SOLI TANKLESS PRODUCT GUIDE

Size: px
Start display at page:

Download "SOLI TANKLESS PRODUCT GUIDE"

Transcription

1 SOLI TANKLESS PRODUCT GUIDE

2

3 SAVE ENERGY. Energy-efficient, plentiful, and endless supply of hot water. SAVE SPACE. Compact size and wall-mounted to free up valuable floor space. SAVE MONEY. The smart choice that will save you a substantial amount of energy. A. O. Smith has delivered innovative hot water solutions for more than 7 years and is sold exclusively by plumbing wholesalers and contractors. A. O. Smith s selection of residential and commercial tank-type, tankless, hybrid water heaters, boilers and storage tanks is unmatched for quality and diversity. Anywhere hot water is needed, A. O. Smith provides an energy-efficient solution with long-lasting value for years after installation. A. O. Smith stands behind its products and customers with world-class service, combining cutting-edge technology with committed people who take pride in being the very best. A. O. Smith is headquartered in Ashland City, Tennessee, home of the world s largest water heater factory. The A. O. Smith network includes five manufacturing facilities in North America, plus plants in Nanjing, China and Veldhoven, Netherlands.

4 TANKLESS ADVANTAGE HOW IT WORKS The Process: A hot water tap is opened. The opened tap allows water to flow through the water heater. An internal water flow sensor detects this flow. Upon flow detection, the flow sensor sends the activation signal to the computer board. The computer automatically ignites the burner. As water flows through the heat exchanger, it absorbs heat from the burner. By the time the water exits the heater, it has reached the designated set temperature. When the hot water tap is closed, the water heater automatically turns off. ENDLESS HOT WATER * Heating water only as it s being used means you will never run out of hot water again. After the few seconds it takes for the water to reach the designated set temperature, our water heaters will continually provide a steady flow of hot water for as long as your application needs it. *A. O. Smith tankless water heaters provide endless hot water when sized appropriately for your home s needs. ENERGY CONSERVATION Provides you with continuous hot water in one of the most energy-efficient ways possible. Conventional tank-type water heaters will heat and store a set volume of water, regardless of whether someone is using that hot water or not. Because our water heaters only activate when hot water is being used, no standby energy losses are incurred, providing efficient heating while conserving energy. COMPACT SIZE On top of all this, an A. O. Smith tankless water heater takes up much less space than your conventional tank-type water heater or boiler. With no tank or boiler to steal valuable storage space, A. O. Smith s wall-mount design allows for additional storage and flexibility. 1

5 SAFETY At A. O. Smith, we place the safety and reliability of our products above all else. By incorporating technologically advanced safety features into every model, we provide the assurance and peace of mind that can only come from an A. O. Smith quality product. Air-Fuel Ratio (AFR) Sensor A. O. Smith s unique AFR sensor monitors and maintains proper combustion at all times. Together with the onboard computer, this system will adjust the fan motor speed to ensure that air and fuel have a proper mixture ratio, minimizing emissions and maximizing efficiency. Additional Safety Features Freeze Protection: Every heater in A. O. Smith s tankless lineup has an internal freeze protection system, which is rated to protect the heaters when installed in sub-freezing conditions. This system works to keep water temperatures within the heat exchanger from falling below a certain level, preventing freeze damage. Hi-Limit Switch: Ensures that water temperatures do not exceed safe levels. Before the water temperature can even reach these unsafe levels, the hi-limit switch activates by disengaging the gas valves, effectively shutting down the water heater. Overheat Cutoff Fuse: Ensures that there are no breaches in the heat exchanger drum. In cases where enough physical damage might have been done to the water heater to lead to a breach in the heat exchanger drum, the overheat cutoff fuse reacts by shutting down the water heater if the surface of the heat exchanger retains too much heat. 2

6 DURABILITY HEAT EXCHANGER WITH COMMERCIAL-GRADE COPPER Only A. O. Smith incorporates true commercial-grade heat exchangers in our tankless heaters. NOTE: 51 Series, 51U Series, 54H Series and 91 Series non-asme models. All aspects of the heat exchanger are designed to add the durability and reliability that is vital to any successful commercial organization or business. Commercial-Grade Copper Alloy Our commercial-grade copper is a heat-resistant copper alloy, with additive elements that make it much stronger and harder than the standard C122 copper used in most other heat exchangers. Our commercial-grade copper has 8 times the tensile strength of regular copper. Even at high temperatures, our commercial-grade copper maintains a fine grain and high Commercial-Grade Copper Tubing strength. Commercial-grade copper provides resistance to the damaging effects of erosion that can cause heat exchangers to leak..16" (.4mm) A thinner drum strains more under heat stress.2" (.5mm) drum.16" (.4mm) water drum coil water drum coil.2" (.5mm) Drum Thickness water During every ignition cycle, thermal expansion causes all heat exchangers to undergo heat stress. After the thousands of ON/OFF cycles typically seen in a commercial application, this heat stress can prove damaging. This is why the heat exchangers in our commercial and light commercial products utilize drums that are 25% thicker, water ensuring the longevity of our products. A thicker drum creates less strain on the heat exchanger. 25% Thicker drum drum coil drum coil A thicker drum creates less strain on the heat exchanger A thicker drum creates less strain on the heat exchanger. water water drum coil drum coil water drum coil 25% Thicker drum water drum coil r drum creates less strain on the heat exchanger. 3

7 WATER VALVES Making true commercial-grade water heaters involves more than just redesigning our heat exchangers every internal component has to measure up to A. O. Smith s commercial standards. Just like our advanced heat exchangers, the longevity and functionality of components such as our water valves and flow sensors are also of great importance. Our commercial water heaters (51/U, 54H & 91 series) feature a bypass and flow adjustment valve, which not only provide the optimal control and precision essential for commercial usage, but also offer the durability needed to handle tough, high-volume conditions. Stepper Motor Water Valves Bypass Valve - 51/U and 54H Models Flow Adjustment - 51/U and 54H Models 4

8 SECONDARY HEAT EXCHANGER 316L STAINLESS STEEL (CONDENSING MODELS ONLY) The secondary condensing heat exchanger is made of high-quality 316L stainless steel. This is where the rest of the heat transfer occurs. Due to the lower temperature acidic condensation occurs, and stainless steel is required in order to avoid corrosion. For condensing heat exchangers, it is more suitable to use 316L stainless steel because of the extreme environment (heat, acidic condensation, chloride) that the material is subjected to. Secondary HX-Stainless Steel 316L PRIMARY HEAT EXCHANGER: COPPER VS. STAINLESS STEEL Bypass Valve Hot Water Outlet Flow Sensor Drum Coil Cold Water Inlet Flow Adjustment Valve Primary HX Commerical-Grade Copper Heat transfers 25 times more readily through copper than stainless steel. Consequently, for the same amount of heat transfer, stainless steel heat exchangers need to be larger than copper heat exchangers, leading to a larger pressure loss. At higher temperatures, it is the nature of stainless steel to become prone to a number of problems not usually experienced at room temperature. It is vulnerable to pitting corrosion and stress corrosion cracking (SCC). Stainless steel is NOT better for durability because it is harder. Hardness causes the material to become brittle. Stainless steel will crack after numerous cycles of thermal expansion/contraction, especially with chloride in the water. Copper heat exchangers are less brittle and better suited for expansion/ contraction without cracking. In a dual heat exchanger design, corrosion is not a big concern in the non-condensing primary heat exchanger because no condensation forms on the exterior of the pipes. Stainless steel is unnecessary for this stage. Note: 14, 24 and 34 condensing line units use C122 copper and do not have a bypass valve * Diagram represents 54H 5

9 WATER FLOW Condensation can build up over time in any heat exchanger, causing damage and premature leaks. A. O. Smith s commercial models (91 series) include condensation reduction features that safeguard against these types of damaging effects. Finned Coil (9%-95% of total heat absorbed) Better Water Pathway Design By redesigning and redirecting the flow of water, the temperature of the heat exchanger drum and finned coils stay elevated above dew point, making it much more difficult for condensation to build. Fin Pitch By widening the pitch of the heat exchanger fins, not only do we improve durability by reducing occurrences of blockage, we also maintain higher temperatures on the upper finned coils. Keeping these coils at elevated temperatures reduces the likelihood of condensation buildup. Drum Coil (5%-1% of total heat absorbed) Hot Water Outlet (1% heat absorbed) No condensation buildup on drum coil Burner M Bypass Valve (51/U, 54H & 91) Flow Sensor Cold Water Inlet FIN 6

10 BASIC SIZING GUIDELINES The flow rate capacity of tankless water heaters depends on the temperature difference between the desired output and incoming water temperature. The flow rate comparison chart and table shown here summarize the flow rate charts found in the specifications of each model. A. O. Smith water heaters are sized according to the peak flow rate requirements, worst-case temperature-rise scenarios, and types of applications. Once these factors have been determined, refer to either the flow rate comparison here or the flow rate charts found in each model s specifications. Select the appropriate water heater as well as the amount of water heaters required. Application designers/engineers can decide whether to size for full flow, expected flow, or utilize probability models such as the modified Hunter Curve. For large scale applications such as hotels, apartment complexes and large restaurants, Hunter Curves are commonly used to estimate the peak flow rate demand when given the total amount of fixture units within an application. It is up to the application designer/engineer to determine the amount of fixture units within any given application. MATCH THE UNIT TO YOUR NEEDS Warmer Climates 7 F Incoming Groundwater Temperature Cooler Climates 5 F Incoming Groundwater Temperature Capacity - Number of Shower Heads (Assuming the set point temperature is 12 F ) Non-Condensing Units ATI/O-11/U 2.5 Showers 1.5 Showers ATI/O-31/U 3.5 Showers 2.5 Showers ATI/O-51/U 3.5 Showers 2.5 Showers Condensing Units ATI/O-14H 2.5 Showers 1.5 Showers ATI/O-24H 3.5 Showers 2.5 Showers ATI/O-34H 4 Showers 2.5 Showers ATI/O-54H 4.5 Showers 3 Showers Commercial Unit ATI/O-91 7 Showers 5 Showers 7

11 FLOW RATE GUIDE Temperature Rise vs. Gallons per Minute Temp Rise 11/U Series 31/U Series 51/U Series 14H Series 24H Series 34H Series 54H Series 91 Series Flow rate is determined by temperature rise. To determine your temperature rise, subtract the incoming water temperature from the set output temperature. All units are factory set to 12 F or 122 F but can be changed. Example of Hunter Curves for Sizing Large Applications Comparison of Flow Rates vs. Temperature Rise Hunter Curves for Sizing Large Applications Flow Rate (gpm) Gallons Per Minute Fixture Units Temperature Rise ( F) Restaurants Hospitals, Nursing Homes, Dormitories, Hotels & Motels Apartments & Houses Office Buildings & Schools 91 SERIES 51/U SERIES 54H SERIES 34H SERIES 24H SERIES 31/U SERIES 14H SERIES 11/U SERIES 8

12 11 SERIES NON-CONDENSING The 11 Series is great for apartments, one bath homes in cold climates, condos and summer cabins. Remote control included as a standard feature. ATI-11-NI ATO-11-NE Dimensions 4" (11 mm) 13-3/4" (35mm) 4" (11 mm) 1" (254mm) 13-3/4" (35mm) 1-3/4" (45mm) 1" (254mm) 1-3/4" (45mm) 1-3/4" (45mm) 1-3/4" (45mm) 4" (12mm) 4" (12mm) 21-3/8" (544mm) 2-1/4" (52mm) 21-3/8" (544mm) 2-1/4" (52mm) 2-1/4" (56mm) 2-1/4" (56mm) 2-1/4" (57mm) 2-1/4" (57mm) 1-7/8" (47mm) 1-7/8" (47mm) COLD 3-1/8" (79mm) HOT 5-1/4" (133mm) COLD 3-1/8" (79mm) HOT 5-1/4" (133mm) 12V 1-3/8" (36mm) GAS 4-7/8" (124mm) 12V 1-3/8" (36mm) GAS 4-7/8" (124mm) 1" (26mm) 2-1/4" (56 mm) 1" COLD (26mm) 3-7/8" (98mm) 2-1/4" GAS (56 mm) COLD 4-7/8" (123mm) 3-7/8" 12V(98mm) GAS 4-7/8" (124mm) 4-7/8" HOT (123mm) 12V 7-3/4" (196mm) 4-7/8" (124mm) HOT 7-3/4" (196mm) 9

13 Specifications Provides a variety of installation options: indoor, outdoor, and direct vent. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts Low NOx emissions **Refer to for further warranty details. ATI-11-NI includes both a remote control and power cord as standard features. Installation Type Dimension Indoor, Outdoor, Direct Vent 2-1/4" (H) X 13-3/4" (W) X 7-3/4" (D), Weight: 33 lbs Electric 12 V 73 W /.73 A (Operation) 6 W /.5 A (Standby) 111 W /.93 A (Freeze-Protection) Ignition Noise Level Electronic Ignition 53 db at Max output Fuel NG LP Min. Input 19,5 BTU/h 19,5 BTU/h Gas Consumption Max. Input 14, BTU/h 14, BTU/h Energy Factor Min 5." W.C. Min 8." W.C. Gas Pressure Max 1.5" W.C. Max 14." W.C. Flow Rate 6.6 GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition Hot/Cold/Gas Connection Coil Capacity Water Pressure Multiple Unit Installation 11 Temperature Settings 3/4" NPT.2 Gallons Pressure Only Relief Valve Requires (Min 14, btu/h, 15 PSI) PSI 4 psi or above recommended for max. flow Easy-Link System N/A N/A Multi-Unit System N/A N/A Dipswitches 113 F 122 F (default) 131 F 14 F With remote (max. distance 15 from heater, non-polarized 2 gauge wiring.) 99 F to 167 F (16 options), 122 F Default Factory Setting 11U: Pressure Loss 11: Flow Rate vs. Temperature Rise 11: Pressure Loss 11: Flow Rate vs. Temperature Rise Pressure Loss (psi) Flow Rate (gpm) Head (ft) Clearance Clearances to Combustible and Non-Combustible Surfaces Indoor Installations Outdoor Installations Front 4 (Recommended 24 for maintenance) 1

14 31 SERIES The 31 features a max flow rate of 8. gpm, providing enough hot water to run three showers at the same time. Remote control included as a standard feature. ATI-31-NI ATO-31-NE Dimensions 13-3/4" (35mm) 13-3/4" (35mm) 4" (11 mm) 1" (254mm) 1" (254mm) 1-3/4" (45mm) 1-3/4" (45mm) 4" (11 mm) 1-3/4" (45mm) 1-3/4" (45mm) 4-3/8" (113mm) 4-3/8" (113mm) 21-3/8" (544mm) 2-1/4" (52mm) 21-3/8" (544mm) 2-1/4" (52mm) 1-3/8" (36mm) 1-3/8" (36mm) 19-3/8" (493mm) 19-3/8" (493mm) 1-5/8" (43mm) 1-5/8" (43mm) 1-7/8" (47mm) 1-7/8" (47mm) COLD 3-1/4" (84mm) HOT 5-1/4" (133mm) COLD 3-1/4" (84mm) HOT 5-1/4" (133mm) 12V 1-3/8" (36mm) GAS 4-7/8" (124mm) 12V 1-3/8" (36mm) GAS 4-7/8" (124mm) 1" (26mm) COLD 2-7/8" (71mm) 1" (26mm) 12VAC 3-7/8" (99mm) COLD 2-7/8" (71mm) GAS 5-1/4" (135mm) 12VAC 3-7/8" (99mm) HOT 6-1/2" (164mm) GAS 5-1/4" (135mm) 9-1/2" (241mm) HOT 6-1/2" (164mm) 9-1/2" (241mm) 11

15 Specifications Provides a variety of installation options: indoor, outdoor, and direct vent. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts Low NOx emissions **Refer to for further warranty details. ATI-31-NI includes both a remote control and power cord as standard features. Installation Type Dimension Indoor, Outdoor, Direct Vent 2-1/4" (H) X 13-3/4" (W) X 9-1/2" (D), Weight: 38 lbs Electric 12 V 88 W /.73 A (Operation) 6 W /.5 A (Standby) 111 W /.93 A (Freeze-Protection) Ignition Noise Level Electronic Ignition 53 db at Max output Fuel NG LP Min. Input 11, BTU/h 11, BTU/h Gas Consumption Max. Input 19, BTU/h 19, BTU/h Energy Factor Min 5." W.C. Min 8." W.C. Gas Pressure Max 1.5" W.C. Max 14." W.C. Flow Rate Hot/Cold/Gas Connection Coil Capacity Water Pressure Multiple Unit Installation 31 Temperature Settings 8. GPM 3/4" NPT Values based on factory testing..4 GPM required for continuous fire after initial ignition.2 Gallons Pressure Only Relief Valve Requires (Min 19, btu/h, 15 PSI) PSI 4 psi or above recommended for max. flow Easy-Link System N/A N/A Multi-Unit System N/A N/A Dipswitches 113 F 122 F (default) 131 F 14 F With remote (max. distance 15 from heater, non-polarized 2 gauge wiring.) 99 F to 167 F (16 options), 122 F Default Factory Setting 31: Flow 31: Rate Flow vs. Rate Temperature vs. Temperature Rise Rise 31: Pressure 31: Pressure Loss Loss Pressure Loss (psi) Head (ft) Flow Rate (gpm) Clearance Clearances to Combustible and Non-Combustible Surfaces Indoor Installations Outdoor Installations Front 4 (Recommended 24 for maintenance) 12

16 51 SERIES The 51 series is well suited for residential/commercial applications such as small restaurants and beauty salons. Utilizing commercialgrade copper alloy for the heat exchanger tubing, the 51 series is also suitable for heavier residential usages such as combination space heating and domestic recirculation systems. Remote control included as a standard feature. ATI-51-NI ATO-51-NE Dimensions 13-3/4" (35mm) 13-3/4" 4" (35mm) (11 mm) 1" (254mm) 1" (254mm) 1-3/4" (45mm) 1-3/4" (45mm) 4" (11 mm) 1-3/4" (45mm) 1-3/4" (45mm) 4-3/8" (113mm) 4-3/8" (113mm) 21-3/8" (544mm) 2-1/4" (52mm) 21-3/8" (544mm) 2-1/4" (52mm) 1-3/8" (36mm) 1-3/8" (36mm) 19-3/8" (493mm) 19-3/8" (493mm) 1-5/8" (43mm) 1-5/8" (43mm) 1-7/8" (47mm) 1-7/8" (47mm) COLD 3-1/4" (84mm) HOT 5-1/4" (133mm) COLD 3-1/4" (84mm) HOT 5-1/4" (133mm) 12V 1-3/8" (36mm) GAS 4-7/8" (124mm) 12V 1-3/8" (36mm) GAS 4-7/8" (124mm) 1" (26mm) COLD 2-7/8" (71mm) 1" (26mm) 12VAC 3-7/8" (99mm) COLD 2-7/8" (71mm) GAS 5-1/4" (135mm) 12VAC 3-7/8" (99mm) HOT 6-1/2" (164mm) GAS 5-1/4" (135mm) 9-1/2" (241mm) HOT 6-1/2" (164mm) 9-1/2" (241mm) 13

17 Specifications Thicker heat exchanger drum and utilizes commercial-grade copper (heatresistant) copper for the heat exchanger tubing. Provides a variety of installation options: indoor, outdoor, and direct vent. Includes a pump control port, ensuring efficient operation of all circulation pumps. Easy-Link System capable up to 4 units. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts Commercial Use: 1 Years limited heat exchanger, 5 Years limited parts **Refer to for further warranty details. ATI-51-NI includes both a remote control and power cord as standard features. Installation Type Dimension Indoor, Outdoor, Direct Vent 2-1/4 (H) X 13-3/4 (W) X 9-1/2 (D), Weight: 39 lbs Electric 12 V 9 W /.75 A 6 W /.5 A 111 W /.93 A (Freeze-Protection) Ignition Noise Level Electronic Ignition 55 db at Max output Fuel NG LP Min. Input 11, BTU/h 11, BTU/h Gas Consumption Max. Input 199, BTU/h 199, BTU/h Energy Factor Min 5." W.C. Min 8." W.C. Gas Pressure Max 1.5" W.C. Max 14." W.C. Flow Rate Hot/Cold/Gas Connection Coil Capacity Water Pressure Multiple Unit Installation 51 Temperature Settings 1. GPM 3/4" NPT Values based on factory testing..4 GPM required for continuous fire after initial ignition.2 Gallons Pressure Only Relief Valve Requires (Min 2, btu/h, 15 PSI) PSI 4 psi or above recommended for max. flow Easy-Link System Up to 4 units With no need for a system controller Multi-Unit System N/A N/A Dipswitches 14 F 113 F 122 F (default) 14 F With remote (max. distance 4 from heater, non-polarized 2 gauge wiring.) 1 F to 176 F (15 options), 122 F Default Factory Setting T-D2: Flow Rate vs. Temperature Rise 51: Flow Rate vs. Temperature Rise 51: Pressure Loss 51: Pressure Loss Flow Rate (gpm) Set temperature: 122 F or lower Set temperature: 131 F or higher Temperature Rise ( F) 14 Pressure Loss (psi) Set temperature: 122 F or lower Set temperature: 131 F or higher Flow Rate (gpm) Head (ft) Clearance Clearances to Combustible and Non-Combustible Surfaces Indoor Installations Outdoor Installations Front 4 (Recommended 24 for maintenance) 14

18 11U Series The 11U Series is great for apartments, one bath homes in cold climates, condos and summer cabins. Remote control included as a standard feature. Complies with SCAQMD Rule and other air quality management districts with similar NOx Emission requirements of 14 ng/j or 2 PPM. ATI-11U-NI ATO-11U-NE ULTRA-LOW NOx 2. Exterior view 11U Indoor (T-KJr2U-IN) 31U Indoor (T-K4U-IN) 51U Indoor (T-D2U-IN) Dimensions Front view Side view 3-5/8" (94 mm) 13-3/4" (35 mm) 1" (254 mm) 7" (18 mm) 4" (11 mm) 4-3/8" (113 mm) 2-1/4" (52mm) 1-3/8" (36 mm) 1" (26 mm) 12 VAC 3" (75 mm) GAS 5-1/4" (135 mm) COLD 6" (153 mm) HOT 6" (153 mm) 9-1/2" (241 mm) HOT 4-5/8" (119 mm) COLD 4-7/8" (124 mm) GAS 1-1/2" (38 mm) 13-1/8" (334 mm) 5-1/8" (13 mm) ) ) ) 2-1/4" (58 mm) 19-3/8" (493 mm) 1-7/8" (47 mm) HOT 4-5/8" (116 mm) 12 VAC 1-5/8" (4 mm) COLD 1-5/8" (41 mm) GAS 5" (127 mm) Top view Bo om view 15 HOT 5" (127 mm) 4-3/8" (113 mm)

19 Specifications Provides a variety of installation options: indoor, outdoor, and direct vent. Complies with Ultra-Low NOx regulations. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts **Refer to for further warranty details. Indoor models include both a remote control and power cord as standard features. Outdoor models include remote control as a standard feature. Installation Type Dimension Indoor, Outdoor, Direct Vent 2-1/4" (H) X 13-3/4" (W) X 9-1/2" (D), Weight: 37 lbs Electric 12 V 52 W /.54 A (Operation) 5.4 W /.8 A (Standby) 131 W / 1.1 A (Freeze-Protection) Ignition Noise Level Electronic Ignition IN: 54 db OS: 58 db at Max output Fuel NG Gas Consumption Min. Input 15, BTU/h Max. Input 14, BTU/h Energy Factor.82 Gas Pressure Min 5." W.C. Max 1.5" W.C. Flow Rate 6.6 GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition Hot/Cold/Gas Connection 3/4" NPT Coil Capacity.2 Gallons Water Pressure PSI Pressure Only Relief Valve Requires (Min 14, btu/h, 15 PSI). 4 psi or above recommended for max. flow Multiple Unit Easy-Link System N/A N/A Installation Multi-Unit System N/A N/A 11U Temperature Settings Dipswitches 12 F (default) 14 F With remote (max. distance 4 from heater, non-polarized 2 gauge wiring.) 1 F to 14 F (9 options), 12 F Default Factory Setting 11U: Flow Rate vs. Temperature Rise 11U: 11U: Pressure Pressure Loss Loss 11: Flow Rate vs. Temperature Rise Pressure Loss (psi) Flow Rate (gpm) Head (ft) Clearance Clearances to Combustible and Non-Combustible Surfaces Indoor Installations Side 3 Outdoor Installations Side 3 Front 4 (Recommended 24 for maintenance) Side 3 Side 3 16

20 31U Series The 31U features a max flow rate of 8. gpm providing enough hot water to run three showers at the same time. Remote control included as a standard feature. Complies with SCAQMD Rule and other air quality management districts with similar NOx Emission requirements of 14 ng/j or 2 PPM. ATI-31U-NI ATO-31U-NE 2. Exterior view 11U Indoor (T-KJr2U-IN) 31U Indoor (T-K4U-IN) 51U Indoor (T-D2U-IN) Dimensions Front view Side view 3-5/8" (94 mm) 13-3/4" (35 mm) 1" (254 mm) 7" (18 mm) 4" (11 mm) 4-3/8" (113 mm) 2-1/4" (52mm) 1-3/8" (36 mm) 2-1/4" (58 mm) 19-3/8" (493 mm) 1-7/8" (47 mm) HOT 4-5/8" (116 mm) 12 VAC 1-5/8" (4 mm) COLD 1-5/8" (41 mm) GAS 5" (127 mm) 1" (26 mm) 12 VAC 3" (75 mm) GAS 5-1/4" (135 mm) COLD 6" (153 mm) HOT 6" (153 mm) 9-1/2" (241 mm) HOT 4-5/8" (119 mm) Top view COLD 4-7/8" (124 mm) GAS 1-1/2" (38 mm) Bo om view 13-1/8" (334 mm) 5-1/8" (13 mm) 17 OT 5" (127 mm) 3/8" (113 mm)

21 Specifications Provides a variety of installation options: indoor, outdoor, and direct vent. Complies with Ultra-Low NOx regulations. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts **Refer to for further warranty details. Indoor models include both a remote control and power cord as standard features. Outdoor models include remote control as a standard feature. Installation Type Dimension Indoor, Outdoor, Direct Vent 2-1/4 (H) X 13-3/4 (W) X 9-1/2 (D), Weight: 37 lbs Electric 12 V 76 W /.8 A (Operation) 6 W /.8 A (Standby) 131 W / 1.1 A (Freeze-Protection) Ignition Noise Level Electronic Ignition IN: 54 db OS: 58 db at Max output Fuel NG Gas Consumption Min. Input 15, BTU/h Max. Input 19, BTU/h Energy Factor.82 Gas Pressure Min 5." W.C. Max 1.5" W.C. Flow Rate 8. GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition Hot/Cold/Gas Connection 3/4" NPT Coil Capacity.2 Gallons Water Pressure PSI Pressure Only Relief Valve Requires (Min 19, btu/h, 15 PSI). 4 psi or above recommended for max. flow Multiple Unit Easy-Link System N/A N/A Installation Multi-Unit System N/A N/A 31U Temperature Settings Dipswitches 12 F (default) 14 F With remote (max. distance 4 from heater, non-polarized 2 gauge wiring.) 12 F to 14 F (9 options), 12 F Default Factory Setting 31U: 31: Flow Flow Rate Rate vs. vs. Temperature Rise Rise 31U: 31: Pressure Pressure Loss Loss Pressure Loss (psi) Head (ft) Flow Rate (gpm) Clearance Clearances to Combustible and Non-Combustible Surfaces Indoor Installations Side 3 Outdoor Installations Side 3 Front 4 (Recommended 24 for maintenance) Side 3 Side 3 18

22 51U Series The 51U series is well suited for residential/commercial applications such as small restaurants and beauty salons. Utilizing commercial-grade copper alloy for the heat exchanger tubing, the 51U series is also suitable for heavier-residential usages such as combination space heating and domestic recirculation systems. Remote control included as a standard feature. ATI-51U-NI ATO-51U-NE 2. Exterior view 11U Indoor (T-KJr2U-IN) 31U Indoor (T-K4U-IN) 51U Indoor (T-D2U-IN) Dimensions Front view Side view 3-5/8" (94 mm) 13-3/4" (35 mm) 1" (254 mm) 7" (18 mm) 4" (11 mm) 4-3/8" (113 mm) 2-1/4" (52mm) 1-3/8" (36 mm) 2-1/4" (58 mm) 19-3/8" (493 mm) 1-7/8" (47 mm) HOT 4-5/8" (116 mm) 12 VAC 1-5/8" (4 mm) COLD 1-5/8" (41 mm) GAS 5" (127 mm) 1" (26 mm) 12 VAC 3" (75 mm) GAS 5-1/4" (135 mm) COLD 6" (153 mm) HOT 6" (153 mm) 9-1/2" (241 mm) Top view Bo om view 19 HOT 4-5/8" (119 mm) (127 mm) COLD 4-7/8" (124 mm) GAS 1-1/2" (38 mm) 113 mm) 13-1/8" (334 mm) 5-1/8" (13 mm)

23 Specifications Thicker heat exchanger drum and utilizes commercial-grade copper (heat-resistant) copper for the heat exchanger tubing. Provides a variety of installation options: indoor, outdoor, and direct vent. Complies with SCAQMD Rule and other air quality management districts with similar NOx Emission requirements of 14 ng/j or 2 PPM. Easy-Link System capable up to 4 units. Multi- Link system capable up to 2 units. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts Commercial Use: 1 Years limited heat exchanger, 5 Years limited parts **Refer to for further warranty details. Indoor models include both a remote control and power cord as standard features. Outdoor models include remote control as a standard feature. Installation Type Dimension Indoor, Outdoor, Direct Vent 2-1/4" (H) X 13-3/4" (W) X 9-1/2" (D), Weight: 39 lbs Electric 12 V 82 W /.86 A (Operation) 7 W /.9 A (Standby) 132 W / 1.1 A (Freeze-Protection) Ignition Noise Level Fuel Electronic Ignition IN: 54 db OS: 58 db at Max output NG Gas Consumption Min. Input 15, BTU/h Max. Input 199, BTU/h Energy Factor.82 Gas Pressure Min 5." W.C. Max 1.5" W.C. Flow Rate 1. GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition Hot/Cold/Gas Connection 3/4" NPT Coil Capacity.2 Gallons Water Pressure PSI Pressure Only Relief Valve Requires (Min 2, BTUs. 15 PSI). 4 psi or above recommended for max. flow Multiple Unit Easy-Link System Up to 4 units With no need for a system controller Installation Multi-Unit System Up to 2 units Multi-Controller (9835) 51U Temperature Settings Dipswitches 12 F (default) 14 F 51U: T-D2: Flow Flow Rate Rate vs. vs. Temperature Temperature Rise Rise 51U: 51: Pressure Loss Loss Flow Rate (gpm) Set temperature: 13 F or lower Set temperature: 135 F or higher Temperature Rise ( F) 14 With remote (max. distance 4 from heater, non-polarized 12 gauge wiring.) 1 F to 16 F (13 options), 12 F Default Factory Setting Set temperature: 13 F or lower Set temperature: 135 F or higher Flow Rate (gpm) Head (ft) Clearance Clearances to Combustible and Non-Combustible Surfaces Indoor Installations Side 3 Side 3 Outdoor Installations Side 3 Side 3 Front 4 Front 4 (Recommended 24 for maintenance) (Recommended 24 for maintenance) Side 3 Side 3 Side 3 Side 3 2

24 14H Series The 14H Series is a high efficiency, ultra-low NOx condensing model with a.93 Energy Factor, allowing for the use of 3 or 4 PVC venting or Category IV stainless steel. ATI-14H-NIH ATO-14H-NEH CONDENSING Dimensions INDOOR MODEL Front view Side view 13-7/8" (352mm) 1" (254mm) 6-1/4" (158.5mm) 4" (12mm) 4" (12mm) 1-13/16" (274.6mm) 1-5/16" (262.2mm) 6" (152.1mm) /16" (64.8mm) 2-3/4" (7.2mm) 24" (69.4mm) 22-7/8 (58mm) Hot 4-3/4" (121.1mm) Condensate drain port 5-1/16" (129.1mm) 5-3/8" (137mm) 7-1/16" (18mm) Cold 1/2" (13.3mm) 12VAC 3-1/16" (77mm) Gas 4/1/2" (113.7mm) 1" (25.5mm) Condensate drain port 3-1/4" (82.1mm) Gas 4-1/8" (15.4mm) Hot 6-1/2" (164.6mm) Cold 7" (178.5mm) 12VAC 7-3/4" (196.5mm) Bo om view Top view 13-5/16" (338.1mm) 21 HOT 6-1/2" (165.3mm) Condensate drain port 3-1/4" (82.8mm) 6.1mm) 7-1/16" (179.2mm) LD 7-3/4" (197.2mm) AC 6" (152.1mm)

25 Specifications Provides a variety of installation options: indoor, outdoor and power direct vent design. Complies with SCAQMD Rule and other air quality management districts with similar NOx Emission requirements of 14 ng/j or 2 PPM. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts **Refer to for further warranty details. Indoor model includes a built-in temperature controller and advanced diagnostics to simplify troubleshooting. Outdoor model includes a wall mount temperature remote controller and advanced diagnostics for troubleshooting. Installation Type Dimension Indoor, Outdoor, SCH 4 PVC Direct Vent or Category IV Stainless Steel 22-7/8" (H) X 13-7/8" (W) X 1-3/4" (D), Weight: 44 lbs Electric 12 V 54 W /.7 A (Operation) 3 W /.5 A (Standby) 224 W / 2 A (Freeze-Protection) Ignition Electronic Ignition Noise Level IN: 47 db OS: 52 db at Max output Fuel NG LP Gas Consumption Min. Input 15, BTU/h 15, BTU/h Max. Input 12, BTU/h 12, BTU/h Energy Factor Gas Pressure Min 5." W.C. Min 8." W.C. Max 1.5" W.C. Max 14." W.C. Flow Rate 6.6 GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition Hot/Cold/Gas Connection 3/4 NPT / 1/2" NPT Coil Capacity.5 Gallons Water Pressure PSI Pressure Only Relief Valve Requires (Min 12, btu/h, 15 PSI). 4 psi or above recommended for max. flow Easy-Link System N/A N/A Multiple Unit Installation Multi-Unit System N/A N/A 14H Temperature Settings Built In / without remote 12 F (Default) 14 F With remote (max. distance 4 from heater, non-polarized 2 gauge wiring.) 1 F to 14 F with 5 F intervals (9 options), 12 F Default Factory Setting 14H: 14H: Flow Flow Rate Rate vs. vs. Temperature Rise Rise 14H: 14H: Pressure Loss Flow Rate (gpm) Temperature Rise ( F) Pressure Loss (psi) Flow Rate (gpm) Head (ft) Clearance Clearances to Combustible and Non-Combustible Surfaces Direct Vent Installations Outdoor Installations Front 4 22

26 24H Series The 24H series offers high efficiency Ultra-Low NOx condensing technology allowing for the use of 3 PVC venting and has clearance to combustibles. ATI-24H-NIH ATO-24H-NEH Dimensions 4" (12 mm) Female 17-3/4" (45 mm) 7" (18 mm) 4" (11 mm) 4" (12 mm) Female 11-1/4" (285 mm) 5-3/4" (147 mm) 24-7/8" (631 mm) 23-5/8" (6 mm) 6-1/4" (159mm) 22-1/22" (57 mm) Exhaust 2-5/8" (65 mm) Intake 2-5/8" (68 mm) 1-3/4" (272mm) HOT 4-3/4" (12 mm) Drain port 6-3/4" (17 mm) COLD 5/8" (17 mm) 12 VAC 3" (77 mm) GAS 5-3/4" (147 mm) Condensate drain port 7-1/2" (189 mm) 1/2 (13 mm) GAS 5-1/8" (131 mm) HOT 5-1/2" (14 mm) Drain port 6" (152 mm) COLD 6-3/4" (172 mm) 12 VAC 6-7/8" (174 mm) Condensate drain port 7-7/8" (199 mm) HOT 4-3/4" (12 mm) Condensate drain port 7-1/2" (189 mm) GAS 5-7/8" (147 mm) 12 VAC 3" (77 mm) 23 HOT 5-1/2" (14 mm) 12 VAC 6-7/8" (174 mm) GAS 5-1/8" (131 mm) COLD 6-3/4" (172 mm) Condensate drain port 7-7/8" (199 mm) 5-3/4" (147 mm) 17-5/8" (448 mm) COLD 5/8" (17 mm) 6-1/4" (159 mm)

27 Bottom 12 Bottom 12 Bottom 12 Bottom 12 Specifications Provides a variety of installation options: indoor, outdoor, and direct vent. Complies with SCAQMD Rule and other air quality management districts with similar NOx Emission requirements of 14 ng/j or 2 PPM. Warranty Information** Residential Use: 15 years limited heat exchanger, 5 Years limited parts **Refer to for further warranty details. Indoor model includes a built-in temperature controller and advanced diagnostics to simplify troubleshooting. Outdoor model includes a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting. Installation Type Dimension Indoor, Outdoor, SCH 4 PVC Direct Vent, Category IV Stainless Steel 23-5/8" (H) X 17-3/4" (W) X 11-1/4" (D), Weight: 58 lbs Electric 12 V 73 W /.61 A (Operation) 3 W /.3 A (Standby) Ignition Electronic Ignition 174 W / 1.5 A (Freeze- Protection) Noise Level IN: 5 db OS: 53 db at Max output Fuel NG LP Gas Consumption Min. Input 15, BTU/h 13, BTU/h Max. Input 16, BTU/h 16, BTU/h Energy Factor Gas Pressure Min 5." W.C. Min 8." W.C. Max 1.5" W.C. Max 14." W.C. Flow Rate 6.6 GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition Hot/Cold/Gas Connection 3/4" NPT Coil Capacity.5 Gallons Water Pressure PSI Pressure Only Relief Valve Requires (Min 16, btu/h, 15 PSI). 4 psi or above recommended for max. flow Easy-Link System N/A N/A Multiple Unit Installation Multi-Unit System N/A N/A 24H Temperature Settings Built In / without remote 12 F (Default) 14 F With remote (max. distance 4 from heater, non-polarized 2 gauge wiring.) 1 F to 14 F with 5 F intervals (9 options), 12 F Default Factory Setting 24H: 24H: Flow Rate Flow Rate vs. Temperature vs. Temperature Rise Rise 24H: 24H: Pressure Pressure Loss Loss Flow Rate (gpm) Pressure Loss (psi) Head (ft) Temperature Rise ( F) Flow Rate (gpm) Clearance Clearances to Combustible and Non-Combustible Surfaces Direct Vent Installations Top 12 Top 12 Back.5 Back.5 Outdoor Installations Top 36 Top 36 Back.5 Back.5 Front 4 Front 4 (Recommended 24 for maintenance) (Recommended 24 for maintenance) Front 24 Front 24 24

28 34H Series The 34H series offers high efficiency Ultra-Low NOx condensing technology allowing for the use of 3 PVC venting and has clearance to combustibles. Indoor models are certified up to 1,1 ft. altitude. ATI-34H-NIH ATO-34H-NEH Dimensions 4" (12 mm) Female 17-3/4" (45 mm) 7" (18 mm) 4" (11 mm) 4" (12 mm) Female 11-1/4" (285 mm) 5-3/4" (147 mm) 24-7/8" (631 mm) 23-5/8" (6 mm) 6-1/4" (159mm) 22-1/22" (57 mm) Exhaust 2-5/8" (65 mm) Intake 2-5/8" (68 mm) 1-3/4" (272mm) HOT 4-3/4" (12 mm) Drain port 6-3/4" (17 mm) COLD 5/8" (17 mm) 12 VAC 3" (77 mm) GAS 5-3/4" (147 mm) Condensate drain port 7-1/2" (189 mm) 1/2 (13 mm) GAS 5-1/8" (131 mm) HOT 5-1/2" (14 mm) Drain port 6" (152 mm) COLD 6-3/4" (172 mm) 12 VAC 6-7/8" (174 mm) Condensate drain port 7-7/8" (199 mm) HOT 4-3/4" (12 mm) Condensate drain port 7-1/2" (189 mm) GAS 5-7/8" (147 mm) 12 VAC 3" (77 mm) 25 HOT 5-1/2" (14 mm) 12 VAC 6-7/8" (174 mm) GAS 5-1/8" (131 mm) COLD 6-3/4" (172 mm) Condensate drain port 7-7/8" (199 mm) 5-3/4" (147 mm) 17-5/8" (448 mm) COLD 5/8" (17 mm) 6-1/4" (159 mm)

29 Bottom 12 Bottom 12 Bottom 12 Bottom 12 Specifications Provides a variety of installation options: indoor, outdoor, and direct vent. Complies with SCAQMD Rule and other air quality management districts with similar NOx Emission requirements of 14 ng/j or 2 PPM. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts **Refer to for further warranty details. Indoor model includes a built-in temperature controller and advanced diagnostics to simplify troubleshooting. Outdoor model includes a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting. Installation Type Dimension Indoor, Outdoor, SCH 4 PVC Direct Vent, Category IV Stainless Steel 23-5/8" (H) X 17-3/4" (W) X 11-1/4" (D), Weight: 58 lbs Electric 12 V 78 W /.65 A (Operation) 3 W /.3 A (Standby) 174 W / 1.5 A (Freeze-Protection) Ignition Noise Level Electronic Ignition 55 db at Max output Fuel NG LP Min. Input 15, BTU/h 13, BTU/h Gas Consumption Max. Input 18, BTU/h 18, BTU/h Energy Factor Min 5." W.C. Min 8." W.C. Gas Pressure Max 1.5" W.C. Max 14." W.C. Flow Rate Hot/Cold/Gas Connection Coil Capacity Water Pressure Multiple Unit Installation 34H Temperature Settings 8. GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition 3/4" NPT.5 Gallons Pressure Only Relief Valve Requires (Min 18, btu/h, 15 PSI) PSI 4 psi or above recommended for max. flow Easy-Link System N/A N/A Multi-Unit System N/A N/A Built In / without remote 12 F (Default) 14 F With remote (max. distance 4 from heater, non-polarized 2 gauge wiring.) 1 F to 14 F with 5 F intervals (9 options), 12 F Default Factory Setting 34H: Pressure Loss 34H: Flow 34H: Rate Flow vs. Rate Temperature vs. Temperature Rise Rise 34H: Pressure Loss Flow Rate (gpm) Pressure Loss (psi) Head (ft) Temperature Rise ( F) Flow Rate (gpm) Clearance Clearances to Combustible and Non-Combustible Surfaces Direct Vent Installations Top 12 Top 12 Back.5 Back.5 Outdoor Installations Top 36 Top 36 Back.5 Back.5 Front 4 Front 4 (Recommended 24 for maintenance) (Recommended 24 for maintenance) Front 24 Front 24 26

30 54H Series The 54H is well suited for residential/ commercial applications such as small restaurants and beauty salons. Complies with Ultra-Low NOx regulations. Utilizing commercial-grade copper alloy for the heat exchanger tubing, the 54H is also suitable for heavier residential usages such as combination space heating and domestic recirculation systems. Remote control included as a standard feature. Indoor models are certified up to 1,1 ft. altitude. ATI-54H-NIH ATO-54H-NEH Dimensions 4" (12 mm) Female 17-3/4" (45 mm) 7" (18 mm) 4" (11 mm) 4" (12 mm) Female 11-1/4" (285 mm) 5-3/4" (147 mm) 24-7/8" (631 mm) 23-5/8" (6 mm) 6-1/4" (159mm) 22-1/22" (57 mm) Exhaust 2-5/8" (65 mm) Intake 2-5/8" (68 mm) 1-3/4" (272mm) HOT 4-3/4" (12 mm) Drain port 6-3/4" (17 mm) COLD 5/8" (17 mm) 12 VAC 3" (77 mm) GAS 5-3/4" (147 mm) Condensate drain port 7-1/2" (189 mm) 1/2 (13 mm) GAS 5-1/8" (131 mm) HOT 5-1/2" (14 mm) Drain port 6" (152 mm) COLD 6-3/4" (172 mm) 12 VAC 6-7/8" (174 mm) Condensate drain port 7-7/8" (199 mm) HOT 4-3/4" (12 mm) Condensate drain port 7-1/2" (189 mm) GAS 5-7/8" (147 mm) 12 VAC 3" (77 mm) 27 OT 5-1/2" (14 mm) 2 VAC 6-7/8" (174 mm) AS 5-1/8" (131 mm) OLD 6-3/4" (172 mm) ondensate drain port -7/8" (199 mm) 5-3/4" (147 mm) 17-5/8" (448 mm)

31 Bottom 12 Bottom 12 Bottom 12 Bottom 12 Specifications Thicker heat exchanger drum and utilizes commercial-grade copper for the heat exchanger tubing. Provides a variety of installation options: outdoor, and direct vent. Complies with SCAQMD Rule and other air quality management districts with similar NOx Emission requirements of 14 ng/j or 2 PPM. Easy-Link System capable up to 4 units. Multi-Link System capable up to 2 units. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts Commercial Use: 1 Years limited heat exchanger, 5 Years limited parts **Refer to for further warranty details. Indoor model includes a built-in temperature controller and advanced diagnostics to simplify troubleshooting. Outdoor models includes a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting. 54H: Flow 54H: Rate Flow vs. Rate Temperature vs. Temperature Rise Rise Installation Type Dimension Indoor, Outdoor, SCH 4 PVC Direct Vent, Category IV Stainless Steel 23-5/8" (H) X 17-3/4" (W) X 11-1/4" (D), Weight: 59 lbs Electric 12 V 89 W /.74 A (Operation) 4 W /.4 A (Standby) 175 W / 1.5 A (Freeze-Protection) Ignition Electronic Ignition Noise Level IN: 51 db OS: 56 db at Max output Fuel NG LP Gas Consumption Min. Input 15, BTU/h 13, BTU/h Max. Input 199, BTU/h 199, BTU/h Energy Factor Gas Pressure Min 5." W.C. Min 8." W.C. Max 1.5" W.C. Max 14." W.C. Flow Rate 1. GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition Hot/Cold/Gas Connection 3/4" NPT Coil Capacity.5 Gallons Water Pressure PSI Pressure Only Relief Valve Requires (Min 2, btu/h, 15 PSI). 4 psi or above recommended for max. flow Easy-Link System Up to 4 units With no need for a system controller Multiple Unit Installation Multi-Unit System Up to 2 units Multiple-Unit Controller H Temperature Settings Built In / without remote 12 F (Default) 14 F With remote (max. distance 4 from heater, non-polarized 16 gauge wiring.) 1 F to 16 F with 5 F intervals (13 options), 12 F Default Factory Setting 54H: Pressure Loss 54H: Pressure Loss Set temperature: 125 F or lower Set temperature: 13 F or higher Pressure Loss (psi) Set temperature: 125 F or lower Set temperature: 13 F or higher Flow Rate (gpm) Head (ft) Clearance Clearances to Combustible and Non-Combustible Surfaces Direct Vent Installations Top 12 Top 12 Back.5 Back.5 Outdoor Installations Top 36 Top 36 Back.5 Back.5 Front Front 4 4 (Recommended for maintenance) for Front 4 Front 4 (Recommended (Recommended for maintenance) for maintenance) 28

32 91 Series The 91 Series, specifically designed for heavy-duty applications, is the largest A. O. Smith tankless heater yet and the most powerful (14.5 GPM max) in the tankless industry. The 91 Series is suitable for commercial applications (hotels, restaurants, government, convalescent homes, etc.) that require high demand and the most durable of heaters. Along with commercial-grade copper alloy, the 91 Series is the only commercial unit in the industry that offers a dual-combustion system, providing redundancy for added reliability. ATIO-91-NIEA Dimensions 29

33 Specifications Thicker heat exchanger drum and utilizes commercial-grade copper for the heat exchanger tubing. Incorporates a dual system for redundancy, providing added assurance that the 91 Series will remain operational. Includes an internal pump control port. Easy-Link System capable up to 4 units. Multi- Unit System capable up to 1 units. An ASME version of the 91 Series is also available.* Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts Commercial Use: 1 Years limited heat exchanger, 5 Years limited parts * ASME models do not utilize commercial-grade copper alloy. **Refer to for further warranty details. Installation Type Dimension ATIO-91 Temperature Settings Indoor, Outdoor, Direct Vent 25-1/4 (W) X 24-7/8 (H) X 12-1/4 (D), Weight: 112 lbs Electric 12 VAC 178 W / 1.48 A (Operation) 16 W /.13 A (Standby) 271 W / 2.26 A (Freeze-Protection) Ignition Electronic Ignition Noise Level 61 db at Max output Fuel NG LP Gas Consumption Min. Input 15, BTU/h 15, BTU/h Max. Input 38, BTU/h 38, BTU/h Thermal Efficiency 8.2% 82.4% Gas Pressure Min 5." W.C. Min 8." W.C. Max 1.5" W.C. Max 14." W.C. Flow Rate 14.5 GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition. Hot/Cold/Gas Connection 1 NPT Coil Capacity.32 Gallons Water Pressure PSI Pressure Only Relief Valve Requires (Min 38, btu/h, 15 PSI). 4 psi or above recommended for max. flow Multiple Unit Installation Easy-Link System Up to 4 units With no need for a system controller Multi-Unit System Up to 1 units With (Multiple Unit System Controller) Dipswitches 1 F 115 F 12 F (default) 135 F 145 F 155 F 165 F 185 F With remote (max. distance 4 from heater, non-polarized 2 gauge wiring) 1 F 15 F 11 F 115 F 12 F (default) 125 F 13 F 135 F 14 F 145 F 15 F Default Mode 155 F 16 F 165 F 17 F 175 F High Temp. Mode 11 F 115 F 12 F (default) 125 F 13 F 135 F 14 F 145 F 15 F 155 F 16 F 165 F 17 F 175 F 18 F 185 F 91: Flow Rate vs. Temperature Rise 91: Pressure T-M5 Pressure Loss Loss Pressure Loss (psi) Head (ft) Set temperature: 145 F or lower Set temperature: 15 F or higher Set temperature: 145 F or lower Set temperature: 15 F or higher Flow Rate (gpm) Clearance Indoor Installations Outdoor Installations Clearances to Combustible and Non-Combustible Surfaces Back.5 Back.5 3

34 EASY-LINK SYSTEM For larger applications that require multiple water heaters to work in conjunction, the 51, 51U, 54H, and 91 Series feature the Easy- Link system. This allows installers to easily manifold up to 4 units without the need for a system controller. The controls are already built into each model s internal computer. The Easy-Link system ensures proper modulation, using only the amount of energy required so that there is never any waste. Refer to each model s installation instructions for details. 31

35 MULTI- UNIT SYSTEM For even larger applications, the 51U, 54H and 91 Series models also feature the Multi-Unit system, allowing a greater number of units to manifold together. The Multi-Unit System Controller is necessary to enable the Multi-Unit system. The Multi-Unit System can control up to twenty 51Us, 54Hs, and ten 91s. UNIT COMPARISON 51 Series 51U* Series 54H* Series 91 Series** EASY-LINK (No Controller Necessary) Up to 4 units Up to 4 units Up to 4 units Up to 4 units Maximum input (BTU/h) 796, 796, 796, 1,52, MULTI-UNIT N/A Up to 2 units Up to 2 units Up to 1 units Maximum input (BTU/h) N/A 3,98, 3,98, 3,8, *51U and 54H models use 9835 controller for multi-link capabilities **With controller 32

36 APPLICATION DIAGRAMS A. O. Smith tankless water heaters can be used in a wide variety of applications. Whether used in recirculation systems, in conjunction with storage tanks or with heating applications, our commercial units are built to provide endless, continuous hot water.* *Local codes dictate proper compliance Basic Installation Subsequent units in Easy-Link or Multi-Unit Systems Single Unit H C H C Legend Pump Expansion Tank Hot Water Outlet Gas Supply Cold Water Inlet Shut Off / Isolation Valves * When manifolding State water heaters, whether in Easy-Link or Multi-Unit Systems, all water heaters are to be plumbed in parallel. Check Valve Union Pressure Relief Valve Recirculation Systems Air Vent *A Single Unit Air Separator S Air Vent Hot Water Outlet to Fixtures H C Y-Strainer Gas Supply *A. O. Smith tankless water heaters provide endless hot water when sized appropriately for your home s needs. S Air Separator Recirculation Pump *C Y-Strainer Cold water Inlet 33

37 Storage Tank (3 Tappings) *A The air vent is to be installed at the highest location of the system. The diameter of the pipe leading up the air vent is to be no smaller than the piping throughout the system. Hot Water Outlet to Fixtures Storage Tank Air Vent *A Air Separator S H C Gas Supply *B 1. The tank circulation pump is to be controlled by: Dual-set aquastat (recommended w/ timer) OR A. O. Smith Pump Control set to Storage Tank Mode (if the A. O. Smith model or controller has this function) 2. The tank circulation pump is to provide no less than 2 gpm through each activated A. O. Smith unit in the system. (Exception: no less than 4 gpm through each 91 series) *C 1. The recirculation pump is to be controlled by: Dual-set aquastat (recommended w/ timer) OR A. O. Smith Pump Control set to Recirculation Mode (if the A. O. Smith model or controller has this function) 2. The recirculation pump is to provide no less than 2 gpm and no more than 4 gpm through each activated A. O. Smith unit in the system. (Exception: between 4 gpm and 8 gpm through each 91 series) Drain Tank Circulation *B Y-Strainer Cold Water Inlet Hot Water Return (Optional) *D 1. The recirculation pump is to be controlled by: Dual-set aquastat (recommended w/ timer) OR A. O. Smith Pump Control set to Recirculation Mode (if the A. O. Smith model or controller has this function) OR Thermostat controlling the heating application 2. The recirculation pump is to provide no less than 2 gpm through each activated A. O. Smith unit in the system. (Exception: no less than 4 gpm through each 91 series model) *E The pump size and control are dependant on the requirements of the heating application. Air Vent *A Heating (Combination with domestic option) Depending on the application, the system may require a priority switch or priority control. Heating Application (Radiant, Baseboard, Hydronic Air, Etc) Pump *E Heat Exchanger S Tempered Water to House T Thermostatic Mixing Valve Recirculation Pump *D H C Gas Supply All application diagrams shown are concept drawings only. These diagrams are only to be used as basic guides. It is up to the application designer to properly design the plumbing layout and correctly size all components within an application (pumps, piping, storage tanks, water heaters, etc.). All national and local codes must be followed and will dictate proper compliance. Y-Strainer Cold water Inlet 34

TANKLESS DURABILITY Tankless Product Guide

TANKLESS DURABILITY Tankless Product Guide TANKLESS DURABILITY Tankless Product Guide Energy-efficient, plentiful, and endless supply of hot water. Compact size and wall-mounted to free up valuable floor space. SAVE ENERGY. SAVE SPACE. PAGE [ 2

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

TANKLESS WATER HEATER INSTALLATION DIAGRAMS TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water

More information

Navien Condensing 98% Tankless Water Heaters. Tankless Water Heaters. Navien Condensing. The Ultimate in Energy Efficiency with Hi-Tech Comfort

Navien Condensing 98% Tankless Water Heaters. Tankless Water Heaters. Navien Condensing. The Ultimate in Energy Efficiency with Hi-Tech Comfort Navien Condensing 98% Tankless Water Heaters The Ultimate in Energy Efficiency with Hi-Tech Comfort Navien America Inc. Navien Condensing Tankless Water Heaters Navien America is an official energy star

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters POWERED BURNER MODELS LARGE-VOLUME POWERED BURNER FEATURES The large-volume powered burner line includes the largest, most powerful A. O. Smith tanktype gas water heaters. With tank capacities up to 600

More information

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH Centauri Condensing Fire Tube Water Boiler 399 to 1000 MBH Pre-mix surface burner with up to a 7-to-1 turndown NOx levels as low a 5 ppm at full rate Operates on 4" gas pressure shown with optional gauges

More information

NAVIEN AMERICA INC. 17855 FITCH AVENUE

NAVIEN AMERICA INC. 17855 FITCH AVENUE Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:

More information

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE Hot Water Boilers and Controls Why Condensing Boilers are Different Presented Oct. 14, 2008 Long Island Chapter, ASHRAE H.W. Boilers and Controls Major types of boilers Advantages and disadvantages Resistance

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable

More information

THERM Tankless Water Heaters. Applications Manual

THERM Tankless Water Heaters. Applications Manual THERM Tankless Water Heaters Applications Manual 2 THERM Tankless Water Heater Applications Manual THERM Tankless Water Heater Applications Manual 3 Table of Contents 1 Introduction 4 2 Bosch THERM Model

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters UP TO 96% THERMAL EFFICIENCY, DIRECT-VENT FEATURES TM BTH-120 through BTH-500 The A. O. Smith Cyclone Xi family of products represents the industry s most technologically advanced commercial water heaters.

More information

Cast-Iron Performance Meeting today s commercial demands with effi ciency, strength and intelligent controls.

Cast-Iron Performance Meeting today s commercial demands with effi ciency, strength and intelligent controls. Cast-Iron Performance Meeting today s commercial demands with effi ciency, strength and intelligent controls. EFFICIENCY THAT CAN T BE COMPROMISED In a commercial market where efficiency is everything,

More information

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International Presentation Overview Water Heater Piping Strategies How to size a water heater?

More information

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................

More information

Commercial Gas Water Heater

Commercial Gas Water Heater Commercial Gas Water Heater 3-Year Limited Tank/1-Year Limited Parts Warranty* The Polaris has a high grade 444 stainless steel tank with brass connections for years of dependable, trouble-free service

More information

RECON WATER HEATER INSTALLATION FORM

RECON WATER HEATER INSTALLATION FORM RECON WATER HEATER INSTALLATION FORM Please complete ONE (1) form for each SITE and return to AERCO for warranty validation within 30 days of start-up. After completion, e-mail this form to: STARTUP@AERCO.COM.

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining

More information

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459 SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

Eternal Hybrid: Engineered For How You Live. Award Winning Technology. Now Available in Canada.

Eternal Hybrid: Engineered For How You Live. Award Winning Technology. Now Available in Canada. Eternal Hybrid: Engineered For How You Live Canadians are busy. Whether it s a home or a business, we are always looking for ways to save time and save money. Eternal Hybrid combines the best of tank and

More information

SPIDERfire: Delivers high efficiency and real savings for today s businesses

SPIDERfire: Delivers high efficiency and real savings for today s businesses Product Brochure Commercial Water Heaters SPIDERfire Series SPIDERfire: Delivers high efficiency and real savings for today s businesses Up to 97% thermal efficiency 80 and 100-gallon capacity models Patented

More information

CONDENSING TANKLESS WATER HEATERS

CONDENSING TANKLESS WATER HEATERS Ty Tipton, Tipton Company Brian Fenske, Navien America CONDENSING TANKLESS WATER HEATERS THE BASICS OF TANKLESS WATER HEATERS Tankless water heaters are available in Electric Natural gas Propane fired

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide Water Circulation Pumps & Circulators Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide Taco Catalog # 100-41 Supersedes: 08/07/15 Effective Date: 09/01/15 Printed in

More information

Better Boilers. www.ibcboiler.com

Better Boilers. www.ibcboiler.com Better Boilers FEATURING OUR IBC SUPREME SUPER COIL 316TI STAINLESS STEEL HEAT EXCHANGER. From the factory in Vancouver, our uniquely designed and engineered Super Coil VFC Heat Exchanger is the best Heat

More information

SOLID. STATE. StateWaterHeaters.com

SOLID. STATE. StateWaterHeaters.com SOLID. STATE. When it comes to building durability into a product, nobody does it like State. In fact, we've tested our water heaters in some of the most hostile environments and under the toughest conditions

More information

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler Advanced Heating & Hot Water Systems A Trailblazing Energy Star Listed Boiler that Installs like a Mid-Efficiency Boiler with the Performance of a High-Efficiency Product Ultra High Efficiency Energy Star

More information

CHAPTER 9: WATER HEATING

CHAPTER 9: WATER HEATING Chapter 9: Water Heating 145 CHAPTER 9: WATER HEATING Energy costs for water heating can be as great as the costs for heating, for an energy efficient house, in a mild climate. Estimating hot water usage

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

Commercial Boiler Systems and Controls

Commercial Boiler Systems and Controls Commercial Boiler Systems and Controls Condensing Non-condensing Hybrid Systems Steel Medium Mass Copper Instantaneous Electric Riverside R HYDRONICS An introduction to hybrid boiler systems What is a

More information

SIOUX HYBRID WATER HEATER

SIOUX HYBRID WATER HEATER SIOUX Hybrid Water Heater for the Concrete Industry SIOUX HYBRID WATER HEATER Patent Pending Maximizing the Benefits of Coil and Direct-Fired Heating Technologies Higher Discharge Temperature True High-Efficiency

More information

Domestic Hot Water Systems and Plumbing Products

Domestic Hot Water Systems and Plumbing Products Domestic Hot Systems and Plumbing Products Taco Catalog #100-117 Effective Date: 09/02/15 Supersedes: 06/22/15 Printed in USA Domestic Hot Recirculation Taco Domestic Hot Plumbing Products Since 1920 Taco

More information

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle

More information

Condensing Boiler Efficiency

Condensing Boiler Efficiency Condensing Boiler Efficiency Date: July 17, 2012 PRES E NT ED BY DO N L E O NA RDI LE O N A RD I I NC. HV AC T RAI N I N G & C ON SU LT IN G Concepts 1 The current state of evolution in boiler design 2

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

Light Duty Commercial Electric Water Heater

Light Duty Commercial Electric Water Heater Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and

More information

Endless Hot Water 24/7

Endless Hot Water 24/7 Endless Hot Water 24/7 Chromagen Continuous Flow Gas Water Heaters Live in eternal comfort with endless, efficient hot water from Eternity Get hot water on demand with an Eternity continuous flow gas water

More information

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR Water Heaters Residential gas water heaters Selection Guide To select the right State water heater for a home, you need to consider the size of the family and other factors that contribute to the Peak

More information

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage

More information

High efficiency, cast-iron gas boiler

High efficiency, cast-iron gas boiler SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home

More information

Versatility ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO. www.knightheatingboiler.com

Versatility ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO. www.knightheatingboiler.com the best mod/con Performance UP TO 96 % DOE AFUE Efficiency and Versatility Now with Floor and Wall Mount Models www.knightheatingboiler.com ::::::::::::::::::::::::::::::::::::::: a Legendary Performer

More information

STATE SUPER HIGH EFFICIENCY Up To 96% Thermal RESIDENTIAL PREMIER POWER-VENT MODELS

STATE SUPER HIGH EFFICIENCY Up To 96% Thermal RESIDENTIAL PREMIER POWER-VENT MODELS STATE SUPER HIGH EFFICIENCY Up To 96% Thermal GAS WATER HEATERS Efficiency RESIDENTIAL PREMIER POWER-VENT MODELS PREMIER POWER-VENT DV RESIDENTIAL GAS WATER HEATER The ideal choice for high-demand homes

More information

Commercial Semi-Instantaneous Water Heaters

Commercial Semi-Instantaneous Water Heaters FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory

More information

On-Demand Water Heater Installation Manual and Owner s Guide

On-Demand Water Heater Installation Manual and Owner s Guide On-Demand Water Heater Installation Manual and Owner s Guide ANSI Z21. 10.3 and CSA 4.3 model only Models T-KJr2-IN / 110 T-K4-IN / 310 WARNING If the information in these instructions is not followed

More information

Applications manual. For tankless and point-of-use water heaters

Applications manual. For tankless and point-of-use water heaters Applications manual For tankless and point-of-use water heaters 2 Bosch applications manual Bosch applications manual 3 Table of Contents 1 Introduction 4 2 Bosch Water Heating Model Certifications 4 3

More information

Tankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners

Tankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners Tankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners Your Questions Answered Common applications Benefits of performance How to select, size and install Efficient water heating

More information

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR The heat transfer innovators. THE RELIANCE COPPER FINNED TUBE HYDRONIC BOILER FEATURES Copper Fin-Tube Heat Exchanger Up to 88% Thermal

More information

Water Heaters. Condensing Storage. In my 30-plus years as a plumbing contractor,

Water Heaters. Condensing Storage. In my 30-plus years as a plumbing contractor, Condensing Storage Water Heaters These heaters are up to 96 percent efficient and typically easier to retrofit than tankless models by Jim Lunt In my 30-plus years as a plumbing contractor, I ve replaced

More information

PLBG/GAS SAFETY Information Bulletin

PLBG/GAS SAFETY Information Bulletin PLBG/GAS SAFETY Information Bulletin November 2012 P/G-08-02-PLBG/GAS [Rev 3] Page 1 of 11 SUBJECT: REQUIREMENTS FOR COMBINATION HEATING SYSTEMS: DUAL PURPOSE WATER (POTABLE) HEATER (COMBO UNIT) Safety

More information

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV MODEL EMV Emergency Safety Shower Water Heater Tepid Water For Emergency Safety Shower/Eyewash Stations Features Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon

More information

www.garrisonwaterheaters.com Electric & Gas Water Heaters

www.garrisonwaterheaters.com Electric & Gas Water Heaters www.garrisonwaterheaters.com Electric & Gas Water Heaters Hot Water: Take it for Granted with Garrison According to the U.S. Department of Energy, the average American home uses 64 gallons of hot water

More information

Steam System Best Practices Condensate System Piping

Steam System Best Practices Condensate System Piping Steam System Best Practices Condensate System Piping Summary The best method for improving steam system energy efficiency, reducing chemical costs, and reducing make-up water costs is to return the maximum

More information

Measure Guideline: Transitioning to a Tankless Water Heater

Measure Guideline: Transitioning to a Tankless Water Heater Measure Guideline: Transitioning to a Tankless Water Heater K. Brozyna and A. Rapport IBACOS, Inc. September 2012 NOTICE This report was prepared as an account of work sponsored by an agency of the United

More information

Air Conditioner Water Heater Model ACWH18

Air Conditioner Water Heater Model ACWH18 Air Conditioner Water Heater Model ACWH18 Installation Guide IMPORTANT! READ THIS FIRST! Commissioning of this unit must be done by a licensed HVAC technician. Commissioning includes making the electrical

More information

Tankless water heaters

Tankless water heaters imagine RHEEM TANKLESS WATER HEATERS never running out of hot water again Tankless water heaters Continuous hot water continuoushot water from Rheem 1-2 RTG-64 Series RTG-64DV, RTG-64X Natural or LP Gas.

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES. QUIET-ONE Environmental Products 2000 Kickspace Heater Series Models: KS 2004, KS 2006 KS 2008, KS 2010 INSTALLATION OPERATING MAINTENANCE Please read these instructions thoroughly before beginning your

More information

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled

More information

2010 Residential Water Heater Replacement Check List

2010 Residential Water Heater Replacement Check List 2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This

More information

G234X-55 Conventional Gas Boiler

G234X-55 Conventional Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

Installation & Operation Manual Models: STU150-940

Installation & Operation Manual Models: STU150-940 STU-I-O Rev B Installation & Operation Manual Models: STU150-940 IMG00044 LOW LEAD CONTENT WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions

More information

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical

More information

On-Demand Water Heater Installation Manual and Owner s Guide

On-Demand Water Heater Installation Manual and Owner s Guide On-Demand Water Heater Installation Manual and Owner s Guide ANSI Z21.10.3 and CSA 4.3 540 (T-H3) model only 240 Indoor (T-H3J-DV) 340 Indoor (T-H3S-DV) 540 Indoor (T-H3-DV) Models 240 Outdoor (T-H3J-OS)

More information

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design BRYAN FLEXIBLE WATER TUBE AB SERIES STEAM AND WATER BOILER 900,000 TO 3,000,000 BTUH FORCED DRAFT GAS, OIL OR DUAL FUEL FIRED Water Boiler AB120-W-FDGO Steam Boiler AB250-S-150-FDG Originators of the Flexible

More information

REGULATORS 175/153 Series

REGULATORS 175/153 Series 175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed

More information

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety precautions should always

More information

FYI > California Title 24

FYI > California Title 24 FYI > California Title 24 Rinnai America Corporation ("RAC") prepared the below summary of California Title 24, primarily based on the California Energy Commission s 2013 Building Energy Efficiency Standards.

More information

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, 1060. Instruction No.

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, 1060. Instruction No. Instruction No. AERCO INTERNATIONAL, Inc., Northvale, New Jersey, 07647 USA PIPING GUIDE GF-115-P Modulex Gas Fired Boiler Systems Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909,

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL MODELS: HA018240 HA024240 HA027240 HA036240 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety

More information

Dehumidification Frequently Asked Questions

Dehumidification Frequently Asked Questions Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful

More information

T-KJr. Instantaneous Water Heater Installation Manual and Owner s Guide

T-KJr. Instantaneous Water Heater Installation Manual and Owner s Guide T-KJr. Instantaneous Water Heater Installation Manual and Owner s Guide WARNING This product must be installed and serviced by a licensed plumber, a licensed gas fitter, or a professional service technician

More information

Preventing Overheated Boiler Incidents

Preventing Overheated Boiler Incidents Preventing Overheated Boiler Incidents PSE&G Appliance Service October 2012 Runaway Boiler Explosion Review Items Hazard Background Past Incidents PSE&G Emergency Response Future Process Improvements What

More information

T-K3 Instantaneous Water Heater Installation Manual and Owner s Guide

T-K3 Instantaneous Water Heater Installation Manual and Owner s Guide T-K3 Instantaneous Water Heater Installation Manual and Owner s Guide WARNING This product must be installed and serviced by a licensed plumber, a licensed gas fitter, or a professional service technician.

More information

INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS

INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS FOR MODELS EPJ-40 AND EPJ-56 SEE REAR COVER FOR INDEX Read this instruction manual before installation, operation, or service. Failure

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in

More information

Commercial Electric Water Heater

Commercial Electric Water Heater Commercial Electric Water Heater Provides Tepid Water For Emergency Fixtures Features Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust

More information

Hot Water Heating: Technologies and Use

Hot Water Heating: Technologies and Use Hot Water Heating: Technologies and Use Skip Hayden Integrated Energy Systems CanmetENERGY Better Buildings by Design 2010 Burlington Vermont February 2010 Natural Resources Canada Ressources naturelles

More information

Mega-Stor INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS

Mega-Stor INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS D E S I G N E D T O L E A D Mega-Stor TM Stainless Steel, Indirect Water Heaters INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS CAUTION 1. having a toxicity rating or Class

More information

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI). SECTION 23 52 30 PART 1 - GENERAL 1.01 RELATED WORK A. Section 23 05 00: Common Work Results for HVAC B. Section 23 25 00: Chemical Water Treatment C. Section 23 51 23: Flue Piping 1.02 QUALITY ASSURANCE

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx

More information

DESIGNER S GUIDE EFFICIENCY+ BOILER

DESIGNER S GUIDE EFFICIENCY+ BOILER DESIGNER S GUIDE EFFICIENCY+ BOILER 150,000 300,000 BTU/HR Dear Specifier/Project Manager, At Lochinvar, we have long recognized the importance of innovation to any product or service. Those who enter

More information

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED High Efficiency Condensing Boilers Proven Reliability, American-Made Home Heating Comfort. Look for this logo throughout this literature to see the unique features that set U.S. Boiler Company apart from

More information

APC APPLICATION NOTE #112

APC APPLICATION NOTE #112 #112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

Indirect Fired Water Heaters

Indirect Fired Water Heaters Indirect Fired Water Heaters Installation and Operating Manual C US Models: SST150-40 SST250-65 SST300-80 SST450-119 CAUTION The heat transfer medium must be water or other nontoxic fluid having a toxicity

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Installation & Operation Manual Models: SIT030 - SIT119

Installation & Operation Manual Models: SIT030 - SIT119 SIT-I-O Rev K Installation & Operation Manual Models: SIT030 - SIT119 CAUTION: The heat transfer medium must be water or other nontoxic fluid having a toxicity rating or class of 1, as listed in Clinical

More information

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00 RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls

More information

HL Series - Commercial Heaters Tankless Water Heating Solutions

HL Series - Commercial Heaters Tankless Water Heating Solutions HL Series - Commercial Heaters 5-18 kw (17,000-61,400 BTUs) Low flow activation options at.15 and.25 GPM (0.6 and 0.9 L-Min) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage

More information

Installation Operation Maintenance

Installation Operation Maintenance Installation Operation Maintenance 2009 Heat Transfer Products, Inc. Phoenix Evolution Water Heater Models* PHE130-55 / PHE199-55 PHE130-80 / PHE199-80 PHE130-119 / PHE199-119 *A suffix of LP denotes propane

More information

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

ELECTRIC/DIESEL FIRE PUMP CHECK LIST BUILDING NAME: DESIGNER: SCO REPRESENTATIVE: PUMP MANUF.: LOCATION: INSTALLER: DATE: OWNER NAME: INSTALLATION Certificate for flushing and hydrostatic test furnished Piping been hydrostatically tested

More information

Arapahoe County Residential Water Heater Installation and Inspection Guide

Arapahoe County Residential Water Heater Installation and Inspection Guide Arapahoe County Residential Water Heater Installation and Inspection Guide The attached handout is designed to be a general permit submittal and inspection guide covering most installation instances, however

More information

OTF Oil Fired Pool Heater

OTF Oil Fired Pool Heater OTF Oil Fired Pool Heater Installation Operation Maintenance Manual Service Policy 722010 Congratulations on the purchase of your new pool heater. In order to maintain peak performance of your pool heater

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

Bosch Commercial Water Heating Solutions. Includes the newest Bosch tankless, point-of-use and heat pump water heater products.

Bosch Commercial Water Heating Solutions. Includes the newest Bosch tankless, point-of-use and heat pump water heater products. Bosch Commercial Water Heating Solutions Includes the newest Bosch tankless, point-of-use and heat pump water heater products. About the Bosch Group The Bosch Group has been a leading global supplier of

More information

Vitodens 200, B2HA / B2HB - Product Introduction

Vitodens 200, B2HA / B2HB - Product Introduction - Product Introduction Foil 2, 10/2015 Viessmann Manufacturing Wall Mounted, Gas-Fired Condensing Boiler Foil 3, 10/2015 Viessmann Manufacturing A member of the Viessmann family of heating products Condensing

More information

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Air Conditioner Water Heater - A Product of HotSpot Energy LLC Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform

More information