SUBJECT: HYDRAULIC CHECK VALVES AND FLOW CONTROL VALVES
|
|
|
- Nathaniel Oliver
- 9 years ago
- Views:
Transcription
1 SUBJECT: HYDRAULIC CHECK VALVES AND FLOW CONTROL VALVES ABOUT THE SESSION This session deals with check valves, flow control valves, its functions, operations and application. INTRODUCTION Check Valve: Check Valve allowed free flow in one direction. Pilot Operated Check Valve: Pilot Operated Check Valve allows reverse flow, when a pilot pressure signal is applied to the pilot port. Flow Control Valve: Serve to influence the speed of movement of users by restricting the oil flow.
2 TABLE OF CONTENTS 1. Check Valve 2. Pilot Operated Check Valve 2.1 With External Drain Port 2.2 With Internal Drain Port 3.0 Flow Control Valve 3.1 Throttle Valve. 3.2 Double Throttle / Check Valve. 3.3 Fine Throttle as Cartridge Unit. 3.4 Flow Regulating Valve Directional Flow Regulating Valve 4.0 Flow control valve fitment methods.
3 OBJECTIVES: To understand in depth the function and operations of (i) Check valve (ii) Pilot operated check valve (iii) Throttle valve (iv) Flow control valve
4 1.0 CHECK VALVES Function In a hydraulic system, shut-off valves serve to check flow in a preferred direction and allow free flow in the opposite direction. They are designated as check valves. The shut-off valves are designed as poppet valves and therefore provide leak free closure. A ball or poppet is generally used as the closing element. The sectional diagram shows a simple check valve (as in the photo), where the closing element is a poppet 1, which is pushed on to the seat 3 in the housing by means of the spring 2. The mounting position for this valve is optional, since the spring always holds the closing element on the seat (fig. 1). When there is flow through the valve in the direction of the arrow, the poppet is lifted from its seat by the fluid pressure and allows free flow. In the opposite direction, the spring and the fluid push the poppet onto the seat and close the connection. The cracking pressure depends on the spring selected, its compression and the pressurized poppet surface area, and is generally between 0.5 and 3 bar, depending on the application. Valves with a low cracking pressure are used at present to by-pass a throttle position in one direction. When used as a by-pass valve to by-pass a return line filter, cracking pressure of, for example, 3 bar is found suitable to limit the pressure reached due to contamination. A check valve without spring must always be fitted vertically. The closing element then remains on the seat in the no flow condition due to gravity. It should be mentioned that the closing element can also be a disc or, for example, a hollow poppet.
5 Important Technical Data Size 6 to 150 Flow up to 15,000 1/min (at voil = 6 m/sec.) Operating pressure up to 315 bar Cracking pressure without spring: 0.5; 1.5 or 3 bar The so-called rectifier circuit is achieved by corresponding arrangement and connection of 4 check valves. It is used mainly in connection with flow control valves. With this circuit, the fluid must flow through the valve in the same direction at forward flow (red) and return flow (green) (figs. 2 and 3.)
6 2.0 PILOT OPERATED CHECK VALVE 2.1 Pilot operated check valve with external drain port The sectional diagram shows valve type SL, with drain port and pilot opening poppet. The difference between valve type SV is the addition, at drain port Y. The annulus area of the control spool is separated from port A. Pressure at port A affects only surface A 4 of the control spool (fig.6) Control pressure required at port X: pst = p1 A1 P2 (A1 A4) + C A 3 The circuit shows that, with pilot operation, part A is pressurized by a pre-switched throttle valve (fig.7) In this case, a pilot operated check valve with external drain port is necessary. Pilot operated check valves
7 Left: pilot operated check valve with threaded connections. Right: double throttle/check valve, sandwich plate design As opposed to the single check valves, pilot operated check valves can also be opened in the direction of closure. The valves are used, for example: - to seal working circuits under pressure - as a protection against the load dropping, if a line should break - against creep movements of hydraulically stressed users.
8 2.1 Pilot operated check valve with internal drain port The sectional diagram shows valve type SV, without drain port, with opening poppet. Symbol for valve type SV A1 = main poppet surface area (cm 2) A3 = control spool surface area (cm 2) C = co-effection for spring and friction (bar) A K = piston surface area at cylinder (cm 2) A R = annulus area at cylinder (cm 2) F = load at cylinder (da N) A 2 = surface area of pilot unloading poppet
9 The following circuit diagram shows once again the conditions given for control pressure in the equation (fig.5) It also shows that valve port A must be without pressure for pilot operation,. Pressure at port A would work against control pressure at the control spool. There is free flow in direction A to B, from B to A the main poppet 1 with pilot poppet 2 is held on its seat by system pressure in addition to the spring 3 (fig.4). When pressure affects control port X, the pilot spool 4 is pushed to the right, Firstly the pilot poppet 2 and then the main poppet 1 are thus pushed from their seats. Oil can now flow through the valve from B to A also. The pilot spool causes a cushioned decompression release of the fluid under pressure. There are therefore no switching oscillations. A certain minimum pilot pressure is required, so that the valve can also be safely controlled by means of the control spool. Required pilot pressure at port X: pst = p1 A1 + C A3 Pressure at port B: p1 = (p. Ak + F ) AR AR
10 3.0 FLOW CONTROL VALVES Flow control valves serve to influence the speed of movement of users by restricting the oil flow. Stepless speed control is thus possible. Flow control valves can be divided into 4 groups: 1) pressure and viscosity related 2) pressure related, throttle valves but independent of viscosity 3) independent of pressure, but viscosity related 4) independent of pressure and viscosity flow control valves 3.1 Throttle Valves While the flow restriction remains the same, the flow changes according to the pressure drop at the throttle position. Flow Control Valves While the flow restriction remains the same, the flow remains constant, independent of the pressure drop at the flow control valve. Flow at the Throttle Positions The flow at a throttle position is calculated according to the equation: Q A p a p v V dh = flow = throttle sectional area = pressure loss (pressure drop between A and B) = flow coefficient = density = resistance coefficient = throttle range = viscosity = flow speed = hydraulic diameter = 4 A (throttle section) U (flow path)
11 According to the type of throttle, a flow coefficient of can be used for jets and orifices. Throttle Valves The flow of throttle valves is related to the pressure drop at the throttle position, i.e. a larger p results in a larger flow. The equation for the resistance coefficient shows the relationship to the viscosity. The shorter the throttle length I, the less noticeable is a change is viscosity. It should also be noted that the flow increases at the fluid becomes thinner. Whether a valve is dependent on the viscosity or is practically independent, depends on the construction of the throttle position. Throttle valves are used, when: - there is constant working resistance - change in speed is irrelevant or desired with changing load. These throttle valves are related to pressure and viscosity. Oil reaches the throttle position 3 by means of side bores 1 in the housing 2. These are formed between the housing and the adjustable sleeve 4. By turning the sleeve, the ringshaped section at the throttle position can be altered steplessly. There is throttling in both directions (fig.1). If throttling is required in one direction only, an additional check valve is necessary. In throttle direction, fluid reaches the rear side 1 of the valve poppet 2. The poppet of the check valve is pushed on its seat. Throttling procedure is as per type MG (fig 2). In the opposite direction, (right to left) the flow acts on the face surface of the check valve. The poppet is lifted from its seat. Oil flows unthrottled through the valve. At the same time,
12 part of the fluid passes over the ring slot and thus the desired self cleaning process is achieved. Important technical data: Sizes sizes 6 to 102 Flow up to /min Operating pressure up to 315 bar. 3.2 Double Throttle/Check Valve type Z 2 FS: Double throttle/check valves comprise two throttle/check valves arranged symmetrically in one block. symbol. Double Throttle/Check valve Type Z 2 FS 22 They are fitted between the direct operated directional valve and the subplate to influence the speed of a user (main flow limiter). With pilot operated valves, the double throttle/check valve can be used as pilot choke adjustment (pilot flow limiter). It is then fitted between pilot and main valves. (See also the sectional diagram for pilot operated directional valves). With flow from the bottom to the top, pressure acts via bore 1 on the mounting face of the check valve, designed as a throttle pin. The throttle pin is pushed back and no throttling takes place (fig. 4). With flow from the top to the bottom pressure acts via bore 2 on the rear side of the throttle pin. It is pushed against the stop 3 and occupies a throttle position according to the position of adjustment screw 4.
13 Throttling can take place in the supply or drain, depending on the position of the sandwich plate (size 5 and 10) or arrangement of the throttle cartridges (size 16 and 22). Important technical data: Sizes sizes 6, 10, 16, 22 Flow Operating pressure up to 300 1/min up to 315 bar. 3.3 Fine throttle as cartridge unit The fine throttle belongs among flow control valves in group 3 flow is related to pressure and almost independent of viscosity. The viscosity influence is very slight, due to the orifice type throttle position. The sectional diagram (fig. 8) shows a valve with housing. The curved pin 2, setting element 3 with scale and orifice 4 are fitted in the housing. The throttle is adjusted by turning the curved pin, which is joined to the adjustment knob. The flow section is determined by the position of the curved pin, i.e., by the position of curve 5 in front of the orifice window 6. There is a linear or non-linear flow curve over the adjustment angle (300 o ) according to the orifice type. The direction of flow is preferably from A to B. By means of an adjustment screw 7, the orifice opposite one curved pin can be raised or lowered. Adjustment of the setting device is therefore guaranteed. During operation, the orifice with adjustment screws supported on the valve mounting face. A pin is fitted to ensure that the orifice cannot turn in me wrong direction.
14 Important technical data: Size sizes 5 and 10 Flow upto 50 l/min Operating pressure up to 210 bar 3.4 Flow regulating valves In flow regulating valves, the flow is not related to the pressure drop between the valve input and output. This means that the oil flow set remains constant, even with pressure deviations. Flow regulating valves are therefore used when the working speed should remain fixed in spite of different loads at the user. 3.5 Directional Flow Regulating Valves, type 2 FRM In order to understand the function better, it will firstly be described using a circuit diagram. Functional diagram 2 directional flow regulating value. In this case, a regulating spool 2 is controlled before the actual adjustable throttle 1 (fig.10). Flow is from A to B. In each case, the maximum system pressure p 1 builds up in front of the valve. Pressure p3 is behind the valve, according to the working resistance at the user. When the working resistance changes, pressure p3 also changes and thus also the pressure drop from p1 to p3. While the throttle section remains the same, different volumes would therefore flow, if there were no regulating spool.
15 It must be ensured that there is always the same pressure difference p2 p3 at the throttle position, in order to prevent the influence of pressure deviations. This is achieved, using the control spool, also called pressure compensator, as an adjustable throttle element. A spring pushed the spool in opening direction and holds it in neutral position where there is no flow through the valve. If there is flow through the valve, the pressure exert a force on the spool via surfaces A2 and A3. Pressure p2 in front of the throttle position affects the surface A2 by means of a control line. The pressure behind the throttle position affects the surface A3 by means of a control line. The following forces result at the control spool: in opening direction (upwards) F spring + p3. A3 in closing direction (downwards) p2. A2 in control position, i.e. when there is flow through the valve, the forces at the spool are balanced. Conditions for equilibrium: p2. A2 = p3 A3 = F spring/ : A p2 = p3 + F spring A p2 p3 = F spring A The conditions for equilibrium show that the pressure drop p = p2 p3 always results at the throttle position corresponding to the spring force. As only slight spring deflections occur, the spring force can be assumed to be almost constant. If pressure p2 increases, for example due to an increase in pressure at the valve inlet, the regulating spool moves in closing direction. Thus it decreases the quantity of oil flowing to the throttle position until pressure p2 has fallen again and the pressure drop p2 p3 corresponds to spring force : surface area A. The flow therefore remains constant. If, for example, pressure p3 changes (increases or decreases) the spring again moves until the pressure drop p2 p3 = F spring has been reached again. A The excess fluid in front of the valve must be drained by means of the pressure relief valve, as with the throttle described previously.
16 Fig. 11 shows the actual valve. The throttle pin 2 with orifice 3 (as for the fine throttle) and the control spool 4 with spring 5 are fitted in a housing 1. An additional check valve 6 is fitted, to guarantee free flow from B to A. The regulating spool is effective only in flow direction A to B. Pressure in front of the throttle position (p2) is fed by means of bores 7 to the spool surfaces, which lie opposite the spring. Pressure behind the throttle position (p3) affects the spool by means of bore 8, in addition to the spring. To avoid surges, i.e. the regulating spool springs out of neutral position beyond the actual control position, if there is sudden flow through the valve, the spool can be fixed at standstill in a set regulating position by means of a stroke limiter 9.
17 Important technical data: Sizes sizes 5, 10, 16 (also over size 30 with v dependent throttle position) Flow up to 160 l/min Operating pressure upto 315 bar
18 4.0 FLOW CONTROL VALVE FITMENT METHODS Meter in circuit In meter in operation, the flow control valve is placed between the pump and actuator. In this way, it controls the amount of fluid going into the actuator. Pump delivery in excess of the metered amount is diverted to tank over the relief valve. Meter out circuit If the flow control valve is on the outlet side of the cylinder to control the flow coming out, it is called meter out. Regulating the size of the opening controls the flow rate and thus speed of the cylinder. Bleed of Circuit The flow control valve is simply teed off the main line to control cylinder speed. In this case, unlike the meter in or meter out circuit there is not excess flow going over the relief valve and the pump operates at only the pressure that is needed to move the workload on the cylinder.
19 SUMMARY Check valves are used for uni-directional flow. Pilot operated check valves are used as 2-way valve. Flow control valves control the speed of actuator and give fine control independent of load and system temperature. REVIEW OF QUESTIONS Explain the function of a check valve? How a pilot operated check valve works and differs from a check valve? What are the three methods of fitment of flow control valve? What is meant by temperature compensation? To get accurate flow which flow control valve is used? To take care of runaway load which method of flow control valve fitment is recommended. REFERENCE 1. Manuals of reputed Hydraulic product manufacturers.
20
COUNTERBALANCE VALVES
COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load
Chapter 5: Flow Valves
Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free
Example. Fluid Power. Circuits
Example Fluid Power Circuits To Enhance Symbol Reading Skills To Work On Circuit Reading Skills With Answers HI LO Pump Circuit 18 A1 B1 17 16 15 13 Set 14 2,000 PSI PG2 Set 500 PSI 12 11 7 8 10 PG1 9
The Secret of Hydraulic Schematics. BTPHydraulics www.iranfluidpower.com
The Secret of Hydraulic Schematics BTPHydraulics www.iranfluidpower.com www.iranfluidpower.com Table of Contents The Secret to Reading and Interpreting Hydraulic Schematics... 1 Hydraulic System Schematics...
Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage
Safety for Hydraulics Leak free double check valve, pilot operated, series Cartridge type, two stage 8 1 1 General description spring closed, pilot operated, cartridge type poppet valve it holds the load
Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001
Pressure Control Chapter 3 Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001 Introduction Pressure control is a key element in the design of any circuit. Used correctly, it can
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 2 HYDRAULIC AND PNEUMATIC CYLINDERS The material needed for outcome 2 is very extensive
LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS
LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS 1. Define an accumulator and explain its function A hydraulic accumulator is a device that stores the potential energy of an incompressible fluid
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 3 HYDRAULIC AND PNEUMATIC MOTORS The material needed for outcome 2 is very extensive
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 1 HYDRAULIC PUMPS The material needed for outcome 2 is very extensive so there
Flow divider (flow distributor), type TQ
Flow divider (flow distributor), type TQ Pressure p max = 0 bar Flow Q CN max = 00 lpm Share ratio = :. General Task Flow dividers type TQ are self-regulating valves, which largely irrespective of the
Basic Symbols. Lines. Circular. Square. Diamond. Miscellaneous Symbols. -continuous line - flow line. -dashed line - pilot, drain
Airline Hydraulic's Main Page Basic Symbols Lines continuous line flow line dashed line pilot, drain envelope long and short dashes around two or more component symbols. Circular Square Diamond large circle
Hydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 [email protected] www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS
SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents
English translation of German original Technical Information TI-P11 SITEMA PowerStroke Mould Closing Devices series FS drive system for powerful forces on a short stroke hydraulic actuation closing force
GoTo Europe Focused Delivery Program. Product overview industrial and mobile hydraulics
GoTo Europe Focused Delivery Program Product overview industrial and mobile hydraulics 2 GoTo Europe The products I need when I need them In today s global competition every day counts. Fast response times
2-way flow control valve Type 2FRM 6
RE /0.0 Replaces:.0 -way flow control valve Type FRM Nominal size Series X Maximum operating pressure bar ) Maximum flow L/min ) When used in conjunction with a rectifier plate up to 0 bar H//D /97 + H//D
PART 2 FORKLIFT HYDRAULIC SYSTEM
PART 2 FORKLIFT HYDRAULIC SYSTEM Chapter 1 Description and Operation Component Locations & Circuit Layouts 1 Hydraulic Pump 11 Control Valve 14 Valve Section Oil Flows 15 Anti-Cavitation Valve 22 Velocity
Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage
Safety for Hydraulics Leak free check valve, pilot operated, series Cartridge type, two stage prevents a load from falling if a burst occurs in feed pipe hardened seat and poppet prevents creep of hydraulically
Pressure reducing valve, direct operated, Type ZDR 6 D
RE 26 57/2.3 Replaces:.2 Pressure reducing valve, direct operated, ype ZDR 6 D Nominal size 6 Series 4X aximum operating pressure 2 bar aximum flow 5 L/min K 4279/ ype ZDR 6 DP2 4X/ Y Overview of contents
GoTo Europe Focused Delivery Program. Product Overview Hydraulics
GoTo Europe Focused Delivery Program Product Overview Hydraulics 2 GoTo Europe The products I need when I need them In today s global competition every day counts. Fast response times have become an important
Hydraulic Flow Control Valves
Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series
M A N U A L 13-10-05
Documentation The following information sheets illustrate the description below: 12-WW01-4G-E Sectional view of the lance with main dimensions 12-W101-6G-E Sectional view of the head of the lance with
Signature and ISX CM870 Fuel System
Signature and ISX CM870 Fuel System Cummins Ontario Training Center HPI-TP Fuel System Heavy Duty High Pressure Injection - Time Pressure Fuel System The fuel system developed for the Signature and ISX
Steering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min
Steering unit RE 11872/05.06 /10 Type LAGL Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min H7375 Table of contents Contents Page Features 1 Ordering code 2 Function, section 3 Device
Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)
Page 1 of 6 (Home) Symbols / Visit us on: Fluid Power, Automation and Motion Control for all Industries About Us Products Services Catalogs Place an Order Training & Information Contact Us Employee Access
*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type...
Pressure Relief and Regulating Valves
Pressure Relief and Regulating Valves With blocked center directional valves and variable displacement pumps, or open center directional valves and fixed displacement pumps where fast response, low leakage
Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93
Vickers Check Valves Check Valves Inline, right angle, manifold mounted, and pilot operated designs Released 9/93 645 Introduction Vickers inline, right-angle, and manifold mounted check valves are direct
*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type... 5/132...
HYDRAULIC CIRCUIT DESIGN AND ANALYSIS
HYDRAULIC CIRCUI DESIGN AND ANALYSIS A Hydraulic circuit is a group of components such as pumps, actuators, and control valves so arranged that they will perform a useful task. When analyzing or designing
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB
MONO BLOCK DIRECTIONAL CONTROL VALVE TS112TSLB TS TS212TSTSJB P T TS312TSDTSTKJ TS112TSJB FEATURES: O RG PORTS to eliminate leakage. POWER BEYOND CAPABILITY to fit your multi valve circuits. BUILT ANTI-DROP
APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module.
APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS This work covers part of outcome 2 of the standard Edexcel module. The material needed for outcome 2 is very extensive so
MANTA Piston Distributor for Oil and Fluid Grease
MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations
VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................
Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19
Table of Contents Overview 1 Pump Disassembly 2 Control Disassembly / Reassembly 7 Pump Reassembly 13 Adjustment Procedures DR Control 19 Adjustment Procedures DRG Control 20 Adjustment Procedures DFR
Check Valves Valve locator
Check Valves Valve locator Functional Symbol Flow Typical Model Cavity Rating Pressure Page Check valve, direct L/min (USgpm) bar (psi) FPR/4 Inline () 5 (5) - FPR/8 Inline (8) 5 (5) - FPR/ Inline 45 ()
Pressure relief valves Size 6
Pressure relief valves Size 6 direct controlled Interface to DIN 24 340 and ISO 6264 PN [p max. ] = bar 750400.06.0.06 Description (standard units) Design The pressure relief valves of Type D B C 6 are
Chapter 6: Check Valves
Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Shuttle valves SSR -2 Check valves, direct operated RK / R CS SPZE SPV
Troubleshooting Guide for Jacks Down LED Lights
Troubleshooting Guide for Jacks Down LED Lights Equalizer Systems Auto-Level systems manufactured after 2005 feature a pressure switch system that monitors the retracted state of leveling jacks and any
Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)
Oildyne Hydraulic Power Units Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) 11 Power Unit Features We are pleased to introduce our new power units. The power units let you put more power where
Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.
DAN-LIQ-TG-44-rev0208 February 2008 Daniel Liquid Control Valves Technical Guide www.daniel.com Daniel Measurement and Control Theory, Principle of Operation and Applications This brochure has been prepared
Control block EDD Modular Directional Valve
Control block EDD Modular Directional Valve 2 Control block EDD Modular Directional Valve Bosch Rexroth Oil Control S.p.A. introduces this innovatory Directional Control Valve size 8 which allows to create
2/2 and 3/2 Way Size 6 Seat Valves
2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08
SIMPLIFIED VALVE CIRCUIT GUIDE
NA-09 FLOW CONTROL METERED- FREE FLOW UT OUT CYLDER TENDED SOLENOID NO. A Guide to Understanding Pneumatic Directional Control Valves SIMPLIFIED CIRCUIT GUIDE 0 0 0 0 Compressed Air Valves Directional
Chapter 11 SERVO VALVES. Fluid Power Circuits and Controls, John S.Cundiff, 2001
Chapter 11 SERVO VALVES Fluid Power Circuits and Controls, John S.Cundiff, 2001 Servo valves were developed to facilitate the adjustment of fluid flow based on the changes in the load motion. 1 Typical
Hydraulic Trouble Shooting
Hydraulic Trouble Shooting Hydraulic systems can be very simple, such as a hand pump pumping up a small hydraulic jack, or very complex, with several pumps, complex valving, accumulators, and many cylinders
Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM
Introduction Manapak valves provide a variety of check, flow control, pressure relief and pressure reducing functions in a compact NFPA D03, D05 and D08 sandwich style valve. The NFPA D03 valve body conforms
3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow
1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control
Quiz On Information Learned From Chapter 1
Quiz On Information Learned From Chapter 1 1. Most hydraulic circuits are designed by: A. mechanical engineers. B. fluid power engineers. C. fluid power distributor salesmen. 2. Atmospheric pressure at
SITEMA PowerStroke. Technical Information TI-P12. 1 Function. 2 Applications. Mould Closing Devices series FSKP. Contents
SITEMA PowerStroke FSP ocking, actuating and releasing by pneumatic pressure English translation of German original Technical Information TI-P1 SITEMA PowerStroke Mould Closing Devices series FSP drive
Line rupture protection valves type LB
Line rupture protection valves type LB Pressure p max Flow rate Q A max = 500 bar = 4... 160 lpm Screw-in versions Type LB...C In-line versions Type LB...G Type LB...F 1. General Line rupture protection
Ergo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
Pressure Relief Valves SPV, SPVF
Pressure Relief Valves SPV, SPVF Construction of the Pressure Relief Valves SPV, SPVF Symbol Description The direct spring, sliding piston Pressure Relief Valve SPV/SPVF is intended for inline mounting
Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.
Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power
AIR-AIR PRESSURE MULTIPLIER (BOOSTER)
AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally
SIMPLIFIED VALVE CIRCUIT GUIDE
SIMPLIFIED CIRCUIT GUIDE A GUIDE TO UNDERSTANDG PNEUMATIC DIRECTIONAL CONTROL S SOLENOID NO. 0 OUT 0 FLOW CONTROL METERED- FREE FLOW 0 0 OUT CYLDER TENDED Z-00 Compressed Air Valves Directional control
V47 Series Temperature Actuated Modulating Water Valves
V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate
3/2- and 2/2-way cartridge valve type BVE
3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type
(A5) Brakes Sample Questions and Answers
(A5) Brakes Sample Questions and Answers Answers to these questions are found beginning on page 4 of this document 1. Two technicians are discussing a problem where the brake pedal travels too far before
Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40
Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane
Chapter 19 - Common Rail High Pressure Fuel Injection Systems
Chapter 19 - Common Rail High Pressure Fuel Injection Systems Diesel Engine Technology For Automotive Technicians Understanding & Servicing Contemporary Clean Diesel Technology What is Common Rail? Common
Fuel System Description. Stromberg 175 CD-2 SE And SU-HS 6 Carburettors
Fuel System Description Stromberg 175 CD-2 SE And SU-HS 6 Carburettors The B 20 A engine is fitted with a horizontal carburettor of typo Stromberg 175 CD-2 SE, see Fig. 60. The B 20 B engine In the l20
Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US
Catalog HY15-352/US Contents Control SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI NEED VALVES J2A2... C8-2... Needle Valve, Cartridge Type...45/12... 42/6... 5-6 NVH81... C8-2... Needle
2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow
2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description
Hydraulic Troubleshooting PRESENTED BY
Hydraulic Troubleshooting PRESENTED BY NORMAN KRONOWITZ Introduction Welcome to the CMA/Flodyne/Hydradyne s Hydraulic Troubleshooting presentation. We will introduce many aspects of troubleshooting hydraulic
PRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
LOADER DIRECTIONAL CONTROL VALVE LV LV22RFSTKLB SHOWN T
LOADER DIRECTIONAL CONTROL VALVE LV LV22RFSTKLB SHOWN T LV22RFSTKLB A2 B2 A1 B1 P LV22RFSTKABW FEATURES: O RING PORTS to eliminate leakage. FOURTH POSITION REGEN allows cylinder to rapidly extend. POWER
Control blocks for two-hand start ZSB
Key features Function This pneumatic control block for twohand start ZSB is used where a manually started operation, such as the triggering of compressed air cylinders, would otherwise involve danger for
MONO BLOCK DIRECTIONAL CONTROL VALVE TS
SHIPPING: 2332 S 25TH STREET (ZIP 6815) MAILING: P.O. BOX #669 OMAHA, NE 6816 PHONE: (42) 344-4434 FAX: (42) 341-5419 HTTP://WWW.BRAND-HYD.COM MONO BLOCK DIRECTIONAL CONTROL VALVE TS TS312TSDTSTKJB TS2
Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
PVH131/141 Variable Displacement Piston Pump - 11 Design
Service Data Vickers Piston Pumps PVH131/141 Variable Displacement Piston Pump - 11 Design Revised 05/01/97 M-2209-S Maximum Adjustable Stop S Option 913341 Locknut Torque 25-50 N.m. (18-37 lb. ft.) Torque
Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.
TXV - Presentation pumps with Load Sensing control variable displacement piston pumps ADVANTAGES pumps are variable displacement with pressure-flow control called Load Sensing. They self-regulate to give
ACCUMULATOR INSTALLATION
7001-7 ACCUMULATOR INSTALLATION BRAKE ACCUMULATORS I 308L93 Rae 7-59710 Issued 6-93 Printed in U.S.A 7001-8 Removal ACCUMULATOR VALVE 1. Park the machine on a level surface and lower the. loader bucket
Hydraulics Trouble Shooting Guide. TS-Guide_R.doc
Hydraulics Trouble Shooting Guide TS-Guide_R.doc Table of Contents Condensed Table... 1 Valves... 3 Cylinders... 3 Boosters... 4 Fluid Motors... 5 Vane Pumps... 6 Radial Piston Pumps... 9 Hydraulic Systems...
Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits
Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot
Chapter 7 Hydraulic System Troubleshooting
Chapter 7 Hydraulic System Troubleshooting General The following troubleshooting information is provided as a general guide to identify, locate and correct problems that may be experienced with the hydraulic
D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10
D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 OVERVIEW D660 Section Page MOOG SERVO-PROPORTIONAL CONTROL VALVES Overview 2 3 Technical Data 4 5 Electronics
Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.
Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical
Radial piston pumps type R and RG
Radial piston pumps type R and RG Operating pressure p max = 700 bar Delivery flow Q max = 91.2 lpm (at 1450 rpm) Geometric displacement V g max = 64.2 cm 3 /rev. 1. General Motor pumps and hydraulic power
Load-sensing control block in mono and sandwich plate design
Load-sensing control block in mono and sandwich plate design RE 64276/08.2010 Replaces: 08.2008 1/64 Type M4-12 Nominal size 12 Unit series 2X Nominal pressure 350 bar (pump side) Nominal pressure 420
Open center control block in monoblock design MO-40
Open center control block in monoblock design MO-40 RE 64370 Edition: 02.2015 Replaces: 02.1985 Size 40 Series 1X Maximum working pressure on pump side 350 bar on consumer side 420 bar Maximum flow 680
Electro-Pneumatic Bus Door Control Mechanism
Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with
Laddomat 21-60 Charging unit
Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the
Variable Displacement Pump AA10VSO
Variable Displacement Pump AA10VSO Series 31, Industrial Model, for Open Circuits Axial piston, swashplate design Brueninghaus Hydromatik Sizes 28...140 Nominal pressure 4000 psi Peak pressure 5100 psi
Description of functions
Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the
Series PVP Variable Volume Piston Pumps
Series PVP Variable Volume Piston Pumps Catalog HY28-2662-CD/US Revised June, 212 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference
PUMP AND MOTOR DIVISION
INSTALLATION MANUAL SERIES P2 and P3 MOBILE PISTON PUMP 1 Check model code / compare with your paper work Nameplate of the pump Ordering / Sales Acknowledgement 2 Check rotation of the pump Clockwise rotation
Product catalogue, pipe and sewer cleaning systems
Product catalogue, pipe and sewer cleaning systems Nozzles Rotorjet trolley Hose reels Cleaning devices www.hammelmann.com Contents (Navigation via Bookmarks) Rotorjet trolley Rotary joints, spray pipes
Rexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
Buy Karcher Parts Online: www.pressureparts.com. Need Technical Help? Call: 1-800-999-2245 email Requests to: sales@pressureparts.
Karcher Model: K 620-M * ( 59556440 ) - Parts Section:1.1 TOP PART Page 1 of 18 1 50346460 1 STRAP 2 63031250 6 SCREW 3 50670230 1 COVER 4 63031940 2 SELF-TAPPING SCREW 5 50309650 1 COVER 6 50635710 1
Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves
Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves CRANE Energy Flow Solutions TM Donald H. Johnson Crane Energy Flow Solutions 1 Crane Co. Resolution Made By Richard Teller
Cooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.
Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.
Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4
MASTER CYLINDER. Section 2. Master Cylinder. Tandem Master Cylinder. Master Cylinder