RESIDENTIAL THERMOSTATS CLIMATEMASTER

Size: px
Start display at page:

Download "RESIDENTIAL THERMOSTATS CLIMATEMASTER"

Transcription

1 ESIDENTIAL THEMSTATS LIMATEMASTE ETHEMAL HEATIN AND LIN MFT SYSTEMS ESIDENTIAL THEMSTAT PDUT UIDE THE LBAL LEADE

2

3 esidential Thermostats 3.30 in [83.8mm] Fan: turns continuous fan FF or N 0.8 in Depth [20.3mm] Mounting: 4.55 in [115.6mm] Mode: Selects system mode - FF, HEAT, L, or EMHEAT 1.587in (40.3mm) Fault Light UP 2.375in (60.3mm) Temperature increase Temperature decrease ATM21U01 Two Heat / ne ool Manual hangeover Non-Programmable Features (cont.): Setup feature allows either current room temp or the current setpoint to be displayed. ptional safety setpoints ensure that heating and cooling will occur even if thermostat is in ff mode. Backplate wiring for easy installation. Specifications: Electrical ating: Input Power: 18 to 30 Vac, 50/60 Hz. Temperature Settings: Setpoint ange: 50 F to 90 F [10 to 32 ]. The default setpoint for heating is 70 F [21 ] and for cooling is 74 F [23 ]. Press the or keys to change the setting. To change between heat and cool settings, press the mode key until the setting to be changed appears. Display ange: Display Updates: ontrolled: updated every 12 seconds. Differential (autochangeover model): 3 F [1.5 ] minimum. utput atings: Maximum current for each output is 1 Amp in (66.7mm) 3.275in (83.2mm) iring: onnection to XM ontrol ATM21U01 Thermostat XM Application: The ATM21U01 electronic thermostat provides two-stage heat, one-stage cool, non-programmable temperature control for 24V water-source heat pump systems. Features: Heat-ff-ool-Em Heat System selections. Fan-n-Auto selections. F or temperature display. Manual changeover operation. Light emitting diode (LED) for alarm status. Installer setup options allow for customized applications. Zero temperature droop performance. Temperature display adjustment feature provides display offset for custom applications. Setpoints are permanently held in memory (no batteries used) and retained during power outages. Extended fan operation feature can be used to operate fan for 90 seconds after Y turns off. ompressor Heating Stage 2 eversing Valve Fan 24Vac Hot 24Vac ommon Fault LED Y / L Y limatemaster esidential Thermostats - ev.: 02/13/06 3

4 limatemaster Fan: turns continuous fan FF or N 4.55 in [115.6mm] Fault Light Temperature: increase ATA22U01 Two Heat / Two ool or Two Heat / ne ool (hen used with auxiliary electric heat) Auto / Manual hangeover Non-Programmable 3.30 in [83.8mm] Temperature: decrease Features (cont.): Setup feature allows either current room temp or the current setpoint to be displayed. ptional safety setpoints ensure that heating and cooling will occur even if thermostat is in ff mode. Backplate wiring for easy installation. 0.8 in Depth [20.3mm] Mode: Selects system mode - FF, HEAT, L, EMHEAT, or AUT Specifications: Electrical ating: Input Power: 18 to 30 Vac, 50/60 Hz. Mounting: 1.587in (40.3mm) 2.375in (60.3mm) Temperature Settings: Setpoint ange: 50 F to 90 F [10 to 32 ]. The default setpoint for heating is 70 F [21 ] and for cooling is 74 F [23 ]. Press the or keys to change the setting. To change between heat and cool settings, press the mode key until the setting to be changed appears. UP Display ange: Display Updates: ontrolled: updated every 12 seconds. Differential (autochangeover model): 3 F [1.5 ] minimum. Application: The ATA22U01 electronic thermostat provides two-stage, nonprogrammable temperature control for 24V water-source heat pump systems. Features: 2.625in (66.7mm) 3.275in (83.2mm) Heat-ff-ool-Em Heat-Auto System selections. Fan-n-Auto selections. F or temperature display. onfi gurable automatic or manual changeover operation. Light emitting diode (LED) for alarm status. Installer setup options allow for customized applications. Zero temperature droop performance. Temperature display adjustment feature provides display offset for custom applications. Setpoints are permanently held in memory (no batteries used) and retained during power outages. Extended fan operation feature can be used to operate fan for 90 seconds after Y turns off. utput atings: Maximum current for each output is 1 Amp. iring: onnection to XM ontrol ATA22U01 Thermostat ompressor Heating Stage 2 eversing Valve Fan 24Vac Hot 24Vac ommon Fault LED Y / L Note 1 XM Y Note 1: ptional onnection for Heating Stage 2 operation, Thermostat "" option must be configured as " - ff".this configuration uses the compressor only for 1st stage heating and compressor plus auxilliary heat for 2nd stage operation. The thermostat is configured as a two stage heat / one stage cool thermostat for single speed units with PS fan and backup heat. For two-stage units with backup heat or units with EM fan and backup heat, a three stage heat / 2 stage cool thermostat is required. 4 limatemaster esidential Thermostats - ev.: 02/13/06

5 esidential Thermostats 6.25 in [158.8mm] ATA32U01 Three Heat / Two ool Auto / Manual hangeover Non-Programmable 4.25 in [108.0mm] 1.1 in Depth [27.9mm] Features (cont.): Menu-driven programming with fi ve navigation buttons (UP/ DN/LEFT/IHT/SELET) for ease of use Fault indication with red backlight display onfi gurable service interval messages and servicing contractor contact information Keypad lockout Back-plate wiring connections for easy installation Exclusive fault identifi cation (hen used with XM or DXM) displays fault from XM/DXM board (e.g. condensate overfl ow) and suggests possible causes ompatible with AST008 sensor for use as remote and/or outdoor sensor Dual fuel capable Mounting: UP 0.72" [18.3mm] Specifications: Electrical ating: Input Power: 18 to 30 VA, 50/60 Hz perating onditions: 32ºF to 104ºF [0º to 40º] 10% to 95% non-condensing 2.90" [73.7mm] 6.25" [158.8mm] Temperature Settings: Set point range: 40ºF to 90ºF [4º to 32º], +/- 2ºF [1º] utput atings: Maximum current for each output is 1.0 Amp (2.0 max. output total). 0.62" [15.7mm] iring: onnection to EM ontrol Application: The ATA32U01 Thermostat provides 3 stages heating, 2 stages of cooling, and non-programmable temperature control of 24V water-source heat pump equipment. Features: Heat-ff-ool-Em Heat-Auto System Selections ºF or º temperature display Individual heat and cool set points Zero temperature droop performance Automatic or manual changeover Set points are permanently held in memory (no batteries used) and retained during power outages oom temperature offset adjustment Large backlit dot matrix display is activated whenever a key is pressed and remains on for 25 seconds ATA32U01 Thermostat ompressor ompressor Stage 2 Auxiliary Heat eversing Valve Fan 24Vac Hot 24Vac ommon Fault LED L EM limatemaster esidential Thermostats - ev.: 02/13/06 5

6 limatemaster 6.25 in [158.8mm] ATP32U01 Three Heat / Two ool Auto / Manual hangeover Programmable (7 Day) Features (cont.): 4.25 in [108.0mm] 1.1 in Depth [27.9mm] Mounting: UP 0.72" [18.3mm] oom temperature offset adjustment Progressive ecovery anticipates the time required to bring the space temperature to the next programmed event, and brings on the heat pump accordingly Large backlit dot matrix display is activated whenever a key is pressed and remains on for 25 seconds Menu-driven programming with fi ve navigation buttons (UP/ DN/LEFT/IHT/SELET) for ease of use Fault indication with red backlight display onfi gurable service interval messages and servicing contractor contact information Keypad lockout Back-plate wiring connections for easy installation Exclusive fault identifi cation (hen used with XM or DXM) displays fault from XM/DXM board (e.g. condensate overfl ow) and suggests possible causes ompatible with AST008 sensor for use as remote and/or outdoor sensor Dual fuel capable Specifications: Electrical ating: Input Power: 18 to 30 VA, 50/60 Hz 2.90" [73.7mm] 6.25" [158.8mm] perating onditions: 32ºF to 104ºF [0º to 40º] 10% to 95% non-condensing Temperature Settings: Set point range: 40ºF to 90ºF [4º to 32º], +/- 2ºF [1º] 0.62" [15.7mm] utput atings: Maximum current for each output is 1.0 Amp (2.0 max. output total). Application: The ATP32U01 Thermostat provides 3 stages heating, 2 stages of cooling, and programmable temperature control of 24V water-source heat pump equipment. iring: onnection to EM ontrol ATP32U01 Thermostat EM Features: 7-day programming. Four periods per day. ºF or º temperature display 12 or 24 hour clock Individual heat and cool set points Zero temperature droop performance Automatic (program mode) or manual (HLD) operation onvenient overrides allow temporary set point changes Set points are permanently held in memory (no batteries used) and retained during power outages ompressor ompressor Stage 2 Auxiliary Heat eversing Valve Fan 24Vac Hot 24Vac ommon Fault LED L 6 limatemaster esidential Thermostats - ev.: 02/13/06

7 esidential Thermostats 6.25 in [158.8mm] ATP32U02 Three Heat / Two ool Auto / Manual hangeover Programmable (7 Day) ith Humidity ontrol 4.25 in [108.0mm] 1.1 in Depth [27.9mm] Mounting: UP 0.72" [18.3mm] 2.90" [73.7mm] 6.25" [158.8mm] Features (cont.): Four periods per day ºF or º temperature display 12 or 24 hour clock Individual heat and cool set points Zero temperature droop performance Automatic (program mode) or manual (HLD) operation onvenient overrides allow temporary set point changes Set points are permanently held in memory (no batteries used) and retained during power outages oom temperature offset adjustment Progressive ecovery anticipates the time required to bring the space temperature to the next programmed event, and brings on the heat pump accordingly Large backlit dot matrix display is activated whenever a key is pressed and remains on for 25 seconds Menu-driven programming with fi ve navigation buttons (UP/ DN/LEFT/IHT/SELET) for ease of use Fault indication with red backlight display onfi gurable service interval messages and servicing contractor contact information Keypad lockout Back-plate wiring connections for easy installation Exclusive fault identifi cation (hen used with XM or DXM) displays fault from XM/DXM board (e.g. condensate overfl ow) and suggests possible causes ompatible with AST008 sensor for use as remote and/or outdoor sensor Dual fuel capable 0.62" [15.7mm] Specifications: Electrical ating: Input Power: 18 to 30 VA, 50/60 Hz Application: The ATP32U02 Thermostat provides 3 stages heating, 2 stages of cooling, and programmable temperature/humidity control of 24V water-source heat pump equipment. Features: 7-day programming. Programmable or non-programmable operation Dehumidifi cation output is designed to work with limadry Modulating eheat option or with EM fan motor dehumidifi cation mode Integrated control of both temperature and relative humidity Integrated control eliminates separate thermostat and dehumidistat/humidistat Thermostat can be programmed to use humidifi cation output to control a humidifi er perating onditions: 32ºF to 104ºF [0º to 40º] 10% to 95% non-condensing Temperature Settings: Set point range: 40ºF to 90ºF [4º to 32º], +/- 2ºF [1º] Dehumidifi cation set point range: 15% to 95% H Humidifi cation set point range: 10% to 45% H utput atings: Maximum current for each output is 1.0 Amp (2.0 max. output total). limatemaster esidential Thermostats - ev.: 02/13/06 7

8 limatemaster iring: Units with EM Fan onnection to EM ontrol ATP32U02 Thermostat EM ATP32U02 Three Heat / Two ool Auto / Manual hangeover Programmable (7 Day) ith Humidity ontrol ompressor ompressor Stage 2 Auxiliary Heat Units with limadry Dehumidification eversing Valve DH DH onnection to DXM ontrol Fan 24Vac Hot 24Vac ommon Fault LED L ATP32U02 Thermostat ompressor ompressor Stage 2 DXM Units with XM or DXM board and EM fan motor, utilizing EM dehumidification mode (w/o limadry option) Notes: 1) EM dehumidification mode slows down fan speed in the cooling mode when dehumidification output from thermostat is active. Normal heating and cooling fan speeds are not affected. 2) EM board DIP switch S9 must be in dehumid. mode. Auxiliary Heat Dehumidification eversing Valve Fan 24Vac Hot 24Vac ommon Fault LED DH L 1 H /2 Units with EM Fan and limadry hole House Dehumidification ption Unit with limadry ption and DXM board (PS fan motor) onnection to EM & DXM ontrol ATP32U02 Thermostat EM DXM ompressor ompressor Stage 2 Auxiliary Heat 1 Dehumidification DH H eversing Valve /2 Fan 24Vac Hot 24Vac ommon Fault LED L Single or two-stage unit with limadry ption and DXM board (EM fan motor) 8 limatemaster esidential Thermostats - ev.: 02/13/06

9 esidential Thermostats limatemaster esidential Thermostats - ev.: 02/13/06 9

10 limatemaster 10 limatemaster esidential Thermostats - ev.: 02/13/06

11

12 evision Log Date Page Description 02/13/06 All First Published IS 9001:2000 ertified Quality: First & Always 7300 S.. 44th Street klahoma ity, K Phone: Fax: limatemaster works continually to improve its products. As a result, the design and specifi cations of each product at the time for order may be changed without notice and may not be as described herein. Please contact limatemaster s ustomer Service Department at for specifi c information on the current design and spec i fi ca tions. Statements and other in for ma tion contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely limatemaster s opinion or com men da tion of its products. The management system governing the manufacture of limatemaster s products is IS 9001:2000 certifi ed. P806 limatemaster, Inc ev.: 02/13/06D

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types Installation Guide VisionPRO TH8000 Series Touch-screen Programmable Thermostat This manual covers the following models TH8110U: For 1 Heat/1 Cool systems TH8320U: For up to 3 Heat/2 Cool systems TH8321U:

More information

HEAT HEAT COOL HEAT PUMP COOL

HEAT HEAT COOL HEAT PUMP COOL OWNER S MANUAL RESIDENTIAL THERMOSTAT P/N P374-1800 HEAT COOL HEAT PUMP Su AUTO 0I20: Pm 74 COOL HEAT 27 7-DAY MABLE DIGITAL THERMOSTAT 3 Configurable Outputs Accepts Optional Humidity Module: Control

More information

Installation Instructions

Installation Instructions Installation Instructions Model TSTATG2111 Use with most systems: 2-Heat, 1-ool 1- Day Prog ram m ab l e Digital Thermostat u p t o 2 - H e a t & 1 - o o l ontrol up to 2 Heat & 1 ool Stages Backlit Display

More information

Install Guide 3M-50. Caution. Caution

Install Guide 3M-50. Caution. Caution PG 1 Install Guide 3M-50 aution Your thermostat is a precise instrument, handle it with care. Turn off electricity to the HVA system before installing or servicing thermostat or any part of the system.

More information

Safety & Installation Instructions

Safety & Installation Instructions Home omfort ontrol Model 8910 READ AND SAVE THESE INSTRUTIS Safety & Installation Instructions Table of contents Installation Thermostat installation location recommendations.. 2 Thermostat mounting...

More information

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved.

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved. Sensi TM Wi-Fi Programmable Thermostat MANUAL OPERATION Version: March 2016 2016 Emerson Electric Co. All rights reserved. Contents MANUAL OPERATION GUIDE Buttons and Icons 3 Basic Functionality 4 Manual

More information

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps Operation and Maintenance Manual Model: 71028004 Applies to: Single Circuit Water-to-Water Twin Circuit Units Without DDC Controls MAMM WHSP

More information

Heating and Cooling Basics Thermostat Control

Heating and Cooling Basics Thermostat Control Heating and Cooling Basics Thermostat Control UNI-LINE PRODUCT KNOWLEDGE 2012 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys are proprietary

More information

1 For All Non-Programmable Digital Thermostat

1 For All Non-Programmable Digital Thermostat OWNER'S MANUAL P/N P474-0100 1 For All Non-Programmable Digital Thermostat TOTALINE 68 Dual Setpoint Very easy to program Thermoglow Backlight No batteries required Auto-Changeover Locking Keypad Meets

More information

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types Installation Guide LR-HWLV-HVAC TouchPRO Wireless Touchscreen Thermostat System Types Gas, oil, or electric heat with air conditioning Warm air, hot water, high efficiency furnaces, heat pumps, steam,

More information

T-100-R Installation Guide

T-100-R Installation Guide T-100-R Installation Guide Table of Contents Page 2 Overview T-100-R Z-Wave Thermostat 3-4 Installation HVAC System Setup 6 Installer Settings Menu Items 7-9 Installer Settings Summary 10-11 Wiring Standard

More information

The Totaline Premier Series of thermostats consists of programmable and non programmable air conditioner, heat pump and thermidistat control.

The Totaline Premier Series of thermostats consists of programmable and non programmable air conditioner, heat pump and thermidistat control. The Totaline Premier Series of thermostats consists of programmable and non programmable air conditioner, heat pump and thermidistat control. These units feature mercury free non lead based electronic

More information

Communicating Wall Control Installation Manual TSTAT0101SC

Communicating Wall Control Installation Manual TSTAT0101SC Communicating Wall Control Installation Manual TSTAT0101SC U.S. Patent No. 7,243,004 U.S. Patent No. 7,775,452 616 01 1017 02 08/07/12 Safety Considerations... 7 Introduction... 8 Quick Start... 9 Set

More information

INSTALLATION MANUAL RS4220 RS5220 RS6220 RS4110 RS5110 RS6110

INSTALLATION MANUAL RS4220 RS5220 RS6220 RS4110 RS5110 RS6110 RS4110 RS5110 RS4220 RS5220 RS6220 INSTAATIN MANUA 352-00060-001 Rev. A RS4000 Series RS5000 Series RS6000 Series Thank you for purchasing a Robertshaw thermostat. This manual will describe how to install

More information

Installation Instructions

Installation Instructions TP-PRH-A, TP-NRH-A Performance Series Edge Thermidistat Control Installation Instructions Programmable Control A07049 A07048 Non Programmable Control Designed and Assembled in the USA. NOTE: Read the entire

More information

Nest Learning Thermostat Pro installation & configuration guide

Nest Learning Thermostat Pro installation & configuration guide Nest Learning Thermostat Pro installation & configuration guide Need help? Help online: http://support.nest.com/certified Nest Certified Professional support: 1-855-VIP-NEST (1-855-847-6378) Hours: 5am-9pm

More information

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface

More information

Owner s Manual. Model 8476 Thermostat with Event-Based Air Cleaning. Includes Operating Instructions and Warranty Information

Owner s Manual. Model 8476 Thermostat with Event-Based Air Cleaning. Includes Operating Instructions and Warranty Information Model 8476 Thermostat with Event-Based Air Cleaning Owner s Manual Includes Operating Instructions and Warranty Infmation READ AND SAVE THESE INSTRUCTIONS Table of contents About your new thermostat Thermostat

More information

ACONT900AC43UA Communicating, Programmable Comfort Control

ACONT900AC43UA Communicating, Programmable Comfort Control ACONT900AC43UA Communicating, Programmable Comfort Control OWNER S GUIDE Pub No. 69-1820-04 TABLE OF CONTENTS Page Contents 3 Features 4 Home Screen 6 Programming Your Heating and Cooling Schedule 14 Operating

More information

Installation Guide. Prestige IAQ with Equipment Interface Module. RedLINK to Equipment Interface Module. RedLINK to TrueZONE Wireless Adapter

Installation Guide. Prestige IAQ with Equipment Interface Module. RedLINK to Equipment Interface Module. RedLINK to TrueZONE Wireless Adapter TM TM TM Prestige IAQ with Equipment Interface Module Installation Guide edlink to Equipment Interface Module 2 Wires for Power O edlink to TrueZONE Wireless Adapter 2 Wires for Power eference to key features

More information

QUICK INSTALLATION GUIDE

QUICK INSTALLATION GUIDE QUICK INSTALLATION GUIDE Read Installer Notes before removing cover from Thermostat. 1F85RF-275 Wireless Remote Kit INSTALLER NOTES IMPORTANT Do not apply power to the thermostat or wireless sensor until

More information

SC 2201. Installation, Operation & Application Guide

SC 2201. Installation, Operation & Application Guide SC 2201 Manual Changeover Non-Programmable Hardwired Non-Programmable Electronic Thermostat For use with Heat Pumps Up to 2-Stage Heat, 2-Stage Cool 30-Minute Power Loss Memory etention For use with 24

More information

Thermostats. comfort at your command

Thermostats. comfort at your command comfort at your command Carrier has met temperature control needs worldwide with its thermostats. Carrier thermostats provide computer-like intelligence with extremely simple operation in an elegant package.

More information

Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify

Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify TABLE OF CONTENTS About your new thermostat Features...2

More information

Install Guide CT101. Caution. Caution

Install Guide CT101. Caution. Caution Install Guide CT101 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the

More information

COMFORT CONTROL - 4 HEAT (GAS, OIL*, OR ELECTRIC)/3 COOL/HEAT PUMP COMMUNICATING PROGRAMMABLE 3 WIRE HOOKUP

COMFORT CONTROL - 4 HEAT (GAS, OIL*, OR ELECTRIC)/3 COOL/HEAT PUMP COMMUNICATING PROGRAMMABLE 3 WIRE HOOKUP COMFORT CONTROL - 4 HEAT (GAS, OIL*, OR ELECTRIC)/3 COOL/HEAT PUMP COMMUNICATING PROGRAMMABLE 3 WIRE HOOKUP ALL phases of this installation must comply with NATIONAL, STATE, AND LOCAL CODES INSTALLER S

More information

Variable Air Volume - VAV

Variable Air Volume - VAV Mode Enable Sensor Options Variable Air Volume - VAV The temperature of this sensor will determine if the unit is in heating, cooling or vent mode during occupied operation. The following options are available:

More information

Blue Easy Reader Thermostat 1F95EZ-0671. Homeowner s Guide

Blue Easy Reader Thermostat 1F95EZ-0671. Homeowner s Guide Blue Easy Reader Thermostat 1F95EZ-0671 Homeowner s Guide Message to Homeowners Congratulations on choosing the Emerson Blue Easy Reader Thermostat. Blue Easy Reader is designed to be the easiest thermostat

More information

Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats

Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats Communicating Thermostats Add More Flexibility to Building Automation with New Communicating Thermostats More Choices. More Possibilities. From zone control to rooftop units and nearly everything in between,

More information

HEAT PUMP PROGRAMMABLE THERMOSTAT

HEAT PUMP PROGRAMMABLE THERMOSTAT HEAT PUMP PROGRAMMABLE THERMOSTAT SA PM 3 COOL TEMP Form 44014-01 r010408 Model 43168 Owners Manual 1 Congratulations! Heat Pump Programmable Thermostat Model 43168 THERMOSTAT CONTROLS Switches & Buttons...15

More information

Features and Benefits

Features and Benefits Refrigeration 2 eatures and Benefits Based on IR32 Parameters Real Time lock ( RT ) Model Specific (defrost based on real time 7 day 24 hour) HAP (Hazard Analysis and ritical ontrol Point) Alarm Available

More information

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the

More information

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work. Install Guide CT100 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the

More information

How To Set Up A Furnace Pump

How To Set Up A Furnace Pump ork etail System Specific iring Diagrams January 2012 Using Honeywell hermostats Index for Low Voltage iring Affinity Units utdoor Indoor System Description Page ZH 2 Stage HP AV or MV Variable Speed Air

More information

Emergency Heat slide switch on the panel or an external switch. Do not use the panel switch or the external switch if Dip switch #4 is set to HP.

Emergency Heat slide switch on the panel or an external switch. Do not use the panel switch or the external switch if Dip switch #4 is set to HP. Installation Instructions The ED4 is a 4-zone panel that can control gas/ electric, hydronic, electric and both conventional and dual fuel heat pumps with multi-stage heating and cooling. Low cost heat-cool

More information

Workshop 7 PC Software - Tracker

Workshop 7 PC Software - Tracker Workshop 7 PC Software - Tracker Goal: You will startup and perform advanced setup functions using Tracker PC software. You will also setup equations to control MP503 binary outputs. The Binary Output

More information

T8000, T8001 Programmable Thermostat

T8000, T8001 Programmable Thermostat T8000, T800 Programmable Thermostat INSTALLATIN INSTUTINS APPLIATIN The T8000, T800 Thermostats provide single-stage, programmable temperature control for 4 Vac heatingcooling systems with manual changeover

More information

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES

More information

WHITE-RODGERS COMFORT-SET 90 SERIES

WHITE-RODGERS COMFORT-SET 90 SERIES INSTALLATI DESCRIPTI WHITE-RODGERS COMFORT-SET 90 SERIES MULTI-STAGE INSTALLATI/CFIGURATI This White-Rodgers Automatic Setback Digital Thermostat uses microcomputer technology to provide precise time and

More information

NOTE: Append this Operation IB to the Install IB to make one IB-booklet. Need a divider tab between the 2 sections. Blank page remove.

NOTE: Append this Operation IB to the Install IB to make one IB-booklet. Need a divider tab between the 2 sections. Blank page remove. Product Name: CT101 Document Title: CT101 Operation Guide Document Type Code: IBOE Part Number: 1202-004-002 20apr12 Iris inclusion text added mtf 9apr12 bs edits mtf 14mar12 ch edits mtf 13mar12 initial

More information

TC-9102 Series Surface Mount Temperature Controllers

TC-9102 Series Surface Mount Temperature Controllers TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

RedLINK Wireless Comfort Systems. RedLINK Connects.

RedLINK Wireless Comfort Systems. RedLINK Connects. RedLINK Wireless Comfort Systems RedLINK Connects. TM THERMOSTATS ZONING AIR CLEANERS HUMIDIFIERS DEHUMIDIFIERS UV SYSTEMS VENTILATION WATER SOLUTIONS wireless TM Your Customers Are Connected. Wireless.

More information

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings. 1100 & 1400 Energy Controllers Satchwell 1100 & 1400 for energy-efficient temperature control in smaller buildings. 02 1100 & 1400 Energy Controllers Features he 1100 and 1400 Energy Controllers are self-configuring

More information

Thermostat with display

Thermostat with display H/LN4691-0 674 59-64170 Thermostat with display RA00118AA_I-01PC-13W39 www.homesystems-legrandgroup.com Thermostat with display Contents Thermostat with display 1 Introduction 4 1.1 Warnings and recommendations

More information

Wireless Solutions. Application Selection Guide

Wireless Solutions. Application Selection Guide Wireless Solutions Application Selection Guide THERMOSTATS ZONING AIR CLEANERS HUMIDIFIERS DEHUMIDIFIERS UV SYSTEMS VENTILATION WATER SOLUTIONS COMBUSTION RedLINK Wireless Systems TrueZONE Panel Return

More information

WHITE PAPER #: CLIMATEMASTER KNOWLEDGE SERIES: HEAT PUMP DESIGN FOR 100% OUTSIDE AIR SYSTEMS THE SMART SOLUTION FOR ENERGY EFFICIENCY

WHITE PAPER #: CLIMATEMASTER KNOWLEDGE SERIES: HEAT PUMP DESIGN FOR 100% OUTSIDE AIR SYSTEMS THE SMART SOLUTION FOR ENERGY EFFICIENCY WHTE PPE #: 5 THE SMT SUTN F ENEGY EFFENY MTEMSTE KNWEDGE SEES: HET PUMP DESGN F 100% UTSDE SYSTEMS WTE-SUE HET PUMP SYSTEMS Table of ontents: ntroduction... 2 Background on oops... 2 Heat Pump Principles...

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage

More information

Commercial Refrigeration Temperature and Defrost Controls

Commercial Refrigeration Temperature and Defrost Controls Commercial Refrigeration Temperature and Defrost Controls UNI-LINE PRODUCT KNOWLEDGE 2010 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys

More information

TABLE OF CONTENTS. 1.1 Features... 1. 2.1 System Screen... 4 2.2 Main Unit Screen... 6 2.3 Navigating Through the Liebert icom Menus...

TABLE OF CONTENTS. 1.1 Features... 1. 2.1 System Screen... 4 2.2 Main Unit Screen... 6 2.3 Navigating Through the Liebert icom Menus... Liebert icom User Manual -Intelligent Communications & Monitoring for Liebert Challenger 3000, Liebert Challenger ITR, Liebert CW, Liebert DS Liebert PeX with Software Version PA2.01.029.03R TABLE OF

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Document updates: Version Data Description V1.0 2015.05.25 Finish new document HVAC Controller User Manual INDEX 1. Overview...1

More information

APPLICATIONS SPECIFICATIONS CAUTION. Blue Universal Thermostat with Automatic Heat/Cool Changeover Option. Save these instructions for future use!

APPLICATIONS SPECIFICATIONS CAUTION. Blue Universal Thermostat with Automatic Heat/Cool Changeover Option. Save these instructions for future use! Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. APPLICATIONS

More information

Wireless and Prestige Comfort Systems. Frequently Asked Questions Guide

Wireless and Prestige Comfort Systems. Frequently Asked Questions Guide Wireless and Prestige Comfort Systems Frequently sked uestions Guide TM RedLINK Wireless Technology TM The Description What is RedLINK? RedLINK is the first wireless protocol developed specifically for

More information

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE

More information

COMPTROL 5000 INDEX 52. Issue 5.99 AIR CONDITIONING MICROPROCESSOR OPERATING INSTRUCTIONS. STULZ GmbH, Hamburg

COMPTROL 5000 INDEX 52. Issue 5.99 AIR CONDITIONING MICROPROCESSOR OPERATING INSTRUCTIONS. STULZ GmbH, Hamburg COMPTROL 5000 INDEX 52 Issue 5.99 AIR CONDITIONING MICROPROCESSOR STULZ GmbH, Hamburg OPERATING INSTRUCTIONS Contents Page INTRODUCTION... 4 NOTES ON SAFETY... 4 PAGE CODE... 4 DESCRIPTION OF THE CONTROLLER...

More information

INSTALLER S SYSTEM SETUP GUIDE

INSTALLER S SYSTEM SETUP GUIDE 2009 Lennox Industries Inc. Dallas, Texas, USA INSTALLER S SYSTEM SETUP GUIDE icomfort Thermostat Touch Screen Programmable Communicating Thermostat CONTROLS 506052 01 11/09 Litho U.S.A. Shipping and Packing

More information

TEDDINGTON. Intuitive control. TLC 700 The multifunctional controller

TEDDINGTON. Intuitive control. TLC 700 The multifunctional controller Intuitive control TLC 700 The multifunctional controller TLC 700 The intelligent controller for complex systems TEDDINGTON As easy as Teddington air curtain systems are the ultimate when it comes to the

More information

Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat

Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat MOUNTING LOCATIONS Refer to the guidelines below and Fig. 1 5 for mounting locations of the Discharge and Return Air Temperature Sensors.

More information

TB7600 Series Communicating RTU Thermostats with Humidity Control

TB7600 Series Communicating RTU Thermostats with Humidity Control TB7600 Series Communicating RTU Thermostats with Humidity Control TB7600 Series Thermostat INSTALLATION INSTRUCTIONS APPLICATION The TB7600 Series PI thermostat family is specifically designed for single

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

Installation Instructions

Installation Instructions TP --- PAC, TP --- PHP TP --- NAC, TP --- NHP Performance Series AC / HP Thermostat Installation Instructions A07049 Programmable Control A07048 Non-Programmable Control Designed and Assembled in the U.S.A.

More information

1F82-0261 5/1/1 Day Programmable. 1F82-0261 Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1

1F82-0261 5/1/1 Day Programmable. 1F82-0261 Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1 Blue 2 Heat Pump Thermostat Heat Pump Installation and Operating Instructions Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING

More information

TABLE OF CONTENTS. 1.1 Features... 1. 2.1 Control Interface Large Display... 4. 2.1.1 Navigating to Various Views in the Liebert icom...

TABLE OF CONTENTS. 1.1 Features... 1. 2.1 Control Interface Large Display... 4. 2.1.1 Navigating to Various Views in the Liebert icom... Liebert icom User Manual -Intelligent Communications & Monitoring for Liebert Challenger 3000, Liebert CW and Liebert DS with Software Version PA2.01.48R TABLE OF CONTENTS 1.0 INTRODUCTION..........................................................1

More information

ENERGY STAR Programmable Thermostats

ENERGY STAR Programmable Thermostats ENERGY STAR Programmable Thermostats Draft 1 Version 2.0 Stakeholder Meeting November 18, 2009 Katharine Kaplan, U.S. EPA Doug Frazee, ICF International Agenda Welcome & Introductions Drivers and Context

More information

FX07 Field Controller

FX07 Field Controller Product Bulletin FX07 Field Controller Issue Date March 25, 2008 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,

More information

Mode Switch. Fan Switch Menu button Program button

Mode Switch. Fan Switch Menu button Program button Operation 3M-30 Day Time of day Target Temperature Time Slot Touch Screen Current Room Temperature Thermostat Mode Statement of use: The 3M-30 can be used with millivolt, 24VAC, single and 2 stage conventional

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! HITE-RDERS 1F80-51 Programmable Electronic Digital Thermostat INSTALLATIN AND PERATIN INSTRUCTINS perator: Save these instructions for future use! FAILURE T READ AND FLL ALL INSTRUCTINS CAREFULL EFRE INSTALLIN

More information

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module 1. General Description 1 2. General Warnings 1 3. Interface 2 4. Temp Alarms Setting 3 5. Programming 3 6. Light Management 4 7. Installation and

More information

June 27, 2009. Dear Customer,

June 27, 2009. Dear Customer, June 27, 2009 Dear Customer, We are pleased to announce new products and sales tools to help you have even more success with the Pro1 line of professional heating and cooling products. Please review the

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

1-877-654-9394. UP400 Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com

1-877-654-9394. UP400 Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com UP400 Programmable Thermostat Installation Instructions & User Guide For Installation Help 1-877-654-9394 White-Rodgers.com 2011 Printed in China White-Rodgers 8100 West Florissant Avenue St. Louis, MO

More information

Y-200 Multi-Stage Sequencer

Y-200 Multi-Stage Sequencer Y-200 Multi-Stage Sequencer Designed for use with single or multiple space heating or hot water supply systems, the Y-200 is offered in 4- and 8-stage configurations and is available loose or factory-mounted

More information

WARNING. Damper Control Module for. Comfort Sync Zoning System CONTROLS KITS AND ACCESSORIES

WARNING. Damper Control Module for. Comfort Sync Zoning System CONTROLS KITS AND ACCESSORIES 2014 ALLIED AIR ENTERPRISES 215 METROPOLITAN DR. WEST COLUMBIA, SC 29170 CONTROLS KITS AND ACCESSORIES 507376-01 5/2014 Damper Control Module for Comfort Sync Zoning System Installation Instructions for

More information

T600xxx-4 and T600xxx-4+PIR Series Thermostat Controllers

T600xxx-4 and T600xxx-4+PIR Series Thermostat Controllers T600xxx-4 and T600xxx-4+PIR Series Thermostat Controllers Product Bulletin T600HCx-4, T600HPx-4, T600MSx-4, T600MEP-4, T600HCx-4+PIR, T600HPx-4+PIR, T600MSx-4+PIR, T600MEP-4+PIR The T600xxN-4 and T600xxN-4+PIR

More information

1F82-261 Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

1F82-261 Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION ELECTRICAL DATA Electrical Rating: 20 to

More information

Water-Source Heat Pump

Water-Source Heat Pump Application Jauary 1999 Water-Source Heat Pump Application Economizer (Optional) BO-6,7 Discharge Air Temperature (Optional) Heating/Cooling Coil AI-6 Outdoor Air Temperature (Optional) Aux Input AI-5

More information

Installer Guide smart connect

Installer Guide smart connect Installer Guide smart connect TM 7330 Wireless Remote Humidity Sensor Please read all instructions before proceeding. The wireless remote humidity sensor monitors the humidity passing through the return

More information

Application Engineering

Application Engineering Application Engineering February 2011 Electronic Unit Controller Table of Contents 1. Introduction and Features... 2 1.1 Technical Specifi cations... 3 1.2 Pressure Probe Error Bypass... 3 1.3 Bump Start...

More information

Installation and Setup Guide

Installation and Setup Guide Installation and Setup Guide Color Touchscreen Programmable Thermostat ComfortSense 7500 (13H14) Table of Contents Shipping and Packing List... 2 ComfortSense 7500 Thermostat... 3 Features... 3 Thermostat

More information

1F95-1291 7 Day 5/1/1 Day Non-Programmable. Maximum Stages Heat/Cool 1/1 2/2 3/1 4/2

1F95-1291 7 Day 5/1/1 Day Non-Programmable. Maximum Stages Heat/Cool 1/1 2/2 3/1 4/2 Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. Big Blue Humidity

More information

General Information. Do programmable thermostats really save energy?

General Information. Do programmable thermostats really save energy? General Information Do programmable thermostats really save energy? Yes, programmable thermostats can save energy which in turn saves you money on your utility bill. The US Department of Energy states

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark SET1E Electronic timeswitch for heating & hot water Installation & User Instructions Certification Mark Index INDEX Installation Product specification 3 Installation 4-5 Wiring 5-10 Replacement 11-13 User

More information

1F87-361 Programmable Electronic Digital Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

1F87-361 Programmable Electronic Digital Thermostat INSTALLATION AND OPERATION INSTRUCTIONS 1F87-361 Programmable Electronic Digital Thermostat INSTALLATIN AND PERATIN INSTRUCTINS perator: Save these instructions for future use! FAILURE T READ AND FLL ALL INSTRUCTINS CAREFULL EFRE INSTALLIN R

More information

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP

More information

English plain text messages with constant backlight that brightens during user interaction. On/Off, Floating, or Proportional 0 to 10 VDC Control

English plain text messages with constant backlight that brightens during user interaction. On/Off, Floating, or Proportional 0 to 10 VDC Control TEC26x6(H)-4 and TEC26x6H-4+PIR Series BACnet MS/TP Networked Thermostat Controllers with Dehumidification Capability, Fan Control, and Occupancy Sensing Capability Product Bulletin Code No. LIT-12011587

More information

Programmable Thermostats Installation, Start-Up, and Operating Instructions

Programmable Thermostats Installation, Start-Up, and Operating Instructions Visit www.carrier.com Programmable Thermostats Installation, Start-Up, and perating Instructions NTE: ead the entire instruction manual before starting the installation. This symbol indicates a change

More information

Wireless Thermostats 230v and Battery Operated Instruction Manual

Wireless Thermostats 230v and Battery Operated Instruction Manual Wireless Thermostats 230v and Battery Operated Instruction Manual For models: JGSTATW2W JGSTATW2B JGSTATW1W JGSTATW1B Contents Box contents: Wireless Thermostats 230v and Battery Operated Instruction Manual

More information

T5000 T000 LCD Digital Fan Coil Thermostat

T5000 T000 LCD Digital Fan Coil Thermostat T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL RCS MODEL ZC4 4 ZONE HVAC INSTALLATION AND OPERATION MANUAL DCN: 141-0020-02 /0/03 INTRODUCTION The 4 Zone HVAC Controller series allows up to 4 standard electronic thermostats to independently control

More information

GETTING STARTED WITH THE MIPOWER MANAGEMENT SYSTEM

GETTING STARTED WITH THE MIPOWER MANAGEMENT SYSTEM GETTING STARTED WITH THE MIPOWER MANAGEMENT SYSTEM This Quick Start guide will help you start using the MiPower Management System provided by Grayson Collin Electric Cooperative. You should create your

More information

1F95-0671 7 Day 5/1/1 Day Non-Programmable. Yes

1F95-0671 7 Day 5/1/1 Day Non-Programmable. Yes Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. Blue Universal

More information

1F95-1280 7 Day 5/1/1 Day Non-Programmable. W/ Economizer Max. Stage Heat/Cool 1/1 1/2 2/2 2/3 3/1 3/2 4/2 4/3

1F95-1280 7 Day 5/1/1 Day Non-Programmable. W/ Economizer Max. Stage Heat/Cool 1/1 1/2 2/2 2/3 3/1 3/2 4/2 4/3 Blue Commercial Touchscreen Universal Thermostat with Damper or Economizer Control and Automatic Heat/Cool Changeover Option Single Stage, Multi-Stage, Heat Pump Save these instructions for future use!

More information

Protects against unwanted thermostat controller tampering. Increases occupancy comfort by providing dehumidification.

Protects against unwanted thermostat controller tampering. Increases occupancy comfort by providing dehumidification. TEC22x6(H)-4 and TEC22x6H-4+PIR Series LONWORKS Network Thermostat Controllers with Dehumidification Capability, Fan Control, and Occupancy Sensing Capability Product Bulletin Code No. LIT-12011607 Issued

More information

Contents. Introduction

Contents. Introduction TION Contents Introduction...1 Basics...2 Main Menu Structure...3 Time Schedule Menu...4 Settings Menu...5 Reports Menu...6 Date / Time Adjustment Menu...7 Introduction TION is an advanced control device

More information

T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control

T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control T Series arge CD Digital Thermostat 0/0 VAC -pipe/-pipe fan coil control Data sheet Application T digital thermostats are designed for application of -speed fan and s in fan coil system. Including: -pipe

More information

$SSOLFDWLRQ1RWH*; ³6LQJOHORRSRXWSXWV 6HULHV6&*(1 ', $2 3, $2

$SSOLFDWLRQ1RWH*; ³6LQJOHORRSRXWSXWV 6HULHV6&*(1 ', $2 3, $2 $SSOLFDWLRQ1RWH; ³6LQJOHORRSRXWSXWV 6HULHV6&(1 uropean lectronic ontrols atalog atalog section B Application Note G12 Issue Date 05.96 2 YHUYLHZ $+8ZLWK FRLOV 3DVVLYH,QSXW 17&.ƒ&RXWSXWV9 analog input 0/10

More information

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac II air conditioner is a vertical, wall mounted, cost effective air conditioner

More information