is a two-way, 1 GHz amplifier designed for customer-premise amplification

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE m Before Use Please read IMPORTANT SAFETY INSTRUCTIONS on page 10 before use. It is important

More information

BIG GAMES HOME VIDEO ARCADE ASSEMBLY INSTRUCTIONS

BIG GAMES HOME VIDEO ARCADE ASSEMBLY INSTRUCTIONS TM BIG GAMES HOME VIDEO ARCADE ASSEMBLY INSTRUCTIONS IN-HOME ASSEMBLY OF YOUR BIGGAMES HOME VIDEO ARCADE MAY BE AVAILABLE IN YOUR AREA FOR AN ADDITIONAL CHARGE. FOR INFORMATION, PLEASE CALL (800) 749-4345.

More information

AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power

AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power VEC173 ONE YEAR LIMITED WARRANTY PROGRAM This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of Vector Manufacturing, regarding this product.

More information

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN BeoLab 7-6 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified

More information

ASSEMBLY &OPERATING INSTRUCTIONS Solar Motion-Activated Security Light - 80 LED Lights Model #40225

ASSEMBLY &OPERATING INSTRUCTIONS Solar Motion-Activated Security Light - 80 LED Lights Model #40225 MOTION-ACTIVATED SECURITY LIGHT ASSEMBLY &OPERATING INSTRUCTIONS Solar Motion-Activated Security Light - 80 LED Lights Model #40225 IMPORTANT: READ ALL INSTRUCTIONS CAREFULLY BEFORE USE ABOUT YOUR SOLAR

More information

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 ENG Instructions Thank you for purchasing a Canon product. Canon s TS-E lenses are tilt-shift lenses designed for EOS cameras. The tilt-shift mechanism enables

More information

FIRERAY 2000 Installation Guide

FIRERAY 2000 Installation Guide FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description

More information

2013 VTech Printed in China 91-009656-000 US

2013 VTech Printed in China 91-009656-000 US Rechargeable Power Pack User s Manual 2013 VTech Printed in China 91-009656-000 US INTRODUCTION The Rechargeable Power Pack makes it easier than ever to keep the InnoTab 3 or InnoTab 3S charged and ready

More information

BeoLab 7-1 BeoLab 7-2. Guide

BeoLab 7-1 BeoLab 7-2. Guide BeoLab 7-1 BeoLab 7-2 Guide CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified service personnel. WARNING: To prevent

More information

EF-S18-135mm f/3.5-5.6 IS

EF-S18-135mm f/3.5-5.6 IS EF-S18-135mm f/3.5-5.6 IS ENG Instruction Thank you for purchasing a Canon product. The Canon EF-S18-135mm f/3.5-5.6 IS lens is a high-performance high-magnification zoom lens equipped with an Image Stabilizer,

More information

Passive Infrared Motion Detector 5420/90. Installation Instructions

Passive Infrared Motion Detector 5420/90. Installation Instructions Passive Infrared Motion Detector Installation Instructions 5420/90 The 5420/90 Passive Infrared Motion Detector provides reliable, high performance detection at an affordable price. The Detector features

More information

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives

More information

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN BeoLab 4000 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified

More information

INSTALLATION GUIDE ConnectLine TV Adapter Getting started

INSTALLATION GUIDE ConnectLine TV Adapter Getting started INSTALLATION GUIDE ConnectLine TV Adapter Getting started PURPOSE OF THIS GUIDE READ THIS FIRST Before your hearing instruments can receive sound from the TV, the adapter must be connected to the TV and

More information

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide 2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620 Quick Installation Guide Table of Contents Verify The Contents Inside Package Box... 3 Physical Installation... 4 Further Configuration...12 Verify

More information

BroadBand PowerShield. User Manual

BroadBand PowerShield. User Manual BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains

More information

AMERBRITE UNDERWATER WHITE LED POOL LAMP

AMERBRITE UNDERWATER WHITE LED POOL LAMP AMERBRITE UNDERWATER WHITE LED POOL LAMP FOR USE ONLY WITH PENTAIR AMERLITE LUMINAIRE INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

More information

TRANSFORMER 1-855-HD-HAMPTON HAMPTONBAY.COM

TRANSFORMER 1-855-HD-HAMPTON HAMPTONBAY.COM Item #1001 509 794 Model DIY-300PS USE AND CARE GUIDE TRANSFORMER Questions, problems, missing parts? Before returning to the store, call HamptonBay Customer Service 8 a.m. - 7 p.m., EST, Monday Friday,

More information

About the HotWire 7900 10-Slot Standalone Shelf

About the HotWire 7900 10-Slot Standalone Shelf TM HotWire Model 7900 10-Slot Standalone Shelf Installation Instructions Document Number 7900-A2-GN10-10 About the HotWire 7900 10-Slot Standalone Shelf The HotWire 7900 10-Slot Standalone Shelf is designed

More information

Transmitter Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso

Transmitter Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso Transmitter Speed 1 9 3 5 0 Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso E L S Tr a n s m i t t e r S p e e d M a n u a l 0 2. 0 2. 2 0 1 0 / / 7

More information

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to

More information

Wireless Alarm System. Silent Alert. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Wireless Alarm System. Silent Alert. User s Manual. Choice ALERT. Control all Sensors & accessories from one location 45137 Wireless Alarm System Silent Alert User s Manual Choice ALERT Control all Sensors & accessories from one location Table of Contents Important Safeguards 4 Introduction 4 Adding a Silent Alert to

More information

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use. BeoLab 11 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects

More information

THE NEW GENERATION IN TECHNOLOGY. NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking. Operating Instructions

THE NEW GENERATION IN TECHNOLOGY. NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking. Operating Instructions THE NEW GENERATION IN TECHNOLOGY NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking Operating Instructions Table of Contents Important Safeguards... 3 Parts... 6 Controls... 6 To Set Up... 7 ipod/iphone

More information

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4 user s manual model #: SPB3200 Charger for Samsung Galaxy S 4 What s Included Unpack the battery case and make sure all accessories are put aside so they will not be lost. hello. USB to Micro USB Cable

More information

Model 53603. Owner s Manual. Español - P. 19 Français - P. 39

Model 53603. Owner s Manual. Español - P. 19 Français - P. 39 Model 53603 Owner s Manual Español - P. 19 Français - P. 39 Table of Contents I. Introduction............................ 1 Sample Watering Plan.......................... 1 II. Installation...........................

More information

GPS AutoSteer System Installation Manual

GPS AutoSteer System Installation Manual GPS AutoSteer System Installation Manual Supported Vehicles John Deere Sprayers 4720 4630 4730 4830 AutoTrac Ready PN: 602-0227-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions in this manual

More information

Power supply unit Model: PAC-SC50KUA

Power supply unit Model: PAC-SC50KUA Building Air Conditioning Control System Power supply unit Model: PAC-SC50KUA Installation Manual Contents 1. Safety precautions... 1 2. Product feature... 2 1. Specification... 2 2. Appearance... 2 3.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

RADIO CONTROLLED DIGITAL CLOCK MODELS 88905 / 88906

RADIO CONTROLLED DIGITAL CLOCK MODELS 88905 / 88906 RADIO CONTROLLED DIGITAL CLOCK MODELS 88905 / 88906 QUICK SETUP GUIDE IMPORTANT! INSTALL BATTERIES IN THE OUTDOOR TRANSMITTER BEFORE INSTALLING BATTERIES IN THE RADIO-CONTROLLED CLOCK. ALKALINE BATTERIES

More information

RF Projection Barometer With Remote Thermo Sensor

RF Projection Barometer With Remote Thermo Sensor RF Projection Barometer With Remote Thermo Sensor Model No.: BAR338P (UK VERSION BAR338PU) User s Manual MAIN UNIT CONTROLS GB INTRODUCTION Congratulations on your purchasing the BAR338P RF Projection

More information

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide BBWX1 Satellite Weather Receiver Installation and Maintenance Guide Rev FUSA 15JUL2007 Table of Contents Safety Precautions 3 Disclaimer. 3 Contents of Package. 4 Tools Required..4 Installation General

More information

Die-Cast Metal, Motion- Activated Post Light

Die-Cast Metal, Motion- Activated Post Light TM Die-Cast Metal, Motion- Activated Post Light Model: SH-9392AU Installation and Operating Instructions FEATURES Automatically comes on when motion is detected. Automatically turns light off. Photocell

More information

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator The Janus Pantheon mini operator does not typically require the provision of any additional site requirements other than

More information

EF24-105mm f/4l IS USM

EF24-105mm f/4l IS USM EF24-105mm f/4l IS USM ENG Instruction Thank you for purchasing a Canon product. The Canon EF24-105mm f/4l IS USM lens is a high-performance standard zoom lens developed for EOS cameras. It is equipped

More information

ES-CAM2A IP Camera. www.etiger.com

ES-CAM2A IP Camera. www.etiger.com ES-CAM2A IP Camera www.etiger.com EN Box content - ES-CAM2A x1 - Mounting bracket x1 - AC Adaptor x1 - User Manual x1 and apps Before using the ES-CAM2A, download the app isecurity+ on the App Store or

More information

Dome Security Camera with IR night vision

Dome Security Camera with IR night vision Dome Security Camera with IR night vision EN INSTRUCTION MANUAL 1 Before you begin Limited Warranty Terms & Conditions Swann Communications warrants this product against defects in workmanship and material

More information

Model 2300DR Installation Guide

Model 2300DR Installation Guide Model 2300DR Installation Guide POWER ACCESS CORPORATION P.O. BOX 1050 170 MAIN STREET NEW HARTFORD, CT 06057 800-344-0088 WEBSITE: www.power-access.com EMAIL: salesinfo@power-access.com 1 STANDARD PARTS

More information

Weather Radio Alarm Clock

Weather Radio Alarm Clock 1200093 User s Guide Weather Radio Alarm Clock Thank you for purchasing your Weather Radio Alarm Clock from RadioShack. Please read this user s guide before installing, setting up, and using your new weather

More information

How To Fix A Cbus Network From A Power Supply To A Power Source

How To Fix A Cbus Network From A Power Supply To A Power Source Online Introductory C-Bus Network Tutorial Square D Clipsal C-Bus Products Training Course Basic Series Online Introductory C-Bus Network Tutorial 1250SM0702A1 Square D Clipsal C-Bus Products Training

More information

DCMT-2500 Wireless Transmitter. Owner s Manual

DCMT-2500 Wireless Transmitter. Owner s Manual DCMT-2500 Wireless Transmitter Owner s Manual Warnings This device complies with Part 15 of the FCC rules, Operation of this device is subject to the following conditions: 1. This device may not cause

More information

2400W PIR LIGHT C O N T R O L L E R Cat No. SLW2400

2400W PIR LIGHT C O N T R O L L E R Cat No. SLW2400 2400W PIR LIGHT C O N T R O L L E R Cat No. SLW2400 1 Introduction The SLW2400 utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the attached lighting

More information

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10 Business Audio System: Music & Messaging MP3 Player by Grace Digital Audio User Guide Model No. GDI-USBM10 User Guide Contents Introduction 2 Safety & General Use Information 2 Features 3 Set Up & Operation

More information

READ FIRST! Universal Car/Air Adapter User Manual

READ FIRST! Universal Car/Air Adapter User Manual AutoAir Manual 1/9/03 2:03 PM Page 1 READ FIRST! Universal Car/Air Adapter User Manual Congratulations! Your new Kensington Universal Car/Air Adapter is a highly efficient Universal Car/Air Adapter for

More information

Point of View Mobii 10 Tegra Tablet. Notice... 2

Point of View Mobii 10 Tegra Tablet. Notice... 2 TABLE OF CONTENTS Notice... 2 1.0 Preface... 2 2.0 Getting to know the basics... 4 3.0 How to Start... 7 3.1 Home Shell... 7 3.1.1 Home Shell > Widgets (Search RSS Weather)... 8 3.1.2 Home Shell > Widgets,

More information

Jarv Joggerz BT-301 Bluetooth Stereo Headphones Users Guide

Jarv Joggerz BT-301 Bluetooth Stereo Headphones Users Guide Jarv Joggerz BT-301 Bluetooth Stereo Headphones Users Guide Features: Bluetooth Wireless technology Compact design fits in the palm of your hand and weighs less than 2 oz. Comfortable Behind the Neck design

More information

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights motion-activated SECURITY LIGHT Model #: 40225, 40226 Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights Important: Read all instructions carefully before use About

More information

Model 70A00-1. GSM Cellular Communications Center

Model 70A00-1. GSM Cellular Communications Center Home Automation, Inc. Model 70A00-1 GSM Cellular Communications Center Operation Manual Document Number 70I00-1 Rev A August, 2009 Contents Description... 1 Use with security systems...1 Everyday use...2

More information

1000-LB. TRAILER JACK OWNER S MANUAL

1000-LB. TRAILER JACK OWNER S MANUAL 1000-LB. TRAILER JACK OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious

More information

Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions

Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions Description The Flame Integrated Sampling System (FLAME-DA-CUV-UV-VIS) is a snap-on, direct-attach 1 cm cuvette

More information

USB-ISS-UV/VIS Integrated Sampling System Installation and Operation Instructions

USB-ISS-UV/VIS Integrated Sampling System Installation and Operation Instructions USB-ISS-UV/VIS Integrated Sampling System Installation and Operation Instructions Description The USB-ISS-UV/VIS Integrated Sampling System is a snap-on, direct-attach 1 cm cuvette holder and UV/VIS/NIR

More information