SAR MEASUREMENT RESULTS

Size: px
Start display at page:

Download "SAR MEASUREMENT RESULTS"

Transcription

1 SAR MEASUREMENT RESULTS This page summarizes the results of the performed dosimetric evaluation. SAR Test Data Environmental Conditions Temperature: Relative Humidity: ATM Pressure: C mbar * Testing was performed by Sandy Wang on to WCDMA850 Band: EUT Position EUT (MHz) Test Mode Antenna Information Channel MHz Phantom Power FCC 1g SAR Drift (W/Kg) ( ) Meas. Limit Left Head Cheek Left Head Tilt Right Head Cheek Right Head Tilt Body-Front-Headset (10mm) Body-Back-Headset (10mm) Note: Mobile Phone WCDMA850 Integral SAM Mobile Phone+ Anti-Radiation mobile phone case/sticker WCDMA850 Integral SAM Mobile Phone WCDMA850 Integral SAM Mobile Phone+ Anti-Radiation mobile phone case/sticker WCDMA850 Integral SAM Mobile Phone WCDMA850 Integral SAM Mobile Phone+ Anti-Radiation mobile phone case/sticker WCDMA850 Integral SAM Mobile Phone WCDMA850 Integral SAM Mobile Phone+ Anti-Radiation mobile phone case/sticker WCDMA850 Integral SAM Mobile Phone WCDMA850 Integral Universal Mobile Phone+ Anti-Radiation mobile phone case/sticker WCDMA850 Integral Universal Mobile Phone WCDMA850 Integral Universal Mobile Phone+ Anti-Radiation mobile phone case/sticker WCDMA850 Integral Universal When the 1-g SAR is 0.8W/Kg, testing for other channels are optional. 1.6 SAR Evaluation Report 33 of 101

2 WCDMA1900 Band: EUT Position EUT (MHz) Test Mode Antenna Information Channel MHz Phantom Power FCC 1g SAR Drift (W/Kg) ( ) Meas. Limit Left Head Cheek Left Head Tilt Right Head Cheek Right Head Tilt Mobile Phone WCDMA1900 Integral SAM Mobile Phone+ Anti-Radiation mobile phone case/sticker WCDMA1900 Integral SAM Mobile Phone WCDMA1900 Integral SAM Mobile Phone+ Anti-Radiation mobile phone case/sticker WCDMA1900 Integral SAM Mobile Phone WCDMA1900 Integral SAM Mobile Phone+ Anti-Radiation mobile phone case/sticker WCDMA1900 Integral SAM Mobile Phone WCDMA1900 Integral SAM Mobile Phone+ Anti-Radiation mobile phone case/sticker Mobile Body-Front-Headset Phone+ (10mm) Anti-Radiation mobile phone case/sticker Mobile Body-Back-Headset Phone+ (10mm) Anti-Radiation mobile phone case/sticker Note: WCDMA1900 Integral SAM Mobile Phone WCDMA1900 Integral Universal WCDMA1900 Integral Universal Mobile Phone WCDMA1900 Integral Universal WCDMA1900 Integral Universal When the 1-g SAR is 0.8W/Kg, testing for other channels are optional. 2. The default test configuration is to measure SAR with an established radio link between the EUT and a communication test set using a 12.2 kbps RMC (reference measurement Channel) Configured in Test Loop Model 1. SAR Radiation reduced 95% based the FCC Safety Standard 1.6 SAR Evaluation Report 34 of 101

3 EUT SCAN RESULTS WCDMA850; Left Head Cheek (836.6 MHz Middle Channel); Mobile Phone : WCDMA850 Scan : 11x7x1: Measurement x=10mm, y=10mm, z=4mm : 7x7x7: Measurement x=5mm, y=5mm, z=5mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : MHz : F/m : 0.91 S/m Band : 835 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 1# SAR Evaluation Report 35 of 101

4 WCDMA850; Left Head Cheek (836.6 MHz Middle Channel); Mobile Phone+ Anti-Radiation mobile phone case/sticker : WCDMA850 Scan : 11x7x1: Measurement x=10mm, y=10mm, z=4mm : 7x7x7: Measurement x=5mm, y=5mm, z=5mm Power Drift-Start : W/kg Power Drift-Finish : 0.254W/kg Power Drift (%) : : MHz : F/m : 0.91 S/m Band : 835 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 2# SAR Evaluation Report 36 of 101

5 WCDMA850: Left Head Tilt (836.6 MHz Middle Channel); Mobile Phone : WCDMA850 Scan : 11x7x1: Measurement x=10mm, y=10mm, z=4mm : 7x7x7: Measurement x=5mm, y=5mm, z=5mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : MHz : F/m : 0.91 S/m Band : 835 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 3# SAR Evaluation Report 37 of 101

6 WCDMA850; Left Head Tilt (836.6 MHz Middle Channel); Mobile Phone+ Anti-Radiation mobile phone case/sticker : WCDMA850 Scan : 11x7x1: Measurement x=10mm, y=10mm, z=4mm : 7x7x7: Measurement x=5mm, y=5mm, z=5mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : MHz : F/m : 0.91 S/m Band : 835 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 4# SAR Evaluation Report 38 of 101

7 WCDMA850; Right Head Cheek (836.6 MHz Middle Channel); Mobile phone : WCDMA850 Scan : 11x7x1: Measurement x=10mm, y=10mm, z=4mm : 7x7x7: Measurement x=5mm, y=5mm, z=5mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : MHz : F/m : 0.91 S/m Band : 835 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 5# SAR Evaluation Report 39 of 101

8 WCDMA850; Right Head Cheek (836.6 MHz Middle Channel); Mobile Phone+ Anti-Radiation mobile phone case/sticker : WCDMA850 Scan : 11x7x1: Measurement x=10mm, y=10mm, z=4mm : 7x7x7: Measurement x=5mm, y=5mm, z=5mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : MHz : F/m : 0.91 S/m Band : 835 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 6# SAR Evaluation Report 40 of 101

9 WCDMA850; Right Head Tilt (836.6 MHz Middle Channel); Mobile phone : WCDMA850 Scan : 11x7x1: Measurement x=10mm, y=10mm, z=4mm : 7x7x7: Measurement x=5mm, y=5mm, z=5mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : MHz : F/m : 0.91 S/m Band : 835 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 7# SAR Evaluation Report 41 of 101

10 WCDMA850; Right Head Tilt (836.6 MHz Middle Channel); Mobile Phone+ Anti-Radiation mobile phone case/sticker : WCDMA850 Scan : 11x7x1: Measurement x=10mm, y=10mm, z=4mm : 7x7x7: Measurement x=5mm, y=5mm, z=5mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : MHz : F/m : 0.91 S/m Band : 835 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 8# SAR Evaluation Report 42 of 101

11 WCDMA850; Body-worn Front (836.6 MHz Middle Channel); Mobile phone : WCDMA850 Scan : 8x11x1 : Measurement x=10mm, y=10mm, z=4mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : Body : MHz : F/m : 0.96 S/m Band : 835 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 9# SAR Evaluation Report 43 of 101

12 WCDMA850; Body-worn Front (836.6 MHz Middle Channel); Mobile Phone+ Anti-Radiation mobile phone case/sticker : WCDMA850 Scan : 8x11x1 : Measurement x=10mm, y=10mm, z=4mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : Body : MHz : F/m : 0.96 S/m Band : 835 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 10# SAR Evaluation Report 44 of 101

13 WCDMA850; Body-worn Back (836.6 MHz Middle Channel); Mobile phone : WCDMA850 Scan : 8x11x1 : Measurement x=10mm, y=10mm, z=4mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : Body : MHz : F/m : 0.96 S/m Band : 835 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 11# SAR Evaluation Report 45 of 101

14 WCDMA850; Body-worn Back (836.6 MHz Middle Channel); Mobile Phone+ Anti-Radiation mobile phone case/sticker : WCDMA850 Scan : 8x11x1 : Measurement x=10mm, y=10mm, z=4mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : Body : MHz : F/m : 0.96 S/m Band : 835 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 12# SAR Evaluation Report 46 of 101

15 WCDMA1900; Left Head Cheek ( MHz Middle Channel); Mobile phone : WCDMA1900 Scan : 11x7x1 : Measurement x=10mm, y=10mm, z=4mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : MHz : F/m : 1.43 S/m Band : 1900 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 13# SAR Evaluation Report 47 of 101

16 WCDMA1900; Left Head Cheek ( MHz Middle Channel); Mobile Phone+ Anti-Radiation mobile phone case/sticker : WCDMA1900 Scan : 11x7x1 : Measurement x=10mm, y=10mm, z=4mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : MHz : F/m : 1.43 S/m Band : 1900 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 14# SAR Evaluation Report 48 of 101

17 WCDMA1900; Left Head Tilt ( MHz Middle Channel); Mobile phone : WCDMA1900 Scan : 11x7x1 : Measurement x=10mm, y=10mm, z=4mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : MHz : F/m : 1.43 S/m : kg/cu. M Band : 1900 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 15# SAR Evaluation Report 49 of 101

18 WCDMA1900; Left Head Tilt ( MHz Middle Channel); Mobile Phone+ Anti-Radiation mobile phone case/sticker : WCDMA1900 Scan : 11x7x1 : Measurement x=10mm, y=10mm, z=4mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : MHz : F/m : 1.43 S/m : kg/cu. M Band : 1900 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 16# SAR Evaluation Report 50 of 101

19 WCDMA1900; Right Head Cheek ( MHz Middle Channel); Mobile phone : WCDMA1900 Scan : 11x7x1 : Measurement x=10mm, y=10mm, z=4mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : MHz : F/m : 1.43 S/m Band : 1900 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 17# SAR Evaluation Report 51 of 101

20 WCDMA1900; Right Head Cheek ( MHz Middle Channel); Mobile Phone+ Anti-Radiation mobile phone case/sticker : WCDMA1900 Scan : 11x7x1 : Measurement x=10mm, y=10mm, z=4mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : MHz : F/m : 1.43 S/m Band : 1900 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 18# SAR Evaluation Report 52 of 101

21 WCDMA1900; Right Head Tilt ( MHz Middle Channel); Mobile phone : WCDMA1900 Scan : 11x7x1 : Measurement x=10mm, y=10mm, z=4mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : MHz : F/m : 1.43 S/m : kg/cu. M Band : 1900 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 19# SAR Evaluation Report 53 of 101

22 WCDMA1900; Right Head Tilt ( MHz Middle Channel); Mobile Phone+ Anti-Radiation mobile phone case/sticker : WCDMA1900 Scan : 11x8x1 : Measurement x=10mm, y=10mm, z=4mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : MHz : F/m : 1.43 S/m : kg/cu. M Band : 1900 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 20# SAR Evaluation Report 54 of 101

23 WCDMA1900; Body-worn Front ( MHz Middle Channel); Mobile phone : WCDMA1900 Scan : 8x11x1 : Measurement x=10mm, y=10mm, z=4mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : Body : MHz : F/m : 1.52 S/m Band : 1900 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 21# SAR Evaluation Report 55 of 101

24 WCDMA1900; Body-worn Front( MHz Middle Channel); Mobile Phone+ Anti-Radiation mobile phone case/sticker : WCDMA1900 Scan : 8x11x1 : Measurement x=10mm, y=10mm, z=4mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : Body : MHz : F/m : 1.52 S/m Band : 1900 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 22# SAR Evaluation Report 56 of 101

25 WCDMA1900; Body-worn Back ( MHz Middle Channel); Mobile phone : WCDMA1900 Scan : 8x11x1 : Measurement x=10mm, y=10mm, z=4mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : Body : MHz : F/m : 1.52 S/m Band : 1900 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 23# SAR Evaluation Report 57 of 101

26 WCDMA1900; Body-worn Back ( MHz Middle Channel); Mobile Phone+ Anti-Radiation mobile phone case/sticker : WCDMA1900 Scan : 8x11x1 : Measurement x=10mm, y=10mm, z=4mm Power Drift-Start : W/kg Power Drift-Finish : W/kg Power Drift (%) : : Body : MHz : F/m : 1.52 S/m Band : 1900 Conversion Factor : gram SAR value : W/kg 10 gram SAR value : W/kg Peak SAR : W/kg Peak SAR : W/kg Plot 24# SAR Evaluation Report 58 of 101

27 APPENDIX A MEASUREMENT UNCERTAINTY The uncertainty budget has been determined for the measurement system and is given in the following Table. Measurement Uncertainty for 300MHz to 3GHz Source of Uncertainty Tolerance Value Probability Distribution Divisor Measurement System c i 1 (1-g) c i 1 (10-g) Standard Uncertainty (1-g) % Standard Uncertainty (10-g) % Probe Calibration 3.5 normal Axial Isotropy 3.7 rectangular 3 (1-cp) 1/2 (1-cp) 1 / Hemispherical Isotropy 10.9 rectangular 3 cp cp Boundary Effect 1.0 rectangular Linearity 4.7 rectangular Detection Limit 1.0 rectangular Readout Electronics 1.0 normal Response Time 0.8 rectangular Integration Time 1.7 rectangular RF Ambient Condition -Noise RF Ambient Condition - Reflections Probe Positioner Mech. Restrictions Probe Positioning with respect to Phantom Shell Extrapolation and Integration rectangular rectangular rectangular Restriction 2.9 rectangular rectangular Test Sample Positioning normal Device Holder Uncertainty normal Drift of Output Power rectangular Phantom Uncertainty(shape & thickness tolerance) Liquid Conductivity(target) Liquid Conductivity(meas.) Liquid Permittivity(target) Liquid Permittivity(meas.) Phantom and Setup 3.4 rectangular rectangular normal rectangular normal Combined Uncertainty RSS Expanded uncertainty (coverage factor=2) Normal(k=2) SAR Evaluation Report 59 of 101

CERTIFICATE OF COMPLIANCE SAR EVALUATION

CERTIFICATE OF COMPLIANCE SAR EVALUATION 802 N. Twin Oaks Valley Road, Suite 105 San Marcos, CA 92069 U.S.A. TEL (760) 471-2100 FAX (760) 471-2121 http://www.rfexposurelab.com CERTIFICATE OF COMPLIANCE SAR EVALUATION LS Research Dates of Test:

More information

SAMSUNG GT-S5369 (mobile phone) Serial number: IMEI 358858043716587. Mr. Antoine SAMAKH and Mr. Mathieu SAMAKH 92100 FRANCE

SAMSUNG GT-S5369 (mobile phone) Serial number: IMEI 358858043716587. Mr. Antoine SAMAKH and Mr. Mathieu SAMAKH 92100 FRANCE R052-DAS-12-104374-7/A Ed. 1 This report cancels and replaces the test report R052-DAS-12-104374-7/A Ed. 0 SAR TEST REPORT According to the standard: EN 62209-1: 2006 Equipment under test: Antenna patch

More information

EN 50360:2001+A1:2012 SAR EVALUATION REPORT. Baoji Jiayuyutong electronic co.,ltd

EN 50360:2001+A1:2012 SAR EVALUATION REPORT. Baoji Jiayuyutong electronic co.,ltd EN 50360:2001+A1:2012 SAR EVALUATION REPORT For Baoji Jiayuyutong electronic co.,ltd Building A, 28# Longteng Street, Jianyi Village, Henggang Town, Longgang District, Shenzhen, P. R. China Model: JY-S3

More information

SAR TEST REPORT. According to the standard: EN 62209-1: 2006

SAR TEST REPORT. According to the standard: EN 62209-1: 2006 R052-DAS-12-104374-2/A Ed. 1 This report cancels and replaces the test report R052-DAS-12-104374-2/A Ed. 0 SAR TEST REPORT According to the standard: EN 62209-1: 2006 Equipment under test: Antenna patch

More information

SAR Test Report: Type Number FAD-3022012-BV; FCC ID PY7FD022012; IC 4170B-FD022012

SAR Test Report: Type Number FAD-3022012-BV; FCC ID PY7FD022012; IC 4170B-FD022012 1 (34) Report issued by an Accredited Laboratory Rapport utfärdad av ett ackrediterat laboratorium This laboratory is accredited to SS-EN ISO/IEC 17025 (SWEDAC accreditation no. 1761). SAR Test Report:

More information

How To Understand The Safety Of A Cell Phone (Cell Phone)

How To Understand The Safety Of A Cell Phone (Cell Phone) Compliance Testing of Mobile Phones Masao Taki Tokyo Metropolitan University JAPAN Outline Exposure Standards/Guidelines Product Standard of MTE and Standard Procedures of Compliance Testing Some remarks

More information

Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands)

Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) Issue 3 June 2009 Spectrum Management and Telecommunications Radio Standards Specification Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) Aussi disponible

More information

September 26, 2000 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort

September 26, 2000 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort TTI-P-G 158 Report Dosimetric Assessment of the Mobile Ericsson T18z with an without the PAM System Technologies devices According to the American FCC Requirements September 26, 2000 IMST GmbH Carl-Friedrich-Gauß-Str.

More information

DECLARATION OF COMPLIANCE - SAR RF EXPOSURE EVALUATION - EU EN 62311:2008

DECLARATION OF COMPLIANCE - SAR RF EXPOSURE EVALUATION - EU EN 62311:2008 DECLARATION OF COMPLIANCE - SAR RF EXPOSURE EVALUATION - EU EN 62311:2008 Test Lab Information Name Address CELLTECH LABS INC. 21-364 Lougheed Road, Kelowna, B.C. V1X 7R8 Canada Test Lab Accreditation(s)

More information

Overview of RF Exposure Concepts and Requirements

Overview of RF Exposure Concepts and Requirements Overview of RF Exposure Concepts and Requirements Kwok Chan Technical Research Branch Federal Communications Commission Office of Engineering and Technology Laboratory Division Note: hyperlinks may not

More information

Body SAR and EU. B. Derat

Body SAR and EU. B. Derat Body SAR and EU B. Derat Overview / Outline New Approach: Directive / Standards Current applicable standard IEC/EN 62209-2:2010 Tablet case study Future of EU body SAR testing Maintenance of IEC 62209-2

More information

SAR TEST REPORT. No. I14D00063-SAR. For. Client : ZTE Corporation. Production : LTE/WCDMA/GSM Multi-Mode. Digital Mobile Phone

SAR TEST REPORT. No. I14D00063-SAR. For. Client : ZTE Corporation. Production : LTE/WCDMA/GSM Multi-Mode. Digital Mobile Phone SAR TEST REPORT No. I14D00063-SAR For Client : ZTE Corporation Production : LTE/WCDMA/GSM Multi-Mode Digital Mobile Phone Model Name : ZTE Blade A430 Hardware Version: WMBQ Software Version: ZTE-CN-QB18S-P632A10V0.0.1B01L1

More information

Millennium Product Inc. Model: Cell Shield / Zorb

Millennium Product Inc. Model: Cell Shield / Zorb Millennium Product Inc. Cell Shield / Zorb Prepared by PCTEST LAB Issued on: 10/22/2015 Report Version 2.6 NOTE: SAR results only apply to the device tested. Although the device may have had different

More information

RF Exposure Procedures TCB Workshop October 2012

RF Exposure Procedures TCB Workshop October 2012 RF Exposure Procedures TCB Workshop October 2012 Laboratory Division Office of Engineering and Technology Federal Communications Commission Overview Further updates on the RF exposure KDB drafts released

More information

Federal Communications Commission Office of Engineering and Technology Laboratory Division Public Draft Review

Federal Communications Commission Office of Engineering and Technology Laboratory Division Public Draft Review April 23, 2012 Federal Communications Commission Office of Engineering and Technology Laboratory Division Public Draft Review Draft Laboratory Division Publications Report Title: General RF Exposure Policies

More information

For many years the general public

For many years the general public David Seabury, ETS-Lindgren An Update On SAR Standards And The Basic Requirements For SAR Assessment For many years the general public has been concerned about the possible health effects of exposure to

More information

RF EXPOSURE PROCEDURES AND EQUIPMENT AUTHORIZATION POLICIES FOR MOBILE AND PORTABLE DEVICES

RF EXPOSURE PROCEDURES AND EQUIPMENT AUTHORIZATION POLICIES FOR MOBILE AND PORTABLE DEVICES Federal Communications Commission Office of Engineering and Technology Laboratory Division October 23, 2015 RF EXPOSURE PROCEDURES AND EQUIPMENT AUTHORIZATION POLICIES FOR MOBILE AND PORTABLE DEVICES Table

More information

Federal Communications Commission Office of Engineering and Technology Laboratory Division

Federal Communications Commission Office of Engineering and Technology Laboratory Division October 24, 2012 Federal Communications Commission Office of Engineering and Technology Laboratory Division Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies Table

More information

SAR Comparison Report

SAR Comparison Report Page: 1 of 12 SAR Comparison Report Reference Number: 3103519 Report Number: 3103519EMC01 Revision Level: 0 Client: Lifewave Equipment Under Test: Model Name: Matrix 2 Test Protocol: SAR Comparison Report

More information

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT For SAMBO HI TECH CO., LTD. 616-15, GANSUK4-DONG, NAMDONG-GU, INCHUN 405-810, KOREA Model: LSR700, SCI545HV1EF, SCI545HVEF This Report Concerns: Original

More information

FCC OET BULLETIN 65 SUPPLEMENT C 01-01 IEEE Std 1528-2003 and 1528a-2005. (Class II Permissive Change) SAR EVALUATION REPORT. For.

FCC OET BULLETIN 65 SUPPLEMENT C 01-01 IEEE Std 1528-2003 and 1528a-2005. (Class II Permissive Change) SAR EVALUATION REPORT. For. FCC OET BULLETIN 65 SUPPLEMENT C 01-01 IEEE Std 1528-2003 and 1528a-2005 (Class II Permissive Change) SAR EVALUATION REPORT For Glass Model: XEB Report Number: 13U14955-5A Issue Date: 4/15/2013 Prepared

More information

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA

More information

Specific Absorption Rate (SAR) Induced in Human Heads of Various Sizes When Using a Mobile Phone

Specific Absorption Rate (SAR) Induced in Human Heads of Various Sizes When Using a Mobile Phone , June 30 - July 2, 2010, London, U.K. Specific Absorption Rate (SAR) Induced in Human Heads of Various Sizes When Using a Mobile Phone Adel Z. El Dein Alaeddin Amr Abstract - This paper analyzes the specific

More information

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz J. Klima, R. Ščehovič Department of Physics, Faculty of Natural Sciences, University of Mathias Bel, Tajovského

More information

Human Exposure Limits

Human Exposure Limits Human Exposure Limits Session 3 0 Version December 2014 Learning objectives In this session we will: Learn about the international exposure limits for workers and the public Learn about methods for assessing

More information

Specific Absorption Rate (SAR) Test Report

Specific Absorption Rate (SAR) Test Report Specific Absorption Rate (SAR) Test Report for FIC (First International Computer, Inc.) on the Neo FreeRunner Report No. : EA832514 Trade Name : OPENMOKO Model Name : GTA02 Date of Testing : Jan. 04, 2008

More information

Specific Absorption Rate (SAR) Test Report for FIC (First International Computer, Inc.) on the Neo 1973

Specific Absorption Rate (SAR) Test Report for FIC (First International Computer, Inc.) on the Neo 1973 Specific Absorption Rate (SAR) Test Report for FIC (First International Computer, Inc.) on the Neo 1973 Report No. : EA721310-1-1-01 Trade Name : FIC Model No. : GTA01BV4 Date of Testing : May 29 and 30,

More information

SAR Distribution in Test Animals Exposed to RF Radiation

SAR Distribution in Test Animals Exposed to RF Radiation German Mobile Telecommunication Research Programme, July 25th, 2006 SAR Distribution in Test Animals Exposed to RF Radiation Verónica Berdiñas Torres, Andreas Christ, Niels Kuster IT IS Foundation, ETH

More information

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module Engineering Test Report No. 37802-02 Rev. A Measurement of RF Emissions from a Final Coat Electronics Corrosion Module For : Canadian Auto Preservation, Inc. 390 Bradwick Drive Concord, Ontario CANADA

More information

Mobile Phone SAR Analysis through Experimental and Numerical Simulation

Mobile Phone SAR Analysis through Experimental and Numerical Simulation 2010, 12th International Conference on Optimization of Electrical and Electronic Equipment, OPTIM 2010 Mobile Phone SAR Analysis through Experimental and Numerical Simulation Mihaela Morega 1, Andrei Marinescu

More information

RF Exposure and Modular Equipment. Considerations

RF Exposure and Modular Equipment. Considerations RF Exposure and Modular Equipment Considerations RF Exposure Rules SAR and MPE Estimation Summary Based on current interpretations of US radio law by FCC Based upon the TCB Exclusion List and various interpretations

More information

Assessment of Human Exposure to Electromagnetic Radiation from Wireless Devices in Home and Office Environments

Assessment of Human Exposure to Electromagnetic Radiation from Wireless Devices in Home and Office Environments Assessment of Human Exposure to Electromagnetic Radiation from Wireless Devices in Home and Office Environments Sven Kühn, Urs Lott, Axel Kramer, Niels Kuster Foundation for Research on Information Technologies

More information

SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES

SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES S.J. Porter, M.H. Capstick, F. Faraci, I.D. Flintoft and A.C. Marvin Department of Electronics, University of York Heslington, York, YO10 5DD,

More information

SAR TESTS ON MOBILE PHONES USED WITH AND WITHOUT PERSONAL HANDS-FREE KITS

SAR TESTS ON MOBILE PHONES USED WITH AND WITHOUT PERSONAL HANDS-FREE KITS SARTest Report 0083 July 2000 SAR TESTS ON MOBILE PHONES USED WITH AND WITHOUT PERSONAL HANDS-FREE KITS MI Manning and CHB Gabriel Report prepared for DTI. Page 1 of 17 Indemnity Sartest Limited makes

More information

IEC TC106. Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz

IEC TC106. Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz International Electrotechnical Commission IEC TC106 Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz R. C. Petersen Chairman Secretariat and

More information

IEEE 802.11 b/g/n WiFi Module. Product Specifications

IEEE 802.11 b/g/n WiFi Module. Product Specifications IEEE 802.11 b/g/n WiFi Module Product Specifications Model: S1 Version: 1.3 2010-12-27 Information in this document is subject to change without prior notice. Page 1 of 6 1. Introduction S1 is a WLAN module

More information

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS RF EXPOSURE LIMITS AND TESTING REQUIREMENTS Jay Moulton Vice President March 12, 2013 1 OVERVIEW Specific Absorption Rate (SAR) and Maximum Permissible Exposure (MPE) Standards and Limits Evaluation Methods

More information

R&D TESTING SAR EVALUATION

R&D TESTING SAR EVALUATION 802 N. Twin Oaks Valley Road, Suite 105 San Marcos, CA 92069 U.S.A. TEL (760) 471-2100 FAX (760) 471-2121 http://www.rfexposurelab.com R&D TESTING SAR EVALUATION Bodywell Chip Dates of Test: February 5,

More information

MoCA Adapter MC1001 v2 Installation Guide

MoCA Adapter MC1001 v2 Installation Guide Technical Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label of your product and use it to register your product at www.netgear.com/register.

More information

MAINTENANCE & ADJUSTMENT

MAINTENANCE & ADJUSTMENT MAINTENANCE & ADJUSTMENT Circuit Theory The concept of PLL system frequency synthesization is not of recent development, however, it has not been a long age since the digital theory has been couplet with

More information

Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields

Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Federal Communications Commission Office of Engineering & Technology Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Additional Information for Evaluating

More information

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02

More information

RICHARD T ELL ASSOCIATES,INC.

RICHARD T ELL ASSOCIATES,INC. RICHARD T ELL ASSOCIATES,INC. An Evaluation of Test Measurement Data Obtained on the KW-Gard RF Protective Suit March 30, 1998 Prepared for Euclid Garment Manufacturing Company 333 Martinel Drive Kent,

More information

Specific Absorption Rate (SAR) in the head of Tablet user's

Specific Absorption Rate (SAR) in the head of Tablet user's 7th Latin American Workshop On Communications - 2015 Specific Absorption Rate (SAR) in the head of Tablet user's Juliana Borges Ferreira Post-graduation program in Electrical Engineering Federal University

More information

Measurements of radiofrequency fields from a WEL Networks Smart Meter

Measurements of radiofrequency fields from a WEL Networks Smart Meter Measurements of radiofrequency fields from a WEL Networks Smart Meter Report 2012/36 This report was prepared for: WEL Networks Ltd P O Box 925 Hamilton Report prepared by: Martin Gledhill Finalised: 7

More information

CITY UNIVERSITY OF HONG KONG. A Study of Electromagnetic Radiation and Specific Absorption Rate of Mobile Phones with Fractional Human Head Models

CITY UNIVERSITY OF HONG KONG. A Study of Electromagnetic Radiation and Specific Absorption Rate of Mobile Phones with Fractional Human Head Models CITY UNIVERSITY OF HONG KONG A Study of Electromagnetic Radiation and Specific Absorption Rate of Mobile Phones with Fractional Human Head Models Submitted to Department of Electronic Engineering in Partial

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBAL SERVICES LTD Partial Test of: BTM411 To: EN 300 328 V1.7.1 (2006-10) Test Report Serial No: RFI/RPT1/RP76018JD01A This Test Report Is Issued Under The Authority Of Brian Watson, Operations

More information

Radiofrequency Exposure at Eye Plane of 6 Year Old Child Smartphone Placed In Cardboard Simulation Position

Radiofrequency Exposure at Eye Plane of 6 Year Old Child Smartphone Placed In Cardboard Simulation Position Radiofrequency Exposure at Eye Plane of 6 Year Old Child Smartphone Placed In Cardboard Simulation Position Smartphone placed in a position to the eyes as it would be placed using the cardboard virtual

More information

TCB RF Exposure Training

TCB RF Exposure Training TCB RF Exposure Training RF Exposure (RFx( RFx) ) Coming Attractions Goals for Exclusion List Handoff Exposure Categories and Considerations Collocated Devices Tim Harrington, FCC/OET/EAB February 13-15,

More information

Human exposure to RF

Human exposure to RF INTERNATIONAL ELECTROTECHNICAL COMMISSION Human exposure to RF Don Heirman ACEC/TC106 Liaison Representative APEMC symposium May 2015 Copyright IEC, Geneva, Switzerland TC106 Scope To prepare international

More information

The Aulterra Neutralizer Reduces the Intensity of Cell Phone Radiation

The Aulterra Neutralizer Reduces the Intensity of Cell Phone Radiation Executive Summary The Aulterra Neutralizer Reduces the Intensity of Cell Phone Radiation Cell phone radiation is harmful to the body. Higher doses produce stronger damaging effects. To protect the brain

More information

Exposures to radiofrequency fields from WiFi in New Zealand schools

Exposures to radiofrequency fields from WiFi in New Zealand schools Exposures to radiofrequency fields from WiFi in New Zealand schools Report 2014/02 This report was prepared for: Ministry of Health P O Box 5013 Wellington Report prepared by: Martin Gledhill Finalised:

More information

Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions

Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions M. R. Iqbal-Faruque* 1, N. Aisyah-Husni 2, Md. Ikbal-Hossain 1, M. Tariqul-Islam 2 and N. Misran 2 1

More information

Effect of Metallic Materials on SAR

Effect of Metallic Materials on SAR Contemporary Engineering Sciences, Vol. 5, 2012, no. 9, 407-411 Effect of Metallic Materials on SAR Asma Lak Department of Electrical Engineering, Genaveh branch Islamic Azad University, Genaveh, Iran

More information

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015 Report Of Shielding Effectiveness Test For SafeSleeve Radiation Shielding Technology Test Date(s): June 07 June 09, 2015 Issue Date: June 10, 2015 UST Project No: 15-0137 Total Number of Pages Contained

More information

NI USB-5681 RF Power Meter Specifications

NI USB-5681 RF Power Meter Specifications NI USB-568 RF Power Meter Specifications General This document lists specifications for the NI USB-568 RF power meter. Minimum or maximum specifications are warranted under the following conditions: hour

More information

Electromagnetic Compatibility Test Report Test results of Floww equipment

Electromagnetic Compatibility Test Report Test results of Floww equipment Electromagnetic Compatibility Test Report Test results of Floww equipment Reference number Status test report Brand Model number : 10C00357RPT01.doc : Final : Floww : mobilefloww screenfloww pocketfloww

More information

RR649. Assessment uncertainties relating to electromagnetic fields (EMF) measurement and computation

RR649. Assessment uncertainties relating to electromagnetic fields (EMF) measurement and computation Health and Safety Executive Assessment uncertainties relating to electromagnetic fields (EMF) measurement and computation Prepared by EMFields Limited for the Health and Safety Executive 2008 RR649 Research

More information

Broadband over Power Line (BPL) Test Procedures and Equipment Authorization

Broadband over Power Line (BPL) Test Procedures and Equipment Authorization Broadband over Power Line (BPL) Test Procedures and Equipment Authorization Andy Leimer Equipment Authorization Branch Federal Communications Commission Office of Engineering and Technology Laboratory

More information

FCC RF Exposure Report

FCC RF Exposure Report FCC RF Exposure Report FCC ID Equipment Model No. Brand Name Applicant : SQGBT800 : BTv4.0 Dual Mode USB Dongle : BT820 : Laird Technologies : Laird Technologies Address : 11160 Thompson Ave. / Lenexa,

More information

R&S ZNC Vector Network Analyzer Specifications

R&S ZNC Vector Network Analyzer Specifications ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement

More information

'Possibilities and Limitations in Software Defined Radio Design.

'Possibilities and Limitations in Software Defined Radio Design. 'Possibilities and Limitations in Software Defined Radio Design. or Die Eierlegende Wollmilchsau Peter E. Chadwick Chairman, ETSI ERM_TG30, co-ordinated by ETSI ERM_RM Software Defined Radio or the answer

More information

FDA Guidelines for Magnetic Resonance Equipment Safety

FDA Guidelines for Magnetic Resonance Equipment Safety FDA Guidelines for Magnetic Resonance Equipment Safety Loren A. Zaremba, Ph.D. Center for Devices and Radiological Health Food and Drug Administration Outline I. Introduction II. Static Magnetic Field

More information

Application Note: Spread Spectrum Oscillators Reduce EMI for High Speed Digital Systems

Application Note: Spread Spectrum Oscillators Reduce EMI for High Speed Digital Systems Application Note: Spread Spectrum Oscillators Reduce EMI for High Speed Digital Systems Introduction to Electro-magnetic Interference Design engineers seek to minimize harmful interference between components,

More information

Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz

Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity

More information

How To Know If You Are Safe To Use An Antenna (Wired) Or Wireless (Wireless)

How To Know If You Are Safe To Use An Antenna (Wired) Or Wireless (Wireless) 1 2 The range of RF spans 3 KHz (3000 Hz) to 300 GHz (300 million Hz) Frequencies of RF devices range from the low frequency AM broadcasts (80 MHz) to higher frequency mobile phones (1900 MHz) smart meters

More information

RF safety at base station sites

RF safety at base station sites RF safety at base station sites CONTENTS 1 Purpose and scope................................................. 2 2 Introduction........................................................ 2 3 Basic information...................................................

More information

VARIATION TO LICENCE AREA PLAN

VARIATION TO LICENCE AREA PLAN Attachment A VARIATION TO LICENCE AREA PLAN BRIDGETOWN (RADIO) May 2001 LICENCE AREA PLAN BRIDGETOWN VARIATION The Australian Broadcasting Authority hereby varies the licence area plan (LAP) for radio

More information

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING TESTING CERT #803.01, 803.02, 803.05, 803.06 MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING DATE OF

More information

Wireless. with Personal Mix Control and EP3 Dynamic Earphones

Wireless. with Personal Mix Control and EP3 Dynamic Earphones Wireless In-Ear Monitor Systems with Personal Mix Control and EP3 Dynamic Earphones Why In-Ear Monitors? Clarity is first among the many reasons to make the switch from traditional floor monitors to wireless

More information

1 USB Modem Introduction

1 USB Modem Introduction 1 USB Modem Introduction 1.1 Introduction Thank you for choosing the ZTE MF636 USB modem. Please read this manual carefully and keep it for future reference. The pictures, symbols and contents in this

More information

Introduction Ericsson Handheld Telephone 1341-B

Introduction Ericsson Handheld Telephone 1341-B Ericsson Handheld Telephone 1341-B 2 Contents General 5 The Mobile Telephone Network 6 Base Station and Cell 7 Radio Channels 7 Radio Coverage 8 Transmission Control and Communication 9 Quality Control

More information

ELECTRON SPIN RESONANCE Last Revised: July 2007

ELECTRON SPIN RESONANCE Last Revised: July 2007 QUESTION TO BE INVESTIGATED ELECTRON SPIN RESONANCE Last Revised: July 2007 How can we measure the Landé g factor for the free electron in DPPH as predicted by quantum mechanics? INTRODUCTION Electron

More information

GSMPBX version 1.3 Datasheet

GSMPBX version 1.3 Datasheet GSMPBX version.3 Datasheet Document Rev.:.3 Revision Date: 23.03.203 (preliminary data) Figure - GSMPBX Introduction The GSMPBX is designed to commute phone calls between a cellular network (GSM) and the

More information

Scanning with Sony Ericsson TEMS Phones. Technical Paper

Scanning with Sony Ericsson TEMS Phones. Technical Paper Scanning with Sony Ericsson TEMS Phones Technical Paper Scanning with Sony Ericsson TEMS Phones 2009-05-13 Ascom 2009. All rights reserved. TEMS is a trademark of Ascom. All other trademarks are the property

More information

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT For AeroComm, Inc. 10981 Eicher Drive Lenexa, KS 66219 2003-05-22 This Report Concerns: Original Report Equipment Type: 900MHz Transceiver Test Engineer:

More information

How To Use A Sound Card With A Subsonic Sound Card

How To Use A Sound Card With A Subsonic Sound Card !"## $#!%!"# &"#' ( "#' )*! #+ #,# "##!$ -+./0 1" 1! 2"# # -&1!"#" (2345-&1 #$6.7 -&89$## ' 6! #* #!"#" +" 1##6$ "#+# #-& :1# # $ #$#;1)+#1#+

More information

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec This value-packed VuSpec CD-ROM represents the most complete resource available for professional engineers looking for

More information

RF Measurements Using a Modular Digitizer

RF Measurements Using a Modular Digitizer RF Measurements Using a Modular Digitizer Modern modular digitizers, like the Spectrum M4i series PCIe digitizers, offer greater bandwidth and higher resolution at any given bandwidth than ever before.

More information

Test Report. DAB+ Automotive OEM Receiver. Nasjonal kommunikasjonsmyndighet Nygård 1, Postboks 93 4791 Lillesand, Norway

Test Report. DAB+ Automotive OEM Receiver. Nasjonal kommunikasjonsmyndighet Nygård 1, Postboks 93 4791 Lillesand, Norway Report No. 298328-3 Test Report Product Name and address of the applicant Name and address of the manufacturer DAB+ Automotive OEM Receiver Nasjonal kommunikasjonsmyndighet Nygård 1, Postboks 93 4791 Lillesand,

More information

SmartDiagnostics Application Note Wireless Interference

SmartDiagnostics Application Note Wireless Interference SmartDiagnostics Application Note Wireless Interference Publication Date: May 27, 2015 KCF Technologies, Inc. Background The SmartDiagnostics wireless network is an easy to install, end-to-end machine

More information

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI FOR MORE INFORMATION CALL 125 8880 or FROM A NON-TELSTRA PHONE, CALL 13 2200 AND SAY PRE-PAID VISIT telstra.com/ppmbb VISIT A TELSTRA STORE OR PARTNER GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI

More information

SITE RADIATION SURVEY

SITE RADIATION SURVEY SITE RADIATION SURVEY Site X, zzz Town XX XXXXXXX, XXXXXXX Site ID No: 12345 Dated: 29.09.2007 1 CONTENTS 1.0 SCOPE... 3 2.0 EQUIPMENT... 4 3.0 TRANSMITTERS... 5 4.0 FM Antenna Details... 7 6.0 GENERAL...

More information

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz Test & Measurement Data Sheet 02.00 R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz R&S R-Line Compact Test Chamber At a glance The R-Line

More information

WIRELESS INSTRUMENTATION TECHNOLOGY

WIRELESS INSTRUMENTATION TECHNOLOGY BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904

More information

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC 1106180 File reference No: 2011-07-18

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC 1106180 File reference No: 2011-07-18 Report No: FCC 1106180 File reference No: 2011-07-18 ISO/IEC17025Accredited Lab. Applicant: FUJIAN NAN AN BAOFENG ELECTRONICS CO., LTD Product: Model No: Trademark: Two Way Radio UV-3R BAOFENG Test Standards:

More information

Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields

Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Federal Communications Commission Office of Engineering & Technology Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Additional Information for Evaluating

More information

R&S ZNBT8 Vector Network Analyzer Specifications

R&S ZNBT8 Vector Network Analyzer Specifications ZNBT8_dat-sw_en_3606-9727-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNBT8 Vector Network Analyzer Specifications 20.05.2014 08:39:42 CONTENTS Definitions... 3 Measurement range... 4

More information

Field Calibration Software

Field Calibration Software SIGNAL HOUND Field Calibration Software User s Manual Version 1.1.0 7/8/2016 This information is being released into the public domain in accordance with the Export Administration Regulations 15 CFR 734

More information

EPS and Network Engineering

EPS and Network Engineering Introduction This application note explains the functions and applications of a powerful unique feature of the SeeGull EX and MX Scanning Receivers: the Enhanced Power Scan (EPS). Unlike standard tools,

More information

DAB1001. Wireless Digital Radio Interface. Installation & User Guide

DAB1001. Wireless Digital Radio Interface. Installation & User Guide DAB1001 Wireless Digital Radio Interface Installation & User Guide Contents Contents... 2 Introduction... 3 Contents of Package... 4 Installation... 5 Product Overview... 5 Installation Procedure... 5

More information

Summary of ICES TC34 Activities

Summary of ICES TC34 Activities ATTACHMENT 3 Summary of ICES TC34 Activities Wolfgang Kainz 1 and Mark Douglas 2 Co-Chairs of IEEE ICES TC34 1 Food and Drug Administration, Silver Spring, Maryland, USA 2 IT IS Foundation, Zurich, Switzerland

More information

Agilent PN 8753-1 RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note

Agilent PN 8753-1 RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note Agilent PN 8753-1 RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer Product Note 2 3 4 4 4 4 6 7 8 8 10 10 11 12 12 12 13 15 15 Introduction Table of contents Introduction

More information

FDTD Computation of Sar Distributions in Human Head for Mobile Phones V.Purushothaman, N.Vignesh, S.Vijayakumar

FDTD Computation of Sar Distributions in Human Head for Mobile Phones V.Purushothaman, N.Vignesh, S.Vijayakumar FDTD Computation of Sar Distributions in Human Head for Mobile Phones V.Purushothaman, N.Vignesh, S.Vijayakumar Veltech Engineering College, purushothamanece@gmail.com, Vicky.ganapathy@gmail.com,vijayeee333@gmail.com

More information

MANUAL FOR RX700 LR and NR

MANUAL FOR RX700 LR and NR MANUAL FOR RX700 LR and NR 2013, November 11 Revision/ updates Date, updates, and person Revision 1.2 03-12-2013, By Patrick M Affected pages, ETC ALL Content Revision/ updates... 1 Preface... 2 Technical

More information

Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements

Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements Jagadish Nadakuduti, Lin Lu, Paul Guckian Qualcomm Technologies,

More information

VDI Mixer/Amplifier/Multiplier Chains (MixAMCs)

VDI Mixer/Amplifier/Multiplier Chains (MixAMCs) VDI Mixer/Amplifier/Multiplier Chains (MixAMCs) VDI s MixAMCs provide high performance broadband downconversion and frequency extension of microwave spectrum analyzers into the THz range. Models are currently

More information

AM Radio Field Strength Measurements with Confidence November 2004

AM Radio Field Strength Measurements with Confidence November 2004 AM Radio Field Strength Measurements with Confidence November 2004 Understanding the AM Broadcast signal The AM Broadcast service in the United States and many other countries is implemented in 10 khz

More information

EXPOSURE INDICES IN RF EPIDEMIOLOGY

EXPOSURE INDICES IN RF EPIDEMIOLOGY EXPOSURE INDICES IN RF EPIDEMIOLOGY Paolo Vecchia National Institute of Health, Rome, Italy Advances in Biological effects and Dosimetry of Low Energy Electromagnetic Fields Erice, 28 March - 8 April 1981

More information

This document is available at HTTP://WWW.FALCOM.DE/. FAL-ANT-1. GSM/DCS/GPS antenna (with Fakra-SMB connectors) Description. Version 1.

This document is available at HTTP://WWW.FALCOM.DE/. FAL-ANT-1. GSM/DCS/GPS antenna (with Fakra-SMB connectors) Description. Version 1. This document is available at HTTP://WWW.FALCOM.DE/. FAL-ANT-1 GSM/DCS/GPS antenna (with Fakra-SMB connectors) Description Version 1.00 Contents 0 INTRODUCTION...3 0.1 GENERAL... 3 1 SECURITY...4 1.1 GENERAL...

More information