D-Type Socket Assemblies

Size: px
Start display at page:

Download "D-Type Socket Assemblies"

Transcription

1 D-Type Socket Assemblies Socket Assembly Type No. For Side-on Types E0- E0- E- E- E-00 E-0 E- E-0 E- E-0 E- E- E- E- E- E- E-0 E-0 E- E- E E-00 E-0 E0-0 E0-0 E0-0 E E-0 Applicable MT Diameter mm (/") mm (-/") For Head-on Types mm (/") mm (/") mm (/") mm (") mm (-/") Anode Cathode / +- Outline and Diagram q w e r t y u @ rounded Electrode / Supply olarity Cathode /+ Maximum Ratings Insulation between Case and ins NOTE: AMeasured with the maximum supply voltage BMeasured with a supply voltage of 00 V except for E, E0 and E (00 V) CThe current at which the output linearity is kept within ± % (V) Supply (V) A Divider Current (ma) Leakage Current in Signal Max. (A) B Total Divider Resistance (MΩ) Maximum Linear Output in DC Mode (µa) (at 0 V) (at 0 V) (at 0 V) (at 0 V) (at 0 V) 0 (at 0 V) (at 0 V) (at 0 V) (at 0 V) (at 0 V) (at 0 V) (at 0 V) (at 00 V) (at 00 V) (at 00 V) (at 00 V) (at 0 V) 0 (at 00 V) (at 0 V) C Signal Output DC / ulse ulse DC / ulse (at 0 V) ulse DC / ulse (at 0 V) DC / ulse (at 00 V) ulse DC / ulse (at 00 V) E0-, DC / ulse DC / ulse DC / ulse in output DC / ulse E-, DC / ulse DC / ulse DC / ulse DC / ulse For, For E-, DC / ulse DC / ulse For For, DC / ulse DC / ulse ulse For Scintillation Counting E-, DC / ulse For 0, DC / ulse For, DC / ulse For, ulse for Scintillation Counting For, DC / ulse DC / ulse For DC / ulse DC / ulse Note E, For Scintillation Counting For Scintillation Counting E0-0, For, For, for Scintillation Counting E,

2 Socket Assembly Type No. E0-00 E0- E-00 E-0 E- E- E-0 E-0 E-0 E-00 E- E- E E-0 E-0 E- E E-0 E-0 E-0 Applicable MT Diameter For Head-on Types mm (-/") mm (-/") mm (") mm (") mm (") mm (") mm (") mm (") mm (") mm (") mm (") Outline and Diagram #0 # # # # # # # # # $0 $ $ $ $ $ $ $ $ $ rounded Electrode / Supply olarity Maximum Ratings Insulation between Case and ins (V) Supply (V) A Divider Current (at 0 V) (at 0 V) (at V) (at 0 V) ulse DC / ulse (at 0 V) ulse DC / ulse (at V) DC / ulse (at 000 V) ulse (at 000 V) (at 000 V) (at 0 V) (at 000 V) (at 00 V) (at 00 V) (at 0 V) (at 000 V) (at 0 V) (at 00 V) DC / ulse DC / ulse With connector For -0 DC / ulse With connector With connector, ulse for scintillation counting DC / ulse DC / ulse E E E mm (") Metal ackage MT 0U Series Metal ackage MT 00U Series %0 % % DC / ulse E0 E E E E Metal ackage MT D %. 00U-M Series (at 00 V) Metal ackage MT D %. 00U-L (at 00 V) Metal ackage MT %. 00U (at 00 V) Metal ackage MT D % M (at 00 V) Metal ackage MT D %. 00U- (at 00 V) DC / ulse DC / ulse DC / ulse DC / ulse DC / ulse E-0 For High Magnetic Environments mm (") % ulse NOTE: DCurrent of one anode CAUTION: Socket assemblies are not designed to operate in a vacuum. Temperature ranges of D-type socket assemblies are as follows (except for some products): Operating: 0 C to +0 C Storage: - C to +0 C Do not use the socket assemblies if condensation occurs, since a high voltage is output from the socket. Insert the photomultiplier tube all the way into the socket. Insert the photomultiplier tube straight into the socket, or pull the photomultiplier tube straight out of the socket when removing it. (ma) Leakage Current in Signal Max. (A) B Total Divider Resistance (MΩ) Maximum Linear Output in DC Mode (µa) C Signal Output Note For scintillation counting For scintillation counting For -0 For -0, with rear panel connector, with magnetic shield For scintillation counting E-, ulse with rear panel connector, for scintillation counting E-, DC / ulse with rear panel connector DC / ulse With rear panel connector For DC / ulse with rear panel connector DC / ulse With rear panel connector DC / ulse With rear panel connector With rear panel connector, ulse for scintillation counting DC / ulse For 0, for, DC / ulse with rear panel connector DC / ulse For R0,

3 D-Type Socket Assemblies Dimensional Outlines and Diagrams (Unit: mm) q E0- w E0-0. MAX..0 ± 0. 0 ±.0 ± 0.. ± 0.. ± 0. OTTIN COMOUND MT DY DY SOCET IN No. 0 R C C SINAL OUTUT R-/U (BLAC) OWER SULY ND AW (BLAC) to 0 : 0 kω to C : nf AW (VIOLET) 0. MAX..0 ± 0. 0 ±.0 ± 0.. ± 0.. ± 0. OTTIN COMOUND MT DY DY SOCET IN No. 0 R C C SINAL OUTUT R-/U (BLAC) to 0 : 0 kω to C : nf TACCA00EC TACCA00EB e E- r E-.0 ± ± 0..0 ± 0..0 ± 0..0 ± 0..0 ± 0. OTTIN COMOUND MT DY DY SOCET IN No. 0 R SINAL OUTUT R-/U(BLAC) OWER C SULY ND AW (BLAC) C to 0 : 0 kω to C : nf AW (VIOLET).0±0...0±0. A 0.0±0..0±0..±0..0± SOCET MT IN No. SINAL OUTUT (A) ND () 0 C C DY DY to 0 : 0 kω R to C : nf () * "Wiring diagram at above applies when is supplied." To supply,connect the pin "" to, and the pin "" to the ND. Refer to "(d) d-" on page for the connection method. TACCA000EH TACCA0EA t E-00 y E-0.0 ± ±.0 ± ± 0..0 ± 0..0 ± 0..0 ± 0. OTTIN COMOUND MT DY DY SOCET IN No. 0 R C C SINAL OUTUT R-/U (BLAC) R to 0: 0 kω to C: nf 0.0 ± 0. 0 ±. ± 0. OTTIN COMOUND MT DY DY SOCET IN No. 0 R C C SINAL OUTUT R-/U (BLAC) OWER SULY ND AW (BLAC) to : 0 kω to C: nf AW (VIOLET) TACCA0EC TACCA00ED

4 u E- i E ± 0. 0 ±. ± 0. OTTIN COMOUND SOCET MT IN No. 0 DY DY R C C SINAL OUTUT R-/U (BLAC) to : kω R to 0: 0 kω to C: nf 0.0 ± 0. 0 ±. ± 0. OTTIN COMOUND MT DY DY SOCET IN No. 0 R C C SINAL OUTUT R-/U (BLAC) OWER SULY ND AW (BLAC) to : kω R to 0 : 0 kω to C : nf AW (VIOLET) TACCA00EC TACCA00EB o E-!0 E-0 0 ±.0 ± 0. 0.MAX..0 ± 0.. ± 0.. ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. 0 to : 0 kω to C : nf R C C SINAL OUTUT R-/U (BLAC) OWER SULY ND AW (BLAC) AW (VIOLET) 0. MAX..0 ± 0. 0 ±.0 ± 0.. ± 0.. ± 0. OTTIN COMOUND MT SOCET IN No. C 0 0 C DY DY R SINAL OUTUT R-/U (BLAC) to : 0 kω to C: nf TACCA00EB TACCA00EC! E-! E- 0. MAX..0 ± 0. 0 ±.0 ± 0.. ± 0.. ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. 0 R C C SINAL OUTUT R-/U (BLAC) OWER SULY ND AW (BLAC) : MΩ : kω, to : 0 kω to C: nf AW (VIOLET) 0. MAX..0 ± 0. 0 ±.0 ± 0.. ± 0.. ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. 0 R C C SINAL OUTUT R-/U (BLAC) : 0 kω to : 0 kω to C: nf TACCA0EB TACCA00EB

5 D-Type Socket Assemblies Dimensional Outlines and Diagrams (Unit: mm)! E-! E-. ±.0 0 ±.0 ± 0..0 ± 0.. ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. 0 SINAL OUTUT R-/U (BLAC) OWER SULY ND AW (BLAC) : kω to : 0 kω to C : nf R C C AW (VIOLET). ±.0.0 ± 0. 0 ±.0 ± 0.. ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. C C 0 R C C SINAL OUTUT R-/U (BLAC) AW (RED) : kω to : 0 kω : 0 kω to C : nf C to C :. nf OWER SULY ND AW (BLAC) TACCA00EB TACCA00EB! E-! E-. ±.0.0 ± 0. 0 ±.0 ± 0.. ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. 0 R C C SINAL OUTUT R-/U (BLAC) : kω to : 0 kω to C : nf 0.0 ± 0. 0 ±.0 ± 0. OTTIN COMOUND MT SOCET IN No. 0 0 DY DY R C C SINAL OUTUT R-/U(BLAC) :0 kω : kω, to :0 kω to C: nf SHIELD CABLE(RED) TACCA0EB TACCA00EC! E-0! E-0.0 ± 0. 0 ±.. ± 0 0. OTTIN COMOUND MT SOCET IN No. C 0 C DY DY R SINAL OUTUT R-/U (BLAC) : MΩ :0 kω :0 kω, to :0 kω R: kω to C: nf.0 ± 0. 0 ±..0 ± 0 0. OTTIN COMOUND MT DY DY SOCET IN No. C SINAL OUTUT R-/U (BLAC) C AW (RED) C 0 C, : MΩ : 0 kω : 0 kω R: kω, to : 0 kω : kω R to C: nf C, C:. nf OWER SULY ND AW (BLAC) TACCA00EB TACCA0EB

6 ! E-. ±.0.0 ± 0. 0 ±.0 ± 0.. ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. 0 R C C SINAL OUTUT R-/U (BLAC) : 0 kω to : 0 kω to C: nf 0.0 ± ±.0 ± ± 0..0 ± 0..0 ± 0..0 ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. SINAL OUTUT R-/U (BLAC) OWER SULY ND 0 C C AW (BLAC) to, to : 0 kω R: kω to C: nf R AW (VIOLET) TACCA0EB E ± ±.0 ± ± 0..0 ± 0..0 ± 0..0 ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. 0 R C C SINAL OUTUT R-/U (BLAC) OWER SULY ND AW (BLAC) to : 0 kω to C: nf 0.0 ± ±.0 ± ± 0..0 ± 0..0 ± 0..0 ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. 0 R C C C SINAL OUTUT R-/U (BLAC) to : 0 kω to C: nf C:. nf AW (VIOLET) TACCA00EC E ± ±.0 ± ± 0..0 ± 0..0 ± 0..0 ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. C C 0 R C C SINAL OUTUT R-/U (BLAC) OWER SULY ND, : MΩ to : 0 kω to C : nf C, C :. nf * High voltage shielded cable can be connected to a connector for R-/U. 0.0 ± ±.0 ± ± 0..0 ± 0..0 ± 0..0 ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. 0 R C C SINAL OUTUT R-/U (BLAC) OWER SULY ND AW (BLAC) to : 0 kω to C : nf AW (VIOLET) TACCA0EA TACCA0EB

7 D-Type Socket Assemblies Dimensional Outlines and Diagrams (Unit: E ± ±.0 ± ± 0..0 ± 0..0 ± 0..0 ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. C C 0 R C C SINAL OUTUT R-/U (BLAC) AW (RED) to to C C, C : 0 kω : MΩ : nf :. nf OWER SULY ND AW (BLAC) 0.0 ± ±.0 ± ± 0..0 ± 0..0 ± 0..0 ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. 0 R C C SINAL OUTUT R-/U (BLAC) to : 0 kω to C: nf TACCA0EB E ± ±.0 ± ± 0..0 ± 0..0 ± 0..0 ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. 0 R C C C SINAL OUTUT R-/U (BLAC) OWER SULY ND AW (BLAC) to R, to : 0 kω : kω to : Ω to C : nf C :. nf 0.0 ± ±.0 ± ± 0..0 ± 0..0 ± 0..0 ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. C 0 R C C C SINAL OUTUT R-/U (BLAC) AW (RED) to R, to : 0 kω : kω to : Ω to C : nf C, C :. nf AW (VIOLET) TACCA0EB OWER SULY ND AW (BLAC) E- #0 E ± ±.0 ± ± 0..0 ± 0..0 ± 0..0 ± 0. OTTIN COMOUND MT SOCET IN No. 0 DY DY 0 R C C C SINAL OUTUT : R-/U (BLAC) : 0 kω : kω, to : 0 kω to : Ω to C: nf C:. nf 0.0 ± ±.0 ± ± 0..0 ± 0..0 ± 0..0 ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. 0 R C C C SINAL OUTUT R-/U (BLAC) to : 0 kω to C: nf C:. nf TACCA00EC TACCA0EA

8 # E0- # E ± ±.0 ± ± 0..0 ± 0..0 ± 0..0 ± 0. OTTIN COMOUND MT SOCET IN No. DY DY C 0 C R SINAL OUTUT R-/U (BLAC) OWER SULY ND AW (BLAC) : MΩ to, to : 0 kω : kω to C: nf AW (VIOLET) 0.0 ± 0. 0 ±..0 ± 0..0 ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. 0 R C C C SINAL OUTOUT R-/U (BLAC) : kω to : 0 kω to C : nf C :. nf TACCA0EB TACCA0EC # E-0 # E- 0.0 ± 0. 0 ±..0 ± 0..0 ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. C C C 0 R C C SINAL OUTUT R-/U (BLAC) to : 0 kω : MΩ, C, C:. nf C to C : nf.0 ± 0. 0 ±.0 ± 0..0 ± 0. DY DY MT SOCET IN No. 0 R C C C * The housing is internally connected to the ND. ** High voltage shielded cable can be connected to a connector for R-/U. SINAL OUTUT R-/U (BLAC) : kω, : 0 kω to : 0 kω to C: nf C:. nf OWER SULY ND TACCA0EB TACCA0EC # E- # E-0.0 ± 0. 0 ±.0 ± 0..0 ± 0. DY DY SOCET MT IN No. C 0 R C C C * The housing is internally connected to the ND. ** High voltage shielded cable can be connected to a connector for R-/U. SINAL OUTUT R-/U (BLAC) OWER SULY ND to : 0 kω to : 0 kω : kω : MΩ to C : nf C, C :. nf.0 ± 0. 0 ±.0 ± 0..0 ± 0. DY DY MT SOCET IN No. 0 R * The housing is internally connected to the ND. C C SINAL OUTUT R-/U (BLAC) OWER SULY ND AW (BLAC) to 0: 0 kω C to C: nf C:. nf AW (VIOLET) TACCA0EB TACCA0EB

9 D-Type Socket Assemblies Dimensional Outlines and Diagrams (Unit: mm) # E-0 # E-0.0 ± 0. 0 ±.0 ± 0..0 ± 0. SOCET MT IN No. C DY DY 0 R C C C * The housing is internally connected to the ND. ** High voltage shielded cable can be connected to a connector for R-/U. SINAL OUTUT R-/U (BLAC) OWER SULY ND to : 0 kω to C: nf C, C:. nf.0 ± 0. 0 ±.0 ± 0..0 ± 0. SOCET MT IN No. 0 DY DY 0 R * The housing is internally connected to the ND. C C C SINAL OUTUT R-/U (BLAC) OWER SULY ND AW (BLAC) : 0 kω to : 0 kω to C: nf C:. nf AW (VIOLET) TACCA0EB TACCA00EC # E-00 $0 E-.0 ± 0..0 ± 0. SINAL OUTUT : BNC-R.0 ± 0. SI MANETIC -M : SHV-R MT 0 DY DY ACC SOCET IN No. C C C C 0 C C C C C 0 R 0 * The housing is internally connected to the ND. SINAL OUTUT : kω, R: 0 kω, to, : 00 kω, : 0 kω to : 00 kω to : Ω : 0 pf C to C, : nf C: nf C: nf.0 ± 0. 0 ±.0 ± 0..0 ± 0. MT 0 DY DY SOCET IN No. C C C 0 R C C * The housing is internally connected to the ND. ** High voltage shielded cable can be connected to a connector for R-/U. SINAL OUTUT R-/U (BLAC) OWER SULY ND to : 0 kω : MΩ : kω to C : nf C, C :. nf TACCA00EB TACCA0EC $ E- $ E.0 ± 0. 0 ±.0 ± 0..0 ± 0. MT 0 DY DY SOCET IN No. 0 R C C C * The housing is internally connected to the ND. ** High voltage shielded cable can be connected to a connector for R-/U. SINAL OUTUT R-/U (BLAC) : kω to : 0 kω to C : nf C :. nf OWER SULY ND. ± 0. SINAL OUTUT : BNC-R.0 ± 0. SI +H.V -M OF MANETIC : SHV-R MT 0 DY DY SOCET IN No. C C C C 0 R C * The housing is internally connected to the ND. SINAL OUTUT to : 0 kω : MΩ : kω to C: nf C, C:. nf 0 TACCA0EB TACCA0EC

10 $ E-0 $ E-0. ± 0. SINAL OUTUT : BNC-R.0 ± 0. SI -M OF MANETIC : SHV-R MT SOCET IN No. SINAL OUTUT C 0 C 0 : kω DY to : 0 kω to C: nf C:. nf DY R C * The housing is internally connected to the ND. TACCA0EB.0 ± 0.. SINAL OUTUT :BNC-R.0 ± 0..0 ± ± 0. SI -M OF MANETIC :SHV-R MT 0 DY DY SOCET IN No. 0 0 R C C C SINAL OUTUT : kω to R, to : 0 kω : 0 kω, to,,: kω, to : 0 Ω : 0 pf C,C: nf C: nf * The housing is internally connected to the ND. TACCA0EC $ E- $ E.0 ± 0.. SINAL OUTUT :BNC-R.0 ± 0. ± ± 0. SI -M OF MANETIC :SHV-R 0 DY DY MT SOCET IN No. 0 0 R C C C SINAL OUTUT CASE ND : kω to, 0: 0 kω, : 0 Ω to, to : kω : Ω, : 0 Ω : 0. nf C, C: nf C: nf.0 ± 0.. SINAL OUTUT :BNC-R.0 ± 0..0 ± ± 0. SI -M OF MANETIC :SHV-R 0 DY DY SH MT SOCET IN No. 0 0 R C C C C C C SINAL OUTUT : kω,,, 0, : 0 kω,,, to : kω, R,, : kω, to : kω, : Ω, : 0 Ω : 0 pf C: nf C: nf C: 0. µf C to C: 0. µf * The housing is internally connected to the ND. TACCA00EA * The housing is internally connected to the ND. TACCA0ED $ E-0 $ E-0.0 ± 0.. SINAL OUTUT :BNC-R.0 ± 0..0 ± ± 0. SI -M OF MANETIC :SHV-R MT 0 DY DY SH SOCET IN No. 0 0 R C C C SINAL OUTUT : kω to, to : 0 kω,: kω to,,: kω : 0 Ω : Ω,: 0 Ω : 0 pf C,C: nf C: nf * The housing is internally connected to the ND..0 ± 0.. SINAL OUTUT :BNC-R.0 ± 0..0 ± ± 0. +H.V SI -M OF MANETIC :SHV-R MT 0 DY DY SH SOCET IN No. 0 C C 0 R C C C C C C SINAL OUTUT to R, to : 0 kω, : kω to 0,, : kω : 0 Ω : kω : Ω, : 0 Ω : 0 kω : MΩ, C : nf C : nf C, C :. nf C : 0 pf C to C :. nf TACCA0EC * The housing is internally connected to the ND. TACCA0EE

11 D-Type Socket Assemblies Dimensional Outlines and Diagrams (Unit: mm) $ E-0 %0 E.0 ± 0. 0 ±.0 ± ± 0. OTTIN COMOUND MT SOCET IN No. 0 DY DY C C 0 R C * The housing is internally connected to the ND. ** High voltage shielded cable can be connected to a connector for R-/U. SINAL OUTUT R-/U (BLAC) to : 0 kω to C: nf C:. nf OWER SULY ND TACCA0EB 0 ± 0. SINAL OUTUT (BNC-R).0 ± 0. SI : SHV-R 0 0 DY DY MT SOCET IN No. 0 C C C C 0 R * The housing is internally connected to the ND. C SINAL OUTUT : kω, : 0 kω : 0 kω : 0 kω R: 0 kω : 0 kω to : 0 kω, : kω : 00 kω : Ω 0, : 0 Ω : nf C: nf C: 0 nf C: 0 nf C: 0 nf C: 0 pf TACCA0EC % E % E MT SOCET IN No. UIDE MAR 0 0 DY DY R C C SINAL OUTUT R-/U (BLAC) OWER SULY ND AW (BLAC) to 0: 0 kω : kω to C: nf AW (VIOLET) TACCA0EB IN No. 0 ±.0 ± ± ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No R C C * High voltage shielded cable can be connected to a connector for R-/U. SINAL OUTUT R-/U (BLAC) to : 0 kω to : 0 kω to : Ω : MΩ to C : nf OWER SULY ND TACCA0EC % E0 % E IN No. 0.0 ± 0..0 ± 0. 0 ± OTTIN COMUND UIDE MAR 0.0 ± 0. SHIELD CABLE (RED) OTTIN COMOUND to : SINAL OUTUT COAXIAL CABLE (RAY) MT 0 DY DY SOCET IN No. 0 0 R C C * High voltage shielded cable can be connected to a connector for R-/U. SINAL OUTUT 0.D-QEV (RAY) to : 0 kω to : 0 kω to : Ω : MΩ to C : nf OWER SULY ND TACCA0ED in No. 0.0 ± 0. 0 ±.0 ± ± 0. UIDE MAR OTTIN COMOUND SHIELD CABLE (RED) to : SINAL OUTUT COAXIAL CABLE (RAY) MT 0 DY DY SOCET IN No. 0 0 R * High voltage shielded cable can be connected to a connector for R-/U. C C SINAL OUTUT 0.D-QEV (RAY) to : 0 kω to : Ω : MΩ to C: nf OWER SULY ND TACCA0ED

12 % E % E IN No. 0 ±.0 ± 0.. ± 0.. ± 0. OTTIN COMOUND MT 0 DY DY SOCET IN No. 0 0 R C C * High voltage shielded cable can be connected to a connector for R-/U. SINAL OUTUT R-/U (BLAC), : kω : 0 kω : 0 kω to : 0 kω to : Ω : MΩ to C: nf OWER SULY ND TACCA0EB IN No... ± 0..0 ± 0.. -M ND.0. ± ND DY OUT ND. =. ANODE OUTUT IN ( 0.) ND.. OUTUT ANODE OUTUT DY DY OUTUT 0 C 0 0 R ND ND C C, : kω, : 0 kω R to : 0 kω : MΩ to : Ω 0: kω to C: nf TACCA0EB % E % E-0 IN No.. ± 0..0 ± 0. 0 ± X X : SHIELD CABLE (RED) UIDE MAR. ± 0. Y X OTTIN COMOUND X X X Y Y Y Y Y X to X Y to Y: SINAL OUTUT COAXIAL CABLE (RAY) X Y X Y X Y X Y X Y X Y MT 0 DY DY SOCET IN No. 0 C C 0 0 R * High voltage shielded cable can be connected to a connector for R-/U. X Y X Y X Y X Y X Y X Y SINAL OUTUT : COAXIAL CABLE (RAY), : kω : 0 kω to : 0 kω : MΩ to : Ω to C: nf SHIELD CABLE (RED) OWER SULY ND.0 ± 0. 0 ±.0 ± 0..0 ± 0. OTTIN COMOUND MT SOCET 0 IN No. C 0 0 DY DY R C C C C C SINAL OUTUT R-/U (BLAC) : kω to : 0 MΩ : 0 kω 0, : MΩ to : Ω to C: nf C, C:. nf TACCA0EA TACCA0ED

Electro Optical Components, Inc. High Speed Current Amplifier

Electro Optical Components, Inc. High Speed Current Amplifier Electro Optical Components, Inc. 5460 Skylane Boulevard, Santa Rosa, CA 95403 Toll Free: 855-EOC-6300 www.eoc-inc.com info@eoc-inc.com Datasheet Features Bandwidth DC 400 MHz Rise / Fall Time 1 ns Optimized

More information

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011 Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.

More information

LSI/CSI LS7232ND TOUCH CONTROL LAMP DIMMER. LSI Computer Systems, Inc Walt Whitman Road, Melville, NY (631) FAX (631)

LSI/CSI LS7232ND TOUCH CONTROL LAMP DIMMER. LSI Computer Systems, Inc Walt Whitman Road, Melville, NY (631) FAX (631) LSI/CSI UL LSI Computer Systems, Inc. 35 Walt Whitman Road, Melville, NY 747 (63) 7-0400 FAX (63) 7-0405 A3800 TOUCH CONTROL LAM DIMMER January 003 FEATURES: hase-lock loop synchronization allows use in

More information

Cylinder Series PNC, to ISO 6431 and VDMA

Cylinder Series PNC, to ISO 6431 and VDMA Cylinder Series PNC, ISO 6431 and VDMA 24 562 Page 1 of11 Cylinder Series PNC, to ISO 6431 and VDMA 24 562 How to Order PNC ---------------- Ø ---------------------------- Stroke --------- S PNC: basic

More information

Variable Gain Low Noise Current Amplifier

Variable Gain Low Noise Current Amplifier Features Transimpedance (gain) switchable from 1 x 10 3 to 1 x 10 11 V/A Bandwidth DC/1 Hz... 500 khz Bandwidth switchable to DC... 10 Hz for low noise DC measurements Bandwidth independent of detector

More information

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)

More information

AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller

AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller 6 PIN INTERFACE CONNECTOR HEIGHT CONTROL KNOB CAP 04 CAPACITIVE HEIGHT CONTROLLER DOWN IN POSITION UP TOUCH CABLE FAULT AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines

More information

RX-AM4SF Receiver. Pin-out. Connections

RX-AM4SF Receiver. Pin-out. Connections RX-AM4SF Receiver The super-heterodyne receiver RX-AM4SF can provide a RSSI output indicating the amplitude of the received signal: this output can be used to create a field-strength meter capable to indicate

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

16/32A Charge plug SAE J1772. Charge connector 16/32A March 2010 - FCI COPYRIGHT

16/32A Charge plug SAE J1772. Charge connector 16/32A March 2010 - FCI COPYRIGHT 16/32A Charge plug SAE J1772 1 Charge plug applications SAE J1772 16/32A IEC 62196-2-2 16/32/63A Renault 2 SAE J1772 charge plug configurations Charging stations 16A and 32A : Domestic charging 16A : (mode

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

Automatic Antenna Switch for the AOR AR5000

Automatic Antenna Switch for the AOR AR5000 Langenbrettach, Jan. 5th 2012 Matthias Bopp Automatic Antenna Switch for the AOR AR5000 Rev. 1.0 Recently I was able to acquire second hand an AR5000 wideband receiver and wanted to extend the number of

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation.

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation. 14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0. Receiver AC-RX2/CS RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. Pin-out 38.1 3 Component Side 1 2 3 7 11 13 14 15

More information

D-Subminiature Series

D-Subminiature Series Rectangular Connectors Presentation Souriau D-Sub connectors are used for military/aerospace applications and in industrial field: information systems, communication systems, industrial electronic...

More information

Directory chapter 04

Directory chapter 04 M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................

More information

UTS discrete wire sealing

UTS discrete wire sealing Description Using proven grommet technology from SOURIAU s extensive knowledge of harsh environments, the UTS connector with grommet garanties a discrete wire sealing rated to IP67 (up to IP68 / IP69k

More information

PTU Series Ultrahigh-Purity Pressure Transducers

PTU Series Ultrahigh-Purity Pressure Transducers PTU Series UltrahighPurity Pressure Transducers User s Manual The Swagelok PTU series pressure transducer provides electronic monitoring of system pressure for ultrahighpurity applications. The PTU series

More information

HARTING econ 7000 Introduction and features

HARTING econ 7000 Introduction and features Introduction and features HARTING econ 7000 es, unmanaged, for use in harsh industrial environments General Description Features The es of the product family HARTING econ 7000 allow, according to type,

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

Installation Instructions. ThermoCall TC4. Entry/Advanced

Installation Instructions. ThermoCall TC4. Entry/Advanced Installation Instructions ThermoCall TC4 Entry/Advanced Thermo Call TC4 1 2 # 24990A 965 082 AMP 3 4 # 98393A # 67769A Thermo Call TC4 5 ThermoCall TC4 Entry 1 2 3 4 5 6 7 8 9 10 11 12 sw Please refer

More information

CIN::APSE MICROMINIATURE D-SUB

CIN::APSE MICROMINIATURE D-SUB INTRODUCTION CINCH has been producing filter connectors for years and has acquired an in depth knowledge of EMC protection. CINCH offers fast delivery on a wide range of standard filtered connectors and

More information

Automation Interface Requirements for J801 I/O Interface of a DPC III Welding System

Automation Interface Requirements for J801 I/O Interface of a DPC III Welding System - 1 - Automation Interface Requirements for J801 I/O Interface of a Welding System The welding system offers several features that are intended to communicate with automation. These features allow the

More information

UTS discrete wire sealing

UTS discrete wire sealing Technical characteristics Mechanical Durability: 250 matings & unmatings Vibration resistance: Sinusoidal vibrations per CEI 605-4 - from 10 to 2000 Hz Thermal shock: 5 cycles 30 min. from -40 C to 105

More information

Signal lamps. General information 3-2

Signal lamps. General information 3-2 Signal lamps Page General information - 2 Signal lamps with integrated LED - 5 Signal lamps with integrated LED, 5 mm - 6 Signal lamps with integrated LED, 7.0 mm - 12 Signal lamps with integrated LED,

More information

TX SAW MID 5V TRANSMITTER

TX SAW MID 5V TRANSMITTER TX SAW MID 5V TRANSMITTER SAW Transmitter module with external antenna, for utilisations with ON-OFF modulation of a RF carrier with digital data. Buffer stage for enhanced power and low harmonics on output

More information

Solid-State Timer H3G

Solid-State Timer H3G Solid-State Timer Low-Cost, Plug-In Timer with Large Switching Capacity Up to 7-amp switching capacity Choose SPDT or DPDT contact form 12 time ranges Fits standard 8-pin sockets Ideal replacement for

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

CHAPTER 5 HOW TO USE PHOTOMULTIPLIER TUBES AND PERIPHERAL CIRCUITS

CHAPTER 5 HOW TO USE PHOTOMULTIPLIER TUBES AND PERIPHERAL CIRCUITS CHAPTER 5 HOW TO USE PHOTOMULTIPLIER TUBES AND PERIPHERAL CIRCUITS This chapter explains how to use the basic circuits and accessories necessary to operate a photomultiplier tube properly. 1) 84 CHAPTER

More information

±15kV ESD-Protected, Quad, Low-Power RS-232 Line Receiver MAX1489E

±15kV ESD-Protected, Quad, Low-Power RS-232 Line Receiver MAX1489E 19-0426; Rev 0; 8/95 ±15k ES-rotected, Quad, General escription The 1489E quad, low-power line receiver is designed for EIA/TIA-232, EIA/TIA-562, and CCITT.28 communications in harsh environments. Each

More information

CAPACITIVE LEVEL METERS CLM 36

CAPACITIVE LEVEL METERS CLM 36 CAPACITIVE LEVEL METERS CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and quick connecting by

More information

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H, K-556H form A contact (normally open) for PCBs

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H, K-556H form A contact (normally open) for PCBs 50-5 Wrocław, ul. Krakowska 6, Poland tel. (+8) 7/-65-5, fax (+8) 7/-58-59 HV reed relays K-55H, K-55H K-55H, K-55H, K-555H, K-556H K-55H K-55H K-55H K-55H K-555H K-556H.CONTACT 0 Breakdown voltage min

More information

Product Information PI

Product Information PI Product Information PI "SD Series I.I." Toshiba X-ray Image Intensifier E5876SD-P2 Quadruple Input Field: 400/310/230/160mm (16 /12 /9 /6 ) Output Image Diameter: 35mm FEATURING: High Resolution High Conversion

More information

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current

More information

3x cinch/s-video socket Order no.: 33 1532 xx. USB/3.5 mm audio socket Order no.: 33 1539 xx. VGA socket Order no.: 33 1540 xx

3x cinch/s-video socket Order no.: 33 1532 xx. USB/3.5 mm audio socket Order no.: 33 1539 xx. VGA socket Order no.: 33 1540 xx 3x cinch/s-video socket Order no.: 33 1532 xx USB/3.5 mm audio socket Order no.: 33 1539 xx VGA socket Order no.: 33 1540 xx VGA socket with screw-in lift terminals Order no.: 33 1541 xx High definition

More information

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Industrial and transportation applications require robust connections with superior

More information

T M. IRDH275 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 08.

T M. IRDH275 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 08. T M 1 IRDH275 Series Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE1012021 / 08.2013 IRDH275 Series Digital ground fault monitor / ground

More information

LDG DTS-4/4R Desktop Coaxial Switch / Remote

LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com www.ldgelectronics.com

More information

Screw-in RTD temperature probe with plug connector according to DIN EN 175301

Screw-in RTD temperature probe with plug connector according to DIN EN 175301 ata sheet 902044 Page 1/8 Screw-in RT temperature probe with plug connector according to IN EN 175301 For temperatures between -50 and +260 C Vibration-resistant design Plug connector locked against contact,

More information

TX-SAW/433 s-z RFM Instruction Manual TX-SAW/433 s-z RFM Transmitter

TX-SAW/433 s-z RFM Instruction Manual TX-SAW/433 s-z RFM Transmitter TX-SAW/433 s-z RFM Transmitter SAW Transmitter module with external antenna, for utilisations with ON-OFF modulation of a RF carrier with digital data. Pin-out Lot (Week/Year) Code 15 1 Connections Pin

More information

SIRAX SI 815 Passive DC Signal Isolator

SIRAX SI 815 Passive DC Signal Isolator with power supply transfer and without separate power supply connection, versions available for FSK, Ex and non-ex versions 002 II () G Application The signal isolator SIRAX SI 85 (Fig. ) serves to electrically

More information

SOLENOID VALVES SERIES

SOLENOID VALVES SERIES CAD drawing data catalog is available. VALVES GENERAL CATALOG SOLENOID VALVES SERIES INDEX SOLENOID VALVES 010 SERIES Features 61 Basic Models and Configuration 62 Specifications 63 Solenoid Valve/Manifold

More information

ELECTRICAL CHARACTERISTICS OF TRANSMISSION LINES

ELECTRICAL CHARACTERISTICS OF TRANSMISSION LINES Page 1 of 6 ELECTRICAL CHARACTERISTICS OF TRANSMISSION LINES Transmission lines are generally characterized by the following properties: balance-to-ground characteristic impedance attenuation per unit

More information

USER MANUAL: JCI 178 Charge Measurement Unit

USER MANUAL: JCI 178 Charge Measurement Unit John Chubb Instrumentation Ltd Unit 30, Lansdown Industrial Estate, Gloucester Road, Cheltenham, GL51 8PL, UK. Tel: +44 (0)1242 573347 Fax: +44 (0)1242 251388 email: jchubb@jci.co.uk USER MANUAL: JCI 178

More information

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 1 - D.C. CIRCUITS

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 1 - D.C. CIRCUITS EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME - D.C. CIRCUITS Be able to use circuit theory to determine voltage, current and resistance in direct

More information

Switches and Indicators 17

Switches and Indicators 17 Switches and Indicators Switches and Indicators Index Series Description Page 197 Product Assembly Page 198 Product Range - pushbuttons for standard mounting - accessories / spare parts Technical Data

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

GV-VR605A DC Voltage Regulator

GV-VR605A DC Voltage Regulator Video 1 GV-VS04H www.geovision.com.tw Video 2 Video 3 Video 4 Audio 1 Speaker Out /Audio 2 Reset Ready Disk Full/ Audio 3 Load Fault Default /Audio 4 DC Voltage Regulator The is a voltage regulator designed

More information

Application Note 82 Using the Dallas Trickle Charge Timekeeper

Application Note 82 Using the Dallas Trickle Charge Timekeeper www.maxim-ic.com Application Note 82 Using the Dallas Trickle Charge Timekeeper DESCRIPTION The Dallas Semiconductor/Maxim real-time clock (RTC) family contains a number of parts within an integrated trickle-charging

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. Current Transducer CTSR series I PRN = 300, 600 ma Ref: CTSR 0.3-P, CTSR 0.6-P For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the

More information

DCS Input/Output Relay Card Series

DCS Input/Output Relay Card Series Input/Output Relay Card Series I/O RELAY CARD (with loopback test function) 8N The 8N series I/O Relay Cards easily and quickly standardize and facilitate installation of the relay board. Loopback test

More information

S101D01/S101D02 S201D01/S201D02

S101D01/S101D02 S201D01/S201D02 S1D1/S1D/S1D1/S1D S1D1/S1D S1D1/S1D 1-Pin DIP Type SSR for Low Power Control Features 1. Compact ( 1-pin dual-in-line package type). RMS ON-state current I T : 1.Arms 3. Built-in zero-cross (S1D, S1D ).

More information

Combi B Alarm box. Mounting instructions

Combi B Alarm box. Mounting instructions Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power

More information

08. SEK IDC CONNECTORS

08. SEK IDC CONNECTORS . IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these

More information

UT202A Operating Manual. Contents

UT202A Operating Manual. Contents Title Contents Page Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Functional Buttons and auto power off Display Symbols

More information

Wrist Strap Tester Operating Instructions

Wrist Strap Tester Operating Instructions 3 746 Wrist Strap Tester Operating Instructions 746 wrist strap tester 3 Listed Read and Understand all Safety Information Before Operating this Equipment. Safety Information Intended Use The 3M 746 Wrist

More information

SP724. TVS Diode Arrays

SP724. TVS Diode Arrays The is a quad array of transient voltage clamping circuits designed to suppress ESD and other transient over-voltage events. The is used to help protect sensitive digital or analog input circuits on data,

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

High Power Connectors for Power Supply and Power Circuits

High Power Connectors for Power Supply and Power Circuits Introduction Silver Plated Power Contacts with Contact Springs for Maximum Performance in Exposed Applications The demand for shortest possible periods of machine shut-downs and assembly times requires

More information

EMIT-3020L. Tel: 03-3980-2212. Analog Telephony / Modem Couplers DESCRIPTION. NOMENCLATURE (Fig. 1) MECHANICAL DIMENSIONS (Fig. 2)

EMIT-3020L. Tel: 03-3980-2212. Analog Telephony / Modem Couplers DESCRIPTION. NOMENCLATURE (Fig. 1) MECHANICAL DIMENSIONS (Fig. 2) EMIT-2L DESCRIPTION The REMtech Magnetics EMIT-2L is a Dry Encapsulated Modem Isolation Transformer suitable for up to V.9 (6 kbps) consumer and internet analog modem applications compliant with International

More information

6. Unsolder pin #4 and remove 3.9K (R211) and replace with 39K 2-Watt resistor.

6. Unsolder pin #4 and remove 3.9K (R211) and replace with 39K 2-Watt resistor. POWER MODIFICATION DAX X 1. Remove cabinet cover, bottom plate, and rear panel. 2. Remove 6DG6 tube and tube hold down clamp. 3. Remove 12BY7A tube and shield. 4. Unsolder pin 3 of octal socket R.F. power

More information

maxon sensor maxon sensor

maxon sensor maxon sensor Sensor Spindle drive Gearhead E Motor (BLD Motor) D Motor X Drives (configurable) Motor control obust encoders, D tachometers, and resolvers with high accuracy and high signal resolution. Due to resonance,

More information

Electro-Pneumatic Bus Door Control Mechanism

Electro-Pneumatic Bus Door Control Mechanism Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with

More information

Unipolar Stepper Motor Translators User Handbook

Unipolar Stepper Motor Translators User Handbook Mclennan Servo Supplies Ltd Unit 1, The Royston Centre Lynchford Road, Ash Vale GU12 5PQ Unipolar Stepper Motor Translators User Handbook Tel (44) 08707 700 700 Fax (44) 08707 700 699 Web www.mclennan.co.uk

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

RX-FM4SF 433,92 MHz User Manual. Connections

RX-FM4SF 433,92 MHz User Manual. Connections RX-FM4SF 433,92 MHz The super-heterodyne FM receiver RX-FM4SF with High sensitivity and selectivity. It is equipped by front-end SAW filter that allows an High noise immunity. Enable pin allows to reach

More information

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

FN2001-A1 Network module (SAFEDLINK) Mounting Installation FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without

More information

M-Bus Network Installation Notes

M-Bus Network Installation Notes M-Bus Network Installation Notes 1 M-Bus Network Installation Notes This manual explains how to calculate the maximum M-Bus cable length depends on technical parameters of used cable and number of M-Bus

More information

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater SALES SPECIFICATION SC7640 Auto/Manual High Resolution Sputter Coater Document Number SS-SC7640 Issue 1 (01/02) Disclaimer The components and packages described in this document are mutually compatible

More information

DVM810 DIGITAL MINI MULTIMETER DIGITALE MINI MULTIMETER MINI MULTIMETRE NUMERIQUE DIGITALES MINIMULTIMETER

DVM810 DIGITAL MINI MULTIMETER DIGITALE MINI MULTIMETER MINI MULTIMETRE NUMERIQUE DIGITALES MINIMULTIMETER DIGITAL MINI MULTIMETER DIGITALE MINI MULTIMETER MINI MULTIMETRE NUMERIQUE DIGITALES MINIMULTIMETER Instruction Manual Gebruikershandleiding Manuel d utilisation Gebrauchsanleitung 1. INTRODUCTION The

More information

3-Component Measuring System

3-Component Measuring System Force 3-omponent Measuring System for utting Force Measurement During Turning Modular system for measurement of cutting forces when turning outside and inside diameters on turret lathes. Machine adapters

More information

Subminiature Load Cell Model 8417

Subminiature Load Cell Model 8417 w Technical Product Information Subminiature Load Cell 1. Introduction... 2 2. Preparing for use... 2 2.1 Unpacking... 2 2.2 Using the instrument for the first time... 2 2.3 Grounding and potential connection...

More information

Brighter and Cooler. Apollo 600. Best Performance/Cost Ratio LED Flip Chip COB Module

Brighter and Cooler. Apollo 600. Best Performance/Cost Ratio LED Flip Chip COB Module Best Performance/Cost Ratio LED Flip Chip COB Module Brighter and Cooler Lower Thermal Resistance & Junction Temperature Apollo 600 Chip on Board is a high-performance LED module based on Flip Chip Opto

More information

LOW LOSS CABLE PAG. 1

LOW LOSS CABLE PAG. 1 LOW LOSS CABLE PAG. 1 INTRODUCTION Following many requests we received regarding the need for low-loss custom cable assemblies, we have set up a special production of high performance coaxial cable assemblies

More information

Type 940C, Polypropylene Capacitors, for Pulse, Snubber High dv/dt for Snubber Applications

Type 940C, Polypropylene Capacitors, for Pulse, Snubber High dv/dt for Snubber Applications Type 94C, Polypropylene Capacitors, for Pulse, Snubber Type 94 round, axial leaded film capacitors have polypropylene film and dual metallized electrodes for both self healing properties and high peak

More information

Trouble Case2 Suddenly, Feed Water Control?

Trouble Case2 Suddenly, Feed Water Control? Vol.5 Trouble Case2 Suddenly, Feed Water Control? Boiler Type : Steam Boiler Water is boiler s life. The parts which preside over the feed water control are very important. If the boiler is used under

More information

Installation Instructions. Thermo Call TC3

Installation Instructions. Thermo Call TC3 Installation Instructions Thermo Call TC3 1 2 # 24990A 965 082 AMP 3 4 # 98393A # 67769A sw Improper installation or repair of Webasto heating and cooling systems can cause fire or the leakage of deadly

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

74F174 Hex D-Type Flip-Flop with Master Reset

74F174 Hex D-Type Flip-Flop with Master Reset Hex D-Type Flip-Flop with Master Reset General Description The 74F174 is a high-speed hex D-type flip-flop. The device is used primarily as a 6-bit edge-triggered storage register. The information on the

More information

Supertex inc. HV264. Quad, High Voltage, Amplifier Array. Features. General Description. Applications. Block Diagram. Supertex inc.

Supertex inc. HV264. Quad, High Voltage, Amplifier Array. Features. General Description. Applications. Block Diagram. Supertex inc. Quad, High Voltage, Amplifier Array Features Four independent high voltage amplifiers 190V output swing 9.0V/µs typical output slew rate Fixed gain of 66.7V/V High value internal feedback resistors Very

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

MIDECO v.2 64-outputs MIDI note decoder

MIDECO v.2 64-outputs MIDI note decoder MIDECO v.2 64-outputs MIDI note decoder USER MANUAL Roman Sowa 2013 www.midi-hardware.com 1. Overview Thank you for choosing MIDECO as your new MIDI-to-digital converter. This short manual will guide you

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

COAX/SIGNAL HYBRID MICRO-D CONNECTORS

COAX/SIGNAL HYBRID MICRO-D CONNECTORS COAX/SIGNAL HYBRID MICRO-D CONNECTORS Omnetics high reliability Micro-D connectors are available with mixed coax/signal contact layouts. The number of coax and signal contacts may be specified to provide

More information

Analogue addressable devices

Analogue addressable devices Discovery Analogue addressable devices from Channel Safety Systems Discovery Analogue addressable devices Discovery is a range of high-specification, intelligent fire detectors that are developed to meet

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2 R Extended Range Inductive Prox Greater Sensing Distance Offers Greater Design Flexibility H Sensing distances approximately 1.5 to 2 times larger than that of any conventional Sensor H Reduces problems

More information

Electric lifting cylinder Compact Series

Electric lifting cylinder Compact Series Electric lifting cylinder Compact Series Table of Contents Glossary... 2 Compact serie SR 1... 4 Dimension SR 1... 5 Compact Serie SR 1SP... 6 Dimension SR 1SP... 7 Compact Serie SR 5... 8 Dimension SR

More information

SOURIAU s discrete wire sealing

SOURIAU s discrete wire sealing SOURIAU s discrete wire sealing Description Using proven grommet technology from SOURIAU s extensive knowledge of harsh environments, the UTO & UTS connectors with grommet garantie a discrete wire sealing

More information

LT-840 DMX512 Decoder Manual

LT-840 DMX512 Decoder Manual Manual Safety & Warnings Before you begin, read all warnings and installation instructions. This product is intended to be installed and serviced by a quali ed licensed electrician. Install in accordance

More information

Electro Optical Components, Inc. Variable Gain Low Noise Current Amplifier

Electro Optical Components, Inc. Variable Gain Low Noise Current Amplifier Electro Optical Components, Inc. 5460 Skylane Boulevard, Santa Rosa, CA 95403 Toll Free: 855-EOC-6300 www.eoc-inc.com info@eoc-inc.com Datasheet Features Transimpedance (Gain) Switchable from 1 x 10 3

More information

Application Note: XPort-AR Power over Ethernet

Application Note: XPort-AR Power over Ethernet Application Note: XPort-AR Power over Ethernet Lantronix, Inc. 15353 Barranca Parkway Irvine, CA 92618 Tel: +1 (949) 453-3990 Part Number 920-??? Revision A May 2005 Overview Power over Ethernet (PoE)

More information

1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels. Volkswagen; EuroVan, Passat

1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels. Volkswagen; EuroVan, Passat Article Text Saturday, March 18, 2000 10:33PM ARTICLE BEGINNING 1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels Volkswagen; EuroVan, Passat DESCRIPTION & OPERATION Instrument cluster for most

More information

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES FOR 50 OHM COAXIAL CONTACTS AND MODULES TABLE OF CONTENTS SECTION 1 RECEIVER CONTACT ASSEMBLY INSTRUCTIONS SECTION 2 ITA CONTACT ASSEMBLY INSTRUCTIONS

More information

Total solder points: 129 Difficulty level: beginner 1 2 3 4 5 advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL H2639IP-1

Total solder points: 129 Difficulty level: beginner 1 2 3 4 5 advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL H2639IP-1 Total solder points: 129 Difficulty level: beginner 1 2 3 4 5 advanced LIQUID LEVEL CONTROLLER K2639 Forgotten to turn off the tap, leaking washing machines,... Prevention is better than cure. So use this

More information

Pressure Sensors. for neutral and slightly aggressive liquids and gases

Pressure Sensors. for neutral and slightly aggressive liquids and gases 1909P01 Pressure Sensors for neutral and slightly aggressive liquids and gases QBE2003-P QBE2103-P High-precision measuring Measuring range 0 to 60 bar relative Supply voltage AC 24 V / DC 12...33 V or

More information

OLI. Oil level indicator

OLI. Oil level indicator OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap

More information