1 2010, 12th International Conference on Optimization of Electrical and Electronic Equipment, OPTIM 2010 Mobile Phone SAR Analysis through Experimental and Numerical Simulation Mihaela Morega 1, Andrei Marinescu 2, Alexandru Mihail Morega 1 1 University POLITEHNICA of Bucharest, Faculty of Electrical Engineering, Bucharest, Romania 2 Research, Development and Testing National Institute for Electrical Engineering (ICMET), Craiova, Romania mihaela@iem.pub.ro, amarin@icmet.ro, amm@iem.pub.ro Abstract - The opportunity for the research objectives and results presented in the paper was offered by the setup and certification of an electromagnetic compatibility laboratory, targeted on development and compliance testing of mobile communication devices, concerning their ability to provide safe working conditions to the user. The experiments are designed to assess the compliance of the emitted radiation level with the basic restrictions expressed in terms of the dosimetric estimate, i.e. the specific energy absorption rate, physical quantity widely known by its acronym, SAR. A numerical model, based on the implementation of the finite element method was designed in order to replicate, as good as possible, some experimental results. After validation, the numerical model is intended to become a flexible tool, useful for intensive dosimetric analysis, with objectives complementary to the experimental goals and possibilities. The paper introduces the experimental arrangement and the numerical model, both designed accordingly to the current testing standardization in the field. A comprehensive set of results gives data for the comparison between measurements and calculus, with the specific objective of the calibration and validation the numerical model, in conformity with the experimental setup. I. INTRODUCTION Certification of mobile communication devices, prior to placing them on the market, requires careful assessment testing, performed by accredited laboratory, specialized for the determination of the Specific energy Absorption Rate (SAR). Regarding the domestic market of mobile phones, the state is in the position to protect the safety and health of the citizens, in their position of consumers, according to EU Recommendation 1999/519/CE [1], which is also transposed into national legislation *. A specialized laboratory, fully equipped for SAR measurement in agreement to international standards [2-5], was recently opened as a high performance facility, authorized to perform conformity assessment tests regarding the electromagnetic emissions of cellular phone terminals [6] **. The conformity of the procedures and the precision of the measurements provided here, were certified * Directive of the Romanian Health Ministry no / 2006 for the approvement of the Norms for limiting exposure of the general public to electromagnetic fields from 0 Hz, up to 300 GHz ** Laboratory for SAR Evaluation and Certification of Mobile Phone Terminals ( at the Research, Development and Testing National Institute for Electrical Engineering (ICMET), Craiova, Romania by a successful Interlaboratory comparison with similar laboratories in Europe. The access to efficient experimental equipment designed for SAR measurement and the availability of commercial software for numerical analysis of high frequency electromagnetic radiation, does not, however, provide for an unconditional solution to the electromagnetic field (EMF) dosimetric problem. Not speaking here about the biological issues, the technical aspects only, by themselves, are complex and challenging [7]; the energy absorption in human tissue is highly dependent on several characteristics that have to be considered in the experimental and/or computational approach: * the anatomical domain characterized by shape, inner nonhomogeneous structure, relative position in relation with the radiation source, electric properties of the biological tissues (variable with the frequency, with the hydration level, variable in the living compared to nonliving state of the body and thus difficult to be determined by measurements); * the characteristics of the radiation source signal waveform and frequency band, emitted power, polarization of the electromagnetic emitted wave, continuity, antenna type and its positioning inside the hand-held device; * the physical aspects of defining the dosimetric quantities (i.e. SAR for the study presented here) the procedure of measurement and computation, the averaging techniques over space and time; * the ratification procedure - the dosimetric quantities determined on the spot (either experimentally or numerically) should be compared with reference specifications in guidelines and standards. Most of the mentioned technical aspects are already specified by international regulations: human exposure guidelines [1, 8, 9], standards of measurement equipment and standards for the conformity assessment of electric and electronic equipment [2-5]. The investigation program presented here points to the experience and know-how acquired by the research team, for setting in work a complex assembly dedicated to dosimetric analysis in the field of high frequency nonionizing electromagnetic radiation, with reference to the normative frame. The dosimetric analysis assembly combines, in a complementary manner, a sophisticated measurement equipment and a flexible numerical model /10/$26.00 '2010 IEEE 95

2 II. EXPERIMENTAL SAR LABORATORY 1. Nonionizing radiation dosimetry The specific absorption of energy (dw/dm) in a lossy dielectric material exposed to high frequency EMF is currently related to the increase in temperature (T) and it is usually quantified by the Specific energy Absorption Rate, defined as (d) SAR = d d t dw d T, or SAR = C d m d t =σe2 / ρ [ W/kg], (1) where d /dt denotes the rate of a certain physical quantity, E represents the rms value of the inner electric field strength; C, σ and ρ are the physical properties of the material: specific heat capacity, electric conductivity and mass density. SAR is also the quantity measured during the tests performed for the certification of electronic wireless equipment, because it is referred to as a basic restriction in international norms for limiting human exposure to microwaves [1, 8, 9]. Two limiting levels are specified: a lower value for the exposure averaged over the entire human body and a higher value applicable for the local exposure of a particular vulnerable area of the body (for example the head). It is supposed that the restricted SAR values are averaged over time and space, as Table 1 shows. TABLE I STIPULATION ON SAR IN INTERNATIONAL STANDARDS AND GUIDELINES Averaged whole body SAR Localized SAR (head and trunk) Averaging time Europe 2 W/kg averaged 0.08 W/kg [9] over 10 g of tissue 6 min. USA * 1.6 W/kg averaged 0.08 W/kg [8] over 1 g of tissue 30 min. * in 2005 was issued a revised version of [8] which is harmonized with [9]. Since it is harmful to measure SAR directly in the human body, the standard procedures make reference to the use of phantoms [3, 4] and state specific experimental protocols aimed to ensure the best compliance to reality. The referred normative, adapted to the mobile phones fabrication in different world region are not identical; they are however harmonized. The most important aspects are the requirements on the measuring method and on the measurement accuracy provided by the test system. A special characteristic of both standards resides in the explicit and detailed provision for the measurement uncertainty; the limit of the maximum permissible uncertainty is about 3dB. 2. SAR measurement laboratory The test equipment presented in Fig.1 includes the device under test (DUT), i.e. the cell phone, the positioning and scanning system for the DUT and for the electric field probe, the calibration systems for the probe and for the tissue simulating substance, the command and data processing system. The phantom used for mobile phones testing is the Specific Anthropomorphic Mannequin (SAM) [3, 4]. Fig 1. Block diagram of the equipment Phantom enclosure and the liquids simulating the head tissue or other human body tissues are subjected to some strict requirements; when the frequency band of the mobile phone is changed the liquid should be changed accordingly, due to the working frequency influence on its dielectric properties. The robot for field probe positioning must be able to scan the whole volume subjected to exposure with a view to achieving a three-dimensional measurement of SAR with a remarkable positioning accuracy of ±0,2 mm. The miniature field probes have a special construction and very high linearity. The electric field probe is of three axes type (3D) and it can scan the phantom volume from a minimum depth of 4mm, measured from its bottom. The system available for our research is the commercial COMOSAR Satimo test bench that works with the monitoring and data processing OPENSAR software; the whole measuring system operates in an electromagnetically shielded room [6]. Fig. 2 presents the experimental setup (left) and the phone-positioning device holding the cell phone near the SAM phantom (right). The laboratory for SAR dosimetry is designed to perform measurements for all types of mobile phones existing on the market: CDMA, GSM 900/1800, WCDMA, UMTS etc. covering a frequency band from 450 to 2450 MHz. 3. SAR measurement procedure The dielectric properties of the tissue equivalent liquids are measured prior to the SAR analysis, at constant temperature. Dielectric permittivity ε and electric conductivity σ should have precise values, i.e. within ± 5% tolerance with reference to the standard [3, 4]. A performance check is made before the targeted measurements on SAR, in order to verify that the system operates according to the technical specification. This is a preliminary SAR measurement, using a setup where the generated signal comes from a dipole antenna. The components and the procedure for performance checking are the same as those used for the compliance tests. The result shall be found within the limits ±10 % of the target value, determined during the system validation check. The output power and frequency are controlled using a base station simulator. 96

3 III. NUMERICAL MODEL FOR DOSIMETRIC ANALYSIS Fig. 2 Experimental setup in the laboratory for SAR measurements The test proceeds further on these steps, for each position of the DUT: a radio connection is established at maximum DUT power using the base station emulator; SAR values are measured on a grid of equidistant points, on a surface situated at constant distance from the inner phantom surface; SAR values are recorded at equidistant points into a cube; peak SAR averaged values are computed and compared against the standard basic restrictions (Table 1). The product is checked in the "cheek" and "tilt" positions (defined in standards according to Fig. 3), on the left and right sides of the phantom and it is tested at the frequencies of each emission band, in the requested testing conditions. In order to minimize measurements errors, the probe tip must not be in contact with the phantom inner surface. However, the highest local SAR values are at the inner surface of the phantom and they should be evaluated; an extrapolation method is thus applied [11]. The extrapolation is based on a fourth-order polynomial least-square fit of measured data. The local SAR values are extrapolated to the liquid surface with a 1 mm step. The measurements have to be performed over a limited time due to the operating time of the DUT battery. In order to reduce the measurement duration, the distance between measurement locations should be large. Reasonable values are between 5 and 8 mm. However, an accurate assessment of the peak SAR values averaged over 10g and 1g of tissue is obtained with a very fine resolution of the three-dimensional scan. Interpolation is further used to obtain the adequate resolution. The measured and extrapolated SAR values are interpolated on a 1 mm grid with a three-dimensional thin plate spline algorithm. A 3D computational model, based on the finite elements method (FEM) was designed for the study of microwaves penetration in the human head, when exposed in the near field produced by a mobile phone device. Previous analysis of different FEM numerical models, either based on simplified geometry or built through numerical reconstruction from CT scans [11, 12], led us to the head model used in this study. The model was carefully designed to mimic the adult human head, with normal size and realistic shape, comparable to SAM, as described by the document referred in [3]. Recent literature offers a variety of studies performed with anatomical realistic numerical models [10-13]; however, the multitude of the documented versions reveals an inconvenient dispersion in the choice of physical and numerical details, that makes the comparison and the synthesis of conclusions very difficult. These circumstances support our efforts to build and evaluate our own FEM model, similar to SAM configuration, which is designed to perform numerical tests, complementary to experimental dosimetry and certification protocols. The model, implemented and processed with a commercial finite element software package, has the main quality of being available and accessible regarding our resources. Its concept is flexible and open to adjustments toward the design of different radiation sources. 1. Description of the model Human head: The computational model is inspired by the human head anatomy. A 3D reconstruction from 2D tomographic slices, that conserves the general shape of the head was previously performed with the software package 3D Slicer [14], and was further adjusted in order to comply with the Specific Anthropomorphic Mannequin (SAM) [3, 4]. The numerical results are to be compared with the measurements; the head is consequently modeled with a homogeneous inner structure, with the same physical properties as the liquid used to fill the SAM phantom in the experiment, at the working frequency of MHz. The electric conductivity is σ head = 1.32 S/m, the dielectric constant is ε r,head = 39.9, and ρ head = 10 3 kg/m 3 represents the mass density. Fig. 4 shows the representations of the head: (a) presents a homogeneous head, reconstructed from CT scans [14], (b) is the homogeneous head in Comsol Multiphysics, ready for FEM computation [14, 16], while (c) presents the formal SAM phantom [3, 4], used in experimental certification tests. Fig. 3 Hand held phone in the cheek (left) and tilt (right) position [3, 4]. Fig. 4 Head models: (a) homogeneous head, reconstructed from CT scans [14] (LEFT) (b) homogeneous FEM model [14, 16] (MIDLE) (c) SAM phantom [3, 4] (RIGHT) 97

4 The outer ear (pinna) is also considered in the FEM model. Pinnae are simulated in the SAM model by solid lowconductive half discs ( σ pinna = S/m, ε r pinna 5), which act as ear spacers; they are centered on the external auditory canal where the reference point RE (ERP) is placed (see Fig. 4.c). Ear spacers are important to maintain the proper distance between the phone and the head and for the correct positioning of the phone, but the electric field is not commonly determined inside them. Several computational models have already considered pinna influence on the electric field distribution; it was found that peak SAR values in pinna could be slightly higher than in the head of SAM [12, 13] but SAR averaging in that small volume does not fully comply with the usual procedures [3, 4]; the issue of considering pinna tissue in peak averaged SAR evaluation is still a matter of debate. In our FEM model, the outer ears have the same shape, form, dimensions, position and properties as SAM s ear spacers; they serve exclusively for the better positioning of the hand-held phone and are not subjected to SAR estimate. Source model: The cell phone model simulates the device used in the experimental setup, as a rectangular case with the dimensions x 46.7 x 15.6 mm, made of a low conductive material with the electric properties ε r phone = 2.5 and σ phone = 0.04 S/m. A microstrip patch antenna, fed by a rectangular waveguide, was designed to work in the microwave frequency range GHz, and in our study it produces a continuous wave at GHz. The antenna is placed in the upper part of the phone-case; the radiating patch and the ground plane are printed on a circuit board with ε r pcb = 5.3. The antenna configuration (geometry and positioning) was fixed through an oriented trial and error technique, with the goal of finding a version that matches, as good as possible, the experimental results obtained with a certain cell phone model (the inner design of the cell phone was not fully accessible). The emitted power is always adjusted at the value of 1 W, regardless variations in the characteristic impedance due to the coupling between the antenna and the head. The results are thus always normalized to the source average power and they are easily scalable to other values of the power emitted by the cell phone. Both tilt and cheek positions of the phone [2, 3] are considered in this study (Fig. 3). EMF problem: We created a numerical 3D FEM model, implemented with COMSOL Multiphysics [16], RF module. The application mode harmonic propagation of electromagnetic waves, solved for E in complex numbers representation is applied for the study presented here. The general wave equation, in terms of electric field strength E 1 μ E ω 2 ε j σ ω E = 0, (2) is valid for the computational domain - head and handset - enclosed by a spherical PML (perfectly matched layer), designed to absorb the radiation as close to the head as possible, with minimal perturbation of the propagation process. In eq. (2) ω=2πf is the angular frequency, j = 1 and μ, ε, σ are the magnetic and electric properties of the subdomains (specified earlier); μ=μ 0 is the magnetic permeability of free space, same as for biological tissue. The microwaves source, placed at the feed-point of the antenna is implemented as a Port boundary condition, with the characteristics of the rectangular waveguide. 2. Numerical dosimetric estimate The currently applied standards [3] and [4] make clear specification of experimental settings and methods necessary to determine peak spatial-average SAR in human head. SAR is averaged over 1g and 10g of substance contained in a cube with the respective side length 10 mm and 21.5 mm. The cube should contain the region with maximal SAR values around the peak. The experimental averaging techniques are based on interpolation procedures, applied to several local measurements, performed at locations monitored by the positioning system of the field probe. The computation averaging techniques are highly dependent on the numerical method applied [5]. Since FDTD is widely used in high frequency EMF analysis [11, 12, 13], the recommended averaging numerical technique is based on the identification of an averaging cubic volume coherently adapted to the finite differences grid, or to the numerical implementation of the experimental procedure. Finite element modeling is just moderately expanded in nowadays high frequency electromagnetic analysis, mainly due to historical evolution. The precise identification of the averaging volume requires its prior definition as a distinct subdomain in the geometry of the model. This is possible through repetitive intervention in the model description, based on the analysis of the solution. The technique is time consuming and particularly dependent on any change in the description of the model; however, this technique was applied in the study presented here. Another approach is (same as for FDTD method) the numerical implementation of the experimental technique; this path is intended to further extend the dimension of our study. 3. The accuracy of the model Before advancing to the stage of performing numerical tests consistent with the experiment, the numerical model passed some accuracy tests. The set of numerical tests took into account two accuracy objectives, focused on getting a trustful solution: (1) how far should the PML be positioned with reference to the radiation source, (2) how small should the mesh size be chosen. Both objectives were addressed through a trial and error approach, taking the satisfactory precision of the solution, as the accuracy criterion; several post processing global quantities were analyzed: the emitted power, the power absorbed in the head, SAR averaged over 1g and 10g of tissue, the power passing through the PML, the energy balance on the domain. 98

5 4. Comparative evaluation of exposure conditions The numerical model was designed to simulate as close as possible the experimental conditions [17]: the head model is a digitized replica of the SAM phantom same shape, homogeneous structure, same physical properties of the simulant tissue, and both, cheek and tilt positions of the phone, comply with the standards [3, 4]; the phone under test is a commercially widely available cell phone model [18]; it is replicated in the numerical model by its size and it works at the same characteristic frequency ( MHz) and the same emitted average power 1 W; the experiment is performed at the maximum working power of the phone, which was previously determined to be 30dBm, i.e. 1 W. However, several dissimilarities have to be emphasized, because they justify the major uncertainties of the simulation: the inner structure of the cell phone is not fully known; consequently, one of the main unknowns of the numerical simulation was the precise design and positioning of the microwave antenna; we have tried several versions and the best choice is adopted here and support the results presented later; the radiation source in the experiment emitted a time division multiple access (TDMA) signal, while the numerical simulation focused only on the continuous wave (CW) signal (at the same frequency and power); the distance to the head was carefully checked but it is not sure that it was always replicated; the numerical FEM model does not account for the phantom s shell, fabricated as a 2 mm thick, nonconductive material; however, the ear spacers ensure the proper position of the phone and the minimal distance to the head. position), sliced at 4-5 mm distance from that surface. The distance could be slightly different in the two settings; however, the experimental result (Fig. 5a) and the numerical one (Fig. 5b) are in good agreement, considering the dissimilarities stressed earlier. Fig. 6 a and b evidence the results obtained in similar conditions of exposure and dosimetric estimate, while the phone device is held in the tilt position. Another type of analysis applied to SAR distribution is provided by the linear scans of the same quantity in a direction perpendicular to the section plane considered in Figs. 5 and 6; this is the direction of maximal in-depth penetration of absorbed power. Fig. 7 shows the in-depth experimental and computed SAR graphs in the already considered (a) cheek and (b) tilt positions. a. Experimental SAR distribution IV. RESULTS The comparative, experimental vs. computational study was directed toward a double objective: the validation through measurement of a FEM numerical model concept and the exploratory analysis seeking aspects of complementarity and added value, between experimental and computational approaches. The same category of data acquisition was performed, both on the experimental test bench and through the numerical simulation: (1) local SAR distribution inside a head exposed to the high frequency EMF radiation coming from a cell phone device mounted near the ear and (2) averaged peak SAR over 1g and 10g of tissue. 1. SAR distribution analysis The primary solution of both measurement and simulation is the electric field strength distribution inside the exposed head. The E-field solution is numerically post-processed in both approaches, and the target output quantity, SAR is computed (1). Fig. 5 shows the SAR spectra in a cut-plane parallel to the surface of the phone device (in the cheek b. SAR distribution on the numerical model Fig. 5 SAR spectra in plane sections through the highest exposed head region; emitted power - 1W; phone in the cheek position 99

6 a. Experimental SAR distribution a. The phone in the cheek position b. The phone in the tilt position Fig. 7 Measured and computed SAR scans following the in-depth direction of maximal values; emitted power - 1W b. SAR distribution on the numerical model Fig. 6 SAR spectra in plane sections through the highest exposed head region; emitted power - 1W; phone in the tilt position 2. Peak SAR averaged over 1g and 10g After locating the SAR spot, which is at the surface of the head (closest from the radiation source), the probe positioning system could scan and evaluate local E-field values, in the nodes of a 5 mm resolution spatial grid. The rest is computation interpolation between nodes and extrapolation toward the phantom shell and numerical estimate of averaged SAR values (earlier described in II.3). The FEM method provides for a fine adjustment of the geometry. A precise description of geometric shapes close to cubes is possible by choosing the exterior face of the cubes coincident with, or tangent to the head surface enclosing the SAR spot; two methods for identification of cubic adequate volumes are described in [2]. The FEM software gives the possibility to numerically integrate SAR on any previously identified subdomain. Table 2 contains the peak SAR values determined from measurements and from numerical EMF analysis, as averaged over 1g and 10g of head tissue, for the cheek and tilt positions of the cell phone held close to the head. TABLE 2 COMPARATIVE ANALYSIS BETWEEN EXPERIMENTAL AND COMPUTED PEAK AVERAGED SAR VALUES Averaged SAR cheek position tilt position [W/kg] experim. comput. experim. comput. over 1 g over 10 g The relative errors between measured and computed values are within ±10%. 3. Uncertainty analysis and possible error sources The precision of the measurement system and the calibration data available for its components makes possible the precise quantitative estimate of the measuring uncertainty; each conformity test is documented by a test report, which includes an estimate the uncertainties [17]. SAR values generally obtained by experimental simulation with COMOSAR system are affected by a measurement uncertainty of ±3dB. However, a typical value for the 100

7 simulations usually performed in our experiments and presented here is about ±1.5dB. The precision of the experimental results was already checked and confirmed through the interlaboratory comparison procedure [3, 17]. The numerical model introduced and tested in our research was designed and optimized to become a trustful tool for analysis, working together with the experimental setting. The results presented here confirm its validity in the numerical aspects and its flexibility to comply with technical aspects and normative frame. Some susceptible error sources in the design of the model are discussed further. The characteristics of the microwave source have a decisive impact on local SAR distribution and peak values. The antenna type, dimensions and position (inside the phone and relative to the head, particularly the feed point positioning and wave polarization) are of major significance. The signal waveform is less important, as long as the average power transported at the characteristic frequency is the same. CW and TDMA signals at the same average power and characteristic frequency were found to lead to similar SAR distributions. The distance between the EMF source and the surface of the body determines the in-depth penetration of the E- field and SAR distribution; when different models are compared, the proper estimate of that distance should be considered. In our case, better information on the inner design of the cell phone is necessary. The averaging technique for the peak SAR values is another source of errors; it depends on the numerical method and on the space grid. V. COMMENTS, CONCLUSIONS AND FURTHER RESEARCH The research objectives and results presented in the paper address a quantitative correspondence between different simulation tools applied in SAR dosimetry, related to the compliance testing of mobile phones. An experimental setup, which recently became functional, was certified through the interlaboratory comparison procedure. The information on the test bench and measurements was applied to the design and validation of a numerical FEM model that mimics the experimental setting. In the dosimetric evaluation of EMF penetration in tissue exposed to microwaves, the E and SAR distributions are usually determined. Standardization bodies have already agreed on the settings of experimental conditions and protocols for the certification of hand held wireless communication devices [2-5], but computational protocols are still under debate; Technical Committee TC34 of the IEEE International Committee on Electromagnetic Safety is the standardization body currently working on that task. The advantages of the numerical modeling compared with experimental measurements are obvious: rapidity in evaluation, repeatability of results and versatility of the models at lower costs. The FEM model introduced and evaluated here is intended to offer complementary information to experimental tests. Once the mathematical model is functional and validated, the experimental measurements could be restricted to a minimal set, which is necessary for the calibration of the numerical model; the computational outputs could further be diversified and multiplied without the restrictions and uncertainties that always limit an experiment. The proper combination of measurement and computation leads to an optimized testing setting, characterized by minimal uncertainties and costs. Further research will concentrate on several tasks: the equivalence among different numerical interpolation procedures and averaging techniques for the computation of the dosimetric quantities with better precision and in agreement with experimental techniques; the quantitative analysis of the uncertainties in the computational procedure; the study of sensitivities applied to the experimental and numerical models, due to the dispersion of certain physical factors, i.e. the temperature, the dielectric properties, etc.; the work on the phone model - a collection of models including different types of cell phones and a more detailed representation of the device (including the battery and the electronic printed circuit board). ACKNOWLEDGMENT The authors are grateful to Dr. Jerome Luc from SATIMO for his valuable assistance at setting into service the SAR measurement Laboratory. The authors would also like to thank to their colleagues: Dipl.-Ing. I. Dumbrava, Dipl.-Ing. G. Mihai and Dipl.-Ing. C. Vargatu from ICMET Craiova for their participation at the experimental program. The research benefited from the access to the infrastructure and resources financed by the Romanian Research Authority ANCS through the contract no.79/2007 (PNCDI_II, Capacitati Program) and the grant no.54/2006 BIOINGTEH (CNCSIS, Interdisciplinary Platform Program). REFERENCES [1] Council of the European Union, Council Recommendation of 12 July 1999 on the Limitation of Exposure of the General Public to Electromagnetic Fields (0 Hz to 300 GHz), Official Journal of the European Communities L199/519/EC, 59-70, 1999 [2] EN 50360:2001 Product Standard to Demonstrate the Compliance of Mobile Phones with the Basic Restrictions Related to Human Exposure to Electromagnetic Fields (300 MHz - 3 GHz), IEC Standard, 2001 [3] EN :2005 Human Exposure to Radio Frequency Fields from Hand-Held and Body-Mounted Wireless Communication Devices Human Models, Instrumentation and Procedures Part 1: Procedure to Determine the Specific Absorption Rate (SAR) for Hand-Held Devices Used in Close Proximity to the Ear (Frequency Range of 300 MHz to 3 GHz), IEC Standard, [4] IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques, IEEE Standard, 2003 [5] C IEEE Recommended Practice for Measurements and Computations of Radio Frequency Electromagnetic Fields with Respect 101

8 to Human Exposure to Such Fields, 100 khz 300 GHz, IEEE Standard, 2002 [6] A. Marinescu, The First Romanian SAR Measurement Facility, ACER Bulletin ISSN , vol. 16, 2008, p. 3-8 [7] N. Kuster, Q. Balzano, J. Lin (Editors): Mobile Communications Safety, Chapman&Hall, London, 1993 [8] C IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 khz to 300 GHz, IEEE Standard, 1991 (revised version 2005) [9] ICNIRP, Guidelines for limiting exposure to time-varying electric, magnetic and electromagnetic fields (up to 300 GHz), Health Phys., vol. 74, 1998, pp [10] M. Brishoual, C. Dale, J. Wiart, and J. Citerne, Methodology to interpolate and extrapolate SAR measurements in a volume in dosimetric experiments, IEEE Trans. on EMC, vol. 43, n 3, pp , [11] B. B. Beard, et al. Comparisons of Computed Mobile Phone Induced SAR in the SAM Phantom to That in Anatomically Correct Models of the Human Head, IEEE Trans. on EMC, vol. 48, pp , 2006 [12] W. Kainz, et al. Dosimetric comparison of the specific anthropomorphic mannequin (SAM) to 14 anatomical head models using a novel definition for the mobile phone positioning, Phys. Med. Biol., vol. 50, pp , 2005 [13] B. B. Beard, W. Kainz W, Review and standardization of cell phone exposure calculations using the SAM phantom and anatomically correct head models, Biomed Eng Online, doi: / X-3-34, 2004 [14] M. Morega, A. M. Morega, A. Machedon, 3D FEM model for localized SAR estimate in human exposure to microwaves, Proc. of the 7th EMC Europe Intl Symp. on Electromagnetic Compatibility, Barcelona, Spain, 2006, ISBN: , p [15] M. Morega, A. M. Morega, A. Machedon, Analysis of several FEM Models for the Assessment of the Human Head Exposure to Microwaves, Intl. Conf. MediTech, Cluj-Napoca, Romania, 2009, Springer Series: IFMBE Proceedings, Vol. 26, ISBN: , ISSN: , p [16] Comsol Multiphysics 3.5a, User's Guide and Modeling Guide, Copyright by COMSOL AB. [17] ICMET Craiova, Department Laboratories - High Voltage Division, HVD Laboratory for SAR evaluation, Test Report No.15/June 2009 [18] GSM Arena info: 102

Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions

Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions M. R. Iqbal-Faruque* 1, N. Aisyah-Husni 2, Md. Ikbal-Hossain 1, M. Tariqul-Islam 2 and N. Misran 2 1

More information

THE FIRST ROMANIAN SAR MEASUREMENT FACILITY WILL BE OPERATIONAL IN 2009

THE FIRST ROMANIAN SAR MEASUREMENT FACILITY WILL BE OPERATIONAL IN 2009 THE FIRST ROMANIAN SAR MEASUREMENT FACILITY WILL BE OPERATIONAL IN 2009 ANDREI MARINESCU Key words: SAR. Abstract The mobile telephony is the most important discovery ever from the viewpoint of the impact

More information

Specific Absorption Rate (SAR) in the head of Tablet user's

Specific Absorption Rate (SAR) in the head of Tablet user's 7th Latin American Workshop On Communications - 2015 Specific Absorption Rate (SAR) in the head of Tablet user's Juliana Borges Ferreira Post-graduation program in Electrical Engineering Federal University

More information

For many years the general public

For many years the general public David Seabury, ETS-Lindgren An Update On SAR Standards And The Basic Requirements For SAR Assessment For many years the general public has been concerned about the possible health effects of exposure to

More information

How To Understand The Safety Of A Cell Phone (Cell Phone)

How To Understand The Safety Of A Cell Phone (Cell Phone) Compliance Testing of Mobile Phones Masao Taki Tokyo Metropolitan University JAPAN Outline Exposure Standards/Guidelines Product Standard of MTE and Standard Procedures of Compliance Testing Some remarks

More information

September 26, 2000 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort

September 26, 2000 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort TTI-P-G 158 Report Dosimetric Assessment of the Mobile Ericsson T18z with an without the PAM System Technologies devices According to the American FCC Requirements September 26, 2000 IMST GmbH Carl-Friedrich-Gauß-Str.

More information

Specific Absorption Rate (SAR) Induced in Human Heads of Various Sizes When Using a Mobile Phone

Specific Absorption Rate (SAR) Induced in Human Heads of Various Sizes When Using a Mobile Phone , June 30 - July 2, 2010, London, U.K. Specific Absorption Rate (SAR) Induced in Human Heads of Various Sizes When Using a Mobile Phone Adel Z. El Dein Alaeddin Amr Abstract - This paper analyzes the specific

More information

Human exposure to RF

Human exposure to RF INTERNATIONAL ELECTROTECHNICAL COMMISSION Human exposure to RF Don Heirman ACEC/TC106 Liaison Representative APEMC symposium May 2015 Copyright IEC, Geneva, Switzerland TC106 Scope To prepare international

More information

Effects of Cell Phone Radiation on the Head. BEE 4530 Computer-Aided Engineering: Applications to Biomedical Processes

Effects of Cell Phone Radiation on the Head. BEE 4530 Computer-Aided Engineering: Applications to Biomedical Processes Effects of Cell Phone Radiation on the Head BEE 4530 Computer-Aided Engineering: Applications to Biomedical Processes Group 3 Angela Cai Youjin Cho Mytien Nguyen Praveen Polamraju Table of Contents I.

More information

Thermal Effects of Mobile Phones

Thermal Effects of Mobile Phones Thermal Effects of Mobile Phones S. Kassimi 1, A. ELfadl, S. Bri 3, A. Nakheli 4, M. Habibi 5, M. Ben Ahmed 6 Systems and Telecommunications Engineering Decision Laboratory,Ibn Tofail University, Faculty

More information

ARIB TR-T12-34.925 V3.0.0. Specific Absorption Rate (SAR) requirements and regulations in different regions

ARIB TR-T12-34.925 V3.0.0. Specific Absorption Rate (SAR) requirements and regulations in different regions ARIB TR-T12-34.925 V3.0.0 Specific Absorption Rate (SAR) requirements and regulations in different regions Refer to "Notice" in the preface of ARIB TR-T12 for Copyrights. Technical Report 3rd Generation

More information

Body SAR and EU. B. Derat

Body SAR and EU. B. Derat Body SAR and EU B. Derat Overview / Outline New Approach: Directive / Standards Current applicable standard IEC/EN 62209-2:2010 Tablet case study Future of EU body SAR testing Maintenance of IEC 62209-2

More information

Human Exposure Limits

Human Exposure Limits Human Exposure Limits Session 3 0 Version December 2014 Learning objectives In this session we will: Learn about the international exposure limits for workers and the public Learn about methods for assessing

More information

SAMSUNG GT-S5369 (mobile phone) Serial number: IMEI 358858043716587. Mr. Antoine SAMAKH and Mr. Mathieu SAMAKH 92100 FRANCE

SAMSUNG GT-S5369 (mobile phone) Serial number: IMEI 358858043716587. Mr. Antoine SAMAKH and Mr. Mathieu SAMAKH 92100 FRANCE R052-DAS-12-104374-7/A Ed. 1 This report cancels and replaces the test report R052-DAS-12-104374-7/A Ed. 0 SAR TEST REPORT According to the standard: EN 62209-1: 2006 Equipment under test: Antenna patch

More information

IEC TC106. Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz

IEC TC106. Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz International Electrotechnical Commission IEC TC106 Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz R. C. Petersen Chairman Secretariat and

More information

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz J. Klima, R. Ščehovič Department of Physics, Faculty of Natural Sciences, University of Mathias Bel, Tajovského

More information

AN OVERVIEW OF STANDARDS AND REGULATION CONCERNING EXPOSURE TO RADIOFREQUENCY FIELDS

AN OVERVIEW OF STANDARDS AND REGULATION CONCERNING EXPOSURE TO RADIOFREQUENCY FIELDS AN OVERVIEW OF STANDARDS AND REGULATION CONCERNING EXPOSURE TO RADIOFREQUENCY FIELDS Annamaria PALJANOS, paljanosanna@yahoo.com Călin MUNTEANU calin.munteanu@et.utcluj.ro TECHNICAL UNIVERSITY CLUJ NAPOCA,

More information

SAR Test Report: Type Number FAD-3022012-BV; FCC ID PY7FD022012; IC 4170B-FD022012

SAR Test Report: Type Number FAD-3022012-BV; FCC ID PY7FD022012; IC 4170B-FD022012 1 (34) Report issued by an Accredited Laboratory Rapport utfärdad av ett ackrediterat laboratorium This laboratory is accredited to SS-EN ISO/IEC 17025 (SWEDAC accreditation no. 1761). SAR Test Report:

More information

Human Exposure to Outdoor PLC System

Human Exposure to Outdoor PLC System 1602 PIERS Proceedings, Marrakesh, MOROCCO, March 20 23, 2011 Human Exposure to Outdoor PLC System Vicko Doric 1, Dragan Poljak 1, and Khalil El Khamlichi Drissi 2 1 University of Split, Croatia 2 Blaise

More information

Consequence for a dualband application

Consequence for a dualband application rel. bandwidth -6dB [%] DESIGN CONSIDERATIONS FOR INTEGRATED MOBILE PHONE ANTENNAS D. Manteuffel, A. Bahr, D. Heberling, I. Wolff IMST GmbH, Germany, e-mail: manteuffel@imst.de Abstract Based on the investigation

More information

Effect of Metallic Materials on SAR

Effect of Metallic Materials on SAR Contemporary Engineering Sciences, Vol. 5, 2012, no. 9, 407-411 Effect of Metallic Materials on SAR Asma Lak Department of Electrical Engineering, Genaveh branch Islamic Azad University, Genaveh, Iran

More information

La simulation en CEM et Hyperfréquences IEEE P1528.3 CAD interlaboratory comparison

La simulation en CEM et Hyperfréquences IEEE P1528.3 CAD interlaboratory comparison La simulation en CEM et Hyperfréquences IEEE P1528.3 CAD interlaboratory comparison Vikass Monebhurrun vikass.monebhurrun@supelec.fr Contributors: Yannis Braux (CST France), Mikhail Kozlov (Max Planck

More information

Simulation of Mobile Phone Antenna Performance

Simulation of Mobile Phone Antenna Performance Tough technical requirements are being put on handsets. Mobile phones have to deal with an ever increasing number of services, while at the same time the cost of the systems is being reduced. RD in the

More information

Low SAR planar antenna for multi standard cellular phones

Low SAR planar antenna for multi standard cellular phones Eur. Phys. J. Appl. Phys. 53, 33604 (011) DOI: 10.1051/epjap/010100064 Regular Article THE EUROPEAN PHYSICAL JOURNAL APPLIED PHYSICS Low SAR planar antenna for multi standard cellular phones M. Ben Ahmed

More information

Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands)

Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) Issue 3 June 2009 Spectrum Management and Telecommunications Radio Standards Specification Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) Aussi disponible

More information

FDTD Computation of Sar Distributions in Human Head for Mobile Phones V.Purushothaman, N.Vignesh, S.Vijayakumar

FDTD Computation of Sar Distributions in Human Head for Mobile Phones V.Purushothaman, N.Vignesh, S.Vijayakumar FDTD Computation of Sar Distributions in Human Head for Mobile Phones V.Purushothaman, N.Vignesh, S.Vijayakumar Veltech Engineering College, purushothamanece@gmail.com, Vicky.ganapathy@gmail.com,vijayeee333@gmail.com

More information

Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements

Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements Jagadish Nadakuduti, Lin Lu, Paul Guckian Qualcomm Technologies,

More information

Millennium Product Inc. Model: Cell Shield / Zorb

Millennium Product Inc. Model: Cell Shield / Zorb Millennium Product Inc. Cell Shield / Zorb Prepared by PCTEST LAB Issued on: 10/22/2015 Report Version 2.6 NOTE: SAR results only apply to the device tested. Although the device may have had different

More information

Wireless Broadband: Health & Safety Information

Wireless Broadband: Health & Safety Information Wireless Broadband: Health & Safety Information Introduction The increasing use of mobile phones and other wireless technology has been accompanied by public debate about possible adverse effects on health.

More information

MUCH work has been reported on determining the specific

MUCH work has been reported on determining the specific IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, VOL. 46, NO. 8, AUGUST 1999 911 Heating of Tissue by Near-Field Exposure to a Dipole: A Model Analysis Pere J. Riu, Senior Member, IEEE, and Kenneth R. Foster,*

More information

Implications for SAR when. using a symmetric phantom exposed to RF radiation using the FDTD method. Loughborough University Institutional Repository

Implications for SAR when. using a symmetric phantom exposed to RF radiation using the FDTD method. Loughborough University Institutional Repository Loughborough University Institutional Repository Implications for SAR when using a symmetric phantom exposed to RF radiation using the FDTD method This item was submitted to Loughborough University's Institutional

More information

SAR TEST REPORT. According to the standard: EN 62209-1: 2006

SAR TEST REPORT. According to the standard: EN 62209-1: 2006 R052-DAS-12-104374-2/A Ed. 1 This report cancels and replaces the test report R052-DAS-12-104374-2/A Ed. 0 SAR TEST REPORT According to the standard: EN 62209-1: 2006 Equipment under test: Antenna patch

More information

Electromagnetic Field Safety

Electromagnetic Field Safety SAR A Basic Restriction for Electromagnetic Field Safety David Baron, PE Consulting Engineer Electromagnetic Field Safety d.baron@ieee.org NOTE. CENAM is not responsible for the content of this document.

More information

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS RF EXPOSURE LIMITS AND TESTING REQUIREMENTS Jay Moulton Vice President March 12, 2013 1 OVERVIEW Specific Absorption Rate (SAR) and Maximum Permissible Exposure (MPE) Standards and Limits Evaluation Methods

More information

Real-life Applications of ICNIRP Guidelines to Various Human EMF Exposure Issues

Real-life Applications of ICNIRP Guidelines to Various Human EMF Exposure Issues Technical Forum Overview and Latest Development of Standards in Human Exposure to Electromagnetic Fields (EMF) Real-life Applications of ICNIRP Guidelines to Various Human EMF Exposure Issues Dr. Brian

More information

Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields

Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Federal Communications Commission Office of Engineering & Technology Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Additional Information for Evaluating

More information

Exposure Assessment of a High-Resonance Wireless Power Transfer System under the Misaligned Condition

Exposure Assessment of a High-Resonance Wireless Power Transfer System under the Misaligned Condition , pp.11-15 http://dx.doi.org/10.14257/astl.2015.116.03 Exposure Assessment of a High-Resonance Wireless Power Transfer System under the Misaligned Condition SangWook Park 1, ByeongWoo Kim 2, BeomJin Choi

More information

EXPOSURE INDICES IN RF EPIDEMIOLOGY

EXPOSURE INDICES IN RF EPIDEMIOLOGY EXPOSURE INDICES IN RF EPIDEMIOLOGY Paolo Vecchia National Institute of Health, Rome, Italy Advances in Biological effects and Dosimetry of Low Energy Electromagnetic Fields Erice, 28 March - 8 April 1981

More information

Numerical Computation of the Combined Specific Absorption Rates Induced in Human Head due to Multiple Independent Sources

Numerical Computation of the Combined Specific Absorption Rates Induced in Human Head due to Multiple Independent Sources International Journal of Electromagnetics and Applications 2015, 5(2): 73-79 DOI: 10.5923/j.ijea.20150502.01 Numerical Computation of the Combined Specific Absorption Rates Induced in Human Head due to

More information

SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES

SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES S.J. Porter, M.H. Capstick, F. Faraci, I.D. Flintoft and A.C. Marvin Department of Electronics, University of York Heslington, York, YO10 5DD,

More information

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Craig W. Fanning Elite Electronic Engineering, Inc. 1516 Centre Circle Downers

More information

Assessment of SAR in a human exposed to GSM electromagnetic fields

Assessment of SAR in a human exposed to GSM electromagnetic fields Assessment of SAR in a human exposed to GSM LUAN AHMA, MIMOZA IBRANI, ENVER HAMITI Faculty of Electrical and Computer Engineering University of Prishtina Bregu i Diellit, nn KOSOVO luan.ahma@fiek.uni-pr.edu

More information

Federal Communications Commission Office of Engineering and Technology Laboratory Division Public Draft Review

Federal Communications Commission Office of Engineering and Technology Laboratory Division Public Draft Review April 23, 2012 Federal Communications Commission Office of Engineering and Technology Laboratory Division Public Draft Review Draft Laboratory Division Publications Report Title: General RF Exposure Policies

More information

Federal Communications Commission Office of Engineering and Technology Laboratory Division

Federal Communications Commission Office of Engineering and Technology Laboratory Division October 24, 2012 Federal Communications Commission Office of Engineering and Technology Laboratory Division Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies Table

More information

Wideband Dual Segment Rectangular Dielectric Resonator Antenna Terminate in Bio-Media

Wideband Dual Segment Rectangular Dielectric Resonator Antenna Terminate in Bio-Media Wideband Dual Segment Rectangular Dielectric Resonator Antenna Terminate in Bio-Media Ravi Kumar Gangwar, S. P. Singh and D. Kumar Abstract In this paper a wideband dual segment rectangular dielectric

More information

1 Introduction. JS'12, Cnam Paris, 3-4 Avril 2012. Ourouk Jawad 1, David Lautru 2, Jean Michel Dricot, François Horlin, Philippe De Doncker 3

1 Introduction. JS'12, Cnam Paris, 3-4 Avril 2012. Ourouk Jawad 1, David Lautru 2, Jean Michel Dricot, François Horlin, Philippe De Doncker 3 Statistical Study of SAR under Wireless Channel Exposure in Indoor Environment Etude Statistique du DAS sous Exposition d un Canal sans Fils en Environnement Intérieur Ourouk Jawad 1, David Lautru 2, Jean

More information

SAR Distribution in Test Animals Exposed to RF Radiation

SAR Distribution in Test Animals Exposed to RF Radiation German Mobile Telecommunication Research Programme, July 25th, 2006 SAR Distribution in Test Animals Exposed to RF Radiation Verónica Berdiñas Torres, Andreas Christ, Niels Kuster IT IS Foundation, ETH

More information

Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields

Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Federal Communications Commission Office of Engineering & Technology Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Additional Information for Evaluating

More information

Safakcan Tuncdemir 1, William M. Bradley *2. 1. Introduction

Safakcan Tuncdemir 1, William M. Bradley *2. 1. Introduction Modeling and Experimental Verification of the Power Transfer and Thermal Characteristics of Piezoelectric Transformers Subjected to Combined Mechanical and Electrical Loading Safakcan Tuncdemir 1, William

More information

RF EXPOSURE PROCEDURES AND EQUIPMENT AUTHORIZATION POLICIES FOR MOBILE AND PORTABLE DEVICES

RF EXPOSURE PROCEDURES AND EQUIPMENT AUTHORIZATION POLICIES FOR MOBILE AND PORTABLE DEVICES Federal Communications Commission Office of Engineering and Technology Laboratory Division October 23, 2015 RF EXPOSURE PROCEDURES AND EQUIPMENT AUTHORIZATION POLICIES FOR MOBILE AND PORTABLE DEVICES Table

More information

CITY UNIVERSITY OF HONG KONG. A Study of Electromagnetic Radiation and Specific Absorption Rate of Mobile Phones with Fractional Human Head Models

CITY UNIVERSITY OF HONG KONG. A Study of Electromagnetic Radiation and Specific Absorption Rate of Mobile Phones with Fractional Human Head Models CITY UNIVERSITY OF HONG KONG A Study of Electromagnetic Radiation and Specific Absorption Rate of Mobile Phones with Fractional Human Head Models Submitted to Department of Electronic Engineering in Partial

More information

Summary of ICES TC34 Activities

Summary of ICES TC34 Activities ATTACHMENT 3 Summary of ICES TC34 Activities Wolfgang Kainz 1 and Mark Douglas 2 Co-Chairs of IEEE ICES TC34 1 Food and Drug Administration, Silver Spring, Maryland, USA 2 IT IS Foundation, Zurich, Switzerland

More information

An Efficient Finite Element Analysis on an RF Structure Used to Evaluate the Effect of Microwave Radiation on Uveal Melanoma Cells

An Efficient Finite Element Analysis on an RF Structure Used to Evaluate the Effect of Microwave Radiation on Uveal Melanoma Cells Excerpt from the Proceedings of the COMSOL Conference 2009 Boston An Efficient Finite Element Analysis on an RF Structure Used to Evaluate the Effect of Microwave Radiation on Uveal Melanoma Cells Andrei

More information

Selected Radio Frequency Exposure Limits

Selected Radio Frequency Exposure Limits ENVIRONMENT, SAFETY & HEALTH DIVISION Chapter 50: Non-ionizing Radiation Selected Radio Frequency Exposure Limits Product ID: 94 Revision ID: 1736 Date published: 30 June 2015 Date effective: 30 June 2015

More information

Official Journal of the European Communities. (Acts whose publication is not obligatory) COUNCIL

Official Journal of the European Communities. (Acts whose publication is not obligatory) COUNCIL 30. 7. 1999 EN Official Journal of the European Communities L 199/59 II (Acts whose publication is not obligatory) COUNCIL COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general

More information

RICHARD T ELL ASSOCIATES,INC.

RICHARD T ELL ASSOCIATES,INC. RICHARD T ELL ASSOCIATES,INC. An Evaluation of Test Measurement Data Obtained on the KW-Gard RF Protective Suit March 30, 1998 Prepared for Euclid Garment Manufacturing Company 333 Martinel Drive Kent,

More information

SAR Simulation in Human Head Exposed to RF Signals and Safety Precautions

SAR Simulation in Human Head Exposed to RF Signals and Safety Precautions Sahar Aqeel Abdulrazzaq et al IJCSET September 2013 Vol 3, Issue 9, 334-340 SAR Simulation in Human Head Exposed to RF Signals and Safety Precautions Sahar Aqeel Abdulrazzaq 1, Asst. Prof. Dr. Jabir S.

More information

Design of an U-slot Folded Shorted Patch Antenna for RF Energy Harvesting

Design of an U-slot Folded Shorted Patch Antenna for RF Energy Harvesting Design of an U-slot Folded Shorted Patch Antenna for RF Energy Harvesting Diponkar Kundu, Ahmed Wasif Reza, and Harikrishnan Ramiah Abstract Novel optimized U-slot Folded Shorted Patch Antenna (FSPA) is

More information

SAR TESTS ON MOBILE PHONES USED WITH AND WITHOUT PERSONAL HANDS-FREE KITS

SAR TESTS ON MOBILE PHONES USED WITH AND WITHOUT PERSONAL HANDS-FREE KITS SARTest Report 0083 July 2000 SAR TESTS ON MOBILE PHONES USED WITH AND WITHOUT PERSONAL HANDS-FREE KITS MI Manning and CHB Gabriel Report prepared for DTI. Page 1 of 17 Indemnity Sartest Limited makes

More information

Copyright 1996 IEEE. Reprinted from IEEE MTT-S International Microwave Symposium 1996

Copyright 1996 IEEE. Reprinted from IEEE MTT-S International Microwave Symposium 1996 Copyright 1996 IEEE Reprinted from IEEE MTT-S International Microwave Symposium 1996 This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE

More information

National Laboratory of Antennas and Microwave Technology Xidian University Xi an, Shaanxi 710071, China

National Laboratory of Antennas and Microwave Technology Xidian University Xi an, Shaanxi 710071, China Progress In Electromagnetics Research, PIER 76, 237 242, 2007 A BROADBAND CPW-FED T-SHAPE SLOT ANTENNA J.-J. Jiao, G. Zhao, F.-S. Zhang, H.-W. Yuan, and Y.-C. Jiao National Laboratory of Antennas and Microwave

More information

COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC)

COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC) COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC) THE COUNCIL OF THE EUROPEAN UNION, Having regard to

More information

How To Know If You Are Safe To Use An Antenna (Wired) Or Wireless (Wireless)

How To Know If You Are Safe To Use An Antenna (Wired) Or Wireless (Wireless) 1 2 The range of RF spans 3 KHz (3000 Hz) to 300 GHz (300 million Hz) Frequencies of RF devices range from the low frequency AM broadcasts (80 MHz) to higher frequency mobile phones (1900 MHz) smart meters

More information

Technical limits of Human Exposure to RF from Cellular Base Stations and Handsets

Technical limits of Human Exposure to RF from Cellular Base Stations and Handsets Ministry of Environmental Protection Ministry of Communications Technical limits of Human Exposure to RF from Cellular Base Stations and Handsets Based on author s PhD thesis/book- An analysis of regulatory

More information

Assessment of Human Exposure to Electromagnetic Radiation from Wireless Devices in Home and Office Environments

Assessment of Human Exposure to Electromagnetic Radiation from Wireless Devices in Home and Office Environments Assessment of Human Exposure to Electromagnetic Radiation from Wireless Devices in Home and Office Environments Sven Kühn, Urs Lott, Axel Kramer, Niels Kuster Foundation for Research on Information Technologies

More information

ANALYSIS AND VERIFICATION OF A PROPOSED ANTENNA DESIGN FOR AN IMPLANTABLE. RFID TAG AT 915 MHz RAHUL BAKORE

ANALYSIS AND VERIFICATION OF A PROPOSED ANTENNA DESIGN FOR AN IMPLANTABLE. RFID TAG AT 915 MHz RAHUL BAKORE ANALYSIS AND VERIFICATION OF A PROPOSED ANTENNA DESIGN FOR AN IMPLANTABLE RFID TAG AT 915 MHz By RAHUL BAKORE Bachelor of Engineering in Electronics and Communication University Of Rajasthan Jaipur, Rajasthan,

More information

Analysis of Immunity by RF Wireless Communication Signals

Analysis of Immunity by RF Wireless Communication Signals 64 PIERS Proceedings, Guangzhou, China, August 25 28, 2014 Analysis of Immunity by RF Wireless Communication Signals Hongsik Keum 1, Jungyu Yang 2, and Heung-Gyoon Ryu 3 1 EletroMagneticwave Technology

More information

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module Engineering Test Report No. 37802-02 Rev. A Measurement of RF Emissions from a Final Coat Electronics Corrosion Module For : Canadian Auto Preservation, Inc. 390 Bradwick Drive Concord, Ontario CANADA

More information

Attenuation Measurements of Materials Used in Construction of Buildings

Attenuation Measurements of Materials Used in Construction of Buildings Progress In Electromagnetics Research Symposium Proceedings, Guangzhou, China, Aug. 25 28, 2014 2671 Attenuation Measurements of Materials Used in Construction of Buildings Marek Bugaj Faculty of Electronics,

More information

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec This value-packed VuSpec CD-ROM represents the most complete resource available for professional engineers looking for

More information

Today s handsets have to meet tough ELECTROMAGNETIC SIMULATION OF MOBILE PHONE ANTENNA PERFORMANCE

Today s handsets have to meet tough ELECTROMAGNETIC SIMULATION OF MOBILE PHONE ANTENNA PERFORMANCE ELECTROMAGNETIC SIMULATION OF MOBILE PHONE ANTENNA PERFORMANCE The telecommunications sector is making great advances aimed at delivering an even stream of high-tech devices, covering the significant consumer

More information

Flexible PCB Antenna with Cable Integration Application Note Version 2

Flexible PCB Antenna with Cable Integration Application Note Version 2 Flexible PCB Antenna with Cable Integration Application Note Version 2 CONTENTS 1. BASICS 2. APPLICATIONS 3. SIZE 4. SHAPE 5. GROUND PLANE SIZE 6. IMPEDANCE 7. BANDWIDTH 8. VSWR 9. GAIN 10. EFFICIENCY

More information

GPR Polarization Simulation with 3D HO FDTD

GPR Polarization Simulation with 3D HO FDTD Progress In Electromagnetics Research Symposium Proceedings, Xi an, China, March 6, 00 999 GPR Polarization Simulation with 3D HO FDTD Jing Li, Zhao-Fa Zeng,, Ling Huang, and Fengshan Liu College of Geoexploration

More information

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02

More information

Design & Simulation of 8-Shape Slotted Microstrip Patch Antenna

Design & Simulation of 8-Shape Slotted Microstrip Patch Antenna World Applied Sciences Journal 31 (6): 1065-1071, 2014 ISSN 1818-4952 IDOSI Publications, 2014 DOI: 10.5829/idosi.wasj.2014.31.06.1462 Design & Simulation of 8-Shape Slotted Microstrip Patch Antenna Sohag

More information

INFLUENCE OF AVERAGING MASSES ON CORRELATION BETWEEN MASS-AVERAGED SAR AND TEMPERATURE RISE

INFLUENCE OF AVERAGING MASSES ON CORRELATION BETWEEN MASS-AVERAGED SAR AND TEMPERATURE RISE INFLUENCE OF AVERAGING MASSES ON CORRELATION BETWEEN MASS-AVERAGED SAR AND TEMPERATURE RISE A. Razmadze, L. Shoshiashvili, D. Kakulia, R. Zaridze Tbilisi State University, Tbilisi, 0128, Georgia, lae@laetsu.org

More information

Man-Faï Wong 1 and Joe Wiart 1

Man-Faï Wong 1 and Joe Wiart 1 ESAIM: PROCEEDINGS, October 2007, Vol. 22, 108-113 Gabriel Caloz & Monique Dauge, Editors ELECTROMAGNETIC MODELLING OF RADIOWAVES AND HUMAN BODIES INTERACTIONS Man-Faï Wong 1 and Joe Wiart 1 Abstract.

More information

RF Exposure Procedures TCB Workshop October 2012

RF Exposure Procedures TCB Workshop October 2012 RF Exposure Procedures TCB Workshop October 2012 Laboratory Division Office of Engineering and Technology Federal Communications Commission Overview Further updates on the RF exposure KDB drafts released

More information

Exposure Assessment of Smartphones and Tablets

Exposure Assessment of Smartphones and Tablets Exposure Assessment of Smartphones and Tablets Carla Oliveira, Michał Maćkowiak, Luis M. Correia Instituto Superior Técnico / INOV-INESC University of Lisbon, Portugal email: {carla.oliveira, luis.correia}@inov.pt

More information

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT 1. SCOPE This Common Regulatory Objective, CRO, is applicable to Wireless Local Area

More information

EM Noise Mitigation in Circuit Boards and Cavities

EM Noise Mitigation in Circuit Boards and Cavities EM Noise Mitigation in Circuit Boards and Cavities Faculty (UMD): Omar M. Ramahi, Neil Goldsman and John Rodgers Visiting Professors (Finland): Fad Seydou Graduate Students (UMD): Xin Wu, Lin Li, Baharak

More information

RF safety at base station sites

RF safety at base station sites RF safety at base station sites CONTENTS 1 Purpose and scope................................................. 2 2 Introduction........................................................ 2 3 Basic information...................................................

More information

for breast cancer detection

for breast cancer detection Microwave imaging for breast cancer detection Sara Salvador Summary Epidemiology of breast cancer The early diagnosis: State of the art Microwave imaging: The signal processing algorithm 2D/3D models and

More information

EFFECTS OF ELECTROMAGNETIC RADIATION FROM MOBILE PHONES AND CASE STUDIES OF COMPUTATIONAL MODELS FOR CALCULATING SAR DISTRIBUTION IN HUMAN BODY Settapong Malisuwan National Broadcasting and Telecommunications

More information

Electromagnetic Safety in Wireless Communications and Bio-Medical Technologies

Electromagnetic Safety in Wireless Communications and Bio-Medical Technologies A W H I T E P A P E R F R O M A N S Y S, I N C. Electromagnetic Safety in Wireless Communications and Bio-Medical Technologies Martin Vogel, ANSYS, Inc. I n t r o d u c t i o n In wireless-communication

More information

The waveguide adapter consists of a rectangular part smoothly transcending into an elliptical part as seen in Figure 1.

The waveguide adapter consists of a rectangular part smoothly transcending into an elliptical part as seen in Figure 1. Waveguide Adapter Introduction This is a model of an adapter for microwave propagation in the transition between a rectangular and an elliptical waveguide. Such waveguide adapters are designed to keep

More information

EN 50360:2001+A1:2012 SAR EVALUATION REPORT. Baoji Jiayuyutong electronic co.,ltd

EN 50360:2001+A1:2012 SAR EVALUATION REPORT. Baoji Jiayuyutong electronic co.,ltd EN 50360:2001+A1:2012 SAR EVALUATION REPORT For Baoji Jiayuyutong electronic co.,ltd Building A, 28# Longteng Street, Jianyi Village, Henggang Town, Longgang District, Shenzhen, P. R. China Model: JY-S3

More information

Measurement of Output Power Density from Mobile Phone as a Function of Input Sound Frequency

Measurement of Output Power Density from Mobile Phone as a Function of Input Sound Frequency , pp. 270-279. A Publication of the Measurement of Output Power Density from Mobile Phone as a Function of Input Sound Frequency Emanuele Calabrò and Salvatore Magazù Department of Physics, University

More information

FDTD Analysis of Site Free Space VSWR in Test Site Used for Disturbance Measurement above 1 GHz

FDTD Analysis of Site Free Space VSWR in Test Site Used for Disturbance Measurement above 1 GHz 九 州 工 業 大 学 学 術 機 関 リポジトリ Title FDTD analysis of site free space VS disturbance measurement above 1 GHz Author(s) Kuwabara N; Midori M; Kawabata M Issue Date 9-8 URL http://hdl.handle.net/8/368 9 IEEE.

More information

Insight on mobile phones and communication system:

Insight on mobile phones and communication system: Introduction: Rapid progresses are being made in wireless communications to make interactive voice, data and even video services available anytime and anyplace. Nowadays mobile phones are becoming ubiquitous.

More information

Design and Electromagnetic Modeling of E-Plane Sectoral Horn Antenna For Ultra Wide Band Applications On WR-137 & WR- 62 Waveguides

Design and Electromagnetic Modeling of E-Plane Sectoral Horn Antenna For Ultra Wide Band Applications On WR-137 & WR- 62 Waveguides International Journal of Engineering Science Invention ISSN (Online): 2319 6734, ISSN (Print): 2319 6726 Volume 3 Issue 7ǁ July 2014 ǁ PP.11-17 Design and Electromagnetic Modeling of E-Plane Sectoral Horn

More information

National Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields

National Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields November 2009 Contents 1 PRELIMINARY AND GENERAL... 5 1.1 CITATION... 5 1.2 ORIGIN AND STATUS OF THE NATIONAL GUIDELINES... 5 1.3 PURPOSE... 5 1.4 SCOPE AND APPLICATION... 6 1.5 TERMS AND DEFINITIONS...

More information

TWO-PORT ANTENNA WITH HIGH ISOLATION FOR DTV/GSM/UMTS INDOOR APPLICATIONS

TWO-PORT ANTENNA WITH HIGH ISOLATION FOR DTV/GSM/UMTS INDOOR APPLICATIONS Progress In Electromagnetics Research Letters, Vol. 10, 107 113, 2009 TWO-PORT ANTENNA WITH HIGH ISOLATION FOR DTV/GSM/UMTS INDOOR APPLICATIONS S.-G. Zhou, B.-H. Sun, Y.-F. Wei, and Q.-Z. Liu National

More information

A Novel Multi Frequency Rectangular Microstrip Antenna with Dual T Shaped Slots for UWB Applications

A Novel Multi Frequency Rectangular Microstrip Antenna with Dual T Shaped Slots for UWB Applications IOSR Journal of Electronics and Communication Engineering (IOSR-JECE) e-issn: 2278-2834,p- ISSN: 2278-8735.Volume 9, Issue 1, Ver. VI (Feb. 2014), PP 120-124 A Novel Multi Frequency Rectangular Microstrip

More information

WIRELESS MAGNETIC CONTACT

WIRELESS MAGNETIC CONTACT WIRELESS MAGNETIC CONTACT The magnetic contact wireless MAG HCS is a sensor able to detect opening or closing doors or windows and transmits via radio a alarm signal. It is composed of two distinct elements:

More information

MINIMUM USAGE OF FERRITE TILES IN ANECHOIC CHAMBERS

MINIMUM USAGE OF FERRITE TILES IN ANECHOIC CHAMBERS Progress In Electromagnetics Research B, Vol. 19, 367 383, 2010 MINIMUM USAGE OF FERRITE TILES IN ANECHOIC CHAMBERS S. M. J. Razavi, M. Khalaj-Amirhosseini, and A. Cheldavi College of Electrical Engineering

More information

Measurement of Output Radio Frequency Field Generated by Mobile Phones with Applied Sound in Different Strengths & Frequencies

Measurement of Output Radio Frequency Field Generated by Mobile Phones with Applied Sound in Different Strengths & Frequencies Gazi University Journal of Science GU J Sci 23(3):281-286 (21) www.gujs.org Measurement of Output Radio Frequency Field Generated by Mobile Phones with Applied Sound in Different Strengths & Frequencies

More information

RR649. Assessment uncertainties relating to electromagnetic fields (EMF) measurement and computation

RR649. Assessment uncertainties relating to electromagnetic fields (EMF) measurement and computation Health and Safety Executive Assessment uncertainties relating to electromagnetic fields (EMF) measurement and computation Prepared by EMFields Limited for the Health and Safety Executive 2008 RR649 Research

More information

Occupational Exposure Assessment on an FM Mast: Electric Field and SAR Values

Occupational Exposure Assessment on an FM Mast: Electric Field and SAR Values International Journal of Occupational Safety and Ergonomics (JOSE) 2012, Vol. 18, No. 2, 149 159 Occupational Exposure Assessment on an FM Mast: Electric Field and SAR Values Blaž Valič Institute of Non-Ionizing

More information

TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS

TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor Darul Ehsan, Malaysia Copyright of SKMM, 2007 FOREWORD

More information