Case Study 1 Code level 3
|
|
- Shavonne Powers
- 7 years ago
- Views:
Transcription
1 Case Study 1 Code level 3 Norbury Court Staffordshire Is a development of seven three bedroom houses, one two bedroom house and one three bedroom bungalow. Design Team Contractor - LHL Development Ltd Developer - LHL Development Ltd Architect - Sammonds Architectural Environmental Design Consultants - Hydrock Consultants Engineers - Sammonds Architectural
2 Key sustainability features: solar thermal water heating low flow rate sanitary ware rainwater recycling for garden environmentally benign material high levels of insulation recycling bins. passive sole design Technical Performance External fabric - timber frame with phenolic foam insulation U-value of 0.29W/m2K Roof timber frame with cut block foam insulation U-value of 0.20W/m2K Floor Concrete beam with polystyrene infill U-value 0.21W/m2K Doors and windows Double glazed, low e windows with a U value of 1.20W/m2K and doors average U-value of 2.0W/m2K Air permeability 5.63m3/@50pa for the first complete dwelling
3 Cost and Value: The build cost excluding land costs and fees was 950 per sq metre. This equated to an estimated 7,500 more per unit to meet the requirements of Code Level 3. Private sale value of these properties was estimated to be 10% higher than for an existing house in the local area. Lessons learnt: Using a good Code for Sustainable Homes assessor and working with them from the start. Not all renewable energy technologies will be appropriate for all sites Achieving Code Level 3 means extra costs Supply chains for some items required to achieve Code Level 3 and above are sometimes still in development.
4 Case study 2 Code level 5 The Old Apple Store Somerset Private housing, five units of detached and terraced houses Design Team Contractor Ecos Homes Developer Pippin Properties Environmental Design Consultancy Brookes Devlin Architect Malcolm McAll Design Consultant O2i Design Engineers John Beverage/ Ellis & Moore
5 Sustainability features Photovoltaic cells Solar thermal water heating Passive solar design Wood pellet boiler Low air-permeability Low energy lighting, Triple glazing Metering and plans for future post occupancy monitoring. Rainwater harvesting High levels of insulation Technical Performance External Fabric Thermally efficient timber cassette shell U-value 0.14W/m2K Roof Engineered I beams filled with recycled newspaper insulation with 100mm wood fibre with OSB top and bottom with an internal vapour control U-value 0.12W/m2K Floor Concrete planks with 150mm foam insulation under 50mm screed. U- value of 0.15W/m2K Doors and windows - triple glazed FSC certified U-value 1.2W/m2K and 1.1W/m2K Air Permeability Between 2.57 and 2.17m3/h@50pa
6 Cost and Value The build cost, excluding land costs and fees was 1,375 per sq metre. This higher than average build cost was attributed to the prototype nature of the development, the time and labour taken during the learning process and the additional costs for installing renewable energy and low carbon heating systems required for Code Level 5. Sale values of the properties were between 275,000 and 399,000, or 2,238-2,615 per sq metre. Sales prices in the local area for existing stock was about 2,045 per sq metre. Lessons Learnt Designing for Code Level 5 required detail knowledge and careful consideration of CSH criteria at the earliest design stage. Planning from the outset was crucial to achieving Code Level 5 objectives. An educated and dedicated construction team is essential to meeting the challenges of higher level Code development.
7 Case study 3 Code level 5 Mid Street - Surrey 2 Two bedroom flats located in South Nutfield. The first publicly funded Social housing development in the UK to achieve Code Level 5. Design Team Contractor Osborne Developer Raven Housing Trust Architect Harrington Design Engineers BEP Consulting Engineers Ltd
8 Sustainable Features Passive solar design Rainwater harvesting Environmentally friendly materials High levels of insulation low levels of air-permeability Low energy lighting Triple gazed windows MVHR Biomass pellet boiler Energy rated white goods Technical Performance External Fabric Insulated panel system with 50mm external insulation value0.14w/m2k Roof Timber roof concrete tiles with 400mm mineral wood insulation U-value 0.13W/m2K Floor 75mm insulation U-value 0.14W/m2K Doors and windows U value 0.80W/m2K. Doors U-value of 1.2W/m2K Air Permeability 4.9m3/h@50pa
9 Cost and Value Build cost excluding land costs and fees was c. 1,850 per sq metre. This was estimated to be an uplift of 20% over standard build costs. The biomass boiler presented the biggest source of problems requiring servicing every1-2 weeks. Significantly adding to maintenance costs. The sales value of the homes was estimated to be c. 2,857per sq metre, equal to or above sale values for equivalent properties in the area. Lessons learnt It was important to involve an experienced code assessor before drafting initial designs. Construction details need to be produced early in the design process. Shared heating systems can be a practical and cost effective solution. MVHR can significantly reduce energy requirements if correctly specified and installed. A good relationship and understanding with the site manager is necessary for a design to be realised. Material for text and photographs copyright of Crown The Code for Sustainable Homes (case studies)
10 Case Study 4 Code Level 3 Jarvie Close, Hunstanton A development of bedroom houses and flats built for Hastoe Housing Association Design Team Contractor E.N Suiters Ltd Architect Parsons and Whittley Ltd Code Assessor Parsons and Whittley Ltd Engineer Scott Wilson Consultant Engineers
11 Sustainable Features Ground source heat pumps Low energy light fittings Rainwater butts for garden Super insulation Passive solar design Low flow rated sanitary ware Recycling Technical Performance External Fabric- Cavity wall construction with facing brickwork, U- value 0.26W/m2k or 0.22W/m2k In areas finished with flint. Roof mineral wool insulation laid between and over ceiling joists U- value 0.13W/m2k Floor proprietary concrete beam & block with insulation & screed above -U-value 0.15W/m2K Doors & Windows Double glazed, lowemissivity windows U-value 1.8W/m2K and doors U-value of 1.20 W/m2K Air Permeability
12 Cost and Value Due to this scheme being classed as a Rural Exception Site there were specific design requirements that brought about additional costs. To achieve Code for Sustainable Homes Level 3 Ground Source Heat Pumps & Velfac glazed screens & windows for passive solar gain contributed 106,115 to the overall cost. The total cost per sq metre excluding land and landowner s contribution to services was 1, Lessons leant Early consideration of Code issues enabled the design to be delivered that accommodated all of the Code requirements with relative ease. An experienced contractor with a good understanding and previous experience of Code requirements further enabled easy delivery of a level 3 scheme. Using a Code Assessor and working with them from the start helped to iron out problems during construction.
13 Case Study 5 Code Level 4 Holt Road & Swans Close Norfolk A mixed development of 7, 2-3 bedroom houses and flats developed for Hastoe Housing Association. The development was planned to Code Level 4 even before it was mandatory for housing associations to achieve this. Design Team Contractor - E.N.Suiters Ltd Architect Parsons & Whittley Ltd Code Assessors - Parsons & Whittley Ltd Engineer Scott Wilson Consultant Engineers
14 Sustainable Features Ground source heat pump Passive solar design Low flow sanitary ware Rainwater recycling for garden Low energy lighting Internal recycling bins Positive enhancement of the site ecology Technical Performance External Fabric Timber Frame with Facing Brickwork. Cavity fully insulated U-value 0.25W/m2K Roof Timber Frame with mineral wool insulation laid between & over ceiling joists U-value 0.11W/m2K Floor Proprietary Concrete Beam & Block with insulation & screed above. U value 0.16W/m2K Doors & Windows Double glazed, lowemissivity windows U-value of 1.8W/m2K and doors with a U-value of 1.20 W/m2K Air Permeability at 5.16m3/@50pa
15 Cost and Value Additional costs were incurred in three specific areas: Landowner & Local Authority design requirements Features to achieve Code for Sustainable Homes Level 4 (absence of gas) Specific rural scheme requirements The total cost per sq metre excluding land and landowner s contribution to services was 1, Lessons Learnt As the first Code scheme for the design team, and the main contractor, some steep learning curves had to be accommodated. Ensuring sub- contractors understood the requirements for Code Level 4 proved difficult especially when most were set in their ways. Significant problems were encountered in obtaining responsibly sourced materials due to lack of interest from the supply chain to make it a high priority. Surface water disposal proposals had to be continually re-examined to achieve compliance.
Case Studies of Successful Code for Sustainable Homes Projects
Case Studies of Successful Code for Sustainable Homes Projects Sustainable Homes publish the Sustainable Homes Index For Tomorrow (SHIFT) and are a leading trainers of Code for Sustainable Homes assessors.
More informationTHE CODE FOR SUSTAINABLE HOMES. Case studies
THE CODE FOR SUSTAINABLE HOMES Case studies 02 CODE FOR SUSTAINABLE HOMES BACKGROUND BACKGROUND The Code for Sustainable Homes (the Code) was introduced in England in April 2007 as a voluntary national
More informationEnergy Company Obligation (ECO): Technical Monitoring Questions
Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified
More informationLow Carbon Domestic Refurbishment
www.breeam.com Briefing Paper Low Carbon Domestic Refurbishment Kiruthiga Balson, Gavin Summerson and Steven Stenlund 2 BRE Global Ltd 2014 Permission is granted for this report to be distributed only
More informationmain heating: pre1998 ducted warm air system main heating fuel: mains gas main heating SAP efficiency: 70.0% main heating controls: programmer
Archetype: 3250330 Archetype Description: 1965-1975, semi / end terraced dwelling, timber frame walls, oil / gas / electric warm air heating, E This archetype represents 823 dwellings, which accounts for
More informationGUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.
GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. This leaflet provides guidance on how to attain compliance with The Building (Amendment) Regulations (Northern Ireland) 2006, Part
More informationCode for Sustainable Homes Guidelines
Canoldir Penrhos Anglesey LL65 2TS Phone: 01407 860666 Email: saps@easonline.co.uk www.easonline.co.uk Code for Sustainable Homes Guidelines A CSH rating is the responsibility of the Developer/ Architect
More informationHANLO The WELCOME HOME Experience.!! Simply better homes!!
HANLO The WELCOME HOME Experience!! Simply better homes!! The Mission Our mission is to provide individual, sustainable and affordable homes to self builders and developers that can be built fast, efficient
More informationBER Assessors Dwellings Technical Bulletin
BER Assessors Dwellings Technical Bulletin Issue No. 2/12 April 2012 Contents: 1. SUPPLEMENTARY ELECTRIC WATER HEATING IN SUMMER... 2 2. PITCHED ROOF U-VALUE CALCULATIONS... 8 2.1. PITCHED ROOF, INSULATED
More informationProposal to achieve Code for Sustainable Homes Level 3 for a development of 7 detached dwellings
Duchy Homes Site: Cantley Lane Doncaster Proposal to achieve Code for Sustainable Homes Level 3 for a development of 7 detached dwellings 22 nd February 2013 Leanne Brooksbank Accredited Energy & Code
More informationSIP (STRUCTURAL INSULATED PANEL)
SIP (STRUCTURAL INSULATED PANEL) KINGSPAN TEK ACORN SIP ABSTRACT BUILDING SERVICES Ltd Kingspan TEK is the manufacturer and supplier of the panels and components. Acorn SIP are the Architects who individually
More informationRockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
More informationAchieving Code Level Five with Concrete and Masonry
Achieving Code Level Five with Concrete and Masonry A mainstream approach for high performance, low-cost social housing. Achieving Code Level Five with Concrete and Masonry Since the introduction of the
More informationTimber Frame Walls Rethinking Construction
Insulation Fifth Issue November 2007 Timber Frame Walls Rethinking Construction INSULATION BEST PRACTICE FOR THE 21ST CENTURY Summary 9 mm OSB sheathing 3 mm skim coated 15 mm plasterboard Rock or glass
More informationRainwater Harvesting
Rainwater Harvesting With climate change now a reality rather than a speculated possibility, the demand on water resources has gone up, whilst the amount of water available for supply has gone down. Forth
More informationFABRIC ENERGY EFFICIENCY FOR PART L 2013
Informing the Part L 2013 consultation FABRIC ENERGY EFFICIENCY FOR PART L 2013 WORKED EXAMPLES AND FABRIC SPECIFICATIONS February 2012 Introduction This report has been produced by the Zero Carbon Hub
More informationD 4.4 Activity Report Technical support during the planning phase of new buildings
Grant agreement no. IEE/11/981/SI2.615956 MLEI BEAM-Graz City of Graz (AT) Boosting Energy Efficiency Actions in the Municipal Buildings of the City of Graz D 4.4 Activity Report Technical support during
More informationContents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37
Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details
More informationMaximising the economic benefits of sustainable energy in Dorset
Maximising the economic benefits of sustainable energy in Dorset 24 October 2012 Write up of discussion workshops and business feedback Introduction This paper includes a write up of the roundtable discussions
More informationDelivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015
www.zebra2020.eu Delivering on innovation and market uptake. Best-in-cases of nzeb Ramon Pascual Bucharest May 8th, 2015 Outline nzeb Database Best in cases of nzeb Climates in Europe Preliminary results
More informationPost-insulation of cellar ceiling and cellar walls
WP5 Education and Economic Promotion Post-insulation of cellar ceiling and cellar walls Educational product: New lecture material for training modules dealing with knowledge and skills how to apply suitable
More informationReport Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669
Report Date: 04/03/2014 Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669 About this Advisory Report Energy use in our homes is responsible for almost
More informationModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape
ModuSec Secure and efficient IT room solutions Turnkey Modular Construction Fast clean build to any size or shape Room in room Standalone external build Transportable Modusec SR Options Modusec SR Options
More informationSection 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
More informationGarden Bothy, Cumnock
Refurbishment Case Study 8 DRAFT Garden Bothy, Cumnock Upgrades to walls, floors, windows & door The views expressed in commissioned case studies are those of the authors and do not necessarily represent
More information1..GENERAL DATA 2. CLIMATIC DATA. Location
1..GENERAL DATA Location Szentendre, Downtown, Hungary Property Community centre of Szentendre, Public, Municipality of Szentendre Year of Building: End of 19th Century Present use (1) Community centre
More informationBuilding Control Guidance Note
Elements Renovation / Replacement. Issued 25/01/13 Rev a Page 1 of 9 (Applies to both Domestic and Non-Domestic Premises) Works relating to thermal elements can arise in building an extension, a material
More informationEnergy Performance Certificate
Energy Performance Certificate 14, Clifton Road, Anfield, LIVERPOOL, L6 4BQ Dwelling type: Groundfloor flat Date of assessment: 27 January 2009 Date of certificate: 27 January 2009 Reference number: 21389078626951619080
More informationEnergy Performance Certificate
Energy Performance Certificate Flat 3 Dwelling type: Mid-floor flat 30, Brunswick Square Date of assessment: 23 September 2008 HOVE Date of certificate: 23 September 2008 BN3 1ED Reference number: 8398-6021-5510-4127-8022
More informationSchool in Schwanenstadt, Austria
School in Schwanenstadt, Austria 1. INTRODUCTION PROJECT SUMMARY - building period 1960s - numerous expansions SPECIAL FEATURES - Renovation to meet Passive House Standard - decentralized ventilation system
More informationBER Assessors Dwellings Technical Bulletin
BER Assessors Dwellings Technical Bulletin Issue No. 3/11 May 2011 Contents: 1 Window defaults in DEAP and use of DEAP Table 6a... 2 2 Solar Space Heating Systems in DEAP... 4 3 Storage and direct electric
More information(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)
Energy Performance Certificate Georgia House Stud Bradley Road Burrough Green NEWMARKET CB8 9NH Dwelling type: Detached house Date of assessment: 17 August 2011 Date of certificate: 17 August 2011 Reference
More informationSCHEDULE OF FINISHES AMBLE RIDGE RETIREMENT VILLAGE
SCHEDULE OF FINISHES AMBLE RIDGE RETIREMENT VILLAGE SITEWORKS FOUNDATIONS & SURFACE BED Site to be cleared and leveled. Builder s rubble to be carted away. As per Engineer s design, with USB green waterproofing.
More informationModule 3.7. Thermal bridging
Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal
More informationFACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS
FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS 1 Ralf Lindberg, Professor Minna Korpi, M.Sc. Juha Vinha, Dr.Tech. June 11, 2008 Department of Civil Engineering, Tampere University of Technology 2 BACKGROUND
More informationCase Study: Wood Gasification Boiler Heating for an Exposed Rural Family Home Fuel cost assessment following thirty six months of operation
Case Study: Wood Gasification Boiler Heating for an Exposed Rural Family Home Fuel cost assessment following thirty six months of operation Simple solutions for greener heating Summary Objective: Deliver
More informationCity Council Report for Information
City Council Report for Information Report to: Subject: Report of: Neighbourhood Scrutiny Committee Sustainable Development Assistant Chief Executive (Regeneration) Summary This report outlines measures
More informationRosslare Case Study Passive House Cost Analysis. Seamus Mullins Quantity Surveyor Michael Bennett Group
Rosslare Case Study Passive House Cost Analysis Seamus Mullins Quantity Surveyor Michael Bennett Group 2 South Elevation North Elevation 3 West Elevation East Elevation 4 Ground Floor Plan 5 First Floor
More informationGuide to Planning Permission and Building Regulations for Householders Please note that this is an informal guide to planning permission and building regulations for householders. Questions regarding specific
More informationPRESTRESSED CONCRETE FLOORING BEAMS
PRESTRESSED CONCRETE FLOORING BEAMS TRIED & TRUSTED Introduction Established in 2001 TT Concrete Products Limited has become a prominent manufacturer of prestressed concrete flooring beams throughout the
More informationCASH SAVING BEATS ECO CONCERNS AS MAIN REASON TO GREEN YOUR HOME
Press Release CASH SAVING BEATS ECO CONCERNS AS MAIN REASON TO GREEN YOUR HOME Saving money is now our main motivation for carrying out green home improvements ahead of concerns for the environment. One
More informationRev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org
Rev 1-12.2013 Code of Practice SIP Technology www.uksips.org What are Structural Insulated Panels (SIPS)? SIPS are prefabricated, high performance, lightweight, building panels that can be used in floors,
More informationBuilding Control Guidance Note
Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you
More informationWe care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview
http://upload.wikimedia.org/wikipedia/commons/a/ae/flag_of_the_united_kingdom.svg.0.0 :8 Seite von Environmentally-Friendly Building Products from Renewable Resources Product range overview We care about
More informationEnergy Efficient Windows
Energy Efficient Windows All properties lose heat through their windows. But energy-efficient glazing keeps your home warmer and quieter as well as reducing your energy bills. That might mean double or
More informationONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION
The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 E1 E2 E3 E4 E Protection against sound from other parts of the building and adjoining buildings Protection against
More informationFire 2This Technical Bulletin has been commissioned by the UK SIP Association in
REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory
More informationImplementation of the EPBD in Cyprus. Status in November 2010. 1 > Introduction. 2 > Certification. Cyprus
Implementation of the EPBD in Cyprus Status in November 2010 Constantinos Xichilos Energy Service Ministry of Commerce, Industry and Tourism Nicos Hadjinicolaou Energy Service Ministry of Commerce, Industry
More informationTechnical housing standards nationally described space standard
Technical housing standards nationally described space standard March 2015 Department for Communities and Local Government Crown copyright, 2015 Copyright in the typographical arrangement rests with the
More informationTwinning «Improvement of the Energy Efficiency in Turkey»
Twinning «Improvement of the Energy Efficiency in Turkey» SECTOR BUILDING WORKSHOP Thermal Rehabilitation of Existing Buildings and Energy Building Code Residential energy efficiency overview in Ankara:
More informationGuide to Improving Your Home
Guide to Improving Your Home WELCOME Contents Where to start 03 Improvement ideas 04 Outside 04 Kitchen 05 Living space 05 Bathroom 06 Bedrooms 06 Get more space 07 Add an extension 07 Convert a garage
More informationWelcome to a warmer home. You could qualify for: www.ieservices.org.uk. Your guide to a gas supply and central heating system
Welcome to a warmer home Your guide to a gas supply and central heating system You could qualify for: Up to 2,404 towards the cost of connecting gas to your home Up to 1,300 towards new gas central heating
More informationEnergy Performance Certificate
Energy Performance Certificate 0 Raleigh Drive CULLOMPTON EX15 1FZ Dwelling type: Date of assessment: Date of certificate: Reference number: Type of assessment: Total floor area: Semi detached house 09
More informationENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ
ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ Ref. No: 12/02870/FULM Contents 1. General... 2 2. Planning Condition... 2 3. Development...
More informationNorwegian Tax Authority - Oslo Norway
1. INTRODUCTION Norwegian Tax Authority - Oslo Norway PROJECT SUMMARY Year of construction - 1980 No previous energy renovations SPECIAL FEATURES Main topics in the renovation are: High insulated pre fabricated
More informationEcojoist. Practical benefits of Ecojoist. www.eleco.com/gang-nail
Ecojoist Practical benefits of Ecojoist. www.eleco.com/gang-nail Gang-Nail Systems, an Eleco plc company, offer integrated solutions f the timber engineering industry which assist in reducing design, production
More informationSection 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01
Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal
More informationNordicWood. Scandinavian Timber Frame Buildings
NordicWood Scandinavian Timber Frame Buildings Welcome to NORDIC WOOD - the Scandinavian timber frame specialist A traditional or contemporary timber frame building from Nordic Wood will not only add an
More informationA Guide to... Home Renovation Incentive (HRI)
A Guide to... Home Renovation Incentive (HRI) About this guide This guide will tell you what you need to know if you are organising to have construction work done on your house and would like to avail
More informationBUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010
Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance
More informationKilleen Castle Gate Lodge Killeen Castle, Dunsany, Co Meath. For Sale by Private Treaty
Killeen Castle Gate Lodge Killeen Castle, Dunsany, Co Meath For Sale by Private Treaty KILLEEN CASTLE GATE LODGE Killeen Castle Gate Lodge is a spectacular detached three bedroom Lodge extending to 2,045sq.ft./190sq.m.
More informationPassive & Active Design
Passive & Active Design CIBSE Building Simulations Group Peter A. Brown CEng, MBA October 2010 Introduction Passive & Active Design Introduction What are the interactions between passive and active design?
More informationBuild Back Smarter: House performance improvements at the time of earthquake repairs
Build Back Smarter: House performance improvements at the time of earthquake repairs Lois Easton Beacon Pathway Inc Project aims To show that home performance improvements can and should be included in
More informationExtra Low Energy Housing in Ireland How far should we go to the Passive House? Jonathan Jennings Head of R&D Kingspan Century Homes
Extra Low Energy Housing in Ireland How far should we go to the Passive House? Jonathan Jennings Head of R&D Kingspan Century Homes Current Status % CO 2 emissions Transport 30% Agriculture 2% Housing
More informationAssessment Methods. 15 th November 2010 Huw Jenkins Simon Lannon
Assessment Methods 15 th November 2010 Huw Jenkins Simon Lannon Assessment Methods Program Country Year Program Country Year 1 R-2000 Canada 1982 12 LEED US 2000 2 P-mark Sweden 1989 13 ECO-Quantum Netherlands
More informationGreen and Sustainable Buildings
Green and Sustainable Buildings Design Criteria and Application in Hong Kong Green building is the practice of increasing the efficiency with which buildings use resources energy, water and materials.
More informationSection 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with
Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and
More informationPERMISSION A GUIDE FOR EXTENDING A DETACHED OR SEMI-DETACHED HOUSE
PLANNING PERMISSION A GUIDE FOR EXTENDING A DETACHED OR SEMI-DETACHED HOUSE Introduction Foreword by Councilor Dave Smith - Chair of the Planning & Highways Committee. Planning Permissions B Owners of
More informationModular Accommodation Solutions. Flexibility, efficiency and quality in one complete package
Modular Accommodation Solutions Flexibility, efficiency and quality in one complete package Welcome Our Services Providing Your Solutions The clients who work with SEDAC Accommodation Solutions are extremely
More information14 October 2013. Home Ownership Services Islington Council Highbury House 4-5 Highbury Crescent London N5 1RN
14 October 2013 Leaseholder Islington Home Ownership Services 4-5 Highbury Crescent T 020 7527 7715 E homeownership@islington.gov.uk W www.islington.gov.uk Property reference: 000000 / ZZ Dear Leaseholder
More informationMulti-layer Insulation Blanket for Roofs
Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof
More informationAchieving Net Zero. Bradley Berneche, President Alouette Homes. National Marketing Committee Canadian Home Builders Association Ottawa, June 6, 2008
Achieving Net Zero Bradley Berneche, President Alouette Homes National Marketing Committee Canadian Home Builders Association Ottawa, June 6, 2008 Overview Who Is Alouette Homes? The EQuilibrium Initiative
More informationAdvantages and Disadvantages of Timber Frame Construction
Appendix 1: Table A1.1 Advantages and Disadvantages of Timber Frame Construction Advantages of Timber Frame Construction Quick erection times Reduced site labour Reduced time to weather the structure Earlier
More informationIES <Virtual Environment> Tutorial. Apache Sim (Version 6.0)
IES Tutorial Apache Sim (Version 6.0) Introduction This tutorial will begin by showing you how to use the Building Template Manager (BTM) to create thermal and construction data for
More informationCapital Expenditure. The common definition of capital expenditure is
Capital Expenditure Under standard accounting practices local authorities are required to account for revenue expenditure and capital expenditure differently. Capital expenditure is defined in the Local
More informationtap into opportunities to develop your business
Find out more about the Green Deal, ECO and renewable energy markets and how your business can benefit tap into opportunities to develop your business Background and overview Over recent years, the UK
More informationBFRC ENERGY RATING THE REHAU ABC ENERGY EFFICIENT WINDOWS AND DOORS. www.rehau.co.uk. Building Solutions Automotive Industry
BFRC ENERGY RATING THE REHAU ABC ENERGY EFFICIENT WINDOWS AND DOORS www.rehau.co.uk Building Solutions Automotive Industry INTRODUCTION IMPROVING THE ENERGY EFFICIENCY OF WINDOWS AND DOORS This information
More informationData Collection Summary Report
Data Collection Summary Report Asilo Cologno Monzese Polo Territoriale per la Prima Infanzia con Asilo Nido 22/09/2011 The sole responsibility for the content of this report lies with the authors. It does
More informationIEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards
Date of revision: 15.6.2012 Osram Culture Centre Copenhagen, Denmark Valhalsgade 4, 2200 Copenhagen N 1. INTRODUCTION PROJECT SUMMARY Construction year: 1953 Energy renovation: 2009 No past energy renovations
More informationGREEN EFFICIENT FRIENDLY SUSTAINABLE ENERGY: CERTIFICATED TRAINING
GREEN EFFICIENT FRIENDLY SUSTAINABLE ENERGY: CERTIFICATED TRAINING Petroc is putting its energy into renewables and sustainable technologies. Are you? Petroc has developed Environmental Technologies CoVE
More informationTechPractices: Home Front Homes:
TechPractices: Home Front Homes: PATH's Technologies in Practice are large scale housing projects throughout the U.S. where innovative technologies are being installed and used. Information is presented
More informationGreen Architecture and Construction
Green Architecture and Construction Prof. Dr. Soontorn Boonyatikarn Center of Excellence Building and Environmental Technology, Department of Architecture, School of Architecture, Chulalongkorn University,
More informationtechnology UICK progressive sustainable any design, any shape, any colour, anywhere you like!
uality using advanced building technology UICK uality innovative progressive sustainable any design, any shape, any colour, anywhere you like! 2 NicheQ is an award winning progressive and innovative builder
More informationCONSERVATION AREAS. Residential Planning Guidelines DO I NEED PLANNING PERMISSION? Examples of Development that require Planning Permission
CONSERVATION AREAS Residential Planning Guidelines DO I NEED PLANNING PERMISSION? Examples of Development that require Planning Permission Windturbines will usually require planning permission Extensions
More informationCONSTRUCTION COST GUIDE
KEEPING YOUR COSTS TO A MINIMUM CONSTRUCTION COST GUIDE SECOND HALF 2012 One Lower Leeson Street, Dublin 2, Ireland Telephone 01 685 7219 Email info@build.ie Website www.build.ie SCSI TENDER INDICES Building
More informationConservatory warm roof conversion system
Conservatory warm roof conversion system IS YOUR EXISTING CONSERVATORY ROOF: Too hot in summer or too cold in winter? Waste of valuable living space? Unable to relax to watch TV? Transform your conservatory
More informationBYG DTU. Thermal properties of window frame Type 1 Sheet: 1. Type: Side, top and bottom profile. Source file: Format: dwg/dxf bmp
Thermal properties of window frame Type 1 Sheet: 1 Type: Side, top and bottom profile Profile: Frame profile made of wood and a GRP profile mounted with a sealed triple glazing unit. Materials: Wood GRP
More informationresearch highlight Highly Energy Efficient Building Envelope Retrofits for Houses
research highlight June 2012 Technical Series 12-103 Highly Energy Efficient Building Envelope Retrofits for Houses introduction In Canada approximately 30% of all energy is consumed in buildings, with
More informationFall in love with your heating again. Reduce your heating bills with
Fall in love with your heating again Reduce your heating bills with Worried about your energy bills? We re here to help! With energy prices rising and great pressure on household budgets, it s sensible
More informationSection 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining
Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02
More informationEnergy Performance Certificate
Energy Performance Certificate Flat 2 Bagshot House Redhill Street LONDON NW1 4BY Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Ground-floor flat 09 April
More informationValuation Report. Property Address: Bristol. Date Inspected: 14 August 2013 CHARTERED SURVEYORS AUCTIONEERS VALUERS ESTATE AGENTS
Valuation Report Property Address: Bristol Prepared for: Mr & Mrs Date Inspected: 14 August 2013 CHARTERED SURVEYORS AUCTIONEERS VALUERS ESTATE AGENTS CONTENTS Part 1 Part 2 Part 3 Part 4 Instructions
More informationMODERN HOME EXTENSIONS
MODERN HOME EXTENSIONS EASY D-I-Y-FLAT PACK KITS OR A COMPLETE INSTALLATION Timber Engineering Europe and Timber Kit Solutions have designed a range of exclusive high end home extensions and garden rooms
More information- 1 - Element Type. 9 mm gypsum board, 50 mm mineral wool (glued) 9 mm gypsum board, 50 mm mineral wool (on wooden studs, at 300 mm centres)
concrete 160 mm concrete 180 mm concrete 200 mm concrete 220 mm concrete 230 mm concrete 240 mm concrete 260 mm calcium silicate block 214 mm calcium silicate block 240 mm calcium silicate block 265 mm
More informationBuilding Warrant Issues
Building Warrant Issues Frequently Asked Questions Introduction This section is intended to help anyone who is unfamiliar with the building standards system in Scotland. The information contained in it
More informationSaint Cloud Business Center
Saint Cloud Business Center 14 7th Avenue North Saint Cloud, MN 56303 For Sale Located on 7th Avenue in the heart of downtown across from the Court House Square. A large professional reception area with
More informationGreen House, Hungary
Further information Skanska AB www.skanska.com Contact Noel Morrin, SVP Sustainability & Green Support noel.morrin@skanska.se Green House, Hungary Case Study 109 Aspects of Sustainability This project
More informationRainwater Harvesting Systems Cernunnos Homes Version 1.0
Rainwater Harvesting Systems Cernunnos Homes Version 1.0 On average a UK citizen consumes around 150 litres of mains water per day. Installing water saving devices such as aerated taps; shower heads; and
More informationBuilding Regulations for the Conservation of Fuel and Power
Insulation CI/SfB Rn7 M2 First Issue April 2014 Building Regulations for the Conservation of Fuel and Power ENGLAND EXISTING DWELLINGS 2013 EDITION Low Energy Low Carbon Buildings Contents Page Introduction
More informationRockwool Cladding Roll
Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F
More information