industrial steel buildings
|
|
- Evelyn Barnett
- 7 years ago
- Views:
Transcription
1 industrial steel buildings The industrial roofing and the industrial buildings made of galvanized steel are alwaysdesigned, engineered and manufactured by GIESSE completely according to the customer needs, and always with the highest standards of quality and safety. They are supplied with sliding or fixed sides, and retractable or folding doors. 1 GIESSE - The ideal partner for design and development according to the needs of customer.
2 2
3 EXAMPLES industrial steel buildings 3
4 EXAMPLES industrial steel buildings 4
5 EXAMPLES industrial steel buildings 5
6 MAIN FEATURES Solid structure made of full core metallic profiles (certificated steel Fe 430), which is designed by our engineers according to the values of wind load and snow load of the installation site always respecting the local regulations regarding construction. Surface treatment by hot dip galvanizing, according to the UNI EN ISO 1461 (see next page for details). Completely bolted structure for easy transport, installation and reuse or move on another site. Nuts and bolts class 8.8, galvanized and certified according to UNI. Central and lateral gutters and roof ridges made of galvanized and pre painted steel, thickness 8/10, fastened with rivets and sealants resistant to high temperatures. Downspout in appropriate number in PVC or metal. Covering with panels, thickness and color of your choice (see datasheet at the following pages). Frontispieces and blanks profiles to complete the roof sealing, to prevent the deterioration of the insulating element in the covering panels. Feasibility study, design and certification of the structure and foundation works made by Giesse internal engineering study. Installation performed by our qualified staff, with suitable lifting equipment, in order to ensure the quality of constructions and safety of the people present in the construction site. After assembly will be released: calculation report of the structure prepared by our qualified engineers, certifications of materials, hot dip galvanizing and nuts and bolts used. 6
7 OPTIONAL Perimeter upstand (bardage) with height to define, in corrugated galvanized iron or panels of thickness, type and color of your choice. Skylights on the coverage made in corrugated polycarbonate, thickness 10 mm, with heat welding and rubber pads for perfect sealing. Perimeter walls in corrugated galvanized iron or panels, thickness and color of your choice (see datasheets at the following pages) eventually prepared for windows or doors. Stainless steel flashing, thickness 8/10, joints and rivets, with appropriate sealants specially made for stainless steel and high temperatures resistant. Internal partition walls in panels with predisposition for transit openings. Surface enamel painting, color of your choice or intumescent painting REI 30/60. Coverage and perimeter walls made with GIESSE method: double corrugated galvanized iron (interior and exterior) insulated with glass wool or rock wool inside, thickness of your choice. Roof lifelines. Supply of industrial doors. Emergency exits. Mineral fiber panels for roof and wall insulation REI 30/60/120. THE GALVANIZING PROCESS The structure of industrial buildings GIESSE is always made of hot dip galvanized steel, in compliance with the UNI EN ISO 1461 ( Hot dip galvanized coatings on fabricated iron and steel articles ). Hot dip galvanizing is one of the most popular methods for the protection of steel which in contact with the external environment undergoes inexorable and progressive loss of the typical properties of the metallic state. This protection of steel is obtained by full immersion in a bath of molten zinc at a temperature of 450 C; in this way occurs the creation of a compact layer, called galvanizing, that completely covers the artifact providing a durable protection, very resistant and used in a vast field of applications. The protection occurs with a double mechanism: a barrier effect interposing between the steel surface and the corrosive atmosphere, and a cathodic protection, fretting in case of scratches, nicks or small uncovered areas instead of steel. 7
8 DRAWING DETAILS 8
9 GIESSE SOLUTION (Roof) 9
10 INSULATED PANELS - DELTA (Roof) 10
11 INSULATED PANELS - DELTA (Roof) 11
12 INSULATED PANELS - ALFA (Wall) 12
13 INSULATED PANELS - ALFA (Wall) 13
14 INSULATED PANELS - STAR (Wall) 14
15 INSULATED PANELS - STAR (Wall) 15
16 INSULATED PANELS - Colors INSULATED PANELS - Versions* 16
17 17
18 18
Composite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
More information- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner
The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional
More informationfoot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.
Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12
More informationPreformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationABSeam Panel Overview and Installation Instructions
82 Garden Spot Road Ephrata, PA 17522 717-445-6885 35 Ridge Road Newville, PA 17241 717-776-5951 ABSeam Panel Overview and Installation Instructions Applications: The ABSeam panel is an architectural panel
More informationSTANDARD MATERIAL SPECIFICATIONS FOR OUR PREFAB BALI HOUSES
STANDARD MATERIAL SPECIFICATIONS FOR OUR PREFAB BALI HOUSES We offer four main prefab building material options, viz. a Basic, a Standard, a DeLuxe and a, each of them fitted to your budget or requirements.
More informationDow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems
Dow Corning A Thermal Modelling Comparison of Typical Curtain Wall Systems Introduction Today s Aim To understand the meaning of a U value and window energy ratings Discuss the drivers for energy efficiency
More informationCompany DUOL. Dušan Olaj CEO
Company DUOL Company DUOL has been active on the market since 1992 and throughout this period Duol has successfully attained the position of one of the most significant suppliers of fabric structures.
More informationINDUSTRIAL ROOFING CASE STUDY: The Advantages of Aluminized Stainless Steel. Roof Installed:
INDUSTRIAL ROOFING CASE STUDY: Aluminized Type 409 and Aluminized Type 439 Roofing Panels were Installed in an Industrial Building Site in Place of Painted GALVALUME. Aluminized Type 2 Carbon Steel was
More informationSTAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
More informationCable Trays Technical Instructions & Specifications
Cable Trays Technical Instructions & Specifications Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased
More informationLOW COST PREFABRICATED CONSTRUCTION SYSTEM
LOW COST PREFABRICATED CONSTRUCTION SYSTEM SANDWICH PANEL 100mm [SHEET STEEL + EPS + SHEET STEEL] PREFABRICATED BULDINGS TECHNICAL SPECIFICATIONS 1 GENERAL SYSTEM DESCRIPTION SYSTEM DESCRIPTION: In accordance
More informationSeptember 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901
September 3, 2009 Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 RE: Ketchikan Gateway Borough Gateway Recreation Center Roof Observations and Intrusive Inspections
More informationTable of Contents PART 1 WINDOW SELECTION GUIDE. Window and Door Selection Guide
VOLUME 1 - WINDOWS AND DOORS Window and Door Selection Guide PART 1 WINDOW SELECTION GUIDE WSG-11 PART 2 - PERFORMANCE SPECIFICATIONS Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows
More informationThe Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.
26 D+D MARCH 2015 Building Envelope Roland Serino, P.E., Dryvit Systems Inc. here has always been a need for a more efficient way to build in large cities like Chicago, New York, Los Angeles or other central
More informationTARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
More informationJames M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
More informationSL30-ISO PROFILE SYSTEM
AESTHETICS AND sustainability SL30-ISO PROFILE SYSTEM TECHNICAL DOCuMENTATION WWW.MHB.NL SL30-ISO PROFILE SYSTEM 1. SL30-ISO and SL30-ISO-PLUS Sustainability is getting worldwide more and more the attention
More informationTABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"
2 TABLE OF CONTENTS SECTION 1: What is a Standing Seam Metal Roof PAGE 3 SECTION 2: Common Types of Standing Seam Metal Roofs..PAGE 5 SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE
More informationAll Weather Hall. Efficient, multipurpose & quick to build
All Weather Hall Efficient, multipurpose & quick to build ALL WEATHER HALL www.deboer.com www.deboer.com ALL WEATHER HALL A flexible solution for a multitude of needs All Weather halls from De Boer provide
More informationArmanet BEKAERT. Armanet THE CONSTRUCTIVE IDEA. Render & plaster reinforcing mesh @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@
BEKAERT Armanet THE CONSTRUCTIVE IDEA Armanet Render & plaster reinforcing mesh Armanet Renovation Product specification Insulation Reinforcing Mesh Armanet is a heavily galvanized welded mesh used for
More informationORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS
GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS ~GSM SHELTER CONTAINERS ARE PROCUDED ACCORDING TO THE DEMANDED SIZE.~ (W x L x H) Page1 GENERAL FEAUTURES Environmental Conditions : Maximum outdoor temperature
More informationBuilding Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings
BUILDING ENVELOPE DESIGN BY ROXUL Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB Exterior
More informationBuilding Owners Guide to a Duro-Last System!
Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof
More informationSECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
More informationVer. 2. Guide to. Inspecting Residential Brick Veneer
Ver. 2 Guide to Inspecting Residential Brick Veneer 1. A guide created by industry professionals. The knowledgeable staff at MASONPRO together with technical support from the Masonry Institute of Michigan
More informationLindab Seamline Application guide. Lindab Seamline TM. Lindab Standing Seam Roofing Application guide
Lindab Seamline Application guide Lindab Seamline TM Lindab Standing Seam Roofing Application guide This handbook deals with long strip roofing with HB Polyester and aluminiumzinc on a boarded roof covering.
More informationTable of Contents. I. Roof Scuttles
Table of Contents I. 1. Specification Guidelines 2. Bilco Quote/Order Checklist 3. Target Markets 4. Product Training 5. Benefits/Features 6. Scuttle Handrails Specification Guidelines Key Bilco features
More informationSpecifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023
Specifications Preformed Metal Wall and Roof Panels Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Section 07410 Preformed Metal Wall and Roof Panels Structural
More informationAsphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
More informationCHANNEL LETTERING INDOOR & OUTDOOR TRADE SHOW DISPLAYS CONSTRUCTION SIGNAGE VEHICLE GRAPHICS REAL ESTATE / DISPLAYS WINDOW GRAPHICS POSTERS
CHANNEL LETTERING INDOOR & OUTDOOR SIGNAGE TRADE SHOW DISPLAYS CONSTRUCTION SIGNAGE VEHICLE GRAPHICS REAL ESTATE / DISPLAYS WINDOW GRAPHICS POSTERS info@muizgraphics.com www.muizgraphics.com Tel: 905-362-0268
More informationDESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS 08 50 00 WINDOWS
SECTION INCLUDES Metal Windows Vinyl/Aluminum Clad Wood Windows Solid Fiberglass and Vinyl Windows Wood Windows (Historic Preservation only) RELATED SECTIONS 02 83 00 Lead Paint Remediation 06 10 00 Rough
More informationMarch 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
More informationChapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
More informationRoof Curbs, Extensions and Equipment Supports
Roof s, Extensions and Equipment Supports December 2012 Roof Page s, Header Extensions and Equipment Supports Table of Contents Model GPI Standard and Optional Construction Features... 3 Model Number Code....
More informationTable of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..
Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
More informationASME Packaged Indirect Fired Water Heater
Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining
More informationDrexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed
More informationAutomotive Engineered Attachment Systems
Automotive Engineered Attachment Systems (TR-12721) Technical Data Sheet Acrylic Foam RT8000 Series General Information : The acrylic Foam RT8000 Series, which is made by a special process, has a superior
More informationBuilding Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings
Building Envelope Design using ROXUL Building Envelope Design using ROXUL (BEDR ) FIREWALL and ROXUL PLUS MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB
More informationSECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
More informationmetal Duil~ing manufacturers Association
metal Duil~ing manufacturers Association ApplicatiDns metal Building Systems Conventional Buildings Retrofit Roofing Projects l~e Perfect Cover.One of the most important technological advances in building
More informationCHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
More informationTITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09
TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09 PMT GUIDE # 10 Book of Order Section G-10.0102o: "The session is responsible for the mission and government of the particular church. It
More information2.3. Continuous Hot-Dip Galvanizing versus General (Batch) Galvanizing Rev 1.0 Jan 2011. GalvInfoNote. Introduction. Continuous Galvanizing
2. Coating Processes and Surface Treatments GalvInfoNote 2.3 Introduction Continuous Hot-Dip Galvanizing versus General (Batch) Galvanizing There are two different processes for applying a zinc coating
More informationMark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
More informationPrefabricated building PVC vertical sliding window
Prefabricated building PVC vertical sliding window SLOVENSKO ITALIA ESPAÑA ITALIA The company, we have the pleasure to introduce in this brochure, is an important and dynamic industrial company located
More informationGUIDELINE SPECIFICATIONS
GUIDELINE SPECIFICATIONS GORDON SOFFIT-SHIELD - An Exterior Metal Soffit System DIVISION 05 5800 or DIVISION 07 7700 Note To Specifier: SOFFIT-SHIELD should be installed by tradesmen that are experienced
More informationMaster Panel 1000 R5 Roof
Master Panel 1000 R5 Roof Product Description The important feature of the roof elements are the easy installation procedure. The element fix exactly and pushed together without much force. Roof coverage
More informationMechanical arms, belts and sheets
Car parks Mechanical arms, belts and sheets DETAIL ARM CAR PARK (mm) 5000 Platen 100x5mm Iron sheets 4mm 5000 485 2100 Belts type C 120x50x2 mm 4915 5400 Hot dipped galvanized UNE-EN ISO 1461 or black
More informationMetal Building Systems Installation and Flashings & Details Guide. Table of Contents
Table of Contents Section Page Notes to Designer/User..................1-2 Map of Typical Roof Conditions............3 Fastener Placement.......................4 Fastener Selection........................5
More informationROOFS - Guidance for Repair, Maintenance and Replacement
ROOFS - Guidance for Repair, Maintenance and Replacement Guilford Association Architectural Committee ROOFING Slate and tile roofs are a critical design feature of Guilford homes. The homes were designed
More informationRPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
More informationAnodes and Misc Equipment
Anodes and Misc Equipment Application: Platinised Titanium Anodes Platinised titanium anodes are recommended for use in the following electrolytic processes:- Precious metal electroplating - e.g. Au, Pt,
More informationCF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...
Building Insulations - Walls and Ceilings (FM Approval Numbers 4411, 4651, 4880, 4881, 4882) Insulating materials may occur in building construction to reduce heat or sound transmission through a wall,
More informationFire Resistant Systems
Fire Resistant Systems A R C H I T E C T U R A L A L U M I N I U M G L A Z I N G S Y S T E M S Fire Resistant Systems Introduction Kawneer are pleased to introduce two new comprehensive Fire Resistant
More informationUNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design
Basis of Design This section applies to roofing membranes, flashing and accessories. Design Criteria Adhere to the standards and details of the latest editions of the National Contractors Association (NRCA)
More informationINSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings
INSULATION FOR PRE-ENGINEERED METAL BUILDINGS ROXUL SAFE 55 & 65 and ROXUL PLUS MB Insulation for Pre-Engineered Metal Buildings ROXUL SAFE AND ROXUL PLUS MB Exterior Wall Insulation for Pre-Engineered
More informationCONDENSATION IN REFRIDGERATED BUILDINGS
CONDENSATION IN REFRIDGERATED BUILDINGS By: Steve Salisbury Nov. 10, 2010 (revised Nov. 14, 2013) Introduction The following discussion reviews the basic causes of condensation in refrigerated buildings
More informationInsulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW
Insulated Roof & Wall Panels Trapezoidal Insulated Roof Panels KS1000 RW Overview Kingspan roof panel systems present a superior system compared to conventional multi-part site assembled systems. They
More informationRESIDENTIAL MASONRY A BEST PRACTICES GUIDE
RESIDENTIAL MASONRY A BEST PRACTICES GUIDE Build With Brick Build With Boral CONTENTS BRICK :01 MASONRY CEMENT :03 MASONRY SAND :04 WALL TIES :05 STEEL LINTELS :07 DRAINAGE WALL SYSTEM :09 FLASHING :11
More informationPVC in automotive. Examining the trends and drivers behind the growth of PVC for dashboard applications
PVC in automotive Examining the trends and drivers behind the growth of PVC for dashboard applications Summary Introduction The evolution of PVC-slush: past & present How PVC meets the increasingly stringent
More informationFinal inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
More informationSince 1978. HMT Inc. 24 Waterway Avenue, Suite 400 The Woodlands, Texas 77380 Ph: +1.281.681.7000 Fax: +1.281.419.7689
WaTER & wastewater HMT Inc. 24 Waterway Avenue, Suite 400 The Woodlands, Texas 77380 Ph: +1.281.681.7000 Fax: +1.281.419.7689 Locations worldwide to service all your needs. VAPORVAULT and ALUMINATOR are
More informationUbiflex. Non-lead flashing system
Ubiflex Non-lead flashing system Ubiflex non-lead flashing Ubiflex is a non-lead waterproof flashing material which can be used in most applications where lead is traditionally used to provide a weatherproof
More informationitaltec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines
PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals
More informationPART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
More informationRemovable Insulation Blankets from A to Z
Removable Insulation Blankets from A to Z At first glance, making up a removable insulation blanket seems somewhat simple take some insulation, put some mesh on one side, a cover on the other, sew them
More informationRockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
More informationTIGER Drylac U.S.A., Inc. 3855 Swenson Avenue St Charles, IL T 800 243 8148 F 877 926 8148 office.us@tiger-coatings.us www.tiger-coatings.
Product Data Sheet SERIES 69 - DRYZINC ZINC-RICH PRIMER (69/90500) Epoxy zinc-rich powder coating primer. Part of a two-coat TIGER Shield system. Designed to impart superior corrosion protection to steel
More informationexpectation as hot dip galvanizing?
FREQUENTLY ASKED QUESTIONS ********************************* Q. 1.What exactly is Cold galvanizing? A. Cold galvanisation is an organic, single-component zinc coating of minimum 92% (weight) zinc in the
More informationConfort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
More informationLight Architecture. Colors Sweden. Light
Light Architecture Danpalon is the complete daylighting solution offering exceptional quality of light, thermal insulation and UV protection with a rich non-industrial visual appeal. The Danpalon system
More informationRuukki Finnera. The most intelligent roof ever seen.
Ruukki Finnera The most intelligent roof ever seen. Finnera s new and innovative design makes your steel roof not only beautiful but also extremely durable and practical. The revolutionary front-edge folding
More informationDissimilar Metal Corrosion
PDHonline Course S118 (1 PDH) Dissimilar Metal Corrosion Instructor: D. Matthew Stuart, P.E., S.E., F.ASCE, F.SEI, SECB, MgtEng 2013 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658
More informationBIS Metal Pipe Clamps with Lining
A BIS Metal Pipe Clamps with Lining BIS Clamps BISMAT Flash BISMAT 2000 Ø ¼ - 2" BISMAT 2000 Ø 2½ - 4" 2 3 4 BIS Industrial Clamps BIS Heavy Duty Clamps HD1501 (1/2") (BUP1000) 5 BIS Clamps for Plastic
More informationTable of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide
Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
More informationPROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick
1. SCOPE OF WORK The scope of work includes the design, supply fabrication and installation of Alucobond PLUS aluminium composite panel cladding, complete with all necessary sub-structures, anchors, hardware
More informationLow-slope reroofing guidelines
Low-slope reroofing guidelines by Thomas Bollnow and Joan P. Crowe, AIA The NRCA Roofing and Waterproofing Manual, Fifth Edition, contains reroofing guidelines for steep- and low-slope roofing. The August
More informationLarry Haight's Residential Roofing Co, Inc 15203 NE 95th Street Redmond, Washington Phone: (425) 881-9771 Fax: (425) 869-1010
Larry Haight's Residential Roofing Co, Inc 15203 NE 95th Street Redmond, Washington Phone: (425) 881-9771 Fax: (425) 869-1010 Custom bid generated for: Job site address: Lake Villas Condominium Attention:
More informationResidential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...
More informationMTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS
Los Angeles, CA Project Manual and Specification DIVISION 1 GENERAL CONDITIONS 01 01 10 STATEMENT OF WORK 01 11 00 SUMMARY OF THE WORK 01 14 05 METRO (OWNER) - DIRECTED STOPPAGES 01 20 00 PRICE AND PAYMENT
More informationColonnade Security Pipe
Description: Round & Square downpipe formed from extruded 6060 T4 aluminium in various sizes (Ø83mm, Ø108mm, 83x83 mm & 108x108mm*) & supplied with a complete range of accessories i.e. Offsets, bends,
More informationK2 STONE NATURAL VENEER
INTRODUCTION WHAT IS K2 NATURAL THINSTONE VENEER? Natural K2 Stone veneer is real stone, cut 1 inch thick, making it light enough to be installed as a veneer. Sometimes referred to as thin veneer, thin
More informationA. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.
13310 FABRIC SHADE STRUCTURES FOR PLAYGROUND AREAS ************************************************************************************************************************ SPECIFIER: CSI Master Format
More informationSECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. This section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,
More informationModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape
ModuSec Secure and efficient IT room solutions Turnkey Modular Construction Fast clean build to any size or shape Room in room Standalone external build Transportable Modusec SR Options Modusec SR Options
More informationSECTION 07400 STANDING SEAM METAL ROOF
SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and
More informationProtecting YOUR NEW HOME FROM Wind Damage
Protecting YOUR NEW HOME FROM Wind Damage Blueprint for Safety... A Blueprint for Life When severe weather threatens, protecting life and property automatically becomes top priority for millions of Florida
More informationSPRINKLER TANKS MOSTOSTALEX TECHNICAL SPECIFICATION. Manufacture» Delivery» Assembling» Service
SPRINKLER TANKS (Polish Scientific and Research Centre for Fire Protection Report no 4033/BS/08) TECHNICAL SPECIFICATION Manufacture» Delivery» Assembling» Service MOSTOSTALEX Warsaw 5.2009 1 / 8 DESIGN
More informationResidential Garage Door Terminology
A Air Infiltration: The leakage or passage of air through a door system Anodize: A hard non-corrosive oxide film on the surface of aluminum Astragal: A compressible or deformable seal provided on the bottom
More informationArchitectural Inspection Site Structures
0141 Freestanding Shelters Open air shelters not attached to the building. Bike rack shelter with bike racks: This 8'x30' structure is located on the north east side of the building on the wooded landscape
More informationSECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
More informationMaster Panel 1000 W Wall
Master Panel 1000 W Wall Product Description In order to generate an aesthethic outlook wall panels are generally produced as micro hedge. Besides, in connection points concealed screw is used which provides
More informationCERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED
CERTIFICATE OF APPROVAL No CF 291 This is to certify that, in accordance with TS General Requirements for Certification of Fire Protection Products The undermentioned products of Drummond Road, Stafford.
More informationSECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
More informationRegulatory Services. Asbestos in the Home. What is asbestos?
Regulatory Services Asbestos in the Home What is asbestos? Asbestos is a natural silicate mineral consisting of fibres. The fibres are strong, durable, and resistant to heat, long, thin and flexible. There
More informationThe Perfect Fit For Metal Retrofit
D u r o - S h i e l d M e t a l R e t r o f i t R o o f i n g S y s t e m The Perfect Fit For Metal Retrofit Lock out leaks. Lock in your investment. Has time caught up with your metal roof? There are
More informationThe existing roof angle change terminations and flashings when sound and intact can be reused.
January 2, 2015 Summary Specification Re-Skinning an Existing Roof Maintenance and Repair Warranty Upgrade for Up to 30 Years Re-Skinning Over an Existing Roof with a New C-EPDM Membrane Using The Existing
More information