Modicon TSX Micro automation platform 1 TSX3705PLCs

Size: px
Start display at page:

Download "Modicon TSX Micro automation platform 1 TSX3705PLCs"

Transcription

1 Presentation, description, selection TSX705PLCs Presentation The TSX 7 05 PLC comprises a rack which integrates a 00/40 V power supply, a processor including a Kword memory (program, data and constants), Flash EPROM backup memory, a TSX DMZ 8DR discrete I/O module (6 inputs and relay outputs) and an available slot. The available slot can accept: b standard format discrete I/O module of any type. b half format discrete I/O, safety, analog I/O or counter modules. Description The TSX 7 05 PLC comprises: -slot rack. Centralized display block. Terminal port (TER) (Uni-Telway master/slave, Modbus RTU slave protocol or characters string). 4 Cover for accessing the power supply terminals. 5 Discrete module with 6 inputs and outputs, placed in the first slot (positions and ). Including screw terminal block. 6 Cover for accessing optional battery Available slot. 8 Reset button. Selection Selection of modules to be inserted in addition to the 6-input/-output module present at rack no. Type of module to be inserted Max number of modules Format Connection Standard Half Connector Term.blk Discrete Inputs/Outputs 8 inputs inputs inputs 4outputs 8outputs outputs 6 inputs/outputs 8 inputs/outputs 64 inputs/outputs Preventa safety module Analogue I/O 4 or 8 inputs or 4 outputs 4 inputs and outputs Counter/positioning channels incremental code channel incremental code channels absolute encoder channel Possible insertion 4050-EN_Ver6.0.fm/

2 Presentation, description, selection (continued) TSX 7 08 PLCs Presentation The TSX 7 08 PLC comprises a rack which integrates a 00/40 V power supply, a processor including a Kword memory (program, data and constants), Flash EPROM backup memory, TSX DMZ 8DR discrete I/O modules (6 inputs and relay outputs) and an available slot. The available slot can accept: b standard format discrete I/O module of any type. b half format discrete I/O, safety, analog I/O or counter modules. Description The TSX 7 08 PLC comprises: -slot rack. Centralized display block. Terminal port (TER) (Uni-Telway master/slave, Modbus RTU slave protocol or characters string). 4 Cover for accessing the power supply terminals. 5 Two discrete modules with 6 inputs and outputs, placed in the first and second slot (positions to 4). Including screw terminal block. 6 Cover for accessing optional battery Available slot. 8 Reset button. Selection Selection of modules to be inserted in addition to the 6-input/-output module present at rack no. Type of module to be inserted Max number of modules Format Connection Standard Half Connector Term.blk Discrete Inputs/Outputs 8 inputs inputs inputs 4 outputs 8 outputs outputs 6 inputs/outputs 8 inputs/outputs 64 inputs/outputs Preventa safety module Analog I/O 4or8inputs or 4 outputs 4 inputs and outputs Counter/positioning channels incremental code channel incremental code channels absolute encoder channel Possible insertion 4050-EN_Ver6.0.fm/

3 Presentation, description, selection (continued) TSX70PLCs Presentation Description Compact and modular TSX 7 0 PLCs differ in their supply voltage and the type of discrete I/O module fitted in the first slot. Each TSX 7 0 configuration comprises a rack which integrates a power supply (c 4 V or a 00/40 V), a processor including a 4 Kword RAM memory (program, data and constants), a Flash EPROM backup memory, a real-time clock, a discrete I/O module (8 or 64 I/O) and an available slot. A TSX RKZ 0 mini extension rack enables the number of slots to be increased by (4 positions). Each available slot can accept: b standard format discrete I/O module of any type. b half format discrete I/O, safety, analog I/O or counter modules. Also, TSX 7 0 PLCs can connect to the Ethernet network TCP/IP or to a Modem via the TSX ETZ 40/50 external stand-alone module. 7 8 TSX 7 0 PLCs and the TSX RKZ 0 mini extension rack comprise: -slot base rack. Centralized display block. Terminal port (TER) (Uni-Telway, Modbus RTU master/slave protocol or characters string). 4 Cover for accessing the power supply terminals. 5 8 or 64 discrete I/O module, placed in the first slot (positions and ). 6 Cover for accessing optional battery. 7 Mini extension rack with available slots -(positions 5 to 8). 8 LED showing presence of c 4 V. 9 Power supply terminals protected by removable cover, to connect an auxiliary c 4 V power supply if PLCs are supplied with a 00/40 V Earth terminal. Connectors to the base PLC. Reset button. Selection TSX 7 0 base PLC selection Power supply I/O module integrated in st slot Connection Reference Number of inputs Number of outputs HE 0 Screw terminal c 4 V a 0/0 V Solid state c Relay Connector block 4 V c 4 V 6 TSX708DT 6 TSX 7 0 8DTK 6 TSX 7 0 8DR TSX DTK a 0/40V 6 TSX AR 6 TSX DR Selection of modules to be inserted ( slots available, that is a maximum of 6 positions) Type of module to be inserted Maximum number of modules () Format Connection 4 6 Stand. Half Connect. Term.blk Discrete Inputs/Outputs 8 inputs inputs inputs () 4outputs 8outputs outputs () 6 inputs/outputs 8 inputs/outputs () 64 inputs/outputs () Preventa safety module AS-Interface bus or I/O extension () Analog I/O 4or8inputs Counter/positioning channels Communication or4outputs or incremental encoder channels absolute encoder channel Ethernet TCP/IP or external Modem Possible selection or insertion External module () With TSX RKZ 0 mini extension rack. () This includes a standard format module to be inserted in the st slot of the PLC. () The remote discrete I/O extension modules and AS-Interface bus modules are installed in position 4 which means that their use is mutually exclusive EN_Ver6.0.fm/4

4 Presentation, description, selection (continued) TSX 7 / PLCs Presentation Description Modular TSX 7 / PLCs differ in their supply voltage and/or the possibility of fast counting and analogue functions integrated on the base. Each PLC comprises: a -slot rack which integrates a power supply (c 4 V or a 00/40 V), a processor including a 0 Kword RAM memory (program, data and constants), Flash EPROM backup memory, slots for a PCMCIA card ( communication card and memory extension card of 8 Kwords maximum) and a real-time clock. A TSX RKZ 0 mini extension rack enables the number of slots to be increased by (4 positions). Each available slot can accept: b standard format discrete I/O module. b half format discrete I/O, safety, analog I/O or counter modules. Also, TSX 7 / PLCs can connect to the Ethernet network TCP/IP or to a modem via the TSX ETZ 40/50 external stand-alone module TSX 7 / PLCs and the TSX RKZ 0 mini extension rack comprise: -slot base rack (positions to 6). Slot reserved for a standard format module. Centralized display block. 4 Terminal port (TER) (Uni-Telway, Modbus RTU master/slave protocol or characters string). 5 Man-machine interface port labeled AUX. 6 Cover for accessing the power supply terminals. 7 Slot for a PCMCIA memory extension card. 8 Slot for a PCMCIA communication card. 9 On TSX 7, SUB-D connectors type for integrated analogue and counter functions. 0 Mini extension rack with available slots (positions 7 to 0). 4 LED showing voltage presence of c 4 V Power supply terminals protected by removable cover, to connect an auxiliary c 4 V power supply if PLCs are supplied with a 00/40 V. Earth terminal. 4 Connectors to the base PLC. 5 Reset button. Selection Selection of modules to be inserted (5 slots available, that is a maximum of 9 positions) Type of module to be inserted Maximum number of modules () Format Connection Discrete Inputs/ Outputs 8 inputs () inputs () inputs () 4outputs () 8outputs () outputs () 6 inputs/outputs () 8 inputs/outputs () 64 inputs/outputs () Preventa safety module AS-Interface bus or I/O extension () Analog I/O 4 or 8 inputs or4outputs (4) inputs and 4 outputs (4) Stand. Half Connect. Term.blk Counting/ positioning or incremental encoder channels absolute encoder channel Communication (PCMCIA card on processor) Serial link CANopen bus Modbus bus Fipio Agent bus Uni-Telway bus Modbus Plus network Fipway network Communication Ethernet TCP/IP or external Modem External module Possible insertion () With TSX RKZ 0 mini extension rack. () Comprises a standard format module to be placed in st slot of the PLC. () The remote discrete I/O extension modules and AS-interface bus modules are installed in position 4 which means that their use is mutually exclusive. (4) With a maximum of (TSX AMZ 600/ASZ 00) modules in the base EN_Ver6.0.fm/5

5 Functions Functions Discrete inputs/outputs The range of in-rack discrete I/O modules offers several possibilities for meeting requirements: b Cost-effective connection where a c 4 V solution is required (mixed I/O modules with HE type 0 connectors for direct connection to pre-actuators in the device using cables with flying leads or direct connection to the TELEFAST pre-wired system). b Connection to the screw terminal block on the front panel of mixed I/O modules. A set of half format modules enable the PLC configuration to be adapted as closely as possible to the user's requirements in terms of number, range of I/O and type of connection. For further details, see pages 405/ to 405/. The TSX DPZ 0DA Preventa type safety relay module provides a monitoring function for the emergency stop pushbuttons or limit switches, and is adapted to conform to the safety requirements stipulated in EN For further details, see pages 408/ to 407/5. Remote discrete I/O extension module TSX 7 0// Micro PLCS offer two different possibilities for extending the I/O: b Either with the TSX STZ 0 remote discrete I/O extension module. The discrete I/ O of 4 Nano PLCs can be used at a distance of up to 00m (one of which can be a Nano extension PLC). These Nano PLCs can be used as remote discrete I/O or local slave PLCs. For further details, see pages 4056/ et 4056/. b The AS-Interface sensor/actuator bus. TSX Micro PLCs are connected to the AS-Interface bus via an AS-Interface master module. In this case, the PLC becomes the master station on the bus and manages a maximum of 48 I/O over a distance of up to 00 m (00 m with a repeater). For further details, see pages 478/ to 46/. b The CANopen machine bus. The communication of the Micro TSX 7 / PLCs enables the connectivity to the CANopen machine bus. It is appeared as a PCMCIA card equipped with a cable (length 0.5m) and a tap junction (with 9-way SUB-D connector). This TSX CPP 0 kit allows the direct linking to the bus and ensures the role of the master on the CANopen bus. The PCMCIA card is inserted into the reserved slot for communication card, available on the TSX 7 and TSX 7. For further details, see pages 465/ to 465/5. Analogue I/O and process control TSX Micro PLCs offer several ways of performing analogue processing: b For data input or commands which do not need a high resolution level, using I/O integrated in TSX 7 PLCs. b For precise measurement and commands, using TSX AEZ/ASZ/AMZ ppp half format analogue I/O modules. b To locate analog I/O remotely via the TSX STZ 0 rackmaster module with TSX 7 0// PLCs. The latter enables the use of three TSX AMN 400p analog extensions, each equipped with analogue inputs and one analog output. For further details, see pages 405/ and 405/4. TSX Micro PLCs have, as standard, process control functions which can be accessed by the user via the PL7 Micro, PL7 Junior or PL7 Pro programming software. For further details, see pages 45/ to 45/5. Description: pages 4050/ to 4050/ EN_Ver6.0.fm/6

6 Functions (continued) Counting/positioning Counter modules TSX Micro PLCs offer several ways of counting: b Using 500 Hz discrete inputs ( up/down counter channels with upcounting, downcounting or up/down counting functions, with or without detection of direction of operation). b 0 khz counter channels integrated into TSX 7 PLC bases ( 0 khz fast counter channels, with channel having down-counting functions as above). b Counting/positioning TSX CTZ modules pa, from khz or TSX CTZ B, from 00 khz... MHz. These half format modules are inserted in the available slots in the base rack. For further details, see pages 4054/ to 4/5. Communication TSX Micro PLCs offer several possibilities: b Integrated communication which offers cost-effective dialogue functions via the terminal port for TSX 7 05/08/0 PLCs or via the terminal and man-machine interface ports for TSX 7 / PLCs. These RS 485 type non-isolated links use Uni-Telway master/slave, Modbus RTU slave or character string. Also TSX 7 0// PLCs integrate Modbus master protocol. b PCMCIA format communication card for TSX 7 / PLCS. They have a dedicated slot for the PCMCIA format communication card ("Full-duplex" asynchronous serial link, CANopen bus, Fipio bus, Uni-Telway or Modbus, Modbus Plus or Fipway network). b Ethernet TCP/IP 0/00 MHz external modules. This external module connects to the terminal port of TSX 7 0// PLCs and has Uni-TE and Modbus messaging. It also allows connection to an external modem using PPP protocol. For further details, see pages 4/ to 4890/7. Fan modules TSX FAN ppp fan modules installed above TSX Micro PLCs ensure a forced air convection, which creates a uniform ambient temperature within the enclosure and eliminates any hot spots which might exist. Fan modules are required when the ambient temperature is between 60 C and 70 C. Forced ventilation is used to eliminate hot spots (). Three types of fan module are available: c 4 V, a 0 V and a 0 V. TSX FAN ppp One fan module is required for a TSX 7 05/08/0// configuration, two fan modules are required for a TSX 7 0// configuration with the TSX RKZ 0 mini rack. TSX 7 05/08/0 TSX TSX RKZ 0 TSX 7 08// TSX 7 / + TSX RKZ 0 () For an ambient temperature of between 5 C 60 C, the use of fan modules increases the MBTF. Description: pages 4050/ to 4050/ EN_Ver6.0.fm/7

7 Memory structure Memory structure The memory structure of TSX Micro PLCs consists of two distinct zones: b An internal RAM memory designed to receive the application (data, program and constants) of v Kwords for TSX 7 05/08 PLCs, v 4 Kwords for the TSX 7 0 PLC, v 0 Kwords for TSX 7 / PLCs. b A Flash EPROM memory of: v Kwords for TSX 7 05/08 PLCs, v 6 Kwords for TSX 7 0// PLCs designed to back up the application program ( or 4 Kwords maximum) and to back up 04 %MW internal words in the event of a battery failure or no battery. For TSX 7 / PLCs, the internal RAM memory can be extended via a, 64 or 8 Kwords PCMCIA memory card, either RAM or Flash EPROM. The same memory card incorporated the possibility of contained a storage zone for additional data, e.g. for production data and manufacturing recipes. PCMCIA memory extension cards for TSX 7 / PLCs These cards can be used to extend the PLC internal memory for storing the application program and constants. Two types of memory card are available: b Battery-backed RAM type memory card Used in particular during application program creation and debugging, this card enables all application transfer and modification services in online mode. The memory is backed up by a removable battery integrated in the memory card. b Flash EPROM type memory card Used when the debugging of the application program is complete, this card enables one global transfer only of the application and avoids the problems of backup via battery. A third type of card can also be used to store additional data: b Battery-backed RAM type memory card or battery-backed RAM and Flash EPROM Used particularly in association with the Modem link, these are used to extend the processor's internal memory, and also to store recipe or data log for later consultation via a telephone link. The RAM memory is backed up by a removable battery integrated in the memory card. Another type of PCMCIA memory card is available: b Backup type memory card (for TSX 7 / PLCs) Previously loaded with the application program, this card is used to reload the application program into the internal RAM memory and the internal Flash EPROM memory of the processor, without requiring the use of a programming terminal. Program loader The TSX PRG LDR module is designed to simplify duplicating or updating applications on Nano and TSX Micro PLCs without the need for a programming terminal. An application (5 Kwords maximum in internal RAM) can be transferred from a PLC in the TSX PRG LDR module (and saved within it), then transferred from the TSX PRG LDR module to the PLC The front panel of the TSX PRG LDR module comprises: A cord for connecting to the PLC terminal port. Four operation indicator LEDs. A W/R button which selects the program transfer direction (PLC V module or module V PLC). 4 AGObuttontostartthetransfer. 5 A Write Only switch which prevents PLC V module transfer. 6 A Program Protect switch which protects the PLC application as read-only after the transfer EN_Ver6.0.fm/8

8 Memory structure (continued) Application memory The application memory is divided into memory zones, which are physically shared between the internal RAM memory and the PCMCIA memory card (if the TSX 7 / PLC has a memory card): b The application data zone which is always is the internal RAM memory. b The application program zone in the internal RAM memory or on the PCMCIA memory card. b The constants zone in the internal RAM memory or on the PCMCIA memory card. b The Flash EPROM zone for the application program backup, the constants and K internal words. b The file storage zone in the PCMCIA memory card. If the content of the RAM memory is lost (battery fault or no battery) then the content of the Flash EPROM memory (program, constants and K internal words) is automatically transferred to the internal RAM memory. The backup copy of the application in the Flash EPROM memory requires that the PLC does not have a PCMCIA memory extension card and that the size of the program and the constants does not exceed 6 Kwords. Two types of application memory organization are possible for TSX Micro PLCs depending on whether the PLC is equipped with a memory extension in the form of a PCMCIA card: TSX 7 05/08/0// (without PCMCIA card) Backup copy Internal RAM Flash EPROM /4/0 Kwords /6 Kwords Application data (7.5 Kwords maximum). Descriptor and exedutable code for tasks. Constant words, initial values and configuration. TSX 7 / (with a PCMCIA card) Backup copy Internal RAM Flash EPROM PCMCIA card 0 Kwords 6 Kwords /64/8 Kwords 8 Kwords Data Program Constants Program and constants Kwords int. %MW Data Kwordsint.%MW Program Constants Additional data storage Application data (7.5 Kwords maximum). Descriptor and exedutable code for tasks. Constant words, initial values and configuration. 4 According to the PCMCIA card model. Application in the internal RAM The application is loaded entirely in the battery-backed internal RAM of the processor with a capacity of: b Kwords for TSX 7 05/08, shared, for example: as Kwords of application data and 8 Kwords of the program and its constants. b 4 Kwords for TSX 7 0, shared, for example: as 500 words of application data and.5 Kwords of the program and its constants. b 0 Kwords for TSX 7 /, shared, for example: as 4 Kwords of application data and 6 Kwords of the program and its constants. Application in the internal Flash EPROM The total volume is equal to the application volume in RAM, limited to Kwords or 5 Kwords, to which the backup of the first 04 data words (%MW) is added. Application in the PCMCIA card The PCMCIA memory card contains the program and the constants. The additional data storage zone for 8 Kword data (available according to the PCMCIA card model) can be used for distributed applications, for storing information which can be consulted remotely via Modem. This zone can also be used for storing manufacturing recipes. Internal RAM data The data zone can be extended to 0 Kwords, and is only held in the PLC internal RAM. Data backup The first 04 words are backed up by the PLC internal Flash EPROM memory. PL7 Micro/Junior/Pro software aids the application designer in the management of the structure and the occupation of memory space for TSX Micro PLCs. Application protection Whatever the PLC's memory structure is: application in internal RAM or on the PCMCIA card, it is possible to protect the structure to prohibit access (reading or program modification) in online mode using PL7 Micro/Junior/Pro software. Backup application Micro TSX 7 / PLCs make it possible to save the Kwords maximum application (programs and constants) on a Backup TSX MFP BAK 0P memory card. The internal RAM memory can thus be reloaded with the contents of this Backup memory card. This Backup function is not available if the application runs on a PCMCIA RAM or Flash EPROM memory card EN_Ver6.0.fm/9

9 Centralized display, description Centralized display TSX Micro PLCs are equipped with a display block which groups together centrally all the data required for the control, diagnostics and maintenance of the PLC and all its modules, as well as simple man-machine interface functions. The centralized display provides: b Display of the local or remote I/O channel states (I/O of Nano PLCs). b Display of devices on the AS-Interface bus and AS-Interface bus diagnostics (see 4/6). b Display of diagnostics of faulty channels or modules. b Display of internal data: v bits, v bit strings, v word strings, v program variables (active steps, application information, etc). b 4-digit multiple digital display. Description The centralized display block comprises: BASE 64 6 EXT R I/O WRD DIAG RUN Three blocks of LEDs representing the slots in which the modules are installed in the base rack or mini extension rack > s. DIAG TER I/O ERR 4 An information line consisting of LEDs which show the display operating modes. A command push button which provides access to the various display operating modes BAT 4 Five LEDs: v RUN, PLC run/stop, v TER, traffic on the terminal port, v I/O, I/O fault, v ERR, processor or application fault, v BAT, battery fault or no battery EN_Ver6.0.fm/0

10 Characteristics Characteristics TSX Micro PLCs have been developed to conform to the national and international standards concerning electronic devices for industrial control systems: b Specific requirements for programmable controllers: functional characteristics, resistance, robustness, safety, etc. IEC 6-, CSA -, UL 508. b Merchant navy requirements from the main European bodies: BV, DNV, GL, GOST, LR, RRS. b European directives (low voltage, electromagnetic compatibility), e marking. b Electrical qualities and self-extinguishing capacity of insulating materials: UL 746C, UL 94, etc. See page 4/. Environmental characteristics (characteristics common to all TSX Micro PLC components) Temperature Operation C ( conforming to IEC 6-), with TSX FAN ventilation modules Storage C (conforming to IEC 6-) Relative humidity Operation Storage 0 %...95 %, without condensation 5 %..95 % conforming to IEC 6/ without condensation Altitude m Mechanical withstand Resistant to vibrations Resistant to shocks Conforming to IEC 68--6, Fc test Conforming to IEC 68--7, Ea test Resistant to electrostatic discharge Resistance to HF interference Withstand to electrostatic discharge Conforming to IEC , level () Resistant to electromagnetic fields Conforming to IEC , level () Resistant to rapid transient bursts Conforming to IEC , level () Resistant to shock waves Conforming to IEC Resistant to damped oscillatory waves Conforming to IEC Resistance to LF interference Conforming to IEC 6- Power supply characteristics Type of power supply Power supply a Power supply c Primary Voltage Nominal V a c 4 Limit (including ripple) V a c 9...0V possible up to 4 V for hr per 4 hrs Frequency Nominal (limit) Hz (47-6) Current Nominal input A y 0.7 (a 00 V), 0. (a 40 V) Inrush () A y 60 y 60 Micro-breaks Accepted duration y / period, repetition s y 0 ms, repetition u s Secondary Power Total useful W 4 ( peak) 6 (8 peak) (typical) Output currents c 5 V output A.8 (. peak).8 (. peak) Protection integrated on the outputs against Output c 4 VR (for relay outputs) c 4 V output sensors A 0.5 (0.6 peak) A 0.4 (0.6 peak) Overloads Yes Yes Short-circuits Yes Yes Isolation Dielectric resistance Primary/ secondary Vrms /60 Hz No isolation, 0 V internal connected to the PLC ground () Minimum level in the test conditions defined by the standards. () Values to be taken into account when starting up several devices at the same time or when sizing protection devices EN_Ver6.0.fm/

11 Characteristics (continued) Processor chracteristics Type of PLc TSX 7 05 TSX 7 08 TSX 7 0 TSX 7 TSX 7 No. of slots Basic With extension rack, slots 4 5 Functions (Max.no.) Discrete I/ O() Screw terminal block 60 (8 I/O) 88 (56 I/O) 4 (8 I/O) 60 ( ) HE0 connector (8or64I/ 48 ( ) O) 64 channel modules Analog I/O Integrated 8IetO Modules 4 Type of modules Half format module 4 or 8 I, or 4 O, 4 I/O Regulation The number of loops is limited by the number of analogue modules and by the size of memory Counting Integrated channel 0 khz channels () Modules () 4 () Type of modules Half format module or channel 40/500 khz, channel SSI MHz Discrete I/O channels 500 Hz Integrated connections Networks and bus connections Serial link link with connector (TER) 9. Kbit/s link with connectors (TER and AUX) 9, Kbit/s Type of links Uni-Telway master/slave Modbus slave RTU Character mode Modbus master/slave RTU Character mode Ethernet TCP/IP (Ethernet TCP/IP external module or RS Modem) Fipway network, (4) Modbus Plus AS-Interface bus Half format module (profil M) (5) CANopen bus (4) Modbus bus, Uni-Telway, Characters string (4) (4) Extension by Nano base and Nano extension (00 m maxi) half-format module (5) for 96 discrete I/O or analogue I/O (4 Nano bases 4 I/O or analogue extensions I/ O) Real time clock Memory Max. Internal RAM which can Kwords 4 0 capacity be backed up Program and constants Kwords 8 with PCMCIA card Data storage Kwords 8 Max. data storage size Internal bits %Mi bits 56 Internal words %MWi Kwords (6) (6), 7,5 with PCMCIA card Constants words %KWi Words 8 (6) Application structure Master task Fast task Event processing 8 6 (where has priority) Execution time Without for instruction PCMCIA card With PCMCIA card No. of K instructions executed by ms Without PCMCIA card With PCMCIA card Boolean µs 0,5 0, On word or fixed-point arithmetic µs 4,8 4,50 Boolean µs 0,9 On word or fixed-point µs 4,50 arithmetic 00 % boolean Kinst/,0 5,88 ms 65 % boolean and 5 % Kinst/ 0,5 0,7 numerical ms 00 % boolean Kinst/ 4,00 ms 65 % boolean and 5 % numerical Kinst/ ms 0,66 Overhead système Master task ms,9,6, () The value in bracket and in italics corresponds to number of I/O providing with the basic PLC configuration. () Maximum number of couting/positioning channels, see page 4054/. () TSX CTZpp counting/positioning modules, only in the TSX Micro base. (4) PCMCIA to insert in the communication card slot (5) The remote discrete I/O extension modules and AS-Interface bus modules are installed in position 4 which means that their use is mutually exclusive. (6) Default size, can be extended, but will have an adverse effect on the size of the application program EN_Ver6.0.fm/

12 References Basic TSX 7 05/08 PLC configurations ( slot available) Power supply Integrated memories Integrated memory Discrete I/ Reference O modules RAM Flash Type Connection EPROM a V Kwords Kwords modules with 6 I c 4 V, O relay Via screw terminal block (supplied) Weight TSX DR.70 modules with 6 I c 4 V, O relay Via screw terminal block (supplied) TSX DR.70 TSX 7 05/0 p8pp Basic TSX 7 0 PLC configurations ( slot available) Power supply Integrated memories Integrated memory Discrete I/ Reference O modules RAM Flash Type Connection EPROM c 4 V 4 Kwords 5 Kwords module with 6 I c 4 V Solid state O 0.5 A Via screw terminal block (supplied) Weight TSX 7 0 8DT.870 module with 6 I c 4 V O relay Via screw terminal block (supplied) TSX 7 0 8DR.900 TSX708056DR module with ViaHE0type 6 I c 4 V connector Solid state O 0.5 A TSX 7 0 8DTK.740 module with ViaHE0type I c 4 V connector Solid state O 0. A TSX DTK.80 a V 4 Kwords 5 Kwords module with 6 I a 5 V O relay module with 6 I c 4 V O relay Via screw terminal block (supplied) Via screw terminal block (supplied) TSX AR.90 TSX DR.90 TSX7064DTK Basic TSX 7 / PLC configurations ( slots available) Power supply Integrated memories Integrated functions Reference Weight RAM Flash EPROM c 4 V 0 Kwords 5Kwords TSX analog inputs 0-0 V analog output 0-0 V Up/down counter 0 khz counter 0 khz TSX a V 0 Kwords 5 Kwords TSX TSX 7 p0 8 analog inputs 0-0 V analog output 0-0 V Up/down counter 0 khz counter 0 khz TSX Mini extension rack Capacity Use Number maximum Reference Weight slots(possibility of 4 positions) PLCs TSX 7 0// mini rack per PLC TSX RKZ Documentation TSX Micro base and module installation manual See page 490/ TSX RKZ 0 Description: pages 4050/ to 4050/ EN_Ver6.0.fm/

13 References (continued) TSX MRP pppp References (continued) Extension for application memory Use Memory size Reference Weight Application Data storage TSX 7 / Kwords TSX MRP 0P Kwords TSX MRP P Kwords TSX MRP 064P Kwords TSX MRP 64P Kwords TSX MRP 08P Kwords TSX MRP 8P Extension Flash EPROM PCMCIA memory Use Memory size Reference Weight Application Data storage TSX 7 / Kwords TSX MFP 0P Kwords TSX MFP P Kwords TSX MFP 064P Kwords TSX MFP 64P Kwords TSX MFP 08P TSX FAN ppp TSX PRG LDR Backup card () Use Memory size Reference Weight Application Data storage TSX 7 05/08/ 0 Kwords TSX MFP BAK 0P Fan modules Description Quantity to be used Supply Reference Weight Fan modules () for TSX 7 05/08/0// for TSX 7 0// with TSX RKZ 0 c 4 V TSX FAN DP a 00 0 V TSX FAN A4P a V TSX FAN A5P Separate parts Description Use Quantity Unity reference Weight Program loader with terminal port conn. cable Connection accessories Backup batteries Simplifies duplication, updating or backup of 5 Kwords applications (program) and constants in internal RAM (length: 0.m) TSX PRG LDR 0.50 Discrete I/O See page 405/0 Discrete I/O with Telefast See pages 405/ and 405/ Integrated analog I/O See page 405/7 Integrated counter channels See page 4054/5 TSX 7 05/08/0// internal RAM RAM type PCMCIA memory card TSX PLP Pack of 0 TSX PLP TSX BAT M Cover for empty slot Pack of 0 TSX RAZ Gripper Memory extension card (PCMCIA type ) TSX P CAP 0.00 () Card previously loaded to enable the TSX Micro application program to be updated without needing a programming terminal (the program must be entirely contained in the internal RAM). () One fan module for a TSX 7 05/08/0// configuration, two fan modules for a TSX 7 0/ / configuration with mini rack TSX RKZ 0. Required for an ambient temperature between 60 C and 70 C. () Cover to be mounted in positions which do not hold a module to obtain IP 0 level of protection. Description: pages 4050/ to 4050/ EN_Ver6.0.fm/4

14 Dimensions, mounting Dimensions, mounting Side view Front view Mounting 08, (),5 () 5 () 5 5 c a 7 b AF-AE4 J G H (4) 5,5 40 5,5 TSX 7 a b c TSX 7 G H J 05 08DR DR DR DR /8/64pp /8/64pp / p / p () Empty PLC () With screw terminal block ()WithHE0typeorSUB-Dconnectors (4)FixingholesforM4screws Mounting for TSX FAN ppp modules ,5 Installation regulations () 00 () () () () () 50 () 50 () () () u 50 mm () Switch gear or enclosure () Cable ducting or wiring clip Description: pages / to 050/ EN_Ver6.0.fm/5

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

Modicon Premium automation platform

Modicon Premium automation platform Modicon Premium automation platform Catalogue May 0 All technical information about products listed in this catalogue are now available on: www.schneider-electric.com Browse the product data sheet to check

More information

Modicon M340 PAC Improve process and energy management

Modicon M340 PAC Improve process and energy management Modicon M340 PAC Improve process and energy management Make the most of your energy SM When you need to achieve energy and productivity improvement objectives to create a single environment measuring energy

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules

More information

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5 - TFT - 96 MB Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis

More information

Modicon M340 The all-in-one PAC

Modicon M340 The all-in-one PAC Modicon M340 The all-in-one PAC Modicon PAC family Powered by Unity Modicon Quantum Process Automation Critical Infrastructures Modicon Premium Advanced Machines Manufacturing Large Infrastructures Modicon

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Modicon M340 Peripheral Remote I/O Adapter BMX PRA 0100 User Manual

Modicon M340 Peripheral Remote I/O Adapter BMX PRA 0100 User Manual Modicon M340 EIO0000000510 04/2014 Modicon M340 Peripheral Remote I/O Adapter BMX PRA 0100 User Manual 04/2014 EIO0000000510.04 www.schneider-electric.com The information provided in this documentation

More information

Disturbance Recoder SPCR 8C27. Product Guide

Disturbance Recoder SPCR 8C27. Product Guide Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Automation platform Modicon Premium. Catalogue

Automation platform Modicon Premium. Catalogue Automation platform Catalogue 00 A full range of catalogues for..... Safety Functions and Solutions using Preventa Catalogue 00/00 Detection Automation Automation Operator dialog Motion and Drives Global

More information

40.3. Control Relays and Timers

40.3. Control Relays and Timers .3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories

More information

Programming Logic controllers

Programming Logic controllers Programming Logic controllers Programmable Logic Controller (PLC) is a microprocessor based system that uses programmable memory to store instructions and implement functions such as logic, sequencing,

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

STRATO LED Drivers 70W, Single output

STRATO LED Drivers 70W, Single output Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED

More information

Configuring PROFINET

Configuring PROFINET CHAPTER 9 This chapter describes how to configure the PROFINET feature on the Cisco IE 3000 switch. Understanding PROFINET, page 9-1, page 9-4 Displaying the PROFINET Configuration, page 9-5 Troubleshooting

More information

Automation platform. Modicon M340 Simply the natural choice

Automation platform. Modicon M340 Simply the natural choice Automation platform Modicon M340 Simply the natural choice Leveraging ingenuity and intelligence for ease of use Modicon M340 The natural choice Modicon M340 springs from the ingenuity of Telemecanique

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

Automation & Control Modicon Premium automation platform

Automation & Control Modicon Premium automation platform Catalogue July 0 Automation & Control Modicon Premium automation platform Unity & PL7 Art. 8027 - MKTED2007EN Art. 67 - MKTED20EN Safety solutions using Preventa 200 Ethernet TCP/IP Transparent Factory

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

Automation platform Modicon M340 Simply the natural choice

Automation platform Modicon M340 Simply the natural choice Automation platform Modicon M340 Simply the natural choice Leveraging ingenuity and intelligence for ease of use Modicon M340 platform The natural choice Modicon M340 platform springs from the ingenuity

More information

Modicon Premium PLCs TSX 57/PCX 57 Communication Network and Bus Interfaces Installation manual Volume 4

Modicon Premium PLCs TSX 57/PCX 57 Communication Network and Bus Interfaces Installation manual Volume 4 Modicon Premium PLCs TSX 57/PCX 57 Communication Network and Bus Interfaces Installation manual Volume 4 eng May 2007 35009581_02 2 335009581 02 May 2007 Document Set Document Set At a Glance This documentation

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Communication Unit 560CMU05 Data sheet

Communication Unit 560CMU05 Data sheet RTU560 product line Communication Unit 560CMU05 Data sheet E1 10/100 MB LAN E2 10/100 MB LAN CP1, CP2 RS232C or RS485 Ethernet Controller Ethernet Controller USART Processor bus MPU ELAN520 /Flash Memory

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Series Six Plus Programmable Controller

Series Six Plus Programmable Controller Series Six Plus Programmable Controller Gl?K-0147B June 1989 Central Processor Unit 8-Slot Rack 1l-Slot Rack General Description The Central Processor Unit (CPU) for the Series Six Plus Programmable Logic

More information

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module

More information

Remote Monitoring and REC 501 Control Unit Product Guide

Remote Monitoring and REC 501 Control Unit Product Guide Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Repeaters and Mimics Data Sheet

Repeaters and Mimics Data Sheet Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.

More information

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection

More information

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved. SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Modular I/O system Rugged Modular I/O System Solutions EN-50155 certified for railway applications

Modular I/O system Rugged Modular I/O System Solutions EN-50155 certified for railway applications The systems and devices of the MODULAR I/O family are the Tecnint HTE solutions for industrial and technological application of automation, acquisition and management that require particularly robustness

More information

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1 BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM MAKING SMART TOWNS, BUILDING SMART COMMUNITIES WHY PANASONIC? RESIDENTIAL STORAGE BATTERY SYSTEM The next evolution in solar energy solutions. Panasonic

More information

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional

More information

... Electronic Softstarter...

... Electronic Softstarter... . CT-START Electronic Softstarter. 6 A. to 900. A......... CT START CT-START is a multi-function electronic system with a microcontroller and thyristors, designed for use with all 3-phase squirrel cage

More information

A-307. Mobile Data Terminal. Android OS Platform Datasheet

A-307. Mobile Data Terminal. Android OS Platform Datasheet A-307 Mobile Data Terminal Android OS Platform Datasheet Revision 1.1 July, 2013 Introduction A-307 Platform Overview Introduction A-307 Platform Overview The A-307 provides Original Equipment Manufacturers

More information

Optimize your simple machines... Modicon M218 Selection Guide

Optimize your simple machines... Modicon M218 Selection Guide Optimize your simple machines... Modicon M218 Selection Guide Compact Solution for Simple Machines Optimized Logic Controller Modicon M218 With intelligent software platform, specialized functional s,

More information

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053. PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection

More information

Programmable Controller G Series. New. Models

Programmable Controller G Series. New. Models Programmable Controller G Series The IMO G6 is a very compact modular programmable controller offering extremely high performance. It is ideal for all applications from process control to machine control

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8 CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection

More information

ABB RTU560A Series CMU & Modules

ABB RTU560A Series CMU & Modules ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power

More information

Model: DC-A2IO Advanced HVAC Controller

Model: DC-A2IO Advanced HVAC Controller Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4 Cable max. 50 m between interface and read/write head Connection of up to 4 read/write heads via BL ident extension cables Mixed operation of HF and UHF read/ write heads Connectors /S2500 Type code Ident

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

Operator dialogue terminals

Operator dialogue terminals Magelis text displays and operator terminals Characteristics : page /43 References : pages /44 to /46 General Design of the XBT-H/P/E range of display units and terminals Range XBT-H XBT-P XBT/H/P/E display

More information

MI4 - Operator Panel : Engineering

MI4 - Operator Panel : Engineering MI4 - Operator Panel : Engineering MI4 - Operator Panel : Engineering Overview MI4 Text Operator Panel MI4 Graphic Operator Panel MI4 Touch Operator Panel Communication modules Accessories MI4-CFG-1 Engineering

More information

IntesisBox KNX Modbus TCP master

IntesisBox KNX Modbus TCP master IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration

More information

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous

More information

MANUAL PC1000R INFO@APART-AUDIO.COM

MANUAL PC1000R INFO@APART-AUDIO.COM MANUAL PC1000R INFO@APART-AUDIO.COM Features The APart PC1000R is a professional multisource CD/USB/SD card music player, equipped with balanced and unbalanced analog outputs, coaxial and optical digital

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Automation Unit TM 1703 ACP Flexible automation and telecontrol Automation Unit Flexible automation and telecontrol Power Transmission and Distribution Outstanding performance: Automate simply with Highly complex and yet fully transparent automation solutions are not

More information

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Versions. Q.station Q.station T. Q.station D. Q.station DT x x Most important features: Very high data rates up to 100 khz each channel 100 khz at 16 channels, 10 khz at 128 channels 64 Q.bloxx modules connectable Ethernet interface for configuration and data output

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service

More information

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G 3891 0020

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G 3891 0020 Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G 3891 0020 Built-in Dupline channel generator PROFIBUS-DP slave according to EN 50 170 Certified by the PNO PROFIBUS-DP communication

More information

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common

More information

TSX Micro on support with sockets. Study and programming in PLC language

TSX Micro on support with sockets. Study and programming in PLC language TSX Micro on support with sockets Study and programming in PLC language TSX Micro on support with sockets 1. Presentation of the equipment The "TSX Micro on support with sockets" consists in a PLC TSX

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output NTA CPU board PROCESS INTERFACES NTA is a CPU board for STAR DualBus DCS systems. NTA provides the internal bus communication, managing all I/O boards of the STAR DualBus modular system. NTA also manages

More information

HVAC DRIVE H300 HVAC Drive for Building Automation

HVAC DRIVE H300 HVAC Drive for Building Automation HVAC DRIVE H300 HVAC Drive for Building Automation 1.0 hp - 450 hp (0.75 kw - 336 kw) 208 V - 230 V 400 V 575 V EMERSON Leading the world in climate technologies CONSIDER IT SOLVED. Emerson s promise to

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet switch Supports 10 Mbps/100 Mbps 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection 7/8" males, 5-pin, for power supply Separated power

More information

This Datasheet for the IC697CPM790. GMR Redundancy CPU, 486, 2K Triplex (voted) I/O. http://www.cimtecautomation.com/parts/p-14778-ic697cpm790.

This Datasheet for the IC697CPM790. GMR Redundancy CPU, 486, 2K Triplex (voted) I/O. http://www.cimtecautomation.com/parts/p-14778-ic697cpm790. his Datasheet for the GMR Redundancy CPU, 486, 2K riplex (voted) I/O. http://www.cimtecautomation.com/parts/p-14778-ic697cpm790.aspx Provides the wiring diagrams and installation guidelines for this GE

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850

More information

OZW30. Central Unit SYNERGYR

OZW30. Central Unit SYNERGYR 2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control

More information

How to read this guide

How to read this guide How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information

More information

FX07 Field Controller

FX07 Field Controller Product Bulletin FX07 Field Controller Issue Date March 25, 2008 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,

More information

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications Bar Code Reader Series BCL 20 A flexible reader for a variety of applications PRODUCT INFORMATION The benchmark for flexibility. Laser scanners of the BCL 20 series as variable as your requirements demand.

More information

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8 Type code Ident no. 1545007 Number of channels 8 Dimensions (W x L x H) 110.3 x 128.9 x 74.4 mm Cable max. 50 m between interface and read/write head 2 decimal rotary coding switches for the adjustment

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

1.44 kw Programmable DC Power Supplies XLN Series

1.44 kw Programmable DC Power Supplies XLN Series Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE T I A Training Document Page 1 of 25 Module This document has been written by Siemens AG for training

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Industrial Bar Code Scanners

Industrial Bar Code Scanners DS4800 Industrial Bar Code Scanners Enhanced Connectivity Ease of use Configuration SW Tool ACR4 technology Smart focus adjustment APPLICATIONS Automated warehousing Reading on pallets Picking systems

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS via PROFINET or AS-i 3.0 Gateways, via PROFINET or 2 / 1 Master, PROFINET / Slave AS-i Safety input slaves report via AS-i Safety output slaves switch via 1 Safety Monitor for 2 AS-i networks Operation

More information

PD 100A. Printing data system

PD 100A. Printing data system PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep

More information