Industry s First Modular Fuse Blocks Simplify Design and Enhance Safety Class R, H(K), & J Fuse Applications up to 600 Amps

Size: px
Start display at page:

Download "Industry s First Modular Fuse Blocks Simplify Design and Enhance Safety Class R, H(K), & J Fuse Applications up to 600 Amps"

Transcription

1 Industry s First Modular Fuse Blocks Simplify Design and Enhance Safety Class R, H(K), & J Fuse Applications up to 600 Amps

2 Protection made simple

3 Knifeblade Fuse Blocks with IP0 Finger-Safe Covers Cooper Bussmann knifeblade fuse blocks offer a set of advantages you can t find anywhere else. Modularity The only snap-together design on the market permits assembly of required poles at point-of-use. Factory assembled two- and three-pole configurations are also available. Best Ratings All fuse blocks meet UL creep and clearance requirements for Industrial Control Circuits (UL 508, UL 845). 00 Amp and above blocks meet the higher UL Industrial Power Distribution Standards (UL 98, UL 67, UL 489, UL 891, and UL 869A). Ease-of-Use Optional high-clarity, see-through finger-safe covers with test probe holes make routine maintenance activities easy. No need to open the cover to inspect wire terminations or to take thermography measurements. Available with any Class J, H(K) or R fuse block. Safety For added safety and convenience, only Cooper Bussmann offers optional IP0 finger-safe covers across the entire knifeblade fuse block range. Built-in lockout/ tagout feature improves safety. Blown fuse indication option on fuse cover assists in troubleshooting, while standard phase barriers between poles enhance safety. and Service In stock for QuikShip Everyday Service - 90% of orders ship within 4 hours. Quik- Ship Emergency Service ensures availability 4/7, 365 with Next flight out courier service. For more information visit 3

4 Knifeblade Fuse Block Features & Specifications Features and Benefits Integral dovetails allow snapping together multiple poles at point-of-use for greater application flexibility Factory assembled two- and three-pole configurations available Up to four mounting holes per pole increase installation flexibility Standard phase barriers between poles for additional safety Design meets UL creep and clearance requirements for Industrial Power Circuits (UL 508 and UL 845) 00 to 600A blocks meet the higher UL creep and clearance requirements for Power Distribution Standards (UL 98, UL 69, UL 489, UL 891 and UL 869A) Optional IP0 finger-safe covers available on entire knifeblade fuse block product line: High-clarity see-through covers allow for inspecting wire terminations or thermography measurements without removing cover Probe holes included for easy, safer testing and troubleshooting Built-in lockout/tagout feature improves safety Standard fuse clip reinforcing springs enhance electrical contact Specifications Agency Information: Blocks UL - Listed culus E14853 IZLT & IZLT7 CSA - Certified Covers UL - Listed UL E58836 JDVS CSA - Certified Ratings: Volts: 50V, 600V Amps: A SCCR: 00kA (Class R & J) 10kA (Class H & K) Flammability Ratings: Blocks UL 94V0, self-extinguishing Covers UL 94HB, self-extinguishing Operating & Storage Temperature Range: Blocks -40ºC to 10ºC Covers Non-indicating covers -40ºC to 10ºC Indicating covers -0ºC to 90ºC Materials: Base Thermoplastic Box Lug Tin-plated aluminum Wire:* Cu/Al 75ºC/90ºC (100-00A) Cu/Al 75ºC only ( A) *Higher temperature rated wire can be used with appropriate derating. 4 For more information visit

5 Knifeblade Fuse Block Feature Highlights Features Optional Blown Fuse Indication Speeds Troubleshooting Lockout/Tagout Feature Improves Safety Optional See- Through, Snap-on Cover for Easy Visual Inspection* Vent Slots Improve Cooling Probe Holes for Easy Testing Without Removing Cover Finger Grips on Cover for Easy Removal Standard Phase Barriers for Additional Safety Multiple Mounting Holes for Each Pole Provide Flexible, Secure Mounting Toolless Interlocking Modular Design for Easy Point-of-Use Assembly Finger-Safe Wire Entry with Cutout Tabs for Larger Wires 600A Version (with double box lug for easier wiring with smaller, dual conductors) *No fuse derating necessary. For more information visit 5

6 Knifeblade Fuse Block Part Number Table 50V Class R & H(K) 600V Class R & H(K) Class J Catalog Number Covers* Fuse Range Number Wire Range Wire Range Torque Cooper Bussmann Class H(K) Class R w/o Indication w/ Indication Volts (amps) of Poles (solid and stranded)*** (fine stranded Cu) Nm (Lb-in) Fuses HM5100-1CR RM5100-1CR AWG 6. (55) 1/0-3 AWG; () Cu 4-6 AWG 4-6 AWG 5.6 (50) Class H(K): 70- HM5100-CR RM5100-CR CVR-RH-5100 CVRI-RH AWG; () Cu 8 AWG 8 AWG 5.1 (45) NON AWG; () Cu AWG 4.5 (40) HM5100-3CR RM5100-3CR 3 Cu AWG; Al 10-1 AWG 4.0 (35) HM500-1CR RM500-1CR 1 Class R: MCM-1 AWG 3/0-1 AWG 4 (375) HM500-CR RM500-CR CVR-RH-500 CVRI-RH-500 LPN-RK_SP 00-6 AWG; () Cu -6 AWG -6 AWG 31 (75) HM500-3CR RM500-3CR 50 3 LPN-RK_SPI** HM5400-1CR RM5400-1CR 1 600kcmil 57 (500) FRN-R 5-500kcmil-4 AWG 51 (450) KTN-R HM5400-CR RM5400-CR CVR-RH-5400 CVRI-RH-5400 N/A 400 () Cu 3/0-4 AWG 57 (500) HM5400-3CR RM5400-3CR 3 () Al 3/0-4 AWG 34 (300) HM5600-1CR RM5600-1CR HM5600-CR RM5600-CR CVR-RH-5600 CVRI-RH-5600 () 500kcmil-4 AWG N/A 51 (450) 600 HM5600-3CR RM5600-3CR 3 HM CR RM CR AWG 6. (55) 1/0-3 AWG; () Cu 4-6 AWG 4-6 AWG 5.6 (50) Class H(K): HM60100-CR RM60100-CR CVR-RH CVRI-RH AWG; () Cu 8 AWG 8 AWG 5.1 (45) NOS 8 AWG; () Cu AWG 4.5 (40) HM CR RM CR 3 Cu AWG; Al 10-1 AWG 4.0 (35) HM6000-1CR RM6000-1CR 1 Class R: MCM-1 AWG 3/0-1 AWG 4 (375) HM6000-CR RM6000-CR CVR-RH-6000 CVRI-RH-6000 LPS-RK_SP 00-6 AWG; () Cu -6 AWG -6 AWG 31 (75) HM6000-3CR RM6000-3CR LPS-RK_SPI** HM CR RM CR 1 600kcmil 57 (500) FRS-R 5-500kcmil-4 AWG 51 (450) KTS-R HM60400-CR RM60400-CR CVR-RH CVRI-RH N/A 400 () Cu 3/0-4 AWG 57 (500) KWS-R HM CR RM CR 3 () Al 3/0-4 AWG 34 (300) PVS-R HM CR RM CR HM60600-CR RM60600-CR CVR-RH CVRI-RH () 500kcmil-4 AWG N/A 51 (450) 600 HM CR RM CR 3 Catalog Number Covers* Fuse Range Number Wire Range Wire Range Torque Cooper Bussmann Class J w/o Indication w/ Indication Volts (amps) of Poles (solid and stranded) (fine stranded) Nm (Lb-in) Fuses JM CR AWG 6. (55) JM60100-CR CVR-J CVRI-J /0-3 AWG; () Cu 4-6 AWG 4-6 AWG 5.6 (50) AWG; () Cu 8 AWG 8 AWG 5.1 (45) AWG; () Cu AWG 4.5 (40) JM CR 3 Cu AWG; Al 10-1 AWG 4.0 (35) JM6000-1CR MCM-1 AWG 3/0-1 AWG 4 (375) JM6000-CR CVR-J-6000 CVRI-J-6000 LPJ_SP 00-6 AWG; () Cu -6 AWG -6 AWG 31 (75) JM6000-3CR LPJ_SPI** JM CR 1 600kcmil 57 (500) JKS JM60400-CR CVR-J CVRI-J kcmil-4 AWG 51 (450) DFJ N/A 400 () Cu 3/0-4 AWG 57 (500) JM CR 3 () Al 3/0-4 AWG 34 (300) JM CR JM60600-CR CVR-J CVRI-J JM CR 3 () 500kcmil-4 AWG N/A 51 (450) *Covers sold serarately. Blown fuse indication requires 90 volts minimum and closed circuit to operate. **With easyid blown fuse indication. ***Ratings for copper and aluminum wire except where otherwise noted. 6 For more information visit

7 50V Class R & H(K) Dimensional Specifications Dimensions - mm (in) A A 5-400A A For engineering drawings, go to 7

8 600V Class R & H(K) Dimensional Specifications Dimensions - mm (in) A A 5-400A A 8 For engineering drawings, go to

9 Class J Dimensional Specifications Dimensions - mm (in) A A 5-400A A For engineering drawings, go to 9

10 Broadest Range of Modular Finger-Safe Knifeblade Fuse Blocks 10 For more information visit

11 More Cooper Bussmann Fuse Blocks and Holders Modular Knifeblade Fuse Blocks with Finger-safe Covers UL, IEC & PV CH Modular Open Design Knifeblade CUBEFuse Holder IEC CH Open Design Knifeblade Class J CH In-line Class J JTN 600 Panel Mount Optima Midget & Class CC SAMI Fuse Covers Open Design Class CC & Midget Military For product data sheets, visit 11

12 Customer Assistance Customer Satisfaction Team Available to answer questions regarding Cooper Bussmann products & services Monday-Friday, 8:00 a.m. 6:00 p.m. Central Time. Contact: Toll-free phone: (855-BUSSMANN) Toll-free fax: Emergency and After-Hours Orders Next flight out or will call shipment for time-critical needs. Customers pay only standard product price, rush freight charges, & modest emergency service fee. Place these orders through the Customer Satisfaction Team during regular business hours. For after-hours, contact: After hours C 3 the Enhanced, Online Cooper Customer Center Provides real time product availability, net pricing, order status & shipment tracking across six Cooper divisions: B-Line, Bussmann, Crouse-Hinds, Lighting, Power Systems & Wiring Devices. Call for log-in assistance. Available at: Application Engineering Technical assistance is available to all customers. Application support is available Monday-Friday, 8:00 a.m. 5:00 p.m. Central Time. Contact: Toll-free phone: (855-BUSSMANN) fusetech@cooperindustries.com Online Resources Visit for the following resources: Product search & cross-reference Product & technical materials Solutions centers for information on topical issues including arc flash, selective coordination & short-circuit current rating Technical tools, like our arc flash calculator Where to purchase Cooper Bussmann product Cooper Bussmann St. Louis, MO www. cooperbussmann. com Your Authorized Cooper Bussmann Distributor is: Reorder # M Printed in USA

Power Distribution & Terminal Blocks

Power Distribution & Terminal Blocks Power Distribution & Terminal Section Contents Page Selection table for SCCR PDBs & Power terminal blocks................................ 294 Power distribution blocks Series PDBFS enclosed, with high

More information

Safe, Simple & Complete Solutions for Renewable Energy

Safe, Simple & Complete Solutions for Renewable Energy Safe, Simple & Complete Solutions for Renewable Energy SAFE. SIMPLE. COMPLETE. Optimize your renewable energy power generation capacity through the reliability and expertise of a Cooper Bussmann protected

More information

Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire

Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire 9080LBA Power Distribution Blocks Copper or Aluminum Wire Class 9080 Miniature Standard Amperage Rating - CU Wire 115 amp. 115 amp. 175 amp. 175 amp. Amperage Rating - AL Wire 90 amp. 90 amp. 135 amp.

More information

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT Are You Ready For The New SCCR Marking Requirements? What Is A Short-Circuit Current Rating (SCCR)? SCCRs on components

More information

Photovoltaic System Overcurrent Protection

Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Introduction Solar Photovoltaic (PV) systems have, over the last fifty years, evolved into a mature, sustainable and

More information

Solar Circuit Protection Application Guide. Complete and reliable solar circuit protection

Solar Circuit Protection Application Guide. Complete and reliable solar circuit protection Solar Circuit Protection Application Guide Complete and reliable solar circuit protection Introduction Benefits of Eaton s Circuit Protection Solutions Complete and Reliable Circuit Protection for Photovoltaic

More information

Reduce Downtime With Quick Access to the Right Replacement Fuse

Reduce Downtime With Quick Access to the Right Replacement Fuse Reduce Downtime With Quick Access to the Right Replacement Fuse Section Contents Page Fuse Service Kits Supplemental............................. 506-507 Branch circuit............................. 506-507

More information

Solar circuit protection application guide. Complete and reliable solar circuit protection

Solar circuit protection application guide. Complete and reliable solar circuit protection Solar circuit protection application guide Complete and reliable solar circuit protection Introduction Benefits of Eaton s circuit protection solutions Complete and reliable circuit protection for photovoltaic

More information

Terminal Blocks & Power Distribution Terminal Blocks. Make your connection

Terminal Blocks & Power Distribution Terminal Blocks. Make your connection Terminal Blocks & Power Distribution Terminal Blocks Make your connection IEC TERMINAL BLOCKS PRODUCT SPOTLIGHT Leading the industry in efficiency and productivity, the Bulletin 1492 family of IEC terminal

More information

Blocks and Holders. Ordering Information

Blocks and Holders. Ordering Information FuSE blocks OVERVIEW Description Littelfuse offers a comprehensive line of fuse blocks that incorporate many benefits such as indication, snap torelease, DIN-Rail mounting and universal mounting holes.

More information

Motor Circuit Protection Tables

Motor Circuit Protection Tables NEC Article 40 and Tables Explanation Columns & 2 Motor horsepower ratings are listed in Column. Full load amps from Tables 40.247 through 40.250 are provided in Column 2. Column Various fuse types are

More information

Datasheet. AC Outlet DIN-Rail Mountable Receptacles

Datasheet. AC Outlet DIN-Rail Mountable Receptacles Datasheet AC Outlet DIN-Rail Mountable Receptacles DIN-rail receptacles, 5A, 15A and 20A power outlets, provide a convenient power source for portable computers or test devices for in-the-panel troubleshooting.

More information

Industrial Control Power Transformers

Industrial Control Power Transformers Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

picomax The Pluggable Connection System

picomax The Pluggable Connection System picomax The Pluggable Connection System TECHNOLOGY THIS SPECIALIZED CAN T MEET ALL REQUIREMENTS. YES IT CAN. CONTENTS picomax Pin spacing: 3. mm/0.138 in;.0 mm/0.197 in; 7. mm/0.29 in Versatile Pluggable

More information

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations Solar energy is heating up Interest in renewable energy sources has

More information

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun DC disconnects for solar photovoltaic installations Connecting the power of the sun Solar energy is heating up Interest in renewable energy sources has never been greater, and the fastest growing of these

More information

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1 How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on

More information

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied

More information

gesis IP + Heavy Duty Class I, Zone 2

gesis IP + Heavy Duty Class I, Zone 2 gesis IP + Heavy Duty gesis IP+ 20i HD Z2 Heavy-Duty Connectors for Class 1, Zone 2 Hazardous Locations Catalog 2012 Catch the Next Wave in Modular Connections Plug & Go Heavy-Duty Connectors for areas

More information

AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR

AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR The AC Series C type chassis receptacles feature two connectors in the one space saving housing. A combined XLR female receptacle together with a 6.35mm (1/4 )

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits Fuses for Semiconductor Protection - Cylindrical Fuses SIBA cylindrical Ultra-Rapid fuses are available in six different sizes They can be ordered with an integral striker for blown fuse indication or

More information

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket Technical Datasheet SNK64D00 Catalogue Page SNK64S00 ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket - Ease your test operations with the built-in test sockets, - Screwdriver

More information

PRINTED CIRCUIT BOARD TERMINAL BLOCKS

PRINTED CIRCUIT BOARD TERMINAL BLOCKS Altech is pleased to announce a new, more extensive printed circuit board terminal block line. This line offers the standard single and double level fixed and pluggable terminal blocks in metric and US

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

ZS25 Screw Clamp Terminal Blocks Feed-through

ZS25 Screw Clamp Terminal Blocks Feed-through Technical Datasheet SNK668D0 Catalogue Page SNK678S0 ZS Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to mm² AWG in just mm 0.47 in spacing. SNK68V004 SNK004F0000 D CAD

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade Technical Datasheet SNK646D00 Catalogue Page SNK646S00 ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

Remote Power Panels with Breakers

Remote Power Panels with Breakers Remote Power Panels with Breakers 8 Series Panels & Enclosures N/A N/A Remote power panels with breakers are available in two different sizes, each of which may be either surfacemounted or recess-mounted,

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

Mission Critical Data Center Systems

Mission Critical Data Center Systems Mission Critical Systems Mission Critical/ Electrical Distribution Systems Data center electrical distribution designs are rapidly evolving, driven by needs such as increasing power densities, energy efficiency,

More information

Block width on rail (mm) Standard block* is shown on blue background

Block width on rail (mm) Standard block* is shown on blue background How To Read Terminal Block Specifications How To Read Carton Labels Rated wire size (mm ) Mounting on multiple rail Spacing on rail Spacing 6 mm + 0,05 (.3") M /6 Block width on rail (mm) Standard block*

More information

VLT Series 300 Watt True Sine Wave Inverter

VLT Series 300 Watt True Sine Wave Inverter VLT Series 300 Watt True Sine Wave Inverter PURE SINE WAVE INVERTER I ON 0 OFF REMOTE CONTROL AC OUTPUT POWER STATUS Vout Vin Models VLT12-300 VLT24-300 300 Watt VLT Series Inverter - 1 - TABLE OF CONTENTS

More information

Catalog January. Heavy industrial power applications Motor contactors and starters

Catalog January. Heavy industrial power applications Motor contactors and starters Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type

More information

D7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC

D7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC April 00 D Series Standard and Full Featured - Catalogue Number Structure Table -. D Series Catalogue Numbering System Family Type DPR = Standard Relay DPF = Full Featured Relay Contact Configuration =

More information

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5 AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2

More information

Switching Devices Contactors and Contactor Assemblies Special Applications

Switching Devices Contactors and Contactor Assemblies Special Applications Switching Devices Contactors and Contactor Assemblies Special Applications Price groups PG 1B, 1H /2 Introduction Contactors for special applications / SIRIUS 3RT1 contactors for resistive loads (AC-1),

More information

AC SERIES DUAL 1/4 (6.35mm) / XLR

AC SERIES DUAL 1/4 (6.35mm) / XLR AC SERIES DUAL 1/4 (6.35mm) / XLR The AC Series C type chassis receptacles feature two connectors in the one space saving housing. A combined XLR female receptacle together with a 6.35mm (1/4 ) phone jack

More information

PowerLine. Single Pole Connectors

PowerLine. Single Pole Connectors PowerLine Single Pole Connectors Ten 47 Limited Unit 2B Frances Industrial Park Kirkcaldy, Scotland, UK KY1 2XZ Tel: +44 (0)1592 655725 Fax: +44 (0)1592 651049 Email: sales@ten47.com INTRODUCTION BACKGROUND

More information

Installation Instructions for EHD, EDB, EDS, ED, EDH, EDC, FDB, FD, HFD, FDC, HFDDC Circuit Breakers and Molded Case Switches

Installation Instructions for EHD, EDB, EDS, ED, EDH, EDC, FDB, FD, HFD, FDC, HFDDC Circuit Breakers and Molded Case Switches Instruction Leaflet IL 29C101I Supersedes IL 29C101H Dated 1/11 Contents Description Page Introduction.............................. 2 Installation............................... 2 Manual Operation.........................

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

RAY-MAX Integrated Solar Power Strip

RAY-MAX Integrated Solar Power Strip RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...

More information

1756 ControlLogix Chassis Specifications

1756 ControlLogix Chassis Specifications Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC

More information

CONDUCTOR SHORT-CIRCUIT PROTECTION

CONDUCTOR SHORT-CIRCUIT PROTECTION CONDUCTOR SHORT-CIRCUIT PROTECTION Introduction: This paper analyzes the protection of wire from fault currents. It gives the specifier the necessary information regarding the short-circuit current rating

More information

Cable/Conduit Conversion

Cable/Conduit Conversion Cable/Conduit Conversion Busway can be used in many applications where cable and conduit are more commonly used. The question arises, Why use busway instead of conventional cable and conduit? Benefits

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to: PREFACE UL developed the Dead-Front Switchboard Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in understanding deadfront

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Cable Tray Selection-

Cable Tray Selection- Cable Selection- For allowable cable types see the Appendix page A-9. The following guidelines are based on the 2002 National Electrical Code, Article 392. I) Number of Multiconductor Cables rated 2000

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02. Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11

More information

LCP Coordination Panel Operations & Maintenance Manual Table of Contents

LCP Coordination Panel Operations & Maintenance Manual Table of Contents LCP Coordination Panel Operations & Maintenance Manual Table of Contents 1. Overview 2. NEC Requirements Overview 3. LCP Coordination Panel Data Sheet 4. Class CC Littelfuse CCMR Current-Limiting Fuse

More information

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection

More information

SENTRON Switching and Protection Devices Air Circuit Breakers

SENTRON Switching and Protection Devices Air Circuit Breakers Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General

More information

High Speed Fuses. High Speed Fuses

High Speed Fuses. High Speed Fuses Section Contents Page General Applications........................ 9-95 North American fuses & accessories............9-113 DFJ - High speed Class J fuse...................97 Square Body fuses & accessories............

More information

Quick Reference Guide Euro Style Terminal Blocks

Quick Reference Guide Euro Style Terminal Blocks Quick Reference Guide Euro Style terminal block connectors feature various wire termination methods including rising cage clamp, wire protector, spring, IDC and crimp snap. The design of terminal block

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

British BS 88 Fuses. Introduction

British BS 88 Fuses. Introduction British BS 88 Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 188-190 90-791-19 Accessories Indicator System & Fuse Bases 195 British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

This product can be assembled to the baseplate maintaining 5 mm center-to-center spacing. Thus any number of poles can end-to-end stack.

This product can be assembled to the baseplate maintaining 5 mm center-to-center spacing. Thus any number of poles can end-to-end stack. page 1/5 Plug-in Screw Connector System for Printed Circuit Boards 950-NLFL-DS 5.00 mm (0.197 in) Spacing - 2-12 poles PICTURES 950-NLFL-DS 950-NLFL & 971-SLK TECHNICAL INFORMATION Description This two

More information

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions Heat-Tracing Remote Monitoring Module for the NGC Control System Installation Instructions Tools Required 3 mm slotted screwdriver 3/8 hex key (for -4X only) Approvals Nonhazardous locations Type NM LISTED

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140) 9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity

More information

BETA Protecting SITOR Semiconductor Fuses

BETA Protecting SITOR Semiconductor Fuses BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

vacon 100 hvac ac drives installation manual

vacon 100 hvac ac drives installation manual vacon 100 hvac ac drives installation manual vacon 1 TABLE OF CONTENTS Document: DPD00926G Order code: DOC-INS02234+DLUK Rev. G Version release date: 25.9.13 1. Safety... 4 1.1 Danger... 4 1.2 Warnings...

More information

P System Cubicles. Certified for more safety

P System Cubicles. Certified for more safety P System Cubicles Prisma Plus LV Switchboards Certified for more safety Prisma Plus, an offer thought out for greater professionalism With the Prisma Plus P system, Schneider Electric proposes high-performance

More information

Effective July 2015 Supersedes April 2015. Reliability... 4. Selective coordination... 4. Inherent fuse reliability... 4

Effective July 2015 Supersedes April 2015. Reliability... 4. Selective coordination... 4. Inherent fuse reliability... 4 Application note 10079 Supersedes April 2015 BUSSMANN SERIES Contents Description Page Description Page Background................................ 2 Data center products........................ 6 Energy

More information

9000X AF Drives. User Manual. May 2011 Supersedes June 2009

9000X AF Drives. User Manual. May 2011 Supersedes June 2009 9000X AF Drives User Manual May 2011 Supersedes June 2009 9000X AF Drives Disclaimer of Warranties and Limitation of Liability The information, recommendations, descriptions, and safety notations in this

More information

IEC and British Standard Fuses

IEC and British Standard Fuses IEC and British Standard Fuses Section Contents Page Application Data...7-8 CSA Type P and Type D fuses (CDS, CDN & PON)............................9 Tron HRC Form II Class C fuses (CGL Form II Class C)..........................

More information

Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance

Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance Owner s Manual For Automatic Transfer Switch 100-200 Amp, Service Entrance/Non-Service Entrance Model Numbers RTST100A3 RTSP100A3 RTST150A3 RTST200A3 RTSP200A3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

More information

08. SEK IDC CONNECTORS

08. SEK IDC CONNECTORS . IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these

More information

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions

More information

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases. G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

PREFACE. The products covered by this Guide are:

PREFACE. The products covered by this Guide are: PREFACE UL has developed the Molded-Case Circuit Breaker (MCCB) Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in

More information

FAQs-Main switchboard design criteria

FAQs-Main switchboard design criteria FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety

Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety Arbiter Systems, Inc. test equipment offers outstanding performance, flexibility, and value. Our test leads offer nothing less.

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

Motor Protection Voltage Unbalance and Single-Phasing

Motor Protection Voltage Unbalance and Single-Phasing Motor Protection Voltage Unbalance and Single-Phasing Cooper Bussmann contributes the following information, which is an excerpt from their 190-page handbook SPD Selecting Protective Devices Based on the

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Trapezoidal-Connectors Series TMC

Trapezoidal-Connectors Series TMC Trapezoidal-Connectors Series TMC Subminiature-D Connectors to DIN 41 652/IEC 807-3 General Series TMC connectors are available in 5 different housing sizes with 9, 15, 25, 37 and 50 pins. In applications

More information

POLARIS INSUL-TAP CONNECTORS FOR TWO WIRES & IN-LINE SPLICERS/REDUCERS

POLARIS INSUL-TAP CONNECTORS FOR TWO WIRES & IN-LINE SPLICERS/REDUCERS INSUL-TAP CONNECTORS FOR TWO S & IN-LINE SPLICERS/REDUCERS IT SERIES 1 2 3 4 Insul-Tap connectors are suitable for connecting two wires. For sizes 3/0 AWG and smaller, they are available in two styles

More information