Standard Steel Doors and Frames. Modular Masonry Construction
|
|
- Anastasia Reed
- 7 years ago
- Views:
Transcription
1 TECHNICAL DATA SERIES S D I Standard Steel Doors and Frames Masonry Construction 2014 Steel Door Institute STEEL DOOR INSTITUTE DETROIT ROAD CLEVELAND, OHIO 44145
2 SDI Standard Steel Doors and Frames Masonry Construction The Module Definition: The size of any individual part, taken as a unit of measure regular proportion. A basic unit of measure adopted by the uilding Industry as 4 inches. Concept: The use of a standard modular dimension common to building products such as masonry improves finished structure by the following: Increased accuracy, legibility, and simplicity of working drawings and contract documents. Added aesthetic flexibility induced by small unit standardization, allowing freedom of architectural design. masonry construction meets the architectural need blending and continuity of components. Non-modular units interrupt a geometric pattern, or flow, by virtue of the discontinuity of line. As a specific case, the use of a butted frame () is extremely important in stack bonded masonry unit construction. Any interruptions, such as cut units, unit lintels, wrap-arounds, etc, destroy the strong linear function of such details. Increased flexibility of finished structure through lower modification, addition, and renovation costs. Reduced overall material and labor costs by facilitating the use of standard practices and definable operating procedures. Interchangeability of materials is facilitated by the ability to substitute modular components. Estimating and takeoff simplified. Detailing and drawing coordination between trades and specialties simplified by small size standard grid. s: Concrete masonry units (CMU) have been standardized to an 8" high and 16" long module. Also available are half blocks standardized to a 4" high and 16" long module commonly used as a starter course shown on page 4. The availability of loose TEE or wire masonry anchors can be an advantage over fixed masonry anchors since they field adjust to masonry joints. bricks have been standardized to a 2 2/3" high and 8" long module, theree 6 bricks correspond to the modular size of CMU. This relationship is clearly shown on pages 3 and 4. Adjustments have been made in actual sizes to allow common size mortar joints 2
3 SDI Wrap Around Frame 6' 8" Door or 8' 0" Door Note: The masonry opening an 8 0 modular dimension opening and door opening height requires 12 courses of block or 36 courses of brick. Available in: X Standard Door Width 1 1* Single Swing Double Swing * May Vary ** opening = block width 0 +1/8 & Door Height 6' 8" A ** Detail Lintel as required Finish Floor Grid Masonry ** Notch masonry hardware provisions if required. SECTION A SECTION 3
4 SDI Wrap Around Frame 7' 0" Door X Available in: Standard Door Width 1 1* Single Swing Double Swing * May Vary ** opening = block width 0 +1/8 & Door Height 7' 0" A ** Detail Lintel as required 4" Starter Course Finish Floor Grid Masonry ** Notch masonry hardware provisions if required. SECTION A SECTION 4
5 utt Type Frame SDI ' 2" and 7' 10" Doors or 7' 0" Door (X) 4" Header Available in: X Standard Door Width Masonry 7' 4" Door Height 7' 0" A' Single Swing Double Swing Masonry 7' 4" and 8' 0" Door Height 7'-2" and 7' 10" A Finish Floor Grid 4" Sec. A' 7' 0" 7'2" and 7' 10" 2" Sec. A lock * SECTION A Detail Lintel as required *Single Rabbeted Frame Acceptable 2" * Masonry SECTION 2" 5
6 AVAILALE PULICATIONS MEMERS OF THE STEEL DOOR INSTITUTE Specifications ANSI/SDI A250.6 ANSI/SDI A250.8 SDI-108 SDI-118 SDI-128 SDI-129 Test Procedures Recommended Practice Hardware Reincings on Standard Steel Doors and Frames SDI 100 Specifications Standard Steel Doors & Frames Recommended Selection & Usage Guide Standard Steel Doors asic Fire Door, Fire Door Frame, Transom/Sidelight Frame, and Window Frame Requirements Guidelines Acoustical Permance of Standard Steel Doors & Frames Hinge & Strike Spacing ANSI/SDI A250.3 Test Procedure & Acceptance Criteria Factory Applied Finish Coatings Steel Doors & Frames ANSI/SDI A250.4 Test Procedure & Acceptance Criteria Physical Endurance Steel Doors, Frames and Frame Anchors ANSI/SDI A Test Procedure & Acceptance Criteria Prime Painted Steel Surfaces Steel Doors & Frames ANSI/SDI A Testing and Rating of Severe Windstorm Resistant Components Swinging Door Assemblies Protection of uilding Envelopes (Not applicable FEMA 320/361 or ICC-500 Shelters) SDI-113 Standard Practice Determining the Steady State Thermal Transmittance of Steel Door & Frame Assemblies SDI-131 Accelerated Physical Endurance Test Procedure Steel Doors, Frames and Frame Anchors Construction Details ANSI/SDI A Recommended Erection Instructions Steel Frames SDI-110 Standard Steel Doors & Frames Masonry Construction SDI-111 Recommended Details Standard Details Steel Doors, Frames, Accessories and Related Components SDI-122 Installation Troubleshooting Guide Standard Steel Doors & Frames Miscellaneous Documents SDI-112 SDI-117 SDI-124 SDI-127 SDI-130 SDI-134 Zinc-Coated (Galvanized/Galvannealed) Standard Steel Doors & Frames Manufacturing Tolerances Standard Steel Doors & Frames Maintenance of Standard Steel Doors & Frames Industry Alert Series (A-L) Electrified Hinge Preparations Nomenclature Standard Steel Doors & Steel Frames AUDIO-VISUAL PROGRAMS ALSO AVAILALE Ceco Door 9159 Telecom Drive Milan, TN (731) Curries P.O. ox 1648 Mason City, IA (641) Deansteel Manufacturing Co. 931 S. Flores Street San Antonio, TX (210) DOOR COMPONENTS INC Redwood Avenue Fontana, CA (909) HOLLOW METAL XPRESS 602 S. 65th Avenue Phoenix, AZ Mesker Door, Inc Stanwood oulevard Huntsville, AL (256) MPI 319 North Hills Road Corbin, KY (606) Pioneer Industries, Inc. 171 South Newman Street Hackensack, NJ (201) Republic Doors & Frames 155 Republic Drive McKenzie, TN (731) Security Metal Products 5700 Hannum Avenue, Suite 250 Culver City, CA (310) Steelcraft 9017 lue Ash Road Cincinnati, OH (513) STEEL DOOR INSTITUTE 12/4/ DETROIT ROAD CLEVELAND, OHIO FAX
Test Procedure and Acceptance Criteria for Factory Applied Finish Coatings for Steel Doors and Frames
ANSI/SDI A250.3-2007 (R2011) Revision of ANSI A250.3-1999 Test Procedure and Acceptance Criteria for Factory Applied Finish Coatings for Steel Doors and Frames ANSI/SDI A250.3-2007 STEEL DOOR INSTITUTE
More informationFact File. Compilation of SDI Technical Documents and ANSI/SDI Standards and Test Methods. Updated August 2016
Fact File Compilation of SDI Technical Documents and ANSI/SDI Standards and Test Methods Updated August 2016 Please visit www.steeldoor.org for the latest version of the Fact File. Steel Door Institute
More informationStandard Steel Doors, Frames, Accessories and Related Components
TECHNICAL DATA SERIES S D I 111-09 Recommended Details for Standard Steel Doors, Frames, Accessories and Related Components The information that follows represents the Standard Steel Door and Frame Industry's
More informationRecommended Erection Instructions for Steel Frames
ANSI/SDI A250.11-2012 Revision of ANSI/SDI A250.11-2001 Recommended Erection Instructions for Steel Frames ANSI/SDI A250.11-2012 SPONSOR Steel Door Institute Approved January 17, 2012 This page left intentionally
More information122-15. Installation Troubleshooting Guide for Standard Steel Doors and Frames STEEL DOOR INSTITUTE 30200 DETROIT ROAD CLEVELAND, OHIO 44145 S D I
TECHNICAL DATA SERIES S D I 122-15 Installation Troubleshooting Guide for Standard Steel Doors and Frames 2016 Steel Door Institute STEEL DOOR INSTITUTE 30200 DETROIT ROAD CLEVELAND, OHIO 44145 This page
More informationDoors and frames. Technical data manual 2015 rev. 8/17/15
Doors and frames Technical data manual 2015 rev. 8/17/15 Technical data manual Main table of contents NAVIGATE VIA: A) Rollover links in each TOC (each item below is a link), B) Bookmarks on the left,
More informationSteel Door Institute. Fire Rated Doors and Frames
Steel Door Institute Fire Rated Doors and Frames 1 1. Nomenclature and Overview 2. Fire Rated Frames 3. SDI 118 4. Fire Rated Doors 5. Fire Rated Hardware 6. Specialty Products Table of Contents 2 Fire
More informationDimensioning and Estimating Brick Masonry
TECHNICAL NOTES on Brick Construction 1850 Centennial Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 10 February 2009 Dimensioning and Estimating Brick Masonry Abstract: This Technical
More informationDIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS NOTICE TO BIDDERS BID FORM INSTRUCTIONS TO BIDDERS CONTRACTOR S BID FOR PUBLIC WORK - FORM 96 MINORITY AND WOMEN S BUSINESS ENTERPRISE PARTICIPATION
More informationn Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame
Weather Fin and bulb help keep bad weather outside and good air inside Windows: n Many light kits are available 1-LU 4 X 48 1-LE 16 X 16 1-LA 20 X 24 1-LI 20 X 24 1-B 22 X 36 1-LW 16 X 16 W/GRID 9-LB 22
More informationWhy Steel? Performance Study of Steel Doors and Frames Compared to Other Materials. September 2015. Sponsored by SDI, HMMA, CSDMA
Why Steel? Performance Study of Steel Doors and Frames Compared to Other Materials September 2015 Sponsored by SDI, HMMA, CSDMA CANADIAN STEEL DOOR MANUFACTURERS ASSOCIATION L'ASSOCIATION CANADIENNE DES
More informationSteel Door Frame Installation in Steel Stud Construction
Steel Door Frame Installation in Steel Stud Construction For use with the Steel Door Institute (SDI) video How to Install a Steel Door Frames in Steel Stud Construction This manual gives you step-by-step
More informationConstruction Masonry - Brick
Job Ready Assessment Blueprint Construction Masonry - Brick Test Code: 3125 / Version: 01 Measuring What Matters Specific Competencies and Skills Tested in this Assessment: Hand and Power Tools Identify
More informationFRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.
FRAME PROFILE MASONRY FLUSH MASONRY KD MITER CORNER JOINT Bend Tabs Head #8 Screw (MS002485) Required on all fire rated KD frames Corner Assembly 2" (50.8) Head Jamb Head Break Away Corner Clip Spot Welds
More informationRepair and Remodeling Estimating Methods. 4th Edition. RSMeans
Brochure More information from http://www.researchandmarkets.com/reports/2214808/ Repair and Remodeling Estimating Methods. 4th Edition. RSMeans Description: This estimating guide for repair and remodeling
More informationWHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
More informationHARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES
HOLLOW METAL MANUAL NAAMM STANDARD HMMA 831-11 8d NAAMM HMMA 831-11 METAL DOORS & FRAMES HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES 8d NAAMM HMMA 831-11 METAL DOORS & FRAMES A Division of HOLLOW
More informationPART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
More informationST. MONICA FOOD PANTRY HOUSTON, TEXAS
PROJECT MANUAL FOR ST. MONICA FOOD PANTRY HOUSTON, TEXAS OWNER: ST. MONICA CATHOLIC CHURCH 8421 W. MONTGOMERY ROAD HOUSTON, TEXAS 77088 ARCHITECT: C SIX ARCHITECTURE, LLC 4606 F.M. 1960 WEST, STE 400 HOUSTON,
More informationTechnical Data Honeycomb Door Leaf 8-1-99
8--99 8-/8 8-7/8 B 8-/4 A A Dim. A Leaf Width B ELEVATION F DESIGN Vertical edge seams mechanically interlocked Square hinge and lock edges 4-/ x.4 full mortise hinge prep Gov. 60/6 cyl lock prep...prefix
More informationBASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401
BASIC FIRE DOOR REQUIREMENTS SHEET NO. 401 Fire door openings are classified by their locations in the building. The location determines the length of exposure protection required, based on the potential
More informationDIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS
DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including general and supplementary conditions and other Division 1
More informationANSI A250.4 Test Procedure and Acceptance Criteria for Physical Endurance for Steel Doors, Frames and Frame Anchors
ANSI A250.4 Test Procedure and Acceptance Criteria for Physical Endurance for Steel Doors, Frames and Frame Anchors 1 Learning Session Description This training aid focuses on the revisions to ANSI A250.4-2011
More informationSpecifications for Standard Steel Doors and Frames (SDI-100)
Revision of ANSI/SDI A250.8-2003 Specifications for Standard Steel Doors and Frames (SDI-100) ANSI/SDI A250.8-2014 SPONSOR Steel Door Institute Approved June 2, 2014 This page left intentionally blank.
More informationDesign Development Quality Management Phase Checklist Project Phase Checklist Series
Best Practices Design Checklist Project Phase Checklist Series Contributed by Micheal J. Lough, AIA, Principal, Integral Consulting The AIA collects and disseminates Best Practices as a service to AIA
More informationLAYING BLOCK AND BRICK
LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct
More informationK. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11
K. D. FRAME ASSEMBLY FOR MASONRY WALLS...........................Ins 2 FRAME INSTALLATION DETAILS FOR MASONRY WALLS......................Ins 3 INSTALLING EXISTING MASONRY WALL ANCHORS IN FRAME..................Ins
More informationSECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
More informationADVANTAGES OF MODULAR LAYOUT
Brick Modules Section 2.1.3 Page 1 ADVANTAGES OF MODULAR LAYOUT Where possible, it is desirable to lay out the brickwork according to the module of the brick being used - both in length and in height.
More informationVOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10
VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 SECTION B1: PREPARATION GUIDE B1.1 INTRODUCTION... B1-1
More information2008-2009 Cost Comparisons for Common Commercial Wall Systems
An Independent Study LA MS KY TN AL GA SC NC FL 2008-2009 Cost Comparisons for Common Commercial Systems CAPITAL BUILDING CONSULTANTS PROFESSIONAL CONSTRUCTION ESTIMATORS 2008 2009 INDEPENDENT COST COMPARISONS
More informationSECTION 00 0110 TABLE OF CONTENTS. H. 00 2115.01 - Proposed Material, Product or Equipment Substitution Request
SECTION 00 0110 PROCUREMENT AND CONTRACTING REQUIREMENTS 1.1 DIVISION 00 -- PROCUREMENT AND CONTRACTING REQUIREMENTS A. 00 0101 - Project Title Page B. 00 0105 - Certifications Page C. 00 0110 - Table
More informationSAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT
SAMPLE SCHEDULE OF S 1.00 General Conditions 1.01 Project Management 1.02 General Superintendent 1.03 Superintendents 1.04 Safety Engineer 1.05 Scheduling 1.06 Field Engineering 1.07 Bonds 1.08 Trailer
More informationINSTALLATION INSTRUCTIONS
door frames Engineered product systems INSTALLATION INSTRUCTIONS door frames MINIMALIST DOOR FRAME Fry Reglet Flush Door frames are designed for use with 3 5/8 studs with ½ drywall both sides (4 5/8 throat
More informationBasic Fire Door Requirements
TECHNICAL DATA SERIES S D I 118-01 Basic Fire Door Requirements 2001 Steel Door Institute STEEL DOOR INSTITUTE 30200 DETROIT ROAD - CLEVELAND, OHIO 44145 Technical Data Series SDI 118-2001 Basic Fire Door
More informationGUIDELINES FOR REHABILITATION OF TRADITIONAL COMMERCIAL BUILDINGS DESIGN GUIDELINES
GUIDELINES FOR REHABILITATION OF TRADITIONAL COMMERCIAL BUILDINGS DESIGN GUIDELINES PAGE 13 DESIGN GUIDELINES The following design guidelines have been developed to guide appropriate design in the Downtown
More informationREDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES
REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES Tools Required Tape Measure Hammer Slotted Screw Driver #2 & #3 Philips Screw Driver 3-4 Foot Level 12 Pry Bar Cold Chisel
More informationQuality Building Products for over 50 Years
Light Commercial Quality Building Products for over 50 Years Harvey Building Products is a leading manufacturer and distributor of high quality building products. We manufacture a complete line of superior
More informationAutomatic Door Selection Guide
Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 aaadm@aaadm.com Automatic Door Selection Guide General: The members of AAADM manufacture an assortment
More information280+ Mortise Mounted Series Shear Locks Special Application Solution
280+ Mortise Mounted Series Shear Locks Power Plus control module overcomes gaps of up to 1/4" Low Temperature Operation 280+ TRD Locknetics provides the industry s most complete selection of electromagnetic
More informationPUBLIC RESTROOMS, DESIGN INTENT
PUBLIC RESTROOMS, DESIGN INTENT 1.01 STRUCTURAL A. Where feasible, metal stud partitions will be constructed on a 6 high concrete curb. 1.02 MECHANICAL A. Restrooms will have a minimum of 15 air changes
More information1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.
Formulas: Formula Letters: H= Height BCY = Bank Cubic Yards L= Length CCY = Compact Cubic Yards P= Perimeter LCY = Loose Cubic Yards LF = Linear Feet or Lineal Feet BF = Board Foot or Feet SF = Square
More informationCertification: Building Plans Examiner. Exam ID: B3
Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building
More informationA D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA
Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,
More informationFire-rated Aluminum Doors
Fire-rated Aluminum Doors Langebjergvænget 13 ALUFLAM has pioneered the innovative solution to what was long considered an impossible dream (and a barrier to truly beautiful commercial architectural design),
More informationThis directive establishes Department of Homeland Security (DHS) policy regarding the physical protection of facilities and real property.
Department of Homeland Security Management Directives System MD Number: 11030.1 Issue Date: 04/21/2003 PHYSICAL PROTECTION OF FACILITIES AND REAL PROPERTY I. Purpose This directive establishes Department
More informationArchitectural hardware consulting services
Architectural hardware consulting services Architectural hardware consulting services Door hardware may only be a small percentage of the cost of the design and construction process, but it encompasses
More informationSub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders
INTRODUCTORY INFORMATION TABLE OF CONTENTS 00 0101 PROJECT TITLE PAGE PROCUREMENT REQUIREMENTS (PROJECT MANUAL) Tab A - Invitation for Bids Tab B - Instructions to Bidders Tab C Bid Form for General Bids
More informationClassroom Door Security & Locking Hardware
Classroom Door Security & Locking Hardware The ability to protect students and teachers while in the classroom is a high priority in all educational institutions. Many schools and school districts have
More informationEggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art
D O O R F R A M E S Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art D O O R F R A M E S Eggers Industries
More informationEaton Customer Manufacturing Solution Centers (CMSC) Solutions for every industry
Eaton Customer Manufacturing Solution Centers (CMSC) Solutions for every industry Eaton Customer Manufacturing Solution Centers Experience unparalleled customer commitment Proven expertise Turnkey application
More informationDOORS HOLLOW METAL MANUAL NAAMM STANDARD NAAMM HMMA 810-09 METAL DOORS & FRAMES METAL. A Division of
HOLLOW METAL MANUAL NAAMM STANDARD HMMA 810-09 8d NAAMM HMMA 810-09 METAL DOORS & FRAMES HOLLOW METAL DOORS 8d NAAMM HMMA 810-09 METAL DOORS & FRAMES A Division of HOLLOW METAL MANUFACTURERS A S S O C
More informationInstallation S D I 122-99 TECHNICAL DATA SERIES. and Troubleshooting Guide. for Standard Steel Doors and Frames STEEL DOOR INSTITUTE
TECHNICAL DATA SERIES S D I 122-99 Installation and Troubleshooting Guide for Standard Steel Doors and Frames STEEL DOOR INSTITUTE 30200 DETROIT ROAD - CLEVELAND, OHIO 44145 Table of Contents Improper
More informationHOW TO ESTIMATE THE COST OF T-BAR
HOW TO ESTIMATE THE COST OF T-BAR ACOUSTICAL CEILINGS MICHAEL HILL DATE WRITTEN: MAY OF 2007 The author is Michael Hill, Estimator with Kaiser Foundation Hospitals, National Facilities Services Cost Engineering
More informationA Complete Solution CREATING WALLS THAT DEFINE SPACE
A Complete Solution CREATING WALLS THAT DEFINE SPACE COMPANY HISTORY CLIPPER WALL Clipper partitions are part of the Saint- Gobain Group, one of the worldwide leaders in the construction products industry.
More informationHow To Find Out What Happened To Slave Housing
Slave Housing Data Base Building Name: Presquisle Brick Duplex 2 (northern building) Evidence Type: Extant Site ID: Historical Site Name: City or Vicinity: County: Culpeper State: Virginia UTM: Easting:
More informationSecurity steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille
Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille Text example Compile and tender according to requirements. Please refer to technical data below for respective
More informationNatural Thin Stone Veneer
Natural Thin Stone Veneer Until recently, if a project called for the natural look of stone but could not support its weight or thickness, the options were limited to manufactured imitation stone. More
More informationBROWACOM PRODUCTS. Our web-pages can be found from: http://www.browacom.fi
BROWACOM PRODUCTS manufactures and sells telecom solutions for professional users. Products include CityCabinet-product family, as a service Browacom offers subcontracting services in electromechanical
More informationGuidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
More informationHollow or Cinder Block Wall Mount Job Aid
Summary This Job Aid covers: Hollow or Cinder Block Wall Mount Job Aid Hollow or Cinder Block wall Mount Bracket Installing the Mount Bracket into Cinder Block This Job Aid supports the Technician audience.
More informationNOTICE TO CONTRACTORS
NOTICE TO CONTRACTORS Notice is hereby given that San Luis Obispo County Community College District, ( District ) is accepting sealed Informal Bidding Prequalification Applications and Formal Bidding Prequalification
More informationVoted. by the National Association of Home Builders Survey and Builder Magazine
Several Stock or Custom Frame Colors To Choose From Real Glass Block Windows Voted Introduced nearly a decade ago, Vinyl Wrap was the first vinyl frame system available to the REAL Glass Block industry.
More informationBILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"
BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP" Sl. 1 DISMANTLING WORK 1.1 Stripping off worn out plaster (outside and inside) and raking out joints
More informationArchitectural Hardware Consulting Services
Architectural Hardware Consulting Services Door hardware may only be a small percentage of the cost of the design and construction process, but it encompasses 90 percent of what s touched in a building
More informationCity of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
More informationSECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
More informationCoursing Tables, Metric Shapes and Sizes
Coursing Tables, Metric Shapes and Sizes By Gary Sturgeon, B.Eng., MSc., P.Eng. Technical Services Engineer, CCMPA 3.1 The Anatomy of a Standard Concrete Block Masonry Unit A perspective view of a standard,
More informationSECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
More informationSOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
More informationAutobody/Collision and Repair Technology/Technician CIP 47.0603 Task Grid
1 Secondary Task List 100 ORIENTATION 101 Identify opportunities in the auto body field. 102 Identify basic auto body construction. 103 Identify program rules and policies. 104 Identify government agencies
More information3955-01 Santa Barbara Lounge 24W x 31H x 24D AH22
3955-01 Santa Barbara Lounge 24W x 31H x 24D AH22 T H E L O G I C w o r k O F F I C E S E R I E S h b f L O G I C w o r k O F F I C E S E R I E S A D A P T S T O E V E R C H A N G I N G W O R K P L A C
More informationCluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11
Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU
More informationChapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
More informationSample Calculations...V-CR-12. Door and Window Typical Combinations... V-CR-12 Horizontal and Vertical Typical Combinations...
SECTION DIRECTORY General Information Definitions...V-CR- Design Considerations...V-CR- Composite Configurations...V-CR-4 Design Considerations and Examples for Typical Window and Door Combinations...V-CR-5
More informationNomenclature for: Standard Steel Doors and Frames
ANSI/SDI A250.7-1997 (R2002) Revision and Redesignation of ANSI/SDI A123.1-1989 Nomenclature for: Standard Steel Doors and Frames ANSI/SDI A250.7-1997 STEEL DOOR INSTITUTE SPONSOR Steel Door Institute
More informationUnderstanding BS EN 771-3: Aggregate concrete masonry units
60 Charles Street, Leicester LE1 1FB Tel: 0116 253 6161 Fax: 0116 251 4568 Email: enquiries@cba-blocks.org.uk Website: www.cba-blocks.org.uk February 2006 Understanding BS EN 771-3: Aggregate concrete
More informationPRODUCT SPECIFICATIONS
LokSeam LokSeam 12" One of the most versatile architectural metal panels available today, LokSeam by ABC, is a snap-together, concealed fastener, standing seam roof system with a 13/4" tall vertical rib,
More informationGuidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
More informationHMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES
HOLLOW METAL MANUAL NAAMM STANDARD HMMA 810-87 8d METAL DOORS & FRAMES NAAMM 2 87 HOLLOW METAL HOLLOW METAL DOORS FOURTH EDITION NAAMM 2 87 8d METAL DOORS & FRAMES A Division of NATIONAL ASSOCIATION OF
More informationTriarch Products Over Various Interior Substrates
Triarch products work well over a variety of substrates, both for interior and exterior settings. This document will only discuss interior substrates and is not intended to be a technical discussion of
More informationVer. 2. Guide to. Inspecting Residential Brick Veneer
Ver. 2 Guide to Inspecting Residential Brick Veneer 1. A guide created by industry professionals. The knowledgeable staff at MASONPRO together with technical support from the Masonry Institute of Michigan
More informationCHAPTER 2 QUANTITY TAKE-OFF
CHAPTER 2 QUANTITY TAKEOFF The quantity takeoff is an important part of the cost estimate. It must be as accurate as possible and should be based on all available engineering and design data. Use of appropriate
More informationVestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, 90.1-2001, 90.1-2004]
Vestibule Case Study [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, 90.1-2001, 90.1-2004] Vestibule Requirement Intent Page 1 of 14 The primary intent behind the requirement for a vestibule is to reduce infiltration
More informationThe Building Group First Tuesdays First Saint Paul s Lutheran Church 1301 North LaSalle Street, Chicago, Illinois
Wiss, Janney, Elstner Associates, Inc. 10 South LaSalle Street, Suite 2600 Chicago, Illinois 60603 312.372.0555 tel 312.372.0873 fax www.wje.com The Building Group First Tuesdays October 2, 2012 Jason
More informationHow To Build A T7 Rack For Information Technology
THE NEXT GENERATION RACK FOR INFORMATION TECHNOLOGY THE RACK CABINET FOR INFORMATION TECHNOLOGY T7, THE HI-TECH HEART OF THE BLADESHELTER SYSTEM The real answer to the requirements of: Safety Versatility
More informationC31 Property Damage Appraisal
C31 Property Damage Appraisal Sample Exam IMPORTANT The time allowed for this exam is 3 hours. Total marks: 200 You must hand in this paper and any paper used for rough work to the supervisor when you
More informationAuthor Page. Henry Frondorf is a Cost Engineer for HGC Construction Co., a Cincinnati based general
Author Page Henry Frondorf is a Cost Engineer for HGC Construction Co., a Cincinnati based general contractor specializing in historic restoration. He began his career working for DG Frondorf and Associates
More informationTechnical Notes 3B - Brick Masonry Section Properties May 1993
Technical Notes 3B - Brick Masonry Section Properties May 1993 Abstract: This Technical Notes is a design aid for the Building Code Requirements for Masonry Structures (ACI 530/ASCE 5/TMS 402-92) and Specifications
More informationSlavic Village Building Condition Review
Slavic Village Building Condition Review Slavic Village Development May 8, 2015 Page 1 EXECUTIVE SUMMARY City Architecture was commissioned by Slavic Village Development to review five existing facilities
More informationSun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
More information17,280 square feet Overview:
CENTRAL OFFICE Located at 167 Boston Post Road, East Lyme, Connecticut, the Central Office was built in 1916 as the original Flanders Elementary School and remains connected to the current school. The
More informationBuilding Condition Assessment: 109-111 North Howard Street Baltimore, Maryland
KPA The Joint Venture of EBA Engineering, Inc. and Kennedy Porter & Associates, Inc. 4813 Seton Drive, Baltimore, MD 21215 Phone: (410-358-7171) Fax: (410)358-7213 Building Condition Assessment: Baltimore,
More informationInternational Greenhouse Company
Greenhouse Foundation Design As with any building, a good solid foundation is crucial for the long term durability and functionality of your greenhouse. A weak foundation will cause your greenhouse to
More informationStainless Steel Continuous Hinges
Stainless Steel Continuous Hinges Hager heavy duty continuous hinges offer proven reliability that can stand up to the daily rigors of high-traffic, high-impact areas. They re designed and engineered to
More informationInstallation Detailed installation instructions are provided which should be strictly followed.
Specification System 6 The Metal Technology Thermally-Broken Vertical Slide Window has been designed in such a way that its'attractive and clean lines will enhance all types of residential and commercial
More informationPackaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
More informationNovoferm Interior Doors and Frames Just what you re looking for
Novoferm Interior Doors and Frames Just what you re looking for Contents Novoferm interior doors 3 Super-Standard, Super-Plus, Super-Dekor and Super-Color interior doors 4 Also suitable for use as a magnetic
More informationWhite Paper FIRE DOOR INSPECTIONS, REPAIRS AND LABELING
INTRODUCTION When the 2012 edition of the Life Safety Code is adopted by the Centers for Medicare Services (CMS) the following accreditation organizations The Joint Commission, AOA Healthcare Facilities
More information14209-FUMC-DENTON - MONROE CENTER
1429-FUMC-DENTON - MONROE CENTER FPI PROJECT #1429 FUMC-DENTON - MONROE CENTER DENTON, TEXAS 7621 Architect Project #: 1329- Contract Date: 11/4/214 Completion Date: Superintendent: Miguel Esparza - 817.21.6523