Flue Damper Electronic Ignition Models

Size: px
Start display at page:

Download "Flue Damper Electronic Ignition Models"

Transcription

1 COMMERCIAL GAS REPLACEMENT PARTS LIST Flue Damper Electronic Ignition Models Includes Hydrojet Total Performance System Effective: November, 2012 ECO 7800 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING REPLACEMENT PARTS Dimensions and specifications subject to change without notice. Parts Book # F

2 Page 2 Page 2

3 Item Description Model Model Model Model Model D38T155(E)*(N,X) D65T370(E)*(N,X)(A) D65T399(E)*N(A) D75T125(E)*(N,X) D75T160(E)*(N,X) 1 Draft Diverter Complete with Leg Kit Draft Diverter Only Draft Diverter Leg Kit Only Flue Damper Reducer Flue Damper Complete Hot Water Outlet Nipple (Top) Cold Water Inlet Diptube (Top) Plug Type Anode Rod (Magnesium) (Qty. 3) (Qty. 3) (Qty. 3) (Qty. 2) (Qty. 2) Plug Type Anode Rod (Aluminum) (Qty. 3) (Qty. 3) (Qty. 3) (Qty. 2) (Qty. 2) Plug Type Anode Rod (A420 Aluminum)# (Qty. 3) (Qty. 3) (Qty. 3) (Qty. 2) (Qty. 2) 9 Flue Baffle (Qty. 11) (Qty.16) (Qty.16) Flue Core (Qty. 2) A Flue Reducer ASSE Approved Mixing Valve (Optional) Upper Thermostat Sensor Hot Water Outlet Nipple (Side) " NPT to 3/4" NPT Reducer Bushing /4" NPT Nipple " NPT Nipple T&P Valve Utility Cover Lower Thermostat Well Clip for Lower Thermostat Lower Thermostat Sensor Control Box Assembly SEE PAGE 7 SEE PAGE 7 SEE PAGE 7 SEE PAGE 7 SEE PAGE 7 22 Cold Water Inlet Diptube (Side) Brass Drain Valve Cleanout O-Ring Gasket A Cleanout Gasket (ASME) Cleanout Cover A Cleanout Cover (ASME) Cleanout Cover Screw (Qty. 6) (Qty. 6) (Qty. 6) (Qty. 6) (Qty. 6) 26A Cleanout Cover Screw (ASME) (Qty. 6) (Qty. 6) Cleanout Access Cover Pipe plug (3/4 NPT) * Applies to all warranties Applies when "E" is present in model ** Ordering a complete burner rack may increase number (Example: D38T155E3N). delivery time. Please order the specific 1 For serial numbers PRIOR to GB component required for the quickest delivery. 2 For serial numbers AFTER and including GB *** No LP version model available. 3 For serial numbers PRIOR to HA **** No Low Nox versions available over 400K btuh. 4 For serial numbers including and AFTER HA # A420 Anode may need to be cut to length Page 3

4 Page 4 Page 4

5 Item Description Model Model Model Model Model D38T155(E)*(N,X) D65T370(E)*(N,X)(A) D65T399(E)*N(A) D75T125(E)*(N,X) D75T160(E)*(N,X) 29 Burner Rack Complete (Natural Gas) ** Burner Rack Complete (Nat. Gas)(Lo NOX) ** Burner Rack Complete (LP Gas) ** *** Burner Rack Only Gas Valve (Natural Gas) Gas Valve (LP Gas) *** Burner Tube (Standard) (Qty. 5) (Qty. 9) (Qty. 9) (Qty. 3) (Qty. 5) Burner Tube (Lo-NOX) (Qty. 5) (Qty. 9) (Qty. 9) (Qty. 3) (Qty. 5) Burner Tube (Stainless Steel) (Qty. 5) (Qty. 9) (Qty. 9) (Qty. 3) (Qty. 5) 33 Burner Manifold (Nat gas) Burner Manifold (LP gas) *** A Burner Manifold (Nat gas) Burner Manifold (LP gas) *** B Burner Manifold (Nat gas) Main Burner Orifice (Natural Gas) (0ft to 2000ft) (Qty. 5) (Qty. 9) (Qty. 9) (Qty. 3) (Qty. 5) High Altitude (Natural Gas) (2001ft to 5000ft) (Qty. 5) (Qty. 9) (Qty. 9) (Qty. 3) (Qty. 5) High Altitude (Natural Gas) (5001ft to 8000ft) (Qty. 5) (Qty. 9) (Qty. 9) (Qty. 3) (Qty. 5) High Altitude (Natural Gas) (8001ft & above) (Qty. 5) (Qty. 9) (Qty. 9) (Qty. 3) (Qty. 5) Main Burner Orifice (LP Gas) (0ft to 2000ft) (Qty. 5) (Qty. 9) *** (Qty. 3) (Qty. 5) High Altitude (LP Gas) (2001ft to 5000ft) /16 (Qty. 5) (Qty. 9) *** (Qty. 3) /16 (Qty. 5) High Altitude (LP Gas) (5001ft to 8000ft) (Qty. 5) (Qty. 9) *** (Qty. 3) (Qty. 5) High Altitude (LP Gas) (8001ft & above) (Qty. 5) (Qty. 9) *** (Qty. 3) (Qty. 5) 35 Pilot Shield Pilot Assembly (Natural Gas) Pilot Assembly (LP Gas) Pilot Orifice (Natural Gas) Pilot Orifice (LP Gas) Aluminum Pilot Tube Burner Support Draft Panel Pilot Mounting Screw (Qty. 2) (Qty. 2) (Qty. 2) (Qty. 2) (Qty. 2) 42 Sreet Elbow 1" NPT (Nat.) *** Pipe Nipple 1" NPT (Nat.) *** Elbow 1" NPT (Nat.) *** Gas Support Bracket (Nat.) Gas Support Bracket (LP) *** 46 Ground Wire LP to Natural Gas Conversion Kit *** * Applies to all warranties Applies when "E" is present in model ** Ordering a complete burner rack may increase number (Example: D38T155E3N). delivery time. Please order the specific 1 For serial numbers PRIOR to GB component required for the quickest delivery. 2 For serial numbers AFTER and including GB *** No LP version model available. 3 For serial numbers PRIOR to HA **** No Low Nox versions available over 400K btuh. 4 For serial numbers including and AFTER HA # A420 Anode may need to be cut to length Page 5

6 Page 6 Page 6

7 Item Description Model Model Model Model Model D38T155(E)*(N,X) D65T370(E)*(N,X)(A) D65T399(E)*N(A) D75T125(E)*(N,X) D75T160(E)*(N,X) 21 Control Box Assembly (Dual Sensor) Control Box Assembly (Single Sensor) Control Box Cover Assembly Screw #8-18 X 3/4 Pan Head CR Honeywell Temperature Contol Display Control Box Cover Integrated Control Board (Dual Sensor) Integrated Control Board (Single Sensor) Screw #8-18 X 1/2 Pan Head CR Transformer 110V Ground Lug 1/4 x Power On/Off Switch Screw 8/32 X 1/4 Pan Head CR w/adh Primary Transformer Wiring Harness Secondary Transformer Wiring Harness Power Cord Wiring Harness Gas Valve Control Wiring Harness Damper Wiring Harness (Dual Sensor) Damper Wiring Harness (Single Sensor) Display Control Wiring Harness Display Cover Wiring Harness Control Box Panel Strain Relief Bushing 7/8" Snap-in Bushing 7/8" Strain Relief Bushing 1/2" * Applies to all warranties Applies when "E" is present in model ** Ordering a complete burner rack may increase number (Example: D38T155E3N). delivery time. Please order the specific 1 For serial numbers PRIOR to GB component required for the quickest delivery. 2 For serial numbers AFTER and including GB *** No LP version model available. 3 For serial numbers PRIOR to HA **** No Low Nox versions available over 400K btuh. 4 For serial numbers including and AFTER HA # A420 Anode may need to be cut to length Page 7

8 Page 8 Page 8

9 Item Description Model Model Model Model Model D75T300*(N,X)(A) D80L399(E)*(N,X)(A) D80L450*(N,X)(A) D80L505*(N,X)(A) D80T180(E)*(N,X) 1 Draft Diverter Complete with Leg Kit Draft Diverter Only Draft Diverter Leg Kit Only Flue Damper Reducer Flue Damper Complete Hot Water Outlet Nipple (Top) Cold Water Inlet Diptube (Top) Plug Type Anode Rod (Magnesium) (Qty. 3) (Qty. 4) (Qty. 4) (Qty. 4) (Qty. 2) Plug Type Anode Rod (Aluminum) (Qty. 3) (Qty. 4) (Qty. 4) (Qty. 4) (Qty. 2) Plug Type Anode Rod (A420 Aluminum)# (Qty. 3) (Qty. 4) (Qty. 4) (Qty. 4) (Qty. 2) 9 Flue Baffle (Qty. 11) (Qty. 20) (Qty. 20) (Qty. 20) (Qty. 8) 10 Flue Core A Flue Reducer ASSE Approved Mixing Valve (Optional) Upper Thermostat Sensor Hot Water Outlet Nipple (Side) " NPT to 3/4" NPT Reducer Bushing /4" NPT Nipple " NPT Nipple T&P Valve Utility Cover Lower Thermostat Well Clip for Lower Thermostat Lower Thermostat Sensor Control Box Assembly SEE PAGE 13 SEE PAGE 13 SEE PAGE 13 SEE PAGE 13 SEE PAGE Cold Water Inlet Diptube (Side) Brass Drain Valve Cleanout O-Ring Gasket A Cleanout Gasket (ASME) Cleanout Cover A Cleanout Cover (ASME) Cleanout Cover Screw (Qty. 6) (Qty. 6) (Qty. 6) (Qty. 6) (Qty. 6) 26A Cleanout Cover Screw (ASME) (Qty. 6) (Qty. 6) (Qty. 6) (Qty. 6) Cleanout Access Cover Pipe plug (3/4 NPT) * Applies to all warranties Applies when "E" is present in model ** Ordering a complete burner rack may increase number (Example: D38T155E3N). delivery time. Please order the specific 1 For serial numbers PRIOR to GB component required for the quickest delivery. 2 For serial numbers AFTER and including GB *** No LP version model available. 3 For serial numbers PRIOR to HA **** No Low Nox versions available over 400K btuh. 4 For serial numbers including and AFTER HA # A420 Anode may need to be cut to length Page 9

10 Page 10 Page 10

11 Item Description Model Model Model Model Model D75T300*(N,X)(A) D80L399(E)*(N,X)(A) D80L450*(N,X)(A) D80L505*(N,X)(A) D80T180(E)*(N,X) 29 Burner Rack Complete (Natural Gas) ** Burner Rack Complete (Nat. Gas)(Lo NOX) ** ***** ***** Burner Rack Complete (LP Gas) ** Burner Rack Only Gas Valve (Natural Gas) Gas Valve (LP Gas) Burner Tube (Standard) (Qty. 7) (Qty. 9) (Qty. 9) (Qty. 9) (Qty. 5) Burner Tube (Lo-NOX) (Qty. 7) (Qty. 9) ***** (Qty. 9) (Qty. 5) Burner Tube (Stainless Steel) (Qty. 7) (Qty. 9) (Qty. 9) (Qty. 9) (Qty. 5) 33 Burner Manifold (Nat gas) Burner Manifold (LP gas) A Burner Manifold (Nat gas) Burner Manifold (LP gas) B Burner Manifold (Nat gas) Main Burner Orifice (Natural Gas) (0ft to 2000ft) (Qty. 7) (Qty. 9) /8 (Qty. 9) (Qty. 9) (Qty. 5) High Altitude (Natural Gas) (2001ft to 5000ft) (Qty. 7) (Qty. 9) (Qty. 9) /8 (Qty. 9) (Qty. 5) High Altitude (Natural Gas) (5001ft to 8000ft) (Qty. 7) (Qty. 9) (Qty. 9) (Qty. 9) (Qty. 5) High Altitude (Natural Gas) (8001ft & above) (Qty. 7) (Qty. 9) (Qty. 9) (Qty. 9) (Qty. 5) Main Burner Orifice (LP Gas) (0ft to 2000ft) (Qty. 7) (Qty. 9) (Qty. 9) (Qty. 9) (Qty. 5) High Altitude (LP Gas) (2001ft to 5000ft) (Qty. 7) (Qty. 9) (Qty. 9) (Qty. 9) (Qty. 5) High Altitude (LP Gas) (5001ft to 8000ft) (Qty. 7) (Qty. 9) (Qty. 9) (Qty. 9) /16 (Qty. 5) High Altitude (LP Gas) (8001ft & above) (Qty. 7) (Qty. 9) (Qty. 9) (Qty. 9) /16 (Qty. 5) 35 Pilot Shield Pilot Assembly (Natural Gas) Pilot Assembly (LP Gas) Pilot Orifice (Natural Gas) Pilot Orifice (LP Gas) Aluminum Pilot Tube Burner Support Draft Panel Pilot Mounting Screw (Qty. 2) (Qty. 2) (Qty. 2) (Qty. 2) (Qty. 2) 42 Sreet Elbow 1" NPT (Nat.) Pipe Nipple 1" NPT (Nat.) Elbow 1" NPT (Nat.) Gas Support Bracket (Nat.) Gas Support Bracket (LP) Ground Wire LP to Natural Gas Conversion Kit * Applies to all warranties Applies when "E" is present in model ** Ordering a complete burner rack may increase number (Example: D38T155E3N). delivery time. Please order the specific 1 For serial numbers PRIOR to GB component required for the quickest delivery. 2 For serial numbers AFTER and including GB *** No LP version model available. 3 For serial numbers PRIOR to HA # A420 Anode may need to be cut to length 4 For serial numbers including and AFTER HA Page 11

12 Page 12 Page 12

13 Item Description Model Model Model Model Model D75T300*(N,X)(A) D80L399(E)*(N,X)(A) D80L450*(N,X)(A) D80L505*(N,X)(A) D80T180(E)*(N,X) 21 Control Box Assembly (Dual Sensor) Control Box Assembly (Single Sensor) Control Box Cover Assembly Screw #8-18 X 3/4 Pan Head CR Honeywell Temperature Contol Display Control Box Cover Integrated Control Board (Dual Sensor) Integrated Control Board (Single Sensor) Screw #8-18 X 1/2 Pan Head CR Transformer 110V Ground Lug 1/4 x Power On/Off Switch Screw 8/32 X 1/4 Pan Head CR w/adh Primary Transformer Wiring Harness Secondary Transformer Wiring Harness Power Cord Wiring Harness Gas Valve Control Wiring Harness Damper Wiring Harness (Dual Sensor) Damper Wiring Harness (Single Sensor) Display Control Wiring Harness Display Cover Wiring Harness Control Box Panel Strain Relief Bushing 7/8" Snap-in Bushing 7/8" Strain Relief Bushing 1/2" * Applies to all warranties Applies when "E" is present in model ** Ordering a complete burner rack may increase number (Example: D38T155E3N). delivery time. Please order the specific 1 For serial numbers PRIOR to GB component required for the quickest delivery. 2 For serial numbers AFTER and including GB *** No LP version model available. 3 For serial numbers PRIOR to HA **** No Low Nox versions available over 400K btuh. 4 For serial numbers including and AFTER HA # A420 Anode may need to be cut to length Page 13

14 Page 14 Page 14

15 Item Description Model Model Model Model Model D80T199(E)*(N,X) D80T250(E)*(N,X)(A) D80T425*(N,X)(A) D80T505*(N,X)(A) D100L199(E)*(N,X) 1 Draft Diverter Complete with Leg Kit Draft Diverter Only Draft Diverter Leg Kit Only Flue Damper Reducer Flue Damper Complete Hot Water Outlet Nipple (Top) Cold Water Inlet Diptube (Top) Plug Type Anode Rod (Magnesium) (Qty. 2) (Qty. 2) (Qty. 3) (Qty. 3) (Qty. 4) Plug Type Anode Rod (Aluminum) (Qty. 2) (Qty. 2) (Qty. 3) (Qty. 3) (Qty. 4) Plug Type Anode Rod (A420 Aluminum)# (Qty. 2) (Qty. 2) (Qty. 3) (Qty. 3) (Qty. 4) 9 Flue Baffle (Qty. 8) (Qty. 8) (Qty. 16) (Qty. 16) (Qty. 12) 10 Flue Core A Flue Reducer ASSE Approved Mixing Valve (Optional) Upper Thermostat Sensor Hot Water Outlet Nipple (Side) " NPT to 3/4" NPT Reducer Bushing /4" NPT Nipple " NPT Nipple T&P Valve Utility Cover Lower Thermostat Well Clip for Lower Thermostat Lower Thermostat Sensor Control Box Assembly SEE PAGE 19 SEE PAGE 19 SEE PAGE 19 SEE PAGE 19 SEE PAGE Cold Water Inlet Diptube (Side) Brass Drain Valve Cleanout O-Ring Gasket A Cleanout Gasket (ASME) Cleanout Cover A Cleanout Cover (ASME) Cleanout Cover Screw (Qty. 6) (Qty. 6) (Qty. 6) (Qty. 6) (Qty. 6) 26A Cleanout Cover Screw (ASME) (Qty. 6) (Qty. 6) (Qty. 6) Cleanout Access Cover Pipe plug (3/4 NPT) * Applies to all warranties Applies when "E" is present in model ** Ordering a complete burner rack may increase number (Example: D38T155E3N). delivery time. Please order the specific 1 For serial numbers PRIOR to GB component required for the quickest delivery. 2 For serial numbers AFTER and including GB *** No LP version model available. 3 For serial numbers PRIOR to HA **** No Low Nox versions available over 400K btuh. 4 For serial numbers including and AFTER HA # A420 Anode may need to be cut to length Page 15

16 Page 16 Page 16

17 Item Description Model Model Model Model Model D80T199(E)*(N,X) D80T250(E)*(N,X)(A) D80T425*(N,X)(A) D80T505*(N,X)(A) D100L199(E)*(N,X) 29 Burner Rack Complete (Natural Gas) ** Burner Rack Complete (Nat. Gas)(Lo NOX) ** **** **** Burner Rack Complete (LP Gas) ** Burner Rack Only Gas Valve (Natural Gas) Gas Valve (LP Gas) Burner Tube (Standard) (Qty. 5) (Qty. 7) (Qty. 9) (Qty. 9) (Qty. 7) Burner Tube (Lo-NOX) (Qty. 5) (Qty. 7) **** **** (Qty. 7) Burner Tube (Stainless Steel) (Qty. 5) (Qty. 7) (Qty. 9) (Qty. 9) (Qty. 7) 33 Burner Manifold (Nat gas) Burner Manifold (LP gas) A Burner Manifold (Nat gas) Burner Manifold (LP gas) B Burner Manifold (Nat gas) Main Burner Orifice (Natural Gas) (0ft to 2000ft) (Qty. 5) (Qty. 7) (Qty. 9) (Qty. 9) (Qty. 7) High Altitude (Natural Gas) (2001ft to 5000ft) (Qty. 5) (Qty. 7) (Qty. 9) /8 (Qty. 9) (Qty. 7) High Altitude (Natural Gas) (5001ft to 8000ft) (Qty. 5) (Qty. 7) (Qty. 9) (Qty. 9) (Qty. 7) High Altitude (Natural Gas) (8001ft & above) (Qty. 5) (Qty. 7) (Qty. 9) (Qty. 9) (Qty. 7) Main Burner Orifice (LP Gas) (0ft to 2000ft) (Qty. 5) (Qty. 7) (Qty. 9) (Qty. 9) /16 (Qty. 7) High Altitude (LP Gas) (2001ft to 5000ft) (Qty. 5) (Qty. 7) (Qty. 9) (Qty. 9) (Qty. 7) High Altitude (LP Gas) (5001ft to 8000ft) (Qty. 5) /16 (Qty. 7) (Qty. 9) (Qty. 9) (Qty. 7) High Altitude (LP Gas) (8001ft & above) (Qty. 5) (Qty. 7) (Qty. 9) (Qty. 9) (Qty. 7) 35 Pilot Shield Pilot Assembly (Natural Gas) Pilot Assembly (LP Gas) Pilot Orifice (Natural Gas) Pilot Orifice (LP Gas) Aluminum Pilot Tube Burner Support Draft Panel Pilot Mounting Screw (Qty. 2) (Qty. 2) (Qty. 2) (Qty. 2) (Qty. 2) 42 Sreet Elbow 1" NPT (Nat.) Pipe Nipple 1" NPT (Nat.) Elbow 1" NPT (Nat.) Gas Support Bracket (Nat.) Gas Support Bracket (LP) Ground Wire LP to Natural Gas Conversion Kit * Applies to all warranties Applies when "E" is present in model ** Ordering a complete burner rack may increase number (Example: D38T155E3N). delivery time. Please order the specific 1 For serial numbers PRIOR to GB component required for the quickest delivery. 2 For serial numbers AFTER and including GB *** No LP version model available. 3 For serial numbers PRIOR to HA **** No Low Nox versions available over 400K btuh. 4 For serial numbers including and AFTER HA # A420 Anode may need to be cut to length Page 17

18 Page 18 Page 18

19 Item Description Model Model Model Model Model D80T199(E)*(N,X) D80T250(E)*(N,X)(A) D80T425*(N,X)(A) D80T505*(N,X)(A) D100L199(E)*(N,X) 21 Control Box Assembly (Dual Sensor) Control Box Assembly (Single Sensor) Control Box Cover Assembly Screw #8-18 X 3/4 Pan Head CR Honeywell Temperature Contol Display Control Box Cover Integrated Control Board (Dual Sensor) Integrated Control Board (Single Sensor) Screw #8-18 X 1/2 Pan Head CR Transformer 110V Ground Lug 1/4 x Power On/Off Switch Screw 8/32 X 1/4 Pan Head CR w/adh Primary Transformer Wiring Harness Secondary Transformer Wiring Harness Power Cord Wiring Harness Gas Valve Control Wiring Harness Damper Wiring Harness (Dual Sensor) Damper Wiring Harness (Single Sensor) Display Control Wiring Harness Display Cover Wiring Harness Control Box Panel Strain Relief Bushing 7/8" Snap-in Bushing 7/8" Strain Relief Bushing 1/2" * Applies to all warranties Applies when "E" is present in model ** Ordering a complete burner rack may increase number (Example: D38T155E3N). delivery time. Please order the specific 1 For serial numbers PRIOR to GB component required for the quickest delivery. 2 For serial numbers AFTER and including GB *** No LP version model available. 3 For serial numbers PRIOR to HA **** No Low Nox versions available over 400K btuh. 4 For serial numbers including and AFTER HA # A420 Anode may need to be cut to length Page 19

20 Page 20 Page 20

21 Item Description Model Model Model Model Model D100L250(E)*(N,X)(A) D100L270(E)*N(A) D100L300(E)*(N,X)(A) D100S199(E)*(N,X) D100S250(E)*(N,X)(A) 1 Draft Diverter Complete with Leg Kit Draft Diverter Only Draft Diverter Leg Kit Only Flue Damper Reducer Flue Damper Complete Hot Water Outlet Nipple (Top) Cold Water Inlet Diptube (Top) Plug Type Anode Rod (Magnesium) (Qty. 4) (Qty. 4) (Qty. 4) (Qty. 4) (Qty. 4) Plug Type Anode Rod (Aluminum) (Qty. 4) (Qty. 4) (Qty. 4) (Qty. 4) (Qty. 4) Plug Type Anode Rod (A420 Aluminum)# (Qty. 4) (Qty. 4) (Qty. 4) (Qty. 4) (Qty. 4) 9 Flue Baffle (Qty. 12) (Qty. 12) (Qty. 12) (Qty. 9) (Qty. 9) 10 Flue Core A Flue Reducer ASSE Approved Mixing Valve (Optional) Upper Thermostat Sensor Hot Water Outlet Nipple (Side) " NPT to 3/4" NPT Reducer Bushing /4" NPT Nipple " NPT Nipple T&P Valve Utility Cover Lower Thermostat Well Clip for Lower Thermostat Lower Thermostat Sensor Control Box Assembly SEE PAGE 25 SEE PAGE 25 SEE PAGE 25 SEE PAGE 25 SEE PAGE Cold Water Inlet Diptube (Side) Brass Drain Valve Cleanout O-Ring Gasket A Cleanout Gasket (ASME) Cleanout Cover A Cleanout Cover (ASME) Cleanout Cover Screw (Qty. 6) (Qty. 6) (Qty. 6) (Qty. 6) (Qty. 6) 26A Cleanout Cover Screw (ASME) (Qty. 6) (Qty. 6) (Qty. 6) (Qty. 6) 27 Cleanout Access Cover Pipe plug (3/4 NPT) * Applies to all warranties Applies when "E" is present in model ** Ordering a complete burner rack may increase number (Example: D38T155E3N). delivery time. Please order the specific 1 For serial numbers PRIOR to GB component required for the quickest delivery. 2 For serial numbers AFTER and including GB *** No LP version model available. 3 For serial numbers PRIOR to HA **** No Low Nox versions available over 400K btuh. 4 For serial numbers including and AFTER HA # A420 Anode may need to be cut to length Page 21

22 Page 22 Page 22

23 Item Description Model Model Model Model Model D100L250(E)*(N,X)(A) D100L270(E)*N(A) D100L300(E)*(N,X)(A) D100S199(E)*(N,X) D100S250(E)*(N,X)(A) 29 Burner Rack Complete (Natural Gas) ** Burner Rack Complete (Nat. Gas)(Lo NOX) ** Burner Rack Complete (LP Gas) ** Burner Rack Only Gas Valve (Natural Gas) Gas Valve (LP Gas) Burner Tube (Standard) (Qty. 7) (Qty. 7) (Qty. 7) (Qty. 5) (Qty. 5) Burner Tube (Lo-NOX) (Qty. 7) (Qty. 7) (Qty. 7) (Qty. 5) (Qty. 5) Burner Tube (Stainless Steel) (Qty. 7) (Qty. 7) (Qty. 7) (Qty. 5) (Qty. 5) 33 Burner Manifold (Nat gas) Burner Manifold (LP gas) A Burner Manifold (Nat gas) Burner Manifold (LP gas) B Burner Manifold (Nat gas) Main Burner Orifice (Natural Gas) (0ft to 2000ft) (Qty. 7) (Qty. 7) (Qty. 7) (Qty. 5) (Qty. 5) High Altitude (Natural Gas) (2001ft to 5000ft) (Qty. 7) (Qty. 7) (Qty. 7) (Qty. 5) (Qty. 5) High Altitude (Natural Gas) (5001ft to 8000ft) (Qty. 7) (Qty. 7) (Qty. 7) (Qty. 5) (Qty. 5) High Altitude (Natural Gas) (8001ft & above) (Qty. 7) (Qty. 7) (Qty. 7) (Qty. 5) (Qty. 5) Main Burner Orifice (LP Gas) (0ft to 2000ft) (Qty. 7) *** (Qty. 7) (Qty. 5) (Qty. 5) High Altitude (LP Gas) (2001ft to 5000ft) (Qty. 7) *** (Qty. 7) (Qty. 5) (Qty. 5) High Altitude (LP Gas) (5001ft to 8000ft) /16 (Qty. 7) *** (Qty. 7) (Qty. 5) (Qty. 5) High Altitude (LP Gas) (8001ft & above) (Qty. 7) *** (Qty. 7) (Qty. 5) (Qty. 5) 35 Pilot Shield Pilot Assembly (Natural Gas) Pilot Assembly (LP Gas) *** Pilot Orifice (Natural Gas) Pilot Orifice (LP Gas) *** Aluminum Pilot Tube Burner Support Draft Panel Pilot Mounting Screw (Qty. 2) (Qty. 2) (Qty. 2) (Qty. 2) (Qty. 2) 42 Sreet Elbow 1" NPT (Nat.) Pipe Nipple 1" NPT (Nat.) Elbow 1" NPT (Nat.) Gas Support Bracket (Nat.) Gas Support Bracket (LP) Ground Wire LP to Natural Gas Conversion Kit * Applies to all warranties Applies when "E" is present in model ** Ordering a complete burner rack may increase number (Example: D38T155E3N). delivery time. Please order the specific 1 For serial numbers PRIOR to GB component required for the quickest delivery. 2 For serial numbers AFTER and including GB *** No LP version model available. 3 For serial numbers PRIOR to HA **** No Low Nox versions available over 400K btuh. 4 For serial numbers including and AFTER HA # A420 Anode may need to be cut to length Page 23

24 Page 24 Page 24

25 Item Description Model Model Model Model Model D100L250(E)*(N,X)(A) D100L270(E)*N(A) D100L300(E)*(N,X)(A) D100S199(E)*(N,X) D100S250(E)*(N,X)(A) 21 Control Box Assembly (Dual Sensor) Control Box Assembly (Single Sensor) Control Box Cover Assembly Screw #8-18 X 3/4 Pan Head CR Honeywell Temperature Contol Display Control Box Cover Integrated Control Board (Dual Sensor) Integrated Control Board (Single Sensor) Screw #8-18 X 1/2 Pan Head CR Transformer 110V Ground Lug 1/4 x Power On/Off Switch Screw 8/32 X 1/4 Pan Head CR w/adh Primary Transformer Wiring Harness Secondary Transformer Wiring Harness Power Cord Wiring Harness Gas Valve Control Wiring Harness Damper Wiring Harness (Dual Sensor) Damper Wiring Harness (Single Sensor) Display Control Wiring Harness Display Cover Wiring Harness Control Box Panel Strain Relief Bushing 7/8" Snap-in Bushing 7/8" Strain Relief Bushing 1/2" * Applies to all warranties Applies when "E" is present in model ** Ordering a complete burner rack may increase number (Example: D38T155E3N). delivery time. Please order the specific 1 For serial numbers PRIOR to GB component required for the quickest delivery. 2 For serial numbers AFTER and including GB *** No LP version model available. 3 For serial numbers PRIOR to HA **** No Low Nox versions available over 400K btuh. 4 For serial numbers including and AFTER HA # A420 Anode may need to be cut to length Page 25

26 Page 26 Page 26

27 Item Description Model Model D100T199(E)*(N,X) D100T250(E)*(N,X)(A) 1 Draft Diverter Complete with Leg Kit Draft Diverter Only Draft Diverter Leg Kit Only Flue Damper Reducer Flue Damper Complete Hot Water Outlet Nipple (Top) Cold Water Inlet Diptube (Top) Plug Type Anode Rod (Magnesium) (Qty. 2) (Qty. 2) Plug Type Anode Rod (Aluminum) (Qty. 2) (Qty. 2) Plug Type Anode Rod (A420 Aluminum)# (Qty. 2) (Qty. 2) 9 Flue Baffle (Qty. 8) (Qty. 8) 10 Flue Core A Flue Reducer ASSE Approved Mixing Valve (Optional) Upper Thermostat Sensor Hot Water Outlet Nipple (Side) " NPT to 3/4" NPT Reducer Bushing /4" NPT Nipple " NPT Nipple T&P Valve Utility Cover Lower Thermostat Well Clip for Lower Thermostat Lower Thermostat Sensor Control Box Assembly SEE PAGE 31 SEE PAGE Cold Water Inlet Diptube (Side) Brass Drain Valve Cleanout O-Ring Gasket A Cleanout Gasket (ASME) Cleanout Cover A Cleanout Cover (ASME) Cleanout Cover Screw (Qty. 6) (Qty. 6) 26A Cleanout Cover Screw (ASME) (Qty. 6) 27 Cleanout Access Cover Pipe plug (3/4 NPT) * Applies to all warranties Applies when "E" is present in model ** Ordering a complete burner rack may increase number (Example: D38T155E3N). delivery time. Please order the specific 1 For serial numbers PRIOR to GB component required for the quickest delivery. 2 For serial numbers AFTER and including GB *** No LP version model available. 3 For serial numbers PRIOR to HA **** No Low Nox versions available over 400K btuh. 4 For serial numbers including and AFTER HA # A420 Anode may need to be cut to length Page 27

28 Page 28 Page 28

29 Item Description Model Model D100T199(E)*(N,X) D100T250(E)*(N,X)(A) 29 Burner Rack Complete (Natural Gas) ** Burner Rack Complete (Nat. Gas)(Lo NOX) ** Burner Rack Complete (LP Gas) ** Burner Rack Only Gas Valve (Natural Gas) Gas Valve (LP Gas) Burner Tube (Standard) (Qty. 5) (Qty. 5) Burner Tube (Lo-NOX) (Qty. 5) (Qty. 5) Burner Tube (Stainless Steel) (Qty. 5) (Qty. 5) 33 Burner Manifold (Nat gas) Burner Manifold (LP gas) A Burner Manifold (Nat gas) Burner Manifold (LP gas) B Burner Manifold (Nat gas) Main Burner Orifice (Natural Gas) (0ft to 2000ft) (Qty. 5) (Qty. 5) High Altitude (Natural Gas) (2001ft to 5000ft) (Qty. 5) (Qty. 5) High Altitude (Natural Gas) (5001ft to 8000ft) (Qty. 5) (Qty. 5) High Altitude (Natural Gas) (8001ft & above) (Qty. 5) (Qty. 5) Main Burner Orifice (LP Gas) (0ft to 2000ft) (Qty. 5) (Qty. 5) High Altitude (LP Gas) (2001ft to 5000ft) (Qty. 5) (Qty. 5) High Altitude (LP Gas) (5001ft to 8000ft) (Qty. 5) (Qty. 5) High Altitude (LP Gas) (8001ft & above) (Qty. 5) (Qty. 5) 35 Pilot Shield Pilot Assembly (Natural Gas) Pilot Assembly (LP Gas) Pilot Orifice (Natural Gas) Pilot Orifice (LP Gas) Aluminum Pilot Tube Burner Support Draft Panel Pilot Mounting Screw (Qty. 2) (Qty. 2) 42 Sreet Elbow 1" NPT (Nat.) Pipe Nipple 1" NPT (Nat.) Elbow 1" NPT (Nat.) Gas Support Bracket (Nat.) Gas Support Bracket (LP) Ground Wire LP to Natural Gas Conversion Kit * Applies to all warranties Applies when "E" is present in model ** Ordering a complete burner rack may increase number (Example: D38T155E3N). delivery time. Please order the specific 1 For serial numbers PRIOR to GB component required for the quickest delivery. 2 For serial numbers AFTER and including GB *** No LP version model available. 3 For serial numbers PRIOR to HA **** No Low Nox versions available over 400K btuh. 4 For serial numbers including and AFTER HA # A420 Anode may need to be cut to length Page 29

Rheem Spare Parts Manual. Commercial gas model A631265 Exterior 265L

Rheem Spare Parts Manual. Commercial gas model A631265 Exterior 265L Commercial gas model A631265 Exterior 265L Commercial gas model A631265 Exterior 265L Item Part No. Description 1 221735 Foam cover 2 221914 Anode x 3 (black) 1153mm 2 221924 Anode x 3 (blue) 1153mm 3

More information

Energy Saver SERVICE MANUAL COMMERCIAL 24 VOLT FLUE DAMPER SERIES WATER HEATER ATMOSPHERIC GAS WATER HEATERS

Energy Saver SERVICE MANUAL COMMERCIAL 24 VOLT FLUE DAMPER SERIES WATER HEATER ATMOSPHERIC GAS WATER HEATERS Energy Saver COMMERCIAL 24 VOLT FLUE DAMPER SERIES WATER HEATER ATMOSPHERIC GAS WATER HEATERS SERVICE MAUAL Troubleshooting Guide and Instructions for Service (To be performed OL by qualified service providers)

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

RAYPAK HEATERS. Gas Heaters H-90 GUIDE TO MOST COMMON PARTS E-Z FIND

RAYPAK HEATERS. Gas Heaters H-90 GUIDE TO MOST COMMON PARTS E-Z FIND RAYPAK HEATERS Heaters H-90 GUIDE TO MOST COMMON PARTS E-Z FIND FRONT HEADER RETURN HEADER HEADER GASKET FLANGE CHART FLANGE GASKET THERMOSTAT* HI LIMIT SWITCH PRESSURE SWITCH GAS VALVE MV NATURAL GAS

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R8202395-02EN - Edition 02-21/04/2005

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R8202395-02EN - Edition 02-21/04/2005 CUENOD Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CELTIC RSc b R8202395-02EN - Edition 02-21/04/2005 Boilers Solar Panel 69214511 31 CELTIC

More information

ZEPHAIRE G, ZEPHAIRE G PLUS & ZEPHAIRE-200-G GAS CONVECTION OVENS REPLACEMENT PARTS LIST

ZEPHAIRE G, ZEPHAIRE G PLUS & ZEPHAIRE-200-G GAS CONVECTION OVENS REPLACEMENT PARTS LIST ZEPHAIRE G, ZEPHAIRE G PLUS & ZEPHAIRE-200-G GAS CONVECTION OVENS REPLACEMENT PARTS LIST EFFECTIVE JULY 29, 2016 Superseding All Previous s Lists. The Company reserves the right to make substitution in

More information

Vectaire Gas Convection Ovens (Vertical Door)

Vectaire Gas Convection Ovens (Vertical Door) MONTAGUE Vectaire Gas Convection Ovens (Vertical Door) 70, 115 2-70 & 2-115 Vectaire Gas Convection Ovens (Vertical Door) 456 115A Series Vertical Door Model 1 3395-2 Thermostat, Gas (FDO) 2 1024-3 Dial,

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009 Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters POWERED BURNER MODELS LARGE-VOLUME POWERED BURNER FEATURES The large-volume powered burner line includes the largest, most powerful A. O. Smith tanktype gas water heaters. With tank capacities up to 600

More information

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

TANKLESS WATER HEATER INSTALLATION DIAGRAMS TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water

More information

Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.

Double-Headed Screw 1. 3/4 FIP x 3/4 MIP x 1/4 hole 2. 3/4 Fip x 3/4 MIP. Feed Water Connector 1. 1/2 FIP x 1/2 MIP x 1/4 OD 2. 3. Picture Item No. Description RO- 0010 Brass Water Feed 1. 3/4" FIP with 1/4" hole 2. Using on R.O. tank RO- O020 Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP RO- 0030 Brass

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

NAVIEN AMERICA INC. 17855 FITCH AVENUE

NAVIEN AMERICA INC. 17855 FITCH AVENUE Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:

More information

MODEL TF, RF & SF GAS-FIRED TUBULAR UNIT HEATERS

MODEL TF, RF & SF GAS-FIRED TUBULAR UNIT HEATERS CATALOG NO.: TFPC-8 SUPERCEDES: TFPC-4 MODEL TF, RF & SF GAS-FIRED TUBULAR UNIT HEATERS REPLACEMENT PARTS CATALOG INDEX WARRANTY INFORMATION RETURN GOODS...2 CONVERSION KITS...3 SF-30/75 SEPARATED COMBUSTION

More information

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY Form CP-F/B-GC (Version A.2) Obsoletes Form CP-F/B-GC (Version A) Gas Conversion Kits and Instructions Applies to: Models F, B, FE, and BE Model B Model F All gas conversion must be done by a qualified

More information

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty One Year Warranty ELECTRIC Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches Fused Ceramic Shield tank lining is corrosion-resistant for years of dependability. Adjustable

More information

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

80-115 80-140 80-180 95-199 95-260 70-360 65-400 65-500

80-115 80-140 80-180 95-199 95-260 70-360 65-400 65-500 Release R.2.0 Uk 80-115 80-140 80-180 95-199 95-260 70-360 65-400 65-500 Installation User and Service Manual www.state-waterheaters.co.uk your installer Warning Read this manual carefully before first

More information

High efficiency, cast-iron gas boiler

High efficiency, cast-iron gas boiler SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home

More information

Pilot Water Heater 6-10 Gallon

Pilot Water Heater 6-10 Gallon Pilot Water Heater 6-10 Gallon First number in matrix refers to illustration number, the second is the part number. 20 1 10 19 21 17 13 18 16 13 14 15 7 6 5 3 12 10 10 9 8 4 11 2 26 28 29 22 23 27 25 23

More information

PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS

PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS AC AND DC GENERATOR SCHEMATIC ENGINE GENERATOR ASSEMBLY REF Description QTY PSS10 PSS12 1 Engine, Honda GX620K1VXC2 Code 637220 1 99779-000 GX670VXC2 Code 637220

More information

PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM

PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM RELIANCE Has Everything Your Customers Need to Do the Job Right! Reliance Water Heater Company was founded in 1981 to provide a water heater

More information

COMMERCIAL GAS DRYER

COMMERCIAL GAS DRYER COMMERCIAL GAS DRYER MODELS CGD8990XW0 4 12 Litho In U.S.A. (CMS) (psw) c 2012 WHIRLPOOL CORPORATION Part No. Rev. B TOP AND CONSOLE PARTS 2 TOP AND CONSOLE PARTS 1 Literature Parts W10184516 Installation

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...

More information

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION

More information

ALTRA 400 Operator Manual. Planographs and Wiring Diagrams

ALTRA 400 Operator Manual. Planographs and Wiring Diagrams Planographs and Wiring Diagrams 16 Altra 400 Final Assembly All Altras w/head # Part # Description Specific Use (if any) 1 60323A Tank Assy, Altra 400 115 Volt model 60358A Tank Assy, Altra 400 SP 230

More information

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S *1756202470* 17562.0247.0 REV3 06/09 2012 Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S Issue Table description Issue n. of pages Overall view 06/2009 1 C.h.

More information

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless) OVEN PARTS 30" BUILT IN ELECTRIC COMBO SENSOR/SC (GOLD LINE) 3 05 Litho In U.S.A. (cre) 1 Part No. Rev.A OVEN PARTS 1 Literature Parts 4455994 Installation Instructions Use & Care Guide 8300346 Microwave

More information

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number: Seaward Products WATER HEATERS OWNER S MANUAL Serial Number: IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, basic safety precautions to reduce the risk of fire, electrical shock,

More information

Spare Parts List M96A.24SM/B M96A.28SM/B

Spare Parts List M96A.24SM/B M96A.28SM/B *16202390* 162.0239.0 REV5 14/04 2015 Spare Parts List M96A.24SM/B M96A.28SM/B Issue Table description Issue n. of pages Overall view 09/2008 1 C.h. return group and d.h.w. heat exchanger 09/2008 1 C.h.

More information

UNIVERSAL 1550 PRE-MIX DISPENSER

UNIVERSAL 1550 PRE-MIX DISPENSER MODEL NO. 284974xxx 1 of 8 Control Code A ªIMI Cornelius Co., 1987-95 22 5 6 2 3 7 4 1 26 32 19 28 33 29 27 11 15 18 16 17 14 9 31 30 34 24 20 23 8 10 21 13 FIGURE 1. ASSEMBLY ªIMI Cornelius Co., 1987-95

More information

Spare Parts List Activ A 12OV Activ A 15OV Activ A 20OV Activ A 25OV

Spare Parts List Activ A 12OV Activ A 15OV Activ A 20OV Activ A 25OV *175620240* 17562.024.0 REV1 01/06 2010 Spare Parts List Activ A 12OV Issue Table description Issue n. of pages Overall view 1 Main circuit assembly 1 Gas assembly 1 Valves and connection pipes 1 Control

More information

OVEN PARTS For Models:GMC305PDB07, GMC305PDQ07, GMC305PDT07, GMC305PDS07 (Black) (White) (Biscuit) (S.Steel)

OVEN PARTS For Models:GMC305PDB07, GMC305PDQ07, GMC305PDT07, GMC305PDS07 (Black) (White) (Biscuit) (S.Steel) OVEN PARTS 30" BUILT IN ELECTRIC COMBO SENSOR/SC (GOLD LINE) 7 03 Litho In U.S.A. (cre) 1 Part No. OVEN PARTS NOTE: The screws and nuts required to attach a part are listed immediately following that part.

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable

More information

The Bradford White. Save this manual for future reference. (To be performed ONLY by qualified service providers)

The Bradford White. Save this manual for future reference. (To be performed ONLY by qualified service providers) The Bradford White R (To be performed ONLY by qualified service providers) R U130T*FRN U130S*FRN U140T*FRN U1403T*FRN U1403S*FRN U1404T*FRN U1503*FRN U150L*FRN U1504S*FRN U430T*FRN U440T*FRN U4403S*FRN

More information

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit IMPORTANT: These installation instructions are meant to be used as a guide for woodstove owners and

More information

ILLUSTRATED PARTS LIST XTREME ICE MAKER (1230 SERIES) MODEL NO.

ILLUSTRATED PARTS LIST XTREME ICE MAKER (1230 SERIES) MODEL NO. XTREME ICE MAKER (0 SERIES) MODEL NO. 00 00 00 00 00 00 0 XTREME ICE MAKER (0 SERIES) FIGURE. GENERAL ASSEMBLY (AIR CONDENSER SHOWN) 00 Screw TC - HXWS 00000 Screw TC - HXWS 0 (Marine) 0000 Grommet Nut

More information

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating

More information

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND Honeywell Electronic Ignition Troubleshooting Tech Tip April 2007 The Honeywell S8610H Intermittent Pilot Module provides the ignition sequencing, pilot spark, pilot flame monitoring, Pilot Valve (PV)

More information

REPLACEMENT PARTS LIST PRICE BOOK Effective with Shipments October 1, 2010 #NSBPB00209 (Revised for October 2010)

REPLACEMENT PARTS LIST PRICE BOOK Effective with Shipments October 1, 2010 #NSBPB00209 (Revised for October 2010) REPLACEMENT PARTS LIST PRICE BOOK Effective with Shipments October 1, 2010 #NSBPB00209 (Revised for October 2010) www.americanwaterheater.com Ordering Terms and Conditions Parts listed represent the most

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

REDFYRE CENTRAL-HEATING COOKER (OIL & GAS FIRED)

REDFYRE CENTRAL-HEATING COOKER (OIL & GAS FIRED) REDFYRE CENTRAL-HEATING COOKER (OIL & GAS FIRED) MODELS 0, 80, 00, 20 PARTS LIST AUGUST 202 A REDFYRE CENTRAL HEATING COOKER ---- TOP - PLATE & LIDS 2 REDFYRE CENTRAL HEATING COOKER ---- TOP - PLATE &

More information

FLASH TANK ECONOMIZER PRODUCT GUIDE

FLASH TANK ECONOMIZER PRODUCT GUIDE FLASH TANK ECONOMIZER PRODUCT GUIDE Overview A flash tank is used to recover blowdown energy in the form of flash steam and blowdown. This can only be used with a deaerator or some other pressurized device.

More information

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI). SECTION 23 52 30 PART 1 - GENERAL 1.01 RELATED WORK A. Section 23 05 00: Common Work Results for HVAC B. Section 23 25 00: Chemical Water Treatment C. Section 23 51 23: Flue Piping 1.02 QUALITY ASSURANCE

More information

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled

More information

MODEL BRT GAS-FIRED TUBULAR UNIT HEATERS

MODEL BRT GAS-FIRED TUBULAR UNIT HEATERS CATALOG NO.: BRTPC-3 GAS-FIRED UNIT HEATERS MODEL BRT GAS-FIRED TUBULAR UNIT HEATERS CATALOG INDEX WARRANTY INFORMATION RETURN GOODS...2 BRT-30/120...3, 4, 5 OPTIONAL PARTS...6 CONVERSION KITS...7 TERMS...8

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT ALPKT7- INSTALLATION INSTRUCTIONS PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements... INSTALLATION INSTRUCTIONS...

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

TB-A028-06 - A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

TB-A028-06 - A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION 1 2 3 4 5 Inadequate or no earth ground sensed by the Intelli-Vent control. Power supply to Intelli-Vent control has reversed polarity. Pressure switch circuit remaining closed for more than 5 seconds

More information

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................

More information

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage

More information

AD-75V/AD-758V. Parts Manual

AD-75V/AD-758V. Parts Manual AD-75V/AD-758V Dual Timer Phase 7 OPL with S.A.F.E. Options Parts Manual American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com

More information

Product and Safety Information... 2,3 Service and Maintenance Munchkin Operation Primary Water

Product and Safety Information... 2,3 Service and Maintenance Munchkin Operation Primary Water User Manual TABLE OF CONTENTS Product and Safety Information............................................. 2,3 Service and Maintenance Munchkin Operation Primary Water Section I Combustion Air Prevention

More information

COMMERCIAL GAS DRYER

COMMERCIAL GAS DRYER COMMERCIAL GAS DRYER MODELS CGM2751TQ0 (WHITE) CGM2751TQ1 (WHITE) 5 12 Litho in U.S.A. (CMS) (psw) c 2012 WHIRLPOOL CORPORATION Part No. W10119631 Rev. C TOP AND CONSOLE PARTS W10119631 2 TOP AND CONSOLE

More information

CutMaster 102. 6.04 Major External Replacement Parts

CutMaster 102. 6.04 Major External Replacement Parts CutMaster 0 6.04 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-086 Tube, roll handle 9-0 4 Front Panel 9-087 Rear Panel 9-00 4 Art #

More information

LYCOMING O-360. Engine Installation

LYCOMING O-360. Engine Installation Engine Installation SECTION 3 Fuel Lines FUEL FITTINGS ON THE CARBURETOR AND MECHANICAL FUEL PUMP, ALSO THE FUEL LINES TO AND FROM THE MECHANICAL FUEL PUMP ELECTRIC FUEL PUMP ASSEMBLY: TOP THE FUEL PUMP

More information

http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html

http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html TECHNICAL SERVICE DEPARTMENT Removal, Cleaning, & Reinstallation of the Burner Assembly For models 74 & GT199 Required tools -

More information

SPIDERfire: Delivers high efficiency and real savings for today s businesses

SPIDERfire: Delivers high efficiency and real savings for today s businesses Product Brochure Commercial Water Heaters SPIDERfire Series SPIDERfire: Delivers high efficiency and real savings for today s businesses Up to 97% thermal efficiency 80 and 100-gallon capacity models Patented

More information

OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608

OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 36C01 Combination Gas Valves (24 Volt and 120 Volt Models) INSTALLATI INSTRUCTIS FAILURE TO READ AND FOLLOW ALL INSTRUCTIS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CTROL COULD CAUSE

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters UP TO 96% THERMAL EFFICIENCY, DIRECT-VENT FEATURES TM BTH-120 through BTH-500 The A. O. Smith Cyclone Xi family of products represents the industry s most technologically advanced commercial water heaters.

More information

CutMaster 82. 6.04 Major External Replacement Parts

CutMaster 82. 6.04 Major External Replacement Parts CutMaster 8 6.0 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-08 Tube, roll handle 9-0 Front Panel 9-07 Rear Panel 9-00 Art # A-080

More information

Parts. Ultra 395/495/595t Ultra Max II 490/495/595t 309675V 120 VAC. 3300 psi (228 bar, 22.8 MPa) Maximum Working Pressure.

Parts. Ultra 395/495/595t Ultra Max II 490/495/595t 309675V 120 VAC. 3300 psi (228 bar, 22.8 MPa) Maximum Working Pressure. Parts Ultra 395/495/595t Ultra Max II 490/495/595t 309675V EN 3300 psi (228 bar, 22.8 MPa) Maximum Working Pressure 0 VAC Type Stand Series Lo-boy Series Hi-boy Series Ultra 395t 2339 B 233961 B 233962

More information

PARTS NEEDED FOR CONVERTING FROM LP TO NG

PARTS NEEDED FOR CONVERTING FROM LP TO NG 1 6 7 8 3 5 4 10 9 2 PARTS NEEDED FOR CONVERTING FROM LP TO NG Number Description 1 30" NG Manifold 2 NG side burner valve 3 NG Regulator 4 Rear I/R NG orifice 4 Rear I/R NG orifice 5 Side burner NG orifice

More information

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N 265-47200-00

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N 265-47200-00 Instructions for: TTW 1 Universal Service Kit P/N 265-47200-00 (To be performed ONLY by qualified service providers) The Blowers on the Following Water Heaters are Serviced by This Kit: MITW -10 Series

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

MODELS BTR(C)120 THRU 500A

MODELS BTR(C)120 THRU 500A MODELS BTR(C)120 THRU 500A COMMERCIAL GAS, GLASS-LINED, TANK-TYPE WATER HEATER INSTALLATION OPERATION MAINTENANCE LIMITED WARRANTY Thank you for buying this energy efficient water heater from A.O. Smith

More information

!"" #$% "!&' ( ( ) *

! #$% !&' ( ( ) * !"" #$% "!&' (( ) * G Whiz Gas Popper Instruction Manual Model #5908 Part No. 74874 Revised October 1997 Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells

More information

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves 2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating

More information

COOLING SYSTEM Section Page

COOLING SYSTEM Section Page 5 COOLING SYSTEM Section Page 5.1 COOLANT PRE-HEATER... 5-3 5.2 COOLANT PUMP NON-EGR ENGINE... 5-7 5.3 COOLANT PUMP EGR ENGINE... 5-13 5.4 FRONT CONNECTOR HOUSING NON-EGR ENGINE... 5-17 5.5 FRONT CONNECTOR

More information

PARTS LIST T30 MODEL 2545 TWO STAGE INDUSTRIAL AIR COMPRESSOR

PARTS LIST T30 MODEL 2545 TWO STAGE INDUSTRIAL AIR COMPRESSOR Ingersoll-Rand Company 800-B Beaty Street P. O. Box 1803 Davidson, NC 28036 1-800-AIR-SERV (1-800-247-7378) www.air.ingersoll-rand.com PARTS LIST T30 MODEL 2545 TWO STAGE INDUSTRIAL AIR COMPRESSOR Ingersoll-Rand

More information

GROENEVELD AUTOMATIC GREASING SYSTEMS

GROENEVELD AUTOMATIC GREASING SYSTEMS GROENEVELD AUTOMATIC GREASING SYSTEMS TWIN Parts & Accessories Book Pumps, Fittings, Injectors, Lining, etc. www.groeneveld-group.com 1 TWIN ELECTRICAL Item Part # Description 1 F113966 Switch 24V 2 F122991

More information

LPM-06 CONVERSION KIT

LPM-06 CONVERSION KIT LPM-06 CONVERSION KIT TWO-STAGE FURNACE NATURAL GAS TO L.P. GAS CONVERSION Goodman Manufacturing Company, L.P. 2009-2011 5151 San Felipe, Suite 500, Houston, TX 77056 www.goodmanmfg.com -or- www.amana-hac.com

More information

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

INDIRECT WATER HEATER. Installation and Operating Instruction Manual INDIRECT WATER HEATER Installation and Operating Instruction Manual Maximum supply temperature to heat exchanger must not exceed 180 F (82 C). Safety Warning: Indirect water heaters are heat-producing

More information

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler Advanced Heating & Hot Water Systems A Trailblazing Energy Star Listed Boiler that Installs like a Mid-Efficiency Boiler with the Performance of a High-Efficiency Product Ultra High Efficiency Energy Star

More information

G234X-55 Conventional Gas Boiler

G234X-55 Conventional Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural

More information

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers Peerless Boilers Series GM Residential/Commercial Gas Boilers The Series GM cast iron, hot water boiler is ideal for use in large residences or commercial applications. This gas-fired, atmospheric boiler

More information

INSTALLATION INSTRUCTIONS BL-8704

INSTALLATION INSTRUCTIONS BL-8704 INSTALLATION INSTRUCTIONS BL-8704 EXPOSED BLACK LEVER THERMOSTATIC MIXING VALVE WITH RISER KIT, HANDSET, LEVER DIVERTER, 8 ROSE AND ADJUSTABLE RISER PIPE BRACKET. Dimensions in Inches (& Millimetres) 1

More information

RICAMBI FLECK WATERBOOK 2006-2007 - LISTINO GENERALE

RICAMBI FLECK WATERBOOK 2006-2007 - LISTINO GENERALE RICAMBI FLECK P/N 0 O'ring 560 CD 0 P/N 050 Grommet pass rod 20 2300/230/ 2350 P/N 060 Tube 3/8in (0,92 m) 0 P/N 086 Holding Nut M5 2300 0 P/N 0209-0 Quad Ring 560 CD 0 P/N 028 Microswitch 5 P/N 0220 Screw

More information

Service Parts. John Deere TO4039D 4039TL CD4039DF CD4039TF 4045DF 4045TF. Engine. Engine Models:

Service Parts. John Deere TO4039D 4039TL CD4039DF CD4039TF 4045DF 4045TF. Engine. Engine Models: Service s Engine Engine Models: John Deere TO4039D 4039TL CD4039DF CD4039TF 4045DF 4045TF Generator Models: 20--40ROZJ/REOZJ 20--40DSJ/DSEJ 50/60ROZJ serial nos. 257821 and above 50/60REOZJ/REOZJB 50/60DSJ/DSEJ/DSEJB

More information

OVEN PARTS For Models:RBS305PDB16, RBS305PDQ16, RBS305PDT16, RBS305PDS16 (Black) (Designer White) (Biscuit) (S.Steel)

OVEN PARTS For Models:RBS305PDB16, RBS305PDQ16, RBS305PDT16, RBS305PDS16 (Black) (Designer White) (Biscuit) (S.Steel) OVEN PARTS 30" BUILT IN ELECTRIC OVEN SELF CLEAN 10 04 Litho in U.S.A.(cre) 1 Part No. OVEN PARTS 1 Literature Parts LIT8300654 Installation Instructions LIT8300772 Use & Care Guide (Oven) LIT8301758 Tech

More information

TOP AND CABINET PARTS

TOP AND CABINET PARTS TOP AND CABINET PARTS AUTOMATIC WASHER 9 06 Printed in U.S.A. (drd) 1 Part No. Rev. A TOP AND CABINET PARTS 1 Literature Parts 8182271 Use & Care Guide 8182277 Tech Sheet 8182614 Energy Guide 8182196 Quick

More information

Stainless Steel Single and Dual Circulation Kits

Stainless Steel Single and Dual Circulation Kits Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating

More information

AFE424 SERVICE PARTS

AFE424 SERVICE PARTS This is the parts list for the AFE. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The Air Cooled model has also been manufactured

More information

Filters Air Dryers 08

Filters Air Dryers 08 Filters Air Dryers 08 PuraGuard Filter For service new replacement assembly use PuraGuard QC Filter Service 801731 Maintenance Kit 5006788 Rebuild Kit 5006789 Included In Kit 5006788 Included In Kit 5006789

More information

Electric Mini Tank Water heaters GL 2.5 - GL 4 - GL 6+

Electric Mini Tank Water heaters GL 2.5 - GL 4 - GL 6+ Electric Mini Tank Water heaters GL 2.5 - GL 4 - GL 6+ IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, safety precautions to reduce the risk of fire, electric shock or injury to

More information

INSTALLATION INSTRUCTIONS MK-8704

INSTALLATION INSTRUCTIONS MK-8704 INSTALLATION INSTRUCTIONS MK-8704 EXPOSED MACKINTOSH THERMOSTATIC MIXING VALVE WITH RISER KIT, HANDSET, LEVER DIVERTER, 8 ROSE AND ADJUSTABLE RISER PIPE BRACKET. Dimensions in Inches (& Millimetres) 1

More information

2007 GFEN Blue Flame Product of the Year Award Form

2007 GFEN Blue Flame Product of the Year Award Form 2007 GFEN Blue Flame Product of the Year Award Form Please e-mail this form to GFEN with supporting documentation: photo(s), specification sheets, brochures, etc. to GFEN. Entries must be submitted no

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining

More information

SCCG50 & SCCP50 Service Parts

SCCG50 & SCCP50 Service Parts SCCG0 & SCCP0 Service Parts This is the illustrated parts list for the SCCG0M and the SCCP0M esidential Ice Machines hen ordering a service part, always refer to the complete model number of the equipment

More information

Repair Parts List REFRIGERATOR MODEL NUMBER MFI2067AES. When requesting service or ordering parts, always provide the following information:

Repair Parts List REFRIGERATOR MODEL NUMBER MFI2067AES. When requesting service or ordering parts, always provide the following information: Repair Parts List REFRIGERATOR MODEL NUMBER MFI2067AES When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description

More information

Repair Parts List DRYER MODEL NUMBER MDE3000AYW. When requesting service or ordering parts, always provide the following information:

Repair Parts List DRYER MODEL NUMBER MDE3000AYW. When requesting service or ordering parts, always provide the following information: Repair Parts List DRYER MODEL NUMBER MDE3000AYW When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description 2005

More information

TANKLESS DURABILITY Tankless Product Guide

TANKLESS DURABILITY Tankless Product Guide TANKLESS DURABILITY Tankless Product Guide Energy-efficient, plentiful, and endless supply of hot water. Compact size and wall-mounted to free up valuable floor space. SAVE ENERGY. SAVE SPACE. PAGE [ 2

More information

WH/WIH/WIHD/WIHD&M/WIHL AND WIH 17-67 SERIES

WH/WIH/WIHD/WIHD&M/WIHL AND WIH 17-67 SERIES WH/WIH/WIHD/WIHD&M/WIHL AND WIH 17-67 SERIES Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect

More information

COMMERCIAL GAS DRYER

COMMERCIAL GAS DRYER COMMERCIAL GAS DRYER MODELS CGM2941TQ0 CGM2941TQ1 07 08 Litho in U.S.A. (LT)(mek) c 2008 WHIRLPOOL CORPORATION Part No. Rev. B BULKHEAD PARTS (White) (White) 2 BULKHEAD PARTS 1 Literature Parts 8563800

More information

SOLI TANKLESS PRODUCT GUIDE

SOLI TANKLESS PRODUCT GUIDE SOLI TANKLESS PRODUCT GUIDE SAVE ENERGY. Energy-efficient, plentiful, and endless supply of hot water. SAVE SPACE. Compact size and wall-mounted to free up valuable floor space. SAVE MONEY. The smart

More information

OPERATING, INSTALLATION AND SERVICE MANUAL

OPERATING, INSTALLATION AND SERVICE MANUAL OPERATING, INSTALLATION AND SERVICE MANUAL COMMERCIAL GAS WATER HEATER WITH FLUE DAMPER AND ELECTRIC IGNITION SYSTEM WITHOUT FAN MOTOR REQUIRES 120V A.C. POWER SUPPLY WARNING: If the information in these

More information

Water Heaters. Use & Care Manual. Electric Point of Use IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Water Heaters. Use & Care Manual. Electric Point of Use IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS Electric Point of Use Water Heaters LISTED 786H IMPORTANT SAFETY INSTRUCTIONS Printed in USA Use & Care Manual With Installation Instructions for the Installer The purpose of this manual is twofold: one,

More information