1 Specification System 6 The Metal Technology Thermally-Broken Vertical Slide Window has been designed in such a way that its'attractive and clean lines will enhance all types of residential and commercial property. Various other profiles have been designed and incorporated allowing architects to achieve combinations of fixed lights and sliding sashes without the need for a seperate coupling mullion. Introduction The system can accommodate both 6mm single glazed and 24mm double glazed units. As with all Metal Technology systems, the vertical sliding window system is manufactured to exacting standards enabling economy to be combined with strength to give many years of aesthetic, trouble-free operation. Scope This specification defines materials, construction, finishes and size limits for vertical sliding windows. Materials Aluminium profiles are extruded from aluminium alloy 6060T6, T5 or T4 complying with the recommendations of BS1474. Where sections have a thermal break, this is polyurethane. Finishes The range of sections can be provided in either of the following ranges of finishes: 1. Anodised to BS1615 or BS Powder organic coated to BS6496 Construction Frame members are generally square cut (jamb bars have a 5 mitre at the bottom). Corners are assembled with stainless steel screws driven into grooves in the sections. All frame joints are sealed during construction against entry of water. Woven woolpiles and glazing gaskets are provided to resist the ingress of water. Glazing Wrap-around "U" gaskets are fitted around the glass and then the sash frames are assembled around the glass. Installation Detailed installation instructions are provided which should be strictly followed. Vertical Slide Fittings Sliding sashes are designed to be hung on spiral spring balances. These are designed to support the sash in any designated opening position. At the meeting rail the sashes are secured by means of a sash lock and keep. On windows over 1000mm wide two sash locks and keeps should be fitted. Size Limits Size limits are generally dictated by the weight of the sash, however as a general principal none of the following limits should be exceeded. (Where a window is close to any of the maximum limits Metal Technology should be consulted.) Max Window Width 1500mm Max Window Height 2500mm Max Sash Weight 43 Kg Performance All windows are designed to provide Class ll weather tightness as defined by BS6375 pt.1 and BS4873. Should increased performance be required a deeper cill and bottom rail are available. Please consult our sales desk for information. Development Our policy is to continually research the market for new and improved products. We must therefore retain the right to amend specifications without prior notice. It is recognised at Metal Technology that in some instances special sections may be required for particular projects. When this occurs it may be possible to produce special sections subject to there being sufficient quantity and adequate time.
2
3 VS119 VS121 VS124 VS123 VS122 VS130 VS128 VS133 VS134 VS131 VS132 VS117 VS116 VS139 VS115 VS151 VS137 VS152 VS138
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23 System 6... VERTICAL SLIDING WINDOW... Wind Loading... Loading chart for mullion Based upon simply supported theory. Def = 1/ Pa Pa VS Direction of Load Pa VS Ixx = mm Pa Mullion spans simply supported Pa Mullion centres Not to Scale METAL TECHNOLOGY LIMITED. This data sheet is issued subject to the condition that it shall not be reproduced without the consent of Metal Technology in writing. 08/94.
24 Wind Loading... System 6... VERTICAL SLIDING WINDOW... Loading chart for mullion Based upon simply supported theory. Def = 1/ Pa 600 Pa Pa Direction of load VS111 Ixx = mm Pa Pa Mullion spans simply supported Mullion centres Not to Scale METAL TECHNOLOGY LIMITED. This data sheet is issued subject to the condition that it shall not be reproduced without the consent of Metal Technology in writing. 11/93.
Plaisance 50. Windows and doors. Sapa Building System
Plaisance 50 Windows and doors Sapa Building System Plaisance 50 is a non-thermally broken system for aluminium windows and doors with a building depth. The system offers a wide range of inward and outward
Confort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
ISSUE 2. Installation Guide
ISSUE 2 Installation Guide Here at Slide and Fold, we LOVE our Bi-Fold Plus range of folding-sliding doors. We want to ensure that your customers love them too. So we have created a new, detailed installation
Plaisance 24. Sliding Systems. Sapa Building System
Plaisance 24 Sliding Systems Sapa Building System Plaisance 24 is Sapa s noninsulated sliding system for windows and doors. Available as one-, two-, three- and fourrail solution. Among its features, there
Series 602 MAGNUM Sliding Window DESIGNER SERIES
Series 602 DESIGNER SERIES DATE: NOVEMBER 2009 REPLACES: AUGUST 2003 DESIGNER SERIES Series 602 KEY EATURES / PERORMANCE CHARACTERISTICS Scale: NOT TO SCALE Designed to complement our existing high quality
Avantis 75. Windows & Doors. Sapa Building System
Avantis 75 Windows & Doors Sapa Building System Avantis 75 is a thermally broken three-chamber window and door system, which sets the highest standards of thermal insulation and stability. Avantis 75
Fire Resistant Systems
Fire Resistant Systems A R C H I T E C T U R A L A L U M I N I U M G L A Z I N G S Y S T E M S Fire Resistant Systems Introduction Kawneer are pleased to introduce two new comprehensive Fire Resistant
The complete answer to secondary glazing. High performance secondary glazing solutions for new and refurbished buildings
The complete answer to secondary glazing High performance secondary glazing solutions for new and refurbished buildings add extra performance with secondary glazing systems Secondary glazing is a fully
K17.11 DOOR BOLTS K17 DOORS 01.09.2013
K17 DOORS K17.11 01.09.2013 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - [email protected] - www.sobinco.com CONTENTS 1. Locking set series 86000...K17.11.03 2.
CDW Systems Ltd Contemporary Doors & Windows
CDW Systems Ltd Contemporary Doors & Windows The comprehensive product overview A complete specification guide to CDW Systems range of Aluminium windows, doors and curtain walling for commercial and residential
Installation Window Building In Details
Installation Window Building In Details INSTALLATION Photo courtesy of Rowe Aluminium DATE: NOVEMBER 2009 REPLACES: AUGUST 2003 INSTALLATION Installation Replaces: Scale: NOT TO SCALE Vantage snap-on couplers
Confort 160. Sliding Systems. Sapa Building System
Confort 160 Sliding Systems Sapa Building System Confort 160 is a high performance thermally insulated sliding window system, with a user-friendly slide action. The system, which has an attractive aesthetic
Series 456 Commercial Awning Window
Commercial Awning Window COMMERCIAL SERIES Photo courtesy of Hanlon Windows Australia DATE: MAY 2013 REPLACES: MARCH 2008 COMMERCIAL SERIES KEY FEATURES/PERFORMANCE CHARACTERISTICS Scale: not to scale
Glass partitions SFB 3074
Glass partitions SFB 3074 Our facade system SFB 3074 is innovative in its design. We have made a great effort to obtain an energy effective system. The future requirements regarding the economical use
Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values
Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values SFB 1074 is available in two versions. In the first version the profiles are insulated with 30 mm glass fibre reinforced
information information
Technicalinformation Technicalinformation technicalinformation SYSTEM 40C GENERAL GROPERTIES 1 Glazing: from 4 to 22 mm 2 E.P.D.M. Sealing Gasket 3 Efficent drainage of the vent section 4 Efficent chamber
TOPLIGHTS. NOTE: 2.4m high sliding doors are only available in certain configurations and sizes.
NOTE: 2.4m high sliding doors are only available in certain configurations and sizes. Eagle Sidelights & Toplights Sidelights and Toplights are designed to clip onto the Eagle patio door system. The Sidelights
How To Fit A Portman Door Leaf
Portman Sliding Door Gear Timber/Frames Doors Frameless Glass Doors Top track Portman top tracks are suitable for door leaves of up to 80kg as standard Material is 6063T6 aluminium alloy anodised to 15
REHAU TOTAL70 WINDOW AND DOOR SYSTEM SYSTEM DESCRIPTION. www.rehau.co.uk/windows. Building Solutions Automotive Industry
REHAU TOTAL70 WINDOW AND DOOR SYSTEM SYSTEM DESCRIPTION www.rehau.co.uk/windows Building Solutions Automotive Industry REHAU TOTAL70 THE MORE COMPLETE SYSTEM The REHAU TOTAL70 Window and Door System comprises
Product information. Schüco Window AWS 65. 03.2009/Web Schüco AWS 65 1-11
Schüco Window AWS 65 The basic window system, Schüco Window AWS 65, with a comprehensive range for imaginative designs, is particularly suitable for block constructions with a basic depth of 65 mm. Features
comar1,3,4 & 8 Ground Floor Treatment Innovative, integrated aluminium ground floor framing suites.
Uniclass EPIC L3811:P43 C421:X421 CI/SfB (21 4) Xh4 comar1,3,4 & 8 Ground Floor Treatment Innovative, integrated aluminium ground floor framing suites. The Parkside Group Ltd Unit 5, The Willow Centre
Clad Direct Glaze Window Installation Instructions
Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully
City of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
V80 HEAD DETAIL - SECTION VIEW DRAWING SCALE 1:2. Dwg. No. V10101. 13mm min. 85mm. 72mm 95mm 65mm. 26mm. 10mm 60mm 75mm. 135mm.
13mm min. 72mm 95mm 65mm 85mm 26mm 10mm 60mm 75mm 135mm 145mm V80 HEAD DETAIL - SECTION VIEW Dwg. No. V10101 Manually operated blind with gearbox showing 90 & 45 degree crank penetrations in section view.
How To Test For An Architectural Test
Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Rendered to: CORAL ARCHITECTURAL PRODUCTS SERIES/MODEL: PW 256 with Door Openings PRODUCT TYPE: Aluminum Impact Resistant Curtain Wall System
Series 3502 Thermal Series 3902 Fixed Thermal 3 1 4 Architectural Grade Horizontal Sliding Window
Windows Curtain Walls Entrances Storefronts Series 3502 Thermal Series 3902 Fixed Thermal 3 1 4 Architectural Grade Horizontal Sliding Window Configurations XO OX XOX Fixed Series 3502 retains an AAMA
Technical data sheet PVC Bi-fold doors
Standard Specifications White internally beaded, Deceuninck 3000 series profile 28mm Low-e toughened sealed units with argon gas Open in doors with white handles and hinges Tracks are fitted to the top
Specification Guide. SmartSash. Fenestration Solutions for Public Sector & Commercial Applications ARCHITECTURAL. D11 +D13:X725 CI/SfB (31.4)+(31.
Uniclass L411 +L413:P7114 EPIC D11 +D13:X725 CI/SfB (31.4)+(31.5) Xn6 9/11 SmartSash A BRAND OF THE VEKA UK GROUP Specification Guide Fenestration Solutions for Public Sector & Commercial Applications
581 Double Hung. Features. Windows 581 Double Hung. Options. Limitations
581 Double Hung Features Windows 581 Double Hung The series 581 double hung window offers superb ventilation control and easy, rattle free operation. Whether renovating your existing home or building a
TEST REPORT. Report No.: B3404.01-801-47. Rendered to: CROFT, LLC. Magnolia, Mississippi. PRODUCT TYPE: Aluminum Single Hung Window SERIES/MODEL: 95
Architectural Testing TEST REPORT Report No.: B3404.01-801-47 Rendered to: CROFT, LLC. Magnolia, Mississippi PRODUCT TYPE: Aluminum Single Hung Window SERIES/MODEL: 95 SPECIFICATION: AAMA/WDMA/CSA 101/I.S.2/A440-08,
IAN BENNIE AND ASSOCIATES TEST REPORT NO. 2014-023-S2 AWNING WITH FIXED WINDOW PROTOTYPE TEST to AS2047-1999. for. Finesse Window Systems Australia
IAN BENNIE AND ASSOCIATES TEST REPORT NO. 2014-023-S2 AWNING WITH FIXED WINDOW PROTOTYPE TEST to AS2047-1999 for Finesse Window Systems Australia November 2014 Accreditation No. 2371 Accredited for compliance
CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED
CERTIFICATE OF APPROVAL No CF 291 This is to certify that, in accordance with TS General Requirements for Certification of Fire Protection Products The undermentioned products of Drummond Road, Stafford.
Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems
Dow Corning A Thermal Modelling Comparison of Typical Curtain Wall Systems Introduction Today s Aim To understand the meaning of a U value and window energy ratings Discuss the drivers for energy efficiency
Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa
Profiles in stock Standard catalogue Discover the possibilities with aluminium from Sapa You can create your own profile or you can choose from a wide selection of standard. Delivery: 1 2 weeks for standard
Window Repair & Replacement in Conservation Areas
Window Repair & Replacement in Conservation Areas Introduction Conservation Areas are areas of architectural or historic interest, the character or appearance of which it is desirable to preserve or enhance.
Vertical Slider. Technical Manual. Issue E September 2006 Part No. 994610
Vertical Slider Technical Manual Issue E September 006 Part No. 994610 Issue E Ammendments Page No. Ammendment. 700618 & 700619 fringe seals added.. 133500 & 137500 bottom seals replaced with 13350 & 13750..
CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI
CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI The Company Founded in 1973 by Mr Imes Tinti in association with his son Vanni Tinti. In 1999 the locksmith workshop became a modern industrial company
Evidence of Performance. Class 2. Class 5A. Class C4 / B4. Test Report No. 15-003655-PR01. ift Rosenheim 16.12.2015
Evidence of Performance Test Report No. 15-003655-PR01 (PB-A01-02-en-01) Client Product Designation Performance-relevant product details Overall dimensions (W x H) Special features Alüminyum San. Tic.
SERIES 3000/4000 DOUBLE SLIDER AND DOUBLE HUNG WINDOWS. Craftsmanship. Style. Performance.
SERIES 3000/4000 DOUBLE SLIDER AND DOUBLE HUNG WINDOWS Craftsmanship. Style. Performance. A Double Advantage Double slider and double hung window sashes both open for greater control of air movement The
Peninsula Place, Greenwich, London
Concepts Products Service Peninsula Place, Greenwich, London 1 Project Report Peninsula Place, Greenwich, London Designed as one of the most sustainable commercial buildings in the UK, with a BREEAM rating
Aluminium systems profile selection
Aluminium systems profile selection The purpose of this document is to summarise the way that aluminium profile selection should be made, based on the strength requirements for each application. Curtain
PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB
OVERVIEW TYPE: GGB All composite construction Rigid extruded upvc aerofoil blade section Integral blade seals for low leakage operation Individual blades driven via reinforced styrene gear wheels in maintenance
JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC 97909-071 085113 ALUMINUM WINDOWS Guide Specs
JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC 97909-071 085113 ALUMINUM WINDOWS Guide Specs SECTION 085113 ALUMINUM WINDOWS This suggested guide specification has been developed using the current edition
n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame
Weather Fin and bulb help keep bad weather outside and good air inside Windows: n Many light kits are available 1-LU 4 X 48 1-LE 16 X 16 1-LA 20 X 24 1-LI 20 X 24 1-B 22 X 36 1-LW 16 X 16 W/GRID 9-LB 22
Product Management - Glass ALEXA PRODUCT PRESENTATION. Region SAARC Nitin Lloyd, Product Management. Chennai, FY 2013 / 2014
Product Management - Glass ALEXA PRODUCT PRESENTATION Region SAARC Nitin Lloyd, Product Management Chennai, FY 2013 / 2014 PRODUCT MANAGEMENT - GLASS Alexa Partitioning Systems DESIGN: Slim Profile system
Standard Door Specification
Element General Requirement To be defined in the project brief but should meet Building Regulations. All doors to be a minimum of 30 minute fire rated and must comply with all relevant UK legislation and
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
SHIELD NATIONAL OFFICE MELBOURNE 2-4 Freight Drive, Somerton, VIC 3062 Ph: 03 8339 2252
SHIELD NATIONAL OFFICE MELBOURNE 2-4 Freight Drive, Somerton, VIC 3062 Ph: 03 8339 2252 SHIELD DOORS & SYDNEY 4 Alban Street, Lidcombe NSW 2141 Ph: 02 9748 7005 UPTONS HOBART 312 Argyle Street, North Hobart,
vinyl replacement windows LOOKING FOR VINYL REPLACEMENT WINDOWS? Standard Features easy, trouble-free operation. window material formulated and
vinyl replacement windows LOOKING FOR VINYL REPLACEMENT WINDOWS? We are confident that we carry a style and size to suit your application. You can be sure that your investment will add value to your home,
Size & Range. for windows & doors. Company
Size & Range for windows & doors A Company B General information windows and doors Sizes This catalogue contains all Airlite s standard sizes for windows and doors. These are the ones that we make every
Initial Type Testing Report
Centrum stavebního inženýrství a. s., Praha Centre of Building Construction Engineering, Inc., Prague Accredited Testing Laboratory, Authorised Body, Notified Body, Certification Body workplace Zlín -
INDEX. Chapter8. air master. Perforated Ceiling Diffusers
Chapter8 INDEX A. Perforated ceiling diffuser 1. Perforated ceiling diffuser with plenum box..: APCD+P...8.1. Perforated ceiling diffuser with damper....: APCD...8. Standard sizes...8. Fixing details...8.
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
How-To-build guide timber windows
How-To-build guide timber windows What you can build using this guide This guide shows you how to install a factory-made timber casement window into a house with a weatherboard cladding. Casement windows
TRADITIONAL CASEMENT WINDOWS
TRADITIONAL CASEMENT WINDOWS Design Guide Timber casement windows succeeded the stone mullioned window, to become the most common window type by the second half of the eighteenth century. The traditional
Quality Building Products for over 50 Years
Light Commercial Quality Building Products for over 50 Years Harvey Building Products is a leading manufacturer and distributor of high quality building products. We manufacture a complete line of superior
CI/SfB. (31.59) X NOVEMBER 2003 Coburn Interior Sliding Systems
Uniclass L4181 EPIC D181 CI/SfB (31.59) X NOVEMBER 2003 Coburn Interior Sliding Systems Interior Sliding Door Gears FOR CUPBOARDS, WARDROBES, INTERIOR SLIDING AND FOLDING DOORS A comprehensive range of
Casement/Awning Window Parts Reference Catalog
Casement/Awning Window Parts Reference Catalog (Includes Miscellaneous Parts for Eyebrow Casement and Garden Bay Windows) #1028654 (Revised 03/02) Weather Shield Mfg., Inc. Medford, WI 54451 715/748-2100
WINDOW INSTALLATION GUIDE
WINDOW INSTALLATION GUIDE is not responsible for or liable for any use or misuse of the information contained in this window installation guide. Window Installation Guide This guide provides basic information
Sun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin americancraftsmanwindows.com Project Requirements: Failure to follow these instructions may void product
K17.12 Door closers K17. Doors 01.09.2013
K17 Doors K17.12 01.09.2013 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - [email protected] - www.sobinco.com Contents 1. OPTIC door closer TS40(V) with scissor
7. Installation. installation 7.1.1. CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME
7. Installation Window involves the fixing of window frame at an earlier construction stage and subsequent of the window sashes. This is a highly workmanship dependent process. Only trained and approved
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
NATURAL SUSTAINABLE SECURE ENERGY EFFICIENT LOW MAINTENANCE IMPROVING WELL BEING
NATURAL SUSTAINABLE SECURE ENERGY EFFICIENT LOW MAINTENANCE IMPROVING WELL BEING IMPROVING WELL BEING 30 YEAR ROT & FUNGAL PROTECTION 10 YEAR IRONMONGERY GUARANTEE 10 YEAR PAINT FINISH WARRANTY 10 YEAR
HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL
HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL Please read these instructions carefully and completely before attempting to install Hale Pet Doors; they will guide you through the steps
Installation Instructions
Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step
anatomy of a window lintel architrave inner staff bead top rail lintel upper sash glazing bar meeting rails horn pane lower sash reveal
windows introduction Windows make a vital contribution to the character and appearance of historic buildings.the insertion of modern windows can completely ruin the look of a traditional building and considerably
Innovation Beyond Double Glazing
Innovation Beyond Double Glazing FIREGUARD 40 TM SERIES Innovation driven by passion On Guard NEW MIGLAS FIREGUARD 40 TM FIRST FULLY TESTED UNSCREENED BUSHFIRE RESISTANCE WINDOW FIRST WINDOW USING VIRIDIAN
SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS
Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications
Sample Calculations...V-CR-12. Door and Window Typical Combinations... V-CR-12 Horizontal and Vertical Typical Combinations...
SECTION DIRECTORY General Information Definitions...V-CR- Design Considerations...V-CR- Composite Configurations...V-CR-4 Design Considerations and Examples for Typical Window and Door Combinations...V-CR-5
Hürriyet Mah. Dr. Cemil Bengü Cad. No.27/A 34403 Çağlayan / Istanbul
Hürriyet Mah. Dr. Cemil Bengü Cad. No.27/A 34403 Çağlayan / Istanbul Tel: +9 0212 224 2392 +9 0212 225 2182 Faks:+9 0212 225 0274 Website: www.alaks.com.tr E-Mail: [email protected] 1160F Aluminum Corner
Security Shutters, Retractable Security Gates, SeceuroBar & Aluminium Folding Shutter
Security Shutters, Retractable Security Gates, SeceuroBar & Aluminium Folding Shutter C38 Vision 38 showing in-line punching Continental Range Experience Syston Doors have been manufacturing & supplying
Application for a Window Replacement Master Plan Curtis B. Wayne, Architect Ken Lustbader, Preservation Consultant
Application for a Window Replacement Master Plan Curtis B. Wayne, Architect Ken Lustbader, Preservation Consultant 37 West 12 th Street Between 5 th and 6 th Avenues Architectural History Architectural
ΑΡΧΙΤΕΚΤΟΝΙΚΑ ΣΥΣΤΗΜΑΤΑ ΑΛΟΥΜΙΝΙΟΥ ARCHITECTURAL ALUMINIUM SYSTEMS
ΑΡΧΙΤΕΚΤΟΝΙΚΑ ΣΥΣΤΗΜΑΤΑ ΑΛΟΥΜΙΝΙΟΥ ARCHITECTURAL ALUMINIUM SYSTEMS NORMAL SLIDING and SLIDING WITH THERMAL BREAK A L U M IN IU M S Y S T E M S 32 SERIES 32 SLIDING. : 9045 815 gr/m 475 mm -25-25 - FOR
Manual on Door and Window Details for Residential Buildings. Volume-1. Govt. of India Central Public Works Department
Manual on Door and Window Details for Residential Buildings Volume-1 Govt. of India Central Public Works Department 2006, Central Public Works Department No part of this publication can be reproduced in
Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.
Breezway Altair Powerlouvre Window 35 Breezway Altair Powerlouvre Window The Powerlourve Window motor is neatly concealed within the Easyscreen TM Frame or the Component Powerlouvre Head Section. Automated
WINDOW REPAIR MANUAL & REFERENCE GUIDE
WINDOW REPAIR MANUAL & REFERENCE GUIDE TABLE OF CONTENTS DOUBLE HUNG & SINGLE HUNG PARTS 4-5 CASEMENT PARTS 6 SCREEN PARTS 7-8 HOW TO REMOVE TILT-IN SASH 9 HOW TO REMOVE A BALANCE 10 HOW TO INSTALL BALANCE
Installation Instructions and Ordering Information
The Flush Finish Trimless Door Frame Installation Instructions and Ordering Information CLEAN LINES! The Flush Finish Door Jamb System Manufactured by STUDCO Building Systems Step 1 Verify if you are using
contents classic 3 switch 4 mini swing 5 sign wedge 6 chalkboards 7 all purpose A frames 8 H2O swingmaster 9 café banner 10 vision 11
the sign selection pavement swing signs pavement foil signs A boards forecourt signs pavement banner stand systems A frame banners promotion units snapframe signage suspended poster rails contents PAVEMENT
ARCHITECTURAL ALUMINIUM GLAZING SYSTEMS
ARCHITECTURAL ALUMINIUM GLAZING SYSTEMS Company Profile 2 Doors and Framing Systems 4 Curtain Wall Systems 5 Window Systems 6 Our Network 7 Value through Design ACS Limited specialise in the design, manufacture
CLAIM FORM APPENDIX. I. Photographs Identifying The Windows
CLAIM FORM APPENDIX I. Photographs Identifying The Windows The Settlement provides compensation for MIWD Products that are glazed with Glazing Tape and were manufactured or sold between July 1, 2000 and
Approved Document Q: Security
Approved Document Q: Security Requirement Q1 Unauthorised access Consultation draft September 2014 1 The approved documents What is an approved document? The Secretary of State has approved a series of
EVEN FOR SMALL QUANTITIES WE GET STARTED RIGHT AWAY...
EVEN FOR SMALL QUANTITIES WE GET STARTED RIGHT AWAY... Because we produce in-house, so we don t have far to go. Our decisions are not based on when and who can do what in Asia; instead, we look at what
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
The WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 2 of 60 Contents Overview 5 Objective 5 Scope 5 Opening Preparation 7 Step P1 Preliminary Check 8 Step P2 Cut the Underlay 9 Step
Side Hinged Doors GSW 40-L
Side Hinged Doors GSW 40-L GARAGE DOORS AND SIDE DOORS IN A WIDE RANGE OF DESIGNS NUMEROUS FINISHES, SURF ACES, COLOURS AND GLAZING ELEMENTS Extremely robust and highly insulating Superior quality Teckentrup
security solutions for your home
security solutions for your home www.prowlerproof.com.au Copyright 2004 Gershwin Pty Ltd ABN 220 641 02816 PRODUCT APPLICATIONS PRODUCT RANGE Prowler Proof manufactures a full range of products to suit
MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up
MOCK-UP TEST REPORT Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up Report No: 85616.01-120-32 Test Completion Date: 01/15/09 Report Date: 02/11/09 Record Retention End Date: 01/15/13
ENERGY EFFICIENT WINDOWS & DOORS A GUIDE TO THERMAL PERFORMANCE. www.rehau.co.uk. Building Solutions Automotive Industry
ENERGY EFFICIENT WINDOWS & DOORS A GUIDE TO THERMAL PERFORMANCE www.rehau.co.uk Building Solutions Automotive Industry INTRODUCTION IMPROVING THE ENERGY EFFICIENCY OF WINDOWS AND DOORS Background Environmental
Aluminium Standard. Technical Data. Included in delivery
luminium Standard UL / cul Robust aluminium enclosure for mechanical engineering and automation technology Fixing options for s and mounting plates Usable in wide temperature area Technical ata aterial:
MagTek A. Aluminium Manual Attack Resistant Doors
MagTek A Aluminium Manual Attack Resistant Doors MANUAL ATTACK-RESISTANCE Gunnebo s manual attack resistant doors have been designed to satisfy the ever increasing need to protect people, property and
Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)
THE B6 GLAZING SYSTEM GLAZING SYSTEMS FOR SEPTEMBER 2013 THE B6 HEEL BEAD SEAL SECURITY GLAZING SYSTEM Page 1 DESCRIPTION The B6 Heel Bead Seal Security Glazing System is suitable for installing all types
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
Automatic Door Selection Guide
Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 [email protected] Automatic Door Selection Guide General: The members of AAADM manufacture an assortment
Installation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
Q-Lon foam weatherseal: for PVC, timber and aluminium applications THE WORLDS BEST WEATHERSEAL
Q-Lon foam weatherseal: for PVC, timber and aluminium applications THE WORLDS BEST WEATHERSEAL CONTENTS About Schlegel 3 Q-Lon Profiles PVC doors, windows and roller shutters 6 Timber doors and windows
Colonnade Security Pipe
Description: Round & Square downpipe formed from extruded 6060 T4 aluminium in various sizes (Ø83mm, Ø108mm, 83x83 mm & 108x108mm*) & supplied with a complete range of accessories i.e. Offsets, bends,
SL30-ISO PROFILE SYSTEM
AESTHETICS AND sustainability SL30-ISO PROFILE SYSTEM TECHNICAL DOCuMENTATION WWW.MHB.NL SL30-ISO PROFILE SYSTEM 1. SL30-ISO and SL30-ISO-PLUS Sustainability is getting worldwide more and more the attention