1 . Leeds Carnegie, student accommodation.

2 Contents Section overview Introduction 0 Separating floors 0-05 Internal floors 06 Separating walls loadbearing 07 Separating walls non-loadbearing 08 Internal partitions loadbearing 09 Internal partitions non-loadbearing 0 - External walls Ceiling membranes Construction details Technical Advice Centre tel:

3 Separating wall - pages Internal partition - pages 09 - Separating floor - pages bgtechnical.enquiries@bpb.com 0

4 Introduction Timber frame construction is well established in the UK, and British Gypsum products are extensively used to form the internal elements. Internal partitions and walls can be used in both new-build and refurbishment. Gyproc plasterboards are used to line the timber stud framing, whilst Isover insulation products can be used to improve sound, fire and thermal insulation even further. External linings are based on a structural timber frame and can be lined with Gyproc plasterboards to form the internal lining. Floors and ceilings combine Gyproc plasterboard ceilings with Gyproc flooring solutions to provide the required impact and airborne sound insulation, as well as the necessary fire resistance. Again, Isover insulation can be used to improve the thermal and sound insulation. Roofs can be underlined with Gyproc plasterboards and Isover insulation for good sound and thermal insulation. Cavity barriers comprising British Gypsum Gyproc / Glasroc and Isover products can be specified for concealed spaces in the structure or fabric of the building in order to satisfy national Building Regulations requirements for providing suitable cavity barriers and fire-stopping. Whilst timber frame is a form of lightweight construction it has good inherent strength with a lower overall dead weight than masonry, and it is not uncommon for buildings to be built up to seven storeys with timber. Leeds Carnegie, student accommodation. 0 Technical Advice Centre tel:

5 Separating floors Typical platform floor construction (comprising walking surface of 8mm t&g wood board flooring, spot-bonded with Gyproc Sealant at 00mm centres to a substrate of Gyproc Plank laid on 5mm Isover Sound Deadening Floor Slab, laid on a minimum of mm wood-based sheet sub-deck nailed to the joists) over 95mm x mm timber joists at 600mm centres. 00mm Isover Acoustic Partition Roll (APR 00) between the joists. Linings as in table. Typical platform floor construction (comprising walking surface of 8mm t&g wood board flooring, spot-bonded with Gyproc Sealant at 00mm centres to a substrate of Gyproc Plank laid on 5mm Isover Sound Deadening Floor Slab, laid on a minimum of mm wood-based sheet sub-deck nailed to the joists) over minimum 95mm x 8mm timber joists at 600mm centres. Gypframe RB Resilient Bars fixed to underside of joists at 50mm centres and at perimeter with ceiling. Linings as in table fixed into the bars only. 00mm Isover Spacesaver Ready-Cut in the cavity. Table. Compartment / separating solid timber joist and sub-joist floors solutions to satisfy the requirements of 76: Part : 987 Detail Nominal Board Available Ceiling Maximum Sound insulation System floor type with ACTIVair lining loadbearing R w (R w + C tr ) L nw reference depth technology thickness ratio Airborne impact mm mm mm 0 Gyproc Plank % 6 (50) 56 C Gyproc Sounloc 0 Gyproc Sounloc x 5 00% 66 (55) 8 C06050 These systems have an ACTIVair board option available for formaldehyde control to improve indoor air quality. Alternatively, all systems can be skim finished with Thistle PureFinish which contains ACTIVair technology. Refer to the indoor air quality section in Background & theory. NB Separating floors require both a suitable isolating floor and a suitable isolating ceiling. NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. NB Where boards are fixed direct to timber joists, Drywall Timber Screws should be used as opposed to nail-fixing to minimise the risk of fixing defects occurring. bgtechnical.enquiries@bpb.com 0

6 CasoLine MF ceiling suspended beneath 95 x 5mm timber joists at 600mm centres with t&g chipboard flooring using Gypframe Acoustic Hangers to give 77mm cavity. 80mm Isover Modular Roll in cavity. Linings as in table. Floating floor laid over joists. CasoLine MF ceiling suspended beneath 95mm x 5mm timber joists at 600mm centres to give 77mm cavity. 80mm Isover Modular Roll in cavity. Linings as in table. Floating floor laid over 8 x 95mm (minimum) timber joists at 600mm centres. Gypframe RB Resilient Bars fixed to underside of joists at 50mm centres with ceiling linings (see table) fixed into the bars only. 00mm Isover Spacesaver Ready-Cut in the cavity. Table. Compartment / separating solid timber joist floor, CasoLine MF solutions to satisfy the requirements of 76: Part : 987 Detail Board Available Ceiling Floor Sound insulation System type with ACTIVair lining depth R w (R w + C tr ) L nw reference technology thickness mm Airborne impact mm 0 minutes fire resistance Gyproc Sounloc x (55) 5 C060 Gyproc Sounloc x (5) 50 C060 Gyproc FireLine x (5) 55 C060 Gyproc Sounloc x (5) 50 C0605 Gyproc Sounloc x (5) 55 C0600 Comprising walking surface of 8mm t&g chipboard flooring, spot-bonded with Gyproc Sealant at 00mm centres to a substrate of Gyproc Plank laid on 5mm Isover Sound Deadening Floor Slabs (Rigid Grade, laid on a minimum of mm wood-based sheet sub-deck nailed to the joists). Normal fixing centres for Gypframe MF5 Ceiling Section and Gypframe MF7 Primary Support Channel (50mm and 00mm respectively). Suspension method is Gypframe MF8 Strap Hangers or Gypframe GA Steel Angle unless otherwise stated. These systems have an ACTIVair board option available for formaldehyde control to improve indoor air quality. Alternatively, all systems can be skim finished with Thistle PureFinish which contains ACTIVair technology. Refer to the indoor air quality section in Background & theory. NB The ceiling cavity is the distance from the underside of the walking surface to the back of the plasterboard ceiling lining. 0 Technical Advice Centre tel:

7 GypFloor SILT comprising Gyproc Plank on Gypframe SIF Floor Channel located over timber joists (minimum 95mm deep at 50mm / 600mm centres). Walking surface of chipboard or softwood flooring (mm minimum). 00mm Isover Spacesaver Ready-Cut in the cavity. Gypframe RB Resilient Bars fixed at 50mm centres. Ceiling linings as in table. CasoLine MF ceiling suspended beneath GypFloor SILT using Gypframe Acoustic Hangers to give 77mm cavity. 00mm Isover Spacesaver Ready-Cut laid on ceiling boards. Ceiling linings as in table. Table. GypFloor SILT timber floor fire resistance solutions to satisfy the requirements of 76: Part : 987 and Table - GypFloor SILT 65-: 000 Detail Ceiling Available Lining Floor Sound insulation System lining with ACTIVair thickness depth R w (R w + C tr ) L nw reference technology mm mm Airborne impact Gyproc Plank + Gyproc Sounloc (5) 55 C000 Gyproc Sounloc x (55) 5 C0606 These systems have an ACTIVair board option available for formaldehyde control to improve indoor air quality. Alternatively, all systems can be skim finished with Thistle PureFinish which contains ACTIVair technology. Refer to the indoor air quality section in Background & theory. bgtechnical.enquiries@bpb.com 05

8 Internal floors mm t&g (softwood or chipboard) floor boarding over minimum 95mm x 8mm timber joists at 600mm centres. Noggings and linings as in table. mm t&g (softwood or chipboard) floor boarding over minimum 95mm x 8mm timber joists at 600mm centres. Noggings and linings as in table. Table. Compartment / separating solid timber joist and sub-joist floors solutions to satisfy the requirements of 76: Part : 987 and 65-: 000 Detail Nominal Board Ceiling Noggings Maximum Sound insulation System floor type lining required loadbearing R w L nw reference depth thickness ratio Airborne impact mm mm 0 minutes fire resistance Gyproc WallBoard x 5 Yes 00% 0 C0609 Gyproc FireLine x.5 Yes 00% 0 76 C Technical Advice Centre tel:

9 Separating walls loadbearing Two separate timber frames spaced 50mm apart, consisting of 89mm x 8mm timber studs at 600mm centres with noggings. Two layers of board each side. 00mm Isover Spacesaver Ready-Cut between the studs on one side. Linings as in table. Two separate timber frames spaced 50mm apart, consisting of 89mm x 8mm timber studs at 600mm centres with noggings. Two layers of board each side. 5mm Isover Acoustic Partition Roll (APR 00) between the studs on one side. Linings as in table. 5 Two separate timber frames spaced a minimum of 50mm apart (0mm minimum between inner facings of wall linings). Two layers of board each side. 65mm Isover Acoustic Partition Roll (APR 00) or 90mm Isover Frame Batt between the studs in each timber frame. Linings as in table. Two separate timber frames, each with a 9mm minimum thick sheathing board, spaced a minimum of 50mm apart (0mm minimum between inner facings of wall linings). Two layers of board each side. 65mm Isover Acoustic Partition Roll (APR 00) or 90mm Isover Frame Batt between the studs in each timber frame. Linings as in table. Table.5 89mm timber stud compartment / sound insulating walls solutions to satisfy the requirements of 76: Part : 987 and 65-: 999 (where applicable) Detail Partition Board Available Lining Minimum Maximum Sound System thickness type with ACTIVair thickness stud size load ratio insulation reference mm technology mm mm R w (R w + C tr ) Two separate timber frames spaced 50mm apart, consisting of 89mm x 8mm timber studs at 600mm centres with noggings. Two layers of board each side. 00mm Isover Acoustic Partition Roll (APR 00) between the studs on one side. Linings as in table. 90 Gyproc Sounloc x 5 89 x 8 80% 6 (5) A Gyproc Plank + Gyproc WallBoard x 8 80% 6 (5) A Gyproc Sounloc or x 5 89 x 8 80% RD RD Gyproc Plank + Gyproc WallBoard Gyproc Sounloc or x 5 89 x 8 80% RD RD Gyproc Plank + Gyproc WallBoard Gyproc Plank + Gyproc FireLine x 8 60% 6 (5) A0600 Subject to timber size. RD = Approved Robust Detail Specification E-WT-. For more information visit RD = Approved Robust Detail Specification E-WT-. For more information visit These systems have an ACTIVair board option available for formaldehyde control to improve indoor air quality. Alternatively, all systems can be skim finished with Thistle PureFinish which contains ACTIVair technology. Refer to the indoor air quality section in Background & theory. NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. bgtechnical.enquiries@bpb.com 07

10 Separating walls non-loadbearing Two separate timber frames spaced 50mm apart, consisting of 89mm x 8mm timber studs at 600mm centres with noggings. Two layers of board each side. 00mm Isover Spacesaver Ready-Cut between the studs on one side. Linings as in table. Two separate timber frames spaced 50mm apart, consisting of 89mm x 8mm timber studs at 600mm centres with noggings. Two layers of board each side. 5mm Isover Acoustic Partition Roll (APR 00) between the studs on one side. Linings as in table. Two layers of board each side of 75mm x 8mm timber studs at 600mm centres with Gypframe RB Resilient Bars fixed horizontally to one side at 600mm centres. 50mm Isover Acoustic Partition Roll (APR 00) in the cavity. Linings as in table. Two layers of board each side of 75mm x 8mm timber studs at 600mm centres with Gypframe RB Resilient Bars fixed horizontally to both sides at 600mm centres. 50mm Isover Acoustic Partition Roll (APR 00) in the cavity. Linings as in table. Table.6 75mm and 89mm timber stud walls solutions to satisfy the requirements of 76: Part : 987 and 6-: 999 (where applicable) Detail Partition Board Available Lining Minimum Sound System thickness type with ACTIVair thickness stud size insulation reference mm technology mm mm R w (R w + C tr ) 90 Gyproc Sounloc x 5 89 x 8 6 (5) A Gyproc Plank + Gyproc WallBoard x 8 6 (5) A Gyproc Sounloc x.5 75 x 8 59 (5) A minutes fire resistance 5 Gyproc Sounloc x 5 75 x 8 58 (5) A Gyproc Sounloc x 5 75 x 8 60 (5) A Gyproc Plank + Gyproc Sounloc x 8 60 (5) A060 These systems have an ACTIVair board option available for formaldehyde control to improve indoor air quality. Alternatively, all systems can be skim finished with Thistle PureFinish which contains ACTIVair technology. Refer to the indoor air quality section in Background & theory. NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum Technical Advice Centre tel:

11 Internal partitions loadbearing One layer of board each side of timber studs at 600mm centres. 5mm Isover Acoustic Partition Roll (APR 00) and board linings as in table. Two layers of board each side of timber studs at 600mm centres. 5mm Isover Acoustic Partition Roll (APR 00) and board linings as in table. Table.7a 75mm and 00mm timber stud partitions solutions to satisfy the requirements of 76: Part : 987 Detail Partition Board Available Lining Minimum Maximum Sound insulation R w System thickness type with ACTIVair thickness stud size load ratio without with reference mm technology mm mm insulation insulation 0 minutes fire resistance 00 Gyproc WallBoard x.5 75 x 8 60% 5 6 A0600/ Gyproc Sounloc x.5 75 x 8 60% 8 0 A060/06 05 Gyproc Sounloc x 5 75 x 8 60% 0 A060/07 5 Gyproc WallBoard x.5 75 x 8 60% 8 A0600/007 5 Gyproc Sounloc x.5 75 x 8 60% 6 A0605/08 0 Gyproc FireLine x 5 00 x 50 55% 8 A060 0 minutes fire resistance 60 Gyproc FireLine x 5 00 x 50 55% A0605 Table.7b 75mm timber stud partitions solutions to satisfy the requirements of 65-: 999 Detail Partition Board Available Lining Minimum Maximum Sound insulation R w System thickness type with ACTIVair thickness stud size load ratio without with reference mm technology mm mm insulation insulation 0 minutes fire resistance 05 Gyproc WallBoard x 5 75 x 8 60% 7 0 A0600/ Gyproc Sounloc x 5 75 x 8 60% 0 A060/07 5 Glasroc F MULTIBOARD x 0 75 x 8 60% 8 G Gyproc FireLine x.5 75 x 8 60% 8 A0608/09 90 minutes fire resistance 5 Glasroc F MULTIBOARD x.5 75 x 8 60% 7 G Gyproc FireLine x 5 75 x 8 00% 8 A0600/0 These systems have an ACTIVair board option available for formaldehyde control to improve indoor air quality. Alternatively, all systems can be skim finished with Thistle PureFinish which contains ACTIVair technology. Refer to the indoor air quality section in Background & theory. NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. bgtechnical.enquiries@bpb.com 09

12 Internal partitions non-loadbearing One layer of board each side of timber studs at 600mm centres. 5mm Isover Acoustic Partition Roll (APR 00) and linings as in table. Two layers of board each side of timber studs at 600mm centres. 5mm Isover Acoustic Partition Roll (APR 00) and linings as in table. Remedial treatment on one side of existing plasterboard partition (minimum x.5mm plasterboard each side of 75mm x 8mm studs at 600mm centres) using 50mm x 50mm timber battens at 600mm centres, with 50mm Isover Acoustic Partition Roll (APR 00) between the studs with Gypframe RB Resilient Bar at 600mm centres (fixed horizontally). Linings as in table. One layer of board each side of timber studs at 600mm centres and 65mm Isover Acoustic Partition Roll (APR 00) in the cavity. Linings as in table. Table.8a 6mm, 75mm and 00mm timber stud partitions solutions to satisfy the requirements of 76: Part : 987 Detail Partition Board Available Lining Minimum Sound insulation R w System thickness type with ACTIVair thickness stud size without with reference mm technology mm mm insulation insulation 0 minutes fire resistance 88 Gyproc Sounloc x.5 6 x 8 0 A Gyproc WallBoard x.5 6 x 8 A060 9 Gyproc Sounloc x 5 6 x 8 0 A Gyproc WallBoard x 5 6 x 8 0 A Gyproc WallBoard x.5 75 x A0600/ Gyproc Sounloc x.5 75 x A060/06 05 Gyproc Sounloc x 5 75 x 8 0 A060/07 5 Gyproc WallBoard x.5 75 x 8 8 A0600/007 5 Gyproc Sounloc x.5 75 x 8 6 A0605/08 0 Gyproc FireLine x 5 00 x 50 8 A Gyproc Sounloc x 5 75 x 8 5 A050 0 minutes fire resistance 60 Gyproc FireLine x 5 00 x 50 A0605 Stud sizes quoted are minimum. 5mm Isover Acoustic Partition Roll (APR 00) insulation. These systems have an ACTIVair board option available for formaldehyde control to improve indoor air quality. Alternatively, all systems can be skim finished with Thistle PureFinish which contains ACTIVair technology. Refer to the indoor air quality section in Background & theory. NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. 0 Technical Advice Centre tel:

13 One layer of board each side of timber studs at 600mm centres. 5mm Isover Acoustic Partition Roll (APR 00) and linings as in table. Two layers of board each side of timber studs at 600mm centres. 5mm Isover Acoustic Partition Roll (APR 00) and linings as in table. Remedial treatment on one side of existing plasterboard partition (minimum x.5mm plasterboard each side of 75mm x 8mm studs at 600mm centres) using 50mm x 50mm timber battens at 600mm centres, with 50mm Isover Acoustic Partition Roll (APR 00) between the studs with Gypframe RB Resilient Bar at 600mm centres (fixed horizontally). Linings as in table. Table.8b 6mm, 75mm and 00mm timber stud partitions solutions to satisfy the requirements of 6-: 999 Detail Partition Board Available Lining Minimum Sound insulation R w System thickness type with ACTIVair thickness stud size without with reference mm technology mm mm insulation insulation 0 minutes fire resistance 88 Gyproc Sounloc x.5 6 x 8 0 A Gyproc Sounloc x 5 6 x 8 0 A Gyproc WallBoard x 5 6 x 8 0 A Gyproc WallBoard x 5 75 x A0600/6 05 Gyproc Sounloc x 5 75 x 8 0 A060/7 5 Glasroc F MULTIBOARD x 0 75 x 8 8 G Gyproc FireLine x.5 75 x 8 8 A0608/9 96 Gyproc Sounloc x 5 75 x 8 5 A minutes fire resistance 5 Glasroc F MULTIBOARD x.5 75 x 8 7 G Gyproc FireLine x 5 75 x 8 8 A0600/ Stud sizes quoted are minimum. 5mm Isover Acoustic Partition Roll (APR 00) insulation. These systems have an ACTIVair board option available for formaldehyde control to improve indoor air quality. Alternatively, all systems can be skim finished with Thistle PureFinish which contains ACTIVair technology. Refer to the indoor air quality section in Background & theory. NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. bgtechnical.enquiries@bpb.com

14 External walls 00mm brick outer, 50mm clear cavity, 9mm OSB. 0mm x 8mm timber studs at maximum 600mm centres. Timber stud fully-filled with 0mm Isover Frame Batt, Isover Vario. Linings as in table. 0mm render, 00mm medium block ( l=0.6w/mk), 50mm clear cavity, 9mm OSB. 0mm x 8mm timber studs at maximum 600mm centres. Timber stud fully-filled with 0mm Isover Frame Batt, Isover Vario. Linings as in table. Cladding on battens well ventilated, 9mm OSB. 0mm x 8mm timber studs at maximum 600mm centres. Timber stud fully-filled with 0mm Isover Frame Batt, Isover Vario. Linings as in table. Table.9a Timber frame Detail Board Lining U-value Fire resistance Fire resistance System type thickness mm (W/m K) () minutes () minutes reference Gyproc Sounloc or Gyproc FireLine x B Gyproc Sounloc or Gyproc FireLine x B60600 Gyproc Sounloc or Gyproc FireLine x B Table.9b Timber frame with enhanced impact performance Detail Board Lining U-value Fire resistance Fire resistance System type thickness mm (W/m K) () minutes () minutes reference Gyproc DuraLine x B Gyproc DuraLine x B60600 Gyproc DuraLine x B Gyproc FireLine x B Gyproc FireLine x B Gyproc FireLine x B Gyproc Sounloc or Gyproc WallBoard x A Gyproc Sounloc or Gyproc WallBoard x A Gyproc Sounloc or Gyproc WallBoard x A Table.9c Timber frame with enhanced impact performance Detail Board Lining U-value Fire resistance Fire resistance System type thickness mm (W/m K) () minutes () minutes reference Rigidur H x B60600 Rigidur H x B6060 Rigidur H x B6060 NB Systems presented are typical solutions. For specific U-value and condensation risk calculations, please contact the British Gypsum Technical Advice Centre at bgtechnical.enquiries@bpb.com Based on Building Research Establishment Document BR8 report (988) guidelines, as referenced in Building Regulations Approved Document B. 0 minutes loadbearing capacity, 0 minutes integrity, 5 minutes insulation. 60 minutes loadbearing capacity, 60 minutes integrity, 5 minutes insulation. These systems have an ACTIVair board option available for formaldehyde control to improve indoor air quality. Alternatively, all systems can be skim finished with Thistle PureFinish which contains ACTIVair technology. Refer to the indoor air quality section in Background & theory. Technical Advice Centre tel:

15 Not just today. NEW Code Level CfSH External Timber Frame Wall Solution. Not just for today, but for generations to come. Achieve Level for energy of the Code for Sustainable Homes and eliminate thermal bridging with Isover s Timber Frame Wall Solution. Providing features the Isover Vario air tightness membrane for enhanced performance of the building envelope. For further information visit: Isover Vario can help to reduce heat loss through the building envelope to a tenth of that of a conventional house and is ideal for use in Passive House constructions and buildings with Mechanical Ventilation Heat Recovery systems. A solution Not just for today with an overall construction U-value of 0.W/m k. Brick outer leaf 0mm Timber Stud 0mm Isover Timber Frame Batt 0mm Isover Vario Air Tightness Membrane Plasterboard.5mm Gyproc WallBoard Isover Acoustic Partition Roll (APR 00) 50mm bgtechnical.enquiries@bpb.com

16 Ceiling membranes 8mm (minimum) timber joists or 5mm (minimum) bottom chord of trusses at 600mm centres, with suitable timber noggings between joists to support board edges. Insulation laid between joists (see table). Linings as in table. 8mm (minimum) timber joists or 5mm (minimum) bottom chord of trusses at 600mm centres, with suitable timber noggings between joists to support board edges. Insulation laid between joists (see table). Linings as in table. 8mm (minimum) timber joists or 5mm (minimum) bottom chord of trusses at 600mm centres, with suitable timber noggings between joists to support board edges. Insulation laid between joists (see table). Linings as in table. 5 CasoLine MF suspended from joists. Insulation laid over ceiling grid. Linings as in table. CasoLine MF suspended from joists. Insulation laid over ceiling grid. Linings as in table. Table.0a Direct fix to joists / bottom chord of trusses below the roof space. Solutions to satisfy the requirements of 76: Part : 987 Detail Board Ceiling lining Noggings Insulation System type thickness mm required type reference 0 minutes fire resistance Gyproc WallBoard x.5 Yes 50mm Isover Spacesaver Ready-Cut C0609 Gyproc FireLine x.5 Yes 50mm Isover Spacesaver Ready-Cut C0607 Gyproc WallBoard x.5 No 00mm Isover Spacesaver Ready-Cut C Gyproc FireLine x.5 Yes 50mm stone mineral wool (kg/m ) C0608 Gyproc FireLine x 5 No 0mm stone mineral wool (5kg/m ) C0605 Table.0b Direct fix to joists / bottom chord of trusses below the roof space. Solutions to satisfy the requirements of 6-: 999 Detail Board Ceiling lining Noggings Insulation System type thickness mm required type reference 0 minutes fire resistance Gyproc WallBoard x 5 Yes 50mm Isover Spacesaver Ready-Cut C0605 Gyproc FireLine x.5 Yes 50mm stone mineral wool (kg/m ) C0608 Nominal 50mm x 5mm timber battens should be fixed to the side of timber supports where the ceiling boards butt to maintain an adequate bearing surface. At ceiling perimeter and to support outer layer ceiling board joints. The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. Where boards are fixed direct to timber joists, Drywall Timber Screws should be used as opposed to nail-fixing to minimise the risk of fixing defects occurring. Technical Advice Centre tel:

17 Construction details Separating wall and external wall junction (plan) Separating wall and internal wall junction (plan) Separating wall T junction (plan) Separating wall corner (plan) 5 Gyproc plasterboard Timber framing Isover insulation Isover cavity barrier Sheathing board 6 7 External wall cavity External cladding bgtechnical.enquiries@bpb.com 5

18 Construction details 5 Separating wall and separating floor junction (section) 6 Separating floor and external wall junction (section) Separating floor and loadbearing internal wall 8 Separating floor and non-loadbearing internal wall junction (section) junction (section) Gyproc plasterboard Timber framing Isover insulation Isover cavity barrier Sheathing board External wall cavity External cladding Gypframe Resilient Bars Gyproc Sealant Bulk-fill with Gyproc jointing materials (where gap exceeds 5mm) 5mm resilient flanking strip Resilient battens / floating floor Timber joist Gypframe Resilient Bar noggings Gyproc Plank Walking surface Timber-based sub-deck 6 Technical Advice Centre tel:

19 9 Sockets in separating wall 0 Sockets in sacrificial lining to separating wall 6 Services in separating wall Corner Gyproc plasterboard Timber framing Isover insulation Electrical socket box Services Timber batten bgtechnical.enquiries@bpb.com 7

20 T junction between studs T junction at stud Gyproc plasterboard Timber framing Isover insulation Timber noggings at 600mm centres 8 Technical Advice Centre tel:

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction C05. S03. P02 P08 Including C05. S01. P02 Specialist partitions introduction C05 Specialist partitions Introduction Specialist partitions This section details specialist lightweight systems where high-security,

More information

FireWall. High performance fireresistant. FireWall. www.british-gypsum.com

FireWall. High performance fireresistant. FireWall. www.british-gypsum.com FireWall FireWall High performance fireresistant wall system FireWall is a non-loadbearing wall which provides up to 240 minutes fire resistance. It is used in certain ground floor basement situations

More information

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available. APR 1200 Acoustic Partition Roll CI/Sfb Ref: APR002 Glass mineral wool roll designed to provide high levels of sound insulation in walls and floors to meet Part E (England & Wales) and Section 5 (Scotland)

More information

British Gypsum Guide to Timber Frame Construction. March 1998

British Gypsum Guide to Timber Frame Construction. March 1998 British Gypsum Guide to Timber Frame Construction March 1998 Timber frame construction has a centuries long tradition in the UK, however, over the last 80 years it has continuously evolved to meet the

More information

Rockwool Flexi Insulation Application Guide

Rockwool Flexi Insulation Application Guide Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed

More information

C09. S02. P02 P14 CasoLine mf. Including C09. S01. P02 P08 Sound absorbing solutions introduction

C09. S02. P02 P14 CasoLine mf. Including C09. S01. P02 P08 Sound absorbing solutions introduction C09. S0. P0 P Including C09. S0. P0 P08 Sound absorbing solutions introduction C09 Sound absorbing solutions Introduction Sound absorbing solutions This section details sound absorbing solutions which

More information

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory

More information

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and

More information

Manual lifting and handling

Manual lifting and handling Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details

More information

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02

More information

Guide to domestic building renovation. Telephone: 0844 800 1991 Fax: 0844 561 8816 Email: bgtechnical.enquiries@bpb.com

Guide to domestic building renovation. Telephone: 0844 800 1991 Fax: 0844 561 8816 Email: bgtechnical.enquiries@bpb.com BRITISH GYPSUM A BUSINESS SUPERBRAND SINCE 2008 Gyproc, Thistle, Gypframe and Glasroc are all registered trade names of BPB United Kingdom Limited. Isover is a registered trade name of Saint-Gobain. Proprietor:

More information

Module 3.7. Thermal bridging

Module 3.7. Thermal bridging Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal

More information

Rev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org

Rev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org Rev 1-12.2013 Code of Practice SIP Technology www.uksips.org What are Structural Insulated Panels (SIPS)? SIPS are prefabricated, high performance, lightweight, building panels that can be used in floors,

More information

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37 Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details

More information

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,

More information

Energy Company Obligation (ECO): Technical Monitoring Questions

Energy Company Obligation (ECO): Technical Monitoring Questions Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified

More information

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details D Installation Details D1 General D2 Walls D3 Ceilings D4 Reference D Installation Details D Contents D1 General Installation and Fastening Sequence for Steel Studs D1.1 Fastener Selection D1.3 D2 Walls

More information

CasoLine QUICK-LOCK grid systems

CasoLine QUICK-LOCK grid systems CasoLine QUICK-LOCK grid systems CasoLine QUICK-LOCK T grid 90-0mm up to 000-00mm Tile edge details swg CasoLine QUICK-LOCK T/8 000mm CasoLine QUICK-LOCK T/8 600mm A Gyprex / Gyptone CasoLine QUICK-LOCK

More information

Glasroc F multiboard Five high performances in one board

Glasroc F multiboard Five high performances in one board Glasroc F multiboard Five high performances in one board Glasroc F multiboard is non-combustible and depending on which of the three thickness you use can give you up to 120 minutes fire resistance. Great

More information

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01. Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice

More information

H-Stud Area Separation Wall System

H-Stud Area Separation Wall System 12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic

More information

Multi-layer Insulation Blanket for Roofs

Multi-layer Insulation Blanket for Roofs Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

Partitioning & Ceiling Product Information

Partitioning & Ceiling Product Information Partitioning & Ceiling Product Information tel + 44 (0) 1384 412448 fax + 44 (0) 1384 4494 email enquiries@drywallsteelsections.co.uk web www.drywallsteelsections.co.uk tel + 44 (0) 1384 412448 fax + 44

More information

How To Certify The Scottsdale Construction System

How To Certify The Scottsdale Construction System BRE CERTIFICATION LIMITED PRODUCT SCOTTSDALE CONSTRUCTION SYSTEM CERTIFICATE NUMBER 129/07 DATE OF ISSUE December 2007 SUPPLIED BY Scottsdale Construction System Ltd SUMMARY The Scottsdale Construction

More information

Report Number BTC 17755F

Report Number BTC 17755F Leics. LE NP Tel () 4 Fax () 4 Email btc.testing@saintgobain.com Report Number BTC 77F A FIRE RESISTANCE TEST ON A LOADBEARING TIMBER JOIST FLOOR INCORPORATING 4mm x 7mm x 47mm SOLID JOISTS PROTECTED BY

More information

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION Bill Robinson BSc. C. Eng. M. I. Struct. E. Timber Design Services 1 IS440 Timber frame

More information

The Pocket Guide To Insulation August 2013

The Pocket Guide To Insulation August 2013 The Pocket Guide To Insulation August 2013 Introduction Knauf Insulation is the UK s leading manufacturer of insulation products, including: Earthwool glass and rock mineral wool Polyfoam ECO extruded

More information

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength. INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal

More information

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors For distribution in Asia Pacific PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors Contents

More information

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing Good Craftsmanship Guide Carpentry and Joinery- Carcassing Introduction This Good Craftsmanship Guide highlights key problems with the major elements of Carpentry and Joinery - Carcassing, and gives guidance

More information

Gypsum Board Systems Manual

Gypsum Board Systems Manual CertainTeed Gypsum Board Systems Manual Fire Resistance and Sound Control Design Manual Division 09 GYPSUM BOARD SYSTEMS MANUAL TABLE OF CONTENTS Introduction General Fire Resistance...1 Sound Control...3

More information

2014 British Columbia Building Code Changes

2014 British Columbia Building Code Changes District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most

More information

Ecojoist. Practical benefits of Ecojoist. www.eleco.com/gang-nail

Ecojoist. Practical benefits of Ecojoist. www.eleco.com/gang-nail Ecojoist Practical benefits of Ecojoist. www.eleco.com/gang-nail Gang-Nail Systems, an Eleco plc company, offer integrated solutions f the timber engineering industry which assist in reducing design, production

More information

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver Designing an Effective Envelope Roofs Below Grade Walls and slabs Glazing & Windows Opaque portions of walls 2 3 Energy

More information

CertainTeed. Shaftliner For A rea Separation Firewalls

CertainTeed. Shaftliner For A rea Separation Firewalls CertainTeed Shaftliner For A rea Separation Firewalls M2Tech Shaftliner Type X for Area Separation M2Tech Shaftliner is a specially formulated product for applications where enhanced mold resistance is

More information

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01 Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal

More information

Lightweight Partition Design for Residential and Commercial Buildings

Lightweight Partition Design for Residential and Commercial Buildings Lightweight Partition Design for Residential and Commercial Buildings Stanley D. Gatland II, CertainTeed Corporation, Valley Forge, Pennsylvania Guidelines are presented for the design and proper installation

More information

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS NOISE TECHNICAL FACT SHEET FACT SHEET 5 SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS The sound insulation of exterior walls and roof-ceiling systems refers to their ability to reduce external

More information

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed

More information

Timber Frame Walls Rethinking Construction

Timber Frame Walls Rethinking Construction Insulation Fifth Issue November 2007 Timber Frame Walls Rethinking Construction INSULATION BEST PRACTICE FOR THE 21ST CENTURY Summary 9 mm OSB sheathing 3 mm skim coated 15 mm plasterboard Rock or glass

More information

Wood-frame Construction, Fire Resistance and Sound Transmission

Wood-frame Construction, Fire Resistance and Sound Transmission Fire Resistance and Sound Transmission For many years, wood-frame construction has been providing Canadians with high-quality, affordable housing. This goes from town houses to multi-storey apartment buildings,

More information

Timber Frame Construction

Timber Frame Construction Timber Frame Construction Introduction Design and Detailing What is timber? Failure modes History of timber frame construction Forms of timber frame construction Live and dead loads Wind loads Roof construction

More information

Building Regulations for the Conservation of Fuel and Power

Building Regulations for the Conservation of Fuel and Power Insulation CI/SfB Rn7 M2 First Issue April 2014 Building Regulations for the Conservation of Fuel and Power ENGLAND EXISTING DWELLINGS 2013 EDITION Low Energy Low Carbon Buildings Contents Page Introduction

More information

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX TECHNICAL CHARACTERISTICS Multi-Foil Reflective Insulation Xfoil Range of insulation is designed to achieve

More information

GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS

GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS CONTENTS Introduction 2 Applications 3 Advantages 3 Components 3 6 Design Considerations 7 8 System Features 10 Typical installation Sequence

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5 Accredited Construction Details (Scotland) 2010 For the limitation of thermal bridging and air infiltration in low and medium rise domestic buildings Introduction & Principles Issued in support of Junction

More information

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,

More information

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. This leaflet provides guidance on how to attain compliance with The Building (Amendment) Regulations (Northern Ireland) 2006, Part

More information

Fire safety in timber buildings

Fire safety in timber buildings Fire safety in timber buildings Introduction Fire spread in buildings is a risk to life safety for which the Building Regulations (for England and Wales 1,2, Scotland 3 and Northern Ireland 4 ) aims to

More information

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation

More information

Internal wall insulation in existing housing

Internal wall insulation in existing housing Energy Efficiency Best Practice in Housing Internal wall insulation in existing housing A guide for specifiers and contractors Cost-effective External wall appearance maintained Easier to install and maintain

More information

Composite Panel Firewall Systems

Composite Panel Firewall Systems Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.

More information

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas Powerpanel H 2 O is a cement based board from FERMACELL. Board Characteristics Board Thickness 12.5 mm Board Sizes 1000 x 1200 mm 50 sheets/pallet

More information

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally

More information

Post-insulation of cellar ceiling and cellar walls

Post-insulation of cellar ceiling and cellar walls WP5 Education and Economic Promotion Post-insulation of cellar ceiling and cellar walls Educational product: New lecture material for training modules dealing with knowledge and skills how to apply suitable

More information

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein

More information

TECHNICAL RECOMMENDATION

TECHNICAL RECOMMENDATION TECHNICAL RECOMMENDATION NO: 9 DESIGN OF LIGHT TIMBER FRAMED WALLS AND FLOORS FOR FIRE RESISTANCE Peter Collier Contents Design of Light Timber Framed Walls and Floors for Fire Resistance Relevance Acceptance

More information

DEFAULT HEAT LOSS COEFFICIENTS

DEFAULT HEAT LOSS COEFFICIENTS DEFAULT HEAT LOSS COEFFICIENTS SECTION A101 GENERAL REQUIREMENTS A101.1 Scope. The following defaults shall apply to Chapter 4 of both the (RE) and (CE) sections of the IECC. This chapter includes tables

More information

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability 1/9/13 By Brett T. Fagan, P.E. Presented by Marie Horan, P.E. Building Diagnostics, Inc. Building Diagnostics Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

More information

Controlling the Transmission of Impact Sound through Floors

Controlling the Transmission of Impact Sound through Floors Construction Technology Update No. 35 Controlling the Transmission of Impact Sound through Floors by A.C.C. Warnock This Update presents guidelines for controlling the transmission of impact sound through

More information

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

NRG 75 CRF NRG GREENBOARD WALL SYSTEM NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark

More information

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia E-mail: info@usgme.com Fax: +966 3 8121029 +966 3 8120995

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia E-mail: info@usgme.com Fax: +966 3 8121029 +966 3 8120995 USG Middle East, Ltd. Dammam, Saudi Arabia E-mail: info@usgme.com Fax: +966 3 8121029 +966 3 8120995 Riyadh, Saudi Arabia E-mail: riyadhsales@usgme.com Fax: +966 1 4772734 +966 1 4772734 Jeddah, Saudi

More information

Guide to Assessment and Repair of Flood Damaged Timber and Timber Framed Houses

Guide to Assessment and Repair of Flood Damaged Timber and Timber Framed Houses Technical Guide Guide to Assessment and Repair of Flood Damaged Timber and Timber Framed Houses ASSESSMENT OF DAMAGE Prior to any assessments or repairs being commenced, a licensed electrician must undertake

More information

Building Systems by Stora Enso. Residential multi-storey buildings

Building Systems by Stora Enso. Residential multi-storey buildings Building Systems by Stora Enso Residential multi-storey buildings Table of contents 1 Introduction and disclaimer... 3 1.1 Introduction... 4 1.2 The benefits of the system... 5 1.3 Disclaimer... 5 2 Anatomy

More information

The White Book Refurbishment Guide Effective ways to repair, maintain and improve buildings.

The White Book Refurbishment Guide Effective ways to repair, maintain and improve buildings. The White Book Refurbishment Guide Effective ways to repair, maintain and improve buildings. Welcome to the first edition of The White Book Refurbishment Guide. Within this guide we have compiled an overview

More information

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1 Top plate Stud Soffit lining 45mm min nog Fix scotia bead Building underlay/james Hardie rigid air barrier Soffit Detail Building underlay/james Hardie rigid air barrier Bottom plate 25mm wide cant strip.

More information

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs The better way to build TM Installation Manual EXTERIOR WALL SIPs July 2015 EXTERIOR WALL SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................

More information

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035 Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí

More information

Fire Protection. CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8. Floor Assembly No.

Fire Protection. CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8. Floor Assembly No. BULLETIN No. 28 (a) Fire Protection CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8 Floor Assembly No. NRC764-FF22 Fire Endurance Period 1 74 minutes Sound

More information

CI/SfB 2- Rj7 December 2010

CI/SfB 2- Rj7 December 2010 Engineered Timber Systems CI/SfB 2- Rj7 December 2010 STANDARD DETAILS Contents Wall Details W1 Typical wall section. W2 a Sectional elevation through soleplate fixing detail. Ground bearing slab. W2 b

More information

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: general.enquiries@kil.kingspan.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION: 06 05 83 SHOP APPLIED WOOD COATINGS SECTION: 06 16 00 SHEATHING REPORT HOLDER:

DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION: 06 05 83 SHOP APPLIED WOOD COATINGS SECTION: 06 16 00 SHEATHING REPORT HOLDER: 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 1365 Reissued 04/2016 This report is subject to renewal 04/2017. DIVISION: 06 00 00 WOOD, PLASTICS

More information

Fire Resistance of Brick Masonry

Fire Resistance of Brick Masonry TECHNICAL NOTES on Brick Construction 1850 Centennial Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 Fire Resistance of Brick Masonry 16 March 2008 Abstract: This Technical Note presents

More information

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS 1 Ralf Lindberg, Professor Minna Korpi, M.Sc. Juha Vinha, Dr.Tech. June 11, 2008 Department of Civil Engineering, Tampere University of Technology 2 BACKGROUND

More information

The FIRE BOOK. Passive fire protection solutions

The FIRE BOOK. Passive fire protection solutions The FIRE BOOK Passive fire protection solutions The importance of providing effective fire protection to buildings cannot be over-emphasised. The consequences of a fire occurring in a building, without

More information

Heating Load Calculation

Heating Load Calculation Heating Load Calculation ME 425 Air Conditioning System Design Keith E. Elder, P.E. Heating Load Calculation The heating load calculation begins with the determination of heat loss through a variety of

More information

Conventions for U-value calculations

Conventions for U-value calculations Conventions for U-value calculations 2006 edition Brian Anderson BRE Scotland BRE is committed to providing impartial and authoritative information on all aspects of the built environment for clients,

More information

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls. Improving the flood resistance of your home Advice sheet 4: Flood-resilient walls. This sheet provides guidance on identifying different types of wall, and reducing the flow of floodwater through them

More information

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight

More information

Finishing guide. For Thistle plaster and Gyproc plasterboard. Telephone: 08705 456123 Fax: 08705 456356 Email: bgtechnical.enquiries@bpb.

Finishing guide. For Thistle plaster and Gyproc plasterboard. Telephone: 08705 456123 Fax: 08705 456356 Email: bgtechnical.enquiries@bpb. BUSINESS SUPERBRAND SINCE 008 Gyproc, Thistle, Gypframe and Glasroc are all registered trade names of BPB United Kingdom Limited. Isover is a registered trade name of Saint-Gobain. Proprietor: BPB United

More information

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors Roxul Safe n Sound Sound Control and Fire Safety From One Batt Insulation Roxul

More information

Rockwool Cladding Roll

Rockwool Cladding Roll Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F

More information

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES CERTIFICATE OF APPROVAL No CF 5055 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 1 st Industrial Area,

More information

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors. Fire & Soundproofing Insulation Roxul SAFE N SOUND Fire and Soundproofing Insulation for Interior Partition Walls and Floors. Roxul SAFE N SOUND Sound control and fire safety from one batt Insulation.

More information

Steel-framed Walls. Insulation

Steel-framed Walls. Insulation Insulation A4/8 SF AW1192 Issue 4 Nov 2012 Steel-framed Walls Insulation guide Helps achieve a 6-star house energy rating Rigid and flexible Kingspan AIR-CELL solutions available Vapour barrier or vapourpermeable

More information

Sports Buildings: budget costs for the Flood Relief Fund

Sports Buildings: budget costs for the Flood Relief Fund Sports Buildings: budget costs for the Flood Relief Fund The list below provides typical costs for flood insurance works, typically required by sports clubs or facilities. The list is not exhaustive but

More information

Building Control Guidance Note

Building Control Guidance Note Elements Renovation / Replacement. Issued 25/01/13 Rev a Page 1 of 9 (Applies to both Domestic and Non-Domestic Premises) Works relating to thermal elements can arise in building an extension, a material

More information

Renovating Your Basement

Renovating Your Basement building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:

More information

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER User note: Code change proposals to this chapter will be considered by the IBC Structural Code Development Committee during the 2016 (Group B)

More information

GYPSUM BOARD AND PLASTER

GYPSUM BOARD AND PLASTER CHAPTER 25 GYPSUM BOARD AND PLASTER SECTION 2501 GENERAL 2501.1 Scope. 2501.1.1 General. Provisions of this chapter shall govern the materials, design, construction and quality of gypsum board, lath, gypsum

More information

FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS

FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS INFORMATION PAPER IP 21/10 FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS Tom Lennon and Danny Hopkin The use of Structural Insulated Panel (SIP) systems in construction in the UK has increased

More information

How To Repair A Boat Landing Deck With A Boat Bed

How To Repair A Boat Landing Deck With A Boat Bed RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing

More information

Providing protection in construction

Providing protection in construction Providing protection in construction VOLUME 2: WALLS AND FLOORS Contact Information UK office address: DuPont Tyvek Hither Green Trading Estate Clevedon, North Somerset BS21 6XU Tel: 01275 879770 Fax (sales):

More information

sound reduction systems for commercial, educational and industrial environments

sound reduction systems for commercial, educational and industrial environments sound reduction systems for commercial, educational and industrial environments Tel: +44 ()14 3874 Fax: +44 ()14 38957 E-mail: info@soundreduction.co.uk Web: www.soundreduction.co.uk soundblocker Acoustic

More information

PRESTRESSED CONCRETE FLOORING BEAMS

PRESTRESSED CONCRETE FLOORING BEAMS PRESTRESSED CONCRETE FLOORING BEAMS TRIED & TRUSTED Introduction Established in 2001 TT Concrete Products Limited has become a prominent manufacturer of prestressed concrete flooring beams throughout the

More information

Post and Beam Construction

Post and Beam Construction Post and Beam Construction A Presentation By the Canadian Wood Council Canadian Conseil Wood canadien Council du bois Early settlers introduced the concept of post and beam construction in North America

More information