industrial steel buildings

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "industrial steel buildings"

Transcription

1 industrial steel buildings The industrial roofing and the industrial buildings made of galvanized steel are alwaysdesigned, engineered and manufactured by GIESSE completely according to the customer needs, and always with the highest standards of quality and safety. They are supplied with sliding or fixed sides, and retractable or folding doors. 1 GIESSE - The ideal partner for design and development according to the needs of customer.

2 2

3 EXAMPLES industrial steel buildings 3

4 EXAMPLES industrial steel buildings 4

5 EXAMPLES industrial steel buildings 5

6 MAIN FEATURES Solid structure made of full core metallic profiles (certificated steel Fe 430), which is designed by our engineers according to the values of wind load and snow load of the installation site always respecting the local regulations regarding construction. Surface treatment by hot dip galvanizing, according to the UNI EN ISO 1461 (see next page for details). Completely bolted structure for easy transport, installation and reuse or move on another site. Nuts and bolts class 8.8, galvanized and certified according to UNI. Central and lateral gutters and roof ridges made of galvanized and pre painted steel, thickness 8/10, fastened with rivets and sealants resistant to high temperatures. Downspout in appropriate number in PVC or metal. Covering with panels, thickness and color of your choice (see datasheet at the following pages). Frontispieces and blanks profiles to complete the roof sealing, to prevent the deterioration of the insulating element in the covering panels. Feasibility study, design and certification of the structure and foundation works made by Giesse internal engineering study. Installation performed by our qualified staff, with suitable lifting equipment, in order to ensure the quality of constructions and safety of the people present in the construction site. After assembly will be released: calculation report of the structure prepared by our qualified engineers, certifications of materials, hot dip galvanizing and nuts and bolts used. 6

7 OPTIONAL Perimeter upstand (bardage) with height to define, in corrugated galvanized iron or panels of thickness, type and color of your choice. Skylights on the coverage made in corrugated polycarbonate, thickness 10 mm, with heat welding and rubber pads for perfect sealing. Perimeter walls in corrugated galvanized iron or panels, thickness and color of your choice (see datasheets at the following pages) eventually prepared for windows or doors. Stainless steel flashing, thickness 8/10, joints and rivets, with appropriate sealants specially made for stainless steel and high temperatures resistant. Internal partition walls in panels with predisposition for transit openings. Surface enamel painting, color of your choice or intumescent painting REI 30/60. Coverage and perimeter walls made with GIESSE method: double corrugated galvanized iron (interior and exterior) insulated with glass wool or rock wool inside, thickness of your choice. Roof lifelines. Supply of industrial doors. Emergency exits. Mineral fiber panels for roof and wall insulation REI 30/60/120. THE GALVANIZING PROCESS The structure of industrial buildings GIESSE is always made of hot dip galvanized steel, in compliance with the UNI EN ISO 1461 ( Hot dip galvanized coatings on fabricated iron and steel articles ). Hot dip galvanizing is one of the most popular methods for the protection of steel which in contact with the external environment undergoes inexorable and progressive loss of the typical properties of the metallic state. This protection of steel is obtained by full immersion in a bath of molten zinc at a temperature of 450 C; in this way occurs the creation of a compact layer, called galvanizing, that completely covers the artifact providing a durable protection, very resistant and used in a vast field of applications. The protection occurs with a double mechanism: a barrier effect interposing between the steel surface and the corrosive atmosphere, and a cathodic protection, fretting in case of scratches, nicks or small uncovered areas instead of steel. 7

8 DRAWING DETAILS 8

9 GIESSE SOLUTION (Roof) 9

10 INSULATED PANELS - DELTA (Roof) 10

11 INSULATED PANELS - DELTA (Roof) 11

12 INSULATED PANELS - ALFA (Wall) 12

13 INSULATED PANELS - ALFA (Wall) 13

14 INSULATED PANELS - STAR (Wall) 14

15 INSULATED PANELS - STAR (Wall) 15

16 INSULATED PANELS - Colors INSULATED PANELS - Versions* 16

17 17

18 18

Advantages of Galvanized Steel Gratings

Advantages of Galvanized Steel Gratings Advantages of Galvanized Steel Gratings Galvanization is the process of applying a coating of zinc to steel gratings or other steel structures. Hot dip Galvanization is one such process, in which steel

More information

Composite Panel Firewall Systems

Composite Panel Firewall Systems Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.

More information

- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional

More information

Preformed Metal Roofing and Siding

Preformed Metal Roofing and Siding Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision

More information

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs. Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12

More information

SECTION STANDING SEAM METAL ROOFING

SECTION STANDING SEAM METAL ROOFING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 41 13 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Use for roofing sloped 1 in 4 (3 in/ft) or greater. 3. Delete between // // if not applicable

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

ABSeam Panel Overview and Installation Instructions

ABSeam Panel Overview and Installation Instructions 82 Garden Spot Road Ephrata, PA 17522 717-445-6885 35 Ridge Road Newville, PA 17241 717-776-5951 ABSeam Panel Overview and Installation Instructions Applications: The ABSeam panel is an architectural panel

More information

STANDARD MATERIAL SPECIFICATIONS FOR OUR PREFAB BALI HOUSES

STANDARD MATERIAL SPECIFICATIONS FOR OUR PREFAB BALI HOUSES STANDARD MATERIAL SPECIFICATIONS FOR OUR PREFAB BALI HOUSES We offer four main prefab building material options, viz. a Basic, a Standard, a DeLuxe and a, each of them fitted to your budget or requirements.

More information

C O N T A I N E R. Converted ISO Container

C O N T A I N E R. Converted ISO Container C O N T A I N E R Converted ISO Container TECHNICAL FEATURES Interior wall Assembly CONVERTED I S O CONTAINER Surface treatment/ Painting Below outside: bitumen will be applied Outside: blasting to 2 ½

More information

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems Dow Corning A Thermal Modelling Comparison of Typical Curtain Wall Systems Introduction Today s Aim To understand the meaning of a U value and window energy ratings Discuss the drivers for energy efficiency

More information

Company DUOL. Dušan Olaj CEO

Company DUOL. Dušan Olaj CEO Company DUOL Company DUOL has been active on the market since 1992 and throughout this period Duol has successfully attained the position of one of the most significant suppliers of fabric structures.

More information

LOW COST PREFABRICATED CONSTRUCTION SYSTEM

LOW COST PREFABRICATED CONSTRUCTION SYSTEM LOW COST PREFABRICATED CONSTRUCTION SYSTEM SANDWICH PANEL 100mm [SHEET STEEL + EPS + SHEET STEEL] PREFABRICATED BULDINGS TECHNICAL SPECIFICATIONS 1 GENERAL SYSTEM DESCRIPTION SYSTEM DESCRIPTION: In accordance

More information

INDUSTRIAL ROOFING CASE STUDY: The Advantages of Aluminized Stainless Steel. Roof Installed:

INDUSTRIAL ROOFING CASE STUDY: The Advantages of Aluminized Stainless Steel. Roof Installed: INDUSTRIAL ROOFING CASE STUDY: Aluminized Type 409 and Aluminized Type 439 Roofing Panels were Installed in an Industrial Building Site in Place of Painted GALVALUME. Aluminized Type 2 Carbon Steel was

More information

Tools required by installer: Materials required by installer:

Tools required by installer: Materials required by installer: Installation Guidelines For Quaker Window Products Vinyl replacement product line (Single Hung, Double Hung, Sliding Window, Fixed Window, Casement, Awning, and Hopper) Installer: Read these instructions

More information

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.

More information

Call for a FREE quote ENCORE STEEL BUILDINGS

Call for a FREE quote ENCORE STEEL BUILDINGS Call for a FREE quote 866-614-9153 ENCORE STEEL BUILDINGS 2 Who We Are Who We Are. is a trusted nationwide provider of metal buildings and components. We sell buildings designed for YOU using some of the

More information

September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 September 3, 2009 Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 RE: Ketchikan Gateway Borough Gateway Recreation Center Roof Observations and Intrusive Inspections

More information

Table of Contents PART 1 WINDOW SELECTION GUIDE. Window and Door Selection Guide

Table of Contents PART 1 WINDOW SELECTION GUIDE. Window and Door Selection Guide VOLUME 1 - WINDOWS AND DOORS Window and Door Selection Guide PART 1 WINDOW SELECTION GUIDE WSG-11 PART 2 - PERFORMANCE SPECIFICATIONS Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

Cable Trays Technical Instructions & Specifications

Cable Trays Technical Instructions & Specifications Cable Trays Technical Instructions & Specifications Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased

More information

TARIFF CODE and updates standard

TARIFF CODE and updates standard TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of

More information

SL30-ISO PROFILE SYSTEM

SL30-ISO PROFILE SYSTEM AESTHETICS AND sustainability SL30-ISO PROFILE SYSTEM TECHNICAL DOCuMENTATION WWW.MHB.NL SL30-ISO PROFILE SYSTEM 1. SL30-ISO and SL30-ISO-PLUS Sustainability is getting worldwide more and more the attention

More information

All Weather Hall. Efficient, multipurpose & quick to build

All Weather Hall. Efficient, multipurpose & quick to build All Weather Hall Efficient, multipurpose & quick to build ALL WEATHER HALL www.deboer.com www.deboer.com ALL WEATHER HALL A flexible solution for a multitude of needs All Weather halls from De Boer provide

More information

Armanet BEKAERT. Armanet THE CONSTRUCTIVE IDEA. Render & plaster reinforcing mesh @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@

Armanet BEKAERT. Armanet THE CONSTRUCTIVE IDEA. Render & plaster reinforcing mesh @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ BEKAERT Armanet THE CONSTRUCTIVE IDEA Armanet Render & plaster reinforcing mesh Armanet Renovation Product specification Insulation Reinforcing Mesh Armanet is a heavily galvanized welded mesh used for

More information

EXPERTISE and SOLUTIONS

EXPERTISE and SOLUTIONS STEEL BUILDINGS EXPERTISE and SOLUTIONS Leader in the design and manufacturing of steel buildings, HONCO has acquired extensive expertise and know-how since its founding in 1974. This vast experience has

More information

Viking Sealant PT304 Code STP860 Viking Fastening Bar SDF110. 300mm Viking Polyiso Insulation sheet. Viking WarmSpan Exposed Wall Termination VWS01

Viking Sealant PT304 Code STP860 Viking Fastening Bar SDF110. 300mm Viking Polyiso Insulation sheet. Viking WarmSpan Exposed Wall Termination VWS01 Water Cut off Mastic Viking STP870 Viking Sealant PT304 Code STP860 Viking Fastening Bar SDF110 Fire test ISO9075 'Z' 'Z' = Variable according to wind zoning. Please refer to table 7 E2/AS1 300mm 2 Alternative

More information

Project Name: Reference: Specifier: Date:

Project Name: Reference: Specifier: Date: KALZIP NBS FORMAT (H31) OUTLINE SPECIFICATION Acoustic Purlin Roof Construction 0.20 w/m 2 K U-Value Project Name: Reference: Specifier: Date: H31 METAL PROFILED/FLAT SHEET CLADDING/COVERING To be read

More information

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

TABLE OF CONTENTS SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7 2 TABLE OF CONTENTS SECTION 1: What is a Standing Seam Metal Roof PAGE 3 SECTION 2: Common Types of Standing Seam Metal Roofs..PAGE 5 SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE

More information

ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS

ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS ~GSM SHELTER CONTAINERS ARE PROCUDED ACCORDING TO THE DEMANDED SIZE.~ (W x L x H) Page1 GENERAL FEAUTURES Environmental Conditions : Maximum outdoor temperature

More information

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings BUILDING ENVELOPE DESIGN BY ROXUL Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB Exterior

More information

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Flat Stick Panel System - 4mm thick

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Flat Stick Panel System - 4mm thick 1. SCOPE OF WORK The scope of work includes the design, supply fabrication and installation of Alucobond PLUS aluminium composite panel cladding, complete with all necessary sub-structures, anchors, hardware

More information

Building Owners Guide to a Duro-Last System!

Building Owners Guide to a Duro-Last System! Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof

More information

SECTION 07 61 13 STANDING SEAM METAL ROOFING

SECTION 07 61 13 STANDING SEAM METAL ROOFING SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced

More information

THULE PROFESSIONAL. The professional load carrier system for you and your work van.

THULE PROFESSIONAL. The professional load carrier system for you and your work van. The professional load carrier system for you and your work van. The rugged time-saver. Your job is full of challenges. Transporting the things you need to get the job done no longer has to be one of them.

More information

NC-S 120 STH SLIM. Sliding windows and doors

NC-S 120 STH SLIM. Sliding windows and doors www.metrawindows.it NC-S 20 STH SLIM METRA. THE ONLY COMPANY TO OFFER A COMPLETE RANGE OF PRODUCTS OUR SERVICE ALWAYS CLOSER TO CUSTOMERS METRA s toll free number is always available in order to support

More information

Ver. 2. Guide to. Inspecting Residential Brick Veneer

Ver. 2. Guide to. Inspecting Residential Brick Veneer Ver. 2 Guide to Inspecting Residential Brick Veneer 1. A guide created by industry professionals. The knowledgeable staff at MASONPRO together with technical support from the Masonry Institute of Michigan

More information

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Specifications Preformed Metal Wall and Roof Panels Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Section 07410 Preformed Metal Wall and Roof Panels Structural

More information

SECTION 073113 ASPHALT SHINGLES

SECTION 073113 ASPHALT SHINGLES 1320 / Talent Community Center 073113-1 ASPHALT SHINGLES PART 1 GENERAL 1.01 SECTION INCLUDES A. Asphalt shingle roofing. B. SBS roof membrane. SECTION 073113 ASPHALT SHINGLES C. Flexible sheet membranes

More information

Table of Contents. I. Roof Scuttles

Table of Contents. I. Roof Scuttles Table of Contents I. 1. Specification Guidelines 2. Bilco Quote/Order Checklist 3. Target Markets 4. Product Training 5. Benefits/Features 6. Scuttle Handrails Specification Guidelines Key Bilco features

More information

5621, 5621F Sliding Doors

5621, 5621F Sliding Doors 5621, 5621F Sliding Doors 5621, 5621F SLIDING DRS - 2, 3, 4 - panel - Special size doors available* - - fixed panel - Keyed lock available (Schlage -compatible) 2-panel 2-panel 2-PANEL - Min 5 0 6 8 Max

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

March 14, 2007. Installation of Bay, Bow and Garden Windows

March 14, 2007. Installation of Bay, Bow and Garden Windows March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed

More information

CHANNEL LETTERING INDOOR & OUTDOOR TRADE SHOW DISPLAYS CONSTRUCTION SIGNAGE VEHICLE GRAPHICS REAL ESTATE / DISPLAYS WINDOW GRAPHICS POSTERS

CHANNEL LETTERING INDOOR & OUTDOOR TRADE SHOW DISPLAYS CONSTRUCTION SIGNAGE VEHICLE GRAPHICS REAL ESTATE / DISPLAYS WINDOW GRAPHICS POSTERS CHANNEL LETTERING INDOOR & OUTDOOR SIGNAGE TRADE SHOW DISPLAYS CONSTRUCTION SIGNAGE VEHICLE GRAPHICS REAL ESTATE / DISPLAYS WINDOW GRAPHICS POSTERS info@muizgraphics.com www.muizgraphics.com Tel: 905-362-0268

More information

DETAILED SCOPE OF WORK FOR THE NETCONG ELEMENTARY SCHOOL. The Netcong Board of Education Netcong, Morris County New Jersey. Roof Replacement Project

DETAILED SCOPE OF WORK FOR THE NETCONG ELEMENTARY SCHOOL. The Netcong Board of Education Netcong, Morris County New Jersey. Roof Replacement Project DETAILED SCOPE OF WORK FOR THE NETCONG ELEMENTARY SCHOOL The Netcong Board of Education Netcong, Morris County New Jersey Roof Replacement Project Health and Safety Renovation Projects Roof Replacement

More information

Roof Curbs, Extensions and Equipment Supports

Roof Curbs, Extensions and Equipment Supports Roof s, Extensions and Equipment Supports December 2012 Roof Page s, Header Extensions and Equipment Supports Table of Contents Model GPI Standard and Optional Construction Features... 3 Model Number Code....

More information

The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.

The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc. 26 D+D MARCH 2015 Building Envelope Roland Serino, P.E., Dryvit Systems Inc. here has always been a need for a more efficient way to build in large cities like Chicago, New York, Los Angeles or other central

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining

More information

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers.. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3

More information

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design Basis of Design This section applies to roofing membranes, flashing and accessories. Design Criteria Adhere to the standards and details of the latest editions of the National Contractors Association (NRCA)

More information

Lindab Seamline Application guide. Lindab Seamline TM. Lindab Standing Seam Roofing Application guide

Lindab Seamline Application guide. Lindab Seamline TM. Lindab Standing Seam Roofing Application guide Lindab Seamline Application guide Lindab Seamline TM Lindab Standing Seam Roofing Application guide This handbook deals with long strip roofing with HB Polyester and aluminiumzinc on a boarded roof covering.

More information

protea low cost, high quality housing - Low cost / High quality housing - Insulated structure - Fast and easy installation

protea low cost, high quality housing - Low cost / High quality housing - Insulated structure - Fast and easy installation protea low cost, high quality housing - Low cost / High quality housing - Insulated structure - Fast and easy installation PROTEA Affordable quality housing PROTEA is a modular construction system. Standardised

More information

10. LIGHT-GAUGE STEEL FRAMING

10. LIGHT-GAUGE STEEL FRAMING COLLEGE OF ARCHITECTURE AND PLANNING Department of Architecture and Building Sciences ARCH 436 Contemporary Building Construction Methods 10. LIGHT-GAUGE STEEL FRAMING Dr. Mohammed Ghonim Lecture Objectives

More information

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings Building Envelope Design using ROXUL Building Envelope Design using ROXUL (BEDR ) FIREWALL and ROXUL PLUS MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB

More information

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system

More information

CHAPTER 7: Building Systems ROOFING SYSTEMS

CHAPTER 7: Building Systems ROOFING SYSTEMS ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen

More information

Access Panels By Ductmate

Access Panels By Ductmate Ductware Access Panels By Ductmate Sandwich Access Panels Quick and Easy Advanced Pressure Vessel Design Insulated, Uninsulated, and Specialty Metals No measuring necessary (self-adhesive template provided)

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09 TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09 PMT GUIDE # 10 Book of Order Section G-10.0102o: "The session is responsible for the mission and government of the particular church. It

More information

metal Duil~ing manufacturers Association

metal Duil~ing manufacturers Association metal Duil~ing manufacturers Association ApplicatiDns metal Building Systems Conventional Buildings Retrofit Roofing Projects l~e Perfect Cover.One of the most important technological advances in building

More information

Mark Cramer Inspection Services, Inc.

Mark Cramer Inspection Services, Inc. Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction

More information

Mechanical arms, belts and sheets

Mechanical arms, belts and sheets Car parks Mechanical arms, belts and sheets DETAIL ARM CAR PARK (mm) 5000 Platen 100x5mm Iron sheets 4mm 5000 485 2100 Belts type C 120x50x2 mm 4915 5400 Hot dipped galvanized UNE-EN ISO 1461 or black

More information

Prefabricated building PVC vertical sliding window

Prefabricated building PVC vertical sliding window Prefabricated building PVC vertical sliding window SLOVENSKO ITALIA ESPAÑA ITALIA The company, we have the pleasure to introduce in this brochure, is an important and dynamic industrial company located

More information

Sliding & Stacker Doors. Double-Glazing

Sliding & Stacker Doors. Double-Glazing Windows Bi-Fold Doors Sliding & Stacker Doors Double-Glazing Security Doors Shower Screens Seek Quality CONTENTS 1-2 Windows 3 Bi-fold Doors 4 Sliding & Stacker Doors 5 French Doors 6 Double-Glazing 7

More information

GUIDELINE SPECIFICATIONS

GUIDELINE SPECIFICATIONS GUIDELINE SPECIFICATIONS GORDON SOFFIT-SHIELD - An Exterior Metal Soffit System DIVISION 05 5800 or DIVISION 07 7700 Note To Specifier: SOFFIT-SHIELD should be installed by tradesmen that are experienced

More information

Master Panel 1000 R5 Roof

Master Panel 1000 R5 Roof Master Panel 1000 R5 Roof Product Description The important feature of the roof elements are the easy installation procedure. The element fix exactly and pushed together without much force. Roof coverage

More information

ROOFS - Guidance for Repair, Maintenance and Replacement

ROOFS - Guidance for Repair, Maintenance and Replacement ROOFS - Guidance for Repair, Maintenance and Replacement Guilford Association Architectural Committee ROOFING Slate and tile roofs are a critical design feature of Guilford homes. The homes were designed

More information

Anodes and Misc Equipment

Anodes and Misc Equipment Anodes and Misc Equipment Application: Platinised Titanium Anodes Platinised titanium anodes are recommended for use in the following electrolytic processes:- Precious metal electroplating - e.g. Au, Pt,

More information

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF... Building Insulations - Walls and Ceilings (FM Approval Numbers 4411, 4651, 4880, 4881, 4882) Insulating materials may occur in building construction to reduce heat or sound transmission through a wall,

More information

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings INSULATION FOR PRE-ENGINEERED METAL BUILDINGS ROXUL SAFE 55 & 65 and ROXUL PLUS MB Insulation for Pre-Engineered Metal Buildings ROXUL SAFE AND ROXUL PLUS MB Exterior Wall Insulation for Pre-Engineered

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

SECTION 02832 CHAIN LINK FENCE AND GATES

SECTION 02832 CHAIN LINK FENCE AND GATES SECTION 02832 CHAIN LINK FENCE AND GATES PART 1 GENERAL 1.01 SECTION INCLUDES A. Fabrication, furnishing and installation of chain link fence, chain link gates, and extension brackets with barbed wire.

More information

Fire Resistant Systems

Fire Resistant Systems Fire Resistant Systems A R C H I T E C T U R A L A L U M I N I U M G L A Z I N G S Y S T E M S Fire Resistant Systems Introduction Kawneer are pleased to introduce two new comprehensive Fire Resistant

More information

Building Systems in Aluminium

Building Systems in Aluminium Building Systems in Aluminium 2 Building Systems in Aluminium Sonera, Helsinki, Finland Complete solution Purso building systems The building systems of Purso Oy provide complete solutions for the most

More information

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW Insulated Roof & Wall Panels Trapezoidal Insulated Roof Panels KS1000 RW Overview Kingspan roof panel systems present a superior system compared to conventional multi-part site assembled systems. They

More information

CONDENSATION IN REFRIDGERATED BUILDINGS

CONDENSATION IN REFRIDGERATED BUILDINGS CONDENSATION IN REFRIDGERATED BUILDINGS By: Steve Salisbury Nov. 10, 2010 (revised Nov. 14, 2013) Introduction The following discussion reviews the basic causes of condensation in refrigerated buildings

More information

PVC in automotive. Examining the trends and drivers behind the growth of PVC for dashboard applications

PVC in automotive. Examining the trends and drivers behind the growth of PVC for dashboard applications PVC in automotive Examining the trends and drivers behind the growth of PVC for dashboard applications Summary Introduction The evolution of PVC-slush: past & present How PVC meets the increasingly stringent

More information

2.3. Continuous Hot-Dip Galvanizing versus General (Batch) Galvanizing Rev 1.0 Jan 2011. GalvInfoNote. Introduction. Continuous Galvanizing

2.3. Continuous Hot-Dip Galvanizing versus General (Batch) Galvanizing Rev 1.0 Jan 2011. GalvInfoNote. Introduction. Continuous Galvanizing 2. Coating Processes and Surface Treatments GalvInfoNote 2.3 Introduction Continuous Hot-Dip Galvanizing versus General (Batch) Galvanizing There are two different processes for applying a zinc coating

More information

PGB Architectural Services LTD

PGB Architectural Services LTD Conc Tiles Brickwork Stonework Front Elevation 0 1 4 5 m Side Elevation Cill-950 Win-11065 Cill-485 Win-1655 Conc Tiles Cill-1010 Win-1005 Bath Lounge 2450 Brickwork Head-2040 Hall Ridge Rear Elevation

More information

Since 1978. HMT Inc. 24 Waterway Avenue, Suite 400 The Woodlands, Texas 77380 Ph: +1.281.681.7000 Fax: +1.281.419.7689

Since 1978. HMT Inc. 24 Waterway Avenue, Suite 400 The Woodlands, Texas 77380 Ph: +1.281.681.7000 Fax: +1.281.419.7689 WaTER & wastewater HMT Inc. 24 Waterway Avenue, Suite 400 The Woodlands, Texas 77380 Ph: +1.281.681.7000 Fax: +1.281.419.7689 Locations worldwide to service all your needs. VAPORVAULT and ALUMINATOR are

More information

Ubiflex. Non-lead flashing system

Ubiflex. Non-lead flashing system Ubiflex Non-lead flashing system Ubiflex non-lead flashing Ubiflex is a non-lead waterproof flashing material which can be used in most applications where lead is traditionally used to provide a weatherproof

More information

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Final inspections are completed by site visit only. Access to fenced yards shall be planned. ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,

More information

Hardware Fitting Accessories Information

Hardware Fitting Accessories Information Information Door seals Areas of application Protection against cold, draught and vermin Reduces light leakage Sound insulation Smoke control Fire resistance Reduces the energy consumption of air conditioning

More information

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE RESIDENTIAL MASONRY A BEST PRACTICES GUIDE Build With Brick Build With Boral CONTENTS BRICK :01 MASONRY CEMENT :03 MASONRY SAND :04 WALL TIES :05 STEEL LINTELS :07 DRAINAGE WALL SYSTEM :09 FLASHING :11

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Removable Insulation Blankets from A to Z

Removable Insulation Blankets from A to Z Removable Insulation Blankets from A to Z At first glance, making up a removable insulation blanket seems somewhat simple take some insulation, put some mesh on one side, a cover on the other, sew them

More information

Light Architecture. Colors Sweden. Light

Light Architecture. Colors Sweden. Light Light Architecture Danpalon is the complete daylighting solution offering exceptional quality of light, thermal insulation and UV protection with a rich non-industrial visual appeal. The Danpalon system

More information

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals

More information

Confort 26. Sliding Systems. Sapa Building System

Confort 26. Sliding Systems. Sapa Building System Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are

More information

Automotive Engineered Attachment Systems

Automotive Engineered Attachment Systems Automotive Engineered Attachment Systems (TR-12721) Technical Data Sheet Acrylic Foam RT8000 Series General Information : The acrylic Foam RT8000 Series, which is made by a special process, has a superior

More information

TIGER Drylac U.S.A., Inc. 3855 Swenson Avenue St Charles, IL T 800 243 8148 F 877 926 8148 office.us@tiger-coatings.us www.tiger-coatings.

TIGER Drylac U.S.A., Inc. 3855 Swenson Avenue St Charles, IL T 800 243 8148 F 877 926 8148 office.us@tiger-coatings.us www.tiger-coatings. Product Data Sheet SERIES 69 - DRYZINC ZINC-RICH PRIMER (69/90500) Epoxy zinc-rich powder coating primer. Part of a two-coat TIGER Shield system. Designed to impart superior corrosion protection to steel

More information

Dr. Ali Abadi Chapter 5: Chemical Effect Materials Properties. What is corrosion?

Dr. Ali Abadi Chapter 5: Chemical Effect Materials Properties. What is corrosion? Dr. Ali Abadi Chapter 5: Chemical Effect Materials Properties (Corrosion) Introduction 1 By the end of this tutorial, you should have an understanding of: relative susceptibility of different metals to

More information

Metal Building Systems Installation and Flashings & Details Guide. Table of Contents

Metal Building Systems Installation and Flashings & Details Guide. Table of Contents Table of Contents Section Page Notes to Designer/User..................1-2 Map of Typical Roof Conditions............3 Fastener Placement.......................4 Fastener Selection........................5

More information

Ruukki Finnera. The most intelligent roof ever seen.

Ruukki Finnera. The most intelligent roof ever seen. Ruukki Finnera The most intelligent roof ever seen. Finnera s new and innovative design makes your steel roof not only beautiful but also extremely durable and practical. The revolutionary front-edge folding

More information

Dissimilar Metal Corrosion

Dissimilar Metal Corrosion PDHonline Course S118 (1 PDH) Dissimilar Metal Corrosion Instructor: D. Matthew Stuart, P.E., S.E., F.ASCE, F.SEI, SECB, MgtEng 2013 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658

More information

BIS Metal Pipe Clamps with Lining

BIS Metal Pipe Clamps with Lining A BIS Metal Pipe Clamps with Lining BIS Clamps BISMAT Flash BISMAT 2000 Ø ¼ - 2" BISMAT 2000 Ø 2½ - 4" 2 3 4 BIS Industrial Clamps BIS Heavy Duty Clamps HD1501 (1/2") (BUP1000) 5 BIS Clamps for Plastic

More information

Bunk Slicks. Bolts directly onto carpeted bunk boards. Fits 2 x 6 or 2 x 4 standard bunk boards. Slide on or off with less effort. Easy to Install.

Bunk Slicks. Bolts directly onto carpeted bunk boards. Fits 2 x 6 or 2 x 4 standard bunk boards. Slide on or off with less effort. Easy to Install. Bunk Board Guide On s 24 Part #86123 The 2x4 bunk boards are carpeted. Bunk placement if mounted above frame is 19. Outside of the frame there is 5-11 of side movement. U-bolts and nuts are zinc plated.

More information

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS 08 50 00 WINDOWS

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS 08 50 00 WINDOWS SECTION INCLUDES Metal Windows Vinyl/Aluminum Clad Wood Windows Solid Fiberglass and Vinyl Windows Wood Windows (Historic Preservation only) RELATED SECTIONS 02 83 00 Lead Paint Remediation 06 10 00 Rough

More information

Low-slope reroofing guidelines

Low-slope reroofing guidelines Low-slope reroofing guidelines by Thomas Bollnow and Joan P. Crowe, AIA The NRCA Roofing and Waterproofing Manual, Fifth Edition, contains reroofing guidelines for steep- and low-slope roofing. The August

More information