1 (800) Fax: (8) Helgesen Drive Madison, Wisconsin USA In CANADA (905) Fax: (905) In MEXICO, CENTL and SOUTH AMERICA and the CARIBBN 5 () Fax: 5 ()

2 Energy Recovery Ventilation: the proven advantages of heat and humidity transfer Improves Indoor Air Quality By providing simultaneous exhaust and fresh air supply, RenewAire reduces the concentration of harmful pollutants in indoor air - an absolute must in schools, offices and smoking environments. Meets Ventilation Codes for Air Exchange Provides ample ventilation to meet ASHE 6 and the International Mechanical Code that now requires two to three more air exchanges than in the past. Indoor Air Quality Problems Solved! Controls Excess Moisture Unlike conventional ventilation or basic heat exchangers, RenewAire moderates not only the temperature but the humidity content of incoming air, limiting humidity swings and associated biologic growths. Optimum Cold Weather Performance Recaptures heat otherwise lost to exhaust air while controlling humidity extremes. This greatly reduces the demand on heating equipment - lowering both initial costs and energy bills. Also protects heating coils from freeze damage. Optimum Warm Weather Performance Pre-cools and dehumidifies the fresh airstream by transfer of heat and humidity to the exhaust airstream. This greatly reduces air conditioning demand - lowering both initial costs and energy bills. On retrofits, the ventilation rate of exisitng A/C equipment can be as much as doubled. Energy Saved = Dollars Saved RenewAire s all-weather performance can cut annual energy bills for heating, cooling and dehumidification of ventilation air by 50% or more. Ideal for Hot or Cold Environments Catalog Page Reference Residential Products 4 BR70 5 BR130 6 EV70 7 EV130 8 EV00 9 EV Commercial Indoor Products 1 EV450IN 14 HE1XINH 16 HE1XINV 18 HEXINH 0 HEXINV HE3XINH 4 HE3XINV 6 HE4XINH 8 HE4XINV 30 HE6XIN 3 HE8XIN 34 Commercial Outdoor Products 36 EV450RT 38 HE1XRT 40 HE1XRTC 4 HEXRT 44 HEXRTC 46 HE3XRT 48 HE3XRTC 50 HE4XRT 5 HE4XRTC 54 HE6XRT 56 HE8XRT 58 Applied Products CA-Series 6 PA-Series 64 Commercial Controls 66 HVI Certified 67 AHRI Certified 67 CA/PA Model Number Guide 68 EV/HE Model Number Guide 69 Company History For Technical Support Support@RenewAire.com To Place an Order RenewAireOrders@RenewAire.com

3 Why RenewAirE? INSIDE Fresh Air to Room Fixed Partition and Spacer Plates (proprietary resin composite media) Stale Room Air G5 OUTSIDE Stale Room Air (exhausted to outside) Outside Air Enhanced Humidity Transfer RenewAire is proud to introduce the fifth generation energy recovery ventilation (ERV) core. Over % more humidity transfer at AHRI summer conditions reduced pressure drop - among the lowest for static-plate ERV HE1X = 750 SCFM EV450 = 450 SCFM Try RenewAire s ERV Calculation Software at RenewAire s remarkable performance is independently certified by: The Static-Plate Core is the Key! Since the early 1980 s, RenewAire has pioneered the use of the patented Lossnay (Registered trademark of Mitsubishi Electric Corporation) exchange core throughout the Americas. Listed below are some of the many reasons why this technology has become the ERV system preferred by leading HVAC professionals around the world. Positive Airstream Separation In the RenewAire core, fresh air never comes in contact with exhaust air passages. Hydroscopic resin plates separate the two airstreams so effectively that AHRI certifies zero exhaust air transfer at normal, balanced operating conditions. As a result, RenewAire is perfect for controlled exhaust applications such as toilet areas, as well as for food service and health care occupancies. No Condensate or Active Defrost Direct water vapor transfer, driven by vapor pressure, eliminates condensation - and frosting - in virtually all applications and climate zones. No condensation allows for closer plate spacing, resulting in higher efficiencies and easier installations. It also means no need for the dampers or electrical defrost elements that reduce ventilation and rob energy efficiency in competing technologies. Maintenance - Nothing Could Be Easier The scheduled maintenance for RenewAire is so simple, it can be performed by any janitorial staff. No expensive service contracts are necessary because there is no wheel disassembly and washing, no seal or belt adjustments and no complex controls to calibrate. The result is the lowest maintenance cost of any ERV. The Unbeatable RenewAire Warranty An investment in RenewAire is protected by a 10-year core warranty ( years on balance of the unit). This commitment - twice as long as coverage on the best wheel products - speaks volumes about RenewAire s reliability, durability and consistently high performance. Award-Winning Service and Support RenewAire s team of professionals knows ERV. And our nationwide network of Sales Reps and quality Distributors are ready to serve you locally. When you call our support number, you ll talk to a knowledgeable factory expert - someone who knows not only our product line, but the best ways to integrate RenewAire with your preferred lines of heating and air conditioning equipment.

4 Residential/Small Commercial Products Commercial quality, ducted equipment sized to meet required ventilation rates for homes and small commercial buildings. Static-plate technology makes total energy savings practical for small-capacity systems. May be mounted in any orientation. Quiet, powerful blowers eliminate the need for air balancing in most applications. Positive airstream separation that is critical for smoking environments and bathroom exhaust. No condensate pan or drain required. Easiest maintenance of any ERV. Performance certified by HVI. Ten year core warranty. Central Exhaust - Use EV Series : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside NOTE: ERV Blower may be operated separately from Furnace Blower General Exhaust - EV Series (or BR Series mounted to furnace return air which requires furnace blower interconnect) (See manual for additional installation methods.) NOTE: ERV Blower may be operated separately from Furnace Blower PTL Control primary control for EV70, EV130, EV00 & EV300 runs unit an adjustable amount of time each hour two wire, low voltage connection to ERV PBL Control push button control turns on unit from bathrooms or other intermittent exhaust locations 0 minute run-time with one touch push x for 40 or 3x for minutes two wire, low voltage connection to PTL Control FM Control alternate primary control for EV70, EV130, EV00 & EV300 wires to EV unit and either thermostat or furnace control to turn on furnace blower six wire, low voltage connection (800) Fax: (8) 1-84

5 Residential Energy Recovery Ventilators: BR70, BR130, EV70, EV130, EV00 and EV300 Part I - General A. Product Specification 1. Energy Recovery Ventilator (ERV) shall be a packaged unit as manufactured by RenewAire and shall transfer both heat and humidity using static plate core technology. B. Quality Assurance 1. The energy recovery ventilator shall be Certified by the Home Ventilating Institute (HVI) under CSA 439. Both a heating and a cooling test must be run to demonstrate year round energy recovery.. Manufacturer shall be able to provide evidence of independent testing of the core by Underwriters Laboratory (UL), verifying a maximum flame spread index (FSI) of 5 and a maximum smoke developed index (SDI) of 50 thereby meeting NFPA 90A and NFPA 90B requirements for materials in a compartment handling air intended for circulation through a duct system. The method of test shall be UL Standard Unit shall be Listed under UL 181 Standard for Ducted Air to Air Heat Exchangers. The unit must pass commercial flammability requirements and shall not be labeled For Residential Use Only. 4. The ERV core shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of ten years from the date of purchase. The balance-of-unit shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of two years from the date of purchase. Part II Performance A. Energy Transfer The ERV shall be capable of transferring both sensible and latent energy between airstreams. Latent energy transfer shall be accomplished by direct water vapor transfer from one airstream to the other, without exposing transfer media in succeeding cycles directly to the exhaust air and then to the fresh air. B. Passive Frost Control The ERV core shall perform without condensing or frosting under normal operating conditions (defined as outside temperatures above -10 F and inside relative humidity below 40%). Occasional more extreme conditions shall not affect the usual function, performance or durability of the core. No condensate drains will be allowed. C. Continuous Ventilation Unit shall have the capacity to operate continuously without the need for bypass, recirculation, pre-heaters or defrost cycles under normal operating conditions. D. Positive Airstream Separation Water vapor transfer shall be through molecular transport by hydroscopic resin and shall not be accomplished by porous plate mechanisms. Exhaust and fresh airstreams shall travel at all times in separate passages and airstreams shall not mix. E. Laminar Flow Airflow through the ERV core shall be laminar over the products entire operating airflow range, avoiding deposition of particulates on the interior of the energy exchange plate material. Part III Product A. Construction 1. The energy recovery component shall be of fixed-plate cross-flow construction, with no moving parts.. No condensate drain pans or drains shall be allowed and unit shall be capable of operating in both winter and summer conditions without generating condensate. 3. The unit case shall be constructed of 4-gauge steel, with lapped corners and zinc plated screw fasteners. The case shall be finished with textured, powder coat paint. 4. Access doors shall provide easy access to blowers, ERV cores and filters. Doors shall have an airtight compression seal using closed cell foam gaskets. 5. Case walls and doors shall be fully insulated with 1 inch, expanded polystyrene foam insulation faced with a cleanable foil face on all exposed surfaces. 6. The ERV cores shall be protected by a MERV-8 rated, spun polyester, disposable filter in both airstreams. 7. The unit shall have a line cord power connection and be supplied with an internal 4 VAC transformer and relay. 8. Standby power draw shall not exceed 1 Watt for the unit along with an optional automatic control. B. Options (Select options based on application requirements) 1. For BR-Series: Through the wall kit and duct collar kit (automatic control is built into the unit standard).. For EV-Series: Controls including proportional run time, push button and furnace interlock and a variety of weather hoods. Part IV Installation A. Unit Location 1. Locate and orient unit to provide the shortest and most straight duct connections. Provide service clearances as indicated on the plans. Locate units distant from sound critical occupancies.. Use integral mounting flange and hanging bar system to mount the unit to a structurally suitable surface. The units may be mounted in any orientation. B. Vibration Isolation 1. Utilize factory supplied vibration isolation kit following instructions.. Provide flexible duct connections at unit duct flanges. C. Duct Design 1. All ductwork shall be designed, constructed, supported and sealed in accordance with SMACNA HVAC Duct Construction Standards and pressure classifications.. At a minimum all duct runs to the outdoors shall be thermally insulated at levels appropriate to the local climate. A continuous vapor barrier shall also be provided on warm surface of the insulation. D. Sound Control 1. To control sound radiated from the unit: a. Provide acoustic treatment in mechanical room walls and ceilings.. To control sound associated with the two blower outlets: a. Utilize insulated, flexible duct. b. In sound critical applications provide increased duct sizing and consider the use of sound attenuators. E. Test and Balancing 1. Test and Balancing may not begin until 100% of the installation is complete and fully functional.. Follow National Comfort Institute (NCI) air test and balance procedures specific to Heat Recovery Ventilator Balancing Procedure including standard reports to the owner s representative. 3

6 BR70 Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: CFM Number Motors: One, 0.08 hp V HZ Phase Input Watts FLA 10 Single 69 CFM 0.9 Control Voltage: 4 VAC Filters: MERV 8, spun polyester media. 7 1/ x 10 1/ x 1 Weight: 39 lbs (unit), 50 lbs (in carton) Shipping Dimensions: 1 1/ W x 9 L x 14 1/ H G4 Performance Airflow CFM ESP in H0 Temp EFF% Total EFF% Winter/Summer* / / / / /45 * (See HVI certification report on page 66 for complete certified rating). Options: Thru-the-Wall Kit Duct Collar Kit Dimensions 1 1/8 (TW) (DH) /8 TOP VIEW (TW) (DH) CUT HOLE IN DUCT (MINIMUM SIZE) : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside TW: Thru Wall DH: Duct Hung (TW) (DH) (TW) (DH) 36" LINE CORD (TW) (DH) (TW) (DH) 10 5/8 6 DIA 8 DIA SIDE VIEW 7 1/8 18 1/4 4 VAC CONTROL TERMINAL PROPORTIONAL RUNTIME CONTROL RIGHT VIEW 18 1/ SERVICE AR 4 1/ 5 4 BOTTOM VIEW (DOOR REMOVED) (800) Fax: (8) 1-84

7 BR130 Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: CFM Unit may be mounted in any orientation Number Motors: One, 0.1 hp V HZ Phase Input Watts FLA 10 Single 14 CFM 1.3 Control Voltage: Built in proportional runtime control and switched terminals for furnace / AC interconnect Filters: MERV 8, spun polyester media. 10 1/ x 10 1/ x 1 G4 Performance Airflow CFM ESP in H0 Temp EFF% Total EFF% Winter/Summer* / / / / / / /41 * (See HVI certification report on page 66 for complete certified rating). Weight: 49 lbs (unit), lbs (in carton) Shipping Dimensions: 1 W x 3 L x 17 1/ H Options: Thru-the-Wall Kit Duct Collar Kit Dimensions (TW) (DH) 6 (TW) (DH) : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside 1 1/8 0 1/ TOP VIEW CUT HOLE IN DUCT (MINIMUM SIZE) TW: Thru Wall DH: Duct Hung (TW) (DH) (TW) (DH) 36" LINE CORD (TW) (DH) 6 1/8 4 3/4 (TW) (DH) 13 3/8 6 DIA 8 DIA SIDE VIEW 30 7/8 4 VAC CONTROL TERMINAL 18 1/ PROPORTIONAL RUNTIME CONTROL SERVICE AR 18 1/4 RIGHT VIEW 4 1/ 5 BOTTOM VIEW (DOOR REMOVED) 5

8 EV70 Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: CFM Unit may be mounted in any orientation Number Motors: One, 0.08 hp V HZ Phase Input Watts FLA 10 Single 69 CFM 0.9 Control Voltage: 4 VAC Filters: MERV 8, spun polyester media. 7 1/ x 10 1/ x 1 Weight: 39 lbs (unit), 48 lbs (in carton) G4 Performance Airflow CFM ESP in H0 Temp EFF% Total EFF% Winter/Summer* / / / /49 * (See HVI certification report on page 66 for complete certified rating). Shipping Dimensions: 1 1/ W x 9 L x 14 1/ H Options: PTL - Percentage Timer Control PBL - Push Button Point-of-Use Controls FM - Percentage Timer Control with Furnace Interlock DH4 - Dehumidistat Control Wall Caps Dimensions 34" Line Cord : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside 4 1/" 9 1/8" 5 1/" TOP VIEW Blowers Interlock Switch 5 1/8" 6" 6" 4 1/8" 8 1/8" Line Cord 4 Volt AC Control Terminal 10 1/8" 8" 6" 0 1/8" 5 1/" Filters Energy Transfer Core 7 7/8" Service Access FRONT VIEW RIGHT VIEW 6 (800) Fax: (8) 1-84

9 EV130 Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: CFM Unit may be mounted in any orientation Number Motors: One, 0.1 hp V HZ Phase Input Watts FLA 10 Single 14 CFM 1. Control Voltage: 4 VAC Filters: MERV 8, spun polyester media. 10 1/ x 10 1/ x 1 Weight: 49 lbs (unit), 58 lbs (in carton) G4 Performance Airflow CFM ESP in H0 Temp EFF% Total EFF% Winter/Summer* / / / / / / /41 * (See HVI certification report on page 66 for complete certified rating). Shipping Dimensions: 1 W x 3 L x 17 1/ H Options: PTL - Percentage Timer Control PBL - Push Button Point-of-Use Controls FM - Percentage Timer Control with Furnace Interlock DH4 - Dehumidistat Control Wall Caps Dimensions 4 1/8" : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside 6 3/8" 34" Line Cord TOP VIEW 13" 9 1/8" 5 1/" Blowers Interlock Switch 8 3/4" 6" 8 1/8" Line Cord 4 Volt AC Control Terminal 8" 6" 0 1/8" 5 1/" 6" Filters Energy Transfer Core 30 5/8" Service Access FRONT VIEW RIGHT VIEW 7

10 EV00 Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: CFM Number Motors: One, 0.1 hp V HZ Phase Input Watts FLA 10 Single 181 CFM 1.5 Control Voltage: 4 VAC Filters: MERV 8, spun polyester media. 10 1/ x 1 3/4 x 1 Weight: 70 lbs (unit), 8 lbs (in carton) Shipping Dimensions: 1 1/ W x 3 L x 9 H G4 Performance Airflow CFM ESP in H0 Temp EFF% Total EFF% Winter/Summer* / / / / / / /5 * (See HVI certification report on page 66 for complete certified rating). Options: PTL - Percentage Timer Control PBL - Push Button Point-of-Use Controls FM - Percentage Timer Control with Furnace Interlock DH4 - Dehumidistat Control Wall Caps Dimensions 11 7/8" 11 7/8" : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside 34" Line Cord 9 1/8" 5 1/" 5 1/" TOP VIEW Interlock Switch Blowers 8 3/4" 6" 6" 8 1/8" Line Cord 4 Volt AC Control Terminal 3 7/8" 8" 6" 0 1/8" 8 Filters Energy Transfer Core FRONT VIEW (800) Fax: (8) /" Service Access RIGHT VIEW

11 EV300 Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: CFM Number Motors: One, 0. hp V HZ Phase Input Watts FLA 10 Single 93 CFM 3.3 Control Voltage: 4 VAC Filters: MERV 8, spun polyester media. 10 1/ x 1 3/4 x 1 Weight: 7 lbs (unit), 85 lbs (in carton) Shipping Dimensions: 1 1/ W x 3 L x 9 H G4 Performance Airflow CFM ESP in H0 Temp EFF% Total EFF% Winter/Summer* / / / / / / /37 * (See HVI certification report on page 66 for complete certified rating). Dimensions 10" 9 3/4" Options: PTL - Percentage Timer Control PBL - Push Button Point-of-Use Controls FM - Percentage Timer Control with Furnace Interlock DH4 - Dehumidistat Control 8 Wall Caps : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside 34" Line Cord TOP VIEW To Fit 8" Duct Interlock Switch Blowers 8 3/4" 4 Volt AC Control Terminal 3 7/8" 8 3/4" 9 1/8" 5 1/" 5 1/" 5 1/" 5 1/" 9 1/8" 7 3/8" 0 1/8" Filters Energy Transfer Core 41 1/" Service Access Line Cord FRONT VIEW RIGHT VIEW 9

12 Commercial INDOOR Products Horizontal and vertical configuration. Wide range of airflow and static capacities. AHRI certified performance data for efficiency and cross leakage. UL tested flammability and smoke generation that meets NFPA 90A and 90B test standards for commercial applications. Easy installation and service. Ten year core warranty. RenewAire means Trouble-Free ERV. : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside 10 (800) Fax: (8) 1-84

13 Packaged Indoor Energy Recovery Ventilators: EV450IN, HE1XIN, HEXIN, HE3XIN, HE4XIN, HE6XIN, HE8XIN Part I - General A. Product Specification 1. Energy Recovery Ventilator (ERV) shall be a packaged unit as manufactured by RenewAire and shall transfer both heat and humidity using static plate core technology. B. Quality Assurance 1. The energy recovery cores used in these products shall be third party Certified by AHRI under its Standard 10 for Energy Recovery Ventilators. AHRI published certifications shall confirm manufacture s published performance for airflow, static pressure, temperature and total effectiveness, purge air (CF) and exhaust air leakage (TR). Products that are not currently AHRI Certified will not be accepted.. Manufacturer shall be able to provide evidence of independent testing of the core by Underwriters Laboratory (UL), verifying a maximum flame spread index (FSI) of 5 and a maximum smoke developed index (SDI) of 50 thereby meeting NFPA 90A and NFPA 90B requirements for materials in a compartment handling air intended for circulation through a duct system. The method of test shall be UL Standard Unit shall be Listed under UL 181 Standard for Ducted Air to Air Heat Exchangers. (Note that a few low volume product or product configurations are not UL Listed.) 4. The ERV core shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of ten years from the date of purchase. The balance-of-unit shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of two years from the date of purchase. Part II Performance A. Energy Transfer The ERV shall be capable of transferring both sensible and latent energy between airstreams. Latent energy transfer shall be accomplished by direct water vapor transfer from one airstream to the other, without exposing transfer media in succeeding cycles directly to the exhaust air and then to the fresh air. B. Passive Frost Control The ERV core shall perform without condensing or frosting under normal operating conditions (defined as outside temperatures above -10 F and inside relative humidity below 40%). Occasional more extreme conditions shall not affect the usual function, performance or durability of the core. No condensate drains will be allowed. C. Continuous Ventilation Unit shall have the capacity to operate continuously without the need for bypass, recirculation, pre-heaters or defrost cycles under normal operating conditions. D. Positive Airstream Separation Water vapor transfer shall be through molecular transport by hydroscopic resin and shall not be accomplished by porous plate mechanisms. Exhaust and fresh airstreams shall travel at all times in separate passages and airstreams shall not mix. Part III Product A. Construction 1. The energy recovery component shall be of fixed-plate cross-flow construction, with no moving parts.. No condensate drain pans or drains shall be allowed and unit shall be capable of operating in both winter and summer conditions without generating condensate. 3. The unit case shall be constructed of G90 galvanized, 0-gauge steel, with lapped corners and zinc plated screw fasteners. 4. Access doors shall provide easy access to blowers, ERV cores and filters. Doors shall have an airtight compression seal using closed cell foam gaskets. 5. Case walls and doors shall be insulated with 1 inch, 4 pound density, foil/scrim faced, high-density fiberglass board insulation, providing a cleanable surface and eliminating the possibility of exposing the fresh air to glass fibers. 6. The ERV cores shall be protected by a MERV-8 rated, nominal, pleated, disposable filter in both airstreams. 7. Unit shall have single-point power connection and a single-point 4 VAC contactor control connection (except Inverter Ready units that have terminal connections for an independent inverter for each airstream). 8. Blower motors shall be EPACT compliant for energy efficiency and be thermally protected or supplied with external starters. 9. Blowers shall be quiet running, forward curve type and be either direct drive or belt drive. HE6X and HE8X units use backward incline, belt drive blower packages. Belt drive motors shall be provided with adjustable pulleys and motor mounts allowing for proper belt tensioning. B. Options (Select options based on application requirements.) 1. Provide unit and duct connection orientation per project schedule.. Provide double wall construction with 4-gauge galvanized steel liner. 3. Units are available single or three phase at a full range of operating voltages. See project schedule. 4. Provide motor horsepower as specified in project schedule. 5. Provide inverter-ready units which include shielded power wiring and terminal connections for inverters (inverters provided and installed by others). 6. Provide factory installed fused disconnects. 7. Provide factory installed non-fused disconnects. 8. Provide factory installed transformer/relay package to supply a 4 VAC power source. 9. Provide factory installed filter monitors for each airstream. E. Laminar Flow Airflow through the ERV core shall be laminar over the products entire operating airflow range, avoiding deposition of particulates on the interior of the energy exchange plate material. 11

14 EV450IN Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: CFM AHRI 10 Certified Core: One L85 Airflow Rating Points (for AHRI): 450 CFM and 338 CFM Motors: One, 0.6 hp (Single Phase) One, 0.5hp ( Phase) V HZ Phase FLA 1 Single 7.0 Single Single.4 G5 Performance Airflow CFM ESP in H0 Watts 1P 3P Temp EFF% Total EFF% Winter/Summer* / / / / / / /50 *At AHRI 10 standard conditions (See certified data on page 67 for core components.) Control Voltage: 4 VAC Filters: Two total, MERV 8, pleated, 14 x 0 nominal size Weight: 141 lbs (unit), 1 lbs (in carton), up to 3 units on 50 lb pallet Shipping Dimensions: 37 1/ W x 48 L x 17 H Options: 45EVHB - Hanging Bracket, Foot Kit 45EVDF - Rectangular 1 x 8 Flange Kit ( in kit) 45EVT10-10 Round Transition Kit ( in kit) 1 (800) Fax: (8) 1-84

15 EV450IN Unit Dimensions Alternate Power Supply Entry 7/8" Dia. 4 3/4" 1/8" : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside 11 5/8" 16 1/8" 0 3/8" 4 7/8" 3 1/4" 5 3/8" 13 1/4" 1" 36 3/8" 3" 35 1/4" 33 7/8" 16 1/8" 0 1/4" 4 1/4" 1 1/4" 10" 36 3/8" 13 1/4" 16" 34 1/8" Service Area 1 1/" Clearance required to remove doors from hinges. Filter Access: Hinged and Latched Door 1/8" 8" 8" 8" 8" 8" TOP VIEW Control Wire Entry 7/8" Dia. Power Supply Entry 7/8" Dia. 1/8" All other Access: 18" Screw-attached panel 44 1/8" FRONT VIEW 6 1/" 10" 6 3/8" 6 1/4" 10 1/8" 8 3/4" 1" O10" ROUND 16 1/8" 0 1/4" 3" 36 3/8" 5 1/8" 3" 16 1/8" 0 1/4" 4 1/4" 11 1/8" 4 1/4" 1/8" LEFT VIEWS Optional 45EVT10-10" Round Transition Kit Shown 5 1/4" FRONT VIEW (Doors removed) RIGHT VIEWS Optional Transitions (45EVT10) shown Optional 45EVDF Rectangular 1" X 8" Flange Kit Shown 13

16 HE1XINH Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: CFM AHRI 10 Certified Core: One L15-00 Airflow Rating Points (for AHRI): 750 CFM and 5 CFM Number Motors: Two V HZ Phase FLA Min. Cir. Amps Max. Fuse Size 1 Single Single Single G5 Performance Effectiveness (%) CFM , Sensible Winter Total Summer Total Control Voltage: 4 VAC Filters: Two total, MERV 8, pleated, 0 x 0 nominal size Weight: 11 lbs (unit), 50 lbs (shipping weight) Shipping Dimensions: 44 W x 56 L x 7 H *At AHRI 10 standard conditions (See certified data on page 67 for core components.) Airflow Performance Motor HP Phase External Static Pressure (Inches Water Column) (Two DD) Single Phase 970 CFM 1,490 Watts 95 CFM 1,375 Watts 8 CFM 1,70 Watts 795 CFM 1,1 Watts 70 CFM 1,030 Watts 635 CFM 950 Watts 350 CFM 750 Watts 0.75 (Two DD) Phase 1,030 CFM 1,0 Watts 1,010 CFM 1,10 Watts 975 CFM 1,1 Watts 880 CFM 1,050 Watts 800 CFM 990 Watts 700 CFM 850 Watts 530 CFM 70 Watts 14 (800) Fax: (8) 1-84

17 HE1XINH Unit Dimensions : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside Alternate Power Wiring Inlet 7/8" Dia. 54 3/4" Overall Alternate Control Wiring Inlet 7/8" Dia. 0 5/8" 50 1/8" Maximum Door Extension 40 5/8" Minimum Service Area (Doors can be taken off hinges.) 1 7/8" 8 5/8" Ø1" TYP Control Wiring Inlet 7/8" Dia. Power Wiring Inlet 7/ 8" Dia. 49 1/8" Case TOP VIEW 1 3/4" Overall 10 3/8" 8 3/8" 34 7/8" Case 8 1/4" 36 3/8" Overall 9 1/" 9 5/8" LEFT VIEW FRONT VIEW RIGHT VIEW

18 HE1XINV Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: CFM AHRI 10 Certified Core: One L15-00 Airflow Rating Points (for AHRI): 750 CFM and 5 CFM Number Motors: Two V HZ Phase FLA Min. Cir. Amps Max. Fuse Size 1 Single Single Single G5 Performance Effectiveness (%) CFM , Sensible Winter Total Summer Total Control Voltage: 4 VAC Filters: Two total, MERV 8, pleated, 0 x 0 nominal size Weight: 11 lbs (unit), 50 lbs (shipping weight) Shipping Dimensions: 44 W x 56 L x 7 H *At AHRI 10 standard conditions (See certified data on page 67 for core components.) Airflow Performance Motor HP Phase External Static Pressure (Inches Water Column) (Two DD) Single Phase 970 CFM 1,490 Watts 95 CFM 1,375 Watts 8 CFM 1,70 Watts 795 CFM 1,1 Watts 70 CFM 1,030 Watts 635 CFM 950 Watts 350 CFM 750 Watts 0.75 (Two DD) Phase 1,030 CFM 1,0 Watts 1,010 CFM 1,10 Watts 975 CFM 1,1 Watts 880 CFM 1,050 Watts 800 CFM 990 Watts 700 CFM 850 Watts 530 CFM 70 Watts 16 (800) Fax: (8) 1-84

19 HE1XINV Unit Dimensions Power Wiring Inlet 7/8" Dia. Control Wiring Inlet 7/8" Dia. LEFT VIEW 40 3/8" Overall FRONT VIEW 1 3/4" Overall 10 3/8" RIGHT VIEW 17" 41 5/8" 0 5/8" 17" 41 1/" 50 5/8" 51 3/8" Overall 1 7/8" 10 3/8" 34 7/8" Case 49 1/8" Case TOP VIEW 40 5/8" Minimum Service Area (Doors can be taken off hinges.) 50 1/8" Maximum Door Extension : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside Ø1" TYP 17

20 HEXINH Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 500-,000 CFM AHRI 10 Certified Core: Two L15-00 Airflow Rating Points (for AHRI): 1,500 CFM and 1,10 CFM Number Motors: Direct Drive (DD) Four, Belt Drive (BD) Two G5 Performance Effectiveness (%) CFM 500 1,000 1,500,000 Sensible Winter Total Summer Total Drive HP DD 0.75 BD 1.5 BD Volts HZ Phase FLA Control Voltage: 4 VAC Single Single Single Single Single Min. Cir. Amps Max. Fuse Size Filters: Four total, MERV 8, pleated, 0 x 0 nominal size Weight: 414 lbs (unit), 40 lbs (shipping weight) Shipping Dimensions: 50 W x 6 L x 41 H *At AHRI 10 standard conditions (See certified data on page 67 for core components.) Airflow Performance Motor HP 0.75 (Four DD) Single Phase 0.75 (Four DD) Phase 1.5 (BD) (BD) Blower RPM Nominal N/A N/A N/A N/A 1,000 1,30 1,40 1,0 1,470 1,6 Turns Open N/A N/A N/A N/A External Static Pressure (Inches Water Column) ,950 CFM,40 Watts 1,9 CFM,500 Watts 1,830 CFM,5 Watts 1,840 CFM,300 Watts 1,670 CFM,00 Watts 1,700 CFM,15 Watts 1,400 CFM 1,795 Watts 1,0 CFM 1,900 Watts 1,0 CFM 1,490 Watts 1,380 CFM 1,700 Watts 700 CFM 1,190 Watts 1,190 CFM 1,500 Watts 800 CFM 1, Watts CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 1, , , , , Note: Brake Horse Power (BHP) is for one blower motor package only. 1, , , , , , , , , , , , , , 1.3 1, , , , , , , , , , (800) Fax: (8) 1-84

21 HEXINH Unit Dimensions 54 7/8" overall 59" Service Area TOP VIEW 41 1/4" 49 1/4" case 4" TYP 8" 34 3/4" 3/8" 33" 7/8" 35 1/4" Case 1 5/8" 36 5/8" 14" typ " Service Area LEFT VIEW Belt Driven Version LEFT VIEW Direct Drive Version Filters FRONT VIEW RIGHT VIEW 3 1/" 0 5/8" 3/4" 19 5/8" Wiring Entry 7/8" Dia. E-Box E-Box : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside Note: Door lifts away. Note: All duct flanges are 14" x 4". 19

22 HEXINV Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 500-,000 CFM AHRI 10 Certified Core: Two L15-00 Airflow Rating Points (for AHRI): 1,500 CFM and 1,10 CFM Number Motors: Direct Drive (DD) Four, Belt Drive (BD) Two G5 Performance Effectiveness (%) CFM 500 1,000 1,500, Sensible Winter Total Summer Total Drive HP DD 0.75 BD 1.5 BD Volts HZ Phase FLA Control Voltage: 4 VAC Single Single Single Single Single Min. Cir. Amps Max. Fuse Size Filters: Four total, MERV 8, pleated, 0 x 0 nominal size Weight: 399 lbs (unit), 40 lbs (shipping weight) Shipping Dimensions: 48 W x 6 L x 55 H *At AHRI 10 standard conditions (See certified data on page 67 for core components.) Airflow Performance Motor HP 0.75 (Four DD) Single Phase 0.75 (Four DD) Phase 1.5 (BD) (BD) Blower RPM Nominal N/A N/A N/A N/A 1,000 1,30 1,40 1,0 1,470 1,6 Turns Open N/A N/A N/A N/A External Static Pressure (Inches Water Column) ,870 CFM,1 Watts 1,870 CFM,500 Watts 1,70 CFM,070 Watts 1,70 CFM,300 Watts 1,50 CFM 1,900 Watts 1,540 CFM,15 Watts 1,90 CFM 1,7 Watts 1,350 CFM 1,950 Watts 1,080 CFM 1,505 Watts 1,40 CFM 1,730 Watts 700 CFM 1,10 Watts 1,030 CFM 1,490 Watts 800 CFM 1,40 Watts CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 1, , , , , Note: Brake Horse Power (BHP) is for one blower motor package only. 1, , , , , , , , , , , , , , 1.3 1, , , , , , , , , , (800) Fax: (8) 1-84

23 HEXINV Unit Dimensions 19 3/8" LEFT END VIEW BELT DRIVE 6 3/8" E-box power wire 7/8" Dia. 5 7/8" LEFT END VIEW DIRECT DRIVE 39 1/4" 34 1/8" 74 7/8" Clear 4 1/4" 43 3/4" TOP VIEW and Service Area 19 3/8" 35 1/4" w/ screws 38 3/4" FRONT VIEW Note: All duct flanges are 14" x 4". 49 1/8" : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside RIGHT END VIEW BELT DRIVE 41 1/" 4" 8 1/8" 50 5/8" 14" 35 5/8" 3 1/" RIGHT END VIEW DIRECT DRIVE 1

24 HE3XINH Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 750-3,300 CFM AHRI 10 Certified Core: L15-00 Airflow Rating Points (for AHRI):,50 CFM and 1,690 CFM Number Motors: Two G5 Performance Effectiveness (%) CFM 1,500,000,500 3, Sensible Winter Total Summer Total HP Volts HZ Phase FLA Control Voltage: 4 VAC Single Single Min. Cir. Amps Filters: Six total, MERV 8, pleated, 0 x 0 nominal size Weight: 675 lbs (unit), 700 lbs (shipping weight) Shipping Dimensions: 7 W x 84 L x 46 H Max. Fuse Size *At AHRI 10 standard conditions (See certified data on page 67 for core components.) Airflow Performance Motor HP 3 5 Blower RPM Nominal 1,095 1,0 1,340 1,345 1,535 1,685 1,495 1,675 1,855 Turns Open External Static Pressure (Inches Water Column) CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP, , , ,40.3,850.8, , ,7 1.3, , ,80.,7.7, , , , , ,090.1, , , , , ,7.0,380.5,6.9,80.8, , , ,80 1.9,090.4,470.7,040.7, , ,810.,80.6 1,60.5, , ,330.1, ,140.4,090.7,7 4.0 (800) Fax: (8) 1-84

25 5 1/8" 6 1/8" 40 3/8" HE3XINh Unit Dimensions 6 1/4" Left View 64 1/" overall Top View 57 1/4" Front View 6 1/4" Right View 3/8" 5 1/" 40 3/8" 1" 18 5/8" 6 1/4" 97" Service Area E-box 1" 39" E-box 55 1/8" Control Wiring Inlet 58 1/8" Power Wiring Inlet Note: There are two 1" x 1" discharges. 64 1/" Service Area : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside 1" X 34" 4 1/4" 1" X 34" 3

26 HE3XINV Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 750-3,300 CFM AHRI 10 Certified Core: L15-00 Airflow Rating Points (for AHRI):,50 CFM and 1,690 CFM Number Motors: Two G5 Performance Effectiveness (%) CFM 1,500,000,500 3, Sensible Winter Total Summer Total HP Volts HZ Phase FLA Control Voltage: 4 VAC Single Single Min. Cir. Amps Filters: Six total, MERV 8, pleated, 0 x 0 nominal size Weight: 640 lbs (unit), 675 lbs (shipping weight) Shipping Dimensions: 45 W x 70 L x 70 H Max. Fuse Size *At AHRI 10 standard conditions (See certified data on page 67 for core components.) Airflow Performance Motor HP 3 5 Blower RPM Nominal 1,095 1,0 1,340 1,345 1,535 1,685 1,495 1,675 1,855 Turns Open External Static Pressure (Inches Water Column) CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 1, ,00 1.5, ,400.,70.7, , ,0 1. 1,9 1.4,1 1.6,50.,450.5, , , , , , , ,970.1,50.4, , , , , , ,950.3,540.8,090.4, , , , ,650., ,710.,380.9, ,00.0, ,330.1,090.7, , ,810.5, (800) Fax: (8) 1-84

27 HE3XINV Unit Dimensions 95 7/8" Service Area : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside 61 3/4" 58 1/8" 61 3/4" 55 7/8" 1" 35 1/4" 1" E-box 8 3/4" 3 7/8" 6" 47" 1" 37 1/" 1" 47" 6" 39 3/8" overall 43 1/4" Service Area 61 3/4" Unit Top View 14" X 8" 14" X 8" 7/8" Dia. Wiring Entries 8 3/4" 1" x 1" 1" 38 7/8" 38 7/8" 1" 1" x 1" Left View Front View Right View 5

28 HE4XINH Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 1,000-4,400 CFM AHRI 10 Certified Core: Four L15-00 Airflow Rating Points (for AHRI): 3,000 CFM and,50 CFM Number Motors: Two G5 Performance Effectiveness (%) CFM 1,000,000 3,000 4, Sensible Winter Total Summer Total HP Volts HZ Phase FLA Control Voltage: 4 VAC Single Sinlge Min. Cir. Amps Max. Fuse Size Filters: Eight total, MERV 8, pleated, 0 x 0 nominal size Weight: 846 lbs (unit), 900 lbs (shipping weight) Shipping Dimensions: 84 W x 9 L x 46 H *At AHRI 10 standard conditions (See certified data on page 67 for core components.) Airflow Performance Motor HP 3 5 Blower RPM Nominal 1,010 1,10 1,370 1,345 1,535 1,685 1,495 1,675 1,855 Turns Open External Static Pressure (Inches Water Column) CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP, , ,95.1 3,83.9 3, ,3 3.8,00 0.9, , ,68.9 3, , ,7 0.8, , , , , , , ,0.0, , , , , ,540 1., 1.9, , , ,686. 3, , , , , ,003.8,301.1, , , , ,878.0, ,7 1.9, , (800) Fax: (8) 1-84

29 HE4XINh Unit Dimensions 64 1/" overall : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside 8" 5 1/8" 5 1/" 74 7/8" Control Wiring Inlet 77 7/8" Power Wiring Inlet 1" X 40" 3/8" Left View Front View Right View 5 1/" 40 3/8" 18 5/8" 116 3/4" Service Area E-box E-box 1" X 40" 40 3/8" 8" 39" 1" x 3" typ 64 1/" Service Area Top View 57 1/4" 8" 4 1/4" 7

30 HE4XINV Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 1,000-4,400 CFM AHRI 10 Certified Core: Four L15-00 Airflow Rating Points (for AHRI): 3,000 CFM and,50 CFM Number Motors: Two G5 Performance Effectiveness (%) CFM 1,000,000 3,000 4, Sensible Winter Total Summer Total HP Volts HZ Phase FLA Control Voltage: 4 VAC Single Sinlge Min. Cir. Amps Max. Fuse Size Filters: Eight total, MERV 8, pleated, 0 x 0 nominal size Weight: 8 lbs (unit), 875 lbs (shipping weight) Shipping Dimensions: 45 W x 90 L x 70 H *At AHRI 10 standard conditions (See certified data on page 67 for core components.) Airflow Performance Motor HP 3 5 Blower RPM Nominal 1,010 1,10 1,370 1,345 1,535 1,685 1,495 1,675 1,855 Turns Open External Static Pressure (Inches Water Column) CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP, , ,068. 3,04.0 3,45.7 3, , , , ,754.0, ,6.6 3, , , , , , ,955.5,80.4 3, , , , , , ,148.9, , , , , , ,4.,884.8,68., , , ,11 1.5,093.0, ,917.1, , ,7 1.9,69.4 1,53 1.9,39.8 3, (800) Fax: (8) 1-84

31 HE4XINV Unit Dimensions : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside 1 1/" Service Area 81 3/8" 35 1/4" 81 3/8" 75 1/" 38 3/4" 1" 3 7/8" 6" 8 1/" 47" 6 1/4" 39 3/8" with flanges 81 1/" Unit Top View 7/8" Dia. Wiring Entries 14" X 34" 38 7/8" 1" 14" X 34" E-box 8 1/" 47" 37 1/" 1" X 3" 1" X 3" Left View Front View Right View 9

32 HE6XIN Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 1,500-6,500 CFM AHRI 10 Certified Core: Six L15-00 Airflow Rating Points (for AHRI): 4,500 CFM and 3,375 CFM Number Motors: Two G5 Performance Effectiveness (%) CFM 3,000 4,000 5,000 6, Sensible Winter Total Summer Total HP Volts HZ Phase FLA Control Voltage: 4 VAC Min. Cir. Amps Max. Fuse Size Filters: Twelve total, MERV 8, pleated, 0 x 0 nominal size Weight:,340 lbs (unit),,640 lbs (shipping weight) Shipping Dimensions: 85 W x 114 L x 85 H *At AHRI 10 standard conditions (See certified data on page 67 for core components.) Airflow Performance Motor HP Blower RPM Nominal 1,4 1,610 1,75 1,5 1,740 1,865 Turns Open External Static Pressure (Inches Water Column) CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 5, , , , , , , , , , , , , , , , , , , , , ,00.9 4, , , , , , , , , , , , , , , , , (800) Fax: (8) 1-84

33 HE6XIN Unit Dimensions 108 1/" Base 148 1/4" Service Area 11 3/4" Unit Roof 6" 18" 108 1/" Base LEFT VIEW 39 1/" Min. Clearance 85 1/" Unit Roof FRONT VIEW 1 1/" Service Area 34" Service Area 4" 9" 4" 77" Power and Control Wiring Entries 7/8" Dia. 6" RIGHT VIEW INDOOR UNITS: BLOWER Outlet is 18" x 4". 4" x 36" Duct Flange is also supplied. Field install only in location shown. 4" typ Core Access " 36" 9 1/" 49" BACK VIEW TOP VIEW : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside Power and Control Wiring Entries Front Views at 0.5X: BLOWER ROTATION BLOWER Outlet is 18" x 4". 4" x 36" Duct Flange is also supplied. Field install only in location shown. 78 1/4" Overall 55" 36" 31

34 HE8XIN Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range:,000-8,000 CFM AHRI 10 Certified Core: Eight L15-00 Airflow Rating Points (for AHRI): 6,000 CFM and 4,500 CFM Number Motors: Two G5 Performance Effectiveness (%) CFM,000 4,000 6,000 8, Sensible Winter Total Summer Total HP Volts HZ Phase FLA Control Voltage: 4 VAC Min. Cir. Amps Max. Fuse Size Filters: Sixteen total, MERV 8, pleated, 0 x 0 nominal size Weight:,55 lbs (unit),,85 lbs (shipping weight) Shipping Dimensions: 85 W x 114 L x 85 H *At AHRI 10 standard conditions (See certified data on page 67 for core components.) Airflow Performance Motor HP Blower RPM Nominal 1,4 1,610 1,75 1,5 1,740 1,865 1,810,00,105 Turns Open External Static Pressure (Inches Water Column) CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 5, 3. 6, , , , , , , , , , , 5.3 6, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,70.9 5, , , , , , , , (800) Fax: (8) 1-84

35 HE8XIN Unit Dimensions 108 1/" Base 148 1/4" Service Area 11 3/4" Unit Roof 6" 18" 108 1/" Base LEFT VIEW 39 1/" Min. Clearance 85 1/" Unit Roof FRONT VIEW 1 1/" Service Area 34" Service Area 4" 9" 4" 77" Power and Control Wiring Entries 7/8" Dia. 6" RIGHT VIEW INDOOR UNITS: BLOWER Outlet is 18" x 4". 4" x 36" Duct Flange is also supplied. Field install only in location shown. 4" typ Core Access " 36" 9 1/" 49" BACK VIEW TOP VIEW : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside Power and Control Wiring Entries Front Views at 0.5X: BLOWER ROTATION BLOWER Outlet is 18" x 4". 4" x 36" Duct Flange is also supplied. Field install only in location shown. 78 1/4" Overall 55" 36" 33

36 Commercial OutDOOR Products Many airflow orientation options. Weatherized cabinets with hoods for outdoor applications. Wide range of airflow and static capacities. Easy installation and service. AHRI certified performance data for efficiency and cross leakage. UL tested flammability and smoke generation that meets NFPA 90A and 90B test standards for commercial applications. Ten year core warranty. RenewAire means Trouble-Free ERV. : Exhaust Air to outdoors : Outdoor Air intake : Room Air to be exhausted : Fresh Air to inside Contact RenewAire for other application schematics. 34 (800) Fax: (8) 1-84

37 Packaged Rooftop Energy Recovery Ventilators: EV450RT, HE1XRT, HEXRT, HE3XRT, HE4XRT, HE6XRT & HE8XRT Part I - General A. Product Specification 1.Energy Recovery Ventilator (ERV) shall be a packaged unit as manufactured by RenewAire and shall transfer both heat and humidity using static plate core technology. B. Quality Assurance 1.The energy recovery cores used in these products shall be third party Certified by AHRI under its Standard 10 for Energy Recovery Ventilators. AHRI published certifications shall confirm manufacture s published performance for airflow, static pressure, temperature and total effectiveness, purge air (CF) and exhaust air leakage (TR). Products that are not currently AHRI Certified will not be accepted.. Manufacturer shall be able to provide evidence of independent testing of the core by Underwriters Laboratory (UL), verifying a maximum flame spread index (FSI) of 5 and a maximum smoke developed index (SDI) of 50 thereby meeting NFPA 90A and NFPA 90B requirements for materials in a compartment handling air intended for circulation through a duct system. The method of test shall be UL Standard Unit shall be Listed under UL 181 Standard for Ducted Air to Air Heat Exchangers (Note that a few low volume product or product configurations are not UL Listed). Units intended for Outdoor Use shall be listed using the specific UL requirements for rain penetration, corrosion protection and seal durability and shall be so labeled. 4. The ERV core shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of ten years from the date of purchase. The balance-of-unit shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of two years from the date of purchase. Part II Performance A. Energy Transfer The ERV shall be capable of transferring both sensible and latent energy between airstreams. Latent energy transfer shall be accomplished by direct water vapor transfer from one airstream to the other, without exposing transfer media in succeeding cycles directly to the exhaust air and then to the fresh air. B. Passive Frost Control The ERV core shall perform without condensing or frosting under normal operating conditions (defined as outside temperatures above -10 F and inside relative humidity below 40%). Occasional more extreme conditions shall not affect the usual function, performance or durability of the core. No condensate drains will be allowed. C. Continuous Ventilation Unit shall have the capacity to operate continuously without the need for bypass, recirculation, pre-heaters or defrost cycles under normal operating conditions. D. Positive Airstream Separation Water vapor transfer shall be through molecular transport by hydroscopic resin and shall not be accomplished by porous plate mechanisms. Exhaust and fresh airstreams shall travel at all times in separate passages, and airstreams shall not mix. E. Laminar Flow Airflow through the ERV core shall be laminar over the products entire operating airflow range, avoiding deposition of particulates on the interior of the energy exchange plate material. Part III Product A. Construction. No condensate drain pans or drains shall be allowed and unit shall be capable of operating in both winter and summer conditions without generating condensate. 3. The unit case shall be constructed of G90 galvanized, 0-gauge steel, with lapped corners and zinc plated screw fasteners. The unit roof shall be one piece or have watertight standing seam joints and shall overlap wall panels and doors in order to positively shed water. 4. Access doors shall provide easy access to blowers, ERV cores and filters. Doors shall have an airtight compression seal using closed cell foam gaskets rated for outdoor exposure. 5. Weatherhoods shall be screened to exclude birds and animals. Inlet weatherhoods shall be sized to maintain inlet velocities below 500 fpm, and equipped with rain excluder baffles. 6. Case walls and doors shall be insulated with 1 inch, 4 pound density, foil/ scrim faced, high-density fiberglass board insulation, providing a cleanable surface and eliminating the possibility of exposing the fresh air to glass fibers. 7. The ERV cores shall be protected by a MERV-8 rated, nominal, pleated, disposable filter in both airstreams. 8. Unit shall have single-point power connection and a single-point 4 VAC contactor control connection (Except Inverter Ready units that have terminal connections for an independent inverter for each airstream). 9. Blower motors shall be EPACT compliant for energy efficiency and be thermally protected or supplied with external starters. 10. Blowers shall be quiet running, forward curve type and be either direct drive or belt drive. HE6X and HE8X units use backward incline, belt drive blower packages. Belt drive motors shall be provided with adjustable pulleys and motor mounts allowing for proper belt tensioning. B. Options (Select options based on application requirements) 1. Provide unit and duct connection orientation per project schedule.. Provide double wall construction with 4-gauge galvanized steel liner. 3. Units are available single or three phase at a full range of operating voltages. See project schedule. 4. Provide motor horsepower as specified in project schedule. 5. Provide inverter-ready units which include shielded power wiring and terminal connections for inverters (inverters provided and installed by others). 6. Provide factory installed fused disconnects. 7. Provide factory installed non-fused disconnects. 8. Provide factory installed transformer/relay package to supply a 4VAC power source. 9. Provide factory installed filter monitors for each airstream. 10. Provide 14 inch high, non-pitched roof curbs as available from the factory. Pitched curbs, vibration curbs, seismic curbs and other custom curbs are available directly from curb manufacturer. 11. RTC (RoofTop Connect) units shall have return air and fresh air ducts configured to permit direct tie-in to rooftop air handlers using factory offered transition piece. (See separate specification for factory transition availability.) 1. Provide high wind tie-down kit. 1. The energy recovery component shall be of fixed-plate cross-flow construction, with no moving parts. 35

CE6500 Energy Recovery Ventilator

CE6500 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge

More information

Operation and Installation Manual. Max Series

Operation and Installation Manual. Max Series Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat

More information

Innovent LASER Packaged Fresh Air Conditioning Units

Innovent LASER Packaged Fresh Air Conditioning Units LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent

More information

Mechanical Rooftop Custom Capabilities

Mechanical Rooftop Custom Capabilities Mechanical Rooftop Custom Capabilities Mechanical Construction Capabilities Price manufactures a wide range of custom gas heat and DX cooled units to meet your new construction and retrofit needs. In addition

More information

Dehumidification Frequently Asked Questions

Dehumidification Frequently Asked Questions Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Bring the fresh in. Dedicated Outside Air Systems

Bring the fresh in. Dedicated Outside Air Systems Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health

More information

Low Cost. Lower Energy Costs. Higher Efficiency.

Low Cost. Lower Energy Costs. Higher Efficiency. HI-E DRY dehumidifiers remove two to three times more water per kilowatt hour of electricity than conventional dehumidifiers. Low Cost. Lower Energy Costs. Higher Efficiency. Therma-Stor designed an efficient,

More information

Johnson Air-Rotation Systems

Johnson Air-Rotation Systems AR Series TM Johnson Air-Rotation Systems Solution TM D Series TM FF Series TM 80/20 PR Series TM Johnson Air-Rotation systems announces a major addition to its product line, completing its line of high

More information

ROOF TOP MOUNTED Air Handler Specification

ROOF TOP MOUNTED Air Handler Specification ROOF TOP MOUNTED Air Handler Specification PART 1: GENERAL (Model RT) Mechanical Specification 1.01 WORK INCLUDED A. Provide complete air handling unit(s) suitable for outdoor installation. Contractor

More information

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water 2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change

More information

F9MXE. Product Specifications

F9MXE. Product Specifications 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Select models earn the ENERGY STAR (See below, indicated with check mark.) Xtra SEER ECM blower motor Supports

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx

More information

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION 238221 - BLOWER COIL UNITS

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION 238221 - BLOWER COIL UNITS ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

Answers to Your Questions from the Webinar

Answers to Your Questions from the Webinar 2008 Desert Aire and USA Swimming. Used by permission. Desert Aire & USA Swimming - Aquatics Webinar - Answers to Your Questions Answers to Your Questions from the Webinar Thank you for your interest in

More information

Installation Manual CLIFC Fan & Coil Variable Speed

Installation Manual CLIFC Fan & Coil Variable Speed Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation

More information

Basics of HVAC Cleaning

Basics of HVAC Cleaning Basics of HVAC Cleaning Seminar Outline Residential 1. Types of systems used and why 2. Types of air distribution systems 3. System components 4. Determining the need for cleaning (ACR2002) 5. Project

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION

More information

A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses

A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses Robert L Crosby Jr, Biorealis Systems, Inc. Abstract: Bristol Bay Housing Authority (BBHA) currently

More information

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Four-Way Fan Exhaust Supply Mix Recirculate BUILDING VALUE IN AIR. October 2005 Recirculating Roof Fans Exhaust/Supply/Recirculation/Mix Model ESRMD

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

Pool Dehumidification Basics

Pool Dehumidification Basics Copyright 2009 Wescor. All rights reserved. Permission granted to reproduce for personal and educational use only. When energy costs were low, many pool owners considered only first cost when choosing

More information

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled

More information

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SINGLE PACKAGE VERTICAL AIR CONDITIONERS SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,

More information

SECTION 23 34 13. A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

SECTION 23 34 13. A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer. PART 1 GENERAL SECTION 23 34 13 HVAC FANS 1.01 SUMMARY A. Section Includes: 1. Exhaust fans. 2. Transfer fans. B. Related Documents: 1. Drawings and general provisions of the Contract, including General

More information

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac II air conditioner is a vertical, wall mounted, cost effective air conditioner

More information

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin 30-34 / March 2013

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin 30-34 / March 2013 Bulletin 30-34 / March 2013 INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES General The information on the following pages is to provide the installer the necessary information to properly install the

More information

Ventilation Solutions Radon Mitigation

Ventilation Solutions Radon Mitigation Ventilation Solutions Radon Mitigation 2 Radon Mitigation Radon is a health hazard with a simple solution Radon is everywhere! You can t see radon and you can t smell it or taste it, but it may be a problem

More information

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. QUALITY AIR STARTS HERE. AccuExchange Energy Recovery Ventilator Improve your home s indoor environment by exchanging stale

More information

Single Package Vertical Air Conditioners. Vert-I-Pak

Single Package Vertical Air Conditioners. Vert-I-Pak Single Package Vertical Air Conditioners Vert-I-Pak Installs easily in a closet for quiet operation and provides a more homelike appearance for your guests. THE EXPERTS IN ROOM AIR CONDITIONING A Better

More information

Quest 105, Dry155, and 205 Dual

Quest 105, Dry155, and 205 Dual Quest 105, Dry155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.

More information

Roof Curbs, Extensions and Equipment Supports

Roof Curbs, Extensions and Equipment Supports Roof s, Extensions and Equipment Supports December 2012 Roof Page s, Header Extensions and Equipment Supports Table of Contents Model GPI Standard and Optional Construction Features... 3 Model Number Code....

More information

G9MXE. Product Specifications

G9MXE. Product Specifications Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)

More information

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3

More information

HVAC Checklist - Long Form

HVAC Checklist - Long Form HVAC Checklist - Long Form Page 1 of 14 Appendix B discusses HVAC system components in relation to indoor air quality. utside Air Intake Location pen during occupied hours? Unobstructed? Standing water,

More information

CADB and CADT-D / DI / DC Series

CADB and CADT-D / DI / DC Series HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised

More information

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating

More information

SPACE COOLERS. P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com. The leader in packaged Space Cooling.

SPACE COOLERS. P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com. The leader in packaged Space Cooling. SPACE COOLERS P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com The leader in packaged Space Cooling. 2 Table of Contents Description Space Cooler from Coil Company. A

More information

SECTION 15732 AIR CONDITIONING UNIT

SECTION 15732 AIR CONDITIONING UNIT SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration

More information

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715, 4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

Why is my air conditioner dripping on my customers?

Why is my air conditioner dripping on my customers? De-Mystifying HVAC Why is my air conditioner dripping on my customers? By Ron Prager One of the most frequent emergency service requests is a call for an air conditioner leaking water into the store. These

More information

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS 1.5, 2, 2.5, 3, 3.5, 4, 5 & 6 Ton Industrial Grade Wall Mounted Air Conditioners & Heat Pumps Unit Application Bebco Model IX-WAC/HP Industrial Grade Air Conditioners & Heat Pumps are designed as a total

More information

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =

More information

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health Background Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health This document provides guidelines for the design and installation of Class

More information

Glossary of HVAC Terms

Glossary of HVAC Terms Glossary of HVAC Terms Heating, Ventilation and Air Conditioning (HVAC) is a major sub- discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other

More information

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-

More information

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical

More information

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler Installation Operation Maintenance The WMSLW/WMBLW series is designed for installation in a closet, utility

More information

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.

More information

Residential Ventilation

Residential Ventilation Product Guide Residential Ventilation Aprilaire sets a new direction in residential ventilation with whole-home solutions based on building requirements, geographic climate zones and effective applications.

More information

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE UPF/HORIZONTAL 2-, VARIABLE SPEED GAS-FIRED FURNACE XV80 MODELS TUD2B060A9V3VB, TUD2B080A9V3VB TUD2C080A9V4VB, TUD2C080B9V4VB TUD2B00A9V3VB, TUD2C00A9V5VB TUD2C00B9V5VB, TUD2DA9V5VB TUD2DB9V5VB, TUD2DA9V5VB

More information

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER Dehumidification The highly efficient Ultra-Aire 100V dehumidifier utilizes refrigeration to cool the incoming air stream

More information

Ventilation Solutions Kitchens. fantech

Ventilation Solutions Kitchens. fantech Ventilation Solutions Kitchens 2 Kitchens Today s kitchens have become much more than a place for cooking and food preparation. The kitchen is the heart of the home. It s the center of activity for the

More information

How To Install A Perfect 16 Id Series Filter System

How To Install A Perfect 16 Id Series Filter System IQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System Perfect 16 Installation Manual Product Data High-Performance Medical-Grade Residential/Commercial Air Filtration System Application The

More information

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY USER MANUAL RESIDENTIAL USE ONLY VB0175 HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY GUIDELINES SET BY NATURAL RESOURCES CANADA

More information

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

ENHANCED LABORATORY HVAC SYSTEM

ENHANCED LABORATORY HVAC SYSTEM ENHANCED LABORATORY HVAC SYSTEM INTRODUCTION Since the early 1980's the attention to more energy efficient laboratory designs has been on the rise due to the increase in energy cost and the emergence of

More information

Installation, operation and maintenance manual TX 35A

Installation, operation and maintenance manual TX 35A Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2

More information

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT 48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED

More information

Installation Instructions

Installation Instructions VentilAire IV Whole-House Fresh Air Supply System Installation Instructions 914228 Flat Roof Kit 914229 Sloped Roof Kit 5" x 11' Class I Insulated Flexible Duct Plastic Clamps (2) Metal Clamps (2) Ceiling

More information

Centrifugal Fans and Pumps are sized to meet the maximum

Centrifugal Fans and Pumps are sized to meet the maximum Fans and Pumps are sized to meet the maximum flow rate required by the system. System conditions frequently require reducing the flow rate. Throttling and bypass devices dampers and valves are installed

More information

FIRE DAMPER APPLICATION GUIDE

FIRE DAMPER APPLICATION GUIDE FIRE AND CEILING RADIATION DAMPERS FIRE DAMPER APPLICATION GUIDE Use this application guide to help determine what type of fire damper best suits the application. Below are listed the ten Metal-Fab fire

More information

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with

More information

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and

More information

air conditioners how to choose a cooling system

air conditioners how to choose a cooling system air conditioners how to choose a cooling system taking responsibility As an individual, your efficient use of energy brings benefits such as lower bills, improved comfort levels in your home and a reduced

More information

UPBLAST & HOODED PROPELLER ROOF VENTILATORS

UPBLAST & HOODED PROPELLER ROOF VENTILATORS The Industrial Choice. Model D53 / B53 Model HD53 / HB53 UPBLAST & HOODED ELLER ROOF VENTILATORS Direct Drive & Belt Driven Model D53 / B53 Upblast Exhaust Fans Model HD53 / HB53 Hooded Supply & Exhaust

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess

More information

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes Vincent Pedalino FSL Home Improvements Phoenix, AZ 1 HVAC Basics Ways to improve the performance of existing air conditioning

More information

Evaluate, Clean, and Tune Guidance

Evaluate, Clean, and Tune Guidance Evaluate, Clean, and Tune Guidance The Evaluate, Clean and Tune (ECT) process serves three essential purposes in the Weatherization Assistance Program (WAP). The first is to evaluate the existing system

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008 Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be

More information

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H HR SERIES HEAT RECOVERY VENTILATOR (HRV) Home Owners Guide Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR100V HR160H & HR220H READ AND SAVE THIS GUIDE PP0924 09/2013 ABOUT S&P S&P is the world's

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs. Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12

More information

Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011

Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011 Fans and Air Handling Units Will Rea and Paul Pilutti February 16 th, 2011 HTS Lunch and Learns Available Online Visit www.htseng.com Engineering Tools Resource Center Contents Fans Fan Curves Fan Laws

More information

Underwriters Laboratories Testing Information

Underwriters Laboratories Testing Information Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum

More information

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO. Upflow/ Horizontal Left, Downflow/ Horizontal Right Speed Two Stage Condensing Gas-Fired Furnace XV 95 TUH2B060A9V3VB TUH2B080A9V3VB TUH2B080A9V4VB TUH2C100A9V4VB TUH2C100A9V5VB TUH2D120A9V5VB Direct Vent

More information

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER The instructions that follow are to assist you in completing the information required when making a fan or blower selection. If you need additional

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

AIR-COOLED CONDENSERS Technical Guide

AIR-COOLED CONDENSERS Technical Guide BN-ACCTB0306 March, 2006 AIR-COOLED CONDENSERS Technical Guide Monarch and Ambassador Series TABLE OF CONTENTS Overview... 2, 3 Features & Options... 3, 4 Three Solutions...5 Nomenclature...6 Condenser

More information

How To Design A Building In New Delhi

How To Design A Building In New Delhi ENERGY EFFICIENT HVAC DESIGN FOR COMPOSITE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce energy consumption

More information

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce

More information

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget A PRIMER Educational HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget Contents: Introduction: The best HVAC system is durable, reliable

More information

Lesson 36 Selection Of Air Conditioning Systems

Lesson 36 Selection Of Air Conditioning Systems Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Snow Enclosure and Subbase Fuel Tank Package Applicable to the following: 80/100/150REOZJF 125REOZJG Enclosure with Standard Subbase Fuel Tank Enclosure with State

More information

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R

More information

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information