Residual Chlorine Simulation in Water Distribution Network

Size: px
Start display at page:

Download "Residual Chlorine Simulation in Water Distribution Network"

Transcription

1 Residual Chlorine Simulation in Water Distribution Network T.Kondo 1, T.Fuchigami 2 1 Water Distribution Department of Osaka City Waterworks Bureau, Nankou-Kita, Suminoe-ku, Osaka-city, Osaka, JAPAN,( t-kondou@suido.city.osaka.jp) 2 Water Examination Laboratory of Osaka City Waterworks Bureau, Kunijima, Higashiyodogawa-ku, Osaka-city, Osaka, JAPAN Annotation Osaka City is working to maintain free residual chlorine concentrations as low as possible but within the range of the required legal standard, at the end of the water distribution network in order to improve the efficiency of disinfectant chlorine injection and reduce chlorine odor in tap water. We have developed a simulation method as a means for achieving these goals, to directly estimate free residual chlorine concentrations at arbitrary points in the water distribution network in Osaka City using the first- and zero-order rate equations for the reduction in free residual chlorine concentration. We have also conducted two case studies to compare the measured values with simulated ones. Consequently, a good reproducibility was confirmed. We intend to utilize our simulation method not only to control free residual chlorine concentration properly in distribution network but also to detect the points where free residual chlorine concentration becomes too low level because water keeps staying, which leads to identify the effective pipe renovation work from the aspect of the reduction of free residual chlorine decay. Keywords Free residual chlorine, water distribution network, simulation of the reduction rate of free residual chlorine concentration, EPANET2, rate coeffi cient for the reduction rat e of free residual chlorine concentration 1. INTRODUCTION The control of free residual chlorine concentrations in the water distribution network is an essential task to ensure the safety of tap water against infectious microorganisms. The Japanese Waterworks Law stipulates that free residual chlorine in tap water is kept at a concentration of 0.1 mg/l or greater, however, the results of a customer survey of inhabitants of Osaka City showed their desire to reduce free residual chlorine concentrations as much as possible for reduction of tastes and odors cause by chlorine while maintaining the safety of the tap water. Free residual chlorine concentrations vary between areas surrounding a water purification plant and water distribution plants, where chlorine is put into the water and areas at the end of the water distribution network due to different flow times. At present, to maintain free residual chlorine concentrations at the end of the water distribution network at 0.1 mg/l or greater, the Osaka City Waterworks Bureau (OCWB) aims to restrict the upper concentration to 0.4 mg/l. However, to supply water with high quality in terms of odor and taste and to reduce the cost of chlorine injection, it is effective to reduce the differences in free residual chlorine concentrations in Osaka City and maintain them as low as possible, therefore, the OCWB is installing additional chlorine injection facility in secondary water distribution plants. To control chlorine injection, the OCWB sets the volume of chlorine injection at the output of the water purification plant and in some of water distribution plants installed with facilities for additional chlorine injection, in order to maintain free residual chlorine concentrations at the end of the water distribution network at 0.1 mg/l or greater. The OCWB is monitoring the quality of water

2 in distribution pipes at 38 sites in Osaka City using water quality sensors in order to prevent free residual chlorine concentrations from falling below the lower limit. Furthermore, if a simulation method to accurately estimate a free residual chlorine concentration at an arbitrary point in the water distribution network in addition to the above measures is available, it is allowed to control free residual chlorine concentrations in broader areas in a precise manner, i.e., optimal chlorine injection including additional injection and appropriate measures for local reduction in free residual chlorine concentrations of some areas due to the status of the water distribution network (water retention and chlorine consumption on the inner surface of aging pipes). The OCWB started to develop a simulation method in 2007 and conducted a case study including a comparison between simulated and measured concentrations in two water distribution areas in Osaka City. Consequently, a good reproducibility of simulation results was confirmed. The process is described below. 2. METHODS 2.1. Development of a distribution network model The analysis software used was EPANET2 [1], a program that models water flow including mixing and separating of water flows in water distribution pipeline network and provides time series data analysis, integrated with a geographic information system. A distribution network model was developed using the geolocation and pipe line profile and demand data obtained from the pipeline information system that was organized using GIS by Osaka City, as well as data on ground height in digital national land information provided by the Geographical Survey Institute Rate equation for the reduction in free residual chlorine concentrations The simulation method for concentrations of free residual chlorine in a water distribution network accurately estimates the flow time at an arbitrary point in the network using time series analysis, considering changes in water demand and mix and separate flows at nodes, and directly estimates free residual chlorine concentrations using the first- and zero-order rate equations for the reduction in free residual chlorine concentrations. Considering a previous study [2] and report [3] of the OCWB, the following equation is used as a rate equation for the reduction in free residual chlorine concentrations in water distribution pipes. dc dt 4 ( kb C kw) (1) d where, C: free residual chlorine concentration (mg/l) k b: bulk decay rate coefficient for the reduction in free residual chlorine concentration (day -1 ) k w : rate coefficient for the reduction in free residual chlorine concentration derived from the inner surface condition of a water distribution pipe (mg/m 2 /day) d: diameter of a pipe (m) 2.3. Conditions in time series analysis for water distribution networks Hydraulic calculation was performed using the Hazen-Williams equation, and the roughness constant for pipe walls in the equation (C) was specified as 90 in all cases. As for the effluent volume at the output of each water distribution plant and free residual chlorine concentrations at that point, which are the start points of the analysis, the data for 24 hours from the data sequentially monitored and measured was given as the default condition. The simulation method for free residual chlorine concentration was assessed by comparison between measured free residual chlorine concentrations in water samples collected from a fire

3

4 Validation in the water distribution area of Nagai Water Distribution Plant (Case study 2) In other water distribution areas in Osaka City except for those of Sakishima Water Distribution Plant, various pipes with differences in the type of inner lining and the year of installation had been laid. Therefore, to extend the application of this simulation method, the second case study was conducted in a water distribution area with plural type of pipes in order to assess the reproducibility of this simulation method considering differences in pipe types. Based on the results of preliminary studies, the rate coefficient for the reduction in free residual chlorine concentration by distribution route was estimated considering the year of installation and the type of inner lining of distribution pipes. Subsequently, after substituting the estimated rate coefficient into the rate equation for the reduction in free residual chlorine concentration, the effect of the differences in pipe type was evaluated. Overview of the water distribution area of Nagai Water Distribution Plant and distribution pipes laid down in the area Nagai Water Distribution Plant is located in the southeastern region and distributes water by pump pressure to surrounding areas which have approximately 125,000 households. This area is isolated from surrounding distribution areas by shutting valves installed at the boundaries between distribution areas. The maximum distribution volume in this area is approximately 110,000 m 3 /day. As for the water-supply system, water is distributed from Niwakubo Water Purification Plant to Tatsumi Water Distribution Plant, the primary plant, using a transmission pump. Subsequently, water pooled in a reservoir in Tatsumi Plant is distributed to Nagai Water Distribution Plant, the River Yodo Niwakubo Purification Plant Chlorine injection Tatsumi Distribution Plant Nagai Distribution Plant secondary plant, using a water-distribution pump, while some of water is distributed to households (see Figure 3). Chlorine in water distributed from Nagai Water Distribution Plant is injected in two stages, i.e., in the final process of water purification at Niwakubo Water Purification Plant, and subsequently at the entry of Nagai Water Distribution Plant as an additional injection. However, at present, chlorine injection in the output of Niwakubo Water Purification Plant is substantial in order to maintain free residual chlorine concentrations at 0.1 mg/l or greater, because, in Niwakubo disutribution area, secondary distribution plants except Nagai Water Distribution Plant are not installed with facilities for additional chlorine injection and the free residual chlorine concentration of water supplied from Nagai Water Distribution Plant is sequentially monitored using two water-quality telemeters installed in this distribution area. The total length of pipes in the water distribution area of Nagai Water Distribution Plant is 330 km, and pipes with a small-diameter of 300 mm or less accounts for approximately 89%. The pipes used comprised non-lined cast-iron pipes, cast-iron pipes renovated with liquid epoxy resin-lining, and mortar-lined ductile iron pipes. Mortar-lined ductile iron pipes that were laid down in 1997 or before accounts for approximately 84% of the total pipe length(see Figure 4). P P Tatsumi supply area Additional chlorine injection Nagai suppl y area Figure 3 Water distribution system for Nagai Water Distribution area P

5 The inner surface type of distribution pipes Mortar-lined (after 1998) Mortar-lined (before 1997) Epoxy resin-coated (renovated pipes) Non-lined Nagai Water Distribution Plant 3. 8% 6.2% 0. 5% 5.1% 12.2% Total length of pipes 330km 88.7% Pipes by diameter 300<D 300<D < D Ratio of distribution pipes by diameter Total length of pipes 330km 83. 5% Pipes by inner surface type Liquid epoxy res in-coated Mortar-lined (1998- ) Mortar-lined (-1997) Non-lined Ratio of distribution pipes by inner-surface type Figure 4 Overview of pipe network in Nagai Water Distribution area Simulation of pipe network in Nagai Water Distribution area The k b value in the above Equation (1) was fixed separately [5], similarly to Case Study 1, using the following equation (Equation (2)), an approximate equation obtained from the laboratory results with water treated in a water purification plant in Osaka City, by substituting water temperature on the measurement day. k b exp(0.0742T ) (2) where, T: water temperature ( C) In comparison between measured and estimated concentrations, the correlation coefficient between them was 0.81 (n=21) and the profile of reduction in free residual chlorine concentrations was approximately reproduced. Consequently, the application of this simulation method is considered to be acceptable. In addition, the water demand of each household was set at a nodal point nearby the pipe network model using the annual data of water consumption by water supply meter for approximately 125,000 households. Since common houses and apartments have been built in most of the distribution area of Nagai Water Distribution Plant, an hourly change in water demand patterns over the whole area of Nagai Water Distribution Plant corresponds to an hourly change in patterns of total water distribution amounts at Nagai Plant (see Figure 5).

6 Nagai Wat er Distribut ion Plant Overview of the distribution network model Number of pipes: 2546 Number of joints: 3847 Hydraulic calculation: Hazen-Williams Equation C value: 90 Water distribution volume (m 3 /h) :00 3:00 5:00 Average water temperature (effusion site ): 29.0 C Da ily total volume of wa ter distribution 106, 000 m 3 (data a s of Se ptember 13, 2007) 7:00 Tota l volume of wate r distribution from Nagai Water Distribution Plant (m 3 /h) Initial residual chlorine concentration (mg/l) (effusion site of Nagai Water Distribution Plant) 9:00 11: 00 13: 00 Time Volume of water distribution and initial residual chlorine concentration in Nagai Water Distribution Plant Figure 5 Overview of the distribution network model in Nagai Water Distribution area Based on the results of time series analysis for Nagai water distribution network in advance, candidate sites with a low concentration of free residual chlorine were selected, and subsequently, free residual chlorine concentrations were measured at 21 fire hydrants that were located at these sites or the distribution routes which lead to the these sites(see Figure 6). Simulation results using k w values based on analysis by pipe type was compared with that based on analysis with a specified constant as k w value, in order to validate the effect of simulation using k w values by pipe type. 15: 00 17: 00 19: 00 21: 00 23: Residual chlorine concentration (mg/l) The inner surf ace type of distribution pipes D Yamasaka N=3 Mortar -lined (after 1998) Mortar -lined (before 1997) Epoxy resin-coated ( renovated pipes) Non-lined Nagai Water Distribution Plant H Minamisumiyoshi E Nagaihigashi G Terugaokayata C Nagayoshirokutan N=2 N=2 N=3 N=1 N=3 N=2 A Uriwarihigashi N=2 N=3 B Nagayoshi kawanabe F Yamanouchi Figure 6 Site map of fire hydrants for free residual chlorine concentration measurement

7 Measurement survey of rate coefficients for the reduction in free residual chlorine concentration derived from inner surface status by pipe type(k w ). The k w values were measured by pipe type in a measurement survey. Of distribution pipes (diameter: 100 to 300 mm) in the distribution area, pipes in which water can be pooled intentionally by shutting valves without affecting customers (e.g. pipes which are a parts of network loop and have no service connection) were selected and after measuring the initial concentration of free residual chlorine, the time to reach the concentration of 0.10 mg/l or less, a free residual chlorine concentration at that point and water temperature in a water sample were measured. First, the k b value was estimated using the above Equation (2), and subsequently substituted into Equation (1) with other measured data. The k w values are shown in Table 1. Table 1 Measurement results of k w by pipe type Pipe type kw value Rati o of pi pes in water distribution area (mg/m 2 /day) (%) High-quality cast iron pipe / Non-lined pipe 705.6(n=1) 0.5% High-quality cast iron pipe / Liquid epoxy-lined pipe 9.6(n=3) 3.8% Ductile iron pipe (before 1997) / Mortar-lined pipe 11.5(n=6) 83. 5% Ductile iron pipe (after 1998) / Mortar-lined pipe 4.3(n=4) 12. 2% 3. RESULTS AND DISCUSSION Figure 7 shows the comparison between measured and estimated concentrations when different k w values by pipe type were substituted. On the other hand, Figure 8 demonstrates the comparison when k w value was constant (used a k w value of mortar-lined (old) pipe, which was most of the total length of distribution pipes). The correlation coefficient of the former was while that of the latter was Since both of them were high, the profile of reduction in free residual chlorine concentrations was almost reproduced. When k w values classified by pipe were used, the reproducibility of simulation outcomes increased compared with that of simulations using a constant k w value. In particular, reproducibility was improved in the end area of the southeastern region, in which most pipes laid were relatively new. In this simulation, accuracy was improved by approximately 10% in the standard deviation of errors between measured and estimated concentrations. Therefore, in this water distribution area, where the majority of pipes was mortar-lined ductile iron pipe and laid down before 1997, the accuracy of simulation outcomes was considered to be sufficiently acceptable in practice when the water flow time in pipe networks was accurately reproduced, even if the k w value of the major pipe type was used for all of the pipes Theoretical value Figu re 8 Comparison between measured and estimatedconcentrations when kw was constant However, the k w value of non-lined pipe was markedly faster than that of other type pipes, therefore, in an area distributed through many non-lined pipes, simulation with k w values classified Actual measurement Actual measurement R= Theoretical value Residual chlorine concentr atio n (mg/l) Correlation coefficient Figure 7 Comparison between measured and estimated concentrationswhen kw was classified by pipe type Resid ual chlorine concentration (mg/l) Correlation coefficient R=0.79

8 by pipe type should be conducted. In the k w measurement survey, water sampling was carried out at 12 points due to the limitation of available pipe routes. Since the k w value of non-lined pipes was markedly faster than that of other type pipes, when long-term water pooling in non-lined pipes is predicted by the simulation outcomes, the relevant pipes should be replaced earlier and regular monitoring and control systems for free residual chlorine concentration in seasons with high water temperature should be established. 4. CONCLUIONS The results of the two case studies validated a good reproducibility in the simulation outcomes of free residual chlorine concentration, and therefore, this simulation method developed by the OCWB is expected to be applied under the following conditions: to estimate target values of chlorine injection optimal for each water purification plant and distribution plant when separate injection of chlorine is installed. to predict an area where free residual chlorine concentration can be reduced by water pooling in distribution pipes and plan a reasonable renovation of pipe networks for water quality control, considering the reduction properties of free residual chlorine concentration from the standpoint for the reduction of pipe diameter and the priority of renovation, and to examine whether water pooling occurs in distribution network due to changes in water flow associated with long-term water suspension of a part of the network due to renovation construction work. Future tasks are to improve the accuracy of simulation outcomes and expand versatility in order to apply the measures to all of Osaka City. To improve the accuracy of simulation outcomes, it is important to evaluate the properties of pipes such as C values in a distribution network model, and improve the reproducibility of water flow conditions including the use of the measured values of water pressure and flow amounts in distribution pipes, discharge pressure and flow amounts in water purification and distribution plants. In addition, to expand the application of the simulation method to a practical level, sensitivity analysis should be conducted on the effects of changes in variables including water temperature, k b, k w, and C values on simulation outcomes. It is also important to judge to what extent accuracy should be improved in the future. To expand application of the simulation method to all of Osaka City, a distribution network model including border areas where water flow turns between adjacent distribution blocks should be developed and organized as a model with water flow patterns between these blocks. Considering the above issues, we intend to improve the accuracy of this simulation method and expand its versatility. REFERENCES [1]Rossman, L. A. (2000). EPANET2 Users Manual.EPA-600/R-00/057. USEPA National Risk Management Research Laboratory, Cincinnati, USA [2]FUCHIGAMI, Tomohiro and TERASHIMA, Katsuhiko. (June 2005). Development of control method for residual chlorine concentrations considering chlorine consumption on the inner surface of distribution pipes. Journal of the Japan Water Works Association, vol.74, No.6 (No.849), pp [3]John, J.V.et al. (1997). Kinetics of chlorine decay. JOURNAL AWWA, Vol.89, pp [4] NAGATANI,Toru. et al. (2006). Residual chlorine concentration simulation in water distribution network. The 7th International Symposium on Water Supply Technology [5]FUCHIGAMI, Tomohiro and TERASHIMA, Katsuhiko. (2003). Behavior of residual chlorine in water aft er advanced puri fication treatment in distribution pipe process in Osaka City and its control. Journal of the Japan Water Works Association, vol.72, No.6 (No.825), pp.12-24

Residual Chlorine Decay Simulation in Water Distribution System

Residual Chlorine Decay Simulation in Water Distribution System The 7 th International Symposium on Water Supply Technology, Yokohama 2006, November 22-24, 2008, Yokohama, Japan Residual Chlorine Decay Simulation in Water Distribution System Toru Nagatani (Osaka Municipal

More information

Water Supply. Simulation of Water Distribution Networks. Mohammad N. Almasri. Optimal Design of Water Distribution Networks Mohammad N.

Water Supply. Simulation of Water Distribution Networks. Mohammad N. Almasri. Optimal Design of Water Distribution Networks Mohammad N. Water Supply Simulation of Water Distribution Networks The Use of EPANET Mohammad N. Almasri 1 Introduction This presentation focuses on two issues: The simulation of water distribution networks (WDNs)

More information

Optimizing the hydraulic designing of pressurized irrigation network on the lands of village Era by using the computerized model WaterGems

Optimizing the hydraulic designing of pressurized irrigation network on the lands of village Era by using the computerized model WaterGems Optimizing the hydraulic designing of pressurized irrigation network on the lands of village Era by using the computerized model WaterGems Ali Ghadami Firouzabadi 1 and Majid Arabfard 2 1. Ali Ghadami

More information

Evaluation of Fire Protection Capacity in Disasters Based on Disaster Resilience Curve

Evaluation of Fire Protection Capacity in Disasters Based on Disaster Resilience Curve Evaluation of Fire Protection Capacity in Disasters Based on Disaster Resilience Curve N. Hirayama, T. Yamada, M. Wada, S. Itoh, and C. A. Davis ABSTRACT After the 2011 Tohoku disaster, water supply utilities

More information

Tokyo Waterworks supports the capital of Tokyo

Tokyo Waterworks supports the capital of Tokyo Tokyo Waterworks supports the capital of Tokyo Tokyo, the Japanese capital, is the largest city in Japan with a population of about 13.16 million, which is about 10% of the country s entire population

More information

Design Criteria & Service Goals

Design Criteria & Service Goals 4.1 Design Life of Improvements The design life of a water system component is sometimes referred to as its useful life or service life. The selection of a design life is a matter of judgment based on

More information

4 Water supply description

4 Water supply description 4 Water supply description A description of the drinking-water system is equally applicable to large utilities with piped distribution systems, piped and non-piped community supplies, including handpumps

More information

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS Shiwei William Guan, Ph.D. Vice President, R&D and International Business Madison Chemical Industries Inc. 490

More information

Real-time Monitoring Platform to Improve the Drinking Water Network Efficiency

Real-time Monitoring Platform to Improve the Drinking Water Network Efficiency Real-time Monitoring Platform to Improve the Drinking Water Network Efficiency SUMMARY Recent advances in real-time water sensing technology have enabled new opportunities for improved assessment and management

More information

Special Linings for unusual service conditions. Please contact ACIPCO.

Special Linings for unusual service conditions. Please contact ACIPCO. Linings Linings Along with technical and metallurgical advancement in piping materials, research on lining requirements for pipe and fittings has resulted in the development of linings to meet many different

More information

INNOVATION AND COST EFFECTIVE APPROACH TO POTABLE WATER PIPE REPLACEMENT STRATEGICALLY FOCUSED ON DISTRIBUTION SYSTEM WATER QUALITY IMPROVEMENT By

INNOVATION AND COST EFFECTIVE APPROACH TO POTABLE WATER PIPE REPLACEMENT STRATEGICALLY FOCUSED ON DISTRIBUTION SYSTEM WATER QUALITY IMPROVEMENT By INNOVATION AND COST EFFECTIVE APPROACH TO POTABLE WATER PIPE REPLACEMENT STRATEGICALLY FOCUSED ON DISTRIBUTION SYSTEM WATER QUALITY IMPROVEMENT By ABSTRACT Migdalia Hernandez, City of Sanford P.O. Box

More information

WATER LEAKAGE AND DETECTION IN MUNICIPAL WATER DISTRIBUTION NETWORKS. N. Merzi (1) and T. Özkan (2)

WATER LEAKAGE AND DETECTION IN MUNICIPAL WATER DISTRIBUTION NETWORKS. N. Merzi (1) and T. Özkan (2) Water Supply and Drainage for Buildings, 29th Int. Symposium, Turkey WATER LEAKAGE AND DETECTION IN MUNICIPAL WATER DISTRIBUTION NETWORKS N. Merzi (1) and T. Özkan (2) (1)merzi@metu.edu.tr (2)tozkan@metu.edu.tr

More information

Power consumption (kw)

Power consumption (kw) OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components

More information

Practice Tests Answer Keys

Practice Tests Answer Keys Practice Tests Answer Keys COURSE OUTLINE: Module # Name Practice Test included Module 1: Basic Math Refresher Module 2: Fractions, Decimals and Percents Module 3: Measurement Conversions Module 4: Linear,

More information

Bromate Formation and its Control in Advanced Water Treatment System 高 度 浄 水 処 理 における 臭 素 酸 の 生 成 と 制 御

Bromate Formation and its Control in Advanced Water Treatment System 高 度 浄 水 処 理 における 臭 素 酸 の 生 成 と 制 御 Bromate Formation and its Control in Advanced Water Treatment System 高 度 浄 水 処 理 における 臭 素 酸 の 生 成 と 制 御 Tohru Miyagaki, Bureau of Waterworks, Tokyo Metropolitan Government, Japan 東 京 都 水 道 局 宮 垣 融 Bromate

More information

SEISMIC DAMAGE ESTIMATION PROCEDURE FOR WATER SUPPLY PIPELINES

SEISMIC DAMAGE ESTIMATION PROCEDURE FOR WATER SUPPLY PIPELINES SEISMIC DAMAGE ESTIMATION PROCEDURE FOR WATER SUPPLY PIPELINES Ryoji ISOYAMA 1, Eisuke ISHIDA 2, Kiyoji YUNE 3 And Toru SHIROZU 4 SUMMARY This paper presents a practical procedure for estimating damage

More information

Water hammering in fire fighting installation

Water hammering in fire fighting installation Water hammering in fire fighting installation Forward One of major problems raised in the fire fighting network installed at Pioneer company for pharmaceutical industry /Sulaymania was the high water hammering

More information

Leak detection in virtual DMA combining machine learning network monitoring and model based analysis

Leak detection in virtual DMA combining machine learning network monitoring and model based analysis Leak detection in virtual DMA combining machine learning network monitoring and model based analysis Author Dr. Gangl Gerald*, Raúl Navas ** * Dr. Gerald Gangl, Kriegsbergstraße 31, 70327 Stuttgart, Germany,

More information

2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS

2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS 2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS Water system improvements proposed for inclusion into Western s service area shall be designed in accordance with all appropriate AWWA standards, include

More information

HM Manager Overview. Applies to the spatial version of Netbase. Integrates Netbase with Water Distribution Modelling Software

HM Manager Overview. Applies to the spatial version of Netbase. Integrates Netbase with Water Distribution Modelling Software Model Build INTRODUCTION HM Manager Overview Applies to the spatial version of Netbase Provides the complete modelling solution: Fully integrated with EPAnet & Piccolo Integrates Netbase with Water Distribution

More information

STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS

STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS PART 1 GENERAL 1.1 DESCRIPTION A. Section includes requirements for cleaning and lining existing cast iron and ductile iron water mains

More information

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS INTRODUCTION 1. There are no general EU regulations and standards for outdoor swimming pool heating. Local regulations in the member countries are covering most

More information

Water Distribution Solution for More Efficient Operation of Water Supply

Water Distribution Solution for More Efficient Operation of Water Supply Hitachi Review Vol. 64 (215), No. 9 564 Featured Articles Water Distribution Solution for More Efficient Operation of Water Supply Shinsuke Takahashi, Ph.D. Shingo Adachi Takeshi Takemoto Minoru Umeki

More information

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation Introduction The importance of keeping cooling tower water in proper chemical

More information

PERFORMANCE EVALUATION OF A DRINKING WATER DISTRIBUTION SYSTEM USING HYDRAULIC SIMULATION SOFTWARE FOR THE CITY OF OILTON, OKLAHOMA

PERFORMANCE EVALUATION OF A DRINKING WATER DISTRIBUTION SYSTEM USING HYDRAULIC SIMULATION SOFTWARE FOR THE CITY OF OILTON, OKLAHOMA PERFORMANCE EVALUATION OF A DRINKING WATER DISTRIBUTION SYSTEM USING HYDRAULIC SIMULATION SOFTWARE FOR THE CITY OF OILTON, OKLAHOMA By NEHA MANGESH BHADBHADE Bachelor of Science in Instrumentation and

More information

SECTION 15041 DISINFECTION OF PIPE AND WATER STORAGE FACILITIES

SECTION 15041 DISINFECTION OF PIPE AND WATER STORAGE FACILITIES SECTION 15041 DISINFECTION OF PIPE AND WATER STORAGE FACILITIES PART 1 GENERAL 1.01 DESCRIPTION This section describes requirements for disinfection by chlorination of potable water mains, services, pipe

More information

Water System Disinfection

Water System Disinfection Water System Disinfection Document Number Revision 1 Approved By Ric Morris All 6/2/04 Active Divisions/Departments FEMC Raytheon Polar Services Company HARD COPY NOT CONTROLLED-CONTROLLED COPY AVAILABLE

More information

Dynamic Modeling Of An Ozone Disinfection Facility

Dynamic Modeling Of An Ozone Disinfection Facility Dynamic Modeling Of An Ozone Disinfection Facility Michael Etheridge Black & Veatch 8400 Ward Parkway Kansas City, MO 64114 Presented to the Fourteenth Ozone World Congress August 25 th, 1999 ABSTRACT

More information

Investigations of a Long-Distance 1000 MW Heat Transport System with APROS Simulation Software

Investigations of a Long-Distance 1000 MW Heat Transport System with APROS Simulation Software th International Conference on Structural Mechanics in Reactor Technology (SMiRT ) Espoo, Finland, August 9-4, 9 SMiRT -Division 3, Paper 56 Investigations of a Long-Distance MW Heat Transport System with

More information

ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. II - Transportation of Hydrogen by Pipeline - Kunihiro Takahashi TRANSPORTATION OF HYDROGEN BY PIPELINE

ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. II - Transportation of Hydrogen by Pipeline - Kunihiro Takahashi TRANSPORTATION OF HYDROGEN BY PIPELINE TRANSPORTATION OF HYDROGEN BY PIPELINE Kunihiro Takahashi Director, Center for Supply Control and Disaster Management, Tokyo Gas Co. Ltd., Tokyo, Japan Keywords: pipeline transportation of gaseous hydrogen,

More information

Overview of Drinking Water Quality Management in Japan 日 本 の 水 道 の 歴 史 について

Overview of Drinking Water Quality Management in Japan 日 本 の 水 道 の 歴 史 について Overview of Drinking Water Quality Management in Japan 日 本 の 水 道 の 歴 史 について Yasuo Yanagibashi, MHLW, Japan 厚 生 労 働 省 柳 橋 泰 生 Overview of Drinking Water Quality Management in Japan Yasuo YANAGIBASHI Director,

More information

Water Management in Helsinki. Water supply. Mikael Sillfors

Water Management in Helsinki. Water supply. Mikael Sillfors Water Management in Helsinki Mikael Sillfors Helsinki is located on the northern shore of the Gulf of Finland. The main water systems in the area are the Gulf of Finland and River Vantaa, which runs through

More information

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids Dr. J. M. Meyers Dr. D. G. Fletcher Dr. Y. Dubief 1. Introduction Last lab you investigated flow loss in a pipe due to the roughness

More information

Appendix A: Acceptable pipe and fitting materials

Appendix A: Acceptable pipe and fitting materials Watercare Services Limited Water and Code of Practice Content from the NZS 4404:2010 Land development and subdivision infrastructure has been reproduced for use in the Infrastructure Design s Manual for

More information

1 DESCRIPTION OF THE APPLIANCE

1 DESCRIPTION OF THE APPLIANCE 1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers

More information

Pressure drop in pipes...

Pressure drop in pipes... Pressure drop in pipes... PRESSURE DROP CALCULATIONS Pressure drop or head loss, occurs in all piping systems because of elevation changes, turbulence caused by abrupt changes in direction, and friction

More information

Module 7: Hydraulic Design of Sewers and Storm Water Drains. Lecture 7 : Hydraulic Design of Sewers and Storm Water Drains

Module 7: Hydraulic Design of Sewers and Storm Water Drains. Lecture 7 : Hydraulic Design of Sewers and Storm Water Drains 1 P age Module 7: Hydraulic Design of Sewers and Storm Water Drains Lecture 7 : Hydraulic Design of Sewers and Storm Water Drains 2 P age 7.1 General Consideration Generally, sewers are laid at steeper

More information

Users Guide. By Dr. Don J. Wood Dr. Srinivasa Lingireddy. Featuring the Surge Wizard

Users Guide. By Dr. Don J. Wood Dr. Srinivasa Lingireddy. Featuring the Surge Wizard Users Guide By Dr. Don J. Wood Dr. Srinivasa Lingireddy Featuring the Surge Wizard Copyrighted KYPIPE LLC 2010 1 EPASurge Users Guide Overview EPASurge is a powerful transient analysis program designed

More information

A Design of DC/DC Converter of Photovoltaic Generation System for Streetcars

A Design of DC/DC Converter of Photovoltaic Generation System for Streetcars Journal of International Council on Electrical Engineering Vol. 3, No. 2, pp.164~168, 2013 http://dx.doi.org/10.5370/jicee.2013.3.2.164 A Design of DC/DC Converter of Photovoltaic Generation System for

More information

ElastoFlake & ElastoTec

ElastoFlake & ElastoTec ElastoFlake & ElastoTec Relining Group 02 Revolutionally injection casting ElastoFlake, a new material from the Relining Group, is a polymer plastic mass intended for injection casting, which was developed

More information

A methodology for monitoring and leakage reduction in water distribution systems

A methodology for monitoring and leakage reduction in water distribution systems Water Utility Journal 2: 23-33, 2011. 2011 E.W. Publications A methodology for monitoring and leakage reduction in water distribution systems M. Nicolini University of Udine Department of Chemistry, Physics

More information

Repair and Disinfection of Water Mains Water Protection Program fact sheet

Repair and Disinfection of Water Mains Water Protection Program fact sheet Repair and Disinfection of Water Mains Water Protection Program fact sheet 9/2012 Every year waterborne disease outbreaks occur in the United States as a result of public water distribution system defi

More information

Zhao et al. 2.2 Experimental Results in Winter Season The analysis given below was based on the data collected from Nov. 2003 to Mar. 15, 2004.

Zhao et al. 2.2 Experimental Results in Winter Season The analysis given below was based on the data collected from Nov. 2003 to Mar. 15, 2004. Proceedings World Geothermal Congress 2005 Antalya, Turkey, 24-29 April 2005 A Case Study of Ground Source Heat Pump System in China Jun Zhao, Chuanshan Dai, Xinguo Li, Qiang Zhu and Lixin Li College of

More information

MAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES

MAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES MAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES John van Rijn INDEVELOPMENT MAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES Any part of this publication may be

More information

WATER QUALITY AND STANDARDS Vol. I -Management of Water Supplies After A Disaster - Yasumoto Magara, Hiroshi Yano

WATER QUALITY AND STANDARDS Vol. I -Management of Water Supplies After A Disaster - Yasumoto Magara, Hiroshi Yano MANAGEMENT OF WATER SUPPLIES AFTER A DISASTER Yasumoto Magara Professor of Engineering, Hokkaido University, Sapporo, Japan Hiroshi Director, Kobe Municipal Water Works Bureau, Kobe, Japan Keywords: Earthquake

More information

TOWN OF MEREDITH Administrative Services 41 Main Street, Meredith, New Hampshire 03253-5861 Telephone (603) 279-4538 Fax (603) 279-1042

TOWN OF MEREDITH Administrative Services 41 Main Street, Meredith, New Hampshire 03253-5861 Telephone (603) 279-4538 Fax (603) 279-1042 TOWN OF MEREDITH Administrative Services 41 Main Street, Meredith, New Hampshire 03253-5861 Telephone (603) 279-4538 Fax (603) 279-1042 REQUEST FOR PROPOSAL 2010 HYDRAULIC MODEL I. General Information:

More information

Murcia. Capital and most populous city of the Region de Murcia. Seventh largest city in Spain.

Murcia. Capital and most populous city of the Region de Murcia. Seventh largest city in Spain. SMART WATER Murcia. Capital and most populous city of the Region de Murcia. Seventh largest city in Spain. Population of the city: 450.000 inhabitants. (about one third of the total population of the Region).

More information

Determination of Thermal Conductivity of Coarse and Fine Sand Soils

Determination of Thermal Conductivity of Coarse and Fine Sand Soils Proceedings World Geothermal Congress Bali, Indonesia, - April Determination of Thermal Conductivity of Coarse and Fine Sand Soils Indra Noer Hamdhan 1 and Barry G. Clarke 2 1 Bandung National of Institute

More information

Water Quality Contingency Planning Standard EPB 540B

Water Quality Contingency Planning Standard EPB 540B Water Quality Contingency Planning Standard EPB 540B November 15, 2012 Water Quality Contingency Planning Standard The Water Quality Contingency Plan Standard is provided to aid waterworks owners and operators

More information

Prevention of Water Leakage in Tokyo

Prevention of Water Leakage in Tokyo Prevention of Water Leakage in Tokyo 2014 Bureau of Waterworks, Tokyo Metropolitan Government Prevention of Water Leakage in Tokyo 2014 Bureau of Waterworks, Tokyo Metropolitan Government Contents Page

More information

Amir Bashirzadeh Tabrizi, Nassir Gifani. TOOSSAB Consulting Engineers Company e-mail: bashirzadeh@hotmail.com, nssrgifani@gmail.com.

Amir Bashirzadeh Tabrizi, Nassir Gifani. TOOSSAB Consulting Engineers Company e-mail: bashirzadeh@hotmail.com, nssrgifani@gmail.com. International Renewable Energy Congress November 5-7, 2010 Sousse, Tunisia Economical and Environmental Effects of Pressure Reducer Valve Substituting by Small Hydro Power-Plants in Gravity Water Transmission

More information

RENEW. A Water Main Cleaning and Lining Program Designed to Improve Water Quality and Service

RENEW. A Water Main Cleaning and Lining Program Designed to Improve Water Quality and Service Investing in Our Infrastructure RENEW A Water Main Cleaning and Lining Program Designed to Improve Water Quality and Service 1500 Ronson Road P.O. Box 1500 Iselin, New Jersey 08830-3020 renew Hotline 800-549-3802

More information

Stenner Pump Chlorinator Installation & Start Up Guide

Stenner Pump Chlorinator Installation & Start Up Guide Clean Water Made Easy www.cleanwaterstore.com Stenner Pump Chlorinator Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

STANDARD OPERATING PROCEDURES FOR ALL WATERMAIN DISTRIBUTION REPAIR & INSTALLATION

STANDARD OPERATING PROCEDURES FOR ALL WATERMAIN DISTRIBUTION REPAIR & INSTALLATION Page 1 of 14 O&P 1.1 October 2005 J. Boc No.:F11 15/06/10 J. Boc STANDARD OPERATING PROCEDURES FOR ALL WATERMAIN DISTRIBUTION REPAIR & INSTALLATION 1.0 Purpose The purpose of this procedure is to ensure

More information

TALLINN WATER TREATMENT AND SEWERAGE Tuuli Myllymaa

TALLINN WATER TREATMENT AND SEWERAGE Tuuli Myllymaa TALLINN WATER TREATMENT AND SEWERAGE Tuuli Myllymaa Tallinn is the capital of Estonia. It has approximately 450,000 inhabitants and the town area is about 150 km 2. Tallinn Water Ltd., owned by the City

More information

EVALUATION OF GEOTHERMAL ENERGY AS HEAT SOURCE OF DISTRICT HEATING SYSTEMS IN TIANJIN, CHINA

EVALUATION OF GEOTHERMAL ENERGY AS HEAT SOURCE OF DISTRICT HEATING SYSTEMS IN TIANJIN, CHINA EVALUATION OF GEOTHERMAL ENERGY AS HEAT SOURCE OF DISTRICT HEATING SYSTEMS IN TIANJIN, CHINA Jingyu Zhang, Xiaoti Jiang, Jun Zhou, and Jiangxiong Song Tianjin University, North China Municipal Engineering

More information

Energy Recovery System for Excavators Meng (Rachel) Wang, Chad Larish Eaton Corporation

Energy Recovery System for Excavators Meng (Rachel) Wang, Chad Larish Eaton Corporation Energy Recovery System for Excavators Meng (Rachel) Wang, Chad Larish Eaton Corporation Abstract Increasing fuel costs have become a significant portion of the operating expenses for owners and fleet managers

More information

Calibration and Uncertainties of Pipe Roughness Height

Calibration and Uncertainties of Pipe Roughness Height 9 th IWA/IAHR Conerence on Urban Drainage Modelling Calibration and Uncertainties o Pipe Roughness Height Kailin Yang, Yongxin Guo, Xinlei Guo,Hui Fu and Tao Wang China Institute o Water Resources and

More information

Acoustic Leak Detection. Gander Newfoundland 2006

Acoustic Leak Detection. Gander Newfoundland 2006 Acoustic Leak Detection Gander Newfoundland 2006 Overview Background on Leakage and leak Detection Water Loss Management Fundamentals of Correlation Leakage The unintentional escape or loss of water from

More information

Other Innovative Mueller Products

Other Innovative Mueller Products Our Products Mueller has built its reputation on producing innovative water distribution products of superior quality a reputation that is literally on the line every day throughout the world. Mueller

More information

Pipe Flow-Friction Factor Calculations with Excel

Pipe Flow-Friction Factor Calculations with Excel Pipe Flow-Friction Factor Calculations with Excel Course No: C03-022 Credit: 3 PDH Harlan H. Bengtson, PhD, P.E. Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980

More information

CHAPTER 11 STORM DRAINAGE

CHAPTER 11 STORM DRAINAGE CHAPTER STORM DRAINAGE SECTION PC 0 GENERAL 0. Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. Storm water discharge shall be

More information

Unified Costing Model User s Guide

Unified Costing Model User s Guide Unified Costing Model User s Guide FINAL VERSION 1.0 May 2013 Prepared for: Texas Water Development Board Prepared by: The Unified Costing Model (UCM) for Regional Water Planning is not intended to be

More information

Hydraulic losses in pipes

Hydraulic losses in pipes Hydraulic losses in pipes Henryk Kudela Contents 1 Viscous flows in pipes 1 1.1 Moody Chart.................................... 2 1.2 Types of Fluid Flow Problems........................... 5 1.3 Minor

More information

The 3rd Busan Global Water Forum 2015. Multi-Parameter Water Quality Monitoring System. Aqua2000. 3 of Sep 2015 Kyung-Yup Hwang

The 3rd Busan Global Water Forum 2015. Multi-Parameter Water Quality Monitoring System. Aqua2000. 3 of Sep 2015 Kyung-Yup Hwang The 3rd Busan Global Water Forum 2015 Multi-Parameter Water Quality Monitoring System Aqua2000 3 of Sep 2015 Kyung-Yup Hwang CONTENTS 1. Company Profile 2. Tap Water Management Issues 3. Overview of Aqua2000

More information

CHAPTER 2 HYDRAULICS OF SEWERS

CHAPTER 2 HYDRAULICS OF SEWERS CHAPTER 2 HYDRAULICS OF SEWERS SANITARY SEWERS The hydraulic design procedure for sewers requires: 1. Determination of Sewer System Type 2. Determination of Design Flow 3. Selection of Pipe Size 4. Determination

More information

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

1.3.2 Method of construction and restoration of existing water service connections. This shall include: 1.0 GENERAL 1.1 DESCRIPTION: This specification shall cover the rehabilitation of existing water lines using the GRUNDOCRACK PIPE BURSTING SYSTEM. Pipe bursting is a system by which the pneumatic bursting

More information

Recent outbreaks of pinhole leaks nationally are a significant issue. Figure 1.1 shows the

Recent outbreaks of pinhole leaks nationally are a significant issue. Figure 1.1 shows the CHAPTER 1 - INTRODUCTION 1. 1 Motivation Recent outbreaks of pinhole leaks nationally are a significant issue. Figure 1.1 shows the national distribution of pinhole leaks based on the data gathered by

More information

ON-LINE MONITORING SYSTEM OF WATER LEAKAGE DETECTION IN PIPE NETWORKS WITH ARTIFICIAL INTELLIGENCE

ON-LINE MONITORING SYSTEM OF WATER LEAKAGE DETECTION IN PIPE NETWORKS WITH ARTIFICIAL INTELLIGENCE ON-LINE MONITORING SYSTEM OF WATER LEAKAGE DETECTION IN PIPE NETWORKS WITH ARTIFICIAL INTELLIGENCE A.Ejah Umraeni Salam 1, Muh.Tola 1, Mary Selintung 2 and Farouk Maricar 2 1 Department of Electrical Engineering,

More information

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015 Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015 Presentation Outline Mechanical Overview Chillers and Pumps Pipework and Ancillaries In Row Cooling Units

More information

PREDICTIVE AND OPERATIONAL ANALYTICS, WHAT IS IT REALLY ALL ABOUT?

PREDICTIVE AND OPERATIONAL ANALYTICS, WHAT IS IT REALLY ALL ABOUT? PREDICTIVE AND OPERATIONAL ANALYTICS, WHAT IS IT REALLY ALL ABOUT? Derek Vogelsang 1, Alana Duncker 1, Steve McMichael 2 1. MWH Global, Adelaide, SA 2. South Australia Water Corporation, Adelaide, SA ABSTRACT

More information

Inspection and Testing of Water-Based Systems

Inspection and Testing of Water-Based Systems Inspection and Testing of Water-Based Systems Standard Model/Computer-Based Testing Level III Content Outline The candidate for NICET certification at Level III in the Inspection and Testing of Water-Based

More information

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Record MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Abandoned Gravity Private Combined Gravity Private Foul Gravity Private Surface Water Gravity Public Combined Gravity Public Foul Gravity Public

More information

Rehabilitation of Wastewater Treatment Plant of Sakhnin City in Israel by Using Advanced Technologies

Rehabilitation of Wastewater Treatment Plant of Sakhnin City in Israel by Using Advanced Technologies Rehabilitation of Wastewater Treatment Plant of Sakhnin City in Israel by Using Advanced Technologies Yasar Avsar 1, Hussein Tarabeah 2, Shlomo Kimchie 3, Izzet Ozturk 4, Hadi Naamneh 2 1 Yildiz Technical

More information

Water Volume Calculation in Hydronic Heating & Cooling Systems

Water Volume Calculation in Hydronic Heating & Cooling Systems Water Volume Calculation in Hydronic Heating & Cooling Systems Preface There are several methods which can be used to calculate the volume of water in a hydronic heating or cooling systems. However, these

More information

Designer-Oriented Electric Field Analysis System for Power Cable Accessories

Designer-Oriented Electric Field Analysis System for Power Cable Accessories ANALYSIS TECHNOLOGY er-oriented Electric Field Analysis System for Power Cable Accessories Yuuichi NAKAMURA*, Tomohiro KEISHI and Miki USUI Sumitomo Electric has worked on electric for more than 30 years.

More information

Drinking Water and Wastewater Operator Certificate Programs

Drinking Water and Wastewater Operator Certificate Programs Drinking Water and Wastewater Operator Certificate Programs Drinking Water and Wastewater Operator employment opportunities should be excellent for qualified workers For Information or to Enroll: Washington

More information

PLANT LOCATION AND LAYOUT

PLANT LOCATION AND LAYOUT PLANT LOCATION AND LAYOUT The Location Of The Plant Can Have A Crucial Effect On The Profitability Of A Project, And The Scope For Future Expansion. Many Factors Must Be Considered When Selecting A Suitable

More information

The Pipelines Regulations, 2000

The Pipelines Regulations, 2000 PIPELINES, 2000 P-12.1 REG 1 1 The Pipelines Regulations, 2000 being Chapter P-12.1 Reg 1 (effective April 1, 2000) as amended by the Statutes of Saskatchewan, 2014, c.21. NOTE: This consolidation is not

More information

Performance Estimation of Water Thermal Energy Storage Tank by Using Simplified Simulation

Performance Estimation of Water Thermal Energy Storage Tank by Using Simplified Simulation Performance Estimation of Water Thermal Energy Storage Tank by Using Simplified Simulation M. Kubota, K. Sagara, T. Yamanaka, H. Kotani Division of Global Architecture, Graduate School of Engineering,

More information

On-Line Computer Models. Off-Line Computer Models. Spatial Visualization of Network Components. Supervisory Control and Data Acquisition (SCADA)

On-Line Computer Models. Off-Line Computer Models. Spatial Visualization of Network Components. Supervisory Control and Data Acquisition (SCADA) PROJECT DESCRIPTION The United States Department of Homeland Security (DHS) has established 18 sectors of infrastructure and resource areas that comprise a network of critical physical, cyber, and human

More information

Modeling, GIS Software Optimizes Water Main Cleaning By Paul F. Boulos

Modeling, GIS Software Optimizes Water Main Cleaning By Paul F. Boulos Modeling, GIS Software Optimizes Water Main Cleaning By Paul F. Boulos Close by Paul F. Boulos Maintaining the hydraulic and water quality integrity of drinking water distribution systems is a key concern

More information

Small-Micro Hydro Facilitation & Innovative Technologies in Japan

Small-Micro Hydro Facilitation & Innovative Technologies in Japan 1 HYDROVISION2006 Oregon Convention Center, Portland, Oregon USA July 31 August 5, 2006 Innovative Small and Medium Hydro Technologies Workshop By IEA Small Hydro Annex-2 2 & NRCan - CETC Small-Micro Hydro

More information

December 2003 EPB 241B. Some sections are completed, some are partially complete and some are left blank.

December 2003 EPB 241B. Some sections are completed, some are partially complete and some are left blank. Note: As of October 1, 2012 The Water Security Agency and Saskatchewan Ministry of Environment share responsibility and authority for the administration of The Environmental Management and Protection Act,

More information

Asset Management and Condition Monitoring

Asset Management and Condition Monitoring Asset Management and Condition Monitoring SIMATIC PCS 7 Monitoring Block PumpMon Function Block for cost-effective Monitoring and Diagnostics of Centrifugal Pumps August 2008 Especially in chemical industries,

More information

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS GAP.14.1.2.2 A Publication of Global Asset Protection Services LLC WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS INTRODUCTION A hydrant or other large-volume flow test is necessary for proper water

More information

TG 105 ALLOWABLE PIPE SIZE, CLASS AND MATERIALS FOR WATER MAINS TECHNICAL GUIDELINE. Manager Asset Management SOUTH AUSTRALIAN WATER CORPORATION

TG 105 ALLOWABLE PIPE SIZE, CLASS AND MATERIALS FOR WATER MAINS TECHNICAL GUIDELINE. Manager Asset Management SOUTH AUSTRALIAN WATER CORPORATION TG 105 SOUTH AUSTRALIAN WATER CORPORATION TECHNICAL GUIDELINE ALLOWABLE PIPE SIZE, CLASS AND MATERIALS FOR WATER MAINS Issued by: Manager Asset Management Issue Date: SA WATER 2007 This document is copyright

More information

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm: Page 1 of 6 Section 1. PURPOSE This policy is an Engineering checklist of the Local Review Program for sanitary sewer improvement projects by the Bedford Regional Water Authority ( Authority ). Section

More information

Underground Storage Tanks

Underground Storage Tanks Underground Storage Tanks An Informational and Guidance Document for the University Community. Please contact Yale Environmental Health and Safety for latest Regulatory Requirements. A typical UST installation

More information

Experiences Using Water Network Analysis Modeling for Leak Localization

Experiences Using Water Network Analysis Modeling for Leak Localization Experiences Using Water Network Analysis Modeling for Leak Localization S. Sethaputra*, S. Limanond*, Z. Y. Wu**, P. Thungkanapak***, K. Areekul*** * Technology Service and Consulting 1656 Co., Ltd. Bangkok

More information

Chlorine Residual Testing Fact Sheet

Chlorine Residual Testing Fact Sheet Chlorine Residual Testing Fact Sheet The presence of free chlorine residual in drinking water indicates that: 1) a sufficient amount of chlorine was added to the water to inactivate most of the bacteria

More information

Advanced Natural Gas Storage (ANGAS) Project and Verification Tests of Experimental Lined Rock Cavern in Japan

Advanced Natural Gas Storage (ANGAS) Project and Verification Tests of Experimental Lined Rock Cavern in Japan Advanced Natural Gas Storage (ANGAS) Project and Verification Tests of Experimental Lined Rock Cavern in Japan Toru Komatsubara THE JAPAN GAS ASSOCIATION Taku Watanabe TOKYO GAS CO.,LTD. Satoshi Murase

More information

SUSPENSION AND STEERING OVERVIEW

SUSPENSION AND STEERING OVERVIEW SUSPENSION SUSPENSION AND STEERING OVERVIEW The S40/V50 has a wide track and a long wheelbase for its relative size and weight. This gives the car stable and predictable driving characteristics. It also

More information

Rehabilitation Scenarios for Sustainable Water Mains. University, Montreal, Quebec, Canada, PH (514) 848-2424 ext. 8779; FAX (514) 848-7965; email:

Rehabilitation Scenarios for Sustainable Water Mains. University, Montreal, Quebec, Canada, PH (514) 848-2424 ext. 8779; FAX (514) 848-7965; email: Rehabilitation Scenarios for Sustainable Water Mains Khaled Shahata 1 ; Tarek Zayed 2 ; and Saad Al-Jibouri 3 1 Graduate Student, Department of Building, Civil, and Environmental Engineering, Concordia

More information

DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING

DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING Toshiharu Kagawa 1, Yukako Saisu 2, Riki Nishimura 3 and Chongho Youn 4 ABSTRACT In this paper, we developed a new laminar flow

More information

REGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

REGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 99 REGISTRATION EXAMINATION, JUNE 009 PLUMBING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE

More information

Evaluation of Organic Compound Removal by Advanced Water Treatment System

Evaluation of Organic Compound Removal by Advanced Water Treatment System Evaluation of Organic Compound Removal by Advanced Water Treatment System D.Masuzaki*, S.Imanaka*, H, Hayashi* *Water Examination Laboratory, Osaka Municipal Waterworks Bureau, 1-3-14, Kunijima, Higashiyodogawa-ku,

More information

CGC s Hybrid System Loop Control

CGC s Hybrid System Loop Control verview The CGC Group Hybrid Heat Pump System does NT operate with the same fluid loop temperatures as a conventional reversing Water Source Heat Pump system. The CGC system differs from a WSHP system

More information

Minor losses include head losses through/past hydrants, couplers, valves,

Minor losses include head losses through/past hydrants, couplers, valves, Lecture 10 Minor Losses & Pressure Requirements I. Minor Losses Minor (or fitting, or local ) hydraulic losses along pipes can often be estimated as a function of the velocity head of the water within

More information