1 TrueZNE for Hydronic ontrol iring iagrams

2 Honeywell s TrueZNE panels can control zone valves and circulator relays in hydronic heating applications. This document provides helpful wiring diagrams to assist you in a variety of installation scenarios. HZ HZ22 HZ2 Hot ater Zone Valve or irculator elay Panel ontrol TrueZNE HZ22 with Hot ater Zone Valve or irculator elay Panel... Hot ater Zone Valves with / ampers TrueZNE HZ with Hot ater Zone Valves and / ampers... TrueZNE HZ2 with Hot ater Zone Valves and / ampers... Hot ater Zone Valve or irculator elay Panel with / ampers TrueZNE HZ with Hot ater Zone Valve or irculator elay Panel and / ampers...5 TrueZNE HZ22 with Hot ater Zone Valve or irculator elay Panel and / ampers...5 TrueZNE HZ2 with Hot ater Zone Valve or irculator elay Panel and / ampers...5 Hydro-air pplications TrueZNE HZ with Hydro-air pplication...6 TrueZNE HZ22 with Hydro-air pplication...6 2

3 hen used with our edink-enabled TrueZNE panels, our ireless dapter and ireless FocusP Thermostat you can easily and wirelessly add hydronic zoning to a home or add more zones to an existing system. In addition, wireless hydronic zoning introduces the opportunity to increase profit with add-on accessories such as the Portable omfort ontrol and ireless utdoor Sensor for the ultimate in convenience and control. + ireless FocusP Thermostats TrueZNE Panel ireless dapter ireless Zone Valve ontrol ireless TrueZNE HZ22 with Hot ater Zone Valve control...6 ireless TrueZNE HZ2 with Hot ater Zone Valve control...6 ireless irculator ontrol ireless TrueZNE HZ22 with Hot ater irculator control...7 ireless TrueZNE HZ2 with Hot ater irculator control...7 ireless elay Panel ontrol ireless TrueZNE HZ2 with Hot ater elay Panels...7 ptional ireless ccessories TM Portable omfort ontrol ireless utdoor Sensor

4 Hot ater Zone Valve or irculator elay Panel ontrol TrueZNE HZ22 with Hot ater Zone Valve or irculator elay Panel or Z amper T ( ) T ( ) Zone valve or circulator relay panel c h Thermostat MPE THEMSTT HZ22 MPE THEMSTT ire zones -2 the same as zone. 2 volt transformer ooling ompressor elay Fan elay 2 PE H S/K HET HET 2 2 FN PUE EM HET EMEEN HET MPE THEMSTT SENS HZ22 zone panel controlling a zone valve or circulator relay panel. emove the h/c jumper on the equipment terminals of the HZ22 Hot ater Zone Valves with / ampers TrueZNE HZ with Hot ater Zone Valves and / ampers TrueZNE HZ2 with Hot ater Zone Valves and / ampers or Z amper 2 or Z amper 2 volt transformer 2 ooling 2 volt transformer ompressor elay Fan elay MPE THEMSTT PE SENS h c HET FN PUE HZ PUE VEIE MPE THEMSTT MPE THEMSTT h c Thermostat HZ zone panel controlling air-conditioning zoned with dampers and heating zoned with hot water zone valves. 2 volt transformer There are different ways to wire zone valves to the aquastat. For complete wiring instructions on any of the zone valve and aquastat refer to the product data sheets for those controls. Th Tr (ellow wires) V80 zone valve The thermostats used must have separate h andc (or and c) terminals with jumper removed. ire zones 2 and the same as zone. ooling ompressor elay Fan elay 2 2 volt transformer SENSS ESSIES PE THEMSTT Zone MPE H S/K Z Z2 HZ2 HET HET 2 HET 2 PUE FN ZNE EM HET EMEEN HET MPE THEMSTT MPE THEMSTT MPE THEMSTT h c Thermostat (ellow wires) V80 zone valve The thermostats used must have separate h and c (or and c) terminals with jumper removed. * There are different ways to wire zone valves to the aquastat. For complete wiring instructions on any of the zone valve and aquastat refer to the product data sheets for those controls. Th Tr ire zones 2 - the same as zone. F P HME NFI HEK UT JUST SETTIN HZ2 zone panel controlling air-conditioning zoned with dampers and heating zoned with hot water zone valves.

5 Hot ater Zone Valve or irculator elay Panel with / ampers TrueZNE HZ with Hot ater Zone Valve or irculator elay Panel and / ampers TrueZNE HZ22 with Hot ater Zone Valve or irculator elay Panel and / ampers or Z amper or Z amper T ( ) T ( ) quastat Fan relay center 2 volt transformer * SENS PE THEMSTT MPE h c HZ HET FN PUE PUE VEIE THEMSTT THEMSTT MPE MPE h c Thermostat ire zones 2 and the same as zone. Thermostats need to be configured to energize fan in heat. ooling ompressor elay Fan elay 2 volt transformer 2 PE THEMSTT MPE H S/K HZ22 HET HET 2 2 FN PUE EM HET EMEEN HET MPE THEMSTT MPE THEMSTT SENS h c Thermostat T ( ) T ( ) Zone valve or circulator relay panel The thermostats used must have separate h and c (or and c) terminals with jumper removed. ire zones 2 and the same as zone. HZ zone panel controlling a hydro-air application * emove the h/c jumper on the equipment terminals of the HZ HZ22 zone panel controlling air-conditioning zoned with dampers and heating zoned with a zone valve or circulator relay panel. TrueZNE HZ2 with Hot ater Zone Valve or irculator elay Panel and / ampers or Z amper ooling ompressor elay Fan elay 2 volt transformer 2 SENSS ESSIES PE THEMSTT Zone MPE H S/K Z Z2 HZ2 HET HET 2 HET 2 PUE FN ZNE EM HET EMEEN HET MPE THEMSTT MPE THEMSTT MPE THEMSTT h c Thermostat T ( ) T ( ) Zone valve or circulator relay panel The thermostats used must have separate h and c (or and c) terminals with jumper removed. ire zones 2 and the same as zone. F P HME NFI HEK UT JUST SETTIN HZ2 zone panel controlling air-conditioning zoned with dampers and heating zoned with a zone valve or circulator relay panel. 5

6 Hydro-air pplications TrueZNE HZ with Hydro-air pplication TrueZNE HZ22 with Hydro-air pplication or Z amper or Z amper T ( ) T ( ) quastat Fan relay center 2 volt transformer * MPE THEMSTT PE SENS h c HET FN PUE HZ PUE VEIE THEMSTT THEMSTT MPE MPE HZ zone panel controlling a hydro-air application * emove the h/c jumper on the equipment terminals of the HZ h c Thermostat ire zones 2 and the same as zone. Thermostats need to be configured to energize fan in heat. T ( ) T ( ) quastat Fan relay center 2 * PE THEMSTT MPE H S/K HZ22 HET HET 2 2 FN PUE EM HET EMEEN HET MPE THEMSTT MPE THEMSTT SENS h c Thermostat ire zones 2- the same as zone. Zone panel needs to be configured to energize fan in heat HZ22 zone panel controlling a hydro-air application. * emove the h/c jumper on the equipment terminals of the HZ22 ireless Zone Valve ontrol ireless TrueZNE HZ22 with Hot ater Zone Valve control ireless TrueZNE HZ2 with Hot ater Zone Valve control utdoor 6 TH000 TH T V80 zone valve (or equivalent) ireless adaptor* MPE THEMSTT PE IEESS H S/K HET HET 2 2 FN PUE EM HET HZ22 EMEEN HET IEESS HME NFI HEK UT ME K JUST SETTIN NEXT MPE THEMSTT MPE THEMSTT SENS TH T TH T emove the h/c jumper at the panel. If the Honeywell valve has yellow and red wires instead of terminal connections, the red wires are the end switch, the yellow wires are the TH and T. ire the end switch from each valve in parallel to the and or T and T at the aquastat or boiler. If cooling is zoned, the dampers (not shown), are wired as normal to the TrueZNE panel. T() T() quastat utdoor TH000 TH T V80 zone valve (or equivalent) ireless adaptor* Zone MPE THEMSTT PE ESSIES SENSS IEESS H S/K E Z Z2 HET HET 2 HET 2 PUE FN EM HET HZ2 ZNE EMEEN HET HME NFI HEK UT JUST SETTIN MPE THEMSTT MPE THEMSTT MPE THEMSTT TH T TH T TH T emove the h/c jumper at the panel. If the Honeywell valve has yellow and red wires instead of terminal connections, the red wires are the end switch, the yellow wires are the TH and T. ire the end switch from each valve in parallel to the and or T and T at the aquastat or boiler. If cooling is zoned, the dampers (not shown), are wired as normal to the TrueZNE panel. E hen a TH000 is used you cannot expand beyond zones. T() T() quastat

7 TM ireless irculator ontrol ireless TrueZNE HZ22 with Hot ater irculator control ireless TrueZNE HZ2 with Hot ater irculator control irculator ine Voltage power T() T() quastat utdoor 6 2 TH000 ireless adaptor* MPE THEMSTT PE IEESS H S/K HET HET 2 2 FN PUE EM HET HZ22 EMEEN HET IEESS HME NFI HEK UT ireless elay Panel ontrol ME K JUST SETTIN NEXT MPE THEMSTT MPE THEMSTT SENS E E emove the h/c jumper at the panel. It is up to the installing contractor to determine what voltage is required to power the transformer primary and circulators. If cooling is zoned, the dampers (not shown), are wired as normal to the TrueZNE panel. ire the and from each relay in parallel to the T and T (or and ) terminals at the boiler or aquastat. E Each circulator circuit would be wired to the corresponding zone s relay. This circuit is shown on zone of this diagram. irculator ine Voltage power T() T() quastat utdoor TH000 2 ireless adaptor* Zone MPE THEMSTT PE ESSIES SENSS IEESS H S/K F Z Z2 HET HET 2 HET 2 PUE FN EM HET HZ2 ZNE EMEEN HET HME NFI HEK UT JUST SETTIN MPE THEMSTT MPE THEMSTT MPE THEMSTT 6 6 E E 6 E emove the h/c jumper at the panel. It is up to the installing contractor to determine what voltage is required to power the transformer primary and circulators. If cooling is zoned, the dampers (not shown), are wired as normal to the TrueZNE panel. ire the and from each relay in parallel to the T and T (or and ) terminals at the boiler or aquastat. E Each circulator circuit would be wired to the corresponding zone s relay. This circuit is shown on zone of this diagram. F hen a TH000 is used you cannot expand beyond zones. ireless ireless HZ2 TrueZNE zone panel HZ2 controlling with Hot ater a hot elay water Panelsrelay panel. Parts needed for wireless installation: T() T() utdoor ine Voltage power Zone of relay panel TH000 2 SENSS ESSIES PE THEMSTT Zone MPE IEESS H S/K F Z Z2 HZ2 HET HET 2 HET 2 PUE FN ZNE EM HET EMEEN HET HME NFI HEK UT MPE THEMSTT MPE THEMSTT MPE THEMSTT T() T() of relay panel of relay panel T() T() T() T() of relay panel ireless Zoning daptor Kit: ou would need of these per zone panel Programmable ireless Zoning daptor Kit (TH62002) *ireless daptor (TH000): onnects to your choice of wireless thermostats Programmable ireless FocusP (TH62000) Verify the TrueZNE box has a edink sticker on it. Non-Programmable ireless Zoning daptor Kit (TH520025) Non-Programmable ireless FocusP (TH520002) ireless adaptor* JUST SETTIN ptional ireless ccessories: emove the h/c jumper at the panel. It is up emove to the installing the h/c contractor jumper to determine at the panel. what voltage is required to power the transformer primary and circulators. If cooling It is is zoned, up to the the dampers installing (not contractor shown), are to wired determine as normal what to the voltage Truezone is panel. required to power the transformer primary and circulators. hen a TH000 is used you cannot expand beyond zones. If cooling is zoned, the dampers (not shown), are wired as normal to the TrueZNE panel. hen a TH000 is used you cannot expand beyond zones. Parts needed:. ireless Truezone panels: (Verify the box has a edlink sticker on it) HZ2K - -zones, heat/2 cool. 2. ireless thermostats with adaptor for zone : ption : TH62002 is a kit that includes a TH620 wireless programmable thermostat, and TH wireless adaptor. ou would need of these per zone panel. ption 2: TH is a kit that includes a TH520 wireless non-programmable thermostat, and TH wireless adaptor. ou would need of these per zone panel. Portable omfort ontrol (EM500000) ireless utdoor Sensor (70890) 7

8 Illustrated in this paper are the most common wiring diagrams for hydronic application of the TrueZNE control panel. It is the contractor's choice on what options make most sense for their business and customer. ith the introduction of wireless hydronic zoning, this document will help create new installation solutions, as well as opportunity to earn more profit with add-on wireless accessories. For questions, please contact the Honeywell Zoning Hotline toll-free at utomation and ontrol Solutions In the US: Honeywell 985 ouglas rive North olden Valley, MN In anada: Honeywell imited 5 ynamic rive Toronto, ntario V Z9 customer.honeywell.com P February Honeywell International Inc.

Installation Guide. Prestige IAQ with Equipment Interface Module. RedLINK to Equipment Interface Module. RedLINK to TrueZONE Wireless Adapter

Installation Guide. Prestige IAQ with Equipment Interface Module. RedLINK to Equipment Interface Module. RedLINK to TrueZONE Wireless Adapter TM TM TM Prestige IAQ with Equipment Interface Module Installation Guide edlink to Equipment Interface Module 2 Wires for Power O edlink to TrueZONE Wireless Adapter 2 Wires for Power eference to key features

More information

Emergency Heat slide switch on the panel or an external switch. Do not use the panel switch or the external switch if Dip switch #4 is set to HP.

Emergency Heat slide switch on the panel or an external switch. Do not use the panel switch or the external switch if Dip switch #4 is set to HP. Installation Instructions The ED4 is a 4-zone panel that can control gas/ electric, hydronic, electric and both conventional and dual fuel heat pumps with multi-stage heating and cooling. Low cost heat-cool

More information

Wireless and Prestige Comfort Systems. Frequently Asked Questions Guide

Wireless and Prestige Comfort Systems. Frequently Asked Questions Guide Wireless and Prestige Comfort Systems Frequently sked uestions Guide TM RedLINK Wireless Technology TM The Description What is RedLINK? RedLINK is the first wireless protocol developed specifically for

More information

How To Set Up A Furnace Pump

How To Set Up A Furnace Pump ork etail System Specific iring Diagrams January 2012 Using Honeywell hermostats Index for Low Voltage iring Affinity Units utdoor Indoor System Description Page ZH 2 Stage HP AV or MV Variable Speed Air

More information

RESIDENTIAL THERMOSTATS CLIMATEMASTER

RESIDENTIAL THERMOSTATS CLIMATEMASTER ESIDENTIAL THEMSTATS LIMATEMASTE ETHEMAL HEATIN AND LIN MFT SYSTEMS ESIDENTIAL THEMSTAT PDUT UIDE THE LBAL LEADE esidential Thermostats 3.30 in [83.8mm] Fan: turns continuous fan FF or N 0.8 in Depth

More information

Install Guide 3M-50. Caution. Caution

Install Guide 3M-50. Caution. Caution PG 1 Install Guide 3M-50 aution Your thermostat is a precise instrument, handle it with care. Turn off electricity to the HVA system before installing or servicing thermostat or any part of the system.

More information

Boiler Applications Drawings

Boiler Applications Drawings Boiler pplications Drawings 800000026 Rev D Contents Drawing No. Boiler Model Description Information... Q & E Series Boilers... EV-10-0001 Rev B... Q & E Series Boilers... Boiler Flat Roof Multiple Termination

More information

LOW VOLTAGE CONTROL CIRCUIT WIRING

LOW VOLTAGE CONTROL CIRCUIT WIRING INSTLLTION INSTUTIONS LOW VOLTE ONTOL IUIT WIIN W** W***D W*S* MODELS W**L WL*S* Bard Manufacturing ompany, Inc. Bryan, Ohio 506 Since 9...Moving ahead just as planned. Manual : 00-507K Supersedes: 00-507J

More information

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types Installation Guide VisionPRO TH8000 Series Touch-screen Programmable Thermostat This manual covers the following models TH8110U: For 1 Heat/1 Cool systems TH8320U: For up to 3 Heat/2 Cool systems TH8321U:

More information

GENERAL SUPPLEMENT 410. Radiantec CONTROLS FOR RADIANT HEATING CONTROLS PURPOSE OF RADIANTEC CONTROLS

GENERAL SUPPLEMENT 410. Radiantec CONTROLS FOR RADIANT HEATING CONTROLS PURPOSE OF RADIANTEC CONTROLS Radiantec ONTROLS FOR RADIANT HEATING GENERAL SUPPLEMENT 410 ONTROLS This supplement presents a layman s language narrative about Radiantec ompany controls, their design and their installation. This supplement

More information

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Chapter 5 Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Objectives Upon completion of this course, you will be able to: Explain what electrical loads are and their general purpose

More information

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved.

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved. Sensi TM Wi-Fi Programmable Thermostat MANUAL OPERATION Version: March 2016 2016 Emerson Electric Co. All rights reserved. Contents MANUAL OPERATION GUIDE Buttons and Icons 3 Basic Functionality 4 Manual

More information

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace) UNIT OBJECTIVES Describe the concept of year-round air conditioning List three typical year-round air conditioning system types List the five ways to condition the air Determine airflow for a cooling system

More information

T8000, T8001 Programmable Thermostat

T8000, T8001 Programmable Thermostat T8000, T800 Programmable Thermostat INSTALLATIN INSTUTINS APPLIATIN The T8000, T800 Thermostats provide single-stage, programmable temperature control for 4 Vac heatingcooling systems with manual changeover

More information

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES. QUIET-ONE Environmental Products 2000 Kickspace Heater Series Models: KS 2004, KS 2006 KS 2008, KS 2010 INSTALLATION OPERATING MAINTENANCE Please read these instructions thoroughly before beginning your

More information

Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.

Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E. Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E. Basic Thermostat Types Many technicians have great difficulty understanding how to properly wire a thermostat or how to replace a thermostat with

More information

Y8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control

Y8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control Y850 Fresh Air Ventilation System, 850 Fresh Air Ventilation ontrol PODUT DATA FEATUES APPLIATION The Y850 Fresh Air Ventilation System, 850 Fresh Air Ventilation ontrol provide fresh air to a home. The

More information

Wireless Solutions. Application Selection Guide

Wireless Solutions. Application Selection Guide Wireless Solutions Application Selection Guide THERMOSTATS ZONING AIR CLEANERS HUMIDIFIERS DEHUMIDIFIERS UV SYSTEMS VENTILATION WATER SOLUTIONS COMBUSTION RedLINK Wireless Systems TrueZONE Panel Return

More information

THX9321 Prestige 2.0 THX9421 Prestige IAQ 2.0 with EIM

THX9321 Prestige 2.0 THX9421 Prestige IAQ 2.0 with EIM TM System Installation Guide THX9 Prestige.0 THX94 Prestige IAQ.0 with EIM With wireless accessories ontrol for up to 4 Heat/ ool heat pump systems or up to Heat/ ool conventional systems for residential

More information

Installation Instructions

Installation Instructions Installation Instructions Model TSTATG2111 Use with most systems: 2-Heat, 1-ool 1- Day Prog ram m ab l e Digital Thermostat u p t o 2 - H e a t & 1 - o o l ontrol up to 2 Heat & 1 ool Stages Backlit Display

More information

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge

More information

INSTALLATION REMOVE OLD THERMOSTAT ATTACH THERMOSTAT BASE TO WALL CHECK THERMOSTAT OPERATION BATTERY LOCATION

INSTALLATION REMOVE OLD THERMOSTAT ATTACH THERMOSTAT BASE TO WALL CHECK THERMOSTAT OPERATION BATTERY LOCATION HITE-RDERS 1F86-244 Non-Programmable Electronic Digital Thermostat INSTALLATIN AND PERATIN INSTRUCTINS perator: Save these instructions for future use! FAILURE T READ AND FLL ALL INSTRUCTINS CAREFULL EFRE

More information

RedLINK Wireless Comfort Systems. RedLINK Connects.

RedLINK Wireless Comfort Systems. RedLINK Connects. RedLINK Wireless Comfort Systems RedLINK Connects. TM THERMOSTATS ZONING AIR CLEANERS HUMIDIFIERS DEHUMIDIFIERS UV SYSTEMS VENTILATION WATER SOLUTIONS wireless TM Your Customers Are Connected. Wireless.

More information

Control for up to 4 Heat/2 Cool heat pump systems or up to 3 Heat/2 Cool conventional systems for residential and commercial applications.

Control for up to 4 Heat/2 Cool heat pump systems or up to 3 Heat/2 Cool conventional systems for residential and commercial applications. THX9/94 Prestige IAQ and F EIM With wireless accessories System Installation Guide ontrol for up to 4 Heat/ ool heat pump systems or up to Heat/ ool conventional systems for residential and commercial

More information

Installer Guide smart connect

Installer Guide smart connect Installer Guide smart connect TM 7330 Wireless Remote Humidity Sensor Please read all instructions before proceeding. The wireless remote humidity sensor monitors the humidity passing through the return

More information

Commercial Refrigeration Temperature and Defrost Controls

Commercial Refrigeration Temperature and Defrost Controls Commercial Refrigeration Temperature and Defrost Controls UNI-LINE PRODUCT KNOWLEDGE 2010 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys

More information

T7079A,B Solid State Remote Temperature Controllers

T7079A,B Solid State Remote Temperature Controllers T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature

More information

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work. Install Guide CT100 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the

More information

Installation Questions

Installation Questions Installation Questions How do I determine what type of heat I have? There may be several ways to determine what type of heat you have. First, if you can access the unit that is responsible for creating

More information

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+)

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+) Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+) 1. In addition to the information scheduled below, the pre-tender designer is responsible for: (i)

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

Install Guide CT101. Caution. Caution

Install Guide CT101. Caution. Caution Install Guide CT101 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

Safety & Installation Instructions

Safety & Installation Instructions Home omfort ontrol Model 8910 READ AND SAVE THESE INSTRUTIS Safety & Installation Instructions Table of contents Installation Thermostat installation location recommendations.. 2 Thermostat mounting...

More information

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual PART 8: FIELD WIRING A. INSTALLATION MUST COMPLY WITH: 1. National Electrical Code and any other national, state, provincial or local codes or regulations. 2. In Canada, CSA C22.1 Canadian Electrical Code

More information

Zoning Reference Guide

Zoning Reference Guide Zoning Reference Guide Part No. RG-0508-001 Table of Contents Introduction 1 Braeburn Zone Systems: Comfort on Demand 1 What is a Zoning System? 2 The Braeburn Advantage 4 The Best Value in Zoning Today

More information

Electrical Circuits... 2. Types of Electrical Switches... 3. Switch Operation... 4. Standard Combinations... 6

Electrical Circuits... 2. Types of Electrical Switches... 3. Switch Operation... 4. Standard Combinations... 6 TEIAL AD GEERAL IFORMATIO BASI WIRIG LIK O DESIRED PAGE Electrical ircuits........................................................................... 2 Types of Electrical Switches..................................................................

More information

BASIC WIRING Electrical Circuits...141. Types of Electrical Switches...142. Switch Operation...143. Standard Combinations...144

BASIC WIRING Electrical Circuits...141. Types of Electrical Switches...142. Switch Operation...143. Standard Combinations...144 TEIAL AD GEERAL IFORMATIO ontents BASI WIRIG Electrical ircuits...........................................................................141 Types of Electrical Switches..................................................................142

More information

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types Installation Guide LR-HWLV-HVAC TouchPRO Wireless Touchscreen Thermostat System Types Gas, oil, or electric heat with air conditioning Warm air, hot water, high efficiency furnaces, heat pumps, steam,

More information

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Document updates: Version Data Description V1.0 2015.05.25 Finish new document HVAC Controller User Manual INDEX 1. Overview...1

More information

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7 FAQs Conserve package Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7 FAQs Gateway Can I have someone install my system for me? If you are concerned

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL RCS MODEL ZC4 4 ZONE HVAC INSTALLATION AND OPERATION MANUAL DCN: 141-0020-02 /0/03 INTRODUCTION The 4 Zone HVAC Controller series allows up to 4 standard electronic thermostats to independently control

More information

Fundamentals of HVAC Control Systems

Fundamentals of HVAC Control Systems ASHRAE Hong Kong Chapter Technical Workshop Fundamentals of HVAC Control Systems 18, 19, 25, 26 April 2007 2007 ASHRAE Hong Kong Chapter Slide 1 Chapter 5 Control Diagrams and Sequences 2007 ASHRAE Hong

More information

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

ELECTRIC POSITION for electric heat, then confirm with Fan Test below. Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please

More information

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R. www.heating.danfoss.com

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R. www.heating.danfoss.com MAKING MODERN LIVING POSSIBLE Wiring Diagram www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

General Information. Do programmable thermostats really save energy?

General Information. Do programmable thermostats really save energy? General Information Do programmable thermostats really save energy? Yes, programmable thermostats can save energy which in turn saves you money on your utility bill. The US Department of Energy states

More information

Fully Pumped Systems

Fully Pumped Systems Fully Pumped Systems (also see the picture gallery and System Basics) The term for any boiler that uses a pump to move all the heat from the boiler to every part of the system is fully pumped. As a rule

More information

Installation Guide. Programmable Thermostat TH6220D

Installation Guide. Programmable Thermostat TH6220D Installation Guide Programmable Thermostat TH6220D Product Application This thermostat provides electronic control of 24 VAC single-stage and multi-stage heating and cooling systems, or 750 mv heating

More information

Heating and Hot Water Services Controls General Technical Specification

Heating and Hot Water Services Controls General Technical Specification Construction Services Heating and Hot Water Services Controls General Technical Specification Version 1.0 Environment Heating and Hot Water Services Controls General Technical Specification Contents 1.

More information

Heating and Cooling Basics Thermostat Control

Heating and Cooling Basics Thermostat Control Heating and Cooling Basics Thermostat Control UNI-LINE PRODUCT KNOWLEDGE 2012 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys are proprietary

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2008-36 TSG-PRESTIGE Date revised: 12/6/10

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2008-36 TSG-PRESTIGE Date revised: 12/6/10 prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 12/6/10 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1-2 SERVICING TIPS AND INSTRUCTIONS Page 3-4

More information

1F78 CAUTION CONTENTS YOUR THERMOSTAT REPLACES PREPARATIONS. Installation Instructions for. Heating & Air Conditioning. Non-Programmable Thermostat

1F78 CAUTION CONTENTS YOUR THERMOSTAT REPLACES PREPARATIONS. Installation Instructions for. Heating & Air Conditioning. Non-Programmable Thermostat CNTENTS Installation Instructions for Heating & Air Conditioning 1F78 n-programmable Thermostat Preparations... 1 Thermostat Details... 1 Removing ld Thermostat... 1 Mounting and iring... 2 Check Thermostat

More information

Name: Air Conditioning, Heating and Refrigeration (47.0201)

Name: Air Conditioning, Heating and Refrigeration (47.0201) Name: Air Conditioning, Heating and Refrigeration (47.0201) Directions: Evaluate the student by entering the appropriate number to indicate the degree of competency. Rating Scale (0-6): 0 No Exposure no

More information

T841A Heating-Cooling Heat Pump Thermostat

T841A Heating-Cooling Heat Pump Thermostat T84A Heating-Cooling Heat Pump Thermostat APPLICATIN The T84A Heating-Cooling TADELINE Thermostat provides 4 Vac control of two-stage heating and onestage cooling in heat pump systems, using manual changeover.

More information

http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html

http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html APPLY POWER TO APPLIANCE FIELD WIRING CORRECT? DPLAY ERROR CODE 1 OR 2 Intelli-Vent TM Sequence of Operation REQUEST FOR HEAT PRESENT?

More information

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00 RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls

More information

Nest Learning Thermostat Installation Guide. Installation step-by-step

Nest Learning Thermostat Installation Guide. Installation step-by-step Nest Learning Thermostat Installation Guide Installation step-by-step Contents Compatibility. 3 In the box. 4 Before you start. 5 Choose an installation method. 6 Replacing an existing wired thermostat.

More information

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface

More information

Resistors in Series and Parallel Circuits

Resistors in Series and Parallel Circuits 69 Resistors in Series and Parallel Circuits E&M: Series and parallel circuits Equipment List DataStudio file: Not Required Qty s Part Numbers 1 C/DC Electronics Lab EM-8656 2 D cell 1.5 volt Introduction

More information

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB

More information

Student Exploration: Circuits

Student Exploration: Circuits Name: Date: Student Exploration: Circuits Vocabulary: ammeter, circuit, current, ohmmeter, Ohm s law, parallel circuit, resistance, resistor, series circuit, voltage Prior Knowledge Questions (Do these

More information

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled

More information

HEAT HEAT COOL HEAT PUMP COOL

HEAT HEAT COOL HEAT PUMP COOL OWNER S MANUAL RESIDENTIAL THERMOSTAT P/N P374-1800 HEAT COOL HEAT PUMP Su AUTO 0I20: Pm 74 COOL HEAT 27 7-DAY MABLE DIGITAL THERMOSTAT 3 Configurable Outputs Accepts Optional Humidity Module: Control

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION The purpose of this guide specification is to assist the specifier in correctly specifying Mechanical System Testing

More information

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting. Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please

More information

June 27, 2009. Dear Customer,

June 27, 2009. Dear Customer, June 27, 2009 Dear Customer, We are pleased to announce new products and sales tools to help you have even more success with the Pro1 line of professional heating and cooling products. Please review the

More information

www.the Floor Heating Warehouse.co.uk

www.the Floor Heating Warehouse.co.uk www.the Floor Heating Warehouse.co.uk Underfloor Heating Installation Guide (Grundfoss Pump System) General Overview: Our water based underfloor heating system can be installed by your own plumber or heating

More information

B. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems.

B. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems. SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes wall switches; wall dimmers; receptacles; multioutlet assembly; and device plates and decorative box covers. B. Related

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to

More information

Guidance on how to comply with the 2013 Building Regulations Part L

Guidance on how to comply with the 2013 Building Regulations Part L Guidance on how to comply with the 2013 Building Regulations Part L Version 1.0 6 April 2014 This guide supports the official guidance covering the control of gas and oil fired wet central heating installations

More information

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units S & P COI PRODUCTS TD SPC HOUSE, EVIGTO VAEY ROAD, EICESTER. E5 5U Guidance Document Electrical layouts for EC Motors in Fan Convector units Hasnain Merchant Richard Meskimmon 4/9/0 This document is intended

More information

Digi-Motor Installation Guide

Digi-Motor Installation Guide Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support

More information

QPCD100-2500. QPCD-100 Parts List 115 Volt / 1 Phase / 60 Hz / R-134A REFRIGERANT COMPRESSOR, 0.75HP, R-134A DRAIN VALVE, 2-WAY SOLENOID VALVE, 0.

QPCD100-2500. QPCD-100 Parts List 115 Volt / 1 Phase / 60 Hz / R-134A REFRIGERANT COMPRESSOR, 0.75HP, R-134A DRAIN VALVE, 2-WAY SOLENOID VALVE, 0. QPCD100-2500 QPCD-100 Parts List 115 Volt / 1 Phase / 60 Hz / R-134A, 0.75HP, R-134A HOT GAS BYPASS VALVE THERMOSTAT RELAY DRAIN VALVE, 2-WAY SOLENOID VALVE, 0.375" DRAIN TIMER Y-STRAINER SCREEN QRF-003109

More information

What is a multimeter?

What is a multimeter? What is a multimeter? A multimeter is a devise used to measure voltage, resistance and current in electronics & electrical equipment It is also used to test continuity between to 2 points to verify if

More information

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage

More information

QUICK INSTALLATION GUIDE

QUICK INSTALLATION GUIDE QUICK INSTALLATION GUIDE Read Installer Notes before removing cover from Thermostat. 1F85RF-275 Wireless Remote Kit INSTALLER NOTES IMPORTANT Do not apply power to the thermostat or wireless sensor until

More information

WHITE-RODGERS COMFORT-SET 90 SERIES

WHITE-RODGERS COMFORT-SET 90 SERIES INSTALLATI DESCRIPTI WHITE-RODGERS COMFORT-SET 90 SERIES MULTI-STAGE INSTALLATI/CFIGURATI This White-Rodgers Automatic Setback Digital Thermostat uses microcomputer technology to provide precise time and

More information

Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats

Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats Communicating Thermostats Add More Flexibility to Building Automation with New Communicating Thermostats More Choices. More Possibilities. From zone control to rooftop units and nearly everything in between,

More information

COMMISSIONING OF HVAC SYSTEMS

COMMISSIONING OF HVAC SYSTEMS FORM CL-01 SYSTEMS / EQUIPMENT INCLUDED : SYSTEM STARTUP CHECKLIST I - PRE - STARTUP INSPECTION EQUIPMENT MOUNTING & SETTING CONTROL, INTERLOCK & POWER WIRING ALIGNMENT OF MOTORS & DRIVES PIPING, CONNECTIONS

More information

Installation and Operation Instructions

Installation and Operation Instructions ENLOSE MNGEMENT GN m VLT GN m VLT Installation and Operation Instructions ONENSING and NON-ONENSING HYRI ONTROL Now with Optional net MS/TP OUTPUT RTINGS: 120V, 6 RESISTIVE 1 PILOT UTY, 15 TOTL FOR LL

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! HITE-RDERS 1F80-51 Programmable Electronic Digital Thermostat INSTALLATIN AND PERATIN INSTRUCTINS perator: Save these instructions for future use! FAILURE T READ AND FLL ALL INSTRUCTINS CAREFULL EFRE INSTALLIN

More information

RVR Hybrid System Installer Instructions - 10052012. RVR Hybrid System Controller Installation Instructions

RVR Hybrid System Installer Instructions - 10052012. RVR Hybrid System Controller Installation Instructions RVR Hybrid System Controller Installation Instructions 1 Introduction to Hybrid Systems The RVR Hybrid system uses a combination of the Immergas Audax range of heat pumps with gas or oil boilers to create

More information

Fossil fuel heating equipment

Fossil fuel heating equipment Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 36C01 Combination Gas Valves (24 Volt and 120 Volt Models) INSTALLATI INSTRUCTIS FAILURE TO READ AND FOLLOW ALL INSTRUCTIS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CTROL COULD CAUSE

More information

Laddomat 21. For accumulation when using a wood-fired boiler. Picture 1. The wood-fired boiler is is connected to to. accumulator tank with bypass

Laddomat 21. For accumulation when using a wood-fired boiler. Picture 1. The wood-fired boiler is is connected to to. accumulator tank with bypass Picture 1 For accumulation when using a wood-fired boiler The wood-fired boiler is is connected to to an accumulator tank with bypass and dwh with......... Laddomat 21 and this is is how it it works...

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

www.inspection-for-industry.com

www.inspection-for-industry.com Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.

More information

HCE80/HCC80/HCE80R/HCC80R

HCE80/HCC80/HCE80R/HCC80R HCE80/HCC80/HCE80R/HCC80R UNDERFLOOR HEATING-ZONEING CONTROLLERS PRODUCT DATA FEATURES Easy and fast installation because the new wiring design Pluggable terminals for fast wiring connection because clamp

More information

Integrated Metering Systems, Inc.

Integrated Metering Systems, Inc. Integrated Metering Systems, Inc. EM Pro Energy Allocation System Product Guide Technical Specifications PN: 114-000X Revision 0.7 List of Figures... 2 List of Tables... 2 1. Product Description... 3 1.1

More information

http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html

http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html TECHNICAL SERVICE DEPARTMENT Effective October 2007, we transitioned to the White Rodgers (Intelli-Vent TM )Thermostat Control for

More information

INSTALLATION MANUAL RS4220 RS5220 RS6220 RS4110 RS5110 RS6110

INSTALLATION MANUAL RS4220 RS5220 RS6220 RS4110 RS5110 RS6110 RS4110 RS5110 RS4220 RS5220 RS6220 INSTAATIN MANUA 352-00060-001 Rev. A RS4000 Series RS5000 Series RS6000 Series Thank you for purchasing a Robertshaw thermostat. This manual will describe how to install

More information

PLP - TERMS AND CONDITIONS

PLP - TERMS AND CONDITIONS PLP - TERMS AND CONDITIONS 2014-2015 Philadelphia Gas Works Residential Parts & Labor Plan Contract This Residential Parts & Labor Plan Contract (this Plan ) is available to customers of the Philadelphia

More information

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODEL CHCRV-5 For Use with Bard CH Series 3, 4 & 5 Ton 2-Stage Wall Mount Heat Pumps AND W38H, W43H, W49H and W61H Single Stage Wall Mount

More information

Gas Valve Proving System

Gas Valve Proving System Gas alve Proving System GY DU... Series... SO 001 The DU... gas valve proving system is designed for use in gas-fired plant equipped with two safety shutoff valves. During each startup cycle, the control

More information

CAUTION: IMPORTANT WARNING: USER S INFORMATION / INSTALLATION INSTRUCTIONS OUTDOOR SPLIT SYSTEM HEAT PUMP TWO - STAGE R-410A 16 SEER MODELS

CAUTION: IMPORTANT WARNING: USER S INFORMATION / INSTALLATION INSTRUCTIONS OUTDOOR SPLIT SYSTEM HEAT PUMP TWO - STAGE R-410A 16 SEER MODELS D PIT TEM EAT PUMP UE INFMATIN / INTAATIN INTUTIN TW - TAGE -410A 16 EE MDE AB TE EAT PUMP our heat pump is a unique, all weather comfort-control appliance that will heat and cool your home year round

More information

WWZ High efficiency HYBRID heat pumps with E.V.I compressor in two sections

WWZ High efficiency HYBRID heat pumps with E.V.I compressor in two sections High efficiency HYRID heat pumps with E.V.I compressor in two sections infolinia: +48 691 262 691-20 +43 +65 E.V.I..O.P. 4,1 The series of high efficiency hybrid heat pumps has been specifically designed

More information

Why and How we Use Capacity Control

Why and How we Use Capacity Control Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,

More information