1 The advantages of raised access flooring 1 Note to the reader: The below is NOT a unique work or study, but rather an informative compilation of various studies done around the world to show the advantages of using a raised access floor from concetion phase right through to the recycling of the product after its lifespan as well as the duration in between. The advantages of raised access flooring The use of access floors in the workplace is rapidly gaining popularity since they present a solution that is specifically designed to support information-rich and highly computerised business environments. Owners and developers, along with building designers and facility managers, face the challenges of constantly changing space needs, technology-driven operations, high churn rates and the almost impossible task of maintaining flexibility while keeping life-cycle costs down. All of these challenges demand a new outlook on planning and constructing buildings and some insight into assuring that all building systems are integrated so they become mutually supporting. The costs of both change and maintenance are exceptionally high in traditionally planned buildings, and in many instances users defer needed changes at the cost of organisational comfort and efficiency. In fact, many traditionally designed facilities become obsolete due to wiring and wiring distribution problems created by organisational changes and advances in technology. If the building is planned correctly though, with enough thought and creativity, changes can become almost routine and technology can be easily integrated. A well-designed, intelligent building not only has the flexibility and the capacity to accommodate change, it actually promotes change. The concept behind access floors An access floor is a floor placed upon a floor, thus creating an accessible plenum for the distribution of building services such as power, voice and data and the distribution of heating and cooling services. The floor can be raised by as little at 65 mm to more than 1,8 metres. The system is modular with the ability to plug and unplug any of the electrical components in the entire system from the panel board to the receptacle. The finished floor surface can be carpet tile, vinyl tile, laminate, finished concrete or natural materials such as wood or cork. The underfloor HVAC system not only eliminates most of the ductwork and insulation requirements associated with the overhead systems, but also enhances mechanical system flexibility because the non-ducted diffusers can be easily removed and relocated. Floor-mounted diffusers or workstation-mounted solutions distribute conditioned air from the access floor directly to the occupant s level. From there the air gently mixes with the room air and rises to return grilles at ceiling level. The integrated access floor system also boosts the flexibility of telecommunications, data and electrical power delivery in the workstation. Simply by removing the access floor panels, building managers can now accommodate space and workstation changes as people relocate into, out of and around the office space. Benefits of access floors Integrated access floors for telecommunication, power and air distribution offer several economic and environmental benefits. Ease of reconfiguration, and easy access The integrated access floor system is engineered to permit fast, easy installation and quick wire and cable changes, enhancing the ability to reconfigure the offices without disrupting power, voice and data services, as well as the air distribution system.

2 The advantages of raised access flooring 2 Variable Air Volume (VAV) Terminals can be easily added, removed or rearranged to respond to changes in occupancy or heating and cooling loads. Even in workplaces with very low churn rates, constantly evolving technologies in the communications and networking sectors may demand occasional updating of the cabling and wiring systems. These updates are quite simple with access floors. Energy savings The use of an access floor plenum for conditional air distribution can significantly reduce energy use in many possible ways, such as a reduced fan power requirement. The underfloor supply plenum with the large cross-sectional flow areas can supply air with very low overall pressure drops. It also provides higher chiller efficiency. Underfloor systems can use warmer supply air, which permits a warmer cooling coil and warmer evaporator temperature in dry climates. In mild climates, the use of warmer supply air significantly expands the opportunity to use free cooling or the direct use of outside air, without operating a chiller. Also, since the airflow is from floor to ceiling, most of the heat generated from ceiling-mounted lights is removed before it can enter the occupied zone. The cooling load is therefore reduced, allowing warmer air to condition the space. In turn, the concrete slab becomes an active thermal mass, thus reducing temperature swings and peak cooling requirements, and permitting the realisation of benefits such as night precooling in underfloor air applications. Capital (First Cost) savings In new construction, the use of an access floor for service distribution can considerably reduce the overall building height, since floor plenums are usually shallower than ceiling plenums. Access floors can lower structural costs by allowing architects to reduce the floor-to-floor (slab-to-slab) height. In addition, the adjustable access floor pedestals accommodate imperfections in the floor slab, allowing the floor to be laser-levelled. The construction schedule can also be tightened by eliminating the need for slab screeding. Occupant health and comfort Reportedly, the most common complaints among employees are thermal discomfort and indoor air quality. With floormounted diffusers or workstation-mounted solutions such as task air modules or personal environment systems, the air is distributed directly to the workstation. The occupants have the ability to control both the volume and the direction of the incoming air, and the fan units can be turned off to accommodate reduced cooling requirements. As a result, personal comfort complaints are virtually eliminated. Case studies also show reduced absenteeism levels, since the system improves the indoor environmental conditions in other ways as well. These include air quality improvements due to better pollutant removal the upward flow of the supply air draws the pollutants upward rather than letting them swirl around with the room air. All these benefits could result, under certain conditions, in substantial overall cost savings. However, access floors are often eliminated from the building planning out of concern for higher first costs, but capital costs for the integrated system are comparable to traditional construction, while many other benefits detailed earlier result in significantly reduced life-cycle costs that are hard to overlook. Access floors are widely used throughout many countries and are a standard in Europe, UK, USA, Japan and the Middle East. For the majority of South African building professionals though, access floors still represent a relatively new and unfamiliar technology. The picture is now changing as we see growing acceptance of access floors by these building professionals. While access floors are most often used in new buildings, they have started to be utilised in renovation projects as well, with a greater role in structures being totally rehabilitated. In cases where the building interior is completely stripped, access floors become an excellent renovation tool, construction goes much faster, and pre-engineering work required to locate supply duct-work does not have to be performed. Developers have also begun to embrace the idea that the flexibility of integrated access floor systems, can and often do, cut move-in times and make generically designed office space suitable for a wide range of potential tenants.

3 The advantages of raised access flooring 3 Conclusions Pentafloor s range of access floors present a practical opportunity to economically accommodate the service distribution changes demanded by today s workplace. Use of access floors throughout an entire office building is the key not only to flexibility, but also to the ability to forestall building obsolescence. Pentafloor s range of access floors afford building owners and managers the capability to economically respond to tenant turnover, deliver superior flexibility and reduce labour, maintenance and energy costs while improving occupancy health, comfort and productivity. LEED : Credit Contribution Taking all the above into consideration, installing Pentafloor s range of access flooring can contribute towards achieving credits towards a LEED certification: Optimize energy performance Material re use Recycling of access flooring Re use of access flooring components Increases ventilation Thermal comfort Controllability of systems Reduced building height and construction materials Ease of reconfiguration, and easy access Installing an access floor system in your workplace allows for increased flexibility and brings with it a number of benefits. When you re able to house your power, data and telecommunications underneath your access floor, you will find that your workplace is much more flexible. You can create functional open plan areas with a flexible environment. All sorts of workplaces can benefit from installing an access floor, such as: Data centres and other computer rooms Office buildings Banks Schools and universities Call centres Television and film studios Museums Exhibition areas and showrooms

4 The advantages of raised access flooring 4 Energy savings In operation, an underfloor HVAC system operates at much lower pressure and warmer temperature than a traditional ducted overhead system, boosting indoor air quality, energy efficiency, and personal comfort control. These features help improve energy efficiency through the reduction of mechanical equipment and longer economizer hours. Reusing service supply materials such as wires, cables, outlets and diffusers during reconfiguration further improves the lifetime sustainability of any facility. See some examples showing how they're used in high performance buildings.

5 The advantages of raised access flooring 5 Keys to creating a more sustainable facility Deliver air from the floor at low pressure to utilize natural convection and maximize energy efficiency. Deliver air closer to the occupants so that warmer temperatures can be used expanding economizer opportunities. Power, voice, data, and heating and cooling services can all be reconfigured reusing the existing materials. Reduce construction materials thereby eliminating the harmful emissions required to produce and ship those materials. Include low VOC products made of recycled materials.

6 The advantages of raised access flooring 6 Capital (First Cost) savings In the construction phase, the Underfloor Service Distribution System allows a reduction in slab-to-slab height, decreasing construction materials required, eliminating ducts, wire and cable drop down lengths, and building shell materials.

7 The advantages of raised access flooring 7 Design phase guidelines and considerations Although the number of publications on underfloor technology has been on the increase in recent years, until recently there were no standardized design guidelines for use by the industry. Designers having experience with underfloor systems had largely developed guidelines and practices of their own. To address this situation, the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) initiated a research project to develop and publish a design guide on underfloor air distribution (UFAD) and task/ambient conditioning (TAC) systems. CBE completed this project in December of 2003, and the design guide is now available from ASHRAE. This section was developed before the completion of the Underfloor Air Distribution (UFAD) Design Guide published by ASHRAE. Please refer to the design guide for the most comprehensive and up-todate guidelines. UFAD vs. Conventional Overhead System Design UFAD systems are quite similar to conventional overhead systems in terms of the types of equipment used at the cooling and heating plants and primary air handling units (AHU). Key differences arise with UFAD systems in their use of an underfloor air supply plenum, localized air distribution (with or without individual control) and the resulting floor-toceiling air flow pattern, and the solutions used for perimeter systems. Although the methods used to calculate cooling and heating loads for a building with an UFAD system are similar to those used for conventional overhead systems, the calculation of design cooling air supply volumes requires different considerations. This is primarily due to the fact that overhead systems assume a single well-mixed temperature throughout the space (floor-to-ceiling), while UFAD systems assume that some amount of stratification occurs. The stratified floor-to-ceiling air flow pattern in UFAD systems allows most convective heat gains from sources outside the occupied zone (up to 1.8 m [6 ft]) to be exhausted directly at ceiling level, and therefore to not be included in the airside load (see further discussion below). In order to successfully employ an UFAD and raised access floor system, it is essential that the implications of these differences be considered, starting at an early stage in the design process.

8 The advantages of raised access flooring 8 The following is a step-by-step list of issues to be considered, and decisions to be made, during the design process. UFAD System Design Process: 1. Initial Building Design Considerations 1A. Building Section In new construction, underfloor air distribution can achieve a 5-10% reduction in floor-to-floor heights compared to projects with ceiling-based air distribution. This is accomplished by reducing the overall height of service plenums and/or by changing from standard steel beam construction to a concrete (flat slab) structural approach (see example table and figure below). A single large overhead plenum to accommodate large supply ducts can be replaced with a smaller ceiling plenum for air return combined with a lower height underfloor plenum for unducted air flow and other building services. Concrete flat slab construction is more expensive than steel beam construction, but is preferred for underfloor systems due to thermal storage benefits as well as significantly reduced vertical height requirements. In the example shown in the figure, the underfloor/concrete configuration allows 0.25 m (10 in.) to be saved in floor-to-floor height compared to overhead/steel beam system design. Even greater savings (up to 0.56 m [22 in.]) can be realized if the ceiling plenum is completely eliminated, exposing the concrete ceilings and providing an opportunity for greater architectural creativity. In this case, proper acoustic treatment must be incorporated into the new design. Underfloor plenums accommodating both cable/electrical distribution and an UFAD system are often deeper than those employed solely for cable management purposes. However, the additional height required for acceptable air flow performance is not large, based on recent CBE research results [6].

9 The advantages of raised access flooring 9 The following table presents a comparison of typical floor-to-floor dimensions for a midsize (5-10 stories), high-tech class A office building (assuming a 40-ft clear span between columns) [7]: Underfloor plenum heights are usually determined by: (i) (ii) largest HVAC components (e.g., fan coil units, terminal boxes, ducts, dampers) located under the floor; requirements for underfloor cabling; (iii) clear space for underfloor air flow (usually 76 mm (3 in.) minimum). 1B. Building Plan The modularity of all components of raised access floor systems can be an advantage in space planning, particularly over large open plan areas. Consider the compatibility of anticipated building plan geometries with the following typical system component dimensions. Raised access floor panel dimensions: 610 mm (24 in.) square Underfloor plenum pedestal spacing: as for floor panels, e.g. 610 mm (24 in.) Typical perimeter zone size (occupied area): 4 5 m (12 15 ft) deep, from the external wall. The largest dimension of system components (e.g., ducts) that can reasonably fit between underfloor pedestals is 560 mm (22 in.). Where structural members/ducts cross the pedestal grid, metal bridging can be installed, spanning from one panel to another in place of a pedestal. 2. Select System Configuration When configuring an UFAD system, there are three basic approaches: (1) pressurized plenum with a central air handler delivering air through the plenum and into the space through passive grills/diffusers; (2) zero-pressure plenum with air delivered into the conditioned space through local fan-powered (active) supply outlets in combination with the central air handler; and (3) in some cases, ducted air supply through the plenum to terminal devices and supply outlets. In the discussion below, we will focus on the two plenum supply configurations, as guidelines for fully ducted systems are well established.

10 The advantages of raised access flooring 10 2A. Pressurized Underfloor Plenum Supply air that has been filtered and conditioned to the required temperature and humidity, and includes at least the minimum required volume of outside air, is delivered by a conventional air handling unit through a minimum amount of ductwork to the underfloor plenum. The number of plenum inlet locations is a function of the size of control zones, access points available in the building, amount of distribution ductwork used under the floor, and other design issues. Within the underfloor plenum, it is always desirable to the extent possible to have the supply air flow freely to the supply outlets. Pressurized plenums are designed to deliver supply air at constant temperature and volume to all passive outlets of the same size and control setting within the conditioned space. Because the supply air in the underfloor plenum is in direct contact with the concrete structural slab, a number of energy- and cost-saving strategies are possible with UFAD systems. Such thermal storage strategies should be implemented with great care. See further discussion under section 12 - Develop a Control Strategy. The underfloor thermal mass also has the effect of providing a consistent cool air temperature reservoir (for cooling applications), making UFAD systems extremely stable in their operation. Almost all available floor diffusers allow some amount of individual control (usually volume and in some cases direction) by nearby occupants. There are several approaches to address zones with significantly different thermal loads: plenum partitioning with ducted VAV devices supplying air to each zone; plenum partitioning with fan-powered terminal devices supplying air to each zone; thermostatically controlled VAV diffusers may be used in both partitioned and open plenums; local fan-driven supply outlets may be used in both partitioned and open plenums; open plenums with mixing boxes and ducted outlets. Zoning and partitioning of the underfloor plenum should be kept to the minimum necessary to optimize UFAD performance and efficiency, as this helps to maintain the plenum for it's intended purpose: to serve as a highly flexible and accessible service plenum. There is some evidence from completed projects that uncontrolled air leakage from the pressurized plenum can impair system performance. It is important that proper attention be given to the sealing of junctions between plenum partitions, slab, access floor panels, and exterior or interior permanent walls during the construction phase of the project. Due to the relatively low pressure ( Pa [ in. H2O]) used in pressurized plenums, proponents of pressurized plenums claim that leakage into adjacent zones is minimal, and much of the leakage (between raised floor panels) will be into the same conditioned zone of the building [5]. This is a design issue that is still in need of further investigation. If access panels are removed for long periods of time, or the distance between primary air inlets and supply diffusers is too great, control of air flow will be diminished. Although not a requirement, some designers recommend limiting the size of underfloor zones (partitioned or otherwise) that are served by a single ducted primary air inlet, from the air handler (see below). This ensures the system's ability to avoid unacceptable variations in supply air temperature (due to heat gain from or loss to the concrete slab and raised floor structure) and quantity (due to pressure loss, obstructions, or friction) within the zone. In some system designs, using multiple medium or small-sized (floor-by-floor) AHU s can minimize or totally eliminate ductwork; and improve zone control when AHU capacities correspond to the specific requirements of each plenum zone. Some designs have resulted in higher pressures in the plenum on the order of 125 Pa (0.5 in. H2O); these have resulted in problems with over-conditioning, lifting of carpets, and problems with diffusers. Typical plenum pressure: Pa ( in. H2O) In some cases, maximum floor area served by each free-discharge supply air duct: 300 m2 (3,200 ft2)

11 The advantages of raised access flooring 11 2B. Zero-Pressure Underfloor Plenum Primary supply air from the central air handler is delivered to the underfloor plenum in much the same manner as with pressurized plenums. In this case, since the plenum is maintained at very nearly the same pressure as the conditioned space, local fan-powered supply outlets are required to supply the air into the occupied zone of the space. Zeropressure plenums pose no risk of uncontrolled air leakage to the conditioned space/adjacent zones. The removal of floor panels does not disrupt overall supply-air flow. Local fan-powered outlets under thermostatic or individual control allow supply air conditions to be controlled over a wide range as necessary. This controllability can be used to handle zones with significantly different thermal loads without underfloor partitioning. The use of partitioning for zone control can also be applied in a similar way as for pressurized plenums. Zoning and partitioning of the underfloor plenum should be kept to the minimum necessary to optimize UFAD performance and efficiency, as this helps to maintain the plenum for it's intended purpose: to serve as a highly flexible and accessible service plenum. Since the supply air in the underfloor plenum is in direct contact with the concrete structural slab, the same thermal storage strategies as with pressurized systems can be used (see section 12 - Develop a Control Strategy). Similarly, the frequency of ducted primary air inlets to the plenum must take into consideration the heat exchange between the supply air and the underfloor plenum structural mass. By relying on both a primary air handler and local fan-powered outlets to draw air from the plenum into the space, zeropressure configurations can more reliably maintain some amount of cooling effect if the chillers are off due to the thermal inertia of the concrete slab. The greater ability of zero-pressure systems to provide localized cooling suggests their suitability in projects involving high and diversified heat loads. In some system designs, using multiple medium or small-sized (floor-by-floor) AHU s can minimize or totally eliminate ductwork; and improve zone control when AHU capacities correspond to the specific requirements of each plenum zone. Compliance with local Fire Codes may require sprinklers and partitioning to be installed in all plenum configurations. 3. Determine space cooling and heating loads Cooling and heating loads for a building with an UFAD system are calculated in much the same manner as for a conventional overhead system. However, the determination of design cooling air quantities must take into account key differences between these systems. 3A. Cooling The stratified floor-to-ceiling air flow pattern in UFAD systems allows most convective heat gains from sources outside the occupied zone (up to 1.8 m [6 ft]) to be exhausted directly at ceiling level, and therefore to not be included in the air-side load. Air supply volumes therefore only consider heat sources that enter and mix with air in the occupied zone. Heat sources must be analyzed based on their convective and radiative components, a subject addressed by [8]. Depending on the location of the heat source in the space, some amount of the convective portion can be neglected in this calculation. An overview of this design approach is described in [9]. Other issues that can affect load calculations include the heat exchange between the concrete slab and the supply air as it flows through the underfloor plenum. If the slab has absorbed heat, particularly from warm return air from the next floor down flowing along the underside of the slab, then supply temperature will increase with distance from the primary air inlet to the plenum. Supply air in the plenum will also be warmed by heat transfer from the room through the raised floor panels. Estimates of supply air temperature rise as a function of air travel distance in an underfloor plenum are given in [10]. This is also the subject of ongoing CBE research. Another difference between UFAD design and overhead systems is consideration of heat loss through the access floor. This adds another component to the space cooling load calculation - estimated to be as high as 0.1 W/m2 (1 W/ft2). Most of this heat transferred through the floor into the supply air stream will reenter the conditioned space, although not instantaneously due to the mass of the floor panels. Research indicates that stratification for UFAD systems can result in overall delta T's (return-supply temperature difference) in the range of 8-11 C (15-20 F), for properly designed systems. However, these values are not what determine the air flow requirement. The heat gain to the occupied zone and the air flow required to maintain a given comfort condition in that zone is what determines the actual air flow requirements, and consequently the overall delta T that will be developed. Typically this results in air flow rates that can be equal to or less than that for overhead systems, even for higher supply air temperatures.

12 The advantages of raised access flooring 12 3B. Heating In most applications, heating is primarily needed only near the building envelope where cold downdrafts from perimeter glass may cause discomfort. Heating may also be needed in some top floor interior zones and during periods of low occupancy (e.g., nights and weekends). Effective heating systems isolate the source of warm air from the thermal lag effect of the concrete slab (which is usually slightly cooler than room temperature). This can be done, for example, by ducting from an underfloor fan coil unit, or by using baseboard radiation or convection units. Quick response on heating can be very important during morning startup. 4. Zoning 4A. Perimeter Zones The largest loads typically occur near the skin of the building. Since these areas are influenced by climatic variations, rapid fluctuations in heating and cooling demands can happen, with peak loads often occurring only for several hours per day and relatively few days of the year. Energy-efficient envelope design is always the first stage of defense against excessive perimeter loads. Under cooling conditions, the warm interior surface temperatures at the perimeter (due to either highly absorptive glazing or intercepted solar radiation if blinds are present) will form a strong vertical plume that can be removed with only part of the load contributing to the air-side load. Perimeter zone considerations often lead to hybrid system designs in which active, fan-powered supply units are used to increase the rate at which the system can respond to changes in load. Many perimeter zone solutions have been successfully applied in practice (see Plan Views for a few examples). Some manufacturers offer equipment and recommended configurations for perimeter systems [10, 11]. 4B. Interior Zones Interior zones (defined as areas located further than 5 m (15 ft) from exterior walls) are usually exposed to relatively constant and lower (compared to perimeter zones) thermal loads (almost always cooling in typical office buildings). However, with modern energy efficient office equipment and high diversity rates of personnel, these loads can fluctuate significantly; control strategies and system design need to be well thought out to accommodate these conditions. These zones can often be well served by a constant volume, or constant pressure in a pressurized system, control strategy. The need for dynamic control of these (typically) large zones is minimized due to the ability of occupants to make small local adjustments to individual diffusers. This configuration with a minimum amount of underfloor partitioning helps to maintain flexibility in the relocation of other services (e.g., cabling). The interaction between interior and perimeter systems needs careful consideration. For example, if plenum air is used to supply cooling for perimeter zones, reset of SAT for the core zones may militate against being able to satisfy perimeter load conditions. 4C. Other Special Zones Other special zones having large and rapid changes in cooling load requirements, such as conference rooms or lecture halls, should incorporate fan-powered or VAV air supply solutions. This can require underfloor partitioning for these areas. Automatic controls to these zones should be capable of meeting both peak demand and significant turndown during periods of little or no occupancy. Manual control of these zones has also been used in some installations. Partition construction: Vertical sheet metal dividers Perimeter zone dimensions: Typically extending 4 5 m (12 15 ft) from external wall.

13 The advantages of raised access flooring Determine ventilation air requirements Minimum outside air requirements should be determined according to applicable codes (e.g., ASHRAE Standard ). Some improvement in ventilation effectiveness is expected by delivering the fresh supply air near the occupant at floor or desktop level, allowing an overall floor-to-ceiling air flow pattern to more efficiently remove contaminants from the occupied zone of the space. An optimized strategy is to control supply outlets to allow mixing of supply air with room air up to a height no higher than head level (6 ft [1.8 m]). Above this height, stratified and more polluted air is allowed to occur. The air that the occupant breathes will have a lower percentage of pollutants compared to conventional uniformly mixed systems. If an enhanced air change effectiveness can be shown to exist in comparison to well-mixed overhead systems (see ASHRAE Standard ) future versions of ASHRAE Standard 62 may allow some credit to be taken, thereby allowing reduced ventilation air quantities. The magnitude of this improved air change effectiveness will be largest during times of outside-air economizer use. The fact that the number of hours of economizer operation is typically greater for UFAD systems also contributes to overall increased ventilation effectiveness. 6. Determine zone supply air temperature and flow rate Because the air is supplied directly into the occupied zone, supply air temperatures must be warmer than that used for conventional overhead system design. For cooling applications, supply air temperatures at the diffusers should be maintained no lower than in the range of C (63 68 F) to avoid overcooling nearby occupants. This supply temperature can be reset even higher under partial load conditions. Mixed air temperature after the cooling coil, or plenum inlet temperature, must be determined by taking into account temperature increase (or decrease, depending on the slab temperature) as the air flows through the underfloor plenum. Current estimates for typical air flow rates in an underfloor plenum with a slab that is 3 C (5 F) warmer than the plenum inlet air temperature call for a 1 C (2 F) increase for every 10 m (33 ft) of distance traveled through the plenum. In temperate climates, where high humidity is not a problem, these warmer supply air temperatures increase the potential for economizer use, and allow higher cooling coil temperatures to be set, if desired. Cooling air quantities for UFAD systems should be carefully determined. Higher supply air temperatures would suggest that higher supply air volumes are required, but the higher return temperatures created by stratification reduce the required increase in volume. Finally, as previously described, a calculation of the portion of heat sources that bypass the occupied zone in the space allows cooling air quantities to be further reduced. The net effect is that for most designs, controlled stratification in the space allows cooling air quantities for UFAD systems to be equal to or less than those required under the same conditions using overhead air distribution. As discussed further below under controls, control strategies for temperature and flow rate will vary depending on the magnitude and variability of loads in each control zone, as well as other system design issues. Supply air temperature - Return air temperature UFAD C (63-68 F) C (77-86 F) Systems Overhead 13 C (55 F) - 24 C (75 F) Systems 7. Determine return air configuration For optimal cooling operation of a UFAD system, it is important to locate return grills at ceiling level, or at a minimum, above the occupied zone (1.8 m [6 ft]). Air is typically returned through grilles located in a suspended ceiling or through high side-wall grilles if no ceiling plenum is present. This supports an overall floor-to-ceiling air flow pattern that takes advantage of the natural buoyancy produced by heat sources in the office and more efficiently removes heat loads and contaminants from the space. A certain portion of return air is mixed with primary air from the AHU to achieve desired air temperatures and humidity, and enable reduced energy costs. In many climates to achieve proper humidity control, conventional cooling coil temperatures must be used (producing a coil leaving temperature of 12.8 C (55 F)). In this situation, a return air bypass control strategy can be employed in which a portion of the return air is bypassed around the cooling coil and then mixed with the air leaving the coil to produce the desired warmer supply air temperature (17-20 C [63-68 F]). In some cases, a percentage of return air can be re-circulated directly back into the underfloor plenum via return shafts near the ceiling or from the ceiling plenum. Room air flowing back into the plenum through open floor grills can also serve as make-up air for zero pressure plenum designs when local fan-powered outlets require more air than that being supplied from the central AHU. If re-circulation takes place directly in the underfloor plenum, the supply and return air streams must be well mixed within the underfloor plenum before delivery to the conditioned space. This can usually be achieved by distributing the primary air at regularly spaced intervals throughout the plenum, and/or employing fan-powered local supply units to aid mixing of primary supply air with the return air.

14 The advantages of raised access flooring Calculate cooling coil load The calculation of cooling coil load is done in much the same manner as for a conventional mixing-type air distribution system. All of the loads in the space (some of which have bypassed the occupied zone, allowing a reduction in cooling air-side loads) must be handled at the coil. Humidity control considerations require that, in more humid climates the cooling coil be operated to produce the necessary dehumidification of outside air resulting in a coil leaving air temperature of 12.8 C (55 F). This air is then mixed with warmer bypassed return air to produce the desired plenum inlet air temperature. It is important that these systems use enthalpy based economizer control to ensure proper supply air humidity control. In temperate climates, the warmer supply air temperatures of UFAD systems increase the potential for economizer use and may also allow higher cooling coil temperatures than for conventional overhead systems, thereby increasing chiller efficiencies. 9. Layout ducts and plenum configuration Underfloor ducts serving specific zones should be sized to accommodate peak cooling loads. The capacity of the central chiller plant, air handlers and main duct risers can generally be reduced by accounting for time variations and load diversity (up to 50%). The design and layout of main ducts from the central plant to plenum inlet locations is similar to that of conventional overhead systems except that access must be provided for the ducts to reach the underfloor plenum. The amount of main ductwork can be reduced in designs using medium to small-sized air handlers (floor-by-floor units) that are located closer to the point of use. However, ductwork for ventilation air is still required and must be sized accordingly if the use of an outside-air economizer will be an important operating strategy. The amount of re-circulation ductwork can be reduced by taking some of the return air at ceiling level directly back into the underfloor plenum without returning to the air handler. For example, return air can be brought down induction shafts formed with furring spaces along structural columns. This alternative configuration of bypass control can be used as long as proper dehumidification is maintained back at the air handler and complete blending of return and supply air is achieved within the underfloor plenum. The height of underfloor plenums is generally determined by the largest HVAC components located under the floor. These components can typically be distribution ductwork, fire dampers at plenum inlets, fan coil units, and terminal boxes. Commercially available HVAC products allow plenum configurations as low as 0.2 m (8 in.), although heights in the range of m (12-18 in.) are more common. In pressurized plenums as low as 0.2 m (8 in.), full-scale experiments have demonstrated that static pressure remains very uniform across the entire plenum, making balancing of individual diffusers unnecessary [6]. These same experiments also showed that solid obstructions, even with only 38 mm (1.5 in.) of clear space above them, may be located in a 0.2-m (8-in.) or higher plenum and have very little impact on the uniformity of the overall pressure and air flow distribution. In both zero-pressure and pressurized plenums, the delivery of air through fan-powered outlets is even more reliable than that through passive diffusers in pressurized plenums. Active diffusers are less susceptible to pressure variations (such as when access floor panels are removed) and other flow restrictions. 10. Select primary HVAC equipment Due to the low operational static pressures in underfloor air supply plenums (typical pressures are around 25 Pa (0.1 in. H2O)), central fan energy use and sizing can potentially be reduced relative to traditional ducted overhead air distribution systems depending on the design strategy adopted (see [12] for a more complete discussion of this issue). As discussed earlier, cooling air quantities, and therefore air handler capacities, for UFAD systems should be carefully determined and may be equal to or less than those required under the same conditions using overhead systems. Although the total space cooling load is similar for both UFAD and conventional overhead systems, higher supply and return air temperatures in UFAD systems allow higher efficiency chillers to be used, when suitable weather conditions, and in particular humidity conditions, prevail. Thermal storage strategies using nighttime precooling of the concrete slab in the plenum can reduce peak demand for mechanical cooling during the following day, thereby allowing refrigeration equipment to be downsized. 11. Select and locate diffusers The flexibility of mounting supply diffusers in movable raised access floor panels is a major advantage for UFAD systems. The inherent ability to easily move diffusers to more closely match the distribution of loads in the space makes the placement of diffusers a much easier task. In fact, initial layout can be done quite crudely. Final placement can take place after the location of furniture and loads, as well as the preferences of individual occupants, are more accurately determined.

15 The advantages of raised access flooring 15 11A. Passive Diffusers Passive diffusers are defined as air supply outlets that rely on a pressurized underfloor plenum to deliver air from the plenum through the diffuser into the conditioned space of the building. Swirl floor diffusers, constant velocity floor diffusers, and linear floor grills are the primary types of floor diffusers (see below). Diffuser Types: Swirl Airflow pattern - Swirling upwards, rapid mixing. Adjustability - Rotate grill or bucket to adjust air flow volume. Ideal Location - Interior and perimeter zones. Constant Velocity Airflow pattern - Multi directional, air jet. Adjustability - Adjust grill for changes to air flow direction, thermostat for air flow volume. Ideal Location - Interior and perimeter zones. Linear Airflow pattern - Planar sheet, air jet. Adjustability - Multi-blade damper is used to adjust air flow volume. Ideal Location Perimeter zones Swirl floor diffuser Constant velocity floor Linear floor grill diffuser Swirl Floor Diffusers. This is the most commonly installed type of diffuser in UFAD systems; more models are commercially available than any other design. The swirling air flow pattern of air discharged from this round floor diffuser provides rapid mixing of supply air with the room air in the occupied zone. Swirl diffusers are generally installed as passive diffusers, requiring a pressurized underfloor plenum, although fan-driven models are available. Occupants have limited control of the amount of air being delivered by rotating the face of the diffuser, or by opening the diffuser and adjusting a volume control damper. Constant Velocity Floor Diffusers. This recently introduced diffuser is designed for variable-air-volume operation. It uses an automatic internal damper to maintain a constant discharge velocity, even at reduced supply air volumes. This is a passive diffuser (power is needed for the damper motor only), requiring a pressurized plenum, but fan-driven configurations are also available. Air is supplied through a slotted square floor grill in a jet-type air flow pattern. Occupants can adjust the direction of the supply jets by changing the orientation of the grill. Supply volume is controlled by a thermostat on a zone basis, or if available, as adjusted by an individual user. Linear Floor Grills. Linear grills have been used for many years, particularly in computer room applications. Air is supplied in a jet-type planar sheet making them well matched for placement in perimeter zones adjacent to exterior windows. Although linear grills often have multi-blade dampers, they are not designed for frequent adjustment by individuals, and are therefore not typically used in densely occupied office space. It is recommended that you contact the diffuser manufacturers directly to obtain the most up-to-date product information on passive diffusers.

16 The advantages of raised access flooring 16 11B. Active Diffusers Active diffusers are defined as air supply outlets that rely on a local fan to deliver air from the plenum through the diffuser into the conditioned space of the building. Passive diffusers can generally be converted to an active diffuser by simply attaching a fan-powered outlet box to the underside of the diffuser or grill. Most manufacturers provide both passive and active diffusers. In addition to the three types of diffusers described above for passive diffusers, several different designs for active diffusers are available. Fan-powered diffusers include: Floor supply module, consisting of four round discharge grills (jet-type) mounted in a single raised floor panel. Fixed vanes in the grills are inclined at 40, so that air flow direction can be adjusted by rotating the grills. A rotary speed control knob recessed into one grill allows air supply volume (fan speed) to be controlled [13-19]. Please check on the availability of this unit with the manufacturer. Desktop air supply pedestals (typically two), which are fully adjustable for air flow direction, as well as air supply volume by adjusting a control panel on the desk. Air is supplied from a mixing box that is typically hung in the back or corner of the knee space of the desk and connected by flexible duct to the two desktop supply nozzles. The mixing box uses a small variable-speed fan to pull air from the underfloor plenum and deliver a free-jet-type air flow from the nozzles [15, 18-22]. Under-desk diffusers, which consist of one or more fully adjustable (for air flow direction) grills, similar to a car's dashboard. A fan unit located either adjacent to the desk or in the underfloor plenum delivers air through flexible duct to the grills (jet-type) mounted just below and even with the front edge of the desk surface (other positions are possible). Two primary models are available. One allows adjustment of the fan speed to change air supply volume [18, 19], and the other uses a damper to adjust air supply volume towards the occupant while maintaining a thermostatically controlled total volume (through other supply outlets) into the space [23]. Partitionbased diffusers, mounted in the partitions immediately adjacent to the desk. Air is delivered through passageways that are integrated into the partition design to controllable supply grills (jet-type) that may be located just above desk level or just below the top of the panel. Although uncommon in the U.S., some of these systems have been installed in Japan [24]. It is recommended that you contact the diffuser manufacturers directly to obtain the most up-to-date product information on active diffusers.

17 The advantages of raised access flooring Develop control strategy 12a Temperature, humidity, and volume control As described earlier, since air is supplied directly into the occupied zone near floor level, supply outlet temperatures should be maintained no cooler than in the range of C (63-68 F) to avoid overcooling nearby occupants. To achieve the required higher supply air temperatures while still maintaining humidity control the following approach, called side-stream bypass, is often used. Cooling coil temperatures are typically in the range of C (50-55 F) for dehumidification purposes. Only the incoming outside air and a portion of the return air is dehumidified (minimum amount needed for humidity control). The remaining return air is bypassed around the coil, if done at the air handler, and mixed with the cool primary air to produce supply air of the proper temperature and humidity before being delivered directly into the underfloor plenum. In this configuration, a range of coil temperatures can be produced, including low temperature air systems with or without ice storage. An alternative bypass configuration involves recirculating some of the return air directly back into the underfloor plenum where it is mixed with the cool primary air from the air handler. In this case, it is very important to ensure thorough mixing of primary and return air in the plenum. In less humid climates, the warmer supply air temperatures increase the potential for economizer use and may also allow higher cooling coil temperatures to be used, thereby increasing chiller efficiencies. A variety of operating strategies have been used in existing installations. A preferred method for interior zones is constant air volume, variable temperature (CAV-VT). Supply temperature is controlled based on zone thermostats. Occupants can make minor changes to local comfort conditions by adjusting a diffuser. Due to temperature stratification that naturally occurs with UFAD systems, thermostats should be carefully placed and their readings correlated with acceptable comfort conditions in the occupied zone. For example, if stratification is large, an acceptable temperature at the fivefoot level may in fact coincide with uncomfortably cool temperatures at the ankle level. While the floor supply system is very well matched to the stable load profiles in most interior building zones, it is incompatible with the more rapidly varying loads found in perimeter and other special zones. These zones require a separate system, or at least a hybrid solution in which fan-powered outlets and/or additional equipment are used to address the extra heating and cooling requirements of these zones. Perimeter zone operation can be either variable air volume (VAV) or CAV-VT, but in either case must be able to respond to the special cooling and heating demands of these zones. Perimeter zone solutions have not been standardized in existing UFAD installations; many different approaches have been used. 12B. Thermal storage control strategies Since supply air flowing through the underfloor plenum is in direct contact with the concrete floor slab of the building, control strategies must consider thermal storage in the slab as well as other mass in the plenum (e.g., floor panels). UFAD systems are very stable in operation with only gradual (usually unnoticeable to occupants) changes in supply temperature over time, unless the supply air is isolated from the mass. Energy and operating cost savings can be achieved using a thermal storage strategy in the concrete slab. In temperate climates, cool nighttime air can be brought into the underfloor plenum where it effectively cools the slab overnight. During the following day's cooling operation, higher supply air temperatures can be used to meet the cooling demand, thereby reducing refrigeration loads for at least part of the day. This 24-hour thermal storage strategy benefits from lower off-peak utility rates and extends the hours of economizer operation. For this strategy to be successful, the following issues must be addressed: Heating night setback must be used. Since a precooled slab will be at its coolest temperature in the morning, the design, capacity, and response rate of the heating system, if needed, will be particularly important under morning startup conditions. Enthalpy-based economizer control must be used to maintain proper humidity levels of the incoming nighttime air and to protect against condensation in the plenum. Lower limit control switches for both slab and space temperatures must be activated to prevent overcooling. Preliminary estimates indicate that a precooled slab is most effective at reducing daytime cooling loads during morning hours only. If the slab is not pre-cooled at night, then supply outlet temperatures will likely increase with distance from the primary air inlet to the plenum due to the effects of stored heat in the slab (particularly from warm return air from the next floor down flowing along the underside of the slab). CBE is currently conducting research to investigate the thermal storage performance of underfloor air supply plenums.

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP research journal 2013 / VOL 05.01 www.perkinswill.com SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP ARCHITECTURE AND ENGINEERING OF SUSTAINABLE BUILDINGS Current Trends in Low-Energy HVAC Design

More information

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas Methods for Effective Room Air Distribution Dan Int-Hout Chief Engineer, Krueger Richardson, Texas Agenda Overview LEED issues and Update Perimeter Acoustics Thermal Comfort IAQ / Standard 62.1 Update

More information

HVAC Systems: Overview

HVAC Systems: Overview HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct

More information

Comparing Energy Savings of Different VAV Systems

Comparing Energy Savings of Different VAV Systems Comparing Energy Savings of Different VAV Systems Prepared By: Martyn Dodd mart@energysoft.com EnergySoft LLC 1025 5th Street, Suite A Novato, CA 94945 415-897-6400 www.energysoft.com Last Modified: March

More information

Glossary of HVAC Terms

Glossary of HVAC Terms Glossary of HVAC Terms Heating, Ventilation and Air Conditioning (HVAC) is a major sub- discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other

More information

Tate s Wire & Cable Solution

Tate s Wire & Cable Solution Access Floors Tate s Wire & Cable Solution A Flexible & Sustainable Management System Access Flooring to the Power of Your company will discover complete flexibility and reconfiguration capability 2 Creating

More information

Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone. www.titus-hvac.com

Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone. www.titus-hvac.com Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION k-12 education Redefine your comfort zone. www.titus-hvac.com woodgrains dual-function energy solutions table of contents The CBAL-24 is

More information

UNDER FLOOR AIR DISTRIBUTION (UFAD) SOLUTIONS

UNDER FLOOR AIR DISTRIBUTION (UFAD) SOLUTIONS UNDER FLOOR AIR DISTRIBUTION (UFAD) SOLUTIONS OVERHEAD SYSTEM UFAD SYSTEM ...... - A product of AirFixture USA I DON T CARE ZONE B R E A T H I N G Z O N E W E L L M I X E D CONSTANT VOLUME DIFFUSER WITH

More information

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME) SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME) Construction Criteria The unit costs for ADP Mainframe space types are based on the construction quality and design features in the following

More information

Challenges and Failures in Green Building Design Using Under-Floor Air Distribution. Ken Urbanek, PE, HBDP, LEED AP Director of Engineering

Challenges and Failures in Green Building Design Using Under-Floor Air Distribution. Ken Urbanek, PE, HBDP, LEED AP Director of Engineering Challenges and Failures in Green Building Design Using Under-Floor Air Distribution Ken Urbanek, PE, HBDP, LEED AP Director of Engineering Agenda UFAD Overview Challenges / Failures Steps for a Successful

More information

ASTACEA4 Inspect complex/central air conditioning systems

ASTACEA4 Inspect complex/central air conditioning systems Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air

More information

SECTION EG. Engineering Guide Air Distribution. Please refer to the Price Engineer s HVAC Handbook for more information on Air Distribution.

SECTION EG. Engineering Guide Air Distribution. Please refer to the Price Engineer s HVAC Handbook for more information on Air Distribution. SECTION EG Air Distribution Please refer to the Price Engineer s HVAC Handbook for more information on Air Distribution. Space Air Diffusion AIR DISTRIBUTION ENGINEERING GUIDE Proper selection of air diffusion

More information

UNDERFLOOR AIR DISTRIBUTION

UNDERFLOOR AIR DISTRIBUTION FINAL REPORT NCEMBT-080801 UNDERFLOOR AIR DISTRIBUTION AN EXPERIMENTAL COMPARISON OF AIR DIFFUSION PERFORMANCE BETWEEN UNDERFLOOR AIR DISTRIBUTION AND CONVENTIONAL OVERHEAD AIR DISTRIBUTION SYSTEMS AUGUST

More information

Integrated Solar Radiant Systems

Integrated Solar Radiant Systems Integrated Solar Radiant Systems William Shady PE President Topics Radiant heating Indoor air quality Radiant Cooling Project Photos Questions and answers The goal for our clients Healthy Comfort Why Radiant

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment The heating, ventilation and cooling loads of typical commercial office space can range

More information

Mechanical Systems Proposal revised

Mechanical Systems Proposal revised Mechanical Systems Proposal revised Prepared for: Dr. William Bahnfleth, Professor The Pennsylvania State University, Department of Architectural Engineering Prepared by: Chris Nicolais Mechanical Option

More information

ENHANCED LABORATORY HVAC SYSTEM

ENHANCED LABORATORY HVAC SYSTEM ENHANCED LABORATORY HVAC SYSTEM INTRODUCTION Since the early 1980's the attention to more energy efficient laboratory designs has been on the rise due to the increase in energy cost and the emergence of

More information

- White Paper - Data Centre Cooling. Best Practice

- White Paper - Data Centre Cooling. Best Practice - White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH

More information

Pool Dehumidification Basics

Pool Dehumidification Basics Copyright 2009 Wescor. All rights reserved. Permission granted to reproduce for personal and educational use only. When energy costs were low, many pool owners considered only first cost when choosing

More information

HVAC Characteristics. Test Space HVAC Characteristics

HVAC Characteristics. Test Space HVAC Characteristics HVAC Characteristics Information on the characteristics of the heating, ventilation, and air conditioning (HVAC) system(s) in the entire BASE building including types of ventilation, equipment configurations,

More information

Bring the fresh in. Dedicated Outside Air Systems

Bring the fresh in. Dedicated Outside Air Systems Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health

More information

Center for the Built Environment UC Berkeley

Center for the Built Environment UC Berkeley Center for the Built Environment UC Berkeley Peer Reviewed Title: Analysis of a hybrid UFAD and radiant hydronic slab HVAC system Author: Raftery, Paul, National University of Ireland Galway Lee, Kwang

More information

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB

More information

AIR DISTRIBUTION FOR COMFORT AND IAQ

AIR DISTRIBUTION FOR COMFORT AND IAQ AIR DISTRIBUTION FOR COMFORT AND IAQ Heating Piping and Air Conditioning March 1998 Dan Int-Hout Chief Engineer KRUEGER EXCELLENCE IN AIR DISTRIBUTION Modern environmentally controlled spaces consume significant

More information

Displacement ventilation

Displacement ventilation General The displacement ventilation principle is the oldest form of ventilation and can be achieved without the use of fans. Air movement occurs by means of the density differences between supply air

More information

Choosing Close-Coupled IT Cooling Solutions

Choosing Close-Coupled IT Cooling Solutions W H I T E P A P E R Choosing Close-Coupled IT Cooling Solutions Smart Strategies for Small to Mid-Size Data Centers Executive Summary As high-density IT equipment becomes the new normal, the amount of

More information

Acoustic Design Practices for Sustainable Buildings

Acoustic Design Practices for Sustainable Buildings Acoustics 2008 Geelong, Victoria, Australia 24 to 26 November 2008 Acoustics and Sustainability: How should acoustics adapt to meet future demands? Acoustic Design Practices for Sustainable Buildings Danny

More information

Answers to Your Questions from the Webinar

Answers to Your Questions from the Webinar 2008 Desert Aire and USA Swimming. Used by permission. Desert Aire & USA Swimming - Aquatics Webinar - Answers to Your Questions Answers to Your Questions from the Webinar Thank you for your interest in

More information

Innovent LASER Packaged Fresh Air Conditioning Units

Innovent LASER Packaged Fresh Air Conditioning Units LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent

More information

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free... Solar air collectors for industry and larger halls N S Ø Efficient dehumidification and air heating for free... This booklet contains information about SolarVenti Industrial air solar system. The system

More information

Building Energy Systems. - HVAC: Heating, Distribution -

Building Energy Systems. - HVAC: Heating, Distribution - * Some of the images used in these slides are taken from the internet for instructional purposes only Building Energy Systems - HVAC: Heating, Distribution - Bryan Eisenhower Associate Director Center

More information

Displacement Ventilation in Schools

Displacement Ventilation in Schools Displacement Ventilation in Schools Price Displacement Ventilation in Schools Introduction Displacement Ventilation (DV) originated in industrial facilities in Europe as an effective way to remove contaminants

More information

Mechanical and Natural Ventilation

Mechanical and Natural Ventilation BBSE3006: Air Conditioning and Refrigeration II http://www.hku.hk/bse/bbse3006/ Mechanical and Natural Ventilation Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong E-mail:

More information

The Integrated Design Process

The Integrated Design Process The Integrated Design Process The Integrated Design Process (IDP) has been developed on the basis of experience gained from a small Canadian demonstration program for high-performance buildings, the C2000

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers Energy Efficiency Opportunities in Federal High Performance Computing Data Centers Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory

More information

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010 EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a

More information

Suspended ceiling or open plenum?

Suspended ceiling or open plenum? CI/SfB (35) Xy 04/2015 Suspended ceiling or open plenum? Making the right choice. Recent studies illustrate the positive impact of suspended ceilings on life cycle costs, fire safety and the acoustic environment.

More information

Molds and mildew are fungi that grow

Molds and mildew are fungi that grow Appendix C: Moisture, Mold and Mildew Molds and mildew are fungi that grow on the surfaces of objects, within pores, and in deteriorated materials. They can cause discoloration and odor problems, deteriorate

More information

Thermal Mass Availability for Cooling Data Centers during Power Shutdown

Thermal Mass Availability for Cooling Data Centers during Power Shutdown 2010 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Published in ASHRAE Transactions (2010, vol 116, part 2). For personal use only. Additional reproduction,

More information

Active & Passive Beams

Active & Passive Beams Active & Passive Beams Active & Passive Beams Introduction Beam systems are an alternative to traditional all-air conditioning systems. Beams use water to move energy through a building and service the

More information

Fläkt Woods Building Future

Fläkt Woods Building Future Energy, Expertise and Environment with Fläkt Woods Fläkt Woods Building Future Saving energy in building ventilation You must save 20% on energy before 2020. Following the Kyoto protocol the European Union

More information

Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial

Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial facilities commonly occupy spaces with ceilings ranging between twenty and thirty feet in height.

More information

Key energy-efficient features of your new home

Key energy-efficient features of your new home Key energy-efficient features of your new home Your thermal envelope The thermal envelope, or shell, of your home (walls, roof and floor) is designed to keep you dry and comfortable. It protects you from

More information

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Dealing with Thermal Issues in Data Center Universal Aisle Containment Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe Daniele.Tordin@Panduit.com AGENDA Business Drivers Challenges

More information

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

AIR-SITE GROUP. White Paper. Green Equipment Room Practices AIR-SITE GROUP White Paper Green Equipment Room Practices www.air-site.com Common practices to build a green equipment room 1 Introduction Air-Site (www.air-site.com) is a leading international provider

More information

CONDENSATION IN REFRIDGERATED BUILDINGS

CONDENSATION IN REFRIDGERATED BUILDINGS CONDENSATION IN REFRIDGERATED BUILDINGS By: Steve Salisbury Nov. 10, 2010 (revised Nov. 14, 2013) Introduction The following discussion reviews the basic causes of condensation in refrigerated buildings

More information

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES Department of Health and Human Services, Division of Public Health Occupational and Environmental Epidemiology Branch 1912 Mail Service Center, Raleigh, North Carolina 27699-1912 BUILDING ASSESSMENT QUESTIONNAIRE

More information

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION 3.1 Purpose of Thermal Load Estimation 3.2 Heating Load versus Cooling Load 3.3 Critical Conditions for Design 3.4 Manual versus Computer Calculations 3.5 Heating

More information

The Future is Raised Access Floors

The Future is Raised Access Floors Access Floors CI/SfB (33.1) X June 2008 The Future is Raised Access Floors Low Energy - Low Carbon Buildings SYSTEM CERTIFICATION SYSTEM CERTIFICATION ISO 9001:2000 ISO SGS 14001 SGS Kingspan Access Floors

More information

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple CHAPTER SEVEN L. Glicksman and J. Lin (eds), Sustainable Urban Housing in China, 116-123 2006 Springer. Printed in the Netherlands. DESIGN OF NATURAL VENTILATION WITH CFD Qingyan Chen INTRODUCTION As the

More information

L EED & G r e e n B u i ldi ngs

L EED & G r e e n B u i ldi ngs L EED & G r e e n B u i ldi ngs A P P L I C AT I O N G U I D E contents 3 - General 3 - Introduction 3 - Leadership in Energy & Environment 3 - Purpose 3 - LEED Rating System 4 - Energy & Atmosphere 4

More information

Hospital Application Guide. Cost-effective climate control for hospitals

Hospital Application Guide. Cost-effective climate control for hospitals Hospital Application Guide Cost-effective climate control for hospitals Munters is the world leader in dehumidification Munters is the largest manufacturer of dehumidifiers in the world. Since developing

More information

underfloor air distribution

underfloor air distribution hospitals fire rated woodgrains energy solutions Redefine your comfort zone. www.titus-hvac.com Table of Contents products UnderFloor Air Distribution Products... 4 overview Application Guide... 8 Introduction

More information

The Different Types of Air Conditioning Equipment for IT Environments

The Different Types of Air Conditioning Equipment for IT Environments The Different Types of Air Conditioning Equipment for IT Environments By Tony Evans White Paper #59 Executive Summary Cooling equipment for an IT environment can be implemented in 10 basic configurations.

More information

Radiant Panels and Chilled Sails. www.price-hvac.com

Radiant Panels and Chilled Sails. www.price-hvac.com Radiant Panels and Chilled Sails www.price-hvac.com Radiant Panels and Chilled Sails Introduction Radiant panels use thermal radiation to modify surface temperatures in order to provide sensible cooling

More information

Adaptive strategies for office spaces in the UK climate

Adaptive strategies for office spaces in the UK climate International Conference Passive and Low Energy Cooling 631 Adaptive strategies for office spaces in the UK climate I. Gallou Environment & Energy Studies Programme, Architectural Association Graduate

More information

ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests

ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests DesignBuilder Version 1.2.0 (incorporating EnergyPlus version 1.3.0) - June 2006 1.0 Purpose The ANSI/ASHRAE Standard 140-2004

More information

SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION The purpose of this guide specification is to assist the specifier in correctly specifying Mechanical System Testing

More information

HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J.

HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J. Reducing Building HVAC Costs of site rec By Stephen J. Pargeter Building owners are caught between two powerful forces the need to lower energy costs and the need to meet or exceed outdoor air ventilation

More information

plenum slot diffusers

plenum slot diffusers light powered Redefine your comfort zone. www.titus-hvac.com dual-function smart logic light powered energy solutions Table of Contents PLENUM SLOT IFFUSERS products Plenum Slot iffusers Products... 4

More information

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001 Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001 Presented by: Liberty Engineering, LLP 1609 Connecticut Avenue

More information

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES

More information

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY Construction Criteria The unit costs for (Wet) space types are based on the construction quality and design features in the following table. This

More information

CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning)

CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning) CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning) Objectives Survey current HVAC system(s), operating procedures, and maintenance schedule. Analyze results of energy audit for HVAC system(s)

More information

Basic Selection & Proper Application of Overhead Air Distribution Devices

Basic Selection & Proper Application of Overhead Air Distribution Devices Basic Selection & Proper Application of Overhead Air Distribution Devices GRD Selection & Application Terms Selection Throw Sound Installation Variations affect Performance Inlet Effects Basics Return

More information

DUCT SYSTEM DESIGN CONSIDERATIONS Part 1

DUCT SYSTEM DESIGN CONSIDERATIONS Part 1 Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 DUCT SYSTEM DESIGN CONSIDERATIONS Part 1 by Roger M Hensley, CMS TYPES OF SUPPLY DUCT SYSTEMS There are several basic

More information

UDSA - UDSBD unit heater

UDSA - UDSBD unit heater APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the

More information

Case Studies: Infrared Heating in Industrial Applications

Case Studies: Infrared Heating in Industrial Applications Case Studies: Infrared Heating in Industrial Applications Chao Chen, Puget Sound Energy ABSTRACT Puget Sound Energy (PSE) is a utility which serves more than one million electric customers and over 700,000

More information

LITERATURE REVIEW OF FLEXIBLE AND ADAPTIVE HVAC DISTRIBUTION SYSTEMS FOR OFFICE BUILDINGS. Xin Yu and Theodore F. Smith

LITERATURE REVIEW OF FLEXIBLE AND ADAPTIVE HVAC DISTRIBUTION SYSTEMS FOR OFFICE BUILDINGS. Xin Yu and Theodore F. Smith LITERATURE REVIEW OF FLEXIBLE AND ADAPTIVE HVAC DISTRIBUTION SYSTEMS FOR OFFICE BUILDINGS Xin Yu and Theodore F. Smith Department of Mechanical Engineering The University of Iowa Iowa City, Iowa 52242

More information

VAV Laboratory Room Airflow The Lowdown on Turndown

VAV Laboratory Room Airflow The Lowdown on Turndown Technology Report March, 2003 VAV Laboratory The Lowdown on Turndown Turndown comparison of these two turndown ratios. Note the small actual airflow difference between them. control ranges are normally

More information

Mistrale. Fusion Terminal

Mistrale. Fusion Terminal Mistrale Fusion Terminal PUBLICATION NATURAL VENT. 1 SEPT 2015 Features - Slimline energy efficient ventilation solution - Standard and high capacity terminals provide 128 or 256 L/s capacity - Compliant

More information

A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses

A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses Robert L Crosby Jr, Biorealis Systems, Inc. Abstract: Bristol Bay Housing Authority (BBHA) currently

More information

How To Make A Building Energy Efficient

How To Make A Building Energy Efficient An Introduction to Chilled Beams and Ceilings July 2012 Version 1 DISCLAIMER All rights reserved. Apart from any fair dealing for the purposes of private study or research allowed under applicable copyright

More information

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL

More information

Air-water systems for efficient air conditioning

Air-water systems for efficient air conditioning Air-water systems for efficient air conditioning The art of handling air System overview Passive cooling systems Induction units Façade ventilation units Page 4 Page 6 Page 10 Passive Chilled ceiling Undersill

More information

Comparison between Decentralised and Centralised Air Conditioning Systems

Comparison between Decentralised and Centralised Air Conditioning Systems Comparison between De and Centralised Air Conditioning Systems (Summary) FassadenSystemLüftung FassadenSystemLüftung Telephone +49/ 28 45/ 2 02-711 GmbH & Co KG Telefax +49/28 45/2 02-2 25 Heinrich-Trox-Platz

More information

Suspended ceiling or open plenum? Making the right choice.

Suspended ceiling or open plenum? Making the right choice. CEILING SYSTEMS Between us, ideas become reality Recent studies illustrate the positive impact of suspended ceilings on life cycle costs, fire safety, and the acoustic environment Suspended ceiling or

More information

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues Design Guide Retrofitting Options For HVAC Systems In Live Performance Venues Heating, ventilation and air conditioning (HVAC) systems are major energy consumers in live performance venues. For this reason,

More information

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS William K. Scullion, Application Engineering Leader, MEGTEC Systems, De Pere, WI Introduction Competitive pressures continuously motivate us to examine our

More information

MULTIZONE APPLICATION OF SOLUTION UNITS

MULTIZONE APPLICATION OF SOLUTION UNITS MULTIZONE APPLICATION OF SOLUTION UNITS APPLICATION GUIDE Supersedes: 102.20-AG12 (206) Form: 102.20-AG12 (307) GENERAL Multi-zone heating and air conditioning units offer design and application advantages

More information

Topics for Today. Order of Magnitude Mechanical Estimating. Order of Magnitude Estimate Goal. Project Delivery Methods. Questions for Client

Topics for Today. Order of Magnitude Mechanical Estimating. Order of Magnitude Estimate Goal. Project Delivery Methods. Questions for Client Order of Magnitude Mechanical Estimating Justin Apprill, P.E. Topics for Today Estimate Goals A Concept for Accurate Conceptual Estimating HVAC Systems Common System Types and Rules of Thumb Pricing Example

More information

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs

More information

ENERGY AUDIT IN THE KACST BUILDING

ENERGY AUDIT IN THE KACST BUILDING ENERGY AUDIT IN THE KACST BUILDING S. M. Hasnain, S. H. Alawaji, A. M. Al-Ibrahim and S. M. Smiai Energy Research Institute (ERI) King Abdulaziz City for Science and Technology (KACST) P.O. Box 6086, Riyadh

More information

APC APPLICATION NOTE #112

APC APPLICATION NOTE #112 #112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.

More information

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same

More information

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions

More information

Dehumidification Design

Dehumidification Design Dehumidification Design Using Data-Center Heat Utilizing free heat from a server room was the concept behind an air-handling system in a college-campus building Considerable energy savings are possible

More information

How To Improve Energy Efficiency Through Raising Inlet Temperatures

How To Improve Energy Efficiency Through Raising Inlet Temperatures Data Center Operating Cost Savings Realized by Air Flow Management and Increased Rack Inlet Temperatures William Seeber Stephen Seeber Mid Atlantic Infrared Services, Inc. 5309 Mohican Road Bethesda, MD

More information

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01 GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per

More information

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings Advanced Energy Design Guide LEED Strategies for Schools and High Performance Buildings Today s Presenters Stephen Koontz, LEED AP Energy Services Leader Tampa Bay Trane Allen Irvine General Sales Manager

More information

Venice Library Humidity Study. for Williams Building Diagnostics, LLC 305 15 th Street West Bradenton, FL 34205. Report April 13, 2015

Venice Library Humidity Study. for Williams Building Diagnostics, LLC 305 15 th Street West Bradenton, FL 34205. Report April 13, 2015 for Williams Building Diagnostics, LLC 305 15 th Street West Bradenton, FL 34205 Report April 13, 2015 Moses & Associates, Inc. 2209 NW 40 th Terrace, Suite A Gainesville, FL 32605 FL License EB-0003097

More information

Design Options for HVAC Distribution Systems

Design Options for HVAC Distribution Systems Design Options for HVAC Distribution Systems Course No: M06-017 Credit: 6 PDH A. Bhatia Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800 F: (877)

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

Cooling Strategies for IT Wiring Closets and Small Rooms

Cooling Strategies for IT Wiring Closets and Small Rooms Cooling Strategies for IT Wiring Closets and Small Rooms By Neil Rasmussen Brian Standley White Paper #68 Executive Summary Cooling for IT wiring closets is rarely planned and typically only implemented

More information

POWER DISTRIBUTION. Power and Undercarpet Products POWER AND UNDERCARPET PRODUCTS. Chapter Summary

POWER DISTRIBUTION. Power and Undercarpet Products POWER AND UNDERCARPET PRODUCTS. Chapter Summary Power and Undercarpet Products POWER AND UNDERCARPET PRODUCTS AMPINNERGY Modular Power Distribution System................... 270 Raised Access Floor/Zone Wiring Distribution System................ 270

More information

engineers newsletter air distribution Cold Air Makes Good $ense Benefits of Cold Air How Cold Is Cold?

engineers newsletter air distribution Cold Air Makes Good $ense Benefits of Cold Air How Cold Is Cold? engineers newsletter providing insights for today s hvac system designer air distribution Cold Air Makes Good $ense from the editor Since 1995, the Engineers Newsletter has examined various aspects of

More information

Flexibility, Efficiency In San Antonio Arena

Flexibility, Efficiency In San Antonio Arena 2005, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Reprinted by permission from ASHRAE Journal, (Vol. 47, No. 9, September 2005). This article may not

More information

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce

More information