1 RELAYS

2 YOUR AUTOMATION SOLUTIONS PROVIDER PROXIMITY SENSORS CORDSETS I/O SOLUTIONS MEASUREMENT RFID TURCK s global support network consists of over,00 employees in countries and 0 exclusive agencies worldwide that strive to meet customer expectations. Our sales, support and manufacturing facilities are strategically located across the world allowing us to respond to local market conditions and deliver customer specific solutions on a timely basis. We are a world leader in automation technology with a diverse and broad product portfolio that provides customer specific applications with high performance, reliable and cost effective solutions. The synergy in our product portfolio and customization flexibility are key components of our value proposition. INTERFACE MODULES CUSTOM CONNECTIVITY Our expertise spans across two major industry categories: Industrial Automation and Process Automation. Each weighs in with its own unique requirements and methods of conducting business. This market centric approach ensures that we develop application specific solutions across a variety of vertical market segments. POSITION NETWORK MEDIA B Fax: () -00 TURCK Inc. Minneapolis, MN

3 RELECO by TURCK RELAYS Introduction Relays Sockets Timers RINT Fax: () -00 TURCK Inc. Minneapolis, MN B0

4 Application Types Poles AC Ratings DC Ratings Page Sockets Page General Purpose C-0 Universal -Pin, Standard 0 0 V 0. 0 V S - C-A0 Universal -Pin, Standard 0 0 V 0. 0 V 9 S -9 C-A0 Square Base, -Pole 0 0 V 0. 0 V S 0- C-0 Square Base, AC Power 00 V 0. 0 V S - C-A0 Square Base, AC Power 00 V 0. 0 V S - C-A0 Miniature, AC Power 0 V 0. 0 V S - C-0 Miniature, AC Power 0 0 V 0. 0 V 9 S - C-0E Miniature, AC Power 0 0 V 0. 0 V 0 S - C9-A Miniature, -Pin Plug-in 0 V 0. 0 V S9 - C0-A0 Interface Standard 0 0 V 0. 0 V S0-0 C0-A0E Interface Standard 0 0 V 0. 0 V S0-0 C- Interface Standard 0 V 0. 0 V S 0- Bifurcated Contacts Low Level Loads C-T Universal -Pin Plug-in 0 V 0 V S - C-T Universal -Pin Plug-in 0 V 0 V 0 S -9 C-T Miniature 0 V 0 V S - C0-T Interface Twin 0 V 0 V S0-0 C0-GT Interface Twin N.O. 0 V 0 V S0-0 Bifurcated Contacts Current Level Loads C-H Miniature 0 0 V 0 V S - Open Contacts DC Load Switching Flag Not Available C-G0 Universal -Pin Plug-in 0 0 V. 0 V S - C-G0 Universal -Pin Plug-in 0 0 V. 0 V S -9 C-G0 Square Base 00 V. 0 V S - C-G0 Miniature 0 0 V 0. 0 V S - C0-G0 Interface N.O. 0 0 V 0. 0 V S0-0 Flag Available C-G Interface N.O. 0 V 0. 0 V S 0- Double Make DC Load Switching C-X0 -Pin, DC Power 0 0 V 0 V S -9 C-X0 Square Base, DC Power 0 0 V 0 V 9 S 0- C-X0 Square Base, DC Power 00 V 0 V S - Flag Not Available C-X0 Miniature, DC Power 0 0 V 0 V S - B Fax: () -00 TURCK Inc. Minneapolis, MN

5 Application Types Poles AC Ratings DC Ratings Page Sockets Page Latching C-R0 -Pin Plug-in 0 0 V 0. 0 V S -9 C-R0 Square Base, -Pin 0 0 V 0. 0 V 0 S 0- C-R0 Square Base 0 00 V 0. 0 V S - LED Not Available C9-R Miniature 0 V 0. 0 V 9 S9 - Magnet Blow-out C-M0 -Pin Plug-in, High DC Load 0 0 V 0 0 V S -9 C-M0 Square Base, High DC Load 00 V 0 0 V S - C-M0 Square Base, High DC Load 0 V 0 V S - Sensitive 00 mw - 00 mw C-E Universal -Pin Plug-in 0 V 0 V S -9 C-N Universal -Pin Plug-in 0 V 0 V S -9 Flag Not Available C9-E Miniature 0 V 0 V 0 S9 - Lamp Switching C-W0 Miniature, FASTON 0 0 V 0. 0 V S - Railway Applications R-N0D Universal -Pin Plug-in 0 V 0 V S -9 R-0D Miniature 0 0 V 0 0 V S - R-TD Miniature, Twin Contacts 0 V 0 V S - Solid State Relay CSS-AC Instantaneuos 0 V N/A 0 S0-0 CSS-AZ Zero-cross 0 V N/A S0-0 CSS-DCN Common Negative N/A 0 V 9 S0-0 CSS-DCP Common Positive N/A 0 V S0-0 Time Cube CT -Pin Plug-in Timer Module 0 0 V 0. 0 V - S - CT -Pin Plug-in Timer Module 0 0 V 0. 0 V - S -9 Interface Module RINT Interface Module N/A 0 V V Fax: () -00 TURCK Inc. Minneapolis, MN B0

6 Five Colors for Easy Identification of Coil Voltage System Features & Benefits Coil voltage marked on top of the relay Label Button and lockable level with functions Mechanical and LED indication as standard AC DC Red: 0 VAC Maroon: AC other than 0 V Grey: VAC/DC Dark Blue: DC other than V Blue: VDC Optional built-in suppressor Part number and technical information marked on the side of the relay Color coded test button Industrial terminals FASTON.09 (. mm) If you do not want the lockable function, you can use the orange dead-man-push-button. S0-OP for MRC and S9-OP for QRC ( piece bag). Dead-man-push-button A black blanking plug is available if you don't want a test button. S0-NP for MRC and S9-NP for QRC ( piece bag). Push-to-Test-Pull-to-Lock button (PTPL) Coil voltage marked on the top face of the relay Label Double window for the mechanical identification LED Blanking Plug LED Comprehensive Technical Label Coil Power Wiring diagram with sequential and DIN numbers Electrical diagram showing all additions to the coil Maximum switching capacity according to EN 09 (IEC 9) Label Approvals Country Approval Country Approval Canada China Authority: CSA Specifi cation: C.; UL 0 Authority: CQC Specification: GB0.-00 United Kingdom Authority: Lloyd s Register of Shipping Russia Authority: KORPORATSIA STANDARD Specification: GOST R USA Authority: UL Specification: C.; UL 0 B Fax: () -00 TURCK Inc. Minneapolis, MN

7 Industrial Relays MRC, QRC, IRC Part Number Key Part Number Keys are to assist in IDENTIFICATION ONLY. Consult factory for catalog items not identified. C n(n) - T S y zz /...V Ref. nnnn Normal Industrial Relay code Relays with code R are used for railway series. Basic type refers to the product line Numbers between and are used. Relay Type A = Standard (general-purpose) contact E = Sensitive drive with 00 mw coil power G = Refers to a NO contact H = Single-point contact + twin contact load to signal current circuit for switching state feed back. Mixed contact configuration M = Relay with highly effective neodimium blow magnet for fast quenching of the arc. This relay is particularly suitable for high DC loads. N = Sensitive drive 00mW coil power R = Code for remanence relays, drive-specific ID S = Sensitive drive with 0 mw exciter input T = Twin contact for signal and control circuit W = With tungsten contact for maximum switch-on currents Number of Contacts Options Ref. nnn Relays with a reference number are versions with special (e.g. customised) features. These features may relate to special test criteria, tolerances or other properties. Availability of such relays may be limited to certain customers or applications. Nominal coil voltage or current AC V, DC V, UC V (AC/DC), AC A, DC A Relays are generally available for voltages of V. DC 0 V/AC 0 V (AC 00 V) or UC. V. Current relays available on request. D = Integrated freewheeling diode F = Integrated freewheeling diode and series diode e.g. for common alarm circuits R = RC connection for the coil X = Electric position indicating device with LED B = Bridge rectifier Definition of Contact Material This code may differ depending on type. Examples: 0 = in the standard range stands for AgNi -9 = see contact material for each type Product range Releco offers a wide range of relay types and versions and associated bases and accessories. Standard (general-purpose) relay, MRC series x mm round plug-in relay, - or - terminals multipole connector according to IEC with or contacts up to 0 A and different contact types and contact materials. Standard relay x mm with flat blade connectors with up to contacts and up to A with contacts. Miniature industrial relay, QRC series. mm series with up to contacts and up to 0 A with or contacts Interface relay, IRC series Overall width mm with up to electromechanical contacts, or fully electronic switches. Special relays, remanence relays While "normal" relays are monostable, i.e. they return to the idle state when the excitation is switched off, remanence relays are bistable, i.e. the current switching state is retained irrespective of the excitation. Relays of this type are available in different versions. Electronic relay, CSS In the IRC series different electronic DC or AC relays up to A are available. For AC relays a distinction is made between synchronously (zero crossing) and asynchronously switching versions. For switching transformer loads we recommended using asynchronously switching semiconductor switches. For incandescent lamp loads etc. synchronously switching switches are ideal for avoiding high switch-on currents. Accessories Suitable bases are available for the different relay series for DIN rail mounting or panel mounting. In addition, retaining clips are available for the relays, some of which are included in the scope of supply. Suitable bridges for cost-saving wiring in series are also available Fax: () -00 TURCK Inc. Minneapolis, MN B0

8 General Information Contact Materials Silver-nickel (AgNi) and silver-tin oxide (AgSnO ) are used as standard contact materials for all models. Other contact materials are available on request. Gold Flash For relays that are intended to be stored or remain unoperated for any length of time, a 0.µ layer of gold protects the contacts from oxidization. Gold Plating A 0µ plate of gold increases the operational reliability. It should be used for switching low level currents. Contact Resistance Contact resistance is dependent on contact material, contact pressure and cont act contamination. High contact resistance raises the temperature of the contacts, therefore reducing their working life. Typical contact resistance of the MR-C and QR-C relays is 0 mω. Contacts Gap Contact gap and opening speed of the contacts have an influence on the length and the duration of the arc. In the case of AC, a gap of 0. mm is sufficient to quench the arc which occurs automatically at the zero point of the cycle. In the case of DC, the arc only quenches when the contact gap is sufficient for the voltage and current applied. Please see tables of Max. DC Current. Coil Materials Coil bobbins are molded in polybutylene with fiberglass (0 C). Enamelled wires of Class F specification are used ( C). They are wound on precision automation winding machines, with the number of turns and wire tension accurately regulated and monitored. Tolerances Coil resistance is measured at 0 C and is regulated within ±0% of specified value. Standard Windings The coil voltages indicated in the catalog refer to standard windings. Other coil voltages are available, including products for series connection and amperometric applications. Please consult your distributor for details. Terminology and Technical Information Maximum Itntensity The Max. switching current indicated in every model, refers to the maximum stable current which should be possible in permanent conduction (ITH). In the case of AC, the Max. switching current that the relay can support is the same for all the values of voltages of the Max. switching voltage specified in every model. The product of the intensity and the voltage applied should not be higher than the values specified as Max. AC load. In the case of DC, the Max. switching current must be less than the current that causes the continuous arcing. The tables of Max. DC current show the possible values of intensity in relation to the applied voltage. Maximum Voltage The maximum voltage on the contacts depends on the insulation between each contact (pole-to-pole) and between all contacts and the coil. The EN 09 and VDE 00 standards set out the maximum voltage values, taking into consideration the quality of the insulation materials, pollution degree as well as the shape and dimensions of the contact barriers (creepage distance). Contacts in Series The connection of two or more contacts in series is equivalent to multiplying the contact gap by that amount. By using this method, a greater break capacity is achieved for DC switching. Minimum Working Voltage (pull in) This is the minimum voltage that must be supplied to the coil to ensure that the relay energizes, the contacts change over and are positively held in place without any vibration. The values of voltage specified are those at or below which the relay must pull in. Working at: 0 Hz 0 Hz AC 0 Hz Relays 0.xU n 0.xU n AC 0 Hz Relays 0.xU n 0.xU n DC Relays 0. x U n Maximum Release Voltage (drop out) This is the voltage at which the relay de-energizes, the contacts change over and are positively held in place without any vibration. The values of voltage specified are those at or above which the relay must drop out. DC relays 0% U n AC relays 0% U n Contacts in Parallel The connection of two or more contacts in parallel does not mean that it is possible to switch a greater load. However, the stable current and the operational reliability of the relay is increased. Double Make Contacts The double make contact arrangement is equivalent to two contacts connected in series. The maximum intensity supported corresponds to only one contact. This system allows for higher DC operating voltages. Bifurcated (Twin) Contacts The contact blade is divided into two parts, each with its own contact. Both contacts press down on their own independent fixed contacts. This system is particularly good for switching at very low levels of current. Contact Protection The electrical life of contacts can be prolonged by components which eliminate or reduce the back EMF transients. These voltages are generated by the reactive component of the load on disconnection, which increases the duration and the temperature of the arc. For AC, RC suppressors or varistors can be connected in parallel with the load or the contacts. For DC with an inductive load, the best method is to connect a diode in parallel with the load. Ambient Temperature The ambient temperature has an influence on the coil resistance and on its thermal dissipation capacity. Curve represents the variations of the pull in voltage (% Un ) in relation with the ambient temperature (T). Curve indicates the maximum values of the voltage applied ( Ub ) to the coil in relation with the nominal voltage ( Un ) at the ambient temperature (T). B Fax: () -00 TURCK Inc. Minneapolis, MN U b /U n T C

9 General Information General Purpose Relays A These are used for most general applications, such as automation, pneumatic, heating appliances, signaling, as an input or output interface, etc. Change-over contacts. Isolation between N.O./N.C.: 000 V rms Gap: 0. mm Rating loads of up to: 0 V AC 0 V DC 0. 0 V DC 0. 0 V DC T Relays with Twin Contacts These are used to switch low currents with high operational reliability. Change-over contacts. Isolation between contacts N.O./N.C.: 000 V rms Gap: 0. mm Gold-flashed contact 0.µ or plated with 0µ Au (optional). Maximum load: 0 V AC Minimum load: V DC S E N Sensitive Relays, 0 mw One change-over contact Sensitive Relays, 00 mw Two change-over contacts Sensitive Relays, 00 mw Three change-over contacts DC relays adjusted to work at lower power, available in both MR-C and QR-C versions. Gold-flashed contacts 0.µ or plated 0µ Au (optional). Operational voltage range: S relays: U n E relays: U n N relays: U n Relay Types Based on Applications Relays with Open Contacts G An open contact arrangement allows an increase in the contact gap, increasing the DC break capacity without altering the AC performance. Gap:. mm(qr-c types);. mm(mr-c) Isolation of contacts NO: >000 V rms Maximum load: 0 V AC. 0 V DC 0. 0 V DC Double Make Relays X These relays are designed to switch high DC loads at voltages of 0 and 0 VDC. If consists of one normally open contact with a gap > mm so that the arc length is divided by two. Isolation between contacts: >000 V rms The max. DC load is shown in the tables. X versions are available in MR-C and QR-C type housing. High Inrush Current Relay W Two open contacts, one of silver nickel and one of tungsten work in parallel but are physically displaced so that the tungsten contact makes and breaks the load. The silver contact is used for carrying the stable current. This relay was designed to switch incandescent and fluorescent lamps, (with p.f corrected), and DC inductive loads. Only available in C type housing. Maximum loads: 0 V ACa/b (lamps) 0 0 V AC. 0 V DC Relays with Mag. Blow Out M These versions are similar to X types, however they have an addition of a powerful magnet which blows out the arc generated when the contacts are opened, therefore quenching the arcing quickly and increasing the contact life. They are able to switch DC loads of up to 0 V DC and 0 V DC Remanence Relays R A high remanence magnetic circuit allows the relay to latch positively when the current applied flows through the coil in a direction and delatches if the current flows in the opposite direction. Electronic circuitry is added inside the relay to control this action and also protects against transient voltages. There is one winding for AC coils and two windings for DC coils. All coils withstand permanent connection. The relay can be operated with pulses of 0 ms, minimum, at nominal voltage. The data referred to in the specifications for each model refers to typical values of new relays at 0 C. Tables The tables of electrical life and the tables of maximum DC current show the typical result of exhaustive tests performed at an ambient temperature of 0 C, operating frequency of,00 operations/hour, and under per manent connection. The switching current ratings specified in the catalog refer to a minimum electrical life of 00,000 operations. Margin of Over-Voltage Coils withstand, on permanent conection, a maximum over-voltage of 0 percent Un, with rated current through the contacts at an ambient temperature of 0 C. Custom Relays Relays with special specifications can be supplied after consultation with an official RELECO distributor. A + A + A A Fax: () -00 TURCK Inc. Minneapolis, MN B0 9

10 General Information MRC - QRC Protection Against Transients When the coil is disconnected from an electromagnet, peaks of inverse voltage appear at the terminals which can reach very high values. These pulses can be transmitted down the line associated with the coil and could possibly affect other components. In the case of a relay being operated by such devices as transistors, triacs, etc; it may be necessary to protect against transients. Transients Carried in the Line High voltage surges can be carried in the supply line to the relay coil. These may appear in the form of peaks or bursts and are generated by the connection and disconnection of electric motors, transformers, capacitors, etc. Normally a relay is unaffected by these pulses, but if a diode is connected in association with the coil, it must be capable of withstanding an inverse voltage higher than those of the incoming peaks. Protection Circuits A protection circuit must efficiently cope with pulses generated by the coil as well as incoming line surges (surges U./0µs.). RELECO relays are available with integrated protection circuits or with modules plugged into sockets S-MP or S-MS. A X Coil Accessories X LED indication with rectifier. For DC and AC relays up to 0 V Surges of 000 V up to V Surges of 000 V from to 0 V Surges of 000 V from to 0 V Note: LED connected in series with the 0 VDC in QRC types. D Free-wheeling diode. DX Free-wheeling diode + LED Dampens transients caused by the relay coil on de-energization. Surges of 000 V up to 0 VDC Surges of 000 V from to 0 VDC (*) F Polarity and free wheeling diodes. FX Polarity + free wheeling diode + LED A diode in series with the coil protects the relay from reverse connection. Surges of 000 V up to 0 VDC Surges of 000 V from to 0 VDC (*) B Bridge rectifier incorporated. BX Bridge rectifier + LED indication. Allows the relay to operate in both AC or DC without any polarity inconvenience. Available only in voltages up to 0 V Surges of 000 V R Resistor and capacitor. Suppressor for AC coils. Surges of 000 V Available only in MRC types (*) Surges of 000 V in QRC types. + A F A + FX IRC LED and protection circuit connected to coil. X LED with no polarity, (standard) Coils V CC and CA LED rectifier bridge in parallel X LED with no polarity, (standard) Coils V CC and CA LED rectifier bridge in series FX LED with polarity A+ (option) Every DC coil voltage Polarity and Free-wheeling diodes BX LED with no polarity, (option) Only V and V AC/DC coils Rectifier bridge for AC/DC relays R LED not available (option) Every AC coil voltage RC protection against pulses on AC Protection Against Pulses When a relay coil is disconnected, reverse voltage peaks may arise and reach very high values. Said peaks can transmit to the coil associated line and other relays or semiconductors can be affected. If triac, transistor, etc. controls a relay, appropriate steps must be taken to avoid or decrease peaks down to a non-risky level. Both polarity and free-wheeling diodes (FX), must protect coils, to avoid malfunctions, provided DC relays in battery are installed. Making or breaking engines, transformers or contactors in an industrial environmental, may generate high voltage pulses, either isolated or burst, through the main line. The voltage level of those pulse may be high enough to affect the isolation of the coil. LED consumption: ma Increases release time approx. times X V BX A + D DX B BX A A A + Increases release time approx. times Increases release time approx. times X V FX R A R 0 B Fax: () -00 TURCK Inc. Minneapolis, MN

11 IRC Interface Applications Total Interconnection, Bridge Bars for Coil and Power Lines Bridge Bars Connection on S0-M and S Sockets Examples of mounting. Not at scale. New S0-M and S sockets and new connection bridges B0, V0 and V0 permit quick and easy wiring for relays in battery, in groups or in any other combination of voltages, coils or contacts. Every bridge allows mounting with a hybrid configuration of S0-M and S sockets. The immediate identification of the different circuits means a lower mounting cost, inspection or maintenance. Available in grey (standard), red (AC) and blue (DC), following the same color coding adopted by RELECO in testing buttons to identify its relays. V0 Bridge Bars for Power Lines V0 bridges allow joining common points in the power connection, usually the change-over contacts or on relays. They can be also used to bridge NC or NO terminals. V0 bridges join four similar points in four adjacent sockets. They can join among themselves or to V0 units to bridge an unlimited number of sockets in any combination. Made of copper with a current capacity of 0 A. V0 Bridge Bars for Power Lines V0 bridges connect a single socket to the next socket, so can you bridge less or more than four sockets, as long as the total number of sockets is not a multiple of four. They can join between themselves or to V0 units. If you need to bridge five sockets, you can either use a V0 + V0 or four V0 bridges. Made of copper with a current capacity of 0 A. It is necessary that the total sum of loads in a relay group will not exceed the maximum intensity of 0 A, permitted by the power bridges. If exceeded, the essential power cables must be added, to share the current and avoid overheating the bridges. Every inlet terminal admit ferrule tips up to sq. mm. DC V Power supply for loads at points and DC V Power supply for loads at points and AC 0 V Power supply for loads at points and V0 bridge V0 bridge V0 bridges Pole Relay AC 0 V -Pole Relay AC 0 V -Poles Relay DC V -Poles Relay DC V -Poles Relay DC V -Poles Relay DC V -Pole Relay AC V -Pole Relay AC V -Pole Relay AC V S0-M S0-M S S S S S0-M S0-M S0-M A A A A A A A A A A AC 0 V Common DC V Common B0 bridges B0 bridges AC V Common B0 Bridge Bars for Coil Lines Both sockets are accessible to point from terminals and, internally connected. Each element connects point of the first socket to point of the next one, always leaving free the point of the first socket and the point of the last one, to connect the common polarity cable. Coils control voltage connect to points A. Bridge B0 is composed by four units which can be divided in, or elements Fax: () -00 TURCK Inc. Minneapolis, MN B0

12 IRC Interface Applications Total Interconnection, Bridge Bars for Coil and Power Lines V0 V0 B0 Power Bridge Bars for Sockets Coil Bridge Bars for Sockets S0-M and S S0-M and S V0 bridges join four similar points in four adjacent sockets. They can join among themselves or to V0 units to bridge an unlimited number of sockets S0-M and S in any combination. V0 bridges connect a single socket to the next socket, so you bridge less or more then four sockets. Made of copper with a current capacity of 0 A. B0 bridges points, internally connected, of every adjacent socket S0-M or S. Each element connects point of the first socket to point of the next one, always leaving free the point of the first socket and the point of the last socket, to connect the common polarity cable. See more information on page. See more information on page. V0-G V0-G B0-G V0-R V0-R B0-R V0-A V0-A B0-A IEC 0 EN 09 IRC relays, E version Types C... and C... Cover for flange panel mounting Ordering code: Add E to the standard type code. Example: C-A0E or C-E B Fax: () -00 TURCK Inc. Minneapolis, MN

13 IRC Interface Applications Total Interconnection, Bridge Bars for Coil and Power Lines I/O sockets, IRC relays and bridge bars allow more flexible, economical and aesthetic mounting in interface and general applications. B0 Bridge Bars for Coil Line Common Polarity Cable for Coils S0-M and S sockets of and contacts, with inlets in line and identical disposition of contacts set. Identical sequence of coil and contacts on both sockets. Coil terminal on level : (,, A) Contact terminals on level : (,, ) Contact terminals on level : (,, ) Bridge bars between coil terminals with free inlets to connect a commom polarity cable. Those bridge bars are isolated and divisible by hand, in single units. Power bridges with current capacity of 0 A to be connected between contacts or in any combination: Groups or battery of relays, to supply the power current to the loads. Inlet terminals admit ferrule tips up to mm. Bridges in grey color as standard. Options: Adopted colors by RELECO used in the testing buttons of relays: Blue, to identify DC circuits Red, to identify AC circuits V0 and V0 Bridge Bars for Power Line Common Power Supply Cable for Loads Fax: () -00 TURCK Inc. Minneapolis, MN B0

14 IRC Interface Applications Total Interconnection, Solid State Relays How to Mount Solid State Relays as Interface on PLC Input In every CSS relay, the input on terminals A and is - VDC, with no polarity. If bridges to joint points are used, a single voltage can be applied on terminals A, for every relay, or different voltages within the range - VDC. Output DC or AC (Independent Relays) When using a single relay of any model, load can be connected either on terminal or terminal. Relays with Output on DC (CSS-DCP or CSS-DCN). Range of voltage applied to the load will be -0 VDC. Relays with Output on AC (CSS-AC, Inductive Loads, or CSS-AZ, Resistive Loads). Range of voltage applied to the load will be -0 VAC, 0/0 Hz. Output on DC (Relays in Battery) If power bridges are used with S0-M sockets in series of relays in line, it is necessary to attend the common polarity chosen to the loads connection. Usually the point ( DIN) is the common point of the socket where positive tension is applied to the loads. Then CSS-DCP relays must be connected where terminal is common positive. Said disposition complies Norm EN-00--,, where cutting every active element of its feeding is suggested, that means to switch from the positive. If point of the socket is taken as negative, relays type CSS- DCN, where terminal is negative must be connected. For relays CSS-AC or CSS-AZ, only whether the load is inductive or resistive has to be considered, as they have no polarity. - 0 VDC + Load Load Load - 0 VDC + PLC Input Terminals Input Input Input CSS-DCP CSS-DCP CSS-DCP CSS-DCP C0-TX CSS-DCP S0-M S0-M S0-M S0-M S0-M S0-M A A A A A A ± - VDC ± Out Out Out PLC Output Terminals VDC + Sensor PNP Switch Sensor PNP - 0 VAC Load A Ind. Load A Res. Load A Ind. Load A Res. Load A Ind. Load 0A Res. Load A Res. Load A Ind. SS-AC CSS-AZ CSS-AC CSS-AZ C0-A0X C0-A0X C0-A0X CSS-AC S0-M S0-M S0-M S0-M S0-M S0-M S0-M S0-M A A A A A A A A ± VDC ± Out Out Out Out Out Out Out Out PLC Output Terminals B Fax: () -00 TURCK Inc. Minneapolis, MN

15 RELAYS Fax: () -00 TURCK Inc. Minneapolis, MN B0

16 MRC -Pole, Standard -Pin Plug-In Relay Relay compatible with sockets: S-B, S-S, S-L, S-PO C-0 General purpose Two pole, change-over contacts 0 A 0 V AC 0. A 0 V DC 0 A 0 V DC 0. A 0 V DC A(+) Contacts Materials: Standard, code 0 AgNi Optional, code AgNi + 0µ Au Optional, code 9 AgNi + 0.µ Au Max. switching current 0 A Max. peak inrush current (0 ms) 0 A Max. switching voltage 0 V Max. AC load (Table ). KVA Max. DC load (Table ) Table Electrical Life, ops. x 0 Coils (Ohms 0 C) Pull-in voltage Drop-out voltage Nominal coil power 0. x U n 0. x U n. VA (AC)/. W (DC) VAC Ω ma VDC Ω ma 9 9 K K 9 0 9K 0 K 9. 0 K Table Max. DC Load Insulation Dielectric strength ( minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 00 V Isolation, IEC 0-:,000 V. KV. KV GΩ. KV/ Operate time + bounce time ms Release time + bounce time ms Ambient temperature -0 C (no ice) to +0 C Mechanical life ops. 0 Mill. AC, 0 Mill. DC relay Electrical life at nominal load 00,000 ops. Operating frequency at nominal load,00/hour Protection degree IP 0/RT Weight avg. 90 g. A Standard Types AC 0 Hz, (0 Hz):,,, (0), 0, (0) X = LED (standard) C-0X...VAC RC suppressor C-0R...VAC DC,, 0, 0 X = LED, no polarity (standard) C-0X... VDC Free-wheeling diode C-0DX... VDC Polarity and free-wheeling diodes C-0FX... VDC AC/DC bridge rectifier (, or 0 V) C-0BX... VDC Lloyd s IEC 0 EN 09 B Fax: () -00 TURCK Inc. Minneapolis, MN

17 MRC -Pole, Twin Contacts -Pin Plug-In Relay Relay compatible with sockets: S-B, S-S, S-L, S-PO C-T Low level Two change-over bifurcated contacts A 0 V AC A 0 V DC Min. contacts load: ma / V DC A(+) Contacts Materials: Standard, code AgNi + 0.µAu Optional, code AgNi + 0µAu Max. switching current A Max. peak inrush current (0 ms) A Max. switching voltage 0 V Max. AC load (Table ). KVA Max. DC load (Table ) Table Electrical Life, ops. x 0 0 Coils (Ohms 0 C) Pull-in voltage Drop-out voltage Nominal coil power 0. x U n 0. x U n. VA (AC)/. W (DC) Ops. AC VAC Ω ma VDC Ω ma 9 9 K K 9 0 9K 0 K 9. 0 K 0. 0 Table VA 0 Max. DC Load Insulation Dielectric strength ( minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 00 V Isolation, IEC 0-:,000 V. KV. KV GΩ. KV/ Operate time + bounce time ms Release time + bounce time ms Ambient temperature -0 C (no ice) to +0 C Mechanical life ops. 0 Mill. AC, 0 Mill. DC relay Electrical life at nominal load 00,000 ops. Operating frequency at nominal load,00/hour Protection degree IP 0/RT Weight avg. 90 g A Standard Types AC 0 Hz, (0 Hz):,,, (0), 0, (0) X = LED (standard) C-TX...VAC RC suppressor C-TR...VAC. DC,, 0, 0 X = LED, no polarity (standard) C-TX... VDC Free-wheeling diode C-TDX... VDC Polarity and free-wheeling diodes C-TFX... VDC AC/DC bridge rectifier (, or 0 V) C-TBX... VDC IEC 0 EN Fax: () -00 TURCK Inc. Minneapolis, MN B0

18 MRC C-G0 General purpose, DC applications Two pole open contacts 0 A 0 V AC. A 0 V DC 0 A 0 V DC 0. A 0 V DC Contacts Materials: Standard, code 0 AgNi Max. switching current 0 A Max. peak inrush current (0 ms) 0 A Max. switching voltage 0 V Max. AC load (Table ). KVA Max. DC load (Table ) Coils (Ohms 0 C) Pull-in voltage Drop-out voltage Nominal coil power 0. x U n 0. x U n. VA (AC)/. W (DC) Insulation Dielectric strength ( minute): Open contacts,000 V Between adjacent poles. KV Between contacts and coil. KV Isolation resistance at 00 V GΩ Isolation, EN 0-:. KV / Operate time + bounce time 0 ms Release time + bounce time 0 ms Ambient temperature -0 C (no ice) to +0 C Mechanical life ops. 0 Mill. AC, 0 Mill. DC relays Electrical life at nominal load 00,000 ops. Operating frequency at nominal load,00/hour Protection degree IP 0/RT Weight avg. 90 g A Standard Types AC 0 Hz, (0 Hz):,,, (0), 0, (0) X = LED (standard) C-G0X...VAC RC suppressor C-G0R...VAC -Pole, Standard -Pin Plug-In Relay Gap. mm Relay compatible with sockets: S-B, S-S, S-L, S-PO A(+) Table Electrical Life, ops. x 0 VAC Ω ma VDC Ω ma K K 0 K 0 K 0 0 0K. Table Max. DC Load. DC,, 0, 0 X = LED, no polarity (standard) C-G0X... VDC Free-wheeling diode C-G0DX... VDC Polarity and free-wheeling diodes C-G0FX... VDC AC/DC bridge rectifier (, or 0 V) C-G0BX... VDC IEC 0 EN 09 B Fax: () -00 TURCK Inc. Minneapolis, MN

19 MRC -Pole, Standard -Pin Plug-In Relay 9 Relay compatible with sockets: S-B, S-S, S-MP, S-MS, S-L, S-PO A(+) 0 C-A0 General purpose Three pole, change-over contacts 0 A 0 V AC 0. A 0 V DC 0 A 0 V DC 0. A 0 V DC Contacts Materials: Standard, code 0 AgNi Optional, code AgNi + 0µ Au Optional, code 9 AgNi + 0.µ Au Max. switching current 0 A Max. peak inrush current (0 ms) 0 A Max. switching voltage 0 V Max. AC load (Table ). KVA Max. DC load (Table ) Table Electrical Life, ops. x 0 0 Coils (Ohms 0 C) Pull-in voltage Drop-out voltage Nominal coil power 0. x U n 0. x U n. VA (AC)/. W (DC) Ops. AC AC Cos AC ϕ 0. VAC Ω ma VDC Ω ma 9 9 K K 9 0 9K 0 K 9. 0 K 0. Table KVA Max. DC Load Insulation Dielectric strength ( minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 00 V Isolation, IEC 0-:,000 V. KV. KV GΩ. KV/ Amps. 0. DC DC L/R DC 0ms Volts Operate time + bounce time ms Release time + bounce time ms Ambient temperature -0 C (no ice) to +0 C Mechanical life ops. 0 Mill. AC, 0 Mill. DC relays Electrical life at nominal load 00,000 ops. Operating frequency at nominal load,00/hour Protection degree IP 0/RT Weight avg. 90 g 0 A Standard Types AC 0 Hz, (0 Hz):,,, (0), 0, (0) X = LED (standard) C-A0X...VAC RC suppressor C-A0R...VAC. 9 DC,, 0, 0 X = LED, no polarity (standard) C-A0X... VDC Free-wheeling diode C-A0DX... VDC Polarity and free-wheeling diodes C-A0FX... VDC AC/DC bridge rectifier (, or 0 V) C-A0BX... VDC Lloyd s IEC 0 EN Fax: () -00 TURCK Inc. Minneapolis, MN B0 9

20 MRC -Pole, Twin Contacts -Pin Plug-In Relay 9 A(+) 0 Table Electrical Life, ops. x 0 0 Relay compatible with sockets: S-B, S-S, S-MP, S-MS, S-L, S-PO C-T Low level Three change-over bifurcated contacts A 0 V AC A 0 V DC Min. contacts load: ma / V DC Contacts Materials: Standard, code AgNi + 0.µAu Optional, code AgNi + 0µAu Max. switching current A Max. peak inrush current ( ms) A Max. switching voltage 0 V Max. AC load (Table ). KVA Max. DC load (Table ) Coils (Ohms 0 C) Pull-in voltage Drop-out voltage Nominal coil power 0. x U n 0. x U n. VA (AC)/. W (DC) Ops. AC VAC Ω ma VDC Ω ma 9 9 K K 9 0 9K 0 K 9. 0 K 0. 0 Table VA 0 Max. DC Load Insulation Dielectric strength ( minute): Open contacts,000 V Between adjacent poles. KV Between contacts and coil. KV Isolation resistance at 00 V GΩ Isolation, IEC 0-:. KV / Amps Volts 0 DC A Operate time + bounce time ms Release time + bounce time ms Ambient temperature -0 C (no ice) to +0 C Mechanical life ops. 0 Mill. AC, 0 Mill. DC relays Electrical life at nominal load 00,000 ops. Operating frequency at nominal load,00/hour Protection degree IP 0/RT Weight avg. 90 g Standard Types AC 0 Hz, (0 Hz):,,, (0), 0, (0) X = LED (standard) C-TX...VAC RC suppressor C-TR...VAC. 9 DC,, 0, 0 X = LED, no polarity (standard) C-TX... VDC Free-wheeling diode C-TDX... VDC Polarity and free-wheeling diodes C-TFX... VDC AC/DC bridge rectifier (, or 0 V) C-TBX... VDC IEC 0 EN 09 0 B Fax: () -00 TURCK Inc. Minneapolis, MN

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

60 Series - General purpose relays 6-10 A. Features 60.12 60.13

60 Series - General purpose relays 6-10 A. Features 60.12 60.13 Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

MRC, QRC & IRC SERIES. Application Poles AC ratings DC ratings Page Sockets Page 2 C 3 C 4 C 2 C 3 C 1 C 2 C 4 C 1 C 2 NO 3 NO 3 NO 2 NO

MRC, QRC & IRC SERIES. Application Poles AC ratings DC ratings Page Sockets Page 2 C 3 C 4 C 2 C 3 C 1 C 2 C 4 C 1 C 2 NO 3 NO 3 NO 2 NO Relays Full Featured Industrial Plug-In Relays ingle Pole Interface to Four Pole Power witching Low Level ignal to High Power DC witching Latching & Low Consumption Coil Options Plug In Timer Cube Options

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52

40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52 Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic

More information

SKR - industry relay

SKR - industry relay SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,

More information

Elesta Elektrotechnik AG industry relays and accessories

Elesta Elektrotechnik AG industry relays and accessories Elesta Elektrotechnik AG industry relays and accessories edition 003 table of contents SKR-industry relay 4 SKR-screw socket with accessories 4 SFR-industry relay 6 SFR-screw socket with accessories 7

More information

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51 34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in

More information

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules CHIEF EN TERPRISES INC. M a s t e r I n t e r n a t i o n a l D i s t r i b u t o r Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules M AS TER IN

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc. Crydom RHP Series 3 Phase Hybrid Solid State Contactor By Paul Bachman Fellow Engineer, Crydom, Inc. ABSTRACT Solid State Relays and Contactors (SSRs) have been available in one form or the other for over

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

AZ420 MINIATURE GENERAL PURPOSE RELAY

AZ420 MINIATURE GENERAL PURPOSE RELAY MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 0 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available

More information

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Siemens Protection Devices Limited 2 7PG17 XR101 & XR102 Intertripping Relay

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1 Power PCB Relay G2R Creepage distance of 8.0 mm (0.31) min. between coil and contact. Dual-winding latching type available. Plug-in and quick-connect terminals available. High sensitivity (360 mw) and

More information

Data Sheet. Electro-mechanical counters Hengstler 800 series

Data Sheet. Electro-mechanical counters Hengstler 800 series Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from

More information

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN --- --- contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND --- ---

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN --- --- contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND --- --- PCB Relay A Power Relay for a Variety of Purposes with Various Models Conforms to VDE045 (VDE approval: C2 insulation grade), UL8, CSA22.2, SEV, SEMKO. Meets VDE0700 requirements for household products

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE DATA SHEET MINIATURE SIGNAL RELAY EC SERIES COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE DESCRIPTI The EC series has reduced mounting space but sustained high-performance of NEC

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Model Number Structure

Model Number Structure General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with

More information

Model Number Structure

Model Number Structure General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

Signal Relays AXICOM. P2 Relay V23079. AXICOM Telecom-, Signal and RF Relays. P2 V23079 Relay. Coil Operating Range. Coil Data

Signal Relays AXICOM. P2 Relay V23079. AXICOM Telecom-, Signal and RF Relays. P2 V23079 Relay. Coil Operating Range. Coil Data P Relay V379 n Standard telecom relay (ringing and test access) n Slim line 5x7.5mm (.59x.95 ) n Max. switching current 5A n form C bifurcated contacts ( changeover contacts, CO) n Immersion cleanable

More information

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Proximity Switches RS (Reed Switch)

Proximity Switches RS (Reed Switch) Proximity Switches RS (Reed Switch) General Pneumatic systems can often be combined with electric control circuits. The position of the piston in the cylinder can then be sensed by means of a proximity

More information

General-purpose Relay

General-purpose Relay General-purpose Relay An Improved Miniature Power Relay with Many Models for Sequence Control and Power Applications A wide range of relay variations including ones with operation indicators, high-capacity

More information

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control Power Relay FEATURES Small package design ARC barrier equipped Silver Cadium Oxide contact High dielectric strength (,800 Vac) High reliability and long life Ultra-high sensitivity with quick response

More information

FP2 Relay. The Best Relaytion

FP2 Relay. The Best Relaytion The Best Relaytion 2 pole telecom / signal relay Through Hole Type (THT) Polarized. Relay types: non-latching with1 coil latching with 1 coil latching with 2 coils Features Telecom / signal relay (dry

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories s RT series Miniature Printed Circuit oard Relays, Sockets and ccessories pplied Coil Voltage (% of rated nom.) RT series (DC Coil) 6 mp PC oard Miniature Relay Meets VDE 0mm Spacing, KV Dielectric File

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

MULTIFUNCTION TIME RELAY CRM-93H

MULTIFUNCTION TIME RELAY CRM-93H 4 MULTIFUNCTION TIME RELAY CRM-93H - 10 functions Features: Universal supply voltage AC/DC 12-240V 10 functions: - 5 time functions controlled by supply voltage - 4 time functions controlled by control

More information

The Best Relaytion. Reed Relays. 108-98011 Rev. B EC-JM00-0009-03 ECOC: JM10 1. Aug. 04

The Best Relaytion. Reed Relays. 108-98011 Rev. B EC-JM00-0009-03 ECOC: JM10 1. Aug. 04 The Best Relaytion Reed Relays 108-98011 Rev. B EC-JM00-0009-03 ECOC: JM10 1. Aug. 04 1 and 2 pole relays non-polarized, non-latching Features Direct coil control with TTL-signals possible Highly reliable

More information

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type K only) FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) HIGH INSULATION Insulation distance (between coil and

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5 T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES POWER RELAY 1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES RoHS compliant FEATURES Ultra slim type with 5 mm thickness Good for high density mounting Low power consumption and high sensitivity Nominal

More information

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E PCB Power elay The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

1 POLE - 5A SLIM POWER RELAY

1 POLE - 5A SLIM POWER RELAY POWER RELAY POLE - A SLIM POWER RELAY FTR-MY Series RoHS compliant FEATURES Width mm, height mm,(% smaller than NY series) area mm, super slim, low power, compact and light weight.gr. Nominal power: mw

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

RC NETWORKS SALES GUIDE

RC NETWORKS SALES GUIDE SALES GUIDE INTRODUCTION TO Recent developments in electronic equipment have shown the following trends: Increasing demands for numerical control machines, robotics and technically advanced appliances

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal

93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal Series - Timed socket for 34 series Features.68/.69 Slim timed sockets for 34 series, 6.2 mm wide Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011 , 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially

More information

Description Part-No. Type PU. Nominal voltage DC12V 768001 Relais-SNR 12V 1W 20 DC 24 V 768002 Relais-SNR 24V 1W 20

Description Part-No. Type PU. Nominal voltage DC12V 768001 Relais-SNR 12V 1W 20 DC 24 V 768002 Relais-SNR 24V 1W 20 Replacement relay, 1COcontact, 6 A, : AgSnO 2,AgSnO 2 +5 µm HV Relay with AgSnO 2 Nominal voltage DC12V 768001 Relais-SNR 12V 1W 20 768002 Relais-SNR 24V 1W 20 DC 60 V 768003 Relais-SNR 60V 1W 20 Relay

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

Telemecanique Zelio Relay complementary and easy to assemble

Telemecanique Zelio Relay complementary and easy to assemble Telemecanique Zelio Relay complementary and easy to assemble Get more with the world s Power & Control specialist RS interface relays Compact dimensions, enabling multiplication of contacts in electrical

More information

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES POWER RELAY POLE - 6A / Inrush 20A relay FTR-K-KS Series FTR-K SERIES FEATURES pole 6A, form A or form C Peak inrush current 20A / TV-8 Coil power 400mW High insulation in small package (between coil and

More information

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS LOW-PROFILE SURFACE-MOUNT RELAY RELAYS.55 5.6. FEATURES Low-profile: 6 mm.36 inch (Tape height: max. 6.5 mm.56 inch) Tape and reel package is available as standard packing style Surge withstand between

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

CQM1-SF200/CS1W-SF200

CQM1-SF200/CS1W-SF200 Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII

(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII Non-promotional not for new designs FTR-K1 SERIES POWER RELAY 1 POLE - 10A VS Series FEATURES UL, CSA, VDE, SEV, SEMKO, CQC recognized TV-5 is available Working class: C UL class B (130 C) coil wire insulation

More information

AXICOM Telecom-, Signal and RF Relays. Cradle Relay S V23054 / V23062. 108-98014 Nov. 07 Rev. C ECOC: JM10

AXICOM Telecom-, Signal and RF Relays. Cradle Relay S V23054 / V23062. 108-98014 Nov. 07 Rev. C ECOC: JM10 Cradle Relay S V23054 / V23062 108-98014 Nov. 07 Rev. C ECOC: JM10 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics

More information

Ordering Information. Latching Relay G2AK. Model Number Legend G2AK-@@@@@ 1 2 3 4 5. Magnetic Latching Version of G2A Ideal for Sequence Control

Ordering Information. Latching Relay G2AK. Model Number Legend G2AK-@@@@@ 1 2 3 4 5. Magnetic Latching Version of G2A Ideal for Sequence Control Latching Relay CSM DS_E_4_1 Magnetic Latching Version of G2A Ideal for Sequence Control Double-winding latch system with continuous rating. Terminals pulled from the respective junctions between the built-in

More information

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) FBR46 SERIES RoHS compliant FEATURES Miniature size About 50% smaller in volume compared with the FBR240 series used mainly in communication equipment.

More information

Product Catalogue. Relays with forcibly guided contacts

Product Catalogue. Relays with forcibly guided contacts Product Catalogue Relays with forcibly guided contacts Product Catalogue - Relays with forcibly guided contacts Edition / Publisher: ELESTA relays GmbH, Bad Ragaz, Switzerland All rights reserved. This

More information

RELAYS Solar Energy Systems

RELAYS Solar Energy Systems RELAYS Solar Energy Systems FUJITSU COMPONENTS CONTENTS Fujitsu relays for solar applications DC voltage versions - AC voltage versions - Latching versions RELAY PRODUCT LINE UP - SOLAR ENERGY SYSTEMS

More information

Solid-State Relays (SSRs) vs Electromechanical Relays (EMRs)

Solid-State Relays (SSRs) vs Electromechanical Relays (EMRs) Oct 2010 Solid-State Relays (SSRs) vs Electromechanical Relays (EMRs) A study on worldwide relays market found the market size of solid state relays to be between $200M and $600M, which represent 17% of

More information

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

2 POLES - 5A LOW PROFILE TYPE

2 POLES - 5A LOW PROFILE TYPE FTR-K1 SERIES POWER RELAY 2 POLES - 5A LOW PROFILE TYPE FTR-F1 Series FEATURES Low profile (height: 16.5mm) DPST/DPDT 5A, TV-3 rating available High insulation (due to its reinforced insulation construction)

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES FTR-K1 SERIES SILENT POWER RELAY 1 POLE - 78A/120A Inrush Current Type FTR-H3 Series FEATURES Pin compatible with widely used VS and FTR-H1 series power relays Silent relay with patented unique U-shape

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),

More information

mpm DIN 43650 CONNECTORS

mpm DIN 43650 CONNECTORS mpm DIN 43650 CONNECTORS : Highest quality, robust connectors for hydraulic and pneumatic electromechanical devices Broad offering of DIN 43650 connectors and devices Combined Brad and mpm cordsets : Provide

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information