IFORMATION SHEET FOR INTERLABORATORY TEST PARTICIPANTS
|
|
- Derick Booth
- 7 years ago
- Views:
Transcription
1 IFORMATION SHEET FOR INTERLABORATORY TEST PARTICIPANTS Procedure for the interlaboratory test on the sampling and determination of particulate matter (dust) containing heavy metals at the Emission Simulation Facility (ESA) 1. Director: 2. Location: Edgar Vogel HESSISCHES LANDESAMT FÜR UMWELT UND GEOLOGIE Dezernat Luftreinhaltung / Emissionen Ludwig-Mond-Str Kassel Tel. 0561/ FAX 0561/ HESSISCHES LANDESAMT FÜR UMWELT UND GEOLOGIE AUSSENSTELLE KASSEL Ludwig-Mond-Str Kassel Tel. 0561/ FAX 0561/ THE INTER-LABORATORY TEST TAKES PLACE ON THE 3RD FLOOR OF THE OFFICE BUILDING (ESA OPERATIONS ROOM, ROOM 373 / ESA-BETRIEBSRAUM, RAUM 3739 UNFORTUNATELY THERE IS NO LIFT AVAILABLE FOR THE TRANSPORT OF EQUIPMENT. Contact: 3. Participants: -Adress: emission@hlug.hessen.de Authorities in accordance with 26 of the Federal Immission Control Act (BImSchG), manufacturers of equipment, industrial departments engaged in emission monitoring, applicants for official monitoring tasks in accordance with 26 BImSchG. As much as four participants may participate in one interlaboratory Without prior affirmation by the organizer, for each institution no more than two persons should participate in one interlaboratory
2 Page 2 of 5 4. Task: Investigation of different mass concentrations of particulate exhaust components on the ESA and determination of their contents (heavy metals). 4.1 Preliminary remarks: The interlaboratory test is intended to quantify the concentrations of particulate matter and of some heavy metals (Cd, Co, Cu, Ni, Pb and Cr) being components of such dust. The Guidelines VDI 2066, Sheet 1, November 2006, and/or DIN EN of April 2002 are to be observed. A complete, appropriate set of equipment for recording and determining small amounts of particulate matter content using plane filter head equipment is necessary, incl. the equipment for investigate the standard emission conditions. This equipment has to be property of the institution which takes place in this interlaboratory 4.2 Operational state of the ESA during the interlaboratory test The facility is operated using ambient air mode which is cleaned by a particle filter EU 7 before use; this gas won t be warmed up. The ESA will operate in the medium performance range (between 3000 and 6500 m 3 /h). 4.3 Measuring level of the ESA and position of the measuring site The measuring levels are on the 3rd floor of the office building of the HLUG (room 371), approx m above ground level and at the end of a 14 m long vertical upstream flow track. To carry out the interlaboratory test 4 sampling openings (M2, M3, M9, M10) with an internal thread G3 (R3 ) will be used. 5. Measuring 5.1 Determination of the general conditions Before starting the interlaboratory test the following general conditions should be determined: choice of measurement points (are prescribed) investigation of the velocity profile in the cross section using two measuring axes; number of measurement points (two points per axis) air pressure at the height of the measurement level temperature in the measurement channel water vapour concentration (moisture in the measuring channel)
3 Page 3 of 5 calculation of the volume flow The measurement results for the general gas conditions are to be handed in by the participants of the interlaboratory test as part of the total information to be reported. 5.2 Sampling: Every participant must carry out the investigation of the particulate matter concentrations by isokinetic extraction of a dust-containing sampling volume in accordance with Guideline VDI 2066, Sheet 1 November 2006 "Particulate matter measurement. Dust measurement in flowing gases. Gravimetric determination of dust" and/or DIN EN April 2002 "Stationary source emissions - Determination of low range mass concentration of dust Part 1". All components of the testing equipment have to conform to the specifications of the VDI Guideline 2066 Sheet 1 November 2006 and/or DIN EN April Every individual measurement (sampling) takes exact half an hour. 10 individual measurements (including an introductory measurement) are to be carried out. The sampling is done simultaneously by all participants. Concentrations within the following specified areas are being offered: Phase 1 1 to 4 mg/m 3 Phase 2 4 to 7 mg/m 3 Phase 3 7 to 12 mg/m 3 (The specifications are to be understood only as indications) 5.3 Allocation of measurement openings The allocation of the measurement openings is set by the staff of the HLUG on site. 6. Treatment of the filters allocated 6.1 Gravimetric determination The gravimetric determination of the dust having been sampled is done according to standards in the laboratory of the measuring sites involved. 6.2 Fine particles contents The analytical investigation of the heavy metals content within the dust is done in the laboratory of the measuring sites involved with the relevant equipment (AAS, ICP etc.) in accordance with DIN EN May 2004 and VDI 2268 Sheets 1-4. Concentrations of the following elements (per sample) are to be determined: Cadmium Cobalt Copper
4 Page 4 of 5 Nickel Lead Chromium 7. Publication of results During the final interlaboratory test day every participant receives a specific participant number (PIN-Code). Using this ID code and going via the following Website results are to be electronically transferred to the HLUG. Also, the results shall be sent to the HLUG as a paper (e.g. printout of the filled input mask on the computer of the participant). The handover has to be done not later than 6 weeks after the final day of the interlaboratory At the latest, six weeks after the transfer of the results by the participant, he/she will receive the participation results from the HLUG, together with an invoice for the interlaboratory testing. Timeline of the interlaboratory test 1st interlaboratory test day (Tuesday) It is recommended to arrive on the day before (monday) 09:30 o clock 1 Welcome and introduction to interlaboratory testing. 10:00 till 12:00 o clock Assembly and testing of the measuring equipment. Determination of the general conditions of the gas flow. 12:00 till 12:45 o clock Lunch break 12:45 till 16:30 o clock Determination of the fine particles content by isokinetic extraction of sample volumes containing the dust to be determined, done according to Guideline VDI 2066, Sheet 1 November 2006, "Measuring of particles. Fine particles 1 To keep to the schedule it is essential to be punctual
5 Page 5 of 5 One introductory measurement, Three samples in accordance with the abovementioned Guideline. 2nd interlaboratory test day (Wednesday) 08:00 till 09:00 o clock Preparation Checking of general conditions. 09:00 till 12:00 o clock Investigation of the fine particles content by isokinetic extraction of sample volumes containing the dust to be determined, done according to Guideline VDI 2066, Sheet 1 November 2006, "Measuring of particles. Fine particles Three samples in accordance with the above mentioned guideline. 12:00 till 12:45 o clock Lunch break. 12:45 till 16:00 o clock Determination of the fine particles content by isokinetic extraction of sample volumes containing the dust to be determined, done according to Guideline VDI 2066, Sheet 1 November 2006, "Measuring of particles. Fine particles Three samples in accordance with the above mentioned Guideline, Dismantling of the measurement equipment. 16:00 till 16:30 o clock Final meeting and end of the interlaboratory
Hessian Agency for the Environment and Geology Ludwig-Mond-Straße 33 D-34121 Kassel, Germany. Department I3 (Air Pollution, Emission)
page 1 of 11 Hessian Agency for the Environment and Geology Ludwig-Mond-Straße 33 D-34121 Kassel, Germany Editor German version: I3-Wi Status German version: 30.10.2014 Editor English translation: I3-Co
More informationHESSISCHES LANDESAMT FÜR UMWELT UND GEOLOGIE (HESSIAN STATE OFFICE FOR ENVIRONMENT AND GEOLOGY)
!!"!!#$!!%!!!"$ 1 Introduction The Emission Simulation Facility (abbreviated to ESA) is a development of the former Hessische Landesanstalt für Umwelt (HLfU=Hessian State Institute for Environment), now
More informationThe Question of Homogeneity inside a Chimney: Application of ISO 13528 to Stack Emission Proficiency Tests
Hessian Agency for the Environment and Geology Department I3 Air Pollution, Emission Jens Cordes Benno Stoffels Dominik Wildanger The Question of Homogeneity inside a Chimney: Application of ISO 13528
More informationSpecifications for Proficiency Tests of Facilities According to 26 BImSchG (Gaseous Emission Components)
Page 1 of 16 Specifications for Proficiency Tests of Facilities According to 26 BImSchG (Gaseous Emission Components) [Durchführungsbestimmungen für Ringversuche von 26-Stellen (gasförmige Emissionskomponenten)]
More informationSpecifications for the interlaboratory testing of 26 sites (gaseous emission components) Status June 2007
Page 1 of 20 Specifications for the interlaboratory testing of 26 sites (gaseous emission components) Status June 2007 1 General 1.1 Aim of testing and basis The aim of interlaboratory testing is a quality
More informationGuido Baum Phone: +49(0)221-806 2592 Mail: guido.baum@de.tuv.com www.qal1.de
Determination of CO 2 and N 2 O emissions with CEM Systems within the scope of greenhouse gas trading CEM 2014 Istanbul Thursday, 15 th May 2014 TÜV Rheinland Energie und Umwelt GmbH Guido Baum Phone:
More informationHolcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants
Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants Version 2004-01 / August 2004 (HGRS-JW-04-25s) HGRS-CTS/MT J. Waltisberg SUMMARY ( ) shall not
More information1.0 What Are the Purpose and Applicability of Performance Specification 11?
While we have taken steps to ensure the accuracy of this Internet version of the document, it is not the official version. Please refer to the official version in the FR publication, which appears on the
More informationMethod 202 Dry Impinger Method for Determining Condensable Particulate Emissions from Stationary Sources. By: Paul Ottenstein
Air Quality Issues in the Rocky Mountain Region PM2.5 Source Testing Method 201A Determination PM 10 and PM 2.5 Emissions from Stationary Sources (Constant Sampling Rate Procedure) Method 202 Dry Impinger
More informationSludge Treatment Facility Stack Gas Monitoring Report February 2016
I. INTRODUCTION This Monthly Report aims to provide a summary of environmental performance of the Sludge Treatment Facility (STF) over the monitoring period, which includes the air emission data collected
More informationCertificate: 0000040216 / 29 April 2014
Test report: 936/21209885/G of 20 September 2013 Initial certification: 01 April 2014 Date of expiry: 31 March 2019 Publication: BAnz AT 01 April 2014 B12, chapter IV, No. 7.3 Approved application The
More informationTEST REPORT 26 October, 2005 Page 1 of 8
TEST REPORT 26 October, 2005 Page 1 of 8 ANADOLU KİMYA S.S. Bakır ve Pirinç San. Sit. Leylak Cad. No:15 Beylikduzu/İstanbul FAX NO: 0 212 875 08 22 For the attention of Gurkan Kaya(arge@anadolukimya.com)
More informationTEST REPORT Job No./Report No TR617473 Date:12 June 2014 Page 1 of 5
TEST REPORT Job No./Report No TR617473 Date:12 June 2014 Page 1 of 5 ESEN MIKRONIZE MADEN SAN VE TIC AŞ TEPEÖREN MAH ÖZVATAN CAD NO 5 34959 TUZLA İSTANBUL TEL: 02163041263 FAX: 02163041589 To the attention
More informationExamination syllabuses for Manual Stack emissions monitoring. Environment Agency Version 9 January 2015
Examination syllabuses for Manual Stack emissions monitoring Environment Agency Version 9 January 2015 Record of amendments Version Date Section Amendment number 6 August 09 Level 1 Updated Level 1 syllabus
More informationEN 15267 Type Approval & Certification of AMS (QAL1)
EN 15267 Type Approval & Certification of AMS (QAL1) Mr. Karsten Pletscher TÜV Rheinland Energie und Umwelt GmbH Am Grauen Stein, 51105 Cologne Germany Phone: ++49 221 806 2592 karsten.pletscher@de.tuv.com
More informationThe laboratory fulfils the requirements for periodic emission measurement according to ČSN P CEN/TS 15675:2009
Page 1 of 8 Testing laboratory working site: Working place 1: Technické služby ochrany ovzduší Praha a.s. Testing Laboratory for Measuring Pollutants, Jenečská 146/44, 161 00 Praha Working place 3: Organizational
More informationSpetec. Laminar Flow Box. Portable Clean Room Technology
Spetec Laminar Flow Box Portable Clean Room Technology 1 Fundamentals Portable Clean Room Technology Laminar Flow The basis for the development of the clean room technology was first established in the
More informationEmission inventory system in Latvia
Emission inventory system in Latvia Agita Gancone Latvian Environment, Geology and Meteorology Centre 28-29 September, Ankara Content Some information about Latvia, Legal background; Roles; Resources;
More informationThe ECN Concept for Quality Assurance of Compost
The ECN Concept for Quality Assurance of Compost The ECN Quality Assurance Scheme 1 Targets and Structure of ECN-QAS 2 Quality Assurance Organisations 3 The ECN-QAS for Compost The ECN - Quality Assurance
More informationCERTIFICATE of Product Conformity (QAL1 )
ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000043528 Certified AMS: Manufacturer: Test lnstitute: F-701-20 for particulate matter PMio DURAG GmbH Kollaustraße
More informationStack Sampling Stack sampling or source sampling
Stack Monitoring Stack Sampling Stack sampling or source sampling may be defined as a method of collecting representative samples of pollutant laden air/gases at the place of origin of pollutants to determine
More informationSafety Data Sheet Aluminium profiles Apply for alloys Sapa EN AW 6060, 6063, 6005, 6005A, 6082, yellow chromated, with or without powder coating.
Apply for alloys Sapa EN AW 6060, 6063, 6005, 6005A, 6082, yellow chromated, with or without powder coating. 1. Identification of the Substance/Preparation and Company Product name: (Alloys, Sapa EN AW
More informationCALL FOR OFFER. Győr Distillery Co. Ltd. (H-9027 Győr, Budai u. 7.) hereinafter referred to as Investor calls for offers in subject matter below
CALL FOR OFFER Győr Distillery Co. Ltd. (H-9027 Győr, Budai u. 7.) hereinafter referred to as Investor calls for offers in subject matter below Investor: Győr Distillery Co. Ltd. 9027 Győr, Budai u. 7.
More informationRapid Thermophilic Digestion Technology
Rapid Thermophilic Digestion Technology Biomax Technologies Pte Ltd Mr Sim Eng Tong, CEO Block 4 Kaki Bukit Avenue 1, #05-07/08, Singapore 417939 Phone: + 65 6274 8606 Fax: + 65 6274 8607 Website: www.biomaxtech.com
More informationGuidance and Reporting Instructions on Temporary E-reporting for the MATS Rule
Guidance and Reporting Instructions on Temporary E-reporting for the MATS Rule As explained in the interim MATS e-reporting rule, which was signed by the Administrator on March 9, 2015, the EPA plans to
More informationTÜV RHEINLAND ENERGIE UND UMWELT GMBH
TÜV RHEINLAND ENERGIE UND UMWELT GMBH Report on performance testing of the Air Pollution Monitor 2 (APM-2) measuring system manufactured by Comde-Derenda GmbH for the components suspended particulate matter
More informationCertificate: 0000038506_01 / 29 April 2014
Test report: 936/21219899/C of 30 August 2013 Initial certification: 23 July 2013 Expiry date: 22 July 2018 Publication: BAnz AT 01 April 2014 B12, chapter II, No. 1.1 Approved application The tested AMS
More informationCertificate: 0000040200 / 29 April 2014
Test report: 936/21218490/A of 02 December 2013 Initial certification: 01 April 2014 Expiry date: 31 March 2019 Publication: BAnz AT 01 April 2014 B12, chapter II, No. 2.3 Approved application The tested
More informationCertificate: 0000040200_01 / 9 September 2014
Test report: 936/21218490/B of 28 March 2014 Initial certification: 1 April 2014 Expiry date: 31 March 2019 Publication: BAnz AT 5 August 2014 B11, chapter II, no. 1.1 Approved application The tested AMS
More informationMarsa Thermal Treatment Facility Yearly Emissions Statement
Marsa Thermal Treatment Facility Yearly Emissions Statement Declaration Period: 2009 FACILITY DETAILS IPPC permit number: IP 0004/07 Name of the facility: MARSA THERMAL TREATMENT FACILITY Street address:
More informationRecommendations Regarding the Handling of Norit GL 50 in Flue Gas Clean up Systems
Technical Bulletin Gas & Air Recommendations Regarding the Handling of Norit GL 50 in Flue Gas Clean up Systems 1. Introduction Norit GL 50 is a powdered activated carbon widely used for the removal of
More informationA GUIDANCE NOTE ON THE BEST PRACTICABLE MEANS FOR ELECTRICITY WORKS BPM 7/1 (2014)
A GUIDANCE NOTE ON THE BEST PRACTICABLE MEANS FOR ELECTRICITY WORKS (COAL-FIRED PLANT, GAS-FIRED GAS TURBINE, AND OIL-FIRED GAS TURBINE (PEAK LOPPING PLANT)) BPM 7/1 (2014) Environmental Protection Department
More informationPerformance Standards and Test Procedures for Automated Dust Arrestment-Plant Monitors
Performance Standards and Test Procedures for Automated Dust Arrestment-Plant Monitors Certification under MCERTS according to EN 15859 Environment Agency Version 1 August 2010 Record of amendments Version
More informationAir Quality Performance Test Guidelines. Kansas Department of Health and Environment Bureau of Air and Radiation
Air Quality Performance Test Guidelines Kansas Department of Health and Environment Bureau of Air and Radiation December 22, 2004 TABLE OF CONTENTS 1. INTRODUCTION 2. TEST PLANNING 2.1 EPA Test Methods
More informationScientific and analytical consultancy services for industry
Scientific and analytical consultancy services for industry EXPERTISE ON SITE AND IN THE LABORATORY Anchem Laboratories is a multi-disciplined accredited Laboratory offering a range of specialised environmental
More informationThe Finnish Classification of Indoor Environment and Material Emissions
The Finnish Classification of Indoor Environment and Material Emissions Jorma Säteri Finnish Society of Indoor Air Quality and Climate, FiSIAQ Finnish Classification of Indoor Environment 2008 An update
More informationCERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: 0000034862. Gaschromategraph GC 5000 BTX Type FID for Benzene
Umwelt Bundes Amt ror our Environ ment /;;!.. TÜVRheinland Precisely Right. CERTIFICATE on Product Conformity (QAL 1) Number of Certificate: 0000034862 Certified AMS: Manufacturer: Test Institute: Gaschromategraph
More informationSpetec. Clean room. technology. Laminar flow box Clean room workbench CleanBoy Clean room cell Service, certification
Spetec Clean room technology Laminar flow box Clean room workbench CleanBoy Clean room cell Service, certification 1 Product overview PBS, FMS, and FBS series device families feature a modular design,
More informationParticle testing in cleanroom high-pressure gas lines to ISO 14644 made easy with the MET ONE 3400 gas calibrations
Particle testing in cleanroom high-pressure gas lines to ISO 14644 made easy with the MET ONE 3400 gas calibrations B e c k m a n C o u l t e r L i f e S c i e n c e s 2 5 0 S. K r a e m e r B o u l e
More informationSANEM MATBAACILIK VE ULUSLARARASI TAŞ A.Ş.
TEST REPOR Page 1 of 7 REPORT NUMBER : APPLICANT NAME ADDRESS SAMPLE DESCRIPTION : BUYER : TURA110081714 SANEM MATBAACILIK VE ULUSLARARASI TAŞ A.Ş. Başkent Organize Sanayi Bölgesi 19 C No: 85 Maliköy Temelli
More informationClimate modelling. Dr. Heike Huebener Hessian Agency for Environment and Geology Hessian Centre on Climate Change
Hessisches Landesamt für Umwelt und Geologie Climate modelling Dr. Heike Huebener Hessian Agency for Environment and Geology Hessian Centre on Climate Change Climate: Definition Weather: momentary state
More informationAny potential user should ensure in consultation with the manufacturer that this AMS is suitable for the installation on which it will be installed.
Test report: 936/21210692/A of 30 March 2011 First certification: 29 July 2011 Run of validity until: 28 July 2016 Publication BAnz. 29 July 2011, No 113, page 2725, chapter I, No 4.1 Authorised application
More informationThe question of homogeneity inside a chimney: application of ISO 13528 to stack emission proficiency tests
Accred Qual Assur (05) 0:87 95 DOI 0007/s00769-05-9-y PRACTITIONER S REPORT The question of homogeneity inside a chimney: application of ISO 58 to stack emission proficiency tests Jens Cordes Benno Stoffels
More informationHow To Run A Power Plant In Celje
VRANSKO, May 2009 Waste Management Strategy Waste management strategy in accordance with European directive 91/156/EEC: 1. Reduction at source 2. Reuse 3. Recycle 4. Energy recovery 5.Disposal Celje Regional
More informationSven Rentschler, CEO and greatgrandson of the company founder Gustav Rentschler. Clean air in industry is our core competence
Sven Rentschler, CEO and greatgrandson of the company founder Gustav Rentschler Clean air in industry is our core competence 6 Welcome to REVEN REVEN = REntschler VENtilation On the basis of decades of
More informationManual stack emission monitoring Performance standard for organisations. Environment Agency November 2011 Version 7.2
Manual stack emission monitoring Performance standard for organisations Environment Agency November 2011 Version 7.2 Record of amendments Version Date Section Amendment number 7.1 Jan 11 5.6.8 Added requirement
More informationAny potential user should ensure in consultation with the manufacturer that this AMS is suitable for the installation on which it will be installed.
Test report: 936/21206693/B of 28 March 2011 First certification: 29 July 2011 Run of validity until: 28 July 2016 Publication BAnz. 29 July 2011, No 113, page 2725, chapter I, No 4.2 Authorised application
More informationSERIES KS-701+KS-306.50-WI
SERIES KS-701+KS-306.50-WI EIGHT-STAGE CASCAD IMPACTOR WITH BACKUP FILTER FOR THE FRACTIONATED SAMPLING OF SOLID PARTICLES AND AEROSOLES Eight impactor stages. SPECIAL FEATURES Rapidly changeable impactor
More informationImpact of utilised bottom ash
Impact of utilised bottom ash Raul Grönholm, MSc, Sysav Jan Hartlén, PhD, JH Geoconsulting 24 januari 2012 1 Agenda SYSAV BOTTOM ASH FROM WASTE INCINERATION USE OF BOTTOM ASH MONITORING AND ESTIMATION
More informationCertificate: 0000038506 / 20 August 2013
Test report: 936/21219899/B of 28 March 2013 Initial certification: 23 July 2013 Expiry date: 22 July 2018 Publication: BAnz AT 23 July 2013 B4, chapter II, No. 1.1 Approved application The tested AMS
More informationSUS. Company Profile. Ulrich Nell, Feldstr.23, D - 46149 Oberhausen, Tel. 0049(0)208/658535 Fax 0049(0)208/658536
SUS Ulrich Nell, Feldstr.23, D - 46149 Oberhausen, Tel. 0049(0208/658535 Fax 0049(0208/658536 Company Profile SUS was founded in 1986 in Oberhausen in the Ruhr area (close to Düsseldorf, in order to meet
More informationHEPA FILTER DEFECTS ARE COMMON
HEPA FILTER DEFECTS ARE COMMON Kenneth F. Cherry 1 and Kenneth A. Smigielski 2 1 NCEC Inc. 2 First Solar LLC. ABSTRACT HEPA filters (High Efficiency Particulate Air) filters are claimed by vendors to have
More informationVZ/VZM SERIES Heavy Duty Shredders 600-2,100 kg/h
VZ/VZM SERIES Heavy Duty Shredders 600-2,100 kg/h Technical Specifications VZ/VZM SERIES Heavy Duty Shredders VZ 17.00 / VZ 18.00 Inline set-up VZM 17.00 / VZM 18.00 Inline set-up Technical Data VZ/VZM
More informationSize Segregated Characterisation of Main Components in Kerbside Particulates in Dresden, Germany
Saxon State Agency for Environment and Geology Size Segregated Characterisation of Main Components in Kerbside Particulates in Dresden, Germany Holger Gerwig 1, Erika Brüggemann 2, Thomas Gnauk 2, Konrad
More informationAssessment of Chemical analytical laboratories in Bishkek, Kyrgyzstan
Assessment of Chemical analytical laboratories in Bishkek, Kyrgyzstan INDEX 1. Introduction... 2 2. Central Laboratory on the State agency on Geology... 4 2.1 Equipment... 4 2.2 Personnel... 4 2.3 Quality
More informationTesting guideline. "special protected vehicles"
"" ( Sondergeschützte Fahrzeuge ) bullet resistance Englische Übersetzung; es gilt immer die deutsche Originalfassung! English translation; however the original German version always prevails! Publisher:
More informationRevealing the costs of air pollution from industrial facilities in Europe a summary for policymakers
Revealing the costs of air pollution from industrial facilities in Europe a summary for policymakers A new European Environment Agency (EEA report, Revealing the costs of air pollution from industrial
More informationAssembly of LPCC Packages AN-0001
Assembly of LPCC Packages AN-0001 Surface Mount Assembly and Handling of ANADIGICS LPCC Packages 1.0 Overview ANADIGICS power amplifiers are typically packaged in a Leadless Plastic Chip Carrier (LPCC)
More informationM.Sc. Matti Kivelä Power Plant Manager R&D Lahti Energia Oy P.O. Box 93 FIN-15141 Lahti Finland Tel. 358 3 823 3240 matti.kivela@lahtienergia.
LAHTI ENERGIA OY M.Sc. Matti Kivelä Power Plant Manager R&D Lahti Energia Oy P.O. Box 93 FIN-15141 Lahti Finland Tel. 358 3 823 3240 matti.kivela@lahtienergia.fi Contact LAHTI ENERGIA OY Founded. 1907
More informationANALYTICAL REPORT LABORATORY DETAILS. Telephone Facsimile Email. SGS Reference Report Number Date Reported Date Received
ANALYTICAL REPORT CLIENT DETAILS Contact Client Address Matthew Behre SGS Metallurgical Services 431 Victoria Street Malaga MALAGA WA 6090 LABORATORY DETAILS Manager Laboratory Address Said Hirad SGS Newburn
More informationAir Pollution Prevention Manual on Emission Monitoring
Texte 06 08 Air Pollution Prevention Manual on Emission Monitoring ISSN 1862-4804 TEXTE ENVIRONMENTAL RESEARCH OF THE FEDERAL MINISTRY OF THE ENVIRONMENT, NATURE CONSERVATION AND NUCLEAR SAFETY Research
More informationSpetec Laminar Flow Systems. Operating Instructions
Spetec Laminar Flow Systems Operating Instructions 1 Spetec Laminar Flow Systems Operating Instructions Thank you for your trust in the Spetec clean room systems! Your chosen system is ideally suited for
More informationUniversal Data Acquisition (UDA)
Universal Data Acquisition (UDA) I C P - O P T I C A L E M I S S I O N P R O D U C T N O T E Introduction Historically, Inductively Coupled Plasma (ICP) spectroscopy has been used for multiple analyte
More informationUK Air Quality Monitoring Networks
UK Air Quality Monitoring Networks Steve Telling 28 August 2012 Introduction History of air quality monitoring Legislative drivers The monitoring networks Data quality considerations Access to data Concern
More informationColorants for Plastics are our Playground PRODUCT STEWARDSHIP: ONE STEP AHEAD WITH CLARIANT
Colorants for Plastics are our Playground PRODUCT STEWARDSHIP: ONE STEP AHEAD WITH CLARIANT Public Colorants for plastics Business Unit Pigments 2 Public, Colorants for Plastics are our Playground Table
More informationPolicy on Monitoring of Stack Emissions to Air at EPA Licensed Sites
Policy on Monitoring of Stack Emissions to Air at EPA Licensed Sites 1. OVERVIEW In Ireland at present there are no mandatory minimum criteria specified in relation to the completion of stationary source
More information47374_04_p25-32.qxd 2/9/07 7:50 AM Page 25. 4 Atoms and Elements
47374_04_p25-32.qxd 2/9/07 7:50 AM Page 25 4 Atoms and Elements 4.1 a. Cu b. Si c. K d. N e. Fe f. Ba g. Pb h. Sr 4.2 a. O b. Li c. S d. Al e. H f. Ne g. Sn h. Au 4.3 a. carbon b. chlorine c. iodine d.
More informationVdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
More informationThis example of a completed sampling plan worksheet has been included to illustrate the information
APPENDIX B EXAMPLE OF A COMPLETED SAMPLING PLAN WORKSHEET This example of a completed sampling plan worksheet has been included to illustrate the information necessary to document a sampling program for
More informationATMOSPHERIC EMISSIONS FROM GAS FIRED HOME HEATING APPLIANCES
ATMOSPHERIC EMISSIONS FROM GAS FIRED HOME HEATING APPLIANCES Stefano Cernuschi, Stefano Consonni, Giovanni Lonati, Michele Giugliano, Senem Ozgen DIIAR Environmental Sect., Politecnico di Milano, P.za
More informationToyota commercialises its first diesel hybrid
Toyota commercialises its first diesel hybrid Toyota Dyna is now the cleanest diesel commercial vehicle of its type In September 2003, Toyota introduced the Toyota Dyna Hybrid in Japan. This makes Dyna
More informationGUIDELINES ON SAMPLING STRATEGY AND SUBMISSION OF AIR MONITORING / SAMPLE ANALYSIS REPORT
GUIDELINES ON SAMPLING STRATEGY AND SUBMISSION OF AIR MONITORING / SAMPLE ANALYSIS REPORT MINISTRY OF MANPOWER OCCUPATIONAL HEALTH DEPARTMENT 18 HAVELOCK ROAD #05-01 SINGAPORE 059764 FAX: 539 5140 EMAIL:
More informationCompliant Terminal Technology Summary Test Report
Engineering Report ER04100 October 5th, 2004 Revision A Copyright Autosplice Inc., September 2004 Table of Contents Summary Overview 3 Compliant Terminal Specifications 3 Test Plan 4 Test Conditions 4
More informationREPORT 23/12/2011 N DRC-11-119507-08855B
REPORT 23/12/2011 N DRC-11-119507-08855B Analytical Proficiency Tests relating to measurements of hydrochloric acid, hydrofluoric acid, ammonia, sulphur dioxide, mercury, and metals (and metalloids) in
More informationWaste to Energy in Düsseldorf. for a clean city.
Waste to Energy in Düsseldorf for a clean city. Waste Management in Düsseldorf. Düsseldorf s public utilities company known as Stadtwerke Düsseldorf operates a waste to energy plant (WtE) that has been
More informationTownsville Dust Monitoring Program. March 2008 to December 2009
Townsville Dust Monitoring Program March 2008 to December 2009 Prepared by: Air Quality Sciences Department of Environment and Resource Management State of Queensland (Department of Environment and Resource
More informationRoHS Test Methods. Presented by: Bruce Peterson
RoHS Test Methods Presented by: Bruce Peterson Motivation for Presentation The EU RoHS directive takes effect July 1, 2006 Customer confusion about - Scope of directive How much testing needs to be performed
More informationMini slide, Series MSN narrow version Ø 6-16 mm double-acting with magnetic piston cushioning: elastic with integrated ball rail guide
Piston rod cylinder uide cylinders ini slide, Series SN 1 Ambient temperature min./max. +0 C / +60 C edium Compressed air ax. particle size 5 µm Oil content of compressed air 0 mg/m³ - 1 mg/m³ Pressure
More informationTest Report No. 2141788/SD Date : Nov 03 2011 Page 1 of 5
Test Report No. 24788/SD Date : Nov 03 20 Page of 5 ECOTANKA GLOBAL HK LIMITED NO. 2- WEST LAKE ROAD XICHENG STREET YONGKANG CITY CHINA The following samples were submitted and identified on behalf of
More informationSPECIAL APPLICATIONS
Page 1 SPECIAL APPLICATIONS The protection of microelectronics clean rooms using aspirating smoke detection systems requires special consideration. The physical configuration of the room(s) and the direction
More informationS300 Series Dust Monitors
S301 DustGuard S303 Trend Monitor S304 Emission Monitor S305 Stack Monitor Intrinsically Safe (ATEX) Dust Monitors Split Architecture (Remote)Models Data Logging Software S300 Series Dust Monitors Dust
More informationLASER CUTTING OF STAINLESS STEEL
LASER CUTTING OF STAINLESS STEEL Laser inert gas cutting is the most applicable process type used for cutting of stainless steel. Laser oxygen cutting is also applied in cases where the cut face oxidation
More informationSecondary Lead Smelting
Secondary Lead Smelting Secondary Lead Smelting Objectives Describe the basic smelting process terms: smelting, refining, and alloying List key chemicals associated with secondary lead smelting Define
More informationU11 Boys Black March 21st Monday 6:00-7:30 p.m. Damien Training Field 2 March 24th Thursday 4:30-6:00 p.m. Damien Training Field 2 March 28th Monday 6
U11 Boys Navy March 21st Monday 4:30-6:00 p.m. Damien Training Field 2 March 24th Thursday 6:00-7:30 p.m. Damien Training Field 2 March 28th Monday 4:30-6:00 p.m. Damien Training Field 2 March 31st Thursday
More informationTEST REPORT Job No./Report No TR699846 Date:5 January 2015 Page 1 of 11
TEST REPORT Job No./Report No TR699846 Date:5 January 2015 Page 1 of 11 DIOR İÇ VE DIŞ TIC LTD ŞTI 29 EKIM CD VIZYON PRK MERKEZ PLZ C2 BLOK KT:8 NO:244-245 YENIBOSN BHÇELIEVLER İSTNBUL TEL: 02125037780
More informationMonitoring Ground Vibration arising from Piling and Civil Engineering Projects
Monitoring Ground Vibration arising from Piling and Civil Engineering Projects By Andy Maslin of Accudata Limited May 2004 (Revised May 2015) 1. Introduction 2. Units of Measurement 3. Instrumentation
More informationThe Introduction of Euro IV and Euro V Emissions Directive for Heavy Vehicles
The Introduction of Euro IV and Euro V Emissions Directive for Heavy Vehicles Introduction As a member of the European Union, Ireland is obliged to introduce Directive 2005/55/EC. Directive 2005/55/EC
More informationGasförmige und flüssige synthetische Energieträger aus Biomasse Stand der Entwicklungen an der TU Wien. Hermann HOFBAUER, TU Wien
Gasförmige und flüssige synthetische Energieträger aus Biomasse Stand der Entwicklungen an der TU Wien Hermann HOFBAUER, TU Wien Fundamental Idea biogas plant gasification product synthesis gasification
More informationWood burning for cooking: Evaluation of improved stoves in Mexico
Wood burning for cooking: Evaluation of improved stoves in Mexico Expert meeting to further develop the Standardized Toolkit for Identification and Quantification of Dioxin and Furan releases Geneva, Switzerland,
More informationCertificate: 0000040211 / 29 April 2014
Test report: 936/21219690/A of 10 October 2013 Initial certification: 01 April 2014 Expiry date: 31 March 2019 Publication: BAnz AT 01 April 2014 B12, chapter II, No. 2.2 Approved application The tested
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD. 4/F, Building #3 Runheng Electronic Park Luxian Road 2 nd Road, Xin an Street, Bao an District Shenzhen City,
More informationThe Introduction of Euro 5 and Euro 6 Emissions Regulations for Light Passenger and Commercial Vehicles
The Introduction of Euro 5 and Euro 6 Emissions Regulations for Light Passenger and Commercial Vehicles Introduction As a member of the European Union, Ireland is obliged to introduce Regulation (EC) No.
More informationCL90i. 77-021 Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser
3 - Beam Self-Leveling Cross Line Laser CL90i 77-01 Please read these instructions before operating the product Self-Leveling GB D F I E PT NL DK SE FIN NO PL GR CZ RU HU SK SI BG RO EE LV LT Contents
More informationPM Fine Database and Associated Visualization Tool
PM Fine Database and Associated Visualization Tool Steven Boone Director of Information Technology E. H. Pechan and Associates, Inc. 3622 Lyckan Parkway, Suite 2002; Durham, North Carolina 27707; 919-493-3144
More informationPresentation of the Kompostgüteverband Österreich
Presentation of the Kompostgüteverband Österreich 6.11.2014 Contents Presentation of the Kompostgüteverband Österreich... 1 1. Quality Assurance Organisation... 2 Board of Directors... 3 Quality-label
More informationResearch Project F 2071. W. Richter. Manual of thermal comfort of Summer cooling mode
Research Project F 2071 W. Richter Manual of thermal comfort of Summer cooling mode Dortmund/Berlin/Dresden 2007 This publication is a summary of the final report of a project Development of a manual on
More informationMODEL KS-303.150.10/2,5/1
MODEL HIGH VOLUME FLOW CONTINUOUS SAMPLER FOR AIRBORNE DUSTS AND AEROSOLS, WITH PM 10 / PM 2,5 / PM 1 BY OPERATION OVER 24 HOURS, FOR MEASUREMENT OF IMISSION BY ANY EQUIPMENT, OR FOR WORKING PLACE AREA,
More informationCertificate: 0000039318 / 20 August 2013
Test report: 936/21220824/B of 15 March 2013 Initial certification: 23 July 2013 Expiry date: 22 July 2018 Publication: BAnz AT 23 July 2013 B4, chapter II, No. 2.3 Approved application The tested AMS
More informationExample a. Notification of Compliance Status
Notification of Compliance Status National Emission Standards for Hazardous Air Pollutants: Area Source Standards for Nine Metal Fabrication and Finishing Source Categories 40 CFR 63 subpart XXXXXX Section
More informationMonitoring of air pollution spread on the car-free day in the city of Veszprém
INTERNATIONAL JOURNAL OF ENERGY AND ENVIRONMENT Volume 5, Issue 6, 2014 pp.679-684 Journal homepage: www.ijee.ieefoundation.org Monitoring of air pollution spread on the car-free day in the city of Veszprém
More information