LIGHT GAUGE STRUCTURAL FRAMING & ACCESSORIES

Size: px
Start display at page:

Download "LIGHT GAUGE STRUCTURAL FRAMING & ACCESSORIES"

Transcription

1 LIGHT GAUGE STRUCTURAL FRAMING & ACCESSORIES 1

2 BUILDSTRONG LIGHT Gauge STRUCTURAL FRAMING & ACCESSORIES 2

3 LIGHT GAUGE STRUCTURAL FRAMING & ACCESSORIES TABLE OF CONTENTS Product Identification General Product Information Compliance Guaranteed Material Specifications Technical Assistance Thickness Steel Components Design Stiffening Lip Length General Notes for all Tables Definitions of Symbols Physical Properties Physical Properties Table Notes Non-Structural Stud Physical Properties Non-Structural Track Physical Properties Structural Stud Physical Properties Structural Track Physical Properties Limiting Wall Height Tables Limiting Wall Heights Non-Structural Wall Height Non-Structural Table Notes Limiting Wall Heights Structural Wall Height Structural Table Notes Curtain Wall Construction Details Axial Load Tables Allowable Axial Load Table Notes Allowable Axial Loads Construction Details Web Crippling Load Tables Web Crippling Load Table Notes Web Crippling Conditions Floor Joist Span Tables Allowable Floor Joist Span Table Notes Allowable Floor Joist Spans Floor Assembly Details Ceiling Span Table Ceiling Span Table Notes Ceiling Spans L/ Ceiling Spans L/ Channel Properties (CRC) Cold-Rolled Channel Physical Properties and Allowable Span Tables (DWFC) Drywall Furring Channel Physical Properties and Allowable Span Tables Header Load Tables Header Load Table Notes Header Allowable Uniform Loads Fastening Systems Screw Table Notes Allowable Loads for Screw Connections Weld Table Notes Allowable Loads for Fillet Welds and Flare Groove Welds.. 53 Powder Systems Accessories (CLT) Custom Leg Track, (FS) Flat Strapping, (WS) Web Stiffeners, (BC) Bridge Clip (RA) Rolled Angles, (CA) Clip Angles, (FC) Foundation Clip. 56 Architectural Specification Allowable Web Crippling Loads Single Members Allowable Web Crippling Loads Back-to-Back Members. 37 3

4 BUILDSTRONG COMPLIANCE IS GUARANTEED When you use Telling Industries, you are using the most up-to-date code compliant framing products available in the World International Building Code/2004 AISI-NASPEC ICC-ESR 2281 ICC-ES Certified Internationally recognized Verified by ICC Certified Inspectors at all facilities Cambridge, Ohio Osceola, Arkansas Kingman, Arizona ASTM International Telling meets or exceeds all applicable ASTM Framing Standards. A Standard Specification for Steel Sheet, Carbon, Metallic- and Nonmetallic-Coated for Cold-Formed Framing Members A Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy- Coated (Galvannealed) by the Hot-Dip Process Note: even though A does allow for the use of Galvannealed, Telling DOES NOT supply Galvannealed steel. C Standard Specification for Nonstructural Steel Framing Members C Standard Specification for Installation of Steel Framing Members to Receive Screw-Attached Gypsum Panel Products C Standard Specification for Load-Bearing (Transverse and Axial) Steel Studs, Runners (Tracks), and Bracing or Bridging for Screw Application of Gypsum Panel Products and Metal Plaster Bases C Standard Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories Industry Affiliations USGBC: Telling is an active Member of The United States Green Building Council Many More: SFA, AWCI, AISI, ASTM and LGSEA 4

5 LIGHT GAUGE STRUCTURAL FRAMING & ACCESSORIES PRODUCT IDENTIFICATION SECTION PROPERTIES PRODUCT IDENTIFICATION All Telling Industries products contain a four part identification code. This identifies the size (both depth and flange/leg height), style, and material thickness of each member. EXAMPLE: WEB DEPTH: (Example: 6 = 600 x 1/100 inches) All member depths are taken in 1/100 inches. For all T sections member depths is the inside to inside dimension. MATERIAL THICKNESS: (Example: in. = 54 mils = 16 gauge; 1 mil = 1/1000 in.) Material thickness is the minimum base metal thickness in mils. Minimum base metal thickness represents 95% of the design thickness. 600 S STYLE: (Example: Stud or Joist section = S) The two alpha characters utilized by the identification code are: S= Stud or Joist Sections T= Track Sections FLANGE/LEG HEIGHT: (Example: 1 5/8 = ~ 162 x 1/100 inches) All flange widths are taken in 1/100 inches. Note: For those sections where two different yield strengths (33 ksi and 50 ksi) are shown, the yield strength used in the design, if greater than 33 ksi, should be identified on the design and ordering of steel. (i.e., 600S162(50 ksi) THICKNESS - STEEL COMPONENTS Minimum Thickness 1 (mils) Design Thickness (in) Inside Corner Radii (in) Reference Only Gauge No. Color Coding Mill Black Drywall White Structural White Yellow Green Orange Red DESIGN STIFFENING LIP LENGTH Section Flange Width Design Stiffening Lip Length (in) S / S / S /8 0.5 S S / S Minimum Thickness represents 95% of the design thickness and is the minimum acceptable thickness delivered to the job site based on Section A2.4 of the 2004 NASPEC. 5

6 BUILDSTRONG GENERAL PRODUCT INFORMATION RAW MATERIAL INFORMATION All Telling Industries products are formed from steel with a minimum yield strength of 33 or 50 KSI (1000 lbs per square inch). All products contained in this brochure are engineered to meet the 2001 Edition of the AISI (American Iron and Steel Institute) North American Specification for the Design of Cold- Formed Steel Structural Members. The same document was used to calculate the physical and structural properties of all products listed herein via allowable stress design criteria. TECHNICAL ASSISTANCE Technical assistance is available to Telling Industries customers when requested. A Telling Industries representative or design professional can review project specific load conditions and determine deflection criteria and lateral bracing conditions not discussed herein. Further, our representatives can assist purchasers and designers in economical applications for maximum efficiency. All information contained in this brochure is intended as a general guide for using Telling Industries products. This information should not be used in design or assembly without an independent assessment by a qualified design professional. Such an assessment is necessary to verify the suitability of a particular product for use in any load bearing application. Telling Industries assume no liability for failure resulting from the use or misapplications of any information contained herein. Detail drawings contained herein are for information only. Telling Industries reserve the right to make modifications, changes, additions or deletions to the information on any of our products without prior notice or obligation. For the latest product information or to verify availability, contact a Telling Industries representative. This brochure contains the latest information available at the time of printing. GENERAL NOTES FOR ALL TABLES 1. The strength increase due to cold work forming was incorporated for flexural strength as applicable per AISI A The moment of inertia for deflection is calculated at a stress which results in an effective section modulus such that the stress times that section modulus is equal to the allowable moment. This follows Procedure 1 of the AISI specification. 3. The yield stresses (33 ksi or 50 ksi) used to calculate the tabulated values are indicated in the tables. 4. When provided, factory punch-outs will be located along the centerline of the webs of the members and will have a minimum centerto-center spacing of 24. Punch-outs will have a maximum width = half the member web height (d/2) or 1 1/2, whichever is less, and a maximum length = 4. The minimum distance between the end of the member and the near edge of the web punch-out = 10 unless otherwise specified. 5. For those steels that have both 33 and 50 ksi listings, if the design is based upon 50 ksi, the 50 ksi steel needs to be specified by the designer/purchasers. (i.e., 362S (50 ksi) DEFINITIONS OF STRUCTURAL PROPERTY SYMBOLS GROSS PROPERTIES Ixx: Moment of inertia of the gross section about the X-X axis (strong axis). Rx: Radius of gyration of the gross section about the X-X axis. Iyy: Moment of inertia of the gross section about the Y-Y axis (weak axis). Ry: Radius of gyration of the gross section about the Y-Y axis. EFFECTIVE PROPERTIES Ixx: Moment of inertia for deflection calculations based on the Procedure 1 or Deflection Determination of the 2001 AISI Specification. Sxx: Effective section modulus about the X-X axis (strong axis) Stress = Fy Ma: Allowable Bending Moment- Based on the effective section modulus and the allowable stress including the strength increase from cold-work of forming (AISI A 7.2) where applicable. Va: Allowable Shear Load. Ycg: Maximum distance from the outside of the compression flange to the center of gravity of the effective section. TORSIONAL PROPERTIES J: St. Venant Torsional Constant. Cw: Torsional warping constant. Xo: Distance from the shear center to the centroid along the principal X-axis. Ro: Polar radius of gyration about the centroid principal axis. ß: 1- (Xo/Ro)2 SECTION PROPERTIES TABLE NOTES 1. The centerline bend radius is the greater of 2 times the design thickness or 3/ Web depth for track sections is equal to the nominal height plus 2 times the design thickness plus the bend radius. 3. Hems on non-structural track sections are ignored. 4. Effective properties incorporate the strength increase from the cold work of forming as applicable per AISI A Tabulated gross properties are based on the full-unreduced cross section of the studs, away from punch-outs. 6. For deflection calculations, use the effective moment of inertia. 7. For those steels that have both 33 and 50 ksi, the 50 ksi steel needs to be specified. (I.e., 362S137 (50 ksi)) 6

7 LIGHT GAUGE STRUCTURAL FRAMING & ACCESSORIES PHYSICAL PROPERTIES NON-STRUCTURAL STUD PHYSICAL PROPERTIES Design Gross Properties 33 ksi Effective Properties 50 ksi Effective Properties Torsional Properties Thickness Area Weight Ixx Rx Iyy Ry Ixx Sxx Ma Va Ycg Ixx Sxx Ma Va Ycg Jx1000 Cw Xo Ro Section (in) (in²) (lb/ft) (in 4 ) (in) (in 4 ) (in) (in 4 ) (in³) (in-k) (lb) (in) (in 4 ) (in³) (in-k) (lb) (in) (in 4 ) (in 6 ) (in) (in) ß 162S S S S S S S S S S S S S S S S S S S S S S S S S S125-18¹ S S S S S S S125-18¹ S S S S S S S125-18¹ S125-27¹ S S S S S S125-18¹ S125-27¹ S125-30¹ S125¹ S S S Section Property Table Notes 1. Web depth for track sections equals nominal depth plus 2 x design thickness plus bend radius 2. Hems on non-structural track sections are ignored 3. Effective properties include the strength increase from cold-work of forming per NASPEC section A7.2 where applicable 4. Tabulated gross properties are based on the full, unreduced section away from punchouts 5. Effective properties of all S sections based on punched sections. Track sections are considered unpunched 6. For deflection determination, use the effective moment of inertia. Effective moment of inertia is based on Procedure 1 of the NASPEC. 7. For sections with properties listed for both 33 ksi and 50 ksi yield point, the required yield point should be specified in the design documents 8. Where effective properties are not listed for a section at 33 or 50 ksi yield, web depth-to-thickness or flange width-to-thickness limits from the NASPEC are exceeded. Only gross properties are available. 9. Where section designations include a superscript 1, web height-to-thickness exceeds 200. Web stiffeners are required at all supports and concentrated loads. 7

8 BUILDSTRONG PHYSICAL PROPERTIES NON-STRUCTURAL TRACK PHYSICAL PROPERTIES Design Gross Properties 33 ksi Effective Properties Torsional Properties Thickness Area Weight Ixx Rx Iyy Ry Ixx Sxx Ma Va Ycg Jx1000 Cw Xo Ro Section (in) (in²) (lb/ft) (in 4 ) (in) (in 4 ) (in) (in 4 ) (in³) (in-k) (lb) (in) (in 4 ) (in 6 ) (in) (in) ß 162T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T125-18¹ T T T T150-18¹ T T T T200-18¹ T T T T125-18¹ T T T T150-18¹ T T T T200-18¹ T T T T125-18¹ T125-27¹ T T T150-18¹ T150-27¹ T T T200-18¹ T200-27¹ T T T125-18¹ T125-27¹ T125-30¹ T125¹ T150-18¹ T150-27¹ T150-30¹ T150¹ T200-18¹ T200-27¹ T200-30¹ T200¹ Note: 1 Web height-to-thickness ratio exceeds 200. Web stiffeners required at all supports and concentrated loads. 8

9 LIGHT GAUGE STRUCTURAL FRAMING & ACCESSORIES PHYSICAL PROPERTIES STRUCTURAL STUD PHYSICAL PROPERTIES Design Gross Properties 33 ksi Effective Properties 50 ksi Effective Properties Torsional Properties Thickness Area Weight Ixx Rx Iyy Ry Ixx Sxx Ma Va Ycg Ixx Sxx Ma Va Ycg Jx1000 Cw Xo Ro Section (in) (in²) (lb/ft) (in 4 ) (in) (in 4 ) (in) (in 4 ) (in³) (in-k) (lb) (in) (in 4 ) (in³) (in-k) (lb) (in) (in 4 ) (in 6 ) (in) (in) ß 250S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S Section Property Table Notes 1. Web depth for track sections equals nominal depth plus 2 x design thickness plus bend radius 2. Hems on non-structural track sections are ignored 3. Effective properties include the strength increase from cold-work of forming per NASPEC section A7.2 where applicable 4. Tabulated gross properties are based on the full, unreduced section away from punchouts 5. Effective properties of all S sections based on punched sections. Track sections are considered unpunched 6. For deflection determination, use the effective moment of inertia. Effective moment of inertia is based on Procedure 1 of the NASPEC. 7. For sections with properties listed for both 33 ksi and 50 ksi yield point, the required yield point should be specified in the design documents 8. Where effective properties are not listed for a section at 33 or 50 ksi yield, web depth-to-thickness or flange width-to-thickness limits from the NASPEC are exceeded. Only gross properties are available. 9. Where section designations include a superscript 1, web height-to-thickness exceeds 200. Web stiffeners are required at all supports and concentrated loads. 9

10 BUILDSTRONG PHYSICAL PROPERTIES STRUCTURAL STUD PHYSICAL PROPERTIES Design Gross Properties 33 ksi Effective Properties 50 ksi Effective Properties Torsional Properties Thickness Area Weight Ixx Rx Iyy Ry Ixx Sxx Ma Va Ycg Ixx Sxx Ma Va Ycg Jx1000 Cw Xo Ro Section (in) (in²) (lb/ft) (in 4 ) (in) (in 4 ) (in) (in 4 ) (in³) (in-k) (lb) (in) (in 4 ) (in³) (in-k) (lb) (in) (in 4 ) (in 6 ) (in) (in) ß 600S S S S S S S S S S S S S S S S S S S S S S S S137¹ S S S S S162¹ S S S S S200¹ S S S S S250¹ S S S S S S S S137¹ S137¹ S S S S162¹ S162¹ S S S S200¹ S200¹ S S S S250¹ S250¹ S S S S S S S137¹ S137¹ S137¹ S S S162¹ S162¹ S162¹ S S S200¹ S200¹ S200¹ S S S250¹ S250¹ S250¹ S S S300¹ S S S162¹ S S S200¹ S S S250¹ S S S300¹ S S See Properties Table Notes on Page

CPA Steel Stud Framing Page 1 of 11

CPA Steel Stud Framing Page 1 of 11 CPA Steel Stud Framing Page 1 of 11 STEEL STUD FRAMING General Requirements City of Palo Alto (CPA) Building Inspection Division 285 Hamilton Ave. Inspection Request: 650 329-2496 Building Division IVR#

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION TECHNICAL NOTE On Cold-Formed Steel Construction 1201 15th Street, NW, Suite 320 W ashington, DC 20005 (202) 785-2022 $5.00 Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006

More information

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally

More information

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems: Reading Assignment SLAB DESIGN Chapter 9 of Text and, Chapter 13 of ACI318-02 Introduction ACI318 Code provides two design procedures for slab systems: 13.6.1 Direct Design Method (DDM) For slab systems

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-05 40 00 (May 2015) ------------------------ Preparing Activity: NAVFAC Superseding UFGS-05 40 00 (May 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in

More information

Light Steel Framing (LSF) Product Information

Light Steel Framing (LSF) Product Information Light Steel Framing (LSF) Product Information tel + (0) 8 8 fax + (0) 8 09 email enquiries@drywallsteelsections.co.uk web www.drywallsteelsections.co.uk tel + (0) 8 8 fax + (0) 8 09 p. Drywall Steel Sections

More information

1.02 SYSTEM DESCRIPTION

1.02 SYSTEM DESCRIPTION 1 OF 7 MODULAR MEZZANINES GUIDE SPECIFICATIONS FOR PART 1 - GENERAL 1.01 RELATED WORK A. SECTION 03 30 00: Cast in Place Concrete (and Concrete Finishing) 1. The area where mezzanine is installed shall

More information

Connection Solutions

Connection Solutions Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction

More information

Formwork for Concrete

Formwork for Concrete UNIVERSITY OF WASHINGTON DEPARTMENT OF CONSTRUCTION MANAGEMENT CM 420 TEMPORARY STRUCTURES Winter Quarter 2007 Professor Kamran M. Nemati Formwork for Concrete Horizontal Formwork Design and Formwork Design

More information

Introduction. Background

Introduction. Background Introduction Welcome to CFS, the comprehensive cold-formed steel component design software. The endless variety of shapes and sizes of cold-formed steel members, combined with the complex failure modes

More information

Discipline: Structural Issued 04-26-06

Discipline: Structural Issued 04-26-06 California Department of General Services. Division of the State Architect. Product Acceptance Report STRUCTURAL SHEAR PANEL SURE-BOARD SERIES 200 PANELS PA-132 Discipline: Structural Issued 04-26-06 This

More information

ANCHOR: Metal securing device embedded or driven into masonry, concrete, steel or wood.

ANCHOR: Metal securing device embedded or driven into masonry, concrete, steel or wood. CONSTRUCTION TERMINOLOGY ANCHOR: Metal securing device embedded or driven into masonry, concrete, steel or wood. ANCHOR BOLT: Heavy, threaded bolt embedded in the foundation to secure sill to foundation

More information

SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING

SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,

More information

Partitioning & Ceiling Product Information

Partitioning & Ceiling Product Information Partitioning & Ceiling Product Information tel + 44 (0) 1384 412448 fax + 44 (0) 1384 4494 email enquiries@drywallsteelsections.co.uk web www.drywallsteelsections.co.uk tel + 44 (0) 1384 412448 fax + 44

More information

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig. 7.21 some of the trusses that are used in steel bridges

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig. 7.21 some of the trusses that are used in steel bridges 7.7 Truss bridges Fig. 7.21 some of the trusses that are used in steel bridges Truss Girders, lattice girders or open web girders are efficient and economical structural systems, since the members experience

More information

Screw Penetration Testing with the ProSTUD

Screw Penetration Testing with the ProSTUD Screw Penetration Testing with the ProSTUD 24 June 2010 Structural Testing and Research Inc. 498 Eagle St. N., Unit 6 Cambridge, ON, Canada, N3H 1C2 Tel: (519) 653-5255 www.starlabs.ca STaR Technical Report

More information

Detailing of Reinforcment in Concrete Structures

Detailing of Reinforcment in Concrete Structures Chapter 8 Detailing of Reinforcment in Concrete Structures 8.1 Scope Provisions of Sec. 8.1 and 8.2 of Chapter 8 shall apply for detailing of reinforcement in reinforced concrete members, in general. For

More information

DSM http://www.dsmmfg.com 1 (800) 886-6376

DSM http://www.dsmmfg.com 1 (800) 886-6376 DESIGN GUIDE FOR BENT SHEET METAL This guide discusses how the bends are made, what thicknesses of sheet metal are commonly used, recommended bend radius to use when modeling the part, some practical limits

More information

Nucor VR16 II TM Vertical Rib Standing Seam Roof System

Nucor VR16 II TM Vertical Rib Standing Seam Roof System Nucor VR16 II TM Vertical Rib Standing Seam Ro System www.nucorbuildingsystems.com Nucor VR16 II Vertical Rib Standing Seam Ro Perfect for the Marketplace The Nucor Building Systems VR16 II Ro Panel is

More information

STANDARD SPECIFICATIONS

STANDARD SPECIFICATIONS American National Standard SJI-K 1.1 STANDARD FOR OPEN WEB STEEL JOISTS, K-SERIES SECTION 1. SCOPE Adopted by the Steel Joist Institute November 4, 1985 Revised to November 10, 2003 - Effective March 01,

More information

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3. Pages identified with the NMBS Logo as shown above, have been produced by NMBS to assist specifiers and consumers in the application of New Millennium Building Systems Deck products. Pages identified with

More information

POST AND FRAME STRUCTURES (Pole Barns)

POST AND FRAME STRUCTURES (Pole Barns) POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:

More information

Safety Grating GSSG-13R GRIP STRUT. safety grating

Safety Grating GSSG-13R GRIP STRUT. safety grating Safety Grating GSSG-13R safety grating Table of Contents & Advantages Advantages.................................................... 2 Proof Of Performance...................................... 3 General

More information

Design of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column

Design of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column Design of reinforced concrete columns Type of columns Failure of reinforced concrete columns Short column Column fails in concrete crushed and bursting. Outward pressure break horizontal ties and bend

More information

H-Stud Area Separation Wall System

H-Stud Area Separation Wall System 12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic

More information

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab, DESIGN OF SLABS Dr. G. P. Chandradhara Professor of Civil Engineering S. J. College of Engineering Mysore 1. GENERAL A slab is a flat two dimensional planar structural element having thickness small compared

More information

AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels

AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels AISI No. 1008 1010 1012 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 10 1026 1027 1029 10 1035 1036 1037 1038 1039 10 1041 1042 1043

More information

LEGACY REPORT ER-5110. www.icc-es.org. ICC Evaluation Service, Inc. Reissued November 1, 2003. Legacy report on the 1997 Uniform Building Code

LEGACY REPORT ER-5110. www.icc-es.org. ICC Evaluation Service, Inc. Reissued November 1, 2003. Legacy report on the 1997 Uniform Building Code LEGACY REPORT Reissued November 1, 2003 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900

More information

DESCRIPTION. Stud Bolts for Pressure-Temperature Piping 2-1. General Purpose End-to-End Studs 2-2. Tap End Stud Bolts 2-3. Double End Stud Bolts 2-4

DESCRIPTION. Stud Bolts for Pressure-Temperature Piping 2-1. General Purpose End-to-End Studs 2-2. Tap End Stud Bolts 2-3. Double End Stud Bolts 2-4 DESCRIPTION PAGE B7 Studs and Nuts Stud Bolts for Pressure-Temperature Piping 2-1 General Purpose End-to-End Studs 2-2 Tap End Stud Bolts 2-3 Double End Stud Bolts 2-4 Sigma Fasteners, Inc. Section 2 STUD

More information

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE This specification is intended to describe the general requirements applicable to a proper structural mezzanine design. In addition, it is to serve as

More information

research report Residential Hip Roof Framing Using Cold-Formed Steel Members RESEARCH REPORT RP06-2 American Iron and Steel Institute

research report Residential Hip Roof Framing Using Cold-Formed Steel Members RESEARCH REPORT RP06-2 American Iron and Steel Institute research report Residential Hip Roof Framing Using Cold-Formed Steel Members RESEARCH REPORT RP06-2 2006 American Iron and Steel Institute Residential Hip Roof Framing Using Cold-Formed Steel Members i

More information

Sheet metal operations - Bending and related processes

Sheet metal operations - Bending and related processes Sheet metal operations - Bending and related processes R. Chandramouli Associate Dean-Research SASTRA University, Thanjavur-613 401 Table of Contents 1.Quiz-Key... Error! Bookmark not defined. 1.Bending

More information

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs. FRAME PROFILE MASONRY FLUSH MASONRY KD MITER CORNER JOINT Bend Tabs Head #8 Screw (MS002485) Required on all fire rated KD frames Corner Assembly 2" (50.8) Head Jamb Head Break Away Corner Clip Spot Welds

More information

Preformed Metal Roofing and Siding

Preformed Metal Roofing and Siding Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision

More information

Fire Protection. CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8. Floor Assembly No.

Fire Protection. CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8. Floor Assembly No. BULLETIN No. 28 (a) Fire Protection CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8 Floor Assembly No. NRC764-FF22 Fire Endurance Period 1 74 minutes Sound

More information

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety

More information

Technical Notes 3B - Brick Masonry Section Properties May 1993

Technical Notes 3B - Brick Masonry Section Properties May 1993 Technical Notes 3B - Brick Masonry Section Properties May 1993 Abstract: This Technical Notes is a design aid for the Building Code Requirements for Masonry Structures (ACI 530/ASCE 5/TMS 402-92) and Specifications

More information

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC UL 580 TEST REPORT Rendered to: ARMSTRONG WORLD INDUSTRIES SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC Report No.: Test Dates: 12/14/09 Through: 12/22/09 Report Date: 03/12/10 Expiration

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS door frames Engineered product systems INSTALLATION INSTRUCTIONS door frames MINIMALIST DOOR FRAME Fry Reglet Flush Door frames are designed for use with 3 5/8 studs with ½ drywall both sides (4 5/8 throat

More information

SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. This section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,

More information

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,

More information

SECTION 05 42 16 COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

SECTION 05 42 16 COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying cold-formed metal deck framing products and execution. The specifier needs to edit the guide

More information

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading: SEISMIC DESIGN Various building codes consider the following categories for the analysis and design for earthquake loading: 1. Seismic Performance Category (SPC), varies from A to E, depending on how the

More information

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar Problem 1 Design a hand operated overhead crane, which is provided in a shed, whose details are: Capacity of crane = 50 kn Longitudinal spacing of column = 6m Center to center distance of gantry girder

More information

BLIND TEST ON DAMAGE DETECTION OF A STEEL FRAME STRUCTURE

BLIND TEST ON DAMAGE DETECTION OF A STEEL FRAME STRUCTURE BLIND TEST ON DAMAGE DETECTION OF A STEEL FRAME STRUCTURE C.J. Black< 1 >,C.E. Ventura(2) Graduate Student, < 2 > Associate Professor University of British Columbia Department of Civil Engineering

More information

ARCH 331 Structural Glossary S2014abn. Structural Glossary

ARCH 331 Structural Glossary S2014abn. Structural Glossary Structural Glossary Allowable strength: Nominal strength divided by the safety factor. Allowable stress: Allowable strength divided by the appropriate section property, such as section modulus or cross

More information

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year. ICC-ES Evaluation Report ESR-2270 Reissued September, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

PANELIZED HOME INSTALLATION GUIDELINE

PANELIZED HOME INSTALLATION GUIDELINE PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.

More information

Section 5A: Guide to Designing with AAC

Section 5A: Guide to Designing with AAC Section 5A: Guide to Designing with AAC 5A.1 Introduction... 3 5A.3 Hebel Reinforced AAC Panels... 4 5A.4 Hebel AAC Panel Design Properties... 6 5A.5 Hebel AAC Floor and Roof Panel Spans... 6 5A.6 Deflection...

More information

Chapter 6 ROOF-CEILING SYSTEMS

Chapter 6 ROOF-CEILING SYSTEMS Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;

More information

SMALL SCALE ASTM E 119/UL 263 ONE HOUR FIRE TESTING FOR MARINOWARE ON JOIST-RITE WITH ARMOROC FLOOR VTEC #100-2949-1 TESTED: MAY 23, 2008 REVISION

SMALL SCALE ASTM E 119/UL 263 ONE HOUR FIRE TESTING FOR MARINOWARE ON JOIST-RITE WITH ARMOROC FLOOR VTEC #100-2949-1 TESTED: MAY 23, 2008 REVISION SMALL SCALE ASTM E 119/UL 263 ONE HOUR FIRE TESTING FOR MARINOWARE ON JOIST-RITE WITH ARMOROC FLOOR VTEC #100-2949-1 TESTED: MAY 23, 2008 REVISION 2.0: OCTOBER 14, 2008 October 14, 2008 Client: Attn: Subject:

More information

Alternative Steel Materials to BS 5950

Alternative Steel Materials to BS 5950 BC 1: 2008 Design Guide on Use of Alternative Steel Materials to BS 5950 BCA Sustainable Construction Series 3 The education and research arm of the Building and Construction Authority 200 Braddell Road

More information

STRUCTURAL WELDED WIRE REINFORCEMENT

STRUCTURAL WELDED WIRE REINFORCEMENT STRUCTURAL WELDED WIRE REINFORCEMENT 2 1 WIRE REINFORCEMENT INSTITUTE, INC. Excellence Set in Concrete www.wirereinforcementinstitute.org Manual of Standard Practice Structural Welded Wire Reinforcement

More information

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015 0 ICC ES Report ICC ES (800) 42 6587 (562) 699 054 www.icc es.orgg 000 Most Widely Accepted and Trusted ESR 2269 Reissued 02/205 This report is subject to renewal 02/207. DIVISION: 0 00 00 CONCRETE SECTION:

More information

Module 5 (Lectures 17 to 19) MAT FOUNDATIONS

Module 5 (Lectures 17 to 19) MAT FOUNDATIONS Module 5 (Lectures 17 to 19) MAT FOUNDATIONS Topics 17.1 INTRODUCTION Rectangular Combined Footing: Trapezoidal Combined Footings: Cantilever Footing: Mat foundation: 17.2 COMMON TYPES OF MAT FOUNDATIONS

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

EMLA 920 EMLA GUIDE SPECIFICATIONS FOR EXPANDED METAL LATHING AND FURRING -09 NAAMM STANDARD. Fifth Edition NAAMM EMLA 920-09.

EMLA 920 EMLA GUIDE SPECIFICATIONS FOR EXPANDED METAL LATHING AND FURRING -09 NAAMM STANDARD. Fifth Edition NAAMM EMLA 920-09. NAAMM STANDARD EMLA 920-09 LATHING AND FURRING 9 METAL NAAMM EMLA 920-09 December 2009 GUIDE SPECIFICATIONS FOR EXPANDED METAL LATHING AND FURRING Fifth Edition NAAMM EMLA 920-09 December 2009 9 METAL

More information

Steel joists and joist girders are

Steel joists and joist girders are THE STEEL CONFERENCE Hints on Using Joists Efficiently By Tim Holtermann, S.E., P.E.; Drew Potts, P.E.; Bob Sellers, P.E.; and Walt Worthley, P.E. Proper coordination between structural engineers and joist

More information

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia E-mail: info@usgme.com Fax: +966 3 8121029 +966 3 8120995

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia E-mail: info@usgme.com Fax: +966 3 8121029 +966 3 8120995 USG Middle East, Ltd. Dammam, Saudi Arabia E-mail: info@usgme.com Fax: +966 3 8121029 +966 3 8120995 Riyadh, Saudi Arabia E-mail: riyadhsales@usgme.com Fax: +966 1 4772734 +966 1 4772734 Jeddah, Saudi

More information

Featuring TJ Rim Board and TimberStrand LSL

Featuring TJ Rim Board and TimberStrand LSL #TJ-8000 SPECIFIER S GUIDE TRUS JOIST RIM BOARD Featuring TJ Rim Board and TimberStrand LSL Multiple thicknesses, grades, and products to cover all your rim board needs 1¼" Thickness matches lateral load

More information

STANDARD OPEN PATIO COVER

STANDARD OPEN PATIO COVER STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist

More information

Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing

Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing Specifications for SURE-BOARD Series 200 and 200W Panel for shear PART 1.0 GENERAL 1.01

More information

SECTION 15140 - PIPE HANGERS AND SUPPORTS

SECTION 15140 - PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

Cable Trays Technical Instructions & Specifications

Cable Trays Technical Instructions & Specifications Cable Trays Technical Instructions & Specifications Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased

More information

Design Parameters for Steel Special Moment Frame Connections

Design Parameters for Steel Special Moment Frame Connections SEAOC 2011 CONVENTION PROCEEDINGS Design Parameters for Steel Special Moment Frame Connections Scott M. Adan, Ph.D., S.E., SECB, Chair SEAONC Structural Steel Subcommittee Principal Adan Engineering Oakland,

More information

Screw Thread Design. Rev. 3-4-09

Screw Thread Design. Rev. 3-4-09 Screw Thread Design Screw Thread Fundamentals A screw thread is defined as a ridge of uniform section in the form of a helix on either the external or internal surface of a cylinder. Internal threads refer

More information

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For:

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: TEST REPORT Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PRODUCT: Gorilla Column PVC Porch Post System with PVC Base / Cap Plates, PVC Bushings and 2-3/8 in Diameter and 3-1/2 in Diameter Galvanized

More information

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11 K. D. FRAME ASSEMBLY FOR MASONRY WALLS...........................Ins 2 FRAME INSTALLATION DETAILS FOR MASONRY WALLS......................Ins 3 INSTALLING EXISTING MASONRY WALL ANCHORS IN FRAME..................Ins

More information

Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049

Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049 Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal

More information

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.

More information

DENVER MODEL 30 X 30 SPECIFICATIONS

DENVER MODEL 30 X 30 SPECIFICATIONS DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch

More information

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION Generated: Sergiy Papyshev Engineering Approved: Don Prysi Manufacturing Approved: Merzuk Ramic Quality Approved: Steven Barnett Administrative DATE DATE DATE

More information

FRP Grating, Handrail, Guidelines for Ladders & the Engineer Structural and Designer Shapes

FRP Grating, Handrail, Guidelines for Ladders & the Engineer Structural and Designer Shapes Guidelines for the Engineer and Designer FRP Grating, Handrail, Ladders & Structural Shapes Corrosion Resistant Fire Retardant Low Maintenance Long Service Life High Performance Composite Solutions 1.0

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Residential Decks Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information

Design of Cold-Formed Steel Shear Walls

Design of Cold-Formed Steel Shear Walls DESIGN GUIDE 2 Design of Cold-Formed Steel Shear Walls March 1998 The following publication was developed by R.L. Brockenbrough & Associates for the American Iron and Steel Institute (AISI), In the production

More information

2. Design of Welded Connections

2. Design of Welded Connections AWS D1.1:2 2. Design of Welded Connections 2. Scope This section covers the requirements for the design of welded connections. It is divided into four Parts, described as follows: Part A Common Requirements

More information

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical

More information

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia DESIGN OF SLABS Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia Introduction Types of Slab Slabs are plate elements

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

A transverse strip of the deck is assumed to support the truck axle loads. Shear and fatigue of the reinforcement need not be investigated.

A transverse strip of the deck is assumed to support the truck axle loads. Shear and fatigue of the reinforcement need not be investigated. Design Step 4 Design Step 4.1 DECK SLAB DESIGN In addition to designing the deck for dead and live loads at the strength limit state, the AASHTO-LRFD specifications require checking the deck for vehicular

More information

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. www.r-control.com CONTROL, NOT COMPROMISE.

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. www.r-control.com CONTROL, NOT COMPROMISE. R-CONTROL s STRUCTURAL INSULATED PANELS Note: Information deemed reliable at time of printing. Please visit www.r-control.com for latest information. June 2012 CONTROL, NOT COMPROMISE. www.r-control.com

More information

Index 20010 Series Prestressed Florida-I Beams (Rev. 07/12)

Index 20010 Series Prestressed Florida-I Beams (Rev. 07/12) Index 20010 Series Prestressed Florida-I Beams (Rev. 07/12) Design Criteria AASHTO LRFD Bridge Design Specifications, 6th Edition; Structures Detailing Manual (SDM); Structures Design Guidelines (SDG)

More information

5 Steel elements. 5.1 Structural design At present there are two British Standards devoted to the design of strucof tural steel elements:

5 Steel elements. 5.1 Structural design At present there are two British Standards devoted to the design of strucof tural steel elements: 5 Steel elements 5.1 Structural design At present there are two British Standards devoted to the design of strucof steelwork tural steel elements: BS 449 The use of structural steel in building. BS 5950

More information

Compression Members: Structural elements that are subjected to axial compressive forces

Compression Members: Structural elements that are subjected to axial compressive forces CHAPTER 3. COMPRESSION MEMBER DESIGN 3.1 INTRODUCTORY CONCEPTS Compression Members: Structural elements that are subjected to axial compressive forces onl are called columns. Columns are subjected to axial

More information

III. Compression Members. Design of Steel Structures. Introduction. Compression Members (cont.)

III. Compression Members. Design of Steel Structures. Introduction. Compression Members (cont.) ENCE 455 Design of Steel Structures III. Compression Members C. C. Fu, Ph.D., P.E. Civil and Environmental Engineering Department University it of Maryland Compression Members Following subjects are covered:

More information

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010 Best Barns USA Assembly Book Revised November 29, 2010 SAMPLE INSTRUCTIONS the Denver 12'x 12' or 12'x16' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775

More information

HOPLEYS OPENWEBSTEELJOISTS

HOPLEYS OPENWEBSTEELJOISTS Design Aid Manual Now also includes Letter of Certification & Bearer Span Table HOPLEYS OPENWEBSTEELJOISTS 2...has over 60 years experience and a respected reputation in Sheet Metal fabrication and associated

More information

MECHANICS OF SOLIDS - BEAMS TUTORIAL 1 STRESSES IN BEAMS DUE TO BENDING. On completion of this tutorial you should be able to do the following.

MECHANICS OF SOLIDS - BEAMS TUTORIAL 1 STRESSES IN BEAMS DUE TO BENDING. On completion of this tutorial you should be able to do the following. MECHANICS OF SOLIDS - BEAMS TUTOIAL 1 STESSES IN BEAMS DUE TO BENDING This is the first tutorial on bending of beams designed for anyone wishing to study it at a fairly advanced level. You should judge

More information

Sheet Metal Bending. By- Prem Mahendranathan

Sheet Metal Bending. By- Prem Mahendranathan Sheet Metal Bending By- BENDING n Bending is a manufacturing process by which a metal can be deformed by plastically deforming the material and changing its shape n Deformation about one axis PROFILES

More information

City of San Diego, CWP Guidelines

City of San Diego, CWP Guidelines PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,

More information

COLORADO MODEL. 35 x 65 SPECIFICATIONS

COLORADO MODEL. 35 x 65 SPECIFICATIONS COLORADO MODEL 35 x 65 SPECIFICATIONS Dimensions: Roof Dimensions 35-0 x 65-0 Column Dimensions (center to center) 31-0 x 30-6 Minimum Clearance 14-0 Roof Height @ Peak ±18-8 Curved Roof ±42-6 radius Square

More information

INTRODUCTION TO BEAMS

INTRODUCTION TO BEAMS CHAPTER Structural Steel Design LRFD Method INTRODUCTION TO BEAMS Third Edition A. J. Clark School of Engineering Department of Civil and Environmental Engineering Part II Structural Steel Design and Analysis

More information

SECTION 07400 STANDING SEAM METAL ROOF

SECTION 07400 STANDING SEAM METAL ROOF SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and

More information

Overhang Bracket Loading. Deck Issues: Design Perspective

Overhang Bracket Loading. Deck Issues: Design Perspective Deck Issues: Design Perspective Overhang Bracket Loading Deck overhangs and screed rails are generally supported on cantilever brackets during the deck pour These brackets produce an overturning couple

More information

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE SECTION 2.2 PAGE 1 / 9 l DESCRIPTION UCAN TZ torque controlled mechanical expansion wedge anchors have a Category 1 classification. They are used to resist static, wind and seismic tension and shear loads

More information

Joist. Reinforcement. Draft 12/7/02

Joist. Reinforcement. Draft 12/7/02 Joist Reinforcement Draft 12/7/02 1 JOIST REINFORCING The purpose of this CSD Design Aid is to provide procedures and suggested details for the reinforcement of open web steel joists. There are three basic

More information

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation

More information

System. Stability. Security. Integrity. 150 Helical Anchor

System. Stability. Security. Integrity. 150 Helical Anchor Model 150 HELICAL ANCHOR System PN #MBHAT Stability. Security. Integrity. 150 Helical Anchor System About Foundation Supportworks is a network of the most experienced and knowledgeable foundation repair

More information